40
RADIATION DETECTION SOLUTIONS MEDICAL | SCIENTIFIC | SOLUTIONS

InMed Radiation Detection Brochure 2013-14

Embed Size (px)

DESCRIPTION

 

Citation preview

Page 1: InMed Radiation Detection Brochure 2013-14

RADIATION DETECTION SOLUTIONS

MEDICAL | SCIENTIFIC | SOLUTIONS

Page 2: InMed Radiation Detection Brochure 2013-14

Welcome to InMedFor over 20 years, InMed has specialised in the supply and ongoing support of quality radiation detection equipment and accessories across Australia and New Zealand.

Our extensive range includes Hand-held Detectors, Portal and Area Monitors, Personal Dosimeters, Survey Meters, Counters and Probes. We represent various brands, including Atomtex, SE International Inc and Polimaster.

CONTENTS

4 PERSONAL DOSIMETERS

4 SE International The Sentry EC Dosimeter/Rate Meter

SE International Pen Dosimeter/Charger

SE International Rad-60 Personal Dosimeter

5 Polimaster PM1904 Polismart® II Radiation Detector

Polimaster PM1912 RadFlash®II Gamma Detector

Polimaster PM1203M Personal Dosimeter

6 Polimaster PM1208 / PM1208M Wrist Gamma Indicators

Polimaster PM1405 Survey Meter

Polimaster PM1603A / PM1603B Wrist Gamma Dosimeters

7 Polimaster PM1604A / PM1604B Personal Compact Dosimeters

Polimaster PM1610 / PM1610A Gamma Radiation Personal Dosimeters

8 Polimaster PM1621 / PM1621A / PM1621M / PM1621MA Gamma Radiation Personal Dosimeters

Atomtex AT3509/ AT3509A / AT3509B / AT3509C Personal Dosimeters

9 Atomtex AT2503 / AT2503A Personal Dosimeters

Atomtex Reader (RS232C interface)

Atomtex Reader (USB interface)

10 PERSONAL RADIATION DETECTORS

10 Polimaster PM1401GNA / PM1401GNB Radiation Detectors

Polimaster PM1401MA / PM1401MB

Polimaster PM1703GN / PM1703GNA / PM1703GNB

11 Polimaster PM1703M / PM1703MA /PM1703MB

Polimaster PM1703MO-1 / PM1703MO-2

12 HAND-HELD RADIATION DETECTORS

12 SE International Monitor 4 / 4EC

SE International Monitor 4USB / 4ECUSB

SE International MC1K Handheld Radiation Alert Detector

13 SE International Inspector Xtreme Hand-held Digital Radiation Alert Detector

SE International Inspector+ Hand-held Digital Radiation Alert Detector

SE International Inspector EXP+ Hand-held Digital Radiation Alert Detector

14 Polimaster PM1401K Multipurpose Hand-held Monitor

Polimaster PM1402M Portable Radiation Monitor

Polimaster PM1403 Multipurpose Radiation Monitor

15 Polimaster PM1701M Alarming Ratemeter

Polimaster PM1710A / PM1710GNA Hand-held Gamma and Gamma Neutron Monitors

Polimaster PM1710C / PM1710GNC Gamma and Gamma Neutron Monitors

16 Atomtex AT1103M X-Ray Radiation Dosimeter

Atomtex AT1121 / AT1123 X-Ray and Gamma Radiation Dosimeters

Atomtex AT1117M Portable Multifunction Radiation Monitor

17 Atomtex AT1125 / AT1125A Radiation Monitors

Atomtex AT6130 / AT6130A Radiation Monitor

Atomtex AT6130C Radiation Monitor

18 HAND-HELD RADIATION DETECTORS SMART PROBES

18 Atomtex Gamma Radiation Smart Probe BDKG-01

Atomtex X-Ray Smart Probe BDKR-01

Atomtex Gamma Radiation Smart Probe BDKG-02

Page 3: InMed Radiation Detection Brochure 2013-14

RADIATION DETECTION SOLUTIONS

www.inmed.com.au I 3

19 HAND-HELD RADIATION DETECTORS SOFTWARE

19 SE International Observer Software

SE International Sentry Software

SE International RadCalc Software

SE International RAD-60 ACS Express Software

20 HAND-HELD RADIATION DETECTOR ACCESSORIES

20 SE International Xtreme Boot

SE International Inspector Wipe Test Plate

SE International Rugged Case

SE International Carrying Cases

21 SE International RA-60 Carrying Case

SE International Inspector Stand

SE International Radiation Response Kit

22 SPECTROSCOPIC PERSONAL RADIATION DETECTORS

22 Polimaster PM1401K Hand-held Radionuclide Identifier

Polimaster PM1410 Radioisotope Identifier

Polimaster PM1401MB / PM1401GNB Gamma and Gamma Neutron Monitors

23 Polimaster PM1703MB / PM1703GNB Spectroscopic Personal Radiation Detectors

Polimaster PM1703MO-1A / PM1703MO-1B Personal Combined Radiation Detectors/Dosimeters

Polimaster РМ1704 / PM1704М / PM1704GN Spectroscopic Personal Radiation Detectors

24 Atomtex AT6101 / AT6101B Spectrometers

Atomtex AT6102 / AT6102A Spectrometers

SE International URSA-II Radiation Spectrum Analyser with URSA-II MCA Software

25 SE International Radiation Alert Gamma PAL Portable Analysis Lab

Atomtex AT1321 Spectrometer (Spectrometric Personal Radiation Detector)

26 SCINTILLATION & GM PROBES

26 SE International CDV-700RP Replacement Probes

SE International Rap-RS1 Replacement Probes

SE International Raps Scintillation Probes

SE International 1 X 1 and Larger Scintillation Probes

27 RADIATION SPECTROMETERS

27 Atomtex AT1315 Gamma Beta Radiation Spectrometer

28 ACTIVITY MONITORS

28 Atomtex AT1320 / AT1320A / AT1320B Gamma Activity Monitors

Atomtex AT1135 Portable Radiometric Laboratory

Atomtex AT1320A Gamma Activity Monitor

29 Atomtex AT1320C Gamma Activity Monitor

Atomtex AT1320M Gamma Activity Monitor

30 PORTABLE RADIATION SPECTROMETERS

30 Atomtex AT6101D Spectrometer

Atomtex AT6101DR Spectrometer

30 RADIATION ACTIVITY MONITORS

30 Polimaster PM1406

31 DOMESTIC SECURITY

31 Polimaster PM2010M

Polimaster PM2012M

Atomtex AT6101C Spectrometer (Spectrometric Portable Radiation Scanner)

32 RADIATION PORTAL MONITORS

32 Polimaster Railway Monitors

Polimaster Vehicle Monitors

Polimaster Pedestrian Monitors

33 Atomtex AT2327 Alarm Dosimeter / Radiation Monitor

34 STANDARD DOSIMETERS

34 Atomtex AT5350/1 Standard Dosimeter

34 AREA MONITORS

34 Atomtex AT2327 Alarm Dosimeter

Atomtex AT2327 Alarm Dosimeter with Data Display

35 WHOLE BODY COUNTERS

35 Atomtex AT1316 Whole Body Counter

Atomtex AT1322 and AT1322/1 Whole Boudy Counters

36 GAMMA BEAM IRRADIATORS AND CALIBRATION BENCHES

36 Atomtex AT-03 Calibration Stand

Atomtex UDG-AT110 Gamma Beam Irradiator with Calibration Bench

37 Atomtex UDG-AT130 Gamma Beam Irradiator with Calibration Bench

38 TERMS & CONDITIONS

Page 4: InMed Radiation Detection Brochure 2013-14

4 I www.inmed.com.au

SE INTERNATIONAL PEN DOSIMETER AND CHARGER

The SEI Pen direct reading dosimeter is a rugged, precision instrument.

It is higher quality and has greater reliability than other dosimeters of this type. It measures and directly reads accumulated dose (quantity of gamma and x-ray exposure).

• Measures and directly reads accumulated dose

• Sturdy metal clip

• Hermetically sealed

• Immersion proof

The SE International, Inc patented, handheld Charger can charge a variety of direct-reading dosimeters by simply squeezing the lever of a generator. The Charger requires no batteries. By pulling a trigger, a dosimeter is easily placed in or removed from the charger. The clamping action holds the dosimeter for you.

PEN DOSIMETER

Product Code Description

SEIpendose Pen Dosimeter

SEIpencharge Pen Charger

SE INTERNATIONAL THE SENTRY EC DOSIMETER/RATE METER

The Radiation Alert® Sentry EC is a personal alarming dosimeter/ratemeter designed to ensure the safety of personnel that work in occupations with potential x-ray or gamma exposure.

The pocket sized unit has an energy compensated tube for a linear response to gamma and built in memory for recording data points for tracking accumulated exposure.

The SentryCom Software option enables you to generate incident reconstruction for analysis and easily program the desired alert levels for dose and dose rate.

• Measures and reads accumulated dose

• Small size with sturdy metal clip

• Hermetically sealed and immersion proof

THE SENTRY EC DOSIMETER/RATE METER

Product Code Description

SEIsentry Sentry Radiation Monitor

SEIsentsof Sentry Software (Includes serial cable)

SE INTERNATIONAL RAD-60 ALARMING PERSONAL DOSIMETER

The RADOS RAD-60 Personal Alarm Dosimeter is a programmable and reliable instrument for everyday radiation monitoring, ensuring the personal safety of the user.

• Reliable detection and registration of gamma radiation and x-rays

• User selectable alarm levels for both dose and dose rate

• Detector system utilizes high quality energy compensated

• Si-diode and advanced mathematical dose rate linearisation

• Splash-proof construction, high impact plastic case with strong pocket clip

RAD-60 ALARMING PERSONAL DOSIMETER

Product Code Description

SEIRAD60 Rados RAD60

SEIrad60cc RAD60 Carry Case

PERSONAL DOSIMETERS

Page 5: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 5

POLIMASTER PM1203M PERSONAL DOSIMETER

The PM1203M is multipurpose professional Geiger-Muller counter dosimeter designed for continuous monitoring of the gamma radiation environment, as well as for search for the ionizing radiation sources.

A simple and reliable dosimeter for a wide range of applications.

• Easy to use, 2 button operation

• Lightweight and small

• Measurement data storage in non-volatile memory

• IR interface, IRDA compatible

• Audible and visual alarms

• LCD display

• One year battery life

• Shockproof sealed cas with belt-clip

• Dose rate range: 0.01 - 2000 ~Sv /h

• Dose range: 0.001 - 9999 mSv

• Energy range: 0.06 - 1.5 MeV

PM1203M PERSONAL DOSIMETER

Product Code Description

POLPM1203M PM1203M Belt Clip Gamma Dosimeter - Programmable

POLIMASTER RADIATION DETECTOR POLISMART® II PM1904

The new-trend networked Polismart® II PM1904 gamma detector is a small and efficient add-on for iPhone®.

It allows iPhone® users to continuously monitor environmental radiation background and individual radiation exposure.

Polismart® II PM1904 is a must-have radiation detection device for everyone who is looking for protection from radiation threat and minimization of the negative radiation impact.

Radiation detector PM1904 can operate without iPhone® as independent unit.

When preset thresholds are exceeded, device provides LED light alarm. All measurements are recorded in non-volatile memory.

