ELCO ConFlexInnovative Fastening Technology
EL1017_single_pages.indd 1 3/15/16 7:28 AM
The #14 Conflex has a more robust cross-sectional area to deliver a
significant improvement in connection strengths! Performance
Value
Conventional 1/4" Screw Fastener #14-6 ConFlex
Shear (Lbs. Force)
2,630 3,008
* Ultimate Load Capacity at 6,000 PSI Normal Weight Concrete 1-3/4"
Embedment
Hex Head
Higher Hardness Zone For Efficient Thread Tapping
Grade 5 Hardness Zone For Strength And Ductility
2.75 2.75 2.75
NEW! #14
screw anchoring system Virtually immune to embrittlement
failure!
The extraordinary performance capability of the #14-6 ConFlex
screw-anchor is a result of its larger tensile stress area and
ductile characteristics.
New #14 diameter ConFlex Standard 1/4" diameter Thread diameter
0.275" 0.255" Minor or root diam- eter 0.210" 0.161"
Unthreaded section 0.220" 0.189"
Tensile stress area 0.0346 IN² 56% Larger Stress Area! 0.02217
IN²
Heat Treatment Grade 5 dual-hardened process. The Load Bearing Area
is Grade 5 hardened (Rockwell C 28-34) and the lead threads are
heat treated to a higher hardness level for thread tapping
capability.
Case hardened; General industry standards for hardness is RC 52
min. on case and RC 32-40 for the core.
Immune to embrittlement failure? Yes No
72% INCREASE
14.4% INCREASE
Product Snapshot
Drill Bit Diameter 7/32" ANSI
Dimensions:
Unthreaded Shank Dia. .0.218"
Head Styles: Hex Washer Head, Flat Phillips Head, Trimfit Phillips
Flat Head
Mechanical Characteristics Ultimate Load (Lbs.)
Tensile Yield (Fy) 4225 lbs
Tensile Ultimate (Fu) 4750 lbs
Tensile stress area: 0.346 in2
The over-sized #14 diameter ConFlex screw-anchor provides virtual
immunity to embrittlement failure. Embrittlement failure of screws
can be caused by hydrogen assisted stress corrosion cracking
(HASCC) as a result of dissimilar metal connections in the presence
of moisture. With the enhanced ductility of Grade 5 dual-hardened
ConFlex screws, you won't encounter "broken blue screws" anymore!
In addition, with its over-sized design and patented 40-45° thread
profile, it provides enhanced anchor and connection strengths
compared to the common alternating high and low thread design of
standard concrete screws. - Virtual immunity to embrittlement
failure - Superior connection strengths compared to conventional
1/4" concrete screws for
higher performance! - Ideal for store-front and curtain wall
construction!
Typical Applications
- Storefront & Curtain wall - Hurricane Shutter Framing -
Window Frames - Shelving & Racking - Impact Resistant Windows -
Wood to Concrete or CMU
Features Benefits Grade 5 dual-hardened heat treatment process
(Flex Technology®)
Virtual immunity to embrittlement failure & enhanced
ductility
Large, oversized fastener dimensions (Thread O.D., minor diameter
& unthreaded section)
Enhanced thread engagement, higher connection performance &
enhanced screw-anchor strength
Patented 40/45 V-Notched threads Higher strip-out resistance in
lower compression strength materials
Excellent corrosion resistance Multiple corrosion resistant
finishes
- Stalgard SUB: 2,000 hrs. exposure with no red rust
- Silver & White Stalgard: 1,000 hrs. exposure without red rust
(per ASTM B117)
Alpha-numeric length head-marking codes
Elco's Grade 5 dual-hardened head mark (Elco logo within
circle)
At inspection, ensures proper screw-anchor has been used
Drive & Head Styles HWH
Hex Washer Head TFH
Phillips Flat Head 2.75
2.75 2.75
Drive 3/8" Hex #3 Bit Drive #3 Bit Drive Washer Face Diameter
0.520" NA NA Head Diameter 0.400" 0.460" Head Height 0.240" 0.158"
0.210" Flare - 80 80
Corrosion Resistance Finish The #14 ConFlex masonry screws are
available in two excellent corrosion resistant coatings. The hex
head version is fully coated in Stalgard SUB. This coating resists
red rust for more than 2,000 hours salt spray exposure per ASTM
B117. The Flat and Trim head versions come with the standard
Stalgard coating and provide more than 1,000 hours of salt spray
exposure resistance per ASTM B117. All Stalgard finishes are RoHS
compliant (Chrome-Free).
