27
Installation and Operation Guide for Density Series System Cubix Corporate Headquarters 2800 Lockheed Way, Carson City, Nevada 89706-0719 Tel (775) 888-1000 Fax (775) 888-1001 Customer Service (800) 829-0551 European Headquarters One Hunter Road, Kirkton South, Livingston, EH54 9DH, Scotland Tel 01506 465065 Fax 01506 465430 International + 44 1506 465065 Customer Service 0800 591 887 Cubix Web Site: http://www.cubix.com

Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

Installation and Operation Guidefor

Density Series System

Cubix Corporate Headquarters ● 2800 Lockheed Way, Carson City, Nevada 89706-0719 Tel (775) 888-1000 ● Fax (775) 888-1001 ● Customer Service (800) 829-0551

European Headquarters ● One Hunter Road, Kirkton South, Livingston, EH54 9DH, ScotlandTel 01506 465065 ● Fax 01506 465430

International + 44 1506 465065 ● Customer Service 0800 591 887

Cubix Web Site: http://www.cubix.com

Page 2: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

NOTICE

Cubix Corporation reserves the right to revise this documentation and to change content fromtime to time without obligation on the part of Cubix Corporation to provide notification of such revision or change. Additionally, Cubix Corporation assumes no responsibility for its use and provides this documentation without warranty of any kind, either implied or expressed. CubixCorporation may make improvements or changes in the product(s) and/or program(s) described in this documentation at any time.

All product names mentioned in this document are trademarks or registered trademarks of theirrespective owners.

Mention of third-party products is for informational purposes only and is not to be considered anendorsement or recommendation. Cubix Corporation assumes no responsibility for the performance of these products.

Copyright © 1999 by Cubix CorporationAll Rights Reserved

Printed in U.S.A.DOC #0865

Page 3: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

Table of Contents

Chapter 1 - Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

Overview of Density Series System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3

Passive Backplane Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4

Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Chapter 2 - Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Unpacking the Density System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Installation of a Density System into Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

VKM (Video, Keyboard and Mouse)-External Cabling . . . . . . . . . . . . . . . . . . . . . . . . . .6-7

Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Warnings Pertaining to Internal Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Mux Option Switch (S1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-10

Integrating Density Series into a GlobalVision Management System . . . . . .10

Configuring IES Data Highway Addresses . . . . . . . . . . . . . . . . . . . . .10-11

IES Data Highway Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Data Highway Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-13

Installing Additional Server Boards (DP or SP Series) . . . . . . . . . . . . . .13-14

Installing/Replacing Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

Chapter 3 - Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Front Console Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

VKM and CD LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Group Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Reset Selected Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-17

Power On/Off Selected Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

CD-ROM Select/Deselect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Select Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

Console Key Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

Page 4: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

Appendix A - Agency Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19-21

Appendix B - Customer Service Information . . . . . . . . . . . . . . . . . . . . . . . . . .22-23

List of Figures

Figure 1 Density Series System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

Figure 2 Density Series System - Front View (front cover removed) . . . . . . . . . . . . . . . .2

Figure 3 Density Series Chassis - Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Figure 4 Multiplexor/IES Board Layout (Assembly 400-A06191) . . . . . . . . . . . . . . . . . . .3

Figure 5 4x DP Density Series Backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Figure 6 8x2 SP Density Single-Processor Backplane . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Figure 7 2x DP+4x SP Density Series Backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Figure 8 Connecting the VKM Modules & Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Figure 9 Inserting Server Board into Chassis Group Slot . . . . . . . . . . . . . . . . . . . . . . . .13

Figure 10 Density Front Console Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . .15

Figure 11 Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Figure 12 VKM and CD LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Figure 13 Group Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Figure 14 Reset Selected Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Figure 15 Power On/Off Selected Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Figure 16 CD-ROM Select/Deselect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Figure 17 Select Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

Figure 18 Console Key Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

List of Tables

Table 1 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Table 2 Mux Option Switch Definitions (S1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-10

