Sulzer Pumps
Innovative Produktentwicklungen bei Kreiselpumpenfür das Segment HPI ( Erdöl, Gas, Petrochemie )
Sulzer PumpsInnovative Produktentwicklungen bei Kreiselpumpenfür das Segment HPI ( Erdöl, Gas, Petrochemie )
• Mantelgehäusepumpen mit gegenläufiger Laufradanordnung
• Magnetgekuppelte mehrstufige API-Pumpen ( horizontal und vertikal )
• Magnetgekuppelte API-Pumpen mit Doppelspalttopf für besondere Anwendungen
• Einstufige API-Pumpen für kleine Fördermengen und große Förderhöhen
• Einstufige Mehrphasenpumpen und Hybrid Pumpen
Sulzer PumpsGSG – Design Overview
In Line, Bolted Cover
Twist Lock or Bolted Cover
50-220, 80-260, 80-310, 100-300, 100-350, 125-330, 150-360, 150-390
Low Pressure, 110bar40-180, 50-220, 80-260, 100-300, 125-330, 150-
360, 200-400
High Pressure, 250bar,100-300, 125-330, 150-
360, 200-400
Back to Back max. 400bar
High Temperatur 400°C, only Bolted Cover
Twist Lock
Bolted Cover
Sulzer Pumps
Wälz- oder Gleitlagervorhanden
Radialgeteilte, identischeStufengehäuse, Lauf und
Leiträder
Zwischenentnahmemöglich Sauglaufräder oder
doppelflutige Laufrädervorhanden
Radialgeteiltes,geschmiedetes odergegosenes Gehäuse,
gekammerte DichtungenInline- Rotor mit
EinzelradabstützungEntlastungskolbenund E- Buchse
GSG Inline – Hauptbauteile
AuswechselbareLabyrinthe
BefestigungGehäusedeckel mit"Super- nuts" beihohen Drücken
Sulzer Pumps
API 610 / ISO 13709 verlangt eine stabile Rotordynamik auch bei zweifachemSpaltspiel. Das ist bei der Inline Ausführung nur bis zu einer bestimmten Stufenzahlmöglich und begrenzt damit die Förderhöhe bei Pumpen mit Direktantrieb.
•Die Mittelbuchse wirkt als hydrostatisches Lager, der Lomakin – Effectbewirkt kontaktfreien Lauf im Betrieb
•Hohe Stufenzahlen auch bei niedrigen Viskositäten•Verringerung des Lagerabstandes•Durchbiegung der Welle reduziert, Welle liegt auf der
Mittelbuchse auf•Reduzierter Restaxialschub, kleinere Lagergrößen•Druckölschmierung nach API Kriterium•Keine Axialschubbeeinflussungdurch Verschleiß der Spaltringe
Vorteile der Back to Back Ausführung
L
L/2
L/2
Sulzer Pumps
FDrum ~ 85% Fa TotalFa Total = Fa 1st+Fa nst
� Durch die gleiche Anordnung aller Laufräder summieren sich die Axialkräfte.
Fa 1st
X X X X
Fa nst
� Unterschiedliche druckbeaufschlagte Flächen vor und hinter dem Laufrad erzeugeneine Axialkraft in Richtung Saugseite
Ps
FDrum
� Die gesamte Axialkraft wird durch den Entlastungskolben theoretisch ausgeglichen. Das Axiallager nimmt die Restaxialkraft auf.
Ps nst
Pd 1stPs 1st Pd nst
GSG – Axialschub bei Inline Bauweise
GSG Inline
Sulzer Pumps
AxialschubRestaxialschub
GSG – Axialschub bei Back to Back- Bauweise
Axialschub
Durch die gegenläufige Anordnung der Laufräder wird der Axialschubesfast vollkommen ausgeglichen. Bei Verschleiss der Spaltringe wird der
Restaxialschub nur geringfügig beeinflusst.
Sulzer PumpsGSG – Hochtemperaturausführung
Spezielle Ausführung für Betriebstemperaturen > 260°C
GraphitAbdichtungen
erweiterteSpaltspiele
Stufengehäuse mitMetallabdichtung
Elastische Befestigung derEntlastungsbuchse,
verhindert ein verringerndes Kolbenspieles
Mantelgehäuse mitBeheizung
dampfbeheizte neueAnordnung der GLRD
Sulzer PumpsGSG – Befestigungsmöglichkeiten der Gehäusedeckel
• Stiftschrauben und Muttern – wie bisher – hohe Drehmomente, unsichere Schraubenkraft, oder,
Deckel installiertDeckel eingeführt und
teilweise gedreht
Deckel in Position und fixiert
• Sulzer Patent, "Twist Lock" Twist- Lock- Druckdeckel, kleinereGehäusewandstärke – keine Schrauben und Muttern, schnellere Demontage.
