24
Innovative/Alternative Septic System Performance System Performance and Tracking it with the Carmody Database Barnstable County Department of Health and Environment

Innovative/Alternative Septic System Performance

Embed Size (px)

DESCRIPTION

Innovative/Alternative Septic System Performance. System Performance and Tracking it with the Carmody Database. Barnstable County Department of Health and Environment. By The Numbers. Permit Breakdown by System Type. Numbers are for the town of Wellfleet only. Box-Whisker Diagrams. - PowerPoint PPT Presentation

Citation preview

Page 1: Innovative/Alternative Septic System Performance

Innovative/Alternative Septic System Performance

System Performance and Tracking it with the Carmody

Database

Barnstable County Department of Health and Environment

Page 2: Innovative/Alternative Septic System Performance

By The NumbersPermit Breakdown by System Type

System Type Number Percent

Advantex 11 11%

Amphidrome 3 3%

Bioclere 16 16%

Clivus 2 2%

FAST 37 37%

Orenco 5 5%

Puraflo 2 2%

RSF 7 7%

Septitech 8 8%

Singulair 4 4%

Waterloo 5 5%

White Knight 1 1%

Total 101  

Numbers are for the town of Wellfleet only.

Page 3: Innovative/Alternative Septic System Performance

Box-Whisker Diagrams

50%

Probability Density Graph (“Bell Curve”)

Median – Middle Value

Min/Max ValueBox

Whiskers

What are they?

Min/Max Value

25% 25%

Page 4: Innovative/Alternative Septic System Performance

0

10

20

30

40

50

60

Box-Whisker DiagramsWhat Can We Use Them For?

A B C D

A – A “Good” System. Box and whiskers are short and compact.

B – A “Bad” System. Results are all over the place. Box and whiskers are stretched out.

C – A “Consistently Bad” System. Compact but well above TN limit (19 mg/l)

D – A “Usually Pretty Good” System. Compact but maybe a couple of high results.

Page 5: Innovative/Alternative Septic System Performance

0

50

100

150

200

250

300

Individual Systems

To

tal

Nit

rog

en

(m

g/l

)

Single Family all Types by Individual SystemThree or More Samples with Full Nitrogen Series

•761 systems with 3 or more TN samples

•569 of 761 (75%) with median TN <19 mg/l

Page 6: Innovative/Alternative Septic System Performance

0

50

100

150

200

250

300

Individual Systems

To

tal

Nit

rgo

en

(m

g/l

)

Single Family all Types by Individual SystemThree or More Samples with Full Nitrogen Series

•42 systems with 3 or more TN samples

•29 of 42 (69%) with median TN <19 mg/l

Page 7: Innovative/Alternative Septic System Performance

Single Family all Types by System TypeThree or More Samples with Full Nitrogen Series

0

20

40

60

80

100

120

140

Clivus Advantex Waterloo Biofilter Bioclere Singulair FAST Septitech

System Type

To

tal

Nit

rog

en

(m

g/L

)

Page 8: Innovative/Alternative Septic System Performance

0

5

10

15

20

25

30

35

40

45

50

WEEas031Adv WEFra050Adv WEChe599Adv WECli175Adv WECra120Adv WEEas022Adv WERyd20Adv

Individual Systems

To

tal

Nit

rog

en

(m

g/l

)

Single Family AdvantexThree or More Samples with Full Nitrogen Series

•7 systems with 3 or more TN samples

•6 of 7 (85%) with median TN <19 mg/l

Page 9: Innovative/Alternative Septic System Performance

0

10

20

30

40

50

60

70

80

Individual Systems

To

tal

Nit

rog

en

(m

g/l

)

Single Family BioclereThree or More Samples with Full Nitrogen Series

•7 systems with 3 or more TN samples

•7 of 7 (100%) with median TN <19 mg/l

Page 10: Innovative/Alternative Septic System Performance

0

20

40

60

80

100

120

140

Individual Systems

To

tal

Nit

rog

en

(m

g/l

)

Single Family FASTThree or More Samples with Full Nitrogen Series

•10 systems with 3 or more TN samples

•7 of 10 (70%) with median TN <19 mg/l

Page 11: Innovative/Alternative Septic System Performance

0

50

100

150

200

250

300

Individual Systems

To

tal

Nit

rog

en

(m

g/l

)