Table 3 Factory Default Settings for Switch 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Table 4 IES Address Switch Configuration (S2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Page 5: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

1

Figure 1 Density Series System

Chapter 1 - Introduction

The Cubix Density enclosure houses multiple server-class Intel compatible computersneatly and efficiently in a single, rack-mountable drawer. The Density Series can support both single and dual SMP processor boards through three standard backplaneoptions*:

● Four dual-SMP processor boards (DP Series) ● Eight single-processor processor boards (SP Series)● Two dual-SMP ( D P Series) plus 4 single-processor boards

*Other backplane options are available. Consult your sales representative for more i n f o r m a t i o n .

Overview of Density Series System

The Density Series system is designed for the purpose of computer consolidation.Cubix equipment solves the problems associated with space-constrained backroomcomputing centers. Figures 2 and 3 on the following page show the arrangement of aconsolidated Density system.

Page 6: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

Group 4 IES

on

Group 3 Group 2 Group 1

Intelligent EnvironmentalSensor/MUX Module

Three Hot-SwappablePower Supplies in aFault-Tolerant n+1

Configuration

Two Out-of-band Data Highway

Connectors

SystemPowerOn/Off

PowerSupplyOn/Off

Switches

CoverPlate forIES DataHighwayAdapter

Power CordRecepticle

VKM Daisy-Chain Connectors

IES Termination Switch

Figure 3 Density Series Chassis - Rear View

2

Unlocked

Locked

Selected

SelectChassis

ResetSelected Group

VKM CDGroup 1

Group 2

Group 3

Group 4

CD-ROMSelect/Deselect

GroupSelect

STATUSPower Fans Temp

Power On/OffSelected Group

Figure 2 Density Series System - Front View (front cover removed)

12.25”(30.63 cm)

Shared Floppy Drive

Front-Removable Hard Drives

Six Cooling Fans(3 Front, 3 Rear)

Reset Selected Group

Power On/OffSelected Group

Selected Group & CD-ROM

Status Lights

Power/Fans/TemperatureStatus Lights

Group Select

CD-ROMSelect/Deselect

Console KeyLock/Unlock

Select Chassis SharedCD-ROM Drive

19” (47.5 cm)

Page 7: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

3

The Intelligent Environmental Sensor (IES) is integrated into a Multiplexor/IES Moduleboard which is installed in a backplane slot (IES slot, Figure 3) of the Density Seriessystem. The IES monitors system and processor health, and functions as an interfacebetween the Density Series system and the Cubix IES Supervisory System. The IESSupervisory System provides SNMP instrumentation and integration with the CubixGlobalVision management application.

Figure 4 Multiplexor/IES Board Layout (Assembly 400-A06191)

IES Termination Switch

IES Mux Module

IES Address Switch

Mux Option SwitchMultiplexor Power

MultiplexedVideo/Keyboard/MouseConnectors

Jumpers JP2through JP9 toDisable VKM

IES JacksJ5

P1

P2

S3

S4S1 S2J2J1

LS1

JP1 J4J3

Passive Backplane Options

The Density Series enclosure is assembled in one of the following passive backplaneconfigurations:

4X DP (Figure 5)● Supports up to 4 Cubix DP model dual-SMP servers.● One shared ISA/PCI expansion slot is provided for each group.

8X SP (Figure 6)● Supports up to 8 Cubix SP model single-processor servers.● One ISA/PCI expansion slot is provided for each group.● Some SP boards require more space than is standard within a single group and

will limit the number of processors within a system.

2X DP + 4X SP (Figure 7)● Supports 2 Cubix DP model dual-SMP servers and up to four Cubix SP model

single-processor servers.● One ISA/PCI expansion slot is provided for each group.● A Cubix SP model single-processor server can be installed in the DP model

dual-SMP server group. ● Some SP boards require more space than is standard within a single group and

will limit the number of processors within a system.