• Supernuts – Anziehen von Hand mit Drehmomentschlüssel, oder,
Sulzer PumpsGSG back to back, Sleeve-Ball-Lagerung
Schrägkugellager, O-Anordnung, nur
axialbelastet,Ringölschmierung,
Radial-GleitlagerRingölschmierung
Lagerkühlung, drs. drehrichtungsabhängig
Haltering fürSchrägkugellager
Lagerträger axial-geteilt
Lagerkühlung, sgs. drehrichtungsabhängig
Konisches Wellenende mitSicherungsmutter
Lagerträger eingestelltund verstiftet
AuswechselbareLagerabdichtung, IMPRO
Sulzer PumpsGSG back to back, Pumpe-Saugseite
Anschluss Zirkulation zurDruckseite
Eintritt Entlastungsstrom zurersten Stufe
Anschluss Zirkulation zurSaugseite
O-Ring Abdichtung, Druck 2.Stufe
Sulzer PumpsGSG back to back, Centerbuchse
Druckseitige Stufenpaket mitDehnspalt
Federn zur Anpressung des druckseitigen Stufenpaketes
Centerbuchseelastisch fixiert
Saugseitiges Sufenpaket mitMontageschrauben gehalten
Laufräder mit leichtemSchrumpfsitz, 0,1mm
unterschiedlich
Entleerung Enddruckraum
Centerhülse
Sulzer Pumps
GSG back to back – 3-fach-Gleitringdichtung(Fördermedium Propylen)
Plan 23 Kühlung GLRDAnschluss Zirkulation von 2.Stufe NS, von 1.Stufe AS
Befestigung mitSchrumpfscheibe
Einstellhülse fürsichere Abstützung
gegen geteilten Ring
Spülbohrung mit Blende fürausreichenden Druck und
Zirkulation
Pumpring
Sulzer PumpsGLRD mit dampfbeheizten Räumen
Heizräume um die Gleitringdichtung
Sulzer Pumps
Protection devices
GSGM Pump Features
Barrel
Cover
PLB
Containment shell
Safety seal
PLB
Outer rotorInner rotorBalance
device
Hydraulic parts from Multistage Programme
Hollow shaft
PT100
Motor with Flange
Sulzer PumpsGSGM 50-220/10 Zirkulationsströme
Entlastungsstom durch die Welle zur 1. Stufe, Teilstrom durch das Lager NS
Zirkulation Magnetkupplung, von 1.Stufe über Magnetkupplung durch die Welle zum Eintritt vor erster Stufe, Teilstrom durch das Lager AS.
Sulzer PumpsGSGM Vorteile
• Pumpe ist nach API 610 ( ausser E-Scheibe)
• Pumpe ist hermetisch dicht
• Keine ölgeschmierte Lagerung notwendig
• Verringerung der Überwachung, (kein Vorlagesystem für GLRD)
• Kürzeres Aggregat
• Geringer Lagerabstand, sehr gute Rotordynamikwegen kurzer und dicker Welle, verringerteVibration und Geräuschemmission
• Weniger Instrumentierung
Sulzer Pumps
Balance Counter Disc
Pump Shaft
Balance Disc
Split Ring
PEEK Thrust Ring
Balance Devise for Axial Thrust Compensation
Sulzer PumpsSafety Seal for Pumps with Magnetic Coupling
Dry-running Gas Phase SealTyp CGSX/35
sealing ring
U-groovesindependent of rotational sense
stationary counter ring
sealing casing
multi springs
Advantages• No maintenace required
• Static pressure up to 75bar
• No edditional heating
• Independent of rotating
direction
Sulzer PumpsSealess HPI Pump, Type GSGM back to back
High EfficiencyMagnet Coupling
Axial / Radial Bearing
Hydro dynamicradial bearings
Sulzer Pumps
TTMCM Pumpen werden bevorzugt eingesetzt wennbrennbare, explosive, aggressive oder giftige Medien ohneLeckage gefördert werden müssen. Diese Medien habenmeist einen geringen Druck über dem Dampfdruck(NPSHA). Der notwendige Zulaufdruck wird durchtiefersetzen des Sauglaufrades erzeugt.