• Dose rate range: 0.0 1 ~Sv /h - 13 mSv /h

• Dose range: 1 ~Sv- 10 Sv

• Energy range: 0.06 - 1.33 MeV

PM1904 RADIATION DETECTOR POLISMART® II

Product Code Description

POLPM1904 Radiation Detector Polismart® II PM1904

POLIMASTER GAMMA DETECTOR PM1912 RADFLASH®II

Compact and sensitive Gamma Detector PM 1912 RadFlash®II designed in the form of USB flash drive with networked software package Flash Radiation Monitor™.

It is intended to be used by everyone. The range of tasks includes control of cumulative individual radiation dose, radiation background monitoring and alarm of a user about getting into the zone with high levels of gamma radiation and user’s access to geo information system of the radiation measurement.

• Dose rate range: 0.1 ~Sv /h - 10 mSv /h

• Dose range: 1 ~Sv- 10 Sv

• Energy range: 0.06 - 1.33 MeV

GAMMA DETECTOR PM1912 RADFLASH®II

Product Code Description

POLPM1912 Gamma Detector PM1912 RadFlash®II

PERSONAL DOSIMETERS

Page 6: InMed Radiation Detection Brochure 2013-14

6 I www.inmed.com.au

PERSONAL DOSIMETERS

POLIMASTER PM1208/PM1208M WRIST GAMMA INDICATOR

The PM1208 Wrist Gamma Indicator is a stylish combination of gamma detector and a Swiss-made quartz watch.

It that continuously monitors environmental radiation levels and alerts user in case of danger with an audible alarm. The PM1208 and PM1208M instruments are water-resistant up to 100 meters and are ideal for industry professionals and the general public alike.

• Dose rate range: om -9999.99 ~Sv/h

• Dose range: 0.001 - 9999 mSv

• Energy range: 0.06 - 1.5 MeV

PM1208M WRIST GAMMA INDICATOR

Product Code Description

POLPM1208 PM1208 Wrist Gamma Indicator Stainless Steel

POLPM1208M PM1208M Wrist Gamma Wrist Watch with IR link

POLIMASTER PM1603A/PM1603B WRIST GAMMA DOSIMETERS

The PM1603A and PM1603B are professional wrist dosimeters for automatic control of radiation environment and measurement of the ambient dose and dose rate in a wide range.

Recommended for use in the extreme environments.

• Dose rate range: 0.0 1 ~Sv /h - 6.50 Sv /h (PM 1603AjPM 1604A) 0.01 ~Sv/h - 13 Sv/h (PM1603B/PM1604B)

• Dose range: 0.01 ~Sv - 9.99 Sv

• Energy range: 0.048 - 6.0 MeV

• Operating temperature: -20C up to +70C

PM1604 PERSONAL COMPACT DOSIMETER

Product Code Description

POLPM1604A PM1604A Compact Personal Dosimeter with IR Link

POLPM1604B PM1604A Compact Personal Dosimeter with IR Link

POLIMASTER SURVEY METER PM1405

The Polimaster model РМ1405 is a compact multifunction survey meter, capable of measuring X-ray, gamma and beta radiation.

The PM1405 is designed for the wide range of radiation safety applications and may be successfully used by radiation control services personnel, first responders, employees of security service and customs, as well as personnel whose work includes solving problems of local gamma and beta radiation sources detection or single objects contaminated by gamma and/or beta radiation sources.

• Ƴ- and x-ray radiation dose rate measurement range: 0.1μSv/h - 100mSv/h

• B-flux density measurement range: 10 - 103 min-1cm2

• Energy range: 0.05 - 3.0MeV

• Operating temperature: -10 up to +50°C

PM1405 SURVEY METER

Product Code Description

POLPM1405 Survey Meter

Page 7: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 7

PERSONAL DOSIMETERS

POLIMASTER PM1604A/PM1604B PERSONAL COMPACT DOSIMETERS

Polimaster’s PM1604A and PM1604B models are energy-compensated personal pocket- sized dosimeters.

The PM1604A and PM1604B measure personal dose equivalent Hp(10) and personal dose equivalent rate Hp(10) of both gamma and X-ray radiation.

• Dose rate range: 0.0 1 ~Sv /h - 6.50 Sv /h (PM 1603AjPM 1604A) 0.01 ~Sv/h - 13 Sv/h (PM1603B/PM1604B)

• Dose range: 0.01 ~Sv - 9.99 Sv

• Energy range: 0.048 - 6.0 MeV

• Operating temperature: -20C up to +70C

PM1604 PERSONAL COMPACT DOSIMETER

Product Code Description

POLPM1604A PM1604A Compact Personal Dosimeter with IR Link

POLPM1604B PM1604A Compact Personal Dosimeter with IR Link

POLIMASTER CONTINUOUS, PULSE X-RAY AND GAMMA RADIATION PERSONAL DOSIMETER PM1610/PM1610A

The PM1610/PM1610A are professional personal dosimeters for measuring continuous and pulse X-Ray and Gamma Radiation in the energy range 20 keV – 10 MeV.

The PM1610 and PM1610A dosimeters are recommended to protect professionals, who work with or around X-ray or gamma radioactive materials, including hospital staff, miners, customs officers and nuclear stations personnel. There are four colours to choose from including orange, grey, blue and black.

PM1610 PERSONAL DOSIMETERS

Product Code Description

POLPM1610 PM1610 Gamma Radiation Personal Dosimeter

POLPM1610A PM1610A Gamma Radiation Personal Dosimeter

Page 8: InMed Radiation Detection Brochure 2013-14

8 I www.inmed.com.au

ATOMTEX AT3509 SERIES PERSONAL DOSIMETERS

The Atomtex AT3509 series of Personal Dosimeters is a modern wide-range accurate microprocessor instrument used to control personal dose equivalent Hp(10) and Hp(0.07) and dose rate.

When connected to a PC, the reader can be a part of an efficient automatic system for monitoring staff radiation exposure.

• Silicone planar detector

• Compensating filter and electrical energy dependence correction

• Zero intrinsic background

• Repeating impact protection

• Parameter self-check

• Resistance to impacts and vibration, dust-and-moisture-proof, tolerance to electromagnetic interference

AT3509 SERIES PERSONAL DOSIMETERS

Product Code Description

ATO14 Personal dosimeter AT3509

ATO15 Personal dosimeter AT3509A

ATO16 Personal dosimeter AT3509B

ATO17 Personal dosimeter AT3509C

ATO12a Reader/Software for PC data exchange AT3509

PERSONAL DOSIMETERS

POLIMASTER PM1621 SERIES X-RAY/GAMMA RADIATION PERSONAL DOSIMETERS

Polimaster’s PM1621 and PM1621A Personal X-ray and Gamma Radiation Dosimeters are professional energy-compensated instruments.

These dosimeters monitor and measure the personal dose equivalent Hp(10) and personal dose equivalent rate Hp(10) from both gamma and X-ray radiation. Their ability to compensate for the energy variations in the range from 10 keV up to 20MeV allows these personal dosimeters to make extremely accurate measurements.

Dose rate range PM1621/PM1621M: 0.1μSv/h - 0.2Sv/h PM1621A/PM1621MA: 0.1μSv/h - 2.0Sv/h

Dose range 0.01μSv - 9.99Sv

Energy range 0.01 - 20MeV

Operating temperature -40 up to +60°C

PM1405 SURVEY METER

Product Code Description

POLPM1621 PM1621 Belt Clip Gamma/ X-Ray Dosimeter with IR Link

POLPM1621A PM1621A Belt Clip Gamma/ X-Ray Dosimeter with IR Link

POLPM1621 PM1621M Belt Clip Gamma/ X-Ray Dosimeter with IR Link

POLPM1621MA PM1621MA Belt Clip Gamma/ X-Ray Dosimeter with IR Link

Page 9: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 9

ATOMTEX AT2503 SERIES PERSONAL DOSIMETERS

The AT2503 is an easy to operate, pocket-sized microprocessor instrument with high accuracy and reliability.

When connected to a PC, the reader can be a part of an efficient automatic system for monitoring staff radiation exposure.

AT2503 SERIES PERSONAL DOSIMETERS

Product Code Description

ATO12 Personal Dosimeter AT2503

ATO13 Personal Dosimeter AT2503A

PERSONAL DOSIMETERS

ATOMTEX READER (RS232C INTERFACE)

The Atomtex Reader is intended to connect personal dosimeters series AT2503 and AT3509 to PC and provides their operation in the dosimetry control system.

The reader provides data exchange of dosimeters and PC by infrared channel transforming optical signals into standard electrical ones for interface.

The reader is a metal enclosure with support and special pocket, in which the clamp is inserted until bumping in order to connect a dosimeter. The cable with socket type DB-9F is used to connect the reader to a free COM-port.

READER (RS232C INTERFACE)

Product Code Description

ATO12a Reader (RS232C interface)

ATOMTEX READER (USB INTERFACE)

The Atomtex Reader is intended to connect personal dosimeters series AT2503 and AT3509 to PC and provides their operation in the dosimetry control system.

The reader provides data exchange of dosimeters and PC by infrared channel transforming optical signals into standard electrical ones for interface.

The reader is a enclosure with support and special pocket, in which the clamp is inserted until bumping in order to connect a dosimeter. The cable with socket is used to connect the reader to a USB-port.

READER (USB INTERFACE)

Product Code Description

ATO12a Reader (USB Interface)

Page 10: InMed Radiation Detection Brochure 2013-14

10 I www.inmed.com.au

PERSONAL RADIATION DETECTORS

POLIMASTER PM1401GNA / GNB PERSONAL RADIATION DETECTORS

The gamma-neutron personal radiation detectors allow searching and detecting radioactive and nuclear materials including weapon grade materials.

Gamma (PM1401MB) and gamma-neutron (PM1401GNB) spectroscopic personal radiation detectors are designed to detect, locate and identify radiation sources under difficult working conditions.

Their external hidden vibration alarm makes these instruments ideal for inconspicuous inspections and use in noisy places.

PM1401GNA / GNB PERSONAL RADIATION DETECTORSProduct Code Description

POLPM1401GNA PM1401GNA Personal Radiation Detector

POLPM1401GNB PM1401GNB Personal Radiation Detectors

POLIMASTER PM1401MA / MB PERSONAL RADIATION DETECTORS

The Polimaster PM1401MA / MB are highly sensitive personal gamma radiation detectors, especially designed to operate in the harsh environment.

The detectors are used both for search of the radiation and nuclear materials and evaluation of the radiation level.

PM1405 SURVEY METER

Product Code Description

POLPM1401MA PM1401MA Personal Radiation Detectors

POLPM1401MB PM1401MB Personal Radiation Detectors

POLIMASTER PM1703GN/ GNA / GNB PERSONAL RADIATION DETECTORS

Polimaster’s gamma-neutron personal radiation detectors PM1703GN and PM1703GNA are designed to detect the slightest amounts of the gamma and neutron radiation emitting materials.

The instruments are equipped with a CsI(Tl) (for gamma detection) and a LiI(Eu) (for neutron detection) scintillation detectors to alert the user that the radiation levels have exceeded the preset threshold values.

