43
ROI-S06554-051E 071116 P ASOLINK N ETWORK M ANAGEMENT T ERMINAL PNMT (Java version) Installation Manual (WindowsXP) NEC Corporation Copyright © 2007

Install PNMT(WinXP)

Embed Size (px)

Citation preview

ROI-S06554-051E 071116

P ASOLINK

N ETWORK

M ANAGEMENT

T ERMINAL

PNMT (Java version)Installation Manual

(WindowsXP)

NEC CorporationCopyright © 2007

ROI-S06554

- i -

Table of Contents

1. Installation Sequence ........................................................................................................ 1

2. Phone and Modem Options Setting (Standard 19.2Kbps Connection) ........................ 2

3. Installation of USB Com Port Driver (USB Connection) .............................................. 7

4. Dial-up Setting ................................................................................................................. 10

5. SNMP Service Setting ..................................................................................................... 21

6. PNMT Setup .................................................................................................................... 26

7. Network Connections Setting on Windows XP ............................................................ 31

8. Launching PNMT............................................................................................................ 40

ROI-S06554

- 1 -

1. Installation Sequence

Only Administrator group privilege level users are authorized to configure the following settings,

(1) Dial-up Connection

(2) Ethernet Connection

Standard 19200bps Modem Setting

(Phone and Modem Options Setting)

USB Modem Setting

(Installation of USB Com Port Driver)

Network Element (NE) other than

PASOLINK NEO PASOLINK NEO ONLY

Step 2: Dial-up Connection Setting

Step 3: SNMP Service Setting

Step 4: Pasolink Network Management Terminal (PNMT) Setup

Step 5: Launching PNMT

Step 1: Modem Setting

Step 2:Network Connections Setting

Step 3: Launching PNMT

Step 1: Pasolink Network Management Terminal (PNMT) Setup

ROI-S06554

- 2 -

2. Phone and Modem Options Setting (Standard 19.2Kbps Connection)

This section deals with the use of a Standard 19.2Kbps Modem Dial-up connection. (for non-PASOLINK-NEO network elements). If you wish to use a USB Modem Driver (for PASOLINK-NEO network elements, please refer to 3.”Installation of USB Com Port Driver”, p.7

(1) Click Start | Settings | Control Panel.

(2) Click the Phone and Modem Options icon in the Control Panel window to start configuring the modem.

ROI-S06554

- 3 -

(3) Enter your country and area code in the Location Information window. Click [OK].

(4) Verify the Location and Area Code.

ROI-S06554

- 4 -

(5) Select the Modem tab. Click [Add] to continue with adding the new modem for the PNMT.

(6) Check Don’t detect my modem ... and click [Next] to continue.

ROI-S06554

- 5 -

(7) Select Standard Modem Types from the list of Manufacturers and Standard 19200bps Modem from the Models. Click [Next] to continue.

(8) Select Selected ports and COM#, then click [Next] to continue.

ROI-S06554

- 6 -

(9) Click [Finish] to complete the new modem installation.

(10) Verify that Standard 19200 bps Modem and COM1 are displayed. Click [OK].

(11) Please proceed directly to section 4. Dial-up Setting.

ROI-S06554

- 7 -

3. Installation of USB Com Port Driver (USB Connection)

This section describes the installation of a USB Modem Driver (for PASOLINK-NEO network elements) as the dial-up connection.

Connect the PNMT computer to the LCT Port of the NE with a standard USB cable.

(1) Select No, not this time and Click [Next].

(2) Select Install from a list or specific location [Advanced] and click on [Next].

ROI-S06554

- 8 -

(3) Insert the USB driver CD-ROM in the computer’s disk drive and select Search for the best driver in these locations and check Search removable media [floppy, CD-ROM ...] then, click [Next].

(4) Click [Continue Anyway] in the Hardware Installation pop-up alert.

ROI-S06554

- 9 -

(5) USB Modem Driver Installation starts.

(6) USB Com Port Driver installation is complete.

ROI-S06554

- 10 -

4. Dial-up Setting

(1) Click Start | Settings | Control Panel and the Network Connections icon to start configuring the Dialup setting.