Page 8: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

4

Figure 5 4x DPDensity Series Backplane

Figure 6 8x2 SP Density Series Single-Processor Backplane

Figure 7 2x DP+4x SPDensity Series Backplane

Group 1 Group 2 Group 3 Group 4

Group 1 Group 2 Group 3 Group 4 Group 5 Group 6 Group 7 Group 8

Group 1 Group 2 Group 3 Group 4 Group 5 Group 6

Page 9: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

5

Table 1 Density Series System Technical Specifications

System Architecture x86 multiserver class managed systems.

Hard-Disk-Drives Up to 12 third-height, vertically mounted drives mounted in single, dual or triple drive-mounting assemblies.

Floppy Drive One shared third-height, 3.5" vertically mounted, 1.44MByte capacity floppy disk drive.

CD-ROM Drive One shared and independently switched CD-ROM drive.

Dimensions RETMA-compatible rackmount enclosure - 19" wide x 12.25"high (7U) x 23.25" deep. Faceplate 17" wide x 12.25" high.

Integrated Multiplexor Shared support for: VGA Video, PS/2-compatible keyboard, PS/2-compatible mouse, Floppy drive, CD-ROM drive, Environmental monitoring, and Server status monitoring.

Front-Panel Controls Key lock multiplexor/video enable/disable, Group processor reset, Group power on/off, Group select, CD-ROM select and Select Chassis.

Front-Panel Status Power/Fan/TemperatureDisplays Selected Group for Video/Keyboard/Mouse control

Selected Group for CD assignment"Selected" LED for Chassis activation

Power Supply Three redundant, load-sharing (n+1) power supplies per systemHot-swappable (minimum 2 power supplies required tosupport system operation)Power on indicatorInput power 12.0A@ 120VAC

7.0A@ 240VACPower Ratings

System Power RatingMaximum Total Power 600W Maximum Peak Power 738WVolts Amps Max/Peak Power Max/Peak+5VDC 90A/90A 450W/450W+12VDC 13A/20A* 156W/240W*-12VDC 4A/4A 48W/48W* + 12V @ 20Amps for 10 seconds maximum.

If sustained longer, the system will over-current trip.

Operating Environment 0 - 40° C temperature 5% - 80% noncondensing humidity

Warranty 3-year warranty with registration (parts and labor, return to manufacturer)

Technical Specifications

Page 10: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

Chapter 2 - Installation

Unpacking the Density System

1. Inspect the shipping box for damage.

2. Remove the Density Series system from the shipping container, and place on a secure working surface.

Installation of a Density System into a Cabinet

The Density Series system is a rack-mount enclosure designed to be installed in aCubix System 1010 cabinet or other RETMA-compatible 19" wide equipment rack.

1. Remove the middle and rear sliding rails from the sides of the Density System.

2. With the middle rails still inserted into the rear rails, mount them into the cabinet using the four brackets provided.

VKM (Video, Keyboard and Mouse)-External Cabling

These devices may be shared between multiple systems. This is accomplished bydaisy-chaining the systems together with DB-25 male to male cables attached to theVKM connectors which are located on the back of the Mux/IES board (see Figure 8). Amaximum number of eight Density chassis may be VKM connected.

6

WARNING!Care should be taken when installing a Density Series system. Theweight of a fully loaded Density Series enclosure (approx. 130 lbs.)placed on fully extended rails may cause the cabinet to tip forward.The cabinet should be secured before installing the enclosure.

Page 11: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

Connect the unused VKM connector onthe first system to the Video/Keyboard/Mouse Breakout Module, using DB-25cabling. (VKM Module can be mounted inthe top of the System 1010 cabinet orwherever it is convenient.)

If the monitor, keyboard, and mouse arenot already connected to the breakoutmodule, route the cables for these devicesinto the cabinet via the access hole in thetop cover and connect the cables to thebreakout module.

Connect the video terminator plug to theunused VKM connectors on the last system.