Single Family OrencoThree or More Samples with Full Nitrogen Series

•4 systems with 3 or more TN samples

•1 of 4 (25%) with median TN <19 mg/l

Page 12: Innovative/Alternative Septic System Performance

0

10

20

30

40

50

60

70

80

Individual Systems

To

tal

Nit

rog

en

(m

g/l

)

Single Family Generic RSFThree or More Samples with Full Nitrogen Series

•2 systems with 3 or more TN samples

•0 of 2 (0%) with median TN <19 mg/l

Page 13: Innovative/Alternative Septic System Performance

0

10

20

30

40

50

60

70

80

90

Individual Systems

To

tal

Nit

rog

en

(m

g/l

)

Single Family SeptitechThree or More Samples with Full Nitrogen Series

•7 systems with 3 or more TN samples

•5 of 7 (71%) with median TN <19 mg/l

Page 14: Innovative/Alternative Septic System Performance

0

10

20

30

40

50

60

70

80

90

100

Individual Systems

To

tal

Nit

rog

en

(m

g/l

)

Single Family SingulairThree or More Samples with Full Nitrogen Series

•2 systems with 3 or more TN samples

•2 of 2 (100%) with median TN <19 mg/l

Page 15: Innovative/Alternative Septic System Performance

0

10

20

30

40

50

60

70

80

90

Individual Systems

To

tal

Nit

rog

en

(m

g/l

)

Single Family Waterloo BiofilterThree or More Samples with Full Nitrogen Series

•3 systems with 3 or more TN samples

•1 of 3 (33%) with median TN <19 mg/l

Page 16: Innovative/Alternative Septic System Performance

0

10

20

30

40

50

60

70

80

90

100

Individual Systems

To

tal

Nit

rog

en

(m

g/l

)

Single Family SeptitechThree or More Samples with Full Nitrogen Series

20 Hideaway Lane

0

10

20

30

40

50

60

6/16/06 7/12/06 8/30/06 7/18/07 7/24/08 8/29/08 7/28/09 9/2/09 8/26/10

To

tal

Nit

rog

en (

mg

/l)

20 Huckleberry Lane

0

10

20

30

40

50

60

70

80

90

7/27/04 9/15/04 7/27/05 9/2/09 8/26/10

To

tal

Nit

rog

en (

mg

/l)

26 Longstreet Lane

0

10

20

30

40

50

60

70

80

90

8/24/05 7/12/06 7/12/06 8/30/06 7/18/07 8/30/07 7/29/08 9/8/08 9/2/09

To

tal

Nit

rog

en (

mg

/l)

495 Campground Road

0

10

20

30

40

50

60

70

80

7/24/03 9/12/03 7/27/04 9/15/04 7/20/10

To

tal

Nit

rog

en (

mg

/l)

31R Martha Ave

0

10

20

30

40

50

60

70

80

90

8/30/06 7/18/07 8/30/07 7/29/08 7/28/10

To

tal

Nit

rog

en (

mg

/l)

Page 17: Innovative/Alternative Septic System Performance

Single Family all Types by System TypeThree or More Samples with Full Nitrogen Series

System Type

Total with 3+ Samples

Total below 19mg/l

Wellfleet

Percentage

Cape-Wide Percentage

All Types 42 29 69% 75%

Advantex 7 6 85% 78%

Amphidrome 75%

Bioclere 7 7 100% 74%

FAST 7 10 70% 80%

OMNI RSF 51%

RSF (Generic) 0 2 0% 56%

RUCK 50% 50%

Septitech 5 7 71% 33%

Singulair 2 2 100% 90%

Waterloo 1 3 33% 64%

Page 18: Innovative/Alternative Septic System Performance

Keeping Track of it All…Quickly Identifying Poorly Performing Systems

Sample Reports

Use to obtain a list of the most recent sample exceedances (anything

over 19 mg/l)

Two 25% Exceedances

Use to generate a list of systems with two

samples exceeding 19mg/l by 25% (24mg/l).