Einsatzgebiete
� Raffinerien� Chemische und Petrochemische Industrie� In Gasverflüssigungsanlagen� In der Kältetechnik
Ein großer Vorteil ist auch der geringe Platzbedarf
TTMCM – Anwendung in der Industrie
Sulzer Pumps
� Die Sulzer TTMCM-Pumpen sind vertikale, mehrstufige, radialgeteilte Pumpen mit Magnetkupplung
� Druckbelastete Teile sind nach API 610 ausgeführt� Magnetisches Axiallager� Axialschubausgleich durch Entlastungsscheibe
und - Gegenscheibe� Magnetkupplung mit hohem Wirkungsgrad� Retrofit von Pumpen mit Gleitringdichtung möglich
TTMCM Beschreibung
Sulzer Pumps
NML Magnetkupplung
PERMAVOR als magnetisches Axiallager
Sicherheits-gasdichtung
Selbstreinigender Magnetfilter für den Zirkulationsstrom
Anschluss für Lekage-und Druckwächter
TTMCM Konstruktions - Details
Produktgeschmierte Gleitlager, Siliciumcarbid / SUME-SOL ( SULZER Patent)
Sulzer PumpsTTMCM Konstruktions - Details
Axialschubausgleich,Entlastungsscheibe/ -Gegenscheibe
Laufräder,Leiträder und Stufengehäuse vom horizontalen, mehrstufigen Programm
interne Zirkulation durch die Welle
Druckleitung zum Axilschubausgleich
Spezielles Einlaufgehäuse für excellente NPSHR Werte
Produktgeschmierte Gleitlager, Siliciumcarbid / SUME-SOL ( SULZER Patent)
Sulzer PumpsTTMCM typische Anwendungen
• Medium: Flüssiggas � Propan, Butan, Ethane• Ethylene, Propylene• Kohlenwasserstoffe �Benzin, Benzol, Ethanol
• Temperatur:-56°C up to 120°C (150°C Auslegungstemperatur)
• Ausführung: Infloor � geringes NPSH A•• Overflow � genügend NPSH A
Sulzer Pumps
Train of TTMCM‘sin a Liquid Gas Plant
BASF Germany
TTMCM Referenz
Sulzer PumpsReference TTMCM OMV Burghausen
Pump size TTMCM 50-180/9
Medium HC + 5% Ethylbenzol
Capacity 66,5 m³/h
Head 332 m
Design pressure 40 bar
Operating temp. 25°C
Motor Power 90 kW
Sulzer PumpsHigh efficiency containment shell
Fixation flange
Disc springs preloading the segmental rings
Slotted outer shell
Segmental rings (isolated and sealed)
Deep drown Containment shell
Advantage:Segmental containment shell has only 20% of
the Eddy Currents, compared to the Deep drown containment shell
Drive Magnets
Containment Shell
Driven Magnets
Sulzer PumpsTTMCM - Balance device , disc / counter disc
Balance Disk
Balance Counter Disk
Pressure Chamber
Axial pre throttle gap
Radial throttle gap
Advantages•No residual axial trust
•independent of viscosity
•high efficience
•Axial pre throttle has the
effect as an product
lubricated bearing
Sulzer PumpsTTMCM - Product lubricated bearing
•Coating can be aplied directlyto rotors and stators, easelyreplacable
•maximum sliding wearresistance
•high load-bearing capacity
•solid lubricant dispersion to promote lubrication underextreme conditions
Bearing housing
Bearing sleevecoated with
SUME® SOL 220
SUME® SOL 220 layer
Basic sleeve material
Silicon Carbide bushing
Sulzer PumpsMagnetically axial Bearing
Rotor displacement [mm]
Axial Forces with 10 Magnetic Rings
RotorStator
Sulzer PumpsTTMCM - Standard Safety Instrumentation
Gas phase mechanical seal, dry running, designed for high pressure, allow increasepressure in the secondarycontainment.
Load Monitor installed in the motor cable, indicatedry running or cavitationby power dropping.
PT100-Temperature Monitoringof the circulation fluid, indicateplugged circulating path.
