66
Air to water heat pumps with the highest efficiency for new build Information for installers Daikin Altherma low temperature heat pump

Information for installers Daikin Altherma low temperature ... · Air to water heat pumps with the highest efficiency for new build Information for installers Daikin Altherma low

  • Upload
    doandan

  • View
    221

  • Download
    1

Embed Size (px)

Citation preview

Air to water heat pumps with the highest efficiency for new build

Information for installers

Daikin Altherma low temperatureheat pump

2

ComfortYour customers demand optimal comfort levels at all times for their space heating and domestic hot water needs. The Daikin Altherma heat pump guarantees this as only Daikin can.

ControlOur specially developed and proven control system with its new user interface makes the Daikin Altherma heat pump intuitive and easy to control. This means easy commissioning for you, while users can be totally in charge of their comfort and costs.

Energy EfficiencyBy using free, renewable energy combined with our highly efficient inverter heat pump technology, the Daikin Altherma gives your customers the ultimate in seasonal energy efficiency.

ReliabilityReliability is a prerequisite for any new heating system – for installers and end users. Daikin technology, designed and manufactured to the highest standards, has proved to be the ultimate in reliability. Based on years of development and experience, and manufactured to exact tolerances, our technology will give years of trouble-free operation.

Why choose Daikin?So can you meet all your objectives. As an industry leader, Daikin supports you with

a combination of broad experience, technical innovation and responsive customer service.

Heat pump efficiency =

SCOP =

heating output / year

electricity input / year

The seasonal efficiency (also called SCOP) of a heat pump is the average efficiency over a whole year. The total heating output per year is defined by the climatic conditions and house specifications (heat load, required water temperatures, etc.), and is independent of the type of heating system.The total electricity input per year is the critical parameter, as this is what the customer pays for. This means the SCOP value can be seen as the real operating efficiency of a heat pump system.

3

Daikin quality

Daikin has a worldwide reputation based on 90 years of experience in

the successful manufacturer of high-quality air conditioning equipment

for residential, commercial and industrial use. It has been a leader in heat pump

technology for 56 years. Daikin’s much envied quality quite simply stems from

the close attention we pay to design, production and testing, as well as aftersales

support. To this end, every component is carefully selected and rigorously tested

to verify its contribution to product quality and reliability.

This ensures that every Daikin installation is a successful one for you.

A++

A

System efficiency*:

Seasonal efficiency, smart use of energy

The EU wants to inform people about the amount of energy that products consume, and will ban inefficient products from the market. Seasonally-efficient units are optimised to be energy efficient for the average conditions users can expect over an entire heating and cooling season.

From September 2015, all heating systems, including those using heat pumps, will receive an energy label to help customers make the most energy-efficient choice.

* EHVH04S18CB3V + ERLQ004CV3

Why choose

Daikin Altherma low temperature heat pump?

4

3 systems in 1: heating, cooling and hot waterDaikin Altherma is a total heating and domestic hot water system with an option for cooling. Based on heat pump technology, it represents a flexible and cost-effective alternative to a fossil fuel boiler. The inherent energy efficiency of Daikin Altherma makes it an ideal solution for your customers looking for reduced energy consumption and low CO

2 emissions.

Depending on the model and conditions, a Daikin Altherma heat pump delivers about 5kWh of usable heat for every kWh of electricity it consumes. This means approximately 80% of the heat is free! Talk about a good investment.

The high efficiency systemBy making use of the heat in the outside air, the system uses much less energy while occupants enjoy a stable and pleasant level of comfort. Also, maintenance requirements are minimal, keeping running costs low. Thanks to advanced compressor technology, the energy savings are even greater.

Why heat pump?The Daikin Altherma heat pump uses a sustainable energy source: extracting heat from the outside air. In a closed loop containing a liquid refrigerant, a thermodynamic cycle is created through evaporation, condensation, compression and expansion. This “pumps” heat from a lower to a higher temperature level. Via a heat exchanger the heat gained is transferred to the home’s warm water distribution system. This can be under-floor heating, low temperature radiators and/or fan coil units. For cooling, the system operates in reverse.

80% ambient air

100%energy

25%electricity

The complete solution

5

Solar collectorWith the integrated solar unit or in option with the wall mounted unit

Hot waterHot water is always available with Daikin’s air-to-water heat pump system, along with outstanding energy savings.

ConvectorHeating and cooling with convector integration.

Under floor heatingInterior spaces are warmed using the hot water generated by the heat pump.

Integrated floor standing indoor unitHeating and domestic hot water in one unit.

Outdoor unit

offered in 4 solutions

Best seasonal efficiencies for highest savings on running costs p 08 › Excellent SCOP ratings up to 4.52 for incentive and certification schemes

› No (or very limited) use of electrical assistance for back-up heating

› Best efficiencies achieved within the most relevant temperature range

Perfect fit for new builds and low-energy houses p 14 › Custom-made product for very low heat loads › Built to withstand the most severe winter conditions › Heating, cooling and domestic hot water in one system

Servicing made easy for long and trouble-free operation p 44

Specifications p 47

An innovative product range, designed to deliver only the best in climate control:

Solutions 1. Floor-standing unit with integrateddomestic hot water tank

2. Integrated solar unit and domestic hot water tank 3. Wall mounted unit 4. Monobloc outdoor unit

Different technologies

Specifications p 22 p 28 p32 p 38

The benefits with the low temperature heat pump

› All components and connections factory-mounted

› Very small installation footprint required › Minimum electrical input with constantly available hot water

› Solar support for domestic hot water with solar system

› Lightweight plastic tank › App control possible

› Compact unit with small installation space, almost no side clearances required

› Can be combined with a separate domestic hot water tank (up to 500 litres) with or without solar support

› Compact monobloc for space heating & cooling with optional domestic hot water

› Fuss-free installation: only water connections required

Different heating applications

› Ideal for new houses, low energy houses or together with an existing boiler (bivalent)

› Bivalent option: combinable with a secondary heat source › Reliable operation even when -25°C outside, thanks to frost protection features such as free hanging coil

Functionalities

› Space heating › Domestic hot water › Cooling › Solar connection for hot water production

Installation › 1 indoor unit › 1 outdoor unit

› 1 outdoor unit

Different heat emitters

› Under floor heating › Low temperature radiators › Fan coil units › Heat pump convector

6

Solutions 1. Floor-standing unit with integrateddomestic hot water tank

2. Integrated solar unit and domestic hot water tank 3. Wall mounted unit 4. Monobloc outdoor unit

Different technologies

Specifications p 22 p 28 p32 p 38

The benefits with the low temperature heat pump

› All components and connections factory-mounted

› Very small installation footprint required › Minimum electrical input with constantly available hot water

› Solar support for domestic hot water with solar system

› Lightweight plastic tank › App control possible

› Compact unit with small installation space, almost no side clearances required

› Can be combined with a separate domestic hot water tank (up to 500 litres) with or without solar support

› Compact monobloc for space heating & cooling with optional domestic hot water

› Fuss-free installation: only water connections required

Different heating applications

› Ideal for new houses, low energy houses or together with an existing boiler (bivalent)

› Bivalent option: combinable with a secondary heat source › Reliable operation even when -25°C outside, thanks to frost protection features such as free hanging coil

Functionalities

› Space heating › Domestic hot water › Cooling › Solar connection for hot water production

Installation › 1 indoor unit › 1 outdoor unit

› 1 outdoor unit

Different heat emitters

› Under floor heating › Low temperature radiators › Fan coil units › Heat pump convector

7

With many years of air-to-water heat pump experience and over 175,000 units installed throughout Europe, we continuously strive to optimise Daikin Altherma’s performance. We do this by maximising energy output and limiting electrical inputs. As an installer, this means you are ready to meet the growing demand for more energy efficient systems.

Best seasonal efficiencies,

providing the highest savings on running costs

8

Integrated floor standing unit

Integrated solar unit

Under floor heating

Combine system with solar energy

Wall mounted unit Cooling

Domestic hot water

9

Best seasonal efficiencies

› Low-capacity 4-8kW range is equipped with swing compressor: integration of main moving parts in one component, assuring no abrasion and no refrigerant leakages, guaranteeing optimal reliability and efficiency.

› High-capacity 11-16kW range is equipped with scroll compressors: quiet, compact and robust, guaranteeing optimal operational reliability (no valves and built-in swing-link coupling) and efficiency (through a low initial flow and a constant compression ratio).

Swing Scroll

Daikin Altherma low temperature provides excellent ratings that comply with European legislation and certification schemes, and/or local incentive programs. Each capacity class has an individually sized compressor, dimensioned for optimal efficiencies per capacity range. This avoids having an over-dimensioned compressor with lower seasonal efficiencies. For example, the compressor of the 4kW class is designed to work at optimal frequencies, delivering the low capacities needed by houses with low heat loads. In addition, the Daikin Altherma optimises efficiency at all outside and water temperatures through:

› a pressure sensor for detailed measurement of condensing pressure level to evaluate the optimal amount of subcool

› an individual dimensioned plate heat exchanger per capacity class, to offer optimal efficiencies per capacity range

a. Low running costs: high heat pump efficiencies at all outdoor and water temperatures

10

Best seasonal efficiencies

Daikin Altherma low temperature maintains its high heating capacities even in the lowest outdoor temperatures. Electrical back-up heater assistance is required never or rarely. These high heating capacities, available across the whole Daikin Altherma low temperature 4kW-16kW range, are achieved thanks to the combination of technologies:

-15 -10 -5 0 5

18

16

14

12

10

8

6

4

2

0

Heating capacity (kW)

Outside temperature (°C)

Less BUH required

Heating capacities of a standard air-to-water heat pump compared to the Daikin Altherma units (ERLQ-C range - 11-16 kW)

› Location: Munich › Design temperature: -15°C › Heat load: 14kW › Heating off temperature: 16°C

› + 40% capacity at -15°C › No need for back up heater from -10°C

onwards (compared to -5°C for standard heat pump)

› Optimised controls to achieve higher frequency of use at low outdoor temperatures

› Liquid injection to avoid too-high discharge temperatures when high water temperatures are required at low outdoor temperatures

› Perfectly-dimensioned plate heat exchangers to maximise the heat exchange surface

When the heat load is lower than the maximum capacity of the heat pump system, the compressor can turn in partial load operation. This reduced compressor frequency results in:

› Higher compressor efficiency in partial load operation

› Delivered capacities exactly matching the actual heating demand of the building

› Obtaining the capacities needed with minimum energy consumption

› Less on/off operation, increasing the operation life cycle of the compressor

1 Heat load > max capacity: full load

Compressor will operate at 100% frequency, with

additional electrical assistance if required

2 Max capacity > heat load > min capacity:

partial load compressor will reduce its frequency

delivering the capacities required by the house, with

high operating efficiencies

3 Min capacity > heat load: partial load with on/off

Compressor will work at its minimum frequency with high

operating efficiencies, but switching on/off to deliver

the capacities required

Heat load line

ERLQ006CAV3 max capacity

ERLQ006CAV3 min capacity

-6 -4 -2 -0 2 4 6 8 10 12 14

8

7

6

5

4

3

2

1

0

Heating capacity (kW)

Outdoor temperature (°C)

Max frequency

Wide optimal operation area at relevant outside temperature (-2°C to 10°C)Min frequency

Optimal operation area

c. Minimum energy consumption: Daikin inverter compressors with high modulating range

b. Guaranteed performance: high heating capacities down to low outside temperature

Daikin Altherma low temperature has a high modulating range, meaning the compressor can modulate down to low frequencies to offer the highest efficiencies over the relevant temperature range. Each inverter compressor has a certain maximum and minimum frequency, and works inside the optimal operation area with the highest operating efficiencies. This is illustrated by the graph bellow.

1

2

3

Heat load ERLQ016C

Standard HP system

11

Best seasonal efficiencies

Typical application:

› Location: Paris › Design temperature: -7°C › Heat load: 7kW › Heating off temperature: 16°C

Operation hours kWh heat output Ta switch off

Heat output (kWh)

-10 -2 0 10 20 30

High efficiency crucial in Ta range -2C° to 10°C

Heat load 7kW

1600

1200

800

400

0

1000

800

600

400

200

0

Outdoor temperature (°C)

Operation hours (h)

› Modulating range doubled vs standard air-to-water heat pumps

› New range delivers around 1kW additional in full-load condition at -7°C (+25%)

-6 -4 -2 0 2 4 6 8 10 12 14

Outdoor temperature (°C)

Optimal operation area too small

8

7

6

5

4

3

2

1

0

Capacity (kW)

-6 -4 -2 0 2 4 6 8 10 12 14

Outdoor temperature (°C)

Wide optimal operation area at relevant Ta (-2°C to 10°C)

8

7

6

5

4

3

2

1

0

Capacity (kW)

Standard heat pump Daikin Altherma

The partial load operation and optimal operation area can be illustrated by a typical application in Paris

Resulting in the best possible effficiencies

Efficient partial-load operation is especially important for the temperature range where the highest heat output is required. Typically, 80% of the total heat output is required in an outdoor temperature range of -2°C to 10°C. Achieving high efficiencies in this temperature range contributes strongly to high seasonal efficiencies.

› Largest part of heat output delivered at optimal efficiencies

› Less on/off operation when heat load becomes lower than the minimum capacity the heat pump can deliver, optimising efficiency and comfort

standard heat pump max capacity

Heat load lineHeat load line

standard heat pump min capacity

ERLQ006CAV3 min capacity

ERLQ006CAV3 max capacity

12

Best seasonal efficiencies

The example shown is for a typical application using under-floor heating:

› A water temperature of 38°C is required at a design temperature of -10°C (1)

› A water temperature of only 25°C is required at a space heating off temperature of 16°C (2)

› For temperatures between -10°C and 16°C, the Daikin Altherma unit calculates the required water temperature, to guarantee maximum efficiency, with continuous heating, at each outdoor temperature.

