10
BT-500 Infant Incubator Accurate humidity control Comfortable and soft tilting structure 7” TFT color LCD display Various alarm function (27 events) Low noise hood MASIMO SpO2 and CCD camera Accurate weighing scale (±10g) 7 th Fl., A Bldg., Woolim Lions Valley 5-cha, 302, Galmachi-ro, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Tel : 82-31-750-0340 Fax : 82-31-750-0344 E-mail : [email protected] Http://www.bistos.co.kr Infant Incubator BT-500

Infant Incubator BT-500 - Bio Pro...Category Infant Warmer Temp. Control Mode Prewarm / Baby / Manual Skin Temp. Control 34 - 38 C Measurement 26 - 42 ±0.3 C Heater Type Infrared

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • BT-500 Infant Incubator

    • Accurate humidity control • Comfortable and soft tilting structure • 7” TFT color LCD display • Various alarm function (27 events) • Low noise hood • MASIMO SpO2 and CCD camera • Accurate weighing scale (±10g)

    7th Fl., A Bldg., Woolim Lions Valley 5-cha, 302, Galmachi-ro, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Tel : 82-31-750-0340 Fax : 82-31-750-0344 E-mail : [email protected] Http://www.bistos.co.kr

    Infant Incubator

    BT-500

    mailto:[email protected]://www.bistos.co.kr/

  • BT-500 Infant Incubator

    IV Pole (option) IV Plate (option)

    Weighing Scale (option)

    Water Tank (1L)

    Mattress Tilt

    Basket (option) Lifting Stand (option)

    Main Display

    X-ray Tray

    O2 Control & Monitoring

    Masimo SpO2 & CCD camera

    • Power-on Self-test The incubator performs a self-test each time it is turned on. This process allows the incubator to check various systems for proper operation. When the test is successfully completed, the BT-500 displays the main screen.

    • Configuration Standard Temperature & Humidity servo control, Fixed stand, X-ray tray, Tilting, 2 pcs skin temp. sensor, 4pcs Air Filter Options IV pole, IV plate, Lifting stand, O2 monitoring, O2 servo control, Weighing scale, Basket, Shelf, External monitor with Masimo SpO2 & CCD camera

  • BT-500 Infant Incubator

    • Double Wall The hood is used to protect an infant from the external environment and maintain the internal environment of hood to best condition. BT-500 has double wall structure to minimize heat loss. The analysis result of Air flow and temperature distribution are shown as below figure.

    < Analysis inside incubator Air flow and Temp distribution by Fluid Analysis (Yonsei Univ. Korea) >

    Temp after 10 sec. Temp after 20 sec.

    Temp after 30 sec. Temp after 40 sec.

    X-axis. Y-axis.

    Z-axis. Temp after 20 sec.

    • Air Curtain BT-500 has Air Curtain function to reduce temperature fluctuation in hood when the hood door is opened for treatment of infant.

    • Alarm Function Alarm of BT-500 indicates the condition of failure. According to each alarm condition, alarm messages are displayed and alarm sound is caused and sensor module’s LED blinks. There are 27 kinds of alarms by failure situation. System Alarms Motor failed, Heater system failed, Humidity heater failed, Stuck key, Humidity sensor failure, Air sensor failure, Fan power failure, Air circulation failure, Skin probe fail, Remove skin 2 probe, Sensor module disconnected, Sensor module not in position Temperature Alarms Low air temperature, High air temperature, Low skin temperature, High skin temperature, High skin 1 temperature, High skin 2 temperature, High temperature cutout, Over skin temperature Humidity Alarms Low humidity, Water empty Oxygen Alarms O2 module power failure, O2 module detached, O2 sensor fault, Low oxygen, High oxygen Weighing Scale Alarms Too much weight

  • BT-500 Infant Incubator

    • Quick Guide BT-500 has Help function which provides the simple information about the equipment. The information is as below : - Part of full set BT-500 - Main control panel and main display - How to use and change mode and parameters

    • External Monitor BT-500 uses external 7” color TFT LCD monitor that displays measured values from the control and video of infant inside the hood. Cam mode, Graph mode and Masimo mode are shown as below. Cam Mode (a) Air temperature, skin temperature, humidity, oxygen concentration and weighing scale are displayed on external monitor with real-time video of infant. Graph Mode (b) Air temperature, skin temperature, humidity, oxygen concentration and weighing scale, SpO2 and PR are displayed on external monitor with real-time video of infant. Also, graphs of each parameters are displayed. Masimo Mode (c) Air temperature, skin temperature, humidity, oxygen concentration and weighing scale are basically displayed. SpO2 and PR are mainly displayed.

  • BT-500 Infant Incubator

    * All specifications can be different by country and are subject to change without notice.

    Specifications : BT-500 Infant Incubator Functional Characteristics

    Temperature Control Humidity Control

    Air Control Range Normal : 23.0 ~ 37.0°C Control Range 30 ~ 95%

    Override : 37.1 ~ 39.0°C Measurement Range 15~99% ±5% RH(non-condesing)

    Air Measurement range 20.0 ~ 45.0°C ±0.5°C Control System Steam(Boiling at 100°C)

    Skin Control Range Normal : 35.0 ~ 37.5°C Water Tank 1,000ml (Autoclavable)

    Override : 37.6 ~ 39.0°C Display

    Skin Measurement range 25.0 ~ 45.0°C ±0.3°C Type 7" TFT Color LCD

    Function Hood

    Microprocessor Controlled & Double Safety Feature Mattress tilt up to 12°

    Trend 9~72hours (Weighing Scale 9days) Noise Level < 45dB

    Alarm(Visual & Sound) 27 Events Alarms Air Filter Particle Size 0.3micron

    Warm-up Time Silent Mode : 60min,

  • Neonatal CareSystem

    Infant Incubator

    Infant Warmer

    Phototherapy

  • 02 03 BIO SIGNAL TOTAL SOLUTION

    Environment designed for premature baby Double Wall and air curtain maintain constant temperature control in the hood and help the infant keep their temperature.

    Low operation noise and the part that makes noise is designed to make only minimal noise to ensure quiet environment

    In-built x-ray tray and weighing scale minimize the necessity for premature baby leave the incubator for additional care.

    Tilting of best enable Trendelenburg and reverse- Trendelenburg for faster recovery

    Built-in Masimo Pulse Oximeter provides most accurate measurement for SpO2.

    Water tank can be disinfected by autoclaving.

    O2 Servo control and measurement available

    Trend Display External Monitor*Masimo Pulse oximeter*

    X-ray tray

    Double wall

    Tilt

    Convenience designed for medical staff Lifting stand adjust mattress height to optimized