7

Figure 8 Connecting the VKM Module & Cables

VKM Connectors onMux/IES Board

System 1

VKM Connectors onMux/IES Board

System 2

VKM Connectors onMux/IES Board

System 3

Video Terminator Plug

DB-25 Cable

VKM Breakout Module (enlarged view)

MouseVideoKeyboard

Note: JP2 through JP9 are available for customers who wish to disable VKM for selected groups (see Figure 4) and use their own external VKM. For more informationcontact Customer Service.

Input Power

The Density Series systems uses three power supplies operating in parallel. Two of thethree are required to power the system. Therefore if any one of the three fail, systemintegrity is maintained. Input power is provided via a single power cord shipped withyour system.

The following type of power cord is supplied:(Domestic 120Vac) = SVT,SJT 125V/13A AWG16/3(European 240Vac) = SVT,SJT 250V/10A 1mm2/3

Page 12: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

Warnings Pertaining to Internal Access

The following Sections require access to the Density CPU bay and power supply areaswhich are restricted to service personnel only. Therefore, these warnings apply to eachsection.

8

CAUTION!C O N TAINS HAZARDOUS VOLTA G E S ,NO USER SERVICEABLE PARTS INSIDE

ATTENTION!TENSION DANGEREUSE, L’APPAREIL NE COMPORTE AUUN

ELEMENT QUE L’UTILISATEUR PULSSE REPARER

ACHTUNG!GEFAHRLICHE STROMSPANNUNGEN!

KEIN BENUTZER ZUGANGLICHE TEILE!

Mux Option Switch (S1)

Mux options determine the behavior of the Density system when the console is locked.The options are set with an 8 position DIP switch (S1) on the Multiplexor/ IES board(see Figure 4 for the switch location). Changing the following Mux option switches must be followed by a power-on sequence of the Density chassis. Positions 1 through 4 are Mux option selections. Positions 5 through 8 should not change, but remain consistent with Table 3, factory default settings.

Video Only - If this option is enabled and the console is locked, all of themuxed devices except for the monitor are disabled. The monitor remains functional on the channel that was selected at the time the lock occurred.

This is a useful feature if there is a management application running on one of the computers in the system. By selecting the processor group containingthis computer before locking the console, the screen on the managementapplication can be monitored. However, the other muxed devices and the console functions remain disabled, thus eliminating the possibility of unauthorized intervention.

off on on on

Table 2 Mux Option Switch Definitions (S1)

Option 1 2 3 4

Page 13: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

Table 2 Mux Option Switch Definitions (S1) (cont.)

Option

Monitor/Keyboard/Mouse/Reset - If this option is enabled and the consoleis locked, the only muxed device that will be disabled is the floppy diskdrive. The monitor, keyboard, and mouse will continue to function on theselected channel.

In addition, the "Reset Selected Group" pushbutton on the front panel of thesystem will remain functional, allowing an operator to reset the computerselected as the current group at the time the console is locked.

The "Group Select" pushbuttons are disabled, thus preventing the operatorfrom resetting another processor group.

This is a useful feature if the system administrator wants to prevent use ofthe floppy drive for security purposes.

Floppy Channel 1 - If this option is enabled and either the console islocked or the system is disabled, the floppy drive will be connected to thefirst mux channel, regardless of the processor group currently selected.

Master Console Key lock - Systems may be connected by daisy-chainingthem via the VKM connectors on the rear panel of the Multiplexor/IESboard. This connection is required to share a m o n i t o r, keyboard, and mousebetween as many as eight systems.

If the Master Console Key lock option is enabled, the system will functionas a "master console." If the master console is locked, the consoles of all systems connected to the master console are locked, regardless of theposition of the key switch on their front panels.

A Density Series system will not function as a master console if the systemis turned off.

A Density Series system with the Master Console Key lock option enabledwill remain the master console through a power failure.

More than one system in a daisy-chain can have the Master Console Keylock option enabled. If this is the case, it is necessary to unlock the keyswitch on the front panel of each system with the option enabled. As longas the key switch remains in the locked position on any system with themaster key lock option enabled, all of the systems in the daisy-chain willremain locked.