-10°C 16°C

Ta

1

2

Floating set-point

38°C

25°C

T set-point

(TLWC

)

In addition to limiting the electrical input of the compressor and the electrical back-up heater, Daikin pays special attention to limiting electrical inputs of auxiliary components. This also contributes to the high seasonal efficiencies achieved by the Daikin Altherma range.

› Factory-mounted high efficiency circulating pump already qualifying for future regulations (ErP2015) with an A-energy label (EEI ≤ 0.23)

› No standby losses of inverter drive PCB, lowering electricity consumption during standby mode on 4-8 kW class

Applicable units: 4-8kW Location: Munich (Germany)

Advantage compared to tradional HP system Conditions Operating hours

per year Yearly benefit

High efficiency circulating pump 75W less according to EN14511 5300 hours 398 kWh

No standby losses inverter drive PCB 20W less in standby mode 3400 hours 70 kWh

No bottom plate heater 60W less when Ta below 4°C 2800 hours 170 kWh

Applicable units: 11-16kW Location: Munich (Germany)

Advantage compared to tradional HP system Conditions Operating hours

per year Yearly benefit

High efficiency circulating pump 90W less according to EN14511 5300 hours 477 kWh

No standby losses inverter drive PCB 20W less in standby mode 3400 hours 70 kWh

Low capacity bottom plate heater 60W less + smart logic when Ta below 4°C 2800 hours 160 kWh

The combined effect of the Daikin Altherma weather-dependent set-point control and the Daikin Altherma inverter compressors maximises the efficiency at each outdoor temperature, assuring stable room temperatures.

1 Weather-dependent set-point control: Daikin Altherma maximises efficiency at every outdoor temperature through its weather-dependent set-point control. This control logic will always keep the water temperatures as low as possible, to maximise the heat pump efficiency for each specific outdoor temperature. This results in:

› Higher heat pump efficiency with lower water temperatures

› No unnecessary overheating, thereby deliver-ing the temperatures required

› Continuous heating at lower water tempera-tures, providing stable room temperatures

2 Inverter technology: lowering the compressor frequency with increasing outdoor temperatures, thus increasing the efficiency

d. Smart heating control

e. Optimal use of energy limiting electrical inputs of auxiliary components

› No bottom plate heater needed on 4-8kW class › Low-capacity bottom plate heater on 11-16kW class

(ERLQ-C series), only operating during defrost cycles, results in 90% less electricity consumption when compared with standard thermostatic controlled bottom plate heaters.

› Thanks to all these improvements, COP of up to 5.2* is reached

* ERLQ004CV3 with EHSX04P30A

(Ta DB/WB 7°C/6°C - LWC 35°C (DT=5°C))

13

The Daikin Altherma low temperature is fully optimised to fulfil the efficiency, comfort and application needs of newly built houses. In addition, the extended product range allows you to offer your customers the perfect solution for low-energy houses, even for very low heat loads.

Perfect fit

for new builds, as well as for low-energy houses

14

Domestic hot water tank with solar supportProvides hot water at any time, in line with the highest hygiene standards

Outdoor unit

Best seasonal efficiencies

15

Solar collector(With integrated solar unit or in option with the wall mounted unit)

Hot waterHot water is always available with Daikin’s air to water heat pump system along with outstanding energy savings.

ConvectorCooling and heating with convector integration

Under floor heatingInterior spaces can be warmed using the hot water generated by a heat pump.

Wall mounted unitincluding all hydraulic components canbe combined with a separatedomestic hot water tank.

Perfect fit for new builds, as well as for low-energy houses

Daikin Altherma low temperature is designed to meet the requirements of newly built and low-energy houses characterised by low heat loads. The low capacity unit with its high modulating range offers optimal efficiency in most relevant outdoor temperature ranges by combining compressors and plate heat exchangers that have been specifically designed for smaller heat loads. This is designed to meet the needs of the new-build house market in Europe, which is moving towards smaller heat loads due to:

The new-build house market in Europe is moving towards smaller heat loads, due to :

1. Growing importance of low-energy houses

2. Stronger legislation on energy consumption in new residential constructions (e.g. EPBD regulations)

3. Decreasing size of new-build houses

4. EU Member States planning to reach their 20-20-20 targets

Daikin Altherma low temperature offers a full product line-up with a specifically dimensioned heat pump system (compressor, modulating range, plate heat exchanger, …) to deliver the required capacities for the house, with the best possible efficiencies.

Daikin Altherma low capacity unit is developed and dimensioned to reach optimal efficiencies at the most relevant temperature range, thanks to its high modulating range.

A consistent energy label across Europe

The Ecodesign Directive for heat generators and water heaters requires them to carry energy labels which are common across all EU member states. The principle behind this label is already well-known from refrigerators, washing machines and TV sets. Devices and appliances are currently split into efficiency classes on a scale from A++ to G. Dark green represents the highest level of efficiency, dark red the lowest.

Be on the safe side with Daikin

All Daikin units are tested and meet the criteria of the Ecodesign Directive. Our energy labels reliably show the precise efficiency class, both for individual products up to A++ and for packages up to A+. Perfectly matched in terms of their individual components, our complete systems provide both maximum comfort and peace of mind – for dealers, installers and end users.

Example of packaged label: integrated floor standing unit - space heating and domestic hot water

Example of individual product label: monobloc outdoor unit - space heating

a. Optimised unit for low heat loads

EHVX08S18CB3V /ERLQ006CAV3

A+

A

3 kW5 kW

5 kW42 dB

62 dB

EBLQ05CAV3

55°C

4 kW

4 kW

4 kW

A++

35°C

4 kW

4 kW

5 kW

A++

61 dB

0 dB

16

Perfect fit for new builds, as well as for low-energy houses

Outdoor temperature (°C)

Optimal operation area too small and not in relevant Ta (-3°C to 7°C)

8

7

6

5

4

3

2

1

0

Capacity (kW)

-8 -6 -4 -2 0 2 4 6 8 10 12 14 -8 -6 -4 -2 0 2 4 6 8 10 12 14

Outdoor temperature (°C)

Wide optimal operation area at relevant Ta (-3°C to 7°C)

8

7

6

5

4

3

2

1

0

Low-energy houses have a lower space heating off temperature (12°C) than normal insulated houses (16°C). This means that the most relevant outdoor temperature-range for low-energy houses, shifts towards lower temperatures. A typical low-energy house (see details below) has 80% of its total heat output in the outdoor temperature range of -3°C to 7°C.

Typical application:

› Location: Paris › Design temperature: -7°C › Heat load: 4kW › Heating off temperature: 12°C

High efficiency crucial in Ta range -3C° to 7°C

Heat load 4kW

800

700

600

500

400

300

200

100

0

1000

900

800

700

600

500

400

300

200

100

0

Outdoor temperature (°C)

Heat output (kWh)Operation hours (h)

This is illustrated by the practical example below

Resulting in the best possible effficiencies

Operation hours kWh heat output Ta switch off

-10 -5 0 5 10 15 20 25 30

Standard heat pump Daikin Altherma

Heat load line

ERLQ006CAV3 min capacity

ERLQ006CAV3 max capacity

Heat load line

Capacity (kW)

standard heat pump min capacity

standard heat pump max capacity

17

One system for optimal year-round comfort

Optimal comfort conditions

Keeping the house at the desired temperature the whole year, with both heating and cooling possible

› Only one outdoor unit required to provide heating and cooling

› Same emitters can be used for heating and cooling (Daikin heat pump convector or under-floor system)

1. Under-floor heating 25°C 35°C

2. Heat pump convector

3. Low temperature radiators

35°C 45°C

40°C 55°C

The Daikin heat pump convector is specifically designed to offer optimal efficiencies and comfort for residential applications.

› Small dimensions compared to low-temperature radiators

› Low sound level, optimal for bedroom applica-tions (down to 19 dBA)

› High-capacity cooling with water temperatures down to 6° C

The Daikin Altherma low temperature has an operation range up to 55°C leaving water temperature, allowing for connection to all types of low-temperature heat emitters.

b. Maximum comfort

Connectable heat emitters

Stable room temperatures

The combined effect of the Daikin inverter compressors and weather-dependent set-point control guarantees a continuous heating operation.

With higher outdoor temperature, the water temperature will be lowered and the frequency of the compressor reduced, in order to ensure a continuous heating operation, providing stable room temperature.

18

Perfect fit for new builds, as well as for low-energy houses

Balancing vessel

Under-floor heating

Mixing valve

Low-temperature radiator

45°C

35°C45°C

Thanks to the multiple set-point function, a combination of different types of heat emitters operating at different water temperatures is possible. When there is no heating request from the higher temperature zone, the water temperature will be lowered to the temperature required by the low temperature zone. This ensures keeping the water temperatures as low as possible, while always guaranteeing the highest efficiency.

Tset Thermo status

Space 1 low-temperature radiator 45°C OFF ON ON OFF

Space 2 under-floor heating 35°C OFF ON OFF ON

Heat pump OFF 45°C 45°C 35°C

19

Perfect fit for new builds, as well as for low-energy houses

This adequate frost protection results in one product offering throughout Europe, from the south of Spain to the north of Finland.

c. Guaranteed operation: Daikin Altherma is suitable for all climates, even withstanding severe winter conditions

Outdoor unit 4-8 kWDaikin Altherma low temperature has a guaranteed operation down to an outside temperature of -25°C. This ensures sufficient heat pump operation for even the coldest climates.

The 4-8kW range of Daikin Altherma has a specifically designed casing to avoid the risk of ice formation on the outdoor unit coil.

› The outdoor unit has a free hanging coil, ensuring that no ice accumulates in the lower part of the outdoor unit. This is key to offering appropriate frost protection and has the additional advantage that no electrical bottom plate heater is required

› The discharge grille is also specifically designed to avoid ice accumulation

Daikin is renowned for its know-how related to frost protection on its heat pump

range. The outdoor units are specifically designed to avoid ice build-up problems,

even in the most severe winter conditions.

Free hanging coil

4-8 kW: hermetically sealed swing compressor

High pressure switchThe HP switch in the discharge line protects the unit against too high pressure

Four way valveUsed to switch the HP from heating (ON) to cooling mode (OFF)Reversed cycle for defrost

Outdoor unit fan & fan motorHelps control the differential pressure between high- and low-pressure side.Operates according to ambient temperature and condensation temperature.

20

Perfect fit for new builds, as well as for low-energy houses

Hot gas pipe

› Hot gas pass in bottom plate to keep the temperature of the bottom plate positive. All drain holes are open so drain can get out of the unit

› Limited operation (only shortly before and during defrost cycle hot gas will pass through the hot gas pipe)

Bottom plate

Bottom plate heater: 100W reduced to 35 WStandard operation only during defrost (3 min.) and max. 3 times per hour.

Reduction of electrical consumption

Only a small capacity bottom plate heater is installed (35W), with smart operation logic only operating during defrost cycles. This saves around 90% of electricity consumption compared to a traditional heat pump system with a thermostatically controlled bottom plate heater.

Outdoor unit 11-16 kWThe 11-16kW range of Daikin Altherma has specific frost protection to avoid the risk of ice forming on the outdoor unit coil.

› Hot gas pass: hot gaseous refrigerant coming from the compressor runs through the bottom plate to keep the base free of ice and all the drain holes open

› Sub-cool pass: before the refrigerant pipe is split by the distributor to the hairpins, the refrigerant passes through the bottom of the coil to keep this lower part free of ice

Distributor

5 drain holes

More height differenceSealing

Subcool pass

21

Floor-standing unit with integrated domestic hot water tank

saving installation space and time

1.

22

Best seasonal efficiencies

Daikin Altherma low temperature

floor standing unit with integrated

domestic hot water tank is an all-in-

one heat pump unit that includes

the domestic hot water tank (180l or

260l).

This makes it the easiest and fastest

installation for you when domestic

hot water is required. Compact

and yet 100% comfort guaranteed,

certainly the best solution – for you

and your customer!

23

Integrated floor standing unit

› The stainless steel domestic hot water tank is included in the unit, with all connections between the heat pump module and tank factory-mounted. This permits a fast installation compared to a traditional set-up (wall-mounted with separate domestic hot water tank) – saving you time. You only need to connect the water and refrigerant pipes.

› All hydraulic components are included (circulating pump, expansion vessel, back-up heater, etc.). No need to look for third-party components.

Components are accessible from the front

Expansion vessel

Connections from the top

Plate heat exchanger

PCB board

Domestic hot water tank

water pump

a. Easiest and fastest installation, domestic hot water tank included

› The electric PCB board and hydraulic components are accessible from the front. This makes servicing easy and avoids the risk of damage to electrical components due to water leakage.

› All water and refrigerant connections are at the top of the unit, for easy connection and accessibility. And with no connections at the back of the unit, the installation footprint is even smaller.

24

Integrated floor standing unit

728 mm

600 mm + 10 mm clearance on both sides

VS

Thanks to the all-in-one design, the installation space is minimised both in terms of footprint and height

Compared to the traditional split-up version for a wall-mounted indoor unit and separate domestic hot water tank, the integrated indoor unit greatly reduces the installation space required.

1

2

3

4

950 mm + X

580 mm 370 mmX

Hydrobox

DHW tank

600 mm17

32 m

m

Space reduced by more

than 30%

728 mm

Floor standing unit with integrated domestic hot water tank

b. Space saving: compact indoor unit with sleek design your customers will appreciate

Smaller footprint: with a width of only 600 mm and a depth of 728 mm, the integrated indoor unit has a similar footprint compared to other household appliances. For installation, almost no side clearances are required. And no space is needed behind the unit for piping, as all piping connections are at the top. This results in an installation footprint of only 0.45 m2.

Low installation height: both the 180l and 260l versions come with a height of 1732 cm. The required installation height is less than 2 m.

The compactness of the integrated indoor unit is emphasised by its sleek design and modern look, easily fitting with other household appliances.