Liquide detector on discharge line, best way to see that the wholepump is filled withmedium.
Liquide detector on suction line, necessary for fluidgas loading pumps.
Pressure indicator, shut down the motor if 2bar indicated.
Liquide detector on secondary containment (onlyif the medium vaporepressure < atmosphare)
Sulzer PumpsTTMCM Self purifying Magnetic Strainer
Circulation fluid
6 Magnetic rings around on the stationary retainer
Rotating Plate
Function of the Strainer:
Magnetic particles in the circulation fluide will be collect by the stationarymagnets. If the clearance between the magnets and the plate is full of particles, therotating plate will thow avay the particles and open the circulation path.
Sulzer PumpsZEM 50- 450 mit Doppelspalttopf,
Anschluss, Drucküberwachung Spalttopf/Inliner
ZE - Bauteile
OHM - BauteileGehäusedeckel:
MonelStahl Magnetkupplung
NMB 685 22P–35-4R ND2 + Monell
Mitnehmer als Ventilator
Zwischenstück mit Kühlrippen
Zirkulationsanschlussmit Monelrohr
Sulzer Pumps
Inliner: 0,6mm dick Monell 400 oder K-500
Anschluss zur Drucküberwachung
Segmentspalttopf in vorhandener Konstruktion
Inliner mit Flansch verschweißt oder
verschraubt
Doppelspalttopf für Magnetkupplung
Sulzer PumpsDoppelspalttopf, Konstruktionsdetails
Ausbau des Inliners
Nut im Segmentspalttopf für DruckanzeigeMagnetkupplungsprüfstand
Sulzer PumpsÜberwachungssystem für Doppelspalttopf
Anschluss zur Warte
Verbindung zum Überwachungsraum
Testanschluss
Drucküberwachung
Secondary Containment
Inliner ( rot )
Sulzer PumpsDoppelspalttopf, Vorteile / Nachteile
Vorteile• Keine Abdichtung der Spalttopfsegmentringe zum Fördermedium
• Schnelles Ansprechen der Überwachung
• Geringerer Schaden beim Versagen der Lagerung undAnstreifen des Innenrotors
• Einfachere Reparatur des Spalttopfes ( evtl. nur Inliner)
• Verzicht auf Gasdichtung
• Secondary Containment ist nicht druckbelastet
• bei kritischen Medien ist nur der Inliner medienberührt
Nachteile:• Höhere Verlustleistung durch die zusätzliche Wand des Inliners
• Eventuell niedrigere, zulässige Drücke oder reduziertes Drehmoment
Sulzer Pumps
Prüffeldaufbau SWB
Sulzer PumpsPrüffeldaufbau SWB
Sulzer PumpsLow Flow Overhung Development
• The low flow range map begins at < 1m3/h and goes to about 50 m3/h
• Heads required are similar to those of larger flow overhung pumps. Customers always want more head, so we pushed the limit to see how far we could go in a single, overhung impeller
• While ISO 13709 prefers enclosed impellers, they are not practical at such low width to diameter ratios, so a semiopen impeller design was utilized
• Barske impeller designs have been used for many, many years. They have many vanes and make much head per stage, but are typically unstable (droop toward zero flow)
• Producing a pump with a stable curve, was the challenge.
Sulzer PumpsLow Flow Overhung Development
• The bearing frame utilized for the low flow pump is the same as for the larger flow rate overhung pumps (for both end suction and vertical inline versions). Only the shaft end under the impeller is different due to the different impeller design required.
• ISO 13709 specifies the seal chamber dimensions and ISO 21049 requires use of cartridge type mechanical seals. The low flow pumps utilize the same seal as used in the global overhung pumps.
• The hydraulic components are the difference.
Sulzer PumpsLow Flow Overhung Development
• Several impeller designs were tested with several different casings and diffusers.
• We wanted to achieve best available head coefficient, and best achievable efficiency
• All those "wants" had to occur while maintaining a stable head – capacity curve
• After much prototype testing, we found we were not able to achieve all the requirements in just a circular volute. We looked at bypassing the unstable portion of the curve through internal drillings, but the efficiency was not attractive in larger low flow sizes.
• In the beginning, we were unable to achieve stable H-Q curve even with our best impeller and diffuser configurations. It took months of CFD work and more testing before we finally were able to achieve reasonable results – with stable curves.
Impellers are investment cast.