PM1703GN/ GNA / GNB PERSONAL RADIATION DETECTORSProduct Code Description

POLPM1703GN PM1703GN Alarming Ratemeter - Gamma/Neuton IR Data

POLPM1703GNA PM1703GNA Alarming Ratemeter with Vibration Alert

POLPM1703GNB PM1703GNB Alarming Ratemeter - Gamma/Neuton with Bluetooth

POLPM1621MA PM1621MA Belt Clip Gamma/ X-Ray Dosimeter with IR Link

Page 11: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 11

PERSONAL RADIATION DETECTORS

POLIMASTER PM1703MO-1 AND PM1703MO-2 PERSONAL COMBINED RADIATION DETECTORS/DOSIMETERS

The Polimaster PM1703MO-1 and PM1703MO-2 instruments combine features of both Personal Radiation Detector (PRD) and Dosimeter in the one housing.

Each instruments is equipped with two detection modules: their highly sensitive CsI(Tl) scintillation detector allows for searching of the radioactive and nuclear materials and together with small-sized GM tube detector allows for measuring dose rate of gamma radiation in the wide energy range.

PM1703MO-1 AND PM1703MO-2 PERSONAL COMBINED RADIATION DETECTORS/DOSIMETERSProduct Code Description

POLPM1703MO-1 PM1703MO-1

POLPM1703MO-2 PM1703MO-2

POLIMASTER PM1703M / MA / MB PERSONAL RADIATION DETECTORS

Polimaster’s Personal Radiation Detectors PM1703M and PM1703MA are designed to detect and locate even the slightest traces of the radioactive and nuclear materials.

The instruments’ two operating modes enable the user both search for gamma radiation sources based on the intensity of the emitted radiation and evaluate the radiation level.

The instrument provides two operating modes: search for the gamma radiation sources and evaluation of the radiation level in mSv/h or mR/h.

PM1703M/MA/MB PERSONAL RADIATION DETECTORSProduct Code Description

POLPM1703M PM1703MPOLPM1703MA PM1703MAPOLPM1703MB PM1703MB

Page 12: InMed Radiation Detection Brochure 2013-14

12 I www.inmed.com.au

SE INTERNATIONAL INSPECTOR XTREME HANDHELD DIGITAL RADIATION ALERT® DETECTOR

The Inspector Xtreme offers maximum performance in a lightweight, rugged solution for using your survey meter in the field.

The Inspector Xtreme is designed specifically for individuals operating in tough environments, such as 1st Responders, miners, and HAZMAT crews.

The unit is a small, handheld, microprocessor-based instrument which offers excellent sensitivity to low levels of alpha, beta, gamma, and x-rays.

The digital readout is displayed with a red count light and a beeper sounds with each count detected. Other features include an adjustable timer, external calibration controls, and selectable alert.

INSPECTOR XTREME HANDHELD DIGITAL RADIATION ALERT® DETECTORProduct Code Description

SEIinspext Inspector Xtreme Handheld Digital Radiation Alert® Detector

SE INTERNATIONAL INC. MONITOR 4 / 4EC HANDHELD RADIATION ALERT® DETECTOR

The M4 and M4EC are compact, ergonomic, general purpose survey meters capable of detecting alpha, beta, gamma, and x-rays over 3 selectable ranges.

A red count light flashes and a beep sounds with each event detected. The Monitor 4EC offers a more linear reading for gamma and x-rays (above 40 keV).

The USB Version of the Observer software runs on a Windows® platform and can be used with the Monitor 4 USB & Monitor 4EC USB Radiation Detectors.

The Observer USB reads in Counts, CPM, and CPS, as well as µR/hr, mR/hr, and µSv/hr and has the ability to collect, log, and perform statistical analysis on the data received. The USB version is shipped with the USB versions of the previously mentioned units. (See Observer Software)

MC1K HAND HELD RADIATION MONITOR

Product Code Description

SEImon4 Monitor 4

SEImon4k Monitor 4 Kit

SEImon4usb Monitor 4 with USB and Observer Software

SEImon4GMT Monitor 4 GM Tube

SEImon4EC Monitor 4EC

SEImon4ecusb Monitor 4EC with USB and Observer Software

HAND-HELD RADIATION DETECTORS

Page 13: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 13

SE INTERNATIONAL INC. INSPECTOR+ HANDHELD DIGITAL RADIATION ALERT® DETECTOR

Now with a settable alert, the SE International Inc. Inspector+ is a small, handheld, microprocessorbased instrument which offers excellent sensitivity to low levels of alpha, beta, gamma, and x-rays.

The digital readout is displayed with a red count light and a beeper sounds with each count detected. Other features include an adjustable timer, external calibration controls and a settable alert.

INSPECTOR HANDHELD DIGITAL RADIATION ALERT DETECTORProduct Code Description

SEIinsp+ Inspector+ Handheld Digital Radiation Alert® Detector

SE INTERNATIONAL INC. MC1K HANDHELD RADIATION ALERT® DETECTOR

The new ergonomic MC1K is a handheld survey meter using a built-in energy compensated GM detector.

• Detects gamma and x-rays up to 1000 mR/hr over 4 selectable ranges

• A beep sounds and a count light flashes with each event detected

MC1K HAND HELD RADIATION MONITOR

Product Code Description

SEIMC1K MC1K Hand Held Radiation Monitor

HAND-HELD RADIATION DETECTORS

SE INTERNATIONAL INSPECTOR EXP+ HANDHELD DIGITAL RADIATION ALERT® DETECTOR

Now with a settable alert, the Inspector EXP+ offers excellent sensitivity to low levels of alpha, beta, gamma, and x-rays.

• The digital readout is displayed with a red count light and a beeper sounds with each count detected

• Same small size, as the Inspector with the added versatility of an external probe

• Carrying case has a clear window panel providing full view of the readout, count light, access to the switches, and a convenient belt loop for carrying the instrument

INSPECTOR EXP+ HANDHELD DIGITAL RADIATION ALERT DETECTORProduct Code Description

SEIinsp+ext Inspector EXP+ with external pancake probe

Page 14: InMed Radiation Detection Brochure 2013-14

14 I www.inmed.com.au

POLIMASTER PM1401K MULTI PURPOSE HAND HELD MONITOR

Polimaster’s PM1401K Multipurpose Radiation Monitor designed for adequate detection of the alpha, beta, gamma and neutron radiation sources as well as for gamma spectra accumulation and precise measuring of gamma dose rate and levels of contamination of surfaces, contaminated with alpha and beta irradiating sources.

The PM1401K can also:

• Measure precisely the dose rate

• Alert users of the presence of a radiation source via audible and vibrating alarms

• Record and store up to 500 event and 100 gamma spectra in its non-volatile memory

• Transmit all of the recorded data to a PC via an IR channel

PM1401K MULTI PURPOSE HAND HELD MONITORProduct Code Description

POLPM1401K PM1401K Multi Purpose Hand Held Monitor

POLIMASTER PM1402M PORTABLE RADIATION MONITOR

The PM1402 is a portable multipurpose radiation laboratory which incorporates a central processing unit and five external exchangeable radiation detectors.

It can be used for detection and measurement of the alpha, beta, gamma and neutron radiation and gamma spectrum accumulation.

PM1402M PORTABLE RADIATION MONITOR

Product Code Description

POLPM1402M PM1402M Multipurpose Portable Radiation Monitor

HAND-HELD RADIATION DETECTORS

POLIMASTER PM1403 MULTIPURPOSE RADIATION MONITOR

Multifunctional, networked mobile monitor for measuring all types of ionizing radiation and spectrum collection of gamma emitting sources.

The device is equipped with a built-in CsI(TI) detector for the detection and location of gamma radiation sources and reliable identification of radioisotopes. In addition, the device has four external interchangeable modules for the detection of alpha, beta, gamma and neutron radiation.

The instrument provides fast and reliable identification of radioisotopes and can transmit measured radiological data and geographic coordinates to the Remote Expert Center of the Polimaster Nuclear Protection Network system (Polimaster NPNET™) via buit-in GSM/GPRS modules.

PM1402M PORTABLE RADIATION MONITOR

Product Code Description

POLPM1402M PM1402M Multipurpose Portable Radiation Monitor

Page 15: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 15

POLIMASTER PM1701M ALARMING RATEMETER

The Polimaster PM1701M Alarming Ratemeter is a held-held gamma monitor for detection of the radiation sources in difficult-to-access places, harsh environments and noisy areas.

The PM1701M is widely used to inspect vehicles with scrap metal and waste materials. The alarming ratemeter features a shockproof gamma sensitive radiation detection module attached to a telescopic extension tube.

The PM1701M performs the following functions:

• Detects gamma radiation sources, even when they are shielded

• Alerts the user of the presence of a radiation source through an audible alarm

• Records and stores data for up to 1000 events in the instruments’ non-volatile memory

• Transmits all recorded data to a PC via IR channel for the data processing and analysis

PM1701M ALARMING RATEMETER

Product Code Description

POLPM1701M PM1701M Alarming Ratemeter

POLIMASTER PM1710A / GNA HAND-HELD GAMMA AND GAMMA-NEUTRON MONITORS

The PM1710A gamma and PM1710GNA gamma-neutron monitors have the highest sensitivity among the family of the Polimaster’s hand-held search instruments.

They are ideally suited for fast search and detection of traces of radioactive and nuclear materials.

PM1710A/GNA HAND-HELD GAMMA AND GAMMA-NEUTRON MONITORSProduct Code Description

POLPM1710A PM1710A Hand-Held Gamma Monitor

POLPM1710GNA PM1710GNA Hand-Held Gamma-Neutron Monitor

POLIMASTER PM1710C GAMMA/PM1710GNC GAMMA-NEUTRON MONITORS

The wall-mounted PM1710C Gamma and PM1710GNC Gamma-Neutron monitors are highly sensitive instruments designed for radiation monitoring and thus protection of a building against radioactive contamination.

The detectors may be fixed near doorways and facility entrances to continuously monitor human traffic and their luggage against radioactive sources presence.

PM1710C GAMMA AND PM1710GNC GAMMA-NEUTRON MONITORSProduct Code Description

POLPM1710C PM1710C Gamma Monitor

POLPM1710GNC PM1710GNC Gamma-Neutron Monitors

HAND-HELD RADIATION DETECTORS

Page 16: InMed Radiation Detection Brochure 2013-14

16 I www.inmed.com.au

ATOMTEX AT1103M X-RAY RADIATION DOSIMETER

Unique highly-sensitive devise for measuring radiation exposure on crystalline lens, mucus membranes and skin.

Measures directed dose equivalent rate of continuous X-ray radiation with energy from 5 keV.

AT1103M X-RAY RADIATION DOSIMETER

Product Code Description

ATO3 AT1103M X-RAY Radiation Dosimeter

ATOMTEX AT1121, AT1123 X-RAY AND GAMMA RADIATION DOSIMETERS

Portable multifunctional wide-range instruments for continuous, short-term and pulsed X and gamma radiation dosimetry.

• Tissue-equivalent detector - scintillation plastic with heavy metal additive

• Measurement of short-term (from 30 ms - AT1121) and impulse (from 10 ns AT1123) radiation

• Exposure time assessment

• Large dedicated digital/analogue LCD screen with backlighting

• Integrated system for LED measurement path stabilization

• Sound and visual alarm in case threshold level is exceeded

• External control panel can be used for remote measurement

• Fixed installation is possible with alarm dosimeter functionality and remote control from the distance of up to 25 m

• Three types of power sources

• Severe operating conditions

AT1121, AT1123 X-RAY/GAMMA RADIATION DOSIMETERS

Product Code Description

ATO1 AT1121 Radiation Dosimeter

ATO2 AT1123 Radiation Dosimeter

ATOMTEX AT1117M PORTABLE COMBINED MULTIFUNCTION RADIATION MONITOR

The AT1117M is designed for measuring X-ray, gamma and neutron radiation ambient dose equivalent rate and ambient dose equivalent, density of alpha and beta radiation flux from contaminated surfaces, radiation surface activity and neutron radiation flux density.