Traditional setup

25

Integrated floor standing unit

Limited heat loss

The domestic hot water tank of the integrated indoor unit is equipped with thick polystyrene insulation, resulting in 50% less heat loss compared to a standard insulated tank. This means high savings on running costs, as less energy is required for the next heat-up cycle.

Heat loss from the 180l tank: only 1.4kWh per 24h (temperature difference of 45°C between tank and room temperature).

Maximum efficiency

Daikin Altherma low temperature can heat the domestic hot water tank to high temperatures with heat pump operation only, minimising the need for electrical assistance, and maximising efficiency.

Tank temperature up to 55°C with heat pump only, up to 60°C with the standard back-up heater of the heat pump module.

High hot water volumes

The following volumes can be achieved with only one heat-up cycle.

› Hot water volume of 300l available at 40°C (sufficient for six showers) without electrical assistance (260l tank, tank temperature 50°C, cold water temperature 10°C, one heat-up cycle).

› Hot water volume can be increased to 375l using the standard back-up heater (260l tank, tank temperature up to 60°C).

c. Best solution for domestic hot water heating: high efficiency – high comfort

Smart control

Daikin Altherma uses smart controls to heat the domestic hot water tank, maximising efficiency and comfort for the end-user. The combination of the schedule and reheat functions guarantees minimum electrical input and ensures constant availability of hot water.

› Schedule function: heat the tank to a pre-set temperature at a specified time. Can be repeated four times per day, with the possibility of setting two different tank temperatures (storage comfort and storage economic).

› Reheat function: when the tank temperature goes below a specified minimum reheat temperature, Daikin Altherma switches automatically to domestic hot water heating, heating the tank to a specified maximum reheat temperature.

› Both functions can be used individually or in combination to provide the best efficiency and maximum comfort. The schedule function can heat the tank during the night, with the low electricity tariff, up to a relatively low temperature (e.g. 50°C without electrical assistance). When higher hot water consumption occurs during the day (lowering the tank temperature to the minimum reheat temperature) the heat pump will switch automatically to domestic hot water heating with the reheat function to guarantee the constant availability of hot water. Thanks to the large coil surface of the tank (1.56m2) heating the tank with the schedule or reheat functions occurs very quickly.

26

up to 55°C

with heat pump only

Integrated floor standing unit

d. Quick and easy commissioning

e. Easy serviceability

At the first start-up, a quick configuration wizard will guide you smoothly through the commissioning process. Via a series of short questions, the set-up of basic parameters will automatically be completed. Fine-tuning these parameters remains possible using the menu-based navigation. As a result of the quick configuration wizard, only the parameter settings relevant to the installation are shown in the menus. The irrelevant parameters will be hidden and thus inaccessible.

You can download the parameters to a PC as a back-up or for duplication on similar installations. If preferred, you can prepare the parameter settings beforehand and upload them to the unit during commissioning.

Before the actual test-run of the unit, an actuator test mode allows all the wired components to be activated one by one. This makes it easy to do a quick and easy check of all connections and wiring to ensure correct operation. An automatic screed-drying function can be activated: it proceeds through a gradual heat-up of an under-floor heating system to avoid cracks in the floor during first use. Individual and easy-to-programme schedule timers – for heating, cooling, domestic hot water operation and recirculation, noise-sensitive operation and electrical booster heating – adjust operation to match the end-user’s typical daily schedule. After the commissioning, you can restrict access to the installer’s menu (manually or automatically after one hour) to avoid wrong manipulation of the unit by the end-user.

27

In case something goes wrong, full-text error messages guide the end-user to take appropriate action to try and resolve the problem. If the problem persists and a site intervention is necessary, the service engineer will be able to review the last 20 error occurrences, for simple diagnosis of the problem.

Detailed information on the operational conditions of the unit – such as the running hours of the different elements, operating temperatures or number of starts – can easily be read out from the extended end-user’s menu.

The user interface itself is equipped with a temperature sensor and can be installed remotely from the Daikin Altherma low temperature indoor unit.

› Installed on the unit: it allows quick and easy access to the unit’s operating information and settings.

› Installed remotely (e.g. living room): it also acts as a room thermostat – but with advanced features that provide more stable room temperatures, increased efficiency and operation life cycle. A second optional interface can still be installed on the unit for service purposes.

Room thermostat:

The Daikin user interface can be installed in the living room using the room thermostat function, which can additionally lower or raise the set-point water temperature depending on the actual room temperature, to even better match the set-point room temperature.

Graphical screen with backlight

On/Off

Menu back

Navigational buttons

Confirm

Home

Info

f. Room temperature control functionality

2.Integrated solar unit and domestic hot water tank

maximising renewable energyand offering top comfort for hot water preparation

28

Best seasonal efficiencies

The integrated solar unit uses free

energy from the sun to provide

domestic hot water and space

heating support. Solar energy and

heat pumps complement each other

ideally in this application. Depending

on your customer’s needs, you can

offer an a pressureless (drain-back)

or pressurised solar system. The

integrated solar unit based on a

lightweight plastic tank and can be

combined with a secondary heat

source. And end users can control the

unit easily via a smartphone app.

29

Integrated solar unit

The integrated solar unit uses free energy from the sun to produce domestic hot water and space heating.

Thanks to the extremely high efficiency of our flat solar collector up to 80% of solar energy can be converted into usable heat. In this application solar energy and heat pumps complement each other ideally: the heat pump adds the required amount of heat to the system to meet the demand.

Offer a drain-back or pressurised system depending on your customers‘ needs.

Drain-back solar system (with EHSH(X)-A) If the constructional conditions permit, recommend the direct drain-back system. In this system, the water in the storage tank is supplied directly and without heat exchanger to the solar collectors, heated and then stored. This process considerably increases the efficiency of the entire system, especially the solar collectors. Because the system is not pressurised, there is no need for an expansion tank, pressure relief valve, pressure gauge or heat exchanger.

A fully-automatic controller independently manages the solar system to provide optimum use of solar energy. The solar collectors are only filled if there is sufficient energy from the sun, and if the thermal storage tank can absorb the heat. When energy from the sun is insufficient, or the thermal storage tank can not absorb more heat, then the feed pump switches off, and the entire solar system drains into the thermal storage tank. Because of this process, this system does not require antifreeze. The connection pipes in the building and on the roof must be installed with a constant gradient. If a constant

3.000

2.500

2.000

1.500

1.000

500

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

kWh

The graphic shows when and how much the solar system supports the hot water and heating generation.

Combined with a heat pump, which also exploits regenerative ambient energy, the use of ancillary energy is reduced to an absolute minimum – saving costs for your customer.

gradient is not possible, then a pressurised solar system is a better solution.

Pressurised solar system (with EHSH(X)B-A) The pressurised solar system is easy to install and suitable for any application, in any building. It operates efficiently and safely at all pipe lengths and feed heights. The structure of the solar thermal storage tank is engineered so that an additional plate heat exchanger is not necessary. A bivalent heat exchanger for pressurised solar or other heat sources is already incorporated, making the system simple and flexible.

Unpressurised solar system Pressurised solar system

ON ON

Solar energy utilisation for hot water and heating

Heat pump (environmental heat)

Auxiliary energy

a. Solar support of domestic hot water and heating with unpressurised (drain-back) or pressurised solar system

30

Integrated solar unit

Using state-of-the-art technology, the integrated domestic hot water tank is water-hygienic. Thanks to the flow-through design, legionella bacteria cannot grow, thus eliminating the need for a thermal disinfection cycle. The exceptional water

hygiene benefits have been confirmed in an extensive study by the Hygiene Institute at the University of Tübingen – ensuring your installation is a safe one.

b. Lightweight tank with exceptional hygienic benefits

c. Bivalent option: combinable with a secondary heat source (EHSH(X)B-A only)

d. Easy app control

Heat from other sources can also be efficiently stored in the indoor unit. The solar system can be supported by oil-fired and gas-fired boilers, pellet-fired boilers or wood-fired stoves with boilers for heating and

hot water generation. If you are not installing a solar system from the beginning, it can be fitted quickly and easily at any time afterwards.

1. Control with the app

Simple, consistent handling can be carried out via a smartphone app. You’ll find it easy to use, thanks to the intuitive menu navigation and control.

2. Clear display and easy modification

The display shows values and parameters in clear text. All operating modes, timer programmes and operating parameters can be set and modified quickly.

3. Simple controller for easy regulation

The water temperature for heating is regulated according to the outdoor temperature. The controller automatically detects winter and summer, and switches the heating mode on and off to suit demand. The controller is easy and intuitive to operate and can be extended with a room controller, allowing the end user to conveniently control and monitor the heating system.

Excellent package label ratings with solar

Hooking up a solar thermal system is the most effective way to reach a higher

overall system efficiency class. The EKHWP-B domestic hot water tank is already

optimised for hooking up with a solar thermal system and in combination with

a solar collector, this system will become your own personal solar heater.

31

3.Wall mounted unit

offering flexibility for installation and domestic hot water connection

32

For some of your customers

the alternative set-up of

the wall-mounted indoor

unit will be the perfect

solution. The indoor unit

– including all hydraulic

components – can be

combined with a separate

domestic hot water tank.

33

Wall mounted unit

1. No domestic hot water is required in combination with the Daikin Altherma system

› No need to look for third-party components. All hydraulic components are included in the heat pump unit (circulating pump, expansion vessel, back-up heater, etc.).

› Easy serviceability: all hydraulic components and the PCB board are accessible from the front.

› Very compact: 890 mm (height) x 480 mm (width) x 344 mm (depth).

› Only a small installation space needed: almost no side clearances are required.

› Modern design: easily fits with other modern household appliances.

2. When combined with a separate domestic hot water tank is needed.

The domestic hot water tank is connectable to

› EKHWS stainless steel tank: 150l, 200l or 300l. › EKHWE enameled tank: 150l, 200l or 300l.

a. Flexible solutions

34

PCB board

Heat exchanger

Water pump

Expansion vessel

Wall mounted unit

3. When a solar connection for hot water is required:

Averaged over an entire year, the sun delivers half of the energy we need to bring our domestic hot water up to the desired temperature. High efficiency collectors with highly selective coating transform all the short-wave solar radiation into heat. The collectors can be mounted on virtually any kind of roof (on roof, in roof, flat roof ).

Drain-back solar system › The simplest and most efficient system. › The solar collectors are only filled with water when

there is enough solar heat. › The pump switches on briefly and fills the

collectors with storage tank water. › The fully-automatic controller manages the

solar system independently to provide optimum utilisation of the solar energy

› The system drains the water to the storage tank when not needed.

› No expansion tank, pressure relief valve, pressure gauge, heat exchanger and antifreeze required.

Pressurised solar system › System is filled with heat transfer fluid with

the correct amount of antifreeze to avoid freezing in winter.

› System is pressurised. › Operates safely and efficiently with any length of

pipe or feed height. › A bivalent heat exchanger makes the system

highly flexible.

ON ON

Drain-back

solar system

Pressurised

solar system

Excellent package label ratings with solar

Hooking up a solar thermal system is the most effective way to reach a higher

overall system efficiency class. The EKHWP-B domestic hot water tank is already

optimised for hooking up with a solar thermal system and in combination with

a solar collector, this system will become your own personal solar heater.

35

Wall mounted unit

36

b. Quick and easy commissioning

At the first start-up, a quick configuration wizard will guide you smoothly through the commissioning process. Through a series of short questions, the set-up of basic parameters will automatically be completed. You can fine-tune these parameters using the menu-based navigation. The quick configuration wizard ensures that only the parameter settings relevant to the installation will be shown in the menus. The irrelevant parameters remain hidden and thus inaccessible.

You can download the parameters to a PC as a back-up, or for duplication on similar installations. If preferred, you can prepare the parameter settings beforehand and upload them to the unit during commissioning.

› Before the actual test-run of the unit, an actuator test mode allows all the wired components to be activated one by one. This permits a quick and easy check of all connections and wiring to ensure correct operation.

› You can activate an automatic screed-drying function to proceed through a gradual heat-up of an under-floor heating system to avoid cracks in the floor during first use.

› Individual and easy-to-programme schedule timers – for heating, cooling, domestic hot water operation and recirculation, noise-sensitive operation and electrical booster heating – will adjust operation to match the end-user’s typical daily schedule.

› After the commissioning, access to the installer’s menu can be restricted (manually or automatically after one hour) to avoid wrong manipulation of the unit by the end-user.

Wall mounted unit

37

c. Easy serviceability

If something goes wrong, full-text error messages will guide the end-user to take appropriate action to try and resolve the problem. If the problem persists and a site intervention is necessary, the service engineer will be able to review the last 20 error occurrences – for easy diagnosis of the problem.

Detailed information on the operational conditions of the unit – such as the running hours of the different elements, operating temperatures or number of starts – can easily be read out from the extended end-user’s menu.

The user interface itself is equipped with a temperature sensor and can be installed remotely from the Daikin Altherma low temperature indoor unit.

› Installed on the unit, it will allow quick and easy access to the unit’s operating information and settings.

› Installed remotely (e.g. in a living room) it will also act as a room thermostat with more advanced features than a standard room thermostat, resulting in more stable room temperatures, increased efficiency and operation life cycle. A second optional interface can still be installed on the unit for service purposes.

Graphical screen with backlight

On/Off

Menu back

Navigational buttons

Confirm

Home

Info

d. Room temperature control functionality

4.Monobloc outdoor unit,

designed for low temperature applications

38

Daikin Altherma

low temperature monobloc has

been designed with installers

in mind. The result is our most

compact monobloc ever,

all-in-one air-water heat pump

– small, light and easy to handle.

39

Daikin Altherma low temperature monobloc

360 mm1085 mm

735

mm

a. A natural fit

40

Wiring centre

user interface

Domestic hot water

Hot water tankOutdoor

unit

3 way valve

Under floor heating

Wiring centre1. All hydraulic components are combined in the outdoor unit

Available in 5kW and 7kW models, the new Daikin Altherma LT monobloc requires only a controller indoors, when space heating is needed For use of both space heating and domistic hot water, a wiring centre is added. And the outdoor unit can be installed almost anywhere, under a window sill, or in the smallest of gardens. So it’s a natural fit for new build and renovation projects alike.