One 50% Exceedance

Use to generate a list of systems with one sample

exceeding 19 mg/l by 50% (30 mg/l)

Page 19: Innovative/Alternative Septic System Performance

Keeping Track of it All…Sample Reports Messages

25.83 mg/L > 19mg/L(36%) for Total Nitrogen 1 Consecutive 4 Non-Consecutive (25.83,8.54,43.4,29.35,24.1)

Amount of the Exceedance

Exceedance Percentage

Exceeding Parameter

Number of Consecutive Exceedances

Number of Non-Consecutive Exceedances

Results from the Last Five Samples

Page 20: Innovative/Alternative Septic System Performance

Keeping Track of it All…Quickly Identifying Poorly Performing Systems

Sample Reports

Use to obtain a list of the most recent sample exceedances (anything

over 19 mg/l)

Two 25% Exceedances

Use to generate a list of systems with two

samples exceeding 19mg/l by 25% (24mg/l).

One 50% Exceedance

Use to generate a list of systems with one sample

exceeding 19 mg/l by 50% (30 mg/l)

Page 21: Innovative/Alternative Septic System Performance

Keeping Track of it All…Sample Exceedance Report

List of the last 5 samples

Remove the flag for this system. Will reappear on this list with

another exceedance.

Select the Report Type: 2 over 24mg/l,

1 over 30mg/l or merged report.

Export the current list to MS

EXCEL

Page 22: Innovative/Alternative Septic System Performance

Keeping Track of it All…Exporting the Sample Exceedance Report to EXCEL

System ID Home Owner Municipality Sampling History

EASte595FAS

Savage, Joseph595 Steele RoadEastham,MA Eastham

5.28 10/7/201014.25 7/12/201011.23 10/14/200924.37 7/9/200952.1 8/21/2007

EAR06420ADV

Seatoller LLC, Steve Lang4205 State Highway Route 6Eastham,MA Eastham

28.84 3/9/201132.45 2/1/201145 1/5/2011

EATur265FAS

St. Aubin, Lucille and Carol265 Turnip RoadEastham,MA Eastham

24.03 9/27/201024.03 9/27/201013.49 6/26/200920.94 9/17/200819.5 6/25/200743.1 9/27/2006

EATur245FAS

St. Aubin, Lucille and Carol245 Turnip RoadEastham,MA Eastham

34.92 7/8/201016.87 12/10/20082.94 10/23/200829.9 3/4/200883.5 12/21/2007

Page 23: Innovative/Alternative Septic System Performance

Town of Eastham Sample Exceedance Report - 3/29/2011

System ID Home Owner Municipality Sampling History Median Average StDev

EASam300Sep

Baughman, James and Amanda300 Samoset RoadEastham,MA Eastham

19.61 8/26/201019.61 8/26/201022.56 7/28/201041.37 8/28/200924.44 7/28/200913.73 8/29/2008 21.085 23.55333 9.453086

EASun093Adv

Bechgaard, Candace93 Sunset AvenueEastham,MA Eastham

26.86 2/2/201115.06 7/27/201017.05 4/26/201027.86 1/28/20104.53 8/27/2009 17.05 18.272 9.569957

EAR06418RSF

Brown, Robert4180 Route 6Eastham,MA Eastham

80.6 11/2/201029.31 7/20/200940.1 6/9/200844.5 10/23/200715.3 10/3/2006 40.1 41.962 24.36052

EACam760FAS

Civita, George760 Campground RoadNorth Eastham,MA North Eastham

130.65 11/21/200877 6/9/200856.7 9/18/200723.9 5/14/200740 10/3/2006 56.7 65.65 41.33676

EABri220Bio

Conlin, Kevin220 Bridge RoadEastham,MA Eastham

20.46 1/5/201137.98 7/19/20106.65 1/8/201035.84 7/13/200921.06 1/2/2009 21.06 24.398 12.81631

Keeping Track of it All…“Cleaned Up” Sample Exceedance Report

• Exceedance reports will be delivered quarterly.

• BOH will decide what action to take, since each BOH will likely have a different policy.

Page 24: Innovative/Alternative Septic System Performance

Innovative/Alternative Septic System Performance

Brian Baumgaertel508-375-6888

[email protected]

Barnstable County Department of Health and Environment