• Smart probes (RS232)

• Built-in LED stabilisation system

• Audible and visual alarm at dose, dose rate and flux density threshold exceeding

• Wide temperature operating range

• Large backlit LCD

• Log and transfer up to 100 measurements to PC

• Two alternative processing units

AT1117M PORTABLE COMBINED MULTIFUNC-TION RADIATION MONITORProduct Code Description

ATO6 AT1117M Portable combined multifunction radiation monitor

HAND-HELD RADIATION DETECTORS

Page 17: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 17

ATOMTEX AT1125 AND AT1125A RADIATION MONITORS

Portable high sensitive radiation monitors intended to search and detect gamma radiation sources, measure ambient gamma radiation dose equivalent rate and alpha and beta radiation flux density from contaminated surfaces and estimate 137Cs specific activity in environmental samples.

• Alarm at threshold exceeding

• Special large backlit LCD

• 256-channel MCA

• Log and transfer measurement results to PC

• Built-in LED stabilisation system of the measuring path providing no need to use a reference source

• Store up to 100 measurement results in the instrument memory

• Scrap metal radiation monitoring

• Specific activity measuring under field conditions as an option

• Three power types

AT1125 RADIATION MONITORS

Product Code Description

ATO4 AT1125 Radiation Monitor

ATO5 AT1125A Radiation Monitor

ATOMTEX AT6130 AND AT6130A RADIATION MONITOR

The Compact AT6130 and AT6130A are Radiation Monitors intended for ambient dose equivalent rate and ambient gamma and X-radiation dose equivalent rate measurement.

It is also used for measurement of beta particle flux density on contaminated surfaces. In search mode it measures count rate in counts per second.

The AT6130A has two variants:

• Without PC communication interface

• With Bluetooth interface

AT6130 RADIATION MONITOR

Product Code Description

ATO7 AT6130 Radiation Monitor

ATOMTEX AT6130C RADIATION MONITOR

Compact reasonably priced device intended for ambient dose equivalent rate and ambient gamma radiation dose equivalent rate measurement.

• Low weight and small size

• Automatic compensation of intrinsic detector background

• Sound and visual alarm in case threshold level is exceeded for dose and dose rate

AT6130C RADIATION MONITOR

Product Code Description

ATO11 AT6130C Radiation Monitor

HAND-HELD RADIATION DETECTORS

Page 18: InMed Radiation Detection Brochure 2013-14

18 I www.inmed.com.au

HAND-HELD RADIATION DETECTORSSMART PROBES

ATOMTEX GAMMA RADIATION SMART PROBE BDKG-01

Wide-range gamma radiation smart probe to measure ambient dose equivalent and dose equivalent rate gamma radiation in energy range 60 keV – 3 MeV up to 10 Sv/h (10 Sv).

• Wide-range measuring range of ambient dose equivalent and dose equivalent rate gamma radiation

• The smart probe BDKG-01 has RS232 interface

• Can be placed in a hermetic counter to be submerged

• Dust and splash-proof case

GAMMA RADIATION SMART PROBE BDKG-01

Please contact us for more information when ordering this product.The smart probe BDKG-01 may be included in to complete set of radiation monitor AT1117M or work independently in real terms being con-nected to the PC.

ATOMTEX GAMMA RADIATION SMART PROBE BDKG-02

Wide-range gamma radiation smart probe to perform environmental and area radiation monitoring of radiation-sensitive rooms and targets.

• Measure ambient dose equivalent rate gamma radiation in energy range 60 keV – 3 MeV up to 10 Sv/h.

• Wide-range measuring range of dose equivalent rate gamma radiation

• The smart probe BDKG-02 has RS485 interface

• Dust and splash-proof case

GAMMA RADIATION SMART PROBE BDKG-02

Please contact us for more information when ordering this product.The smart probe BDKG-02 may be include in to complete set of alarm dosimeter AT2327 (automated radiation monitoring system) or work independently in real terms being connected to the PC.

ATOMTEX X-RAY SMART PROBE BDKR-01

The BDKR-01 is a unique highly-sensitive smart probe used to control dose burden of crystalline lens, mucous membranes and skin. It measures directional dose equivalent rate of continuous x-ray radiation with the energy from 5 keV.

• X-ray source search

• Fast response to radiation background change

• The smart probe BDKR-01 has RS232 interface

• Keeping up to 500 measuring spectra in the smart probe nonvolatile memory and transferring them to PC

The smart probe has scintillation NaI (Tl), ø 9x2 mm, with beryllium window as a x-ray radiation detector. The measuring method of directional dose equivalent rate is based on measuring the instrument spectrum and its interval standardized weighing per a dose rate unit. The relevant energy response correction for the count rate mode is also provided.

GAMMA RADIATION SMART PROBE BDKG-02

Please contact us for more information when ordering this product.The smart probe BDKR-01 may be include in to complete set of radiation monitor AT1117M or work independently in real terms being connected to the PC.

Page 19: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 19

HAND-HELD RADIATION DETECTORSSOFTWARE

SE INTERNATIONAL OBSERVER SOFTWARE

The Observer software runs on a Windows platform and can be used with the Inspector, Digilert, Geiger, and Monitor 4 Radiation Detectors.

As an option, any of our Radiation Alert® instruments can be modified to interface with the Observer. The Observer reads in Counts, CPM, and CPS and has the ability to collect, log, and perform statistical analysis on the data received. The data is displayed on a graph as well as digital and analog on-screen meters and can be saved or printed in various ways including a spreadsheet format.

The dwell/count time can be adjusted for each point on the graph. You can also set the length of time for the count. The on-screen meters in the software have adjustable settings as well as a settable alarm in CPM. There are both visual and audio indicators, and you can play the meter click through your PC speakers.

OBSERVER SOFTWARE

Product Code Description

SEIobserver Observer Software

SE INTERNATIONAL SENTRYCOM SOFTWARE

The Windows® based SentryCom Software enables you to set the values for dose and dose rate alarms and warnings, set the Cal Factor, and the data logging frequency.

It also allows the user to download the accumulated exposure data, which includes time and date stamp, exposure, and power cycle identifiers for analysis. The data is stored in a convenient delimited text file for use with a spreadsheet program.

SENTRY SOFTWARE

Product Code Description

SEIsentsof Sentry Software includes serial cable

Page 20: InMed Radiation Detection Brochure 2013-14

20 I www.inmed.com.au

SE INTERNATIONAL RUGGED CASE

Ideal for military applications, this is the ultimate case for protection from severe weather, drops, and more. Made from a nearly indestructible material, it has been designed to house your Inspector+ in a dustproof, air proof, and watertight case while still providing you with access to your Inspector+ for data, regardless of the conditions (Gamma detection only).

RUGGED CASE

Please contact us for more information when ordering this product.

SE INTERNATIONAL WIPE TEST PLATE FOR INSPECTOR

The stainless steel WipeTest Plate slides easily onto the Inspector positioning the depression and wipe directly in front of the GM tube window at a fixed distance of 1cm.

The WipeTest plate is removable for general surveying. (patent #5,936,246) Many of the customers using the Inspector Wipe Test Plate also use it as a Beta Shield for the 2-inch GM detector. (patent# 5,936,246)

WIPE TEST PLATE FOR INSPECTOR

Product Code Description

SEIinswtp Wipe Test Plate for Inspector Only

HAND-HELD RADIATION DETECTOR ACCESSORIES

SE INTERNATIONAL CARRYING CASES

Carrying case included with models, Inspector, Inspector EXP, Digilert 50 & 100, M4, M4EC, M5, and MC1K. Carrying cases are equipped with belt clip or belt loop. Carrying Case for Inspector Xtreme, Digilert 100 Xtreme, and URSA-II Models provides ease of mobility and splash protection.

CARRYING CASES

Please contact us for more information when ordering this product.

SE INTERNATIONAL XTREME BOOT FOR INSPECTOR / DIGILERT / GEIGER MODELS

The Xtreme boot offers maximum performance in a lightweight rugged solution for using Radiation Alert® products in the field.

Made of a RoHS compliant TPE rubber, the case also offers superior grip and drop protection. When using the pancake detector, a protective door opens on the back of the case exposing the end window of the GM for alpha detection. The Xtreme boot is designed for use with the Inspector, and Digilert handheld radiation detectors.

CARRYING CASES

Product Code

Description

SEIxpb Inspector Xtreme Rubberized Boot / Carrying Case

Page 21: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 21

SE INTERNATIONAL XTREME DASHMOUNT

Use the dashmount for easy access to your radiation detection instruments upon arriving on the scene.

The 2 inch suction cup offers a rugged mounting solution to almost any dashboard surface. The Xtreme Dashmount also offers to ability to monitor hands free to check for contamination of your person or items. Suction and handlebar mounts available.

XTREME DASHMOUNT

Please contact us for more information when ordering this product.

HAND-HELD RADIATION DETECTOR ACCESSORIES

SE INTERNATIONAL RADIATION ALERT® RESPONSE KIT

The Radiation Alert Response Kit is a customizable response kit that can be configured to fit the needs of your response team. It includes a hard shell, watertight case with a shock absorbent foam interior for safe storage and transportation of a variety of first responder instruments.

RADIATION ALERT® RESPONSE KIT

Please contact us for more information when ordering this product.

SE INTERNATIONAL STAND FOR INSPECTOR, DIGILERT AND GEIGER MODELS

Whether you need to perform area monitoring or scan your hands and items for contamination, the stand offers a convenient way for the instrument to stand vertically while leaving your hands free for other tasks.

• Made from polished stainless steel

• Double stick adhesive strips are included to mount the stand in a permanent location

• Fits in the carrying case with the instrument

STAND FOR INSPECTOR, DIGILERT AND GEIGER MODELSPlease contact us for more information when ordering this product.

SE INTERNATIONAL INC. RAD-60 CARRYING CASES

Designed exclusively for use with the Rados brand 5X & 6X Series electronic dosimeters helps to realize substantial savings on clip replacement and dosimeter repairs. Experience less down time for you in-house inventory all with a unique design the allows for secure use on a lanyard, belt or other device. Carrying cases are also equipped with belt clip or belt loop.

RAD-60 CARRYING CASES

Product Code Description

SEIrad60cc RAD-60 Carrying Cases

Page 22: InMed Radiation Detection Brochure 2013-14

22 I www.inmed.com.au

SPECTROSCOPIC PERSONAL RADIATION DETECTORS

POLIMASTER PM1401K HAND HELD RADIONUCLIDE IDENTIFICATION DEVICE

The PM1401K is a unique light-weight multipurpose hand held radionuclide identifier designed for easy detection and location of the alpha, beta, gamma and neutron radiation sources, precise measurement of the alpha and beta surface contamination levels and gamma dose rate, and reliable identification of the radioisotopes.

For example, the PM1401K is able to distinguish between naturally occurring radiation materials (NORM), medical isotopes, industrial sources of radiation, which are potentially dangerous to the general population, and of the sources of radiation that are inherently dangerous, such as weapons-grade nuclear materials.