2. The space-saving design is ideal for homes where space is limited

› The outdoor unit includes all hydraulic components

› Smallest installed volume in the market: H735 x W1085 x D360 mm – only 80 kg

› The separate installation of controller and wiring centre allows a flexible installation in the house.

3. Everything you need from one source

The Daikin Altherma monobloc works efficiently with Daikin’s range of under-floor heating, radiators and fan convectors and can be combined with solar thermal systems. So you can count on Daikin for your entire project.

Daikin Altherma low temperature monobloc

41

Outdoor unit

Hot water tank

Radiators

Daikin Altherma low temperature monobloc

42

b. Easy to install, only water connection needed from the outdoor to the indoor

Expansion vessel (7l)Protects the closed water circuit from excessive water pressure caused by thermal expansion.

Manual air purge with flexibleEliminates residual air in the water circuit.

PumpPWM (pulse width modulation) pump is a high efficiency pump as speed is according to the temperature difference between the set temperature and actual indoor temperature rather than fixed speeds e.g. H/M/L

Pressure Relief ValveHelps in controlling the water pressure in the heating system. When calibrated pressure is reached, the valve will open and discharge to atmosphere. Prevents

that the system reaches dangerous levels of pressure

Clip-on filterProtects the plate heat exchanger,

pump, etc. against particles that can cause blockage.

Plate heat exchangerTransfers the heat from the low temperature side to the high temperature side.Heating: Refrigerant side = High temperature Water side = Low temperature Cooling: Refrigerant side = Low temperature Water side = High temperature

Flow sensorMeasures the flow in the water circuit.

Will stop the unit if no or a too low flow is detected.

1. Easy installation out of the box, with no refrigerant handling

The Daikin Altherma monobloc heat pump can be installed easily. It has a sealed refrigerant circuit, so no refrigerant handling or F-gas qualifications are required. With only water connections to the outdoor unit, limited wiring, and key hydraulic components inside the unit, it works right out of the box. This reduces the risk of installation errors and avoids the need to buy a separate expansion vessel, pump or isolation valves. Complete your projects with no surprises and maximise your profits on the job.

2. Easy serviceability, thanks to user-friendly interface putting complete control at your fingertips

In case something goes wrong, full-text errormessages guide the end-user to take appropriateaction to try and resolve the problem. If the problempersists and a site intervention is necessary,the service engineer will be able to review the last20 error occurrences, for simple diagnosis ofthe problem.

Detailed information on the operational conditions ofthe unit – such as the running hours of the differentelements, operating temperatures or number of starts – can easily be read out from the extended end-user’s menu.

Daikin Altherma low temperature monobloc

Example of monobloc outdoor unit - space heating

EBLQ05CAV3

55°C

4 kW

4 kW

4 kW

A++

35°C

4 kW

4 kW

5 kW

A++

61 dB

0 dB

43

c. High efficiency in all climates

Low voltage

High voltage

Main power supply

Water inlet

Water outlet

Free hanging coil

1. Market leading energy efficiencies minimise running costs

Daikin Altherma monobloc is setting new standards of efficiency with high SCOPs in all conditions Its new inverter compressor has a wide modulation range, giving lower minimum outputs at higher ambient temperatures. So the system works in partial load for most of the year. This reduces the load on the compressor, minimising running costs and maximising the system’s lifespan.

2. Optimised for all climates all year round, with operation guaranteed down to -25°C

With flow temperatures of up to 55°C even during cold weather, Daikin Altherma monobloc delivers higher heating capacity than any previous model at lower ambient temperatures (less than 10% drop off in heating capacity at -2°C), making it easier to select the right heat pump. A free hanging coil minimises frost build up and reliable operation is guaranteed down to -25°C outside. An optional back-up heater is also available – for total customer peace of mind. With just a simple annual inspection, you can count on the Daikin Altherma monobloc to run reliably, year after year.

Servicing

Servicing made easy

for long and trouble-free operation

Daikin Altherma low temperature heat pump systems have an unsurpassed reputation for reliability. To ensure that your customers benefit from years of dependable operation, our units are carefully designed to make any necessary troubleshooting, repair and maintenance as quick and easy as possible.

a. Troubleshooting

44

1. A smart system controller facilitates diagnostics and serviceability

In case something goes wrong, full-text error messages guide the end-user to take appropriate action to try and resolve the problem. If the problem persists and a site intervention is necessary, the service engineer will be able to review the last 20 error occurrences, for simple diagnosis of the problem.

Detailed information on the operational conditions of the unit – such as the running hours of the different elements, operating temperatures or number of starts – can easily be read out from the extended end-user’s menu. The 60 different full-text error codes provide the servicing engineer with very detailed information about the functioning of the unit, facilitating a rapid resolution of the problem.

PAS OP beeld LR

Servicing

b. Repair

c. Maintenance

45

1. To facilitate repairs, units are carefully designed for easy accessibility

In designing our indoor and outdoor Daikin Altherma low temperature heat pump systems we have made sure you can access all piping and electronics to make repairs as easily and rapidly as possible.

› All water and refrigerant connections are designed in such a manner that they are easy to connect and accessed.

› This makes servicing easy and avoids the risk of damage.

1. State-of-the-art design and exceptional build quality ensure that maintenance procedures are kept to the minimum

› The state-of-the-art design and exceptional build quality of our indoor and outdoor systems ensure that maintenance procedures are kept to a minimum – and can be done quickly and efficiently. The easy-access design will certainly make your job easier.

2. Full support from Daikin is offered for spare parts and assistance

If repair becomes necessary, Daikin backs you up with full support regarding spare parts and responsive, expert assistance in accordance to the standard procedures for refrigerant and pipe work.

2. Annual maintenance tasks to keep the system running smoothly

› To ensure that your customer’s Altherma low temperature system operates smoothly and at the highest possible efficiency levels, here is a list of the key maintenance items that should be checked on an annual basis.

› Fluid pressure of space heating circuit › Relief valve hose › Pressure relief valve of space heating circuit › Pressure relief valve of domestic hot water tank › Filters › Draining of the domestic hot water tank › Anode › Descaling and chemical disinfection › Switch box › Domestic hot water tank booster heater

(in case non-integrated tank)

Geen HR beeld gekregen

Daikin provides a web-based tool you and your customer can use to get a quick estimation of savings on both running costs and CO2 emissions. Based on a few inputs from your customer (location, house type,

The Daikin Altherma simulation software can evaluate every specific application and appropriate heat pump selection, taking into account the needs of the building and specific climate data. You simply provide the following data, and the software does the rest!

› House application: heat/cool load, water temperatures, power supply

› Climate conditions: location, design temperature › Domestic hot water requirements: tank volume,

material, solar connection › Preferences: “heating off“ temperature, night

setback function

Based on the specific house and location details, the software provides a full dimensioning – assuring your correct material selection.

As well as a full material selection, the software

provides detailed information for you and your customer, about the expected outcome of the specified Daikin Altherma unit, for its specific application and climate:

› Seasonal efficiency of the heat pump system › Amount of back-up heater operation › Energy consumption and energy cost per month › Savings on running costs compared to traditional

heating systems

All this information in summarised in a detailed report.

Energy savings calculator

Go to ecocalc.daikin.eu and see how a Daikin Altherma heat pump saves on both running costs and CO

2

emission.

* Simulation for a new build detached house (room in roof ) with low temperature emitters, for 4 people and a heated surface of 125m2, taking into account Belgian climate conditions, an electricity price of 0.17EUR/kWh and a gas price of 0.06 EUR/kWh.

floor area, number of people), a comparison is made between the Daikin Altherma heat pump system and traditional heating systems, including space heating and domestic hot water heating. This is available for both new builds and refurbishment applications.

Heat pump

in practice

Daikin helps its partners to meet their obligations re-garding the Ecodesign Directive and energy labelling. Labels and product fiches for each individual product, as well as for combined packages, are part of the standard delivery. As of September 2015, they will be available as downloads at any time from the Energy Label Generator at www.daikineurope.com/energylabel/lot1_2/Daikin. With our system configurator, individual solutions can be put together quickly and easily using Daikin system components – including corresponding package

labels. Comprehensive information materials and training courses at our Info Centers across Europe pro-vide in-depth expertise and ensure that our specialist partners can advise their customers competently on all issues around the energy efficiency of heaters.

46

a. Example of running cost and CO2 comparison

b. Simulation software

c. Free Access Website

Technical

specifications

47

1. Floor standing unit

Efficiency data EHVH + ERLQ04S18CB3V+ 004CV3

08S18CB3V / 08S26CB9W

+ 006CV3

08S18CB3V /08S26CB9W

+ 008CV3

11S18CB3V /11S26CB9W

+ 011CV3

16S18CB3V /16S26CB9W

+ 014CV3

16S18CB3V /16S26CB9W

+ 016CV3

11S18CB3V /11S26CB9W+ 011CW1

16S18CB3V /16S26CB9W+ 014CW1

16S18CB3V /16S26CB9W+ 016CW1

Heating capacity Nom. kW 4.40 / 4.03 6.00 / 5.67 7.40 / 6.89 11.20 / 11.00 14.50 / 13.60 16.00 / 15.20 11.20 / 11.00 14.50 / 13.60 16.00 / 15.20Power input Heating Nom. kW 0.87 / 1.13 1.27 / 1.59 1.66 / 2.01 2.43 / 3.10 3.37 / 4.10 3.76 / 4.66 3.42 / 4.21 3.37 / 4.10 3.76 / 4.66COP 5.04 / 3.58 4.74 / 3.56 4.45 / 3.42 4.60 / 2.75 / 3.55 / 2.10 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09 4.60 / 2.75 / 3.55 / 2.10 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09Domestic hot water heating

General Declared load profile L XL L XL L XL L XL L XL L XL L XL L XLAverage climate ηwh (water heating efficiency) % 95 86 90 86 90 87 98 87 98 87 98 87 98 87 98 87 98

Water heating energy efficiency class ASpace heating Average climate water

outlet 55°CGeneral ηs (Seasonal space heating efficiency) % 125 124 126 124 120 122 124 120 122

SCOP 3.20 3.17 3.23 3.18 3.07 3.13 3.18 3.07 3.13Seasonal space heating eff. class A++ A+ A++ A+

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % -SCOP 4.52 4.27 4.34 3.95 3.83 3.84 3.95 3.83 3.84Seasonal space heating eff. class -

Indoor Unit EHVH 04S18CB3V 08S18CB3V /08S26CB9W11S18CB3V

11S26CB9W16S18CB3V /16S26CB9W

11S18CB3V /11S26CB9W

16S18CB3V / 16S26CB9W

Casing Colour WhiteMaterial Precoated sheet metal

Dimensions Unit HeightxWidthxDepth mm 1,732x600x728Weight Unit kg 116 117 127 117 127 117 126 118 128 118 128 117 126 118 128 118 128Tank Water volume l 180 260 180 260 180 260 180 260 180 260 180 260 180 260 180 260

Maximum water temperature °C 65Maximum water pressure bar 10Corrosion protection Anode

Operation range Heating Water side Min.~Max. °C 15~55 15~55Domestic hot water Water side Min.~Max. °C 25~60 25~60 / 60

Refrigerant Charge TCO₂eq -GWP -

Sound power level Nom. dBA 42 44 42 44Sound pressure level Nom. dBA 28 30 28 30

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113 114Compressor Quantity 1

Type Hermetically sealed swing compressor Hermetically sealed scroll compressorOperation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0

Domestic hot water Min.~Max. °CDB -25~35 -20~35Refrigerant Type R-410A

Charge kg 1.5 1.6 3.4TCO₂eq 3.1 3.3 7.1

GWP 2,087.5Control Expansion valve (electronic type)

Sound power level Heating Nom. dBA 61 62 64 66 64 66Cooling Nom. dBA 63 64 66 69 64 66 69

Sound pressure level Heating Nom. dBA 48 49 51 52 51 52Cooling Nom. dBA 48 49 50 50 52 54 50 52 54

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommended fuses A 16 20 40 20

EHVH-CB + ERLQ-CV3/CW1

Specifications

48

Efficiency data EHVH + ERHQ11S26CB9W

+ 011BV311S18CB3V + 011BV3

16S26CB9W + 014BV3

16S18CB3V + 014BV3

16S26CB9W + 016BV3

16S18CB3V + 016BV3

11S26CB9W + 011BW1

11S18CB3V + 011BW1

16S26CB9W + 014BW1

16S18CB3V + 014BW1

16S26CB9W + 014BV3

16S18CB3V + 014BV3

Heating capacity Nom. kW 11.20 / 10.30 14.00 / 13.10 16.00 / 15.20 11.32 / 10.98 14.50 / 13.57 16.05 / 15.11Power input Heating Nom. kW 2.55 / 3.17 3.26 / 4.04 3.92 / 4.75 2.63 / 3.24 3.42 / 4.21 3.82 / 4.69COP 4.39 / 3.25 4.29 / 3.24 4.08 / 3.20 4.30 / 3.39 4.24 / 3.22 4.20 / 3.22Domestic hot water heating

General Declared load profile XL L XL L XL L XL L XL L XL LAverage climate ηwh (water heating efficiency) % 95 91 95 91 95 91 87 84 87 84 87 84

Water heating energy efficiency class ASpace heating Average climate water

outlet 55°CGeneral ηs (Seasonal space heating efficiency) % 114 113 115 117 116 118

SCOP 2.93 2.91 2.94 3.00 2.98 3.03Seasonal space heating eff. class A+

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % -SCOP 3.02 3.32 3.25 3.24 3.14 3.10Seasonal space heating eff. class -