#14 ConFlex® Grade 5 dual-hardened concrete / masonry screw
anchoring system
3
EL1017_single_pages.indd 3 3/15/16 7:28 AM
Installation 1. Determine embedment depth. Anchor embedment is the
distance from the tip of
screw to surface of the base material. Account for the fixture
thickness when selecting a screw length.
2. Drill a pilot hole with a standard ANSI 7/32" masonry drill bit
a minimum of 1/4" deeper than desired embedment.
3. Using an appropriately sized driver bit and impact wrench drive
the fastener into the pilot hole until flush with the
fixture.
DO NOT over drive the fastener.
The #14 ConFlex provides exceptional pull-out and shear values - a
significant advantage for lowering installation costs and long term
connection integrity
Performance Data Base Material Anchor
Embedment Distance Tension Capacity (Lbs.) Shear Capacity
(Lbs.)
Edge Spacing Ultimate Allowable Ultimate Allowable
Concrete (2,500 PSI)
1" 1-1/2" 1-1/2" 388 97 788 197 3" 708 177 876 219
3" 1-1/2" 432 108 1432 358 3" 788 197 1592 398
1-3/4" 1-1/2" 1-1/2" 1112 278 900 225 3" 1516 379 996 249
3" 1-1/2" 1236 309 1632 408 3" 1684 421 1816 454 6" 2244 561 1816
454
Concrete (3,500 PSI)
1" 1-1/2" 1-1/2" 508 127 1072 268 3" 924 231 1192 298
3" 1-1/2" 564 141 1948 487 3" 1028 257 2164 541
1-3/4" 1-1/2" 1-1/2" 1240 310 1132 283 3" 1692 423 1256 314
3" 1-1/2" 1380 345 2056 514 3" 1880 470 2288 572 6" 2504 626 2288
572
Concrete (6,000 PSI)
1" 1-1/2" 1-1/2" 672 168 1072 268 3" 1224 306 1192 298
3" 1-1/2" 748 187 1948 487 3" 1360 340 2164 541
1-3/4" 1-1/2" 1-1/2" 1488 372 1276 319 3" 2028 507 1420 355
3" 1-1/2" 1652 413 2324 581 3" 2256 564 2580 645 6" 3008 752 2580
645
Grouted CMU
1-3/4" 1-1/2" 1-1/2" 750 150 660 132 3" 1150 230 975 195
3" 1-1/2" 1250 250 1325 265 3" 1345 269 1730 346 6" 1420 284 2035
407
2-1/4" 1-1/2" 6" 2510 502 975 195 3" 6" 2950 590 2440 488
Hollow CMU 1" 1" 1" 390 78 270 54 2" 470 94 380 76
2" 1" 435 87 545 109 2" 520 104 760 152 3" 870 174 1085 217
Concrete Hollow Blocks 2000 PSI Normal Weight Concrete per ASTM
C-90 For each listed embedment, linear interpolation may be used
for intermediate spacing and edge distances. Indicated tension and
shear values listed were obtained in tests conducted at an
independent lab. These values have had an applied safety factor of
5:1 or 20% for CMU Data; 4:1 or 25% for Concrete Data (top table)
of the average ultimate value obtained. These reductions are
generally accepted practices for safe working loads; Note
additional reductions may be advisable based upon actual anchoring
conditions. It is always recommended to have a professional
engineer review anchoring conditions for long-term and safe
connections. Reference should always be made to applicable building
codes for specific safe allowable loads.
Grade 5 hardness zone for strength and ductility. #14 ConFlex
fasteners after Shear Test
Drill hole ANSI 7/32" diameter; minimum 1/4" deeper than anchor
embedment
Anchor embedment
Drive with impact wrench and driver bit.
Do NOT over drive.