PM1401K HAND HELD RADIONUCLIDE IDENTIFICATION DEVICEProduct Code Description

POLPM1401Kindent PM1401K Identifier Hand Held Radionuclide Identification Device

POLIMASTER RADIOISOTOPE IDENTIFIER PM1410

The PM1410 Radioisotope Identifier is a universal and multifunctional portable device of the expert level.

According to its functional abilities, technical parameters and design the instrument fully belongs to the class of Radionuclide Identification Devices and primarily designed to confirm the detection of radiation sources when they are found by stationary radiation portal monitors installed at checkpoints of various radiation-dangerous objects and controlled areas.

The device can also be used for secondary – expert – identification of radionuclide composition in case of impossibility to clearly interpret the results obtained using other types of equipment, like Spectroscopic Personal Radiation Detectors.

RADIOISOTOPE IDENTIFIER PM1410

Product Code Description

POLPM1410 PM1410 Radioisotope Identifier

POLIMASTER PM1710C GAMMA AND PM1710GNC GAMMA-NEUTRON MONITORS

The wall-mounted PM1710C Gamma and PM1710GNC Gamma-Neutron monitors are highly sensitive instruments designed for radiation monitoring and thus protection of a building against radioactive contamination.

The detectors may be fixed near doorways and facility entrances to continuously monitor human traffic and their luggage against radioactive sources presence.

PM1710C GAMMA AND PM1710GNC GAMMA-NEUTRON MONITORSProduct Code Description

POLPM1710C PM1710C Gamma Monitors

POLPM1710GNC PM1710GNC Gamma-Neutron Monitors

Page 23: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 23

POLIMASTER SPECTROSCOPIC PERSONAL RADIATION DETECTORS PM1703MB / GNB

The family of Polimaster’s Gamma and Gamma-Neutron Spectroscopic Personal Radiation Detectors (SPRDs) which utilize advanced search algorithms and can be used for detection and primary radionuclide identification of the radioactive sources even by the non-trained personnel.

• Alert the user of the presence of a radiation source through audible, visual and vibrating alarms

• Record and analyse gamma spectra as well as identify radionuclide composition

The PM1703MB/GNB SPRD models have the following functions:

• Detect only gamma or both gamma and neutron radiation sources (PM1703MB and PM1703GNB respectively)

• Search for and locate the gamma or neutron radiation sources including nuclear weapon materials

SPECTROSCOPIC PERSONAL RADIATION DETECTORS PM1703MB / GNBProduct Code Description

POLPM1703MB PM1703MB Spectroscopic Personal Radiation Detector

POLPM170GNB PM1703GNB Spectroscopic Personal Radiation Detector

POLIMASTER PM1703MO-1A / B PERSONAL COMBINED RADIATION DETECTORS/DOSIMETERS

The PM1703MO-1A and PM1703MO-1B instruments combine features of both SPRD and dosimeter in the one housing.

The small-sized GM tube allows for measuring dose and dose rate of the gamma radiation in the wide energy range while highly sensitive CsI(Tl) scintillation detector allows for searching of the radioactive and nuclear materials and primary radionuclide identification of the radioactive sources.

PM1703MO-1A / B PERSONAL COMBINED RADIATION DETECTORS/DOSIMETERSProduct Code Description

POLPM1703MO-1A PM1703MO-1A Personal Combined Radiation Detector/Dosimeter

POLPM1703MO-1B PM1703MO-1B Personal Combined Radiation Detector/Dosimeter

POLIMASTER SPECTROSCOPIC PERSONAL RADIATION DETECTORS PM1704/M/GN

The PM1704M/GN is a new class of small (pocket-size) pager-style gamma and gamma-neutron spectroscopic personal radiation detectors.

The family of multipurpose, highly sensitive and compact gamma and gamma-neutron spectroscopic personal radiation detectors which has advanced search algorithms that enable the measurement of radiation intensity and the quick radionuclide identification of radioactive sources. Devices are equipped with a colour LCD display and a user-friendly interface, and are highly ergonomic and convenient to use even in harsh environments.

SPECTROSCOPIC PERSONAL RADIATION DETECTORS PM1704/M/GNProduct Code Description

Please contact us for more information when ordering these products.

PM1704 Spectroscopic Personal Radiation DetectorPM1704M Spectroscopic Personal Radiation DetectorPM1704GN Spectroscopic Personal Radiation Detector

SPECTROSCOPIC PERSONAL RADIATION DETECTORS

Page 24: InMed Radiation Detection Brochure 2013-14

24 I www.inmed.com.au

SPECTROSCOPIC PERSONAL RADIATION DETECTORS

ATOMTEX AT6101 AND AT6101B SPECTROMETERS

AT6101 and AT6101B Portable multifunction scintillation gamma spectrometers can be used in laboratories as well as for working in field conditions.

Main spectrometer function is radionuclide identification (natural, medical, industrial, nuclear) without connection to a PC.

Additional functionality: search and detection of radioactivity sources and dose rate measurement.

AT6101 AND AT6101B SPECTROMETERS

Please contact us for more information when ordering this product.

ATOMTEX AT6102 AND AT6102A SPECTROMETERS

AT6102 and AT6102A Spectrometers are multifunctional portable single-block radiation monitoring devices primarily used for radionuclide detection and identification (natural, medical, industrial, nuclear) without connection to PC.

AT6102 Spectrometer, unlike AT6102A model, has additional neutron detection option.

AT6102 AND AT6102A SPECTROMETERS

Product Code Description

ATO32 AT6102 Spectrometer

ATO33 AT6102A Spectrometer

SE INTERNATIONAL URSA II: UNIVERSAL RADIATION SPECTRUM ANALYSER

The URSA II, with a full-featured MCA program, can be used with practically any radiation detector and can extract any data your detector can supply!

It has been designed taking into account comments and requests from our current URSA customers.

URSA-II MCA, the all-new fully, quantitative Windows™ based URSA-II software package has been designed for ease of use in a 32-bit Windows™ environment.

UNIVERSAL RADIATION SPECTRUM ANALYSER

Product Code Description

SEIURSAII URSA II Universal Radiation Spectrum Analyser

Page 25: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 25

SE INTERNATIONAL RADIATION ALERT® GAMMAPAL - PORTABLE ANALYSIS LAB

The GammaPAL is the ideal instrument for detecting contamination in food, soil, and water.

The GammaPAL is a portable laboratory containing all the items you need for sampling in the field or from a stationary base of operations. It is a complete measuring system for analysing radiation contamination in food, as well as in air swipes, soil samples, and other materials.

RADIATION ALERT® GAMMAPAL

Please contact us for more information when ordering this product.Includes: Inspector survey meter with wipe test plate and swipes for preliminary testing, a rugged Nomad Pocket PC with bar code scanner for eas-ily labelling samples, tools for sample collection, and screw top marinelli beakers for sample stor-age. The GammaPAL is your all-in-one sampling kit for radiation safety.

ATOMTEX AT1321 SPECTROMETER (SPECTROMETRIC PERSONAL RADIATION DETECTOR)

Spectrometric Personal Radiation Detector (SPRD) is a compact belt instrument for rapid detection of radiation materials and sources with radionuclide identification function: natural, medical, industrial, nuclear radionuclides (special order).

The radiation detector operation principle is based on constant count rate measurement of gamma radiation impulses by a scintillation detector, data analysis in order to detect gamma-radiation pollution, amplitude spectrum measurement with subsequent automatic processing to receive dose rate value and radionuclide composition data of the relevant gamma-radiation source.

These data are stored in the non-volatile memory of the detector.

Geiger-Muller counter tube with a filter is used to extend the dose rate measuring range. The filter facilitates smoothing of sensibility energy dependence.

SPRD has internal GPS-module for measurement data geo-referencing and mapping.

AT1321 SPECTROMETER (SPECTROMETRIC PER-SONAL RADIATION DETECTOR)Please contact us for more information when ordering this product.

SPECTROSCOPIC PERSONAL RADIATION DETECTORS

Page 26: InMed Radiation Detection Brochure 2013-14

26 I www.inmed.com.au

PAGE COMPLETED

SE INTERNATIONAL RAP47 AND RAP640 SCINTILLATION PROBES

The CsI (Tl) crystal used in Radiation Alert® Probes has a higher atomic number, is more rugged, and less hygroscopic than a typical Nal detector.

The improved gamma ray absorption allows a thinner crystal to be used, effectively reducing the background count rate.

SCINTILLATION PROBES

Product Code Description

SEIRAP47 RAP47 Scintillation Probe

SEIRAP640 RAP640 Scintillation Probe

SE INTERNATIONAL CDV-700 RP REPLACEMENT PROBE

The CDV-700RP probe is specifically designed to easily replace the existing beta/gamma probe adding an alpha window to the CDV-700 survey meter and deliver greater sensitivity.

The grip on the probe is adjustable to allow for the perfect fit to Victoreen or Lionel meters. Just unplug the existing probe and plug in the CDV-700RP. (For use with CDV-700 meters only).

CDV-700 RP REPLACEMENT PROBE

Please contact us for more information when ordering this product.

SE INTERNATIONAL RAP-RS1 REPLACEMENT PROBES

RAP-RS1 Probe - External Halogen-quenched, uncompensated GM tube with thin mica window, 1.4-2.0mg/cm2 area density.

• Effective diameter of window is 45mm

• Anodized aluminium housing

• Connector - Amphenol-Tucal

• Handle - Black foam grip

RAP-RS1 REPLACEMENT PROBES

Product Code Description

SEIRAPRS1 Rap-RS1 Replacement Probe

SE INTERNATIONAL 1 X 1 AND LARGER SCINTILLATION PROBES

We have a number of sizes available to fit the resolution specific to your application.

1 X 1 AND LARGER SCINTILLATION PROBESPlease contact us for more information when ordering this product.

SCINTILLATION & GM PROBES

Page 27: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 27

RADIATION SPECTROMETERS

ATOMTEX AT1315 GAMMA BETA RADIATION SPECTROMETER

The AT1315 is a two-channel scintillation gamma and beta spectrometer designed for simultaneous and selective detection of the following:

• 137Cs, 134Сs, 131I and 90Sr radionuclide specific activity in natural samples

• Specific effective activity of 40К, 226Ra, 232Th in construction materials

Can be used for rapid radioactive purity determination of standardized sample heat of metal.

Gamma and beta spectrometer operation principle is based on measurement and transformation of gamma and beta radiation, detected by standalone detection units, into amplitude distributions, which are further transformed into digital code and saved in the detection unit memory.

• 1024-channel analogue-to-digital converter is integrated into smart probes

• Continuous automatic LED stabilisation of spectrometric path in measurement mode

• Calibration integrity monitoring by means of integrated radioisotope check sample with less than the minimum significant activity.

• Computer spectra processing with maximum likelihood method

• Automatic recording of sample density

• Spectra metering with on-line visualisation

• Simultaneous spectra metering and processing

• Methodological support of measurements

AT6101 AND AT6101B SPECTROMETERS

Please contact us for more information when ordering this product.

Page 28: InMed Radiation Detection Brochure 2013-14

28 I www.inmed.com.au

ACTIVITY MONITORS

ATOMTEX AT1320, AT1320A, AT1320B GAMMA ACTIVITY MONITORS

Highly sensitive selective wide-range spectrometric scintillation gamma activity monitor is intended to measure the following parameters:

• Measuring 137Cs radionuclide volumetric and specific activity in environmental objects

• Measuring specific effective activity of 40К, 226Ra, 232Th in construction materials

• Rapid determination of (standardized sample heat of metal) metal radioactive purity

AT1320 SERIES GAMMA ACTIVITY MONITORS

Please contact us for more information when ordering this product.