Indoor Unit EHVH 11S26CB9W 11S18CB3V 16S26CB9W 16S18CB3V 16S26CB9W 16S18CB3V 11S26CB9W 11S18CB3V 16S26CB9W 16S18CB3V 16S26CB9W 16S18CB3VCasing Colour White

Material Precoated sheet metalDimensions Unit HeightxWidthxDepth mm 1,732x600x728Weight Unit kg 126 117 127 118 127 118 126 117 127 118 127 118Tank Water volume l 260 180 260 180 260 180 260 180 260 180 260 180

Maximum water temperature °C 65Maximum water pressure bar 10Corrosion protection Anode

Operation range Heating Water side Min.~Max. °C 15~55Domestic hot water Water side Min.~Max. °C 25~60 / 60

Refrigerant Charge TCO₂eq -GWP -

Sound power level Nom. dBA 42 44 42 44Sound pressure level Nom. dBA 28 30 28 30

Outdoor Unit ERHQ 011BV3 014BV3 016BV3 011BW1 014BW1 016BW1Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320Weight Unit kg 102 108Compressor Quantity 1

Type Hermetically sealed scroll compressorOperation range Cooling Min.~Max. °CDB 10.0~46.0

Domestic hot water Min.~Max. °CDB -20~35Refrigerant Type R-410A

Charge kg 2.7 3.0TCO₂eq 5.6 6.3

GWP 2,087.5Control Expansion valve (electronic type)

Sound power level Heating Nom. dBA 64 66 64 66Cooling Nom. dBA 64 66 69 64 66 69

Sound pressure level Heating Nom. dBA 49 51 53 51 52Cooling Nom. dBA 50 52 54 50 52 54

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommended fuses A 32 20

EHVH-CB + ERHQ-BV3/ERHQ-BW1

Efficiency data EHVX + ERLQ04S18CB3V+ 004CV3

08S18CB3V /08S26CB9W

+ 006CV3

08S18CB3V /08S26CB9W

+ 008CV3

11S18CB3V /11S26CB9W

+ 011CV3

16S18CB3V /16S26CB9W

+ 014CV3

16S18CB3V /16S26CB9W

+ 016CV3

11S18CB3V /11S26CB9W+ 011CW1

16S18CB3V /16S26CB9W+ 014CW1

16S18CB3V /16S26CB9W+ 016CW1

Heating capacity Nom. kW 4.40 / 4.03 6.00 / 5.67 7.40 / 6.89 11.20 / 11.00 14.50 / 13.60 16.00 / 15.20 11.20 / 11.00 14.50 / 13.60 16.00 / 15.20Cooling capacity Nom. kW 4.1 / 4.2 5.9 / 4.8 6.2 / 5.4 12.1 / 11.7 12.7 / 12.6 13.8 / 13.1 12.1 / 11.7 12.7 / 12.6 13.8 / 13.1Power input Heating Nom. kW 0.87 / 1.13 1.27 / 1.59 1.66 / 2.01 2.43 / 3.10 3.37 / 4.10 3.76 / 4.66 2.43 / 3.10 3.37 / 4.10 3.76 / 4.66

Cooling Nom. kW 0.90 / 1.80 1.51 / 2.07 1.64 / 2.34 3.05 / 4.31 3.21 / 5.08 3.74 / 5.73 3.05 / 4.31 3.21 / 5.08 3.74 / 5.73COP 5.04 / 3.58 4.74 / 3.56 4.45 / 3.42 4.60 / 2.75 / 3.55 / 2.10 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09 4.60 / 2.75 / 3.55 / 2.10 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09EER 4.55 / 2.32 3.89 / 2.34 3.79 / 2.29 3.98 / 2.72 3.96 / 2.47 3.69 / 2.29 3.98 / 2.72 3.96 / 2.47 3.69 / 2.29Domestic hot water heating

General Declared load profile L XL L XL L XL L XL L XL L XL L XL L XLAverage climate ηwh (water heating efficiency) % 95 86 90 86 90 87 98 87 98 87 98 87 98 87 98 87 98

Water heating energy efficiency class ASpace heating Average climate water

outlet 55°CGeneral ηs (Seasonal space heating efficiency) % 125 124 126 124 120 122 124 120 122

SCOP 3.20 3.17 3.23 3.18 3.07 3.13 3.18 3.07 3.13Seasonal space heating eff. class A++ A+ A++ A+

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % -SCOP 4.52 4.27 4.34 3.95 3.83 3.84 3.95 3.83 3.84Seasonal space heating eff. class -

Indoor Unit EHVX 04S18CB3V 08S18CB3V / 08S26CB9W11S18CB3V /11S26CB9W

16S18CB3V / 16S26CB9W11S18CB3V /11S26CB9W

16S18CB3V / 16S26CB9W

Casing Colour WhiteMaterial Precoated sheet metal

Dimensions Unit HeightxWidthxDepth mm 1,732x600x728Weight Unit kg 117 119 129 119 129 119 128 120 130 120 130 119 128 120 130 120 130Tank Water volume l 180 260 180 260 180 260 180 260 180 260 180 260 180 260 180 260

Maximum water temperature °C 65Maximum water pressure bar 10Corrosion protection Anode

Operation range Heating Water side Min.~Max. °C 15~55 15~55Cooling Water side Min.~Max. °C 5~22Domestic hot water Water side Min.~Max. °C 25~60 25~60 / 60

Refrigerant Charge TCO₂eq -GWP -

Sound power level Nom. dBA 42 44 42 44Sound pressure level Nom. dBA 28 30 28 30

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113 114Compressor Quantity 1

Type Hermetically sealed swing compressor Hermetically sealed scroll compressorOperation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0

Domestic hot water Min.~Max. °CDB -25~35 -20~35Refrigerant Type R-410A

Charge kg 1.5 1.6 3.4TCO₂eq 3.1 3.3 7.1

GWP 2,087.5Control Expansion valve (electronic type)

Sound power level Heating Nom. dBA 61 62 64 66 64 66Cooling Nom. dBA 63 64 66 69 64 66 69

Sound pressure level Heating Nom. dBA 48 49 51 52 51 52Cooling Nom. dBA 48 49 50 50 52 54 50 52 54

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommended fuses A 16 20 40 20

EHVX-CB + ERLQ-CV3/ERLQ-CW1

Specifications

49

Specifications

50

Efficiency data EHVX + ERHQ11S18CB3V + 011BV3

11S26CB9W + 011BV3

16S18CB3V + 014BV3

16S26CB9W + 014BV3

16S18CB3V + 016BV3

16S26CB9W + 016BV3

11S18CB3V + 011BW1

11S26CB9W + 011BW1

16S18CB3V + 014BW1

16S26CB9W + 014BW1

16S18CB3V + 016BW1

16S26CB9W + 016BW1

Heating capacity Nom. kW 11.20 / 10.30 14.00 / 13.10 16.00 / 15.20 11.32 / 10.98 14.50 / 13.57 16.05 / 15.11Cooling capacity Nom. kW 13.9 / 10.0 17.3 / 12.5 17.8 / 13.1 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1Power input Heating Nom. kW 2.55 / 3.17 3.26 / 4.04 3.92 / 4.75 2.63 / 3.24 3.42 / 4.21 3.82 / 4.69

Cooling Nom. kW 3.86 / 3.69 5.86 / 5.69 6.87 / 5.95 4.53 / 4.31 5.43 / 5.08 6.16 / 5.73COP 4.39 / 3.25 4.29 / 3.24 4.08 / 3.20 4.30 / 3.39 4.24 / 3.22 4.20 / 3.22EER 3.60 / 2.71 2.95 / 2.32 2.59 / 2.20 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29Domestic hot water heating

General Declared load profile L XL L XL L XL L XL L XL L XLAverage climate ηwh (water heating efficiency) % 91 95 91 95 91 95 84 87 84 87 84 87

Water heating energy efficiency class ASpace heating Average climate water

outlet 55°CGeneral ηs (Seasonal space heating efficiency) % 114 113 115 117 116 118

SCOP 2.93 2.91 2.94 3.00 2.98 3.03Seasonal space heating eff. class A+

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % -SCOP 3.02 3.32 3.25 3.24 3.14 3.10Seasonal space heating eff. class -

Indoor Unit EHVX 11S18CB3V 11S26CB9W 16S18CB3V 16S26CB9W 16S18CB3V 16S26CB9W 11S18CB3V 11S26CB9W 16S18CB3V 16S26CB9W 16S18CB3V 16S26CB9WCasing Colour White

Material Precoated sheet metalDimensions Unit HeightxWidthxDepth mm 1,732x600x728Weight Unit kg 119 128 120 129 120 129 119 128 120 129 120 129Tank Water volume l 180 260 180 260 180 260 180 260 180 260 180 260

Maximum water temperature °C 65Maximum water pressure bar 10Corrosion protection Anode

Operation range Heating Water side Min.~Max. °C 15~55Cooling Water side Min.~Max. °C 5~22Domestic hot water Water side Min.~Max. °C 25~60 / 60

Refrigerant Charge TCO₂eq -GWP -

Sound power level Nom. dBA 42 44 42 44Sound pressure level Nom. dBA 28 30 28 30

Outdoor Unit ERHQ 011BV3 014BV3 016BV3 011BW1 014BW1 016BW1Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320Weight Unit kg 102 108Compressor Quantity 1

Type Hermetically sealed scroll compressorOperation range Cooling Min.~Max. °CDB 10.0~46.0

Domestic hot water Min.~Max. °CDB -20~35Refrigerant Type R-410A

Charge kg 2.7 3.0TCO₂eq 5.6 6.3

GWP 2,087.5Control Expansion valve (electronic type)

Sound power level Heating Nom. dBA 64 66 64 66Cooling Nom. dBA 64 66 69 64 66 69

Sound pressure level Heating Nom. dBA 49 51 53 51 52Cooling Nom. dBA 50 52 54 50 52 54

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommended fuses A 32 20

EHVX-CB + ERHQ-BV3/ERHQ-BW1

Specifications

51

Efficiency data EHVZ + ERLQ04S18CB3V +

004CV308S18CB3V +

006CV308S18CB3V +

008CV316S18CB3V +

011CV316S18CB3V +

014CV316S18CB3V +

016CV316S18CB3V +

011CW116S18CB3V +

014CW116S18CB3V +

016CW1Heating capacity Nom. kW 4.40 / 4.03 6.00 / 5.67 7.40 / 6.89 11.20 / 11.00 14.40 / 13.50 15.90 / 15.10 11.20 / 11.00 14.40 / 13.50 15.90 / 15.10Power input Heating Nom. kW 0.87 / 1.13 1.27 / 1.59 1.66 / 2.01 2.43 / 3.10 3.39 / 4.12 3.77 / 4.67 2.43 / 3.10 3.39 / 4.12 3.77 / 4.67COP 5.04 / 3.58 4.74 / 3.56 4.45 / 3.42 4.60 / 2.75 / 3.55 / 2.10 4.24 / 2.61 / 3.28 / 2.05 4.22 / 2.61 / 3.23 / 2.07 4.60 / 2.75 / 3.55 / 2.10 4.24 / 2.61 / 3.28 / 2.05 4.22 / 2.61 / 3.23 / 2.07Pump Additional Zone Nominal ESP unit (*RLQ*C*) Heating kPa 52.3 / 55.4 40.6 / 43.3 28.3 / 32.7 26.2 / 28.3 25.0 26.2 / 28.3 25.0Pump Main Zone Nominal ESP unit (*RLQ*C*) Heating kPa 48.6 / 51.9 39.5 / 42.3 26.4 / 31.2 18.2 / 20.7 25.0 18.2 / 20.7 25.0Domestic hot water heating

General Declared load profile LAverage climate ηwh (water heating efficiency) % 95 86 87

Water heating energy efficiency class ASpace heating Average climate water

outlet 55°CGeneral ηs (Seasonal space heating efficiency) % 125 124 126 124 120 122 124 120 122

SCOP 3.20 3.17 3.23 3.18 3.07 3.18 3.07Seasonal space heating eff. class A++ A+ A++ A+

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % -SCOP 4.52 4.27 4.34 3.95 3.83 3.84 3.95 3.83 3.84Seasonal space heating eff. class -

Indoor Unit EHVZ 04S18CB3V 08S18CB3V 16S18CB3VCasing Colour White

Material Precoated sheet metalDimensions Unit HeightxWidthxDepth mm 1,732x600x728Weight Unit kg 121 122 121Tank Water volume l 180

Maximum water temperature °C 65Maximum water pressure bar 10Corrosion protection Anode

Operation range Heating Water side Min.~Max. °C 15~55 15~55Domestic hot water Water side Min.~Max. °C 25~60 25~60 / 60

Refrigerant Charge TCO₂eq -GWP -

Sound power level Nom. dBA 42 44Sound pressure level Nom. dBA 28 30

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113 114Compressor Quantity 1

Type Hermetically sealed swing compressor Hermetically sealed scroll compressorOperation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0

Domestic hot water Min.~Max. °CDB -25~35 -20~35Refrigerant Type R-410A

Charge kg 1.5 1.6 3.4TCO₂eq 3.1 3.3 7.1

GWP 2,087.5Control Expansion valve (electronic type)

Sound power level Heating Nom. dBA 61 62 64 66 64 66Cooling Nom. dBA 63 64 66 69 64 66 69

Sound pressure level Heating Nom. dBA 48 49 51 52 51 52Cooling Nom. dBA 48 49 50 50 52 54 50 52 54

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommended fuses A 16 20 40 20