9

on off on on

on on off on

on on on off

1 2 3 4

Page 14: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

10

1 2 3 4 5 6 7 8

S1 ON ON ON ON ON ON OFF OFF

Table 3 Factory Default Settings for Switch 1

Integrating Density Series into a GlobalVision Management System

The Density Series system may be managed by an existing GlobalVision (version 2.15or greater) management system operating in a Cubix ERS/FT II or PowerSMP serieschassis. The following section will provide the configuration necessary to integrate theDensity system into the existing management system.

Configuring IES Data Highway Address

The Density Series system includes an out-of-band Data Highway which connects thechassis Intelligent Environmental Sensor (IES) to a GlobalVision management processor (refer to the GlobalVision Management System User’s Guide). This datahighway can be daisy-chained between systems to allow management of up to 31enclosures from a single GlobalVision management processor.

Each chassis connected to the IES data highway must be assigned a unique data highway address. The GlobalVision console application uses this address to identifyand communicate with each IES module. Valid IES addresses range from 1 to 31. The factory default address of the IES is 1.

The Density Series IES Data Highway is integrated onto the Mux/IES board. Theaddress of the IES is determined by an 8-position DIP switch (S2) located on the topedge of the board (see Figure 4 for switch location). Each chassis that is added isassigned the next address number in the sequence. S2 must be set accordingly. Notwo chassis can have the same address.

Table 4 contains valid IES address switch configurations for 31 chassis.

on on on onNo Mux Options Enabled - The option switches override one or more of theeffects of locking the console using the console Mux. The console Mux isexplained in Chapter 3 of this manual. If none of the key lock options areenabled, locking the console disables the following functions:

● Group selection pushbuttons (this prevents the operator from changing mux channels)

● Group Power pushbuttons.● BC Reset pushbutton. ● Muxed device connections (monitor, keyboard, mouse, and floppy drive)

are disabled.

Table 2 Mux Option Switch Definitions (S1) (cont.)

Option 1 2 3 4

Page 15: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

11

DIP Switch Position

Address 1 2 3 4 5 6* 7* 8**Factory Default Select“ O n ”-DO NOTC H A N G E

1 OFF ON ON ON ON * * *2 ON OFF ON ON ON * * *3 OFF OFF ON ON ON * * *4 ON ON OFF ON ON * * *5 OFF ON OFF ON ON * * *6 ON OFF OFF ON ON * * *7 OFF OFF OFF ON ON * * *8 ON ON ON OFF ON * * *9 OFF ON ON OFF ON * * *

10 ON OFF ON OFF ON * * *11 OFF OFF ON OFF ON * * *12 ON ON OFF OFF ON * * *13 OFF ON OFF OFF ON * * *14 ON OFF OFF OFF ON * * *15 OFF OFF OFF OFF ON * * *16 ON ON ON ON OFF * * *17 OFF ON ON ON OFF * * *18 ON OFF ON ON OFF * * *19 OFF OFF ON ON OFF * * *20 ON ON OFF ON OFF * * *21 OFF ON OFF ON OFF * * *22 ON OFF OFF ON OFF * * *23 OFF OFF OFF ON OFF * * *24 ON ON ON OFF OFF * * *25 OFF ON ON OFF OFF * * *26 ON OFF ON OFF OFF * * *27 OFF OFF ON OFF OFF * * *28 ON ON OFF OFF OFF * * *29 OFF ON OFF OFF OFF * * *30 ON OFF OFF OFF OFF * * *31 OFF OFF OFF OFF OFF * * *

Table 4 IES Address Switch Configuration (S2)

Page 16: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

12

1. Connect one end of the data highway cable to either of the Out-of-Band DataHighway Connections found on the Mux/IES board (see Figure 3).