ATOMTEX AT1135 PORTABLE RADIOMETRIC LABORATORY

AT1135 Portable Radiometric Laboratory is a hand-carried measurement instrument of spectrometric type.

It is designed to determine relative activity of 134Cs, 137Cs and 40K gamma-emitting radionuclides in food products as well as in-situ measurement of ambient gamma radiation dose rate equivalent.

AT1135 PORTABLE RADIOMETRIC LABORATORYPlease contact us for more information when ordering this product.

ATOMTEX AT1320A GAMMA ACTIVITY MONITOR (WITH EXPANDED NUCLIDE LIBRARY)

Highly sensitive selective wide-range spectrometric scintillation gamma activity monitor is intended for measuring volumetric (specific) radionuclide activity in 131I, 134Cs, 137Cs, 40K samples with 1 litre Marinelli beaker and 0.5 and 0.1 litre flat-type containers.

• Spectrometric smart probe

• Internal continuous automatic LED stabilisation of gamma counter energy scale, calibration integrity monitoring and automatic calibration with integrated KCl sample

• Recording and storing in memory up to 300 measured spectra

• Automatic background substraction

• Sample activity measurement for materials with wide density range

• Can be used both in stationary and mobile radiation monitoring laboratories

• Methodological and metrological support of measurements

AT1320A GAMMA ACTIVITY MONITOR

Please contact us for more information when ordering this product.

Page 29: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 29

ATOMTEX AT1320M GAMMA ACTIVITY MONITOR

Highly sensitive selective wide-range spectrometric scintillation gamma activity monitor is intended for measuring volumetric (specific) radionuclide activity in 131I, 134Cs, 137Cs, 40K, 226Ra, 232Th samples with 1L Marinelli beaker and 0.5L and 1L flat containers.

AT1320M Gamma activity monitor operating principle is based on sample radionuclide gamma radiation detection by scintillation detector, instrument spectrum measuring and further matrix method processing with measuring of monitored radionuclide volume activity.

Radionuclide activity data is displayed on Information processing unit screen in real-time.

Setting up procedure and parameter check is performed with 133Ba check sample.

Measurement procedure includes preliminary analysis of sample radionuclide composition. Activity calculation is carried out based on the results of monitored sample radionuclide identification procedure.

AT1320CM GAMMA ACTIVITY MONITOR

Please contact us for more information when ordering this product.

ATOMTEX AT1320C GAMMA ACTIVITY MONITOR

Highly sensitive selective wide-range spectrometric scintillation gamma activity monitor is intended for measuring volumetric (specific) radionuclide activity in 131I, 134Cs, 137Cs, 40K, 226Ra, 232Th samples with 1L Marinelli beaker and 0.5L and 1L flat containers.

Gamma activity monitor operating principle is based on the detection unit pulse-height distribution analysis. Controlling PC reads the detection unit data on-line, processes it and displays on computer screen.

The installed PC application software is intended for controlling the activity monitor operation modes, viewing the recorded information, calculating gamma-radionuclide activity and measurement error for chosen measurement geometry, and managing electronic history log of measurement results.

Measurement procedure includes preliminary analysis of sample radionuclide composition. Activity calculation is carried out based on the results of monitored sample radionuclide identification procedure.

AT1320C GAMMA ACTIVITY MONITOR

Please contact us for more information when ordering this product.

ACTIVITY MONITORS

Page 30: InMed Radiation Detection Brochure 2013-14

30 I www.inmed.com.au

PORTABLE RADIATION SPECTROMETERS

ATOMTEX AT6101D SPECTROMETER

The AT6101D is a portable multifunction scintillation gamma spectrometer.

It is designed to measure specific effective activity value for 40K, 226Ra, 232Th natural radionuclides in construction materials, raw and manufactured products, manufacturing waste and other objects of environment, as well as measurement of 137Cs surface activity in soils and subsoils, and 137Cs specific activity in agricultural raw materials, forestry products and construction materials.

In situ measurement are made for 2-π and 4-π geometries without preliminary sampling.

AT6101D SPECTROMETER

Product Code Description

ATO29 AT6101D Spectrometer

ATOMTEX AT6101DR SPECTROMETER

The AT6101DR Multifunction portable spectrometer is designed for radionuclide identification. The AT6101DR can identify 40K, 226Ra, 232Th natural radionuclide content measurement, 134Cs and 137Cs man-made radionuclide surface activity in situ measurement in soils and subsoils, as well as specific 137Cs and 134Cs radionuclide activity measurement in water, foodstuffs, agricultural and forestry products without preliminary sampling.

Spectrometer may also be used for measurement of ambient gamma-radiation dose equivalent rate on objects of radiation monitoring.

Internal GPS-receiver provides measurement data geo-referencing function.

AT6101DR SPECTROMETER

Please contact us for more information when ordering this product.

POLIMASTER FOOD CONTAMINATION MONITOR PM1406

Food contamination monitor PM1406 is a small size device for measuring radioactive contamination level in food.

It can be used both for food products and liquids monitoring. Using this device one can control radiation both at home and in small shop, restaurants and cafes.

The device has an additional advantage that makes it possible to carry out permanent or periodical radiation environment monitoring in its location place.

Food contamination monitor PM1406 is a perfect combination of professional devices specifications with simplicity of use and affordable price in comparison with professional radiometers.

FOOD CONTAMINATION MONITOR PM1406

Please contact us for more information when ordering this product.

RADIATION ACTIVITY MONITORS

Page 31: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 31

POLIMASTER PM2010M GAMMA DOSIMETER/CHEMICAL AGENT DETECTOR

PM2010M is a two-in-one instrument featuring chemical agent detector and gamma radiation detectors in one unit.

The device can detect and differentiate between organophosphorous (GA, GD, GB, VX, etc.) and arsenic-containing (Lewisite, and Lewisite like) compounds, as well as continuously monitor radiation background and provide audible and visual alarms when preset thresholds are exceeded.

PM2010M GAMMA DOSIMETER/CHEMICAL AGENT DETECTORPlease contact us for more information when ordering this product.

POLIMASTER PM2012M GAMMA DOSIMETER AND CHEMICAL AGENT DETECTOR

The PM2012 portable instrument, designed for continuous monitoring of radiation environment and ambient gamma radiation dose rate measuring as well as detection of presence of toxic vapors in the air.

• Continuous measurement of ambient Dose Equivalent Rate and Dose Equivalent of gamma radiation up to 10 Sv/h (1000 R/h), and 10 Sv (1000 R) respectively

• Simultaneous, independent detection of organophosphorous compounds

• Audible and visual alarms

• Non volatile memory for data storage

• IR port for data download of instrument’s operation history to a PC

• The instrument can be connected to the on-board power supply or AC main line

• Waterproof and shockproof case

COMBINED GAMMA DOSIMETER AND CHEMICAL AGENT DETECTOR PM2012MPlease contact us for more information when ordering this product.

ATOMTEX AT6101C SPECTROMETER (SPECTROMETRIC PORTABLE RADIATION SCANNER)

AT6101C Spectrometric Portable Radiation Scanner is used for detection of radioactive sources and is an efficient technical means of radiological terrorist threats and other activities prevention, such as illegal storage, use, transfer and traffic of radioactive substances and materials.

The AT6101C can also be used for radiation monitoring of areas, routes, isolated grounds, industrial sites and buildings.

Scanner is stored and carried in a backpack. SPRS is supplied with gamma-radiation spectrometric detecting unit, neutron radiation detecting unit, and can be supplied with wide-range dosimetric detecting unit (optional).

AT6101C SPECTROMETER (SPECTROMETRIC PORTABLE RADIATION SCANNER)Please contact us for more information when ordering this product.

DOMESTIC SECURITY

Page 32: InMed Radiation Detection Brochure 2013-14

32 I www.inmed.com.au

PEDESTRIAN MONITORS

The main task of the pedestrian portal monitors is combating illicit trafficking of radioactive and nuclear materials through state borders or from/to limited access areas.

Polimaster offers pedestrian portal monitors of different configuration and sensitivity to fulfil wide range of customer’s needs.

VEHICLE MONITORS

Gamma, neutron and gamma-neutron family of radiation portal monitors for search for radioactive and nuclear materials in trucks and cars.

The vehicle portal monitors can be equipped with video monitoring system to record the image of a car, that triggered the alarm of the monitor.

RAILWAY MONITORS

Highly sensitive family of radiation portal monitors to monitor a railway line.

The portal monitors detect even slightest traces of the hidden radioactive materials and locate a car with radioactive substances. The radiation portal monitors of PM5000A series designed for use in the harsh environment and can be used in extreme climate conditions.

Automated fixed radiation portal monitors are considered to be the first measure to prevent the illicit trafficking of radioactive and nuclear materials. These monitors are designed for the monitoring of the pedestrians, trucks, cars, trains, etc.

POLIMASTERRADIATION PORTAL MONITORS

RADIATION PORTAL MONITORS

Page 33: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 33

PEDESTRIAN MONITORS

Pedestrian radiation monitor is an automatic fixed means of radiation monitoring for detecting sources of gamma radiation in a stream of people, crossing access control points.

• 2-second triggering when the threshold level is exceeded by 0.05 µSv/h (BDKG-11/1) and 0.03 µSv/h (BDKG-19)

• Rapid accommodation to radiation background change

• Sound and light alerts are emitted when the threshold levels are exceeded

• A monitoring network with several pedestrian radiation monitors can be arranged with the help of dedicated software

• Mobility and passage formation capability

• Radiation monitor components self-test function during operation

• Continuous and casual radiation monitoring

• Mains/integrated battery operation

VEHICLE MONITORS

Automatic fixed means of radiation monitoring based on AT2327 Alarm dosimeter for detecting sources of gamma radiation in vehicles, which cross access control points.

• Up to 10 highly sensitive smart probes in sealed aluminium cases for simultaneous gamma radiation monitoring

• Automatic switching from the background radiation measuring mode to the detection mode when the control zone line is crossed by a moving vehicle

• Set threshold levels are automatically corrected according to changes of natural radiation background

• Sound and light alarm in case threshold levels are exceeded

• The radiation monitor components perform self-tests during operation

RADIATION PORTAL MONITORS

The Atomtex AT2327 is an automatic fixed means of radiation monitoring for detecting sources of gamma radiation in a stream of people, crossing access control points or vehicles, which cross access control points.

ATOMTEXRADIATION ALARM DOSIMETER / RADIATION MONITOR

Page 34: InMed Radiation Detection Brochure 2013-14

34 I www.inmed.com.au

ATOMTEX AT2327 ALARM DOSIMETER

AT2327 Alarm dosimeter can be used for building a flexible and multichannel stationary system for radiation monitoring of radiation-sensitive and radiation-dangerous sites, areas and facilities, as well as for radiation monitoring of ecological environment.

• Gamma and neutron radiation smart probes

• Independent measurement for each channel of wide range gamma and neutron radiation dose rate and neutron flux density

• Sound and light alarm in case threshold levels are exceeded for each detection unit

• Fault diagnostics

• History logging of dose rate levels and cases of threshold crossing

• Software for displaying current radiation environment in monitored area on PC screen

• Backup power supply unit

• Mobile one-channel version for vehicle mounting with any DU from the delivery set

AT2327 ALARM DOSIMETER

Please contact us for more information when ordering this product.