EHVZ-CB3V + ERLQ-CV3/ERLQ-CW1

Specifications

52

Efficiency data EHVZ + ERHQ16S18CB3V + 011BV3

16S18CB3V + 014BV3

16S18CB3V + 016BV3

16S18CB3V + 011BW1

16S18CB3V + 014BW1

16S18CB3V + 016BW1

Heating capacity Nom. kW 11.20 / 10.30 14.00 / 13.10 16.00 / 15.20 11.32 / 10.98 14.50 / 13.57 16.05 / 15.11Power input Heating Nom. kW 2.55 / 3.17 3.26 / 4.04 3.92 / 4.75 2.63 / 3.24 3.42 / 4.21 3.82 / 4.69COP 4.39 / 3.25 4.29 / 3.24 4.08 / 3.20 4.30 / 3.39 4.24 / 3.22 4.20 / 3.22Pump Additional Zone Nominal ESP unit (*RHQ*B*) Heating kPa 26.2 / 35.0 25.0 24.8 / 28.3 25.0Pump Main Zone Nominal ESP unit (*RHQ*B*) Heating kPa 18.2 / 28.8 25.0 16.4 / 20.7 25.0Domestic hot water heating

General Declared load profile LAverage climate ηwh (water heating efficiency) % 91 84

Water heating energy efficiency class ASpace heating Average climate

water outlet 55°CGeneral ηs (Seasonal space heating efficiency) % 114 113 115 117 116 118

SCOP 2.93 2.91 2.94 3.00 2.98 3.03Seasonal space heating eff. class A+

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % -SCOP 3.02 3.32 3.25 3.24 3.14 3.10Seasonal space heating eff. class -

Indoor Unit EHVZ 16S18CB3VCasing Colour White

Material Precoated sheet metalDimensions Unit HeightxWidthxDepth mm 1,732x600x728Weight Unit kg 121Tank Water volume l 180

Maximum water temperature °C 65Maximum water pressure bar 10Corrosion protection Anode

Operation range Heating Water side Min.~Max. °C 15~55Domestic hot water Water side Min.~Max. °C 25~60 / 60

Refrigerant Charge TCO₂eq -GWP -

Sound power level Nom. dBA 44Sound pressure level Nom. dBA 30

Outdoor Unit ERHQ 011BV3 014BV3 016BV3 011BW1 014BW1 016BW1Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320Weight Unit kg 102 108Compressor Quantity 1

Type Hermetically sealed scroll compressorOperation range Cooling Min.~Max. °CDB 10.0~46.0

Domestic hot water Min.~Max. °CDB -20~35Refrigerant Type R-410A

Charge kg 2.7 3.0TCO₂eq 5.6 6.3

GWP 2,087.5Control Expansion valve (electronic type)

Sound power level Heating Nom. dBA 64 66 64 66Cooling Nom. dBA 64 66 69 64 66 69

Sound pressure level Heating Nom. dBA 49 51 53 51 52Cooling Nom. dBA 50 52 54 50 52 54

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommended fuses A 32 20

EHVZ-CB3V + ERHQ-BV3/BW1

Specifications

53

EHSH-A + ERLQ-CV3/ERLQ-CW1

Efficiency data EHSH + ERLQ04P30A +

004CV308P50A +

006CV308P30A +

006CV308P30A +

008CV308P50A +

008CV316P50A +

011CV316P50A +

014CV316P50A +

016CV316P50A +

011CW116P50A + 014CW1

16P50A + 016CW1

Heating capacity Nom. kW 4.53 / 3.98 / 4.26 / 3.47 6.06 / 5.78 / 5.14 / 4.60 7.78 / 7.27 / 5.53 / 5.51 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05Power input Heating Nom. kW 0.87 / 1.04 / 1.49 / 0.85 1.30 / 1.58 / 1.88 / 1.26 1.69 / 2.04 / 1.98 / 1.56 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 3.42 / 4.07 / 3.17 / 2.93COP 5.23 / 3.84 / 2.85 / 4.07 4.65 / 3.66 / 2.73 / 3.64 4.60 / 3.57 / 2.78 / 3.54 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15Domestic hot water heating

General Declared load profile L XL L XLAverage climate ηwh (water heating efficiency) % 103 102 98 90 96 83

Water heating energy efficiency class ASpace heating Average climate water

outlet 55°CGeneral ηs (Seasonal space heating efficiency) % 130 125 127 125 126 125 126 125

Seasonal space heating eff. class A++Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % -Seasonal space heating eff. class -

Indoor Unit EHSH 04P30A 08P50A 08P30A 08P50A 16P50ACasing Colour Traffic white (RAL9016) / Dark grey (RAL7011)

Material Impact resistant polypropyleneDimensions Unit HeightxWidthxDepth mm 1,945x615x595 1,945x790x790 1,945x615x595 1,945x790x790Weight Unit kg 87 114 87 114 116Tank Water volume l 300 500 300 500

Maximum water temperature °C 85Operation range Heating Ambient Min.~Max. °C -25~25 -25~35

Water side Min.~Max. °C 15~55 15~55 15~55 15~55Domestic hot water Ambient Min.~Max. °CDB -25~35

Water side Min.~Max. °C 25~55Refrigerant Type R-410A

Charge kg 1.5 1.6 3.4TCO₂eq -

Control Electronic expansion valve / InverterGWP -

Sound power level Nom. dBA 40Sound pressure level Nom. dBA 28

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113 114Compressor Quantity 1

Type Hermetically sealed swing compressor Hermetically sealed scroll compressorOperation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0

Domestic hot water Min.~Max. °CDB -25~35 -20~35Refrigerant Type R-410A

Charge kg 1.5 1.6 3.4TCO₂eq 3.1 3.3 7.1

GWP 2,087.5Control Expansion valve (electronic type)

Sound power level Heating Nom. dBA 61 62 64 66 64 66Cooling Nom. dBA 63 64 66 69 64 66 69

Sound pressure level Heating Nom. dBA 48 49 51 52 51 52Cooling Nom. dBA 48 49 50 50 52 54 50 52 54

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommended fuses A 16 20 40 20

2. Integrated solar unit

EHSHB-A + ERLQ-CV3/ERLQ-CW1

Specifications

Efficiency data EHSHB + ERLQ04P30A +

004CV308P30A +

006CV308P50A +

006CV308P30A +

008CV308P50A +

008CV316P50A +

011CV316P50A +

014CV316P50A +

016CV316P50A +

011CW116P50A + 014CW1

16P50A + 016CW1

Heating capacity Nom. kW 4.53 / 3.98 / 4.26 / 3.47 6.06 / 5.78 / 5.14 / 4.60 7.78 / 7.27 / 5.53 / 5.51 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05Power input Heating Nom. kW 0.87 / 1.04 / 1.49 / 0.85 1.30 / 1.58 / 1.88 / 1.26 1.69 / 2.04 / 1.98 / 1.56 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 3.42 / 4.07 / 3.17 / 2.93COP 5.23 / 3.84 / 2.85 / 4.07 4.65 / 3.66 / 2.73 / 3.64 4.60 / 3.57 / 2.78 / 3.54 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15Domestic hot water heating

General Declared load profile L XL L XL - XL -Average climate ηwh (water heating efficiency) % 103 98 108 90 99 - 84 - -

Water heating energy efficiency class A - A - -Space heating Average climate water

outlet 55°CGeneral ηs (Seasonal space heating efficiency) % 130 125 127 - 124 - -

Seasonal space heating eff. class A++ - A+ - -Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % - -Seasonal space heating eff. class - -

Indoor Unit EHSHB 04P30A 08P30A 08P50A 08P30A 08P50A 16P50ACasing Colour Traffic white (RAL9016) / Dark grey (RAL7011)

Material Impact resistant polypropyleneDimensions Unit HeightxWidthxDepth mm 1,945x615x595 1,945x790x790 1,945x615x595 1,945x790x790Weight Unit kg 92 119 92 119 121Tank Water volume l 300 500 300 500

Maximum water temperature °C 85Operation range Heating Ambient Min.~Max. °C -25~25 -25~35

Water side Min.~Max. °C 15~55 15~55 15~55 15~55 15~55Domestic hot water Ambient Min.~Max. °CDB -25~35

Water side Min.~Max. °C 25~55Refrigerant Type R-410A

Charge kg 1.5 1.6 3.4TCO₂eq -

Control Electronic expansion valve / InverterGWP -

Sound power level Nom. dBA 40Sound pressure level Nom. dBA 28

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113 114Compressor Quantity 1

Type Hermetically sealed swing compressor Hermetically sealed scroll compressorOperation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0

Domestic hot water Min.~Max. °CDB -25~35 -20~35Refrigerant Type R-410A

Charge kg 1.5 1.6 3.4TCO₂eq 3.1 3.3 7.1

GWP 2,087.5Control Expansion valve (electronic type)

Sound power level Heating Nom. dBA 61 62 64 66 64 66Cooling Nom. dBA 63 64 66 69 64 66 69

Sound pressure level Heating Nom. dBA 48 49 51 52 51 52Cooling Nom. dBA 48 49 50 50 52 54 50 52 54

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommended fuses A 16 20 40 20

54

EHSX-A + ERLQ-CV3/ERLQ-CW1

Specifications

55

Efficiency data EHSX + ERLQ04P30A +

004CV308P30A +

006CV308P50A +

006CV308P30A +

008CV308P50A +

008CV316P50A +

011CV316P50A +

014CV316P50A +

016CV316P50A +

011CW116P50A + 014CW1

16P50A + 016CW1

Heating capacity Nom. kW 4.53 / 3.98 / 4.26 / 3.47 6.06 / 5.78 / 5.14 / 4.60 7.78 / 7.27 / 5.53 / 5.51 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05Cooling capacity Nom. kW 4.4 / 4.0 5.2 / 4.6 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1Power input Heating Nom. kW 0.87 / 1.04 / 1.49 / 0.85 1.30 / 1.58 / 1.88 / 1.26 1.69 / 2.04 / 1.98 / 1.56 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 3.42 / 4.07 / 3.17 / 2.93

Cooling Nom. kW 1.05 / 1.41 1.43 / 1.85 4.55 / 4.30 5.44 / 5.10 6.18 / 5.72 4.55 / 4.30 5.44 / 5.10 6.18 / 5.72COP 5.23 / 3.84 / 2.85 / 4.07 4.65 / 3.66 / 2.73 / 3.64 4.60 / 3.57 / 2.78 / 3.54 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15EER 4.21 / 2.85 3.65 / 2.51 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29Domestic hot water heating

General Declared load profile L XL L XL - XL -Average climate ηwh (water heating efficiency) % 103 98 102 90 96 -

Water heating energy efficiency class A -Space heating Average climate water

outlet 55°CGeneral ηs (Seasonal space heating efficiency) % 132 126 128 -

Seasonal space heating eff. class A++ -Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % -Seasonal space heating eff. class -

Indoor Unit EHSX 04P30A 08P30A 08P50A 08P30A 08P50A 16P50ACasing Colour Traffic white (RAL9016) / Dark grey (RAL7011)

Material Impact resistant polypropyleneDimensions Unit HeightxWidthxDepth mm 1,945x615x595 1,945x790x790 1,945x615x595 1,945x790x790Weight Unit kg 87 114 87 114 116Tank Water volume l 300 500 300 500

Maximum water temperature °C 85Operation range Heating Ambient Min.~Max. °C -25~25 -25~35

Water side Min.~Max. °C 15~55 15~55 15~55 15~55 15~55Cooling Ambient Min.~Max. °CDB 10~43

Water side Min.~Max. °C 5~22 -~-Domestic hot water Ambient Min.~Max. °CDB -25~35

Water side Min.~Max. °C 25~55Refrigerant Type R-410A

Charge kg 1.5 1.6 3.4TCO₂eq -

Control Electronic expansion valve / InverterGWP -

Sound power level Nom. dBA 40Sound pressure level Nom. dBA 28

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113 114Compressor Quantity 1

Type Hermetically sealed swing compressor Hermetically sealed scroll compressorOperation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0

Domestic hot water Min.~Max. °CDB -25~35 -20~35Refrigerant Type R-410A

Charge kg 1.5 1.6 3.4TCO₂eq 3.1 3.3 7.1

GWP 2,087.5Control Expansion valve (electronic type)

Sound power level Heating Nom. dBA 61 62 64 66 64 66Cooling Nom. dBA 63 64 66 69 64 66 69

Sound pressure level Heating Nom. dBA 48 49 51 52 51 52Cooling Nom. dBA 48 49 50 50 52 54 50 52 54

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommended fuses A 16 20 40 20 20

EHSXB-A + ERLQ-CV3/ERLQ-CW1

Specifications

Efficiency data EHSXB + ERLQ04P30A +

004CV308P30A +

006CV308P50A +

006CV308P30A +

008CV308P50A +

008CV316P50A +

011CV316P50A +

014CV316P50A +

016CV316P50A +

011CW116P50A + 014CW1

16P50A +016CW1

Heating capacity Nom. kW 4.53 / 3.98 / 4.26 / 3.47 6.06 / 5.78 / 5.14 / 4.60 7.78 / 7.27 / 5.53 / 5.51 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05Cooling capacity Nom. kW 4.4 / 4.0 5.2 / 4.6 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1Power input Heating Nom. kW 0.87 / 1.04 / 1.49 / 0.85 1.30 / 1.58 / 1.88 / 1.26 1.69 / 2.04 / 1.98 / 1.56 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 3.42 / 4.07 / 3.17 / 2.93

Cooling Nom. kW 1.05 / 1.41 1.43 / 1.85 4.55 / 4.30 5.44 / 5.10 6.18 / 5.72 4.55 / 4.30 5.44 / 5.10 6.18 / 5.72COP 5.23 / 3.84 / 2.85 / 4.07 4.65 / 3.66 / 2.73 / 3.64 4.60 / 3.57 / 2.78 / 3.54 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15EER 4.21 / 2.85 3.65 / 2.51 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29Domestic hot water heating

General Declared load profile L XL L XL XLAverage climate ηwh (water heating efficiency) % 103 98 108 90 99 84 84

Water heating energy efficiency class A ASpace heating Average climate water

outlet 55°CGeneral ηs (Seasonal space heating efficiency) % 132 126 128 130 127 128 130 127

Seasonal space heating eff. class A++ A++Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % - -Seasonal space heating eff. class - -