ConFlex #14-6 Ordering information Part Number Length Head Style
Coating/Color Pkg. Qty.
EMR155 1-3/4" Hex Washer Head Stalgard SUB - Silver (2,000
hr)
1,000
EMR110 1-3/4" # 3 Phillips Flat Head Stalgard - Silver (1,000
hr)
2,000
EMR120 2-1/4" 1,500
EMR130 2-3/4" 1,000
EMR140 3-1/4" 1,000
EMR150 3-3/4" 500
EMR113 1-3/4" #3 Phillips Trim Flat Head Stalgard - Silver (1,000
hr)
2,000
1.500
EMR134 2-3/4" 1,000
EMR144 3-1/4" 1,000
Note: Length measured under head for hex head anchors, total length
for flat head and trim flat head anchors. See diagram above.
Drill Bit Drill Diameter Overall Length Usable Bit Length Drill Bit
Shank Type
EMC100 7/32" ANSI
4-1/2" 2-3/4" Tanged
EMC110 5-1/2" 4"
L L
Water Molecule
Free Hydrogen
Galvanic reaction occurs when dissimilar metals are in contact in
the presence of moisture
Aluminum Fixture (Anode)
Steel Screw (Cathode)
HASCC - Hydrogen Assisted Stress Corrosion Cracking
Why does HASCC occur? Free hydrogen atoms are generated in galvanic
reactions as a result of a dissimilar metal connection in the
presence of moisture. Free hydrogen atoms are also generated in
similar metal connections involving steel as the result of the
normal corrosion process.
Why is HASCC dangerous? The free hydrogen enters the fastener
through microscopic surface cracks. Providing the fastener has a
hardness equal to or greater than Rockwell C35 and is under stress
and / or load, the crystalline structure of the hardened steel is
broken down or split apart. As the propagation of the cracks in the
steel continues, the functional cross sectional area of the screw
is reduced significantly. Then, without notice, the screw's
remaining cross sectional area can not maintain the load that it is
under and sudden catastrophic failure occurs. This sequence can
occur within a day, days, months or years.
How is HASCC Controlled? Through the use of high quality steel
alloys and a heat treatment process that results in Grade 5
metallurgical properties, strength and significantly enhanced
ductility are achieved. It is the Grade 5 ductility that provides
virtual immunity to embrittlement failure.
Moisture H2O (Electrolyte)
701 E. Joppa Road, Towson MD 21286 Phone: 800-435-7213 (USA &
Canada) Fax: 800-738-9671 www.elcoconstruction.com ©2016 Elco
Construction Products. All Rights Reserved. Rev. 1/16 N464319
Proud Member of:
Elco®, Aggre-Gator®, Alumi-Flex™, Bi-Flex™, Crete-Flex®, ConFlex®,
Dril-Flex®, Drilltite®, Fab-Lok®, Flex Technology®, Flo-Seal®,
HangerMate®, Stalgard®, Tapfast®, Tap-Flex®, Topseal™, TrimFit®,
UltraCon® and Infastech® are trademarks of ElcoConstruction
Products. Avdel® is a registered trademark of Avdel UK Ltd.
AllFlex™ is a trademark of Alloy Fasteners, Inc. Dewalt® is a
registered trademark of The Black & Decker Corporation.
Scrubolt™ is a trademark of Butler Manufacturing Company. Pantone®
is a registered trademark of Pantone, Inc.
Warranty and Limitation of Liability:
All warranties of the Elco® products, expressed or implied,
including the warranties of merchantability and fitness for
particular purposes are specifically excluded for the following:
Elco will repair any product which, within twelve months after
sales by Elco Construction Products or its distributors, is found
by Elco to be defective in material or workmanship – normal wear
and tear excepted. This is the sole warranty of Elco Construction
Products and the sole remedy available to distributor or buyer.
Elco shall not be liable for any injury, loss of damage, direct,
incidental or consequential, arising from use of, or the inability
to use, any Elco product.
Elco Construction Products has strived for total accuracy
throughout this catalog. However, Elco Construction Products shall
not be liable or responsible for any typographical errors or
changes in product offering that may occur. If any questions arise
as to the accuracy of this catalog, please contact us at
1-800-435-7213.
6