ATOMTEX AT5350/1 STANDARD DOSIMETER

AT5350/1 Dosimeter is a high accuracy class instrument with high functional capabilities.

The dosimeter is composed of electrometer measurement unit (electrometer) and a set of ionization chambers of different volume, manufactured by PTW-Freiburg: 0.02; 0.125; 0.6; 30 and 1000сm3.

AT5350/1 STANDARD DOSIMETER

Please contact us for more information when ordering this product.

ATOMTEX AT2327 ALARM DOSIMETER WITH DATA DISPLAY

The AT2327 Alarm Dosimeter with Data Display is intended for radiation monitoring of radiation-sensitive and radiation-dangerous areas and facilities.

• Gamma smart probe is used for measuring of radiation background level.

• Dosimeter operation algorithm provides measurement continuity, rapid reaction to background radiation level change and real time display of detection unit data on external display.

• Ambient temperature and current time and date is additionally displayed.

• Control unit is to be installed indoors.

Control unit is responsible for controlling the operation modes, performing necessary calculations, storing and backing-up measurement results, as well as for supplying power to devices. It hosts command console, interface adapter and backup power supply.

AT2327 ALARM DOSIMETER WITH DATA DISPLAYPlease contact us for more information when ordering this product.

STANDARD DOSIMETERS

AREA MONITORS

Page 35: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 35

ATOMTEX AT1316 WHOLE BODY COUNTER

AT1316 Whole body counter (WBC) is intended for express-monitoring and measuring of gamma-emitting radionuclides in human body, as well as for internal exposure dose estimation (“Sitting straight” geometry).

• Stabilized spectrometric path

• Spectrometric/radiometric measurement modes

• Efficient algorithm of spectra radiometric processing using maximum likelihood method for 137Cs and 134Cs radionuclide activity measuring

• Monitored radionuclide composition in radiometric measurement mode (60Co, 106Ru, etc.) can be expanded

• Calculation of expected annual effective internal exposure dose for incorporated 137Cs radionuclide

AT1316 WHOLE BODY COUNTER

Product Code Description

ATO23 AT1316 Whole Body Counter

ATO24 AT1316a Whole Body Counter

ATOMTEX AT1322 AND AT1322/1 WHOLE BOUDY COUNTERS

AT1322 and AT1322/1 scintillation Whole-body counters (WBC) are fixed instruments for measurement of 131I and 133I radionuclides content in human thyroid gland.

• High examination rate: 3 minutes per person

• Automatic LED stabilisation of WBC energy scale

• Flexible software control of WBC functions, generation of database and report based on measurement results

• Compact design

• USB Counter-to-PC connection

• Can be operated independently or together with AT1316A, as well as part of mobile spectrometric laboratory

AT1322 AND AT1322/1 WHOLE BOUDY COUNTERS

Product Code Description

ATO25 AT1322 and AT1322/1 Whole Boudy Counters

WHOLE BODY COUNTERS

Page 36: InMed Radiation Detection Brochure 2013-14

36 I www.inmed.com.au

GAMMA BEAM IRRADIATORS AND CALIBRATION BENCHES

ATOMTEX AT-03 CALIBRATION STAND

AT-03 Automated calibration stand is designed for positioning of standard and calibrated dose rate and dose measuring instruments in X-ray field.

Calibration stand provides positioning of standard and calibrated equipment on the desktop and moving them to a specified working distance from the X-ray irradiators using a positioning system.

Stand coordinates are linked to the center of the irradiator and of the X-ray beam axis based on the alignment results using the measuring rods and laser systems.

Stand management functions are carried out by the software and a portable control panel.

The video surveillance system is used for remote reading of indications on the scales of calibrated devices.

AT-03 CALIBRATION STAND

Please contact us for more information when ordering this product.

ATOMTEX UDG-AT110 GAMMA BEAM IRRADIATOR WITH CALIBRATION BENCH

AT110 Gamma beam irradiator with calibration bench is designed for verification, calibration and examination of ionization radiation measurement instruments in collimated field of gamma radiation.

Irradiator based on the use of radionuclide sources of 137Cs.

The installation scheme is realized with a fixed irradiator and linear-positioned platform of calibration bench.

The range values of dose rate of gamma radiation is achieved by using different sources of 137Cs with different activity and changing in the distance “a source-detector”.

UDG-AT110 GAMMA BEAM IRRADIATOR WITH CALIBRATION BENCHPlease contact us for more information when ordering this product.

Page 37: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 37

ATOMTEX UDG-AT130 GAMMA BEAM IRRADIATOR WITH CALIBRATION BENCH

Gamma beam irradiator with calibration bench AT130 are designed for verification, calibration and examination of ionization radiation measurement instruments in collimated field of gamma radiation.

Irradiator based on the useof radionuclide sources of 137Cs, additionally 60Co and 241Am.

The installation scheme is realized with a fixed irradiator and linear-positioned platform of calibration bench.

The range values of dose rate of gamma radiation is achieved by using different sources of 137Cs with different activity and changing in the distance “a source-detector”.

UDG-AT130 GAMMA BEAM IRRADIATOR WITH CALIBRATION BENCHPlease contact us for more information when ordering this product.

GAMMA BEAM IRRADIATORS AND CALIBRATION BENCHES

Page 38: InMed Radiation Detection Brochure 2013-14

38 I www.inmed.com.au

TERMS AND CONDITIONS

These Terms and Conditions of Sale supersede all prior terms and conditions that may have been issued by InMed Pty Ltd hereinafter referred to as InMed.

1. General All tenders and quotations are submitted by InMed and all orders are accepted by InMed solely on and subject to the following Terms and Conditions of Sale. These Terms and Conditions of Sale shall be deemed to be incorporated in any Contract or Agreement of Sale between InMed and the Customer to the exclusion of all other terms and conditions except in such circumstances as are specifically accepted by InMed in writing.

2. Limits of Contracts Tenders and quotations submitted and orders accepted only include such goods or accessories (“the Goods”) and additional services (“the Services”) as are specified therein. Any variation must be made in writing between InMed and the Customer.

3. Literature and Suitability of Goods and Services Advertising and other literature provided by InMed contains general information only and this information will not form part of any contract or agreement between InMed and the Customer.

The Customer is solely responsible for determining the suitability of the Goods for the purpose for which they are intended for use by the Customer and expressly acknowledges that InMed is not aware of that purpose and that the Customer has not relied on InMed’s advice.

4. Price Unless otherwise confirmed in writing by InMed, all prices quoted and acknowledged are in Australian dollars (“$A”) and are net ex works Sydney.

Prices confirmed by InMed’s order confirmation will remain fixed, whenever possible, up to the delivery date agreed and specified on the order confirmation.

Prices are based on the exchange rate of the day and will be subject to any upward exchange rate variations greater than 5%.

5. Taxes and Government Charges All prices quoted and acknowledged by InMed exclude any local or international taxes or government charges that may be applicable except if specifically stated on the quotation. InMed may add these taxes or charges to prices including without limitation any goods or services tax or other similar tax.

6. Order Transmission For all goods over $1,000.00 Ex GST, InMed will only accept written orders or confirmatory notification emailed to any InMed email address including but not limited to [email protected].

Order transmission can include signing of InMed’s quotation form. Orders under $1,000 Ex GST can be accepted in writing or via verbal order. Verbal orders will still be subject to these same terms and conditions. Order transmission can include signing of InMed’s quotation form.

7. Order Confirmation For all written orders, InMed will confirm, in writing, details of the Goods and Services to be supplied, price, payment terms, expected delivery times and any further specific conditions if any.

8. Cancellation of Orders To the extent permitted by law, an order or part of an order may not be cancelled and Goods may not be returned to InMed for credit, unless previously agreed to in writing by InMed. Any order cancellations will be subject to a minimum restocking fee of 20% of the order value, or forfeiture of any deposit monies paid, whichever is greater. In addition, when cancellation is agreed to InMed reserves the right to claim for indemnities for loss and damage. InMed will not accept cancellation or return of any specially ordered products or any manufactured products manufactured.

9. Payment Terms In no event shall defects or short supply be grounds for the suspension or delay of any payment due to InMed as detailed in the order confirmation.

Payments terms are 14 days for all equipment unless stated in the quotation. Payments falling 30 overdue will incur a 15% per annum surcharge, additionally should

legal action or further debt collection be required, then the customer agrees that such costs will be added to the invoice total.

Additionally all invoices which fall overdue will automatically be subject to an upward exchange rate variations for the imported component of their order.

10. Delivery The delivery times communicated to the Customer are estimates only and InMed shall not be liable for any loss, damage or delay suffered by the Customer or its customers arising from or connected to late or non-supply of the Goods or Services.

11. Freight Costs Unless otherwise agreed in writing, all costs related to packing, shipment and delivery of any Goods will be to the Customer’s account and not included in the quoted price.

12. Passing of Risk Risk in Goods supplied under these Terms and Conditions of Sale passes to the customer immediately upon delivery to the Customer.

13. Loss or Damage in Transit In the event that the Goods are lost or damaged in transit the Customer must notify InMed in writing immediately the loss or damage is discovered. The Customer shall render to InMed such assistance as may be necessary to press claims on carriers.

14. Inspection The Customer shall inspect the Goods immediately upon delivery and shall give notice in writing within 7 days of delivery to InMed of any deliveries which are not in accordance with these terms.

15. Retention of Title(a) Title in the Goods delivered under a particular order shall not pass to the Customer until receipt and acceptance of payment by InMed for the Goods and until all other amounts owing to InMed in respect of the Goods are paid in full. InMed reserves the right to enter Customer’s premises (or the premises of any associated company or agent where the Goods are located) without liability for trespass or any resulting damage and retake possession of the Goods for the purposes of keeping or reselling those Goods until all accounts in respect of those Goods have been fully paid.

(b) The Customer shall not sell or agree to sell Goods delivered until payment in full has been made to InMed. In the event that the Customer does sell those Goods, the proceeds of the sale are hereby acknowledged by the Customer to be assets of InMed and the Customer will hold the proceeds of the sale in a separate bank account upon trust for the benefit of InMed.

(c) Notwithstanding any other arrangement between InMed and the Customer, InMed may sue the Customer for the value of the Goods supplied as a liquidated debt at any time after delivery of the Goods and the expiry of the 30 day credit period.

16. Installation, Training and Other Services Unless otherwise agreed in writing and included in the order confirmation, installation is to be accomplished by the Customer. If required, InMed will provide installation, training and/or other services on a chargeable basis. If these services are required they should be identified at the time of order placement and InMed will include related charges in the order confirmation.

17. Express Warranty(a) The “Express Warranty” means the warranty given by InMed under the terms of this clause 16.

(b) Subject to the receipt of the payment in full, for a period of 12 months from the date of delivery of any NEW Goods, InMed warrants that the Goods are free from defects in workmanship and materials. InMed’s sole obligation under this clause is to, in its sole discretion, repair or replace the Goods or any component of the Goods that InMed determines was defective at the time of delivery.

(c) InMed accepts no liability for damage to or defects in the Goods arising from the improper use, improper handling, and lack of maintenance or by any unauthorised modifications, by the Customer.