Indoor Unit EHSXB 04P30A 08P30A 08P50A 08P30A 08P50A 16P50ACasing Colour Traffic white (RAL9016) / Dark grey (RAL7011)

Material Impact resistant polypropyleneDimensions Unit HeightxWidthxDepth mm 1,945x615x595 1,945x790x790 1,945x615x595 1,945x790x790Weight Unit kg 92 119 92 119 121Tank Water volume l 300 500 300 500

Maximum water temperature °C 85Operation range Heating Ambient Min.~Max. °C -25~25 -25~35

Water side Min.~Max. °C 15~55 15~55 15~55 15~55 15~55Cooling Ambient Min.~Max. °CDB 10~43

Water side Min.~Max. °C 5~22 -~-Domestic hot water Ambient Min.~Max. °CDB -25~35

Water side Min.~Max. °C 25~55Refrigerant Type R-410A

Charge kg 1.5 1.6 3.4TCO₂eq -

Control Electronic expansion valve / InverterGWP -

Sound power level Nom. dBA 40Sound pressure level Nom. dBA 28

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113 114Compressor Quantity 1

Type Hermetically sealed swing compressor Hermetically sealed scroll compressorOperation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0

Domestic hot water Min.~Max. °CDB -25~35 -20~35Refrigerant Type R-410A

Charge kg 1.5 1.6 3.4TCO₂eq 3.1 3.3 7.1

GWP 2,087.5Control Expansion valve (electronic type)

Sound power level Heating Nom. dBA 61 62 64 66 64 66Cooling Nom. dBA 63 64 66 69 64 66 69

Sound pressure level Heating Nom. dBA 48 49 51 52 51 52Cooling Nom. dBA 48 49 50 50 52 54 50 52 54

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommended fuses A 16 20 40 20

56

Specifications

57

3. Wall mounted unit

Efficiency data EHBH + ERLQ04CB3V + 004CV3

08CB9W + 006CV3

08CB9W + 008CV3

11CB3V/9W + 011CV3

16CB3V/9W+ 014CV3

16CB3V/9W + 016CV3

11CB3V/9W + 011CW1

16CB3V/9W + 014CW1

16CB3V/9W + 016CW1

Heating capacity Nom. kW 4.40 (1 / 4.03 (2 6.00 (1 / 5.67 (2 7.40 (1 / 6.89 (2 11.20 (1 / 11.00 (2 14.50 (1 / 13.60 (2 16.00 (1 / 15.20 (2 11.20 (1 / 11.00 (2 14.50 (1 / 13.60 (2 16.00 (1 / 15.20 (2Power input Heating Nom. kW 0.87 (1 / 1.13 (2 1.27 (1 / 1.59 (2 1.66 (1 / 2.01 (2 2.43 (1 / 3.10 (2 3.37 (1 / 4.10 (2 3.76 (1 / 4.66 (2 3.42 (1 / 4.21 (2 3.37 (1 / 4.10 (2 3.76 (1 / 4.66 (2COP 5.04 (1 /

3.58 (24.74 (1 / 3.56 (2

4.45 (1 / 3.42 (2

4.60 (1 / 2.75 (3 / 3.55 (2 / 2.10 (4

4.30 (1 / 2.65 (3 / 3.32 (2 / 2.08 (4

4.25 (1 / 2.64 (3 / 3.26 (2 / 2.09 (4

4.60 (1 / 2.75 (3 / 3.55 (2 / 2.10 (4

4.30 (1 / 2.65 (3 / 3.32 (2 / 2.08 (4

4.25 (1 / 2.64 (3 / 3.26 (2 / 2.09 (4

Domestic hot water heating

General Declared load profile -Average climate ηwh (water heating efficiency) % -

Water heating energy efficiency class -Space heating Average climate water

outlet 55°CGeneral ηs (Seasonal space heating efficiency) % 125 124 126 124 120 122 124 120 122

SCOP 3.20 3.17 3.23 3.18 3.07 3.13 3.18 3.07 3.13Seasonal space heating eff. class A++ A+ A++ A+

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % 178 168 171 155 150 155 150SCOP 4.52 4.27 4.34 3.95 3.83 3.84 3.95 3.83 3.84Seasonal space heating eff. class A+++ A++

Indoor Unit EHBH 04CB3V08CB3V/9W

08CB9W08CB3V/9W

08CB9W11CB3V/9W 16CB3V/9W 16CB3V/9W 11CB3V/9W 16CB3V/9W 16CB3V/9W

Casing Colour WhiteMaterial Precoated sheet metal

Dimensions Unit HeightxWidthxDepth mm 890x480x344Weight Unit kg 41 43 45 43 45 43 44 45 44 45 43 44 45 44 45Operation range Heating Water side Min.~Max. °C 15~55 15~55

Domestic hot water Water side Min.~Max. °C 25~80 25~80Refrigerant Charge TCO₂eq -

GWP -Sound power level Nom. dBA 40 41 44 41 44Sound pressure level Nom. dBA 26 27 30 27 30

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113 114Compressor Quantity 1

Type Hermetically sealed swing compressor Hermetically sealed scroll compressorOperation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0

Domestic hot water Min.~Max. °CDB -25 (2.000~35 (2 -20 (2.000~35 (2Refrigerant Type R-410A

Charge kg 1.5 1.6 3.4TCO₂eq 3.1 3.3 7.1

GWP 2,087.5Control Expansion valve (electronic type)

Sound power level Heating Nom. dBA 61 62 64 (3 66 (3 64 (3 66 (3Cooling Nom. dBA 63 64 (4 66 (4 69 (4 64 (4 66 (4 69 (4

Sound pressure level Heating Nom. dBA 48 (3 49 (3 51 (5 52 (5 51 (5 52 (5Cooling Nom. dBA 48 (3 49 (3 50 (3 50 (5 52 (5 54 (5 50 (5 52 (5 54 (5

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommended fuses A 16 20 40 20

Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

EHBH-CB + ERLQ-CV3/ERLQ-CW1

Specifications

58

EHBH-CB + ERHQ-BW1/ERHQ-BV3

Efficiency data EHBH + ERHQ11CB3V +

011BV311CB9W

+ 011BV316CB3V +

014BV316CB9W

+ 014BV316CB3V +

016BV316CB9W

+ 016BV311CB3V + 011BW1

11CB9W + 011BW1

16CB3V + 014BW1

16CB9W +

014BW1

16CB3V + 016BW1

16CB9W + 016BW1

Heating capacity Nom. kW 11.20 / 10.30 14.00 / 13.10 16.00 / 15.20 11.32 / 10.98 14.50 / 13.57 16.05 / 15.11Power input Heating Nom. kW 2.55 / 3.17 3.26 / 4.04 3.92 / 4.75 2.63 / 3.24 3.42 / 4.21 3.82 / 4.69COP 4.39 / 3.25 4.29 / 3.24 4.08 / 3.20 4.30 / 3.39 4.24 / 3.22 4.20 / 3.22Domestic hot water heating

General Declared load profile -Average climate ηwh (water heating efficiency) % -

Water heating energy efficiency class -Space heating Average climate water

outlet 55°CGeneral ηs (Seasonal space heating efficiency) % 114 113 115 117 116 118

SCOP 2.93 2.91 2.94 3.00 2.98 3.03Seasonal space heating eff. class A+

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % 118 130 127 123 118SCOP 3.02 3.32 3.25 3.24 3.14 3.10Seasonal space heating eff. class A A+ A

Indoor Unit EHBH 11CB3V 11CB9W 16CB3V 16CB9W 16CB3V 16CB9W 11CB3V 11CB9W 16CB3V 16CB9W 16CB3V 16CB9WCasing Colour White

Material Precoated sheet metalDimensions Unit HeightxWidthxDepth mm 890x480x344Weight Unit kg 43 44 45 44 45 43 44 45 44 45Operation range Heating Water side Min.~Max. °C 15~55

Domestic hot water Water side Min.~Max. °C 25~80Refrigerant Charge TCO₂eq -

GWP -Sound power level Nom. dBA 41 44 41 44Sound pressure level Nom. dBA 27 30 27 30

Outdoor Unit ERHQ 011BV3 014BV3 016BV3 011BW1 014BW1 016BW1Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320Weight Unit kg 102 108Compressor Quantity 1

Type Hermetically sealed scroll compressorOperation range Cooling Min.~Max. °CDB 10.0~46.0

Domestic hot water Min.~Max. °CDB -20~35Refrigerant Type R-410A

Charge kg 2.7 3.0TCO₂eq 5.6 6.3

GWP 2,087.5Control Expansion valve (electronic type)

Sound power level Heating Nom. dBA 64 66 64 66Cooling Nom. dBA 64 66 69 64 66 69

Sound pressure level

Heating Nom. dBA 49 51 53 51 52Cooling Nom. dBA 50 52 54 50 52 54

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommended fuses A 32 20

Efficiency data EHBX + ERLQ04CB3V +

004CV308CB3V/9W +

006CV308CB3V/9W +

008CV311CB3V/9W +

011CV316CB3V /9W+

014CV316CB3V/9W +

016CV311CB3V/9W +

011CW116CB3V/9W +

014CW116CB3V/9W + 016CW1

Heating capacity Nom. kW 4.40 / 4.03 6.00 / 5.67 7.40 / 6.89 11.20 / 11.00 14.50 / 13.60 16.00 / 15.20 11.20 / 11.00 14.50 / 13.60 16.00 / 15.20Cooling capacity Nom. kW 4.1 / 4.2 5.9 / 4.8 6.2 / 5.4 12.1 / 11.7 12.7 / 12.6 13.8 / 13.1 12.1 / 11.7 12.7 / 12.6 13.8 / 13.1Power input Heating Nom. kW 0.87 / 1.13 1.27 / 1.59 1.66 / 2.01 2.43 / 3.10 3.37 / 4.10 3.76 / 4.66 2.43 / 3.10 3.37 / 4.10 3.76 / 4.66

Cooling Nom. kW 0.90 / 1.80 1.51 / 2.07 1.64 / 2.34 3.05 / 4.31 3.21 / 5.08 3.74 / 5.73 3.05 / 4.31 3.21 / 5.08 3.74 / 5.73COP 5.04 / 3.58 4.74 / 3.56 4.45 / 3.42 4.60 / 2.75 / 3.55 / 2.10 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09 4.60 / 2.75 / 3.55 / 2.10 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09EER 4.55 / 2.32 3.89 / 2.34 3.79 / 2.29 3.98 / 2.72 3.96 / 2.47 3.69 / 2.29 3.98 / 2.72 3.96 / 2.47 3.69 / 2.29Domestic hot water heating

General Declared load profile - LAverage climate ηwh (water heating efficiency) % -

Water heating energy efficiency class -Space heating Average climate water

outlet 55°CGeneral ηs (Seasonal space heating efficiency) % 125 124 126 124 120 122 124 120 122

SCOP 3.20 3.17 3.23 3.18 3.07 3.13 3.18 3.07 3.13Seasonal space heating eff. class A++ A+ A++ A+

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % 178 168 171 155 150 155 150SCOP 4.52 4.27 4.34 3.95 3.83 3.84 3.95 3.83 3.84Seasonal space heating eff. class A+++ A++

Indoor Unit EHBX 04CB3V 08CB3V/9W 08CB3V/9W 11CB3V/9W 16CB3V/9W 16CB3V/9W 11CB3V/9W 16CB3V/9W 16CB3V/9WCasing Colour White

Material Precoated sheet metalDimensions Unit HeightxWidthxDepth mm 890x480x344Weight Unit kg 42 44 45 44 45 43 45 44 46 44 46 43 45 44 46 44 46Operation range Heating Water side Min.~Max. °C 15~55 15~55

Cooling Water side Min.~Max. °C 5~22 5~22Domestic hot water Water side Min.~Max. °C 25~80 25~80

Refrigerant Charge TCO₂eq -GWP -

Sound power level Nom. dBA 40 41 44 41 44Sound pressure level Nom. dBA 26 27 30 27 30

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113 114Compressor Quantity 1

Type Hermetically sealed swing compressor Hermetically sealed scroll compressorOperation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0

Domestic hot water Min.~Max. °CDB -25~35 -20~35Refrigerant Type R-410A

Charge kg 1.5 1.6 3.4TCO₂eq 3.1 3.3 7.1

GWP 2,087.5Control Expansion valve (electronic type)

Sound power level Heating Nom. dBA 61 62 64 66 64 66Cooling Nom. dBA 63 64 66 69 64 66 69

Sound pressure level Heating Nom. dBA 48 49 51 52 51 52Cooling Nom. dBA 48 49 50 50 52 54 50 52 54

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommended fuses A 16 20 40 20

EHBX-CB + ERLQ-CV3/ERLQ-CW1

Specifications

59

Efficiency data EHBX + ERHQ11CB3V +

011BV311CB9W +

011BV316CB3V +

014BV316CB9W +

014BV316CB3V +

016BV316CB9W +

016BV311CB3V + 011BW1

11CB9W + 011BW1

16CB3V + 014BW1

16CB9W + 014BW1

16CB3V + 016BW1

16CB9W + 016BW1

Heating capacity Nom. kW 11.20 (1 / 10.30 (2 14.00 (1 / 13.10 (2 16.00 (1 / 15.20 (2 11.32 (1 / 10.98 (2 14.50 (1 / 13.57 (2 16.05 (1 / 15.11 (2Cooling capacity Nom. kW 13.9 (1 / 10.0 (2 17.3 (1 / 12.5 (2 17.8 (1 / 13.1 (2 15.1 (1 / 11.7 (2 16.1 (1 / 12.6 (2 16.8 (1 / 13.1 (2Power input Heating Nom. kW 2.55 (1 / 3.17 (2 3.26 (1 / 4.04 (2 3.92 (1 / 4.75 (2 2.63 (1 / 3.24 (2 3.42 (1 / 4.21 (2 3.82 (1 / 4.69 (2