2. If this system is not the last device in the chain, connect the other Out-of-BandData Highway Connection to the next device. Set switch S3 (see Figure 4 forswitch location) to the OFF position. The switch is OFF when it is pointing to theleft when viewed from the rear of the Density Series system.

3. If this system is the last device in the chain, terminate the highway by settingswitch S3 to the ON position. The switch is ON when it is pointing to the rightwhen viewed from the rear of the Density system.

Data Highway Adapter

Density Series servers may optionally be used as the GlobalVision Console for a groupof Cubix enclosures. The server which will act as the GlobalVision Console requiresinstallation of a Data Highway Adapter to the COM2 header. This adapter provides an interface point for the GlobalVision console processor to collect IES data from all chassis in the data highway chain.

Perform the following instructions to install a data highway adapter on a Density Seriess e r v e r.

1. Remove the cover plate for IES Data Highway Adapter located in the rear of the DP Density chassis. (See Figure 3. Location may vary on other chassis.)

2. Attach the 10-pin ribbon cable of the Data Highway Adapter to the COM2 header:

● SP boards - on the top edge of the board.● DP boards - the jack is located along the top edge of the board.

NOTE!While similar to an RJ-11 telephone station cable, the datahighway cable is wired as a "straight through" cable and cannotbe replaced using a standard telephone cable. The cable will havea white sticker marked "Cubix IES Module Only."

IES Data Highway Cable

After setting the IES address, connect the Density Series system to the Cubix data highway.

Page 17: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

1. At the front console, select and turn power off to the group location where youintend to install the server board (refer to Chapter 3 for front console operationinstructions).

2. If a hard-drive is installed in the group hard drive slot, remove the hard drive andthe SP or DP board.

3. Configure the switch and jumper settings on the board being installed. (Refer tothe Quick Reference Guide accompanying the board.)

4. Insert the board into the group slot ensuring the card interface tabs are alignedwith the center of the slot.

5. Seat the processor card into its slot by firmly pressing on the top of the card withthe palm of your hand.

6. Install the hard drive assemblyinto the appropriate hard drivebay located in the front of theDensity closure (Figure 2).The hard drive assembly will fitinto the hard drive interface ofthe I/O board. Make sure it isseated.

7. At the front console applypower to the processor group.

Figure 9 Inserting Server Board into Chassis Group Slot

13

CAUTION!Group power must be off before installing any Cubix processors,peripheral boards, or third-party peripheral cards. Failure to followthis warning may result in damage to the Density Series system and boards being installed.

3. Secure the Data Highway Adapter board in the cut out area. (The Data Highway Adapter assembly consists of one A4212 board, ribbon cable, two brackets and two screws.)

Installing Additional Server Boards (DP or SP Series)

The following instructions provide general installation instructions for Density Seriescompatible server boards. Refer to the appropriate manual supplied with the processorboard for detailed configuration instructions.

Page 18: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

14

Installing/Replacing Power Supply

Density Series uses three hot-swappable load-sharing Power Supplies in a redundantfault-tolerant n+1 configuration. Redundant cooling systems provide added resilience.

The steps for replacing a Power Supply are quite simple. Refer to Figure 3 for locationof Power Supplies.

1. The power supply that does not have the green light on is the power supply that needs replacement.

2. Turn the switch to an “off” position on the Power Supply to be removed.3. Loosen the two captive screws and grasp the Power Supply handle. Pull the

Power Supply out of the chassis.4. Insert the replacement Power Supply.5. Secure the captive screws.6. Turn the new Power Supply “on”.

CAUTION!The Density System requires two power supplies to provide powerto server groups. Make certain there are two Power Supplyswitches “on” before removing the third Power Supply.

Page 19: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

Status LEDs- Display Diagnostic information

Power - Green indicates that the power supplies are functioning properly. Red indicatesa failure of one of the power supplies, or power supply fans. To find the faulty powersupply, additional LEDs are located on each power supply.