Inducer optional on larger sizes
Sulzer PumpsIf we build it, we must test it…
• ISO 13709 requires performance testing of each pump. Customers often desire NPSH testing if their NPSHa is very close to the pump's NPSHr.
• The production test loops at some of our factories were not optimized for extremely low flow and very low NPSH testing
• A new test loop was installed that solved both problems. It allowed us to measure extremely low flow rates with assurance. It allowed us to pump down the test loop much more rapidly in order to do vacuum suppression NPSH testing at low values.
Sulzer PumpsLow Flow Overhung Development
• ISO 21049 requires that the minimum orifice size used in seal flush piping must be 3mm or larger.
• We used that logic to size our minimum diffuser throat - 3mm. That limited how low the Best Efficiency Point flow will be.
• The small diffuser throats cause rapid decrease in head beyond BEP. For that reason, we limited the low flow curves to about 105% of BEP.
• To achieve world class performance, some of the diffuser throats are not straight lines. With such small dimensions, machining techniques took some time to perfect.
• Due to the very low flows and relatively high head generated, the efficiencies are sometimes very low – some at 5% or less – which may be hard to believe, but that is world class for that Nq
Sulzer PumpsLow Flow Overhung Development
• From the previous example, with 5% efficiency, 95% of the power is going toward heat generation. Many HPI customers don't worry about pump temperature rise since they are adding heat to their process anyway.
• However, temperature rise and vapor pressure increase in light hydrocarbons, becomes important.
• Such low flow pumps are "partial emission" designs meaning that only a small portion of the fluid circulated by the impeller passes through the diffuser throat and out the discharge. There is much mixing of the fluid from the impeller discharge back into the impeller eye.
• On fluids with a rapid increase in vapor pressure for a few degrees temperature increase, consideration must be given to vapor pressure at discharge temperature, but at suction pressures.
Sulzer PumpsLow Flow Overhung Development
• Some of our low flow single stage sizes will make > 300 m head at 2950 rpm, > 400m at 3560 rpm. Power levels can exceed 300 kW
• Even with efficiencies approaching 50% on larger low flow sizes, temperature rise is still a concern in propane, butane, ethane and other light hydrocarbons with steep VP vs T curve. The same pump would run well on water or heavy hydrocarbons with flatter VP vs T curve.
Example: Small Propane Pump for 130m head, 6% eff:T. R. (oC) = 0.00981 x Head (m) x [(1/eff) – 1]
c (kJ/kg/K)= 0.00981 x 130 x [(1/0.06) – 1] = 8.7 oC
2.3
Sulzer PumpsLow Flow Development
• Temperature rise at startup against a closed valve is another concern due to the small liquid volume in the pump casing. Low flow, single stage, high speed pumps have same issue.
• It is evident that these pumps may be applied to a number of customer hydraulic requirements. However, they are not the "cure all" and we must understand the limitations to avoid misapplication
T.R. degrees/minute at shutoff = T.R.(oC) = kWso x 60
liters x CpA pump with 11 kW shutoff power, 7.4 liter liquid volume on hydrocarbon with 2.1 cp, will create a T.R. of 42 oC/minute
Sulzer PumpsAlternatives
• Multistage pumps are more efficient (and more expensive)
• They are available in horizontal and vertical configurations
• Horizontal multistage are limited on number of stages
• High speed pumps are more efficient, but have same issue with small casing and temperature rise at startup –pump could be full of vapor in less than a minute
• Positive Displacement pumps are more efficient but depending upon the type, may present sealing or pulsation issues
Sulzer PumpsSingle Stage Multiphase
• For frothy or vapor entrained fluids, we developed a single stage, helicoaxial pump
• The hydraulic components are from a stage piece utilized in our large multistage multiphase pumps.
• The bearing frame is from the overhung end suction products discussed on the previous slides
• Due to small market size, pumps are engineered to order
Sulzer PumpsGas Tolerant Hybrid Pump
For higher dP and vapor entrained fluids, the gas tolerant hybrid pump was developed
Several stages from our multiphase pump are on the suction end. Those are used to compress the vapor into a small volume or into liquid phase
Those are followed by conventional centrifugal, radial flow multistage pieces
Note the substantial shaft and bearing system
Due to limited market, pumps of this type are engineered to order
Sulzer PumpsQuestions / Discussion
• Questions
• Discussion
Thank you for your attention !