Cooling Nom. kW 3.86 (1 / 3.69 (2 5.86 (1 / 5.69 (2 6.87 (1 / 5.95 (2 4.53 (1 / 4.31 (2 5.43 (1 / 5.08 (2 6.16 (1 / 5.73 (2COP 4.39 (1 / 3.25 (2 4.29 (1 / 3.24 (2 4.08 (1 / 3.20 (2 4.30 (1 / 3.39 (2 4.24 (1 / 3.22 (2 4.20 (1 / 3.22 (2EER 3.60 (1 / 2.71 (2 2.95 (1 / 2.32 (2 2.59 (1 / 2.20 (2 3.32 (1 / 2.72 (2 2.96 (1 / 2.47 (2 2.72 (1 / 2.29 (2Domestic hot water heating

General Declared load profile -Average climate ηwh (water heating efficiency) % -

Water heating energy efficiency class -Space heating Average climate water

outlet 55°CGeneral ηs (Seasonal space heating efficiency) % 114 113 115 117 116 118

SCOP 2.93 2.91 2.94 3.00 2.98 3.03Seasonal space heating eff. class A+

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % 118 130 127 130SCOP 3.02 3.32 3.25 3.24 3.14 3.10Seasonal space heating eff. class A A+

Indoor Unit EHBX 11CB3V 11CB9W 16CB3V 16CB9W 16CB3V 16CB9W 11CB3V 11CB9W 16CB3V 16CB9W 16CB3V 16CB9WCasing Colour White

Material Precoated sheet metalDimensions Unit HeightxWidthxDepth mm 890x480x344Weight Unit kg 43 45 44 46 44 46 43 45 44 46 44 46Operation range Heating Water side Min.~Max. °C 15~55

Cooling Water side Min.~Max. °C 5~22Domestic hot water Water side Min.~Max. °C 25~80

Refrigerant Charge TCO₂eq -GWP -

Sound power level Nom. dBA 41 44 41 44Sound pressure level Nom. dBA 27 30 27 30

Outdoor Unit ERHQ 011BV3 014BV3 016BV3 011BW1 014BW1 016BW1Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320Weight Unit kg 102 108Compressor Quantity 1

Type Hermetically sealed scroll compressorOperation range Cooling Min.~Max. °CDB 10.0~46.0

Domestic hot water Min.~Max. °CDB -20 (2.000~35 (2Refrigerant Type R-410A

Charge kg 2.7 3.0TCO₂eq 5.6 6.3

GWP 2,087.5Control Expansion valve (electronic type)

Sound power level Heating Nom. dBA 64 (3 66 (3 64 (3 66 (3Cooling Nom. dBA 64 (4 66 (4 69 (4 64 (4 66 (4 69 (4

Sound pressure level Heating Nom. dBA 49 (5 51 (5 53 (5 51 (5 52 (5Cooling Nom. dBA 50 (6 52 (6 54 (6 50 (6 52 (6 54 (6

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommended fuses A 32 20

Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

EHBX-CB + ERHQ-BV3/ERHQ-BW1

Specifications

60

Single Unit EDLQ/EBLQ 05CV3 07CV3 05CV3 07CV3Heating capacity Nom. kW 4.40 / 4.03 7.00 / 6.90 4.40 / 4.03 7.00 / 6.90Cooling capacity Nom. kW - 3.9 / 4.2 5.2 / 5.4Power input Cooling Nom. kW - 0.95 / 1.80 1.37 / 2.34

Heating Nom. kW 0.88 / 1.13 1.55 / 2.02 0.88 / 1.13 1.55 / 2.02COP 5.00 / 3.58 4.52 / 3.42 5.00 / 3.58 4.52 / 3.42EER - 4.07 / 2.32 3.80 / 2.29Dimensions Unit Height mm 735

Width mm 1,085Depth mm 350

Weight Unit kg 76 80 76 80Operation range Heating Water side Min.~Max. °C 15~55

Cooling Ambient Min.~Max. °CDB -~- 10~43Water side Min.~Max. °C -~- 5~22

Domestic hot water

Ambient Min.~Max. °CDB -25~35Water side Min.~Max. °C 25~80

Refrigerant Type R-410ACharge kg 1.30 1.45 1.30 1.45

TCO₂eq 2.7 3.0 2.7 3.0Control Expansion valve (electronic type)GWP 2,087.5

Sound power level

Heating Nom. dBA 61 62 61 62Cooling Nom. dBA 63

Sound pressure level

Heating Nom. dBA 48 49 48 49Cooling Nom. dBA 48 50 48 50

Space heating Average climate water outlet 55°C

General ηs (Seasonal space heating efficiency) % 125 126 125 126SCOP 3.20 3.22 3.20 3.22Seasonal space heating eff. class A++

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % 172 163 172 163SCOP 4.39 4.14 4.39 4.14Seasonal space heating eff. class A++

EDLQ-CV3/EBLQ-CV3

4. Monobloc outdoor unit

Single Unit EKCB 07CV3 EK2CB07CV3Dimensions Unit Height mm 360

Width mm 340Depth mm 97

Weight Unit kg 4Operation range Heating Ambient Min.~Max. -

Indoor installation

Ambient Min. °CDB 5Max. °CDB 35

Refrigerant Charge TCO₂eq -Control -GWP -

EKCB-CV3/EK2CB-CV3

Single Unit EKMBUHC3V3 EKMBUHC9W1Dimensions Unit Height mm 560

Width mm 250Depth mm 210

Weight Unit kg 11 13Operation range Heating Ambient Min.~Max. -

Indoor installation

Ambient Min. °CDB 5Max. °CDB 30

Refrigerant Charge TCO₂eq -Control -GWP -

EKMBUHC3V3/EKMBUHC9W1

Specifications

61

Accessory EKHWP 300B 500BCasing Colour Traffic white (RAL9016) / Dark grey (RAL7011)

Material Impact resistant polypropyleneDimensions Unit Width mm 595 790

Depth mm 615 790Weight Unit Empty kg 58 82Tank Water volume l 300 500

Material PolypropylenMaximum water temperature °C 85Insulation Heat loss kWh/24h 1.5 1.7Energy efficiency class BStanding heat loss W 64 72Storage volume l 294 477

Heat exchanger Domestic hot water

Quantity 1Tube material Stainless steel (DIN 1.4404)Face area m² 5.600 5.800Internal coil volume l 27.1 29.0Operating pressure bar 6Average specifc thermal output W/K 2,790 2,825

Charging Quantity 1Tube material Stainless steel (DIN 1.4404)Face area m² 3 4Internal coil volume l 13 19Operating pressure bar 3Average specifc thermal output W/K 1,300 1,800

Auxiliary solar heating

Tube material - Stainless steel (DIN 1.4404)Face area m² - 1Internal coil volume l - 2Operating pressure bar - 3Average specifc thermal output W/K - 280

5. Domestic hot water tanks

EKHWP-B

EKHWP-PB

Accessory EKHWP 300PB 500PBCasing Colour Traffic white (RAL9016) / Dark grey (RAL7011)

Material Impact resistant polypropyleneDimensions Unit Width mm - 790

Depth mm 615 790Weight Unit Empty kg 64 92Tank Water volume l 294 477

Material PolypropylenMaximum water temperature °C 85Insulation Heat loss kWh/24h 1.5 1.7Energy efficiency class BStanding heat loss W 64 72Storage volume l 294 477

Heat exchanger Domestic hot water

Quantity 1Tube material Stainless steel (DIN 1.4404)Face area m² 5.600 5.800Internal coil volume l 27.1 29.0Operating pressure bar 6Average specifc thermal output W/K 2,790 2,825

Charging Quantity 1Tube material Stainless steel (DIN 1.4404)Face area m² 3 4Internal coil volume l 13 19Operating pressure bar 3Average specifc thermal output W/K 1,300 1,800

Auxiliary solar heating

Tube material - Stainless steel (DIN 1.4404)Face area m² - 1Internal coil volume l - 2Operating pressure bar - 3Average specifc thermal output W/K - 280

*Note: blue cells contain preliminary data

Specifications

62

Accessory EKHWE 150A3V3 200A3V3 300A3V3 200A3Z2 300A3Z2Casing Colour RAL9010

Material Epoxy coated steelDimensions Unit Diameter mm 545 660 545 660Weight Unit Empty kg 80 104 140 104 140Tank Water volume l 150 200 300 200 300

Material Enamel coated steel acc. DIN4753TL2Maximum water temperature °C 75Insulation Heat loss kWh/24h 1.7 1.9 2.5 1.9 2.5Energy efficiency class C D C DStanding heat loss W 71 79 104 79 104Storage volume l 150 200 300 200 300

Heat exchanger Quantity 1Booster heater Capacity kW 3Power supply Phase/Frequency/Voltage Hz/V 1~/50/230 2~/50/400

EKHWE-A3V3/EKHWE-A3Z2

Accessory EKHWS 150B3V3 200B3V3 300B3V3 200B3Z2 300B3Z2Casing Colour Neutral white

Material Epoxy-coated mild steelDimensions Unit Width mm 580

Depth mm 580Weight Unit Empty kg 37 45 59 45 59Tank Water volume l 150 200 285 200 285

Material Stainless steel (DIN 1.4521)Maximum water temperature °C 85Insulation Heat loss kWh/24h 155.0 177.0 219.0 177.0 219.0Energy efficiency class CStanding heat loss W 65 74 91 74 91Storage volume l 150 200 285 200 285

Heat exchanger Quantity 1Tube material Duplex steel LDX 2101

Booster heater Capacity kW 3Power supply Phase/Frequency/Voltage Hz/V 1~/50/230 2~/50/400

EKHWS-B3V3/EKHWS-B3Z2

Specifications

63

6. Solar system

EKSH-P/EKSV-P

Accessory EKSV/EKSH EKSH26P EKSV21P EKSV26PMounting Horizontal VerticalDimensions Unit HeightxWidthxDepth mm 2,000x85x1,300 1,006x85x2,000 1,300x85x2,000Weight Unit kg 42 33 42Volume l 21 1.3 1.7Surface Outer m² 2.6 2.01 2.60

Aperture m² 2.360 1.800 2.360Absorber m² 2.35 1.79 2.35

Coating Micro-therm (absorption max. 96%, Emission ca. 5% +/-2%)Absorber Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plateGlazing Single pane safety glass, transmission +/- 92%Allowed roof angle Min.~Max. ° 15~80Operating pressure Max. bar 6Stand still temperature Max. °C 192Thermal performance

Zero loss collector efficiency η0 % -Heat loss coefficient a1 W/m².K 4.250 4.240 4.250Temperature dependence of the heat loss coefficient a2 W/m².K² 0.007 0.006 0.007Thermal capacity kJ/K 6.5 4.9 6.5

Accessory EKSRPS 4Mounting On side of tankDimensions Unit HeightxWidthxDepth mm 815x142x230Weight Unit kg 6Operation range Ambient temperature Min.~Max. °C 5~40Operating pressure Max. bar 0Stand still temperature Max. °C 85Thermal performance

collector efficiency (ηcol) % -Zero loss collector efficiency η0 % -

Control Type Digital temperature difference controller with plain text displayPower consumption W 2

Power supply Phase/Frequency/Voltage Hz/V 1~/50/230Power supply intake Indoor unit

EKSRPS

Accessory EKSRDS2Mounting On wallDimensions Unit HeightxWidthxDepth mm 410x314x154Thermal performance Zero loss collector efficiency η0 % -Control Type Digital temperature difference controller with plain text displayPower supply Frequency/Voltage V 50/230

EKSRDS2

Specifications

64

7. Controls

EKRUCBL/EKRUCBS

EKRTW/EKRTR

Indoor unit EKRUCBL1-7 EKRUCBSControl systems Class of temperature control VI

Contribution to seasonal space heating efficiency % 4.0

Accessory EKRTR1 EKRTWADimensions Unit HeightxWidthxDepth mm 87x125x34

Receiver Height/Width/Depth mm 170/50/28 -Weight Unit g - 215

Thermostat g 210 -Receiver g 125 -

Ambient temperature

Storage Min./Max. °C -20/60Operation Min./Max. °C 0/50

Temperature setting range

Heating Min./Max. °C 4/37Cooling Min./Max. °C 4/37

Clock YesRegulation function Proportional bandPower supply Voltage V - Battery powered 3* AA-LR6 (alkaline)

Thermostat Voltage V Battery powered 3x AA-LRG (alkaline) -Receiver Voltage V 230 -Frequency Hz 50 -Phase 1~ -

Connection Type - WiredThermostat Wireless -Receiver Wired -

Maximum distance to receiver

Indoor m approx. 30m -Outdoor m approx. 100m -

Control systems Class of temperature control IVContribution to seasonal space heating efficiency % 2.0

Specifications

65

Trust DaikinDaikin may not be a household name. After all, we don’t make cars, TVs, fridges or washing machines. But we do make world-class heat pumps. In fact, more than 275,000 Daikin Altherma heat pumps have been fitted across Europe since its initial launch in 2006.Because we focus on doing only what we’re best at: creating the most efficient heating, ventilation and air conditioning solutions, renowned for design excellence, quality and reliability. So you can depend on Daikin for the ultimate in comfort, leaving you free to focus on other essentials.

The present publication is drawn up by way of information only and does not constitute an offer binding upon

Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge.

No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose

of its content and the products and services presented therein. Specifications are subject to change without prior

notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense,

arising from or related to the use and/or interpretation of this publication. All content is copyrighted by

Daikin Europe N.V.

The present publication supersedes ECPEN14-721. Printed on non-chlorinated paper.

Prepared by La Movida, Belgium.

Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor)

Daikin Europe N.V. participates in the Eurovent Certification

programme for Liquid Chilling Packages (LCP), Air handling

units (AHU) and Fan coil units (FCU), Check ongoing validity

of certificate online: www.eurovent-certification.com or using:

www.certiflash.com

ECPEN15 - 724 XXX · 07/15