(d) The Customer must give notice in writing to InMed of any defects in workmanship and materials as soon

as it becomes aware of the defect and InMed will, at its sole discretion, immediately confirm whether remedial action will be taken.

(e) The Express Warranty will only cover the free of charge replacement or repair and ex works delivery of defective part(s) unless specifically stated in the quotation.

(f) The Express Warranty does not imply any liability on InMed for any damage, injury or loss of any kind whatsoever to any property or persons caused from or in connection with the installation or use of the product(s) supplied.

(g) Second hand goods do not come with any warranty unless specifically stated in the quotation.

17. Service and Repair Unless otherwise agreed in writing, repair facilities or parts in respect of the Goods will be available only in accordance with the terms of the Express Warranty.

18. Return of Goods The return of Goods for either Express Warranty claims, repair, general service or for any other reason (“the Return of Goods”) will be at the Customers Risk. InMed is not liable for damage or loss in transit of Goods being returned. The Customer must pack Return Goods adequately and cover all necessary insurance.

19. Limitation of Liability(a) To the extent permitted by law, the Express Warranty is in substitution for all other terms, conditions, warranties and representations, express or implied, by statute or otherwise, as to the description, merchantable policy or fitness for purpose of the Goods or Services which terms, conditions, warranties and representations are hereby excluded.

(b) Certain legislation, including the Trade Practices Act 1974, as amended or replaced, may imply warranties or conditions or impose obligations upon InMed which cannot be excluded, restricted or modified except to a limited extent. These Terms and Conditions of Sale must be read subject to any such statutory provisions. If such statutory provisions apply, to the extent to which InMed is entitled to do so, its liability will be limited at its option to:

(i) Replacing the Goods;

(ii) Supply of equivalent Goods;

(iii) Payment to the Customer of the cost of replacing the Goods;

(iv) Payment to the Customer the cost of having the Goods repaired;

(v) the repair of the Goods;

(vi) resupply of the Services; or

(vii) payment to the Customer of the cost of having the Services resupplied.

(c) To the extent permitted by law, and subject only to any express exceptions contained in these Terms and Conditions of Sale, InMed will under no circumstances be liable to the Customer for any loss, damage, expense, injury or death sustained or incurred by the Customer or any other party resulting from directly or indirectly, the supply, performance, handling, installation or use of any Goods or the supply of any Services or out of any breach by InMed under any contract incorporating these Terms and Conditions of Sale or out of the negligence of InMed.

20. Breach of Conditions of Sale If at any time the Customer breaches the Terms and Conditions of Sale, InMed is entitled to cancel all previously accepted orders from the Customer without liability and without prejudice to any remedies or right to damages resulting from the Customer’s failure to perform the contract.

21. Governing Law and Submission to Jurisdiction The Terms and Conditions of Sale are governed by the laws of the State of New South Wales and the parties irrevocably agree to submit to the non-exclusive jurisdiction of the courts of New South Wales.

Page 39: InMed Radiation Detection Brochure 2013-14

www.inmed.com.au I 39

TERMS AND CONDITIONS

These terms are in addition to the terms and conditions of sale.

Exclusions• Any penetrations, cutting, patching and making good

for sub-trades

• Making good to existing surfaces other than noted in this quotation

• Any Alterations to existing building services, ie: air conditioning, electrical, fire protection

• Any work outside normal working hours

• Any allowance for caretaker attendance fees

• Any special site allowance, redundancy payments, workers compensation top up insurance, appertaining to this project

• Any removal of products containing asbestos or for costs associated with such removal

Commencement Our company policy is that we comply with various councils and local authorities and therefore require notification of plan submission and approval by the council.

Access The above quotation is subject to clear and unrestricted access for the hoisting of men and materials.

Rise and Fall This quotation is firm if accepted within 30 days, and is subject to review if accepted after this period.

Cost variations due to raw material prices will affect final pricing on construction jobs, a progress payment will be required to secure pricing of fluctuating commodities.

Alterations InMed reserves the right to refuse any alterations to the project after the quotation is accepted. Any alterations requested by the customer are at the customer’s cost. A change in the scope of works does not constitute a new project, only an alteration to the existing one, as such a standard 20% cancellation fee will be charged for projects that do not proceed after ordering.

Payments Progress claims will be due within 14 days from submission of claim.

Retentions This quotation is subject to NIL Retentions being withheld. Installation is not included in the quotation unless specifically stated. No responsibility can be accepted. Delivery covers delivery only and not unpacking.

Service This document sets out the Terms and Conditions which shall apply to the provision of all repair and refurbishment services undertaken by InMed Pty Ltd, (in this document referred to as “us”, “we” or “our”, as appropriate) to customers (in this document referred to as “you” or “your”).

1. General A contract with the Terms and Conditions set out below comes into being when an order is placed with us and when we accept that order (whether by starting work or otherwise). These Terms and Conditions shall override any Terms and Conditions which you may propose, unless agreed in writing by our duly authorised signatory before items are received for performance of the services requested.

2. Pricing(a) Pricing shall be quoted in writing or as otherwise agreed between us and you before work commences. If the price of the work may exceed that shown quotation then we will contact you for authority to proceed at the higher price level and your or your company’s employee’s verbal acceptance shall be sufficient to form a contract at the higher price.

(b) Fixed price repairs are not always possible due to secondary problems that can surface after rectification of original faults.

(c) The cost of packaging, delivery, insurance and GST is not included in the repair price and will be added to quoted prices. We will endeavour to aggregate items together for return, thereby minimising carriage charges.

(d) Items which have not been repaired or which have been repaired under warranty (see clause 4 below) will be returned to you free of all parts and labour charges.

(e) If it is decided that a repair will not be proceeded with either by InMed or by the customer then all expenses incurred to date will be payable by the customer including but limited to all freight, travel and labour.

3. Ownership Of Replacement Parts(a) All parts used in the repair process remain the property of InMed until all invoices relating to the repair are paid in full.

(b) We retain the right to enter premises and reclaim any parts with funds outstanding on them. The cost of such reclamation will be payable by the customer in addition to any outstanding amount for out of pocket expenses and labour charges associated with the original repair work undertaken.

(c) A credit for any reclaimed parts will be issued to the customer less 50% of the parts, if an amount greater than this has already been paid by the customer, the 50% plus any of the aforementioned costs will be deducted and the remainder refunded.

4. Payment Terms(a) Non-credit account customers are required to pay in advance via company cheque, bankers draft, credit transfer or telegraphic transfer.

(b) Credit account customers may pay by any of the above methods, including cheques to the full invoiced amount. Credit payment terms are strictly 14 days net without any set-off from date of invoice unless we agree otherwise in writing. A late payment charge of 5% per calendar month will be payable on all late payments.

(c) You shall notify us of any invoice or delivery note discrepancy within 7 days of receipt to enable corrective action to be taken as soon as practicable.

(d) If payment is not made within the period provided in paragraph 4(b) then we may refuse future repairs until such time as the account has been settled. If the account has not been settled within 90 days then we reserve the right without further reference to you to sell any items retained under this paragraph in full or part (as the case may be) payment of all sums owing to us and if any balance remains following any such sale then we will pay this to you, exercise our right to reclaim parts as per clause 3(b) or alternatively legal action may be commenced to recover all outstanding monies.

5. Warranty(a) If any item which has been repaired or refurbished by us fails within 90 days (or such other period as we may specify in writing prior to undertaking the required work) due to faulty workmanship by us or faulty materials provided by us (but not for any other reason) then we will rectify any such defect at our expense. At our discretion, we may in the alternative refund to you the sums paid by you to us for the original defective repair work.

(b) A charge will be made at our standard rates (details available on request) for labour and additional parts subsequently found to be faulty in addition to the parts which we originally repaired during warranty investigations.

(c) If the item has been tampered with, subjected to misuse, returned for no apparent reason or returned for any reason outside the terms of the original order then the warranty described above shall be void and we shall be entitled to charge our standard repair prices.

(d) Any claim under the warranty for damage in transit must be made verbally within 24 hours of receipt of the item by you, followed by a written communication within 48 hours, otherwise any such claims shall be invalid.

6. Repair Process (a) Items submitted for tests and repairs shall be processed in accordance with our defined repair procedures.

(b) Repaired units shall be submitted to a documented final acceptance test in accordance with our standard

procedures. Where possible this shall include testing in accordance with the manufacturers original specifications. Details of final acceptance tests are available on request.

(c) Wherever possible we will replace components on a like for like basis. Where an exact replacement is not practical, because of the cost or lead times, InMed Pty Ltd reserves the right to use a commercially available alternative.

7. Repair Cycle Time(a) Unless we agree otherwise with you in writing before your order is placed, we shall use all reasonable endeavours to comply with the repair cycle time which is ten (10) working days (time not being of the essence), subject to spares being available. Repair cycle time is the period from the first working day on which the item is reported faulty until the effected repair date.

(b) Items received without an order shall be “quarantined” until details of the order are received from you.

Similarly, if you have an outstanding account with us then we may deal with the items in accordance with paragraph 4(d).

(c) If an item has to be held awaiting parts or if paragraph 6(b) applies, you will be notified as soon as reasonably practicable.

(d) If the item you wish to have repaired or refurbished is not covered in our current repair portfolio we will contact you to agree the repair cycle time and price which will apply to that item.

8. Return of Non-conforming Items Where it is not possible to return an item in the condition which conforms with your order, your instructions will be requested. Where the unrepaired item is to be returned to you this will be done so at your cost. Where the item is not to be returned it will be disposed of by us at no cost to you.

9. Force Majeure We shall have no liability to you for any delays in performance or any non-performance of our obligations as a result of causes beyond our control (which for the avoidance of doubt shall include, but not be limited to, acts of God, strikes, lock-outs, non-availability or the extended lead time of parts, etc).

10. Limit of Liability Our liability to you shall be limited to the repair price quoted for each item and in no circumstances shall we be liable to you for loss of data or for loss of profit. No liability or responsibility whatsoever is accepted by us for any third party claims against you in relation to any items on which we have carried out any work PROVIDED THAT this exclusion does not apply to any claim for death or personal injury caused by our negligence.

11. Miscellaneous These Terms and Conditions constitute a complete statement of all Terms and Conditions which shall apply to services provided by us and replace all previous written or oral terms and conditions. These Terms and Conditions may be amended by us from time to time by sending amended Terms and Conditions to you which shall apply to all orders placed after you are deemed to have received the amended Terms and Conditions (which for these purposes shall be deemed to be two days after the date that they are posted to you). No other amendments or variations shall be valid unless signed by our authorised signatory. Failure by either us or you to exercise any rights under these Terms and Conditions shall not constitute a waiver or forfeiture of such rights.

12. Law The construction validity and performance of these Terms and Conditions and any contract incorporating these Terms and Conditions shall be governed by the Laws of New South Wales, Australia and the Australian Courts shall have exclusive jurisdiction.

Page 40: InMed Radiation Detection Brochure 2013-14

MEDICAL | SCIENTIFIC | SOLUTIONS

45 Prime Drive, Seven Hills NSW 2147 PO Box 630, Winston Hills NSW 2153

T 1300 364 336 | +61 2 8814 5488F 1300 364 391 | +61 2 8814 5477

E [email protected] | [email protected] www.inmed.com.au

Want more information?For all products featured in this brochure, please contact your InMed representative or refer to the manufacturer’s website for up-to-date detailed technical information.

i