Fans - Green indicates that the system fans (in the front, below the disk drives) areoperating correctly. Red indicates a system fan failure.

Temperature - Green indicates system temperature is withinacceptable operating parameters. Red indicates system temperature has exceeded acceptable operating parameters.

15

Chapter 3 - Operation

Front Console Controls

The front console controls of the Density Series system provide access to all processorselection and system alarm indicators. Additionally, the front console provides the ability to reset individual groups without having to open the enclosure. "Group" refers toa group of slots on the backplane that are connected together and contain a SP or DPSeries plug-in computer, thus comprising one computer in the system. The panel shownbelow is for 8 groups. Your panel may be slightly different.

Unlocked

Locked

Selected

SelectChassis

ResetSelected Group

VKM CDGroup 1

Group 2

Group 3

Group 4

VKM CDGroup 5

Group 6

Group 7

Group 8

CD-ROMSelect/DeselectSTATUS

Power Fans Temp

Power On/OffSelected Group

GroupSelect

Figure 10 SPDensity Front Console Controls and Indicators

STATUSPower Fans Temp

Figure 11 Status LEDs

Page 20: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

16

VKM and CD LEDs - Displays Group and CD-ROM selection information

VKM LEDs display the group that is currently selected for output to the video, keyboard,mouse, and floppy disk drive. The LEDs alsoindicate the power status of the selected group.Green indicates power on, red indicates poweroff.

The CD LEDs display which group is currentlyselected for connection to the internal CD-ROMdrive. The green LED will display on the groupwhere the CD-ROM drive is assigned.

Figure 12 shows group 1 selected for VKM output, and the internal CD-ROM connectedto the processor board in group 6.

Group Select - Selects another group

The operator may use the Group Select pushbutton on the frontpanel to choose which group will control the output to the VKM. Thegroup selected will be displayed under the VKM LED columns. TheLED will be green if the power to the group is on, red if the power isoff.

When a group is selected, its channel on the multiplexor is enabled,thus connecting the selected group to the monitor, keyboard, mouse,

and floppy drive. Several of the other front panel operations apply only to the selectedgroup.

The Group Select pushbutton is disabled if the console is locked.

Reset Selected Group

The Reset Selected Group pushbutton is used to select a new group. This pushbuttonis recessed to prevent accidental resets. To reset a group depress the Reset SelectedGroup button using a pointed object (such as a pen) to push the button. Next, use theGroup Select button to choose the new group. The VKM LEDs will indicate which groupis selected.

GroupSelect

VKM CDGroup 1

Group 2

Group 3

Group 4

VKM CDGroup 5

Group 6

Group 7

Group 8

Figure 12 VKM and CD LEDs

Figure 13 Group Select

Page 21: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

17

The Reset Selected Group pushbutton is operational only ifthe chassis is selected (selected group LED is on) and theconsole is unlocked.

Power On/Off Selected Group

The power to individual groups may be turned on or off via thePower On/Off Selected Group pushbutton. The pushbutton is recessed to prevent a group from being unintentionally powered on or off.

Use the Group Select button to select the group to power on or off. The VKM LEDs willindicate which group is selected. Use a pointed device (such as a pen) to press thepushbutton. The pushbutton functions as a toggle, turning power on if it is already off orturning power off if it is already on. The VKM LED for the selected group will indicatethe power status; green if power is on, red if power is off.

Pressing the Power On/Off Selected Group pushbutton applies power to or removespower from the selected group only. Other groups in the system are not affected.

CD-ROM Select/Deselect - Assigns the CD-ROM drive to a group

The CD-ROM Select/Deselect pushbutton allows you to assignthe CD-ROM drive to an individual group.

Use the Group Select button to select the group (the VKM LEDswill indicate which group is selected). When the proper group isselected, push the recessed pushbutton to assign the drive to thatgroup.

The CD LED will now be on (green) indicating that the CD-ROM drive is now assignedto that group.

