T +86 029-81292510 : E : [email protected] Xi 'an Gavin Electronic Technology Co., Ltd W : www.gaimc.com
GUF140
PRODUCT DESCRIPTION
FEATURES
Insertion Ultrasonic Water Meter
GUF140 series Insertion ultrasonic water meter is a new-style
water meter specifically designed for agricultural
irrigation,garden management and water resource supervision.
Advantage of this water meter include low cost,high
accuracy,low power consumption,stability and reliability.1 inch
thickness of the meter helps to save the installation space,and
all parts achieve to IP68 enable the water meter work in any
severe environment.Due to the unique design structure,there
will be no pressure loss and different water medium will have no
influence on measurement. This ultrasonic water meter will be a
major breakthrough for water measurement in agricultural
irrigation.
1.Characteristics
Protection Class IP68
Whole machine waterproof :the seal property of whole machine achieve to IP68
Parts waterproof : each part achieve to IP68 separately ,ensure long term work even if the meter get into the water.
Built-in Quantitative Controllers Built-in Time Accumulator
Automatically start the controller at the set time, achieve to supply water automatically ,regularly and quantitatively
Time-sharing flow accumulation with in the set period of time ,to achieve gradient rate..
Ultrasonic measurement ,no Rotation,no worn parts
Ensure long-term high measuring accuracy .
Apply to varieties of water quality, including the water contain gravel and weeds.
Ultra-thin design
1 inch thickness of the meter helps to save installation space
Made of nylon ,high strength and corrosionResistance ,very low cost.
No pressure loss.
T +86 029-81292510 : E : [email protected] Xi 'an Gavin Electronic Technology Co., Ltd W : www.gaimc.com
Display the instantaneousflow ,cumulative flow andother working status
Easy for operation with finger
Support Bi-directional Flow Measurement
Various of Units Selected
Infrared Communication Interface
Could measure instantaneous flowand cumulative under the forwardand backward direction separately
Cumulative flow :m³,ft3,GAL ,LInstantaneous flow :m³/h, GPM, L/m
Support CJ-188 and M-bus communication protocolSupport software upgrade
58×22mm LCD
Smart Touch Key
2.Display and operation
SIZE AND WEIGHT
147
147
147
147
68
78
90
103.5
280
270
305
318
140
160
184
212
Nominal Size DN(mm)
DN80
DN100
DN125
DN150
L H1 H2Outer DiameterD1
160
180
210
240
Central circlediameter ofbolt holes D
Bolt hole
Bore diameter* quantityφ*n Quantity
18*8
18*8
18*8
22*8
2
2
2
2
1.1
1.2
1.4
1.5
Weight kg
PressureMPa
1.6
1.6
1.6
1.6
Dimension Flange size
Unit :mm
L
H2
H1
D1D2
25.4
Nominal Diameter(mm) R
Flow(m³/h)
Starting Flow rate
Minimum Flow rate Q1
Transitional Flow rate Q2
Permanent Flow rate Q3
Overload Flow rate Q4
DN80
DN100
DN125
DN150
40
40
40
40
0.625
1.000
1.250
1.5625
2.500
4.000
5.000
6.250
4.000
6.400
8.000
10.000
100.000
160.000
200.000
250.000
125.000
200.000
250.000
312.500
Flow range:
T +86 029-81292510 : E : [email protected] Xi 'an Gavin Electronic Technology Co., Ltd W : www.gaimc.com
SPECIFICATIONS
Item
Standard
Measure fluid
Medium temperature
Working environment
Pressure
Pressure loss
Upstream sensitivity
Downstream sensitivity
Climate and mechanical
Electromagnetic compatibility class
Communication interface
Output signal
Power supply
Protection level
Digital display
Data storage
Measurement cycle
Power consumption
Specification
ISO 4064-2005,GBT 778-2007
Water,sewage,seawater(other liquid need to be customized)The pipeline should be full of liquid
0.1-30℃
Temperature:-30-45℃;humidity≤100%(RH)
1.6Mpa
None
U5
D3
C level
E2 level
RS485/USART/Infrared
Two way OCT or TTL pulse output/one way 4-20mA analog output
Built-in lithium battery(3.6V,19Ah)/DC8-36V power supply/two-wire system 4-20mA
IP68 ,available to work 2 meters underwater
9 digits cumulative flow and 4 digits instantaneous flow shown in two rows and
varies of state prompt and units
Use EEPROM/Flash,automatically record the cumulative flow of last 128 months and last 512 days
Measuring:1 times/second:verification:4 times/second
≤2.7AH/Year,6 years battery life
TYPE SELECTION
GUF140 Note
DNXXDiameter DN80,DN100,DN125,DN150
Communication Interface
Output signal
Wireless Meter reading
Output cable
Protective cover
0 None
R RS485
M M-BUS
None
Two-wired system 4-20mA
OCT1(open-collector output 1)
OCT2(open-collector output 2)
C1(TTL level pulse output1)
C1(TTL level pulse output2)
0
T
O1
O2
P1
P2
0
R
None
RF communication module
Standard is 1m. other length:waterproof junction box +extended output cable(default)M
0 None
1 Optional