(2) The Network Connections window appears. Click Create a new connection in the Network Tasks area.

ROI-S06554

- 11 -

(3) The Welcome to the New Connection Wizard window appears. Click [Next].

(4) Select Connect to the network at my workplace and click [Next] to continue.

ROI-S06554

- 12 -

(5) Select Dial-up connection and click [Next] to continue.

(6) Select Modem - Choose a connected port, and click [Next] to continue.

NOTE

This screen appears only when a USB Modem Driver has been installed.

In case of connecting with RS232C-Check Modem-Standard 9600bps Modem[COM1].

ROI-S06554

- 13 -

In case of connecting with USB-Check Modem-USB Modem Driver [COM3].

(7) In the New Connection Wizard window, input connection name into Company Name field.

Click [Next].

In case of connecting with RS232C-Type [PNMT(RS232C)]

ROI-S06554

- 14 -

In case of connecting with USB-Type [PNMT(USB)]

(8) Enter any number in the Phone number field and click [Next] to continue.

ROI-S06554

- 15 -

(9) You can also create a shortcut on your desktop if desired. Click [Finish].

RS232C connection

USB connection

ROI-S06554

- 16 -

(10) In the Connect Dial-up Connection window, click [Cancel] to continue. Click Properties in the Connect Dial-up Connection window.

(11) In the Properties Window click on the General tab. Click [Configure].

RS232C setting

USB setting

ROI-S06554

- 17 -

(12) In the Modem Configuration window, uncheck all five checkboxes.

RS232C setting

USB setting

(13) Retain the default setting on the Options tab and click the Security tab.

RS232C setting

USB setting

ROI-S06554

- 18 -

(14) Retain the default setting on the Security tab and click the Networking tab.

RS232C setting

USB setting

(15) On the Networking tab, verify that PPP ... is`displayed in the Type of dial-up server I am calling field and uncheck File and Printer ... and Client for Microsoft....

RS232C setting

USB setting

ROI-S06554

- 19 -

(16) Click Settings Uncheck all the boxes in the window that appears, as shown below. Click [OK] to go back to the previous window. Highlight Internet Protocol (TCP/IP) and then click [Properties].

(17) Verify that both Obtain an IP address automatically and Obtain DNS server address automatically are selected.

ROI-S06554

- 20 -

(18) In the Advanced TCP/IP Settings window, uncheck Use IP header compression for the PPP link. Click [OK].

(19) Retain the default setting on the Advanced tab and click [OK].

After activating Windows XP SP2 Before activating Windows XP SP2

ROI-S06554

- 21 -

5. SNMP Service Setting

NOTE

It is necessary to remove SNMP Service or to stop it if it has already been installed.

To Remove SNMP Service:

(1) Select Start Setting Control Panel, then, in the Add or Remove Programs window, click Add/Remove Windows Components.

(2) The Windows Components Wizard window appears. Remove the check from Management and Monitoring Tools, and then click Details ...

ROI-S06554

- 22 -

(3) The Management and Monitoring Tools window appears. Confirm that Simple Network Management Protocol is not checked and click [OK]. Return to above window and click [Next].

(4) Click [Finish] to complete the removal of SNMP Service.

ROI-S06554

- 23 -

To Stop SNMP Service: (5) To stop SNMP Service without removing it, click Administrative Tools in the Control

Panel window.

(6) Click Services in the Administrative Tools window.

ROI-S06554

- 24 -

(7) Confirm that SNMP Service is installed and it has started automatically. Select Action Properties on the menu bar in the Services window, or right-click SNMP Service and then click Properties in the SNMP Service pop-up menu.

(8) Select Manual in the Startup type field and click Stop in the Service status field on the General tab. Click [OK] or [Apply].

ROI-S06554

- 25 -

(9) Confirm that the Status of both SNMP Service and SNMP Trap Service is stopped, and that the startup condition for each one is Manual.

(10) Restart the computer.

ROI-S06554

- 26 -

6. PNMT Setup

NOTE

If PNMT software has already been installed, please uninstall it before you install a new version.

(1) Insert the PNMT Installation CDROM.Open the CDROM folder and double-click install.exe.

(2) The following window appears until loading is completed.

ROI-S06554

- 27 -

(3) Introduction window appears. Click [Next].

(4) Specify the directory in which the PNMT is to be installed. Click [Next].

Restore Default Folder: Click this button to choose the license key folder

Choose: Click this button to select another directory

NOTE

The default path is C:\PNMSj. It is not possible to include blank spaces as in “Program Files”. (C denotes the directory where the currently running OS is installed)

ROI-S06554

- 28 -

(5) Specify the License Key file if one is available. Click [Next].

Restore Default Folder: Click this button to revert to default path

Choose: Click this button to choose the license key file

NOTE

If no license key file is available, operation in trial mode is possible.

IMPORTANT: IMMEDIATE IMPORT OF LICENSE

You may use the PNMT on a trial basis for 30 days. After that the PNMT can ONLY be used IF the license has been imported (activated). To obtain the license please contact NEC.

ROI-S06554

- 29 -

(6) Click [Install].

(7) During installation, this window appears.

ROI-S06554

- 30 -

(8) Click [Done] to close the PNMT installation wizard.|

ROI-S06554

- 31 -

7. Network Connections Setting on Windows XP

(1) Select Start Control Panel

(2) Select the Network and Internet Connections from the Control Panel window.

ROI-S06554

- 32 -

(3) Select the Network Connections from the Network and Internet Connections window.

(4) The Network Connections window will appear.

ROI-S06554

- 33 -

(5) Right click the Local Area Connection and select the Properties from the context menu.

(6) The following Local Area Connection Properties window will appear as default.

ROI-S06554

- 34 -

(7) Confirm that the Internet Protocol (TCP/IP) is only checked on the General tab, and then click on the Authentication tab.

(8) The following Authentication tab will be displayed as default.

ROI-S06554

- 35 -

(9) Remove the check on the Enable network access control using IEEE 802.1X, and then click on the Advanced tab.

(10) The following Advanced tab will be displayed, and confirm that there is no check on the Advanced tab.

ROI-S06554

- 36 -

(11) Return to the General tab and select the Internet Protocol (TCP/IP), then click on the Properties button.

ROI-S06554

- 37 -

(12) The following Internet Protocol (TCP/IP) Properties window will appear. Select the Use the following IP Address instead of the Obtain an IP address automatically. Set the IP address, Subnet mask and Default gateway as follows:

Item Setting

IP Address 172.17.254.254

Subnet mask 255.255.255.252

Default gateway 172.17.254.253

DNS server address is not required. Click on the Advanced button.

ROI-S06554

- 38 -

(13) The following Advanced TCP/IP Settings window will appear. IP Settings, DNS, and WINS are not required. Select the TCP/IP filtering on the Options tab and click on Properties button.

ROI-S06554

- 39 -

(14) The following TCP/IP Filtering window will appear. Confirm that there is no check on the Enable TCP/IP Filtering (All adapters) and all the Permit All on the TCP Ports, UDP Ports and IP Protocols are selected. Click on OK button returning to Local Area Connection Properties windows.

(15) Click on Close button from Local Area Connection Properties window to complete the Network Connections Setting on Windows XP.

ROI-S06554

- 40 -

8. Launching PNMT

(1) Click Start | Programs |PNMTj |PNMT to start the application.

(2) If he following window appears, select [Unblock] (when using the Windows XP SP2 Firewall).

ROI-S06554

- 41 -

(3) Enter User name and Password, and Select the Connection Entry.

After installation of the PNMT, the initial password will be:-

User name: admin

Password: (There is no initial password. Just press Enter.

A password can then be set.)

Connection: In case of connection to 5000S select Ethernet and PNMT(LAN/Direct) entry.

Otherwise select Dialup and PNMT(RS232C)/PNMT(USB) entry.

NOTE

If another application is using the SNMP Port, application initialization will not be possible; the application will shut down, and the following message will appear.