Note: The operating system for the selected group must have the proper CD-ROM drivers installed, and MUST be rebooted before it will see the attached CD-ROM drive.

Power On/OffSelected Group

CD-ROMSelect/Deselect

Figure 15 Power On/Off Select

Figure 16 CD-ROM Select

ResetSelected Group

Figure 14 Reset Selected Group

Page 22: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

18

Select Chassis

The monitor, keyboard, and mouse may be shared by all systems installed in a singleCubix cabinet .

The Select Chassis pushbutton determines which systemis enabled or disabled to control these devices. Only onesystem may be selected at a time.

When a system is enabled, the muxed devices are underits control. In addition, the group reset and power on/offfunctions are operational, allowing a group to be reset or powered on or off via buttons on the console. The LEDlabeled "Selected" is illuminated when a system is selected.

When a system is disabled, the muxed devices are not available to the system and thegroup reset and power functions are not operational. Note that a disabled system canaccess none of the muxed devices, including the floppy drive (to override this featurerefer to the Mux Option Configuration, Table 2).

Note that a system is also automatically disabled when another system that is sharingthe muxed devices is enabled.

Console Key Lock

A Console Key Lock resides on the front panel (Figure 18).When locked, it disables video, keyboard and mouse controlbased on the Mux Option Switch settings (Table 2).

Selected

SelectChassis

Unlocked

Locked

Figure 18 Console Key Lock

Figure 17 Select Chassis

Page 23: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

19

Appendix A

Page 24: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

20

FCC PART 15

NOTE: This equipment has been tested and found to comply with thelimits for a Class A digital device pursuant to Part 15 of FCC Rules.These limits are designed to provide reasonable protection againstharmful interference when this equipment is operated in a commercialenvironment. This equipment generates, uses, and can radiate radiofrequency energy and, if not installed and used in accordance with theinstruction manual, may cause harmful interference to radiocommunications. Operation of this equipment in a residential area islikely to cause harmful interference, in which case the user will berequired to correct the interference at his/her own expense.

Class A Device

"This digital apparatus does not exceed the Class A limits for radio noiseemissions from digital apparatus set out in the Radio InterferenceRegulations of the Canadian Department of Communications."

"Le présent appareil numerique n‘ émet pas de bruits radioélectriquesdépassant les limites applicables aux appareils numériques de la classA prescrites dans le Règlement sur le brouillage radioélectrique édictépar le ministère des Communications du Canada."

WARNING: EN55022 CLASS A

This is a Class A product. In a domestic environment this product maycause radio interference in which case the user may be required to takeadequate measures.

Agency Approvals

Page 25: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

Declaration of Conformity

We,

Cubix Corporation2800 Lockheed WayCarson City, NV 89706-0719 U.S.A.

declare under our sole responsibility that the product:

Density Series System

to which this declaration relates is in conformity with the following standards:

Safety: EN60950: IEC 950 (1991) 2nd Ed.Amendment No. 1 (1991)Amendment No. 2 (1993)Amendment No. 3 (1995)Amendment No. 4 (1996)

EMC: Emissions: EN55022 Class AImmunity: EN50082-1 (1992)

following the provisions of:

Low Voltage Directive 73/23/EECElectromagnetic Compatibility Directive 89/336/EEC

James M. Goldenberg, Director Research & Development

Carson City, NV USA - August 10, 1998

21

Page 26: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

Appendix B

22

Page 27: Installation and Operation Guide for Density Series Systemcubix.com/support/product/chassis/density_common/density-manual.pdf · Installation and Operation Guide for Density Series

23

Customer Service Information

For Customer Service Information: (800) 829-0551

Customer Service available from 5:00 am to 5:00 pm PST Monday through FridayAlso, from 8:00 am to 4:00 pm PST on SaturdayClosed holidays and holiday weekends

Customer Service Web site: http://www.cubix.com/support

Customer Service Email address: [email protected]

Use the Cubix Web site for trouble-shooting aids and for access to the latest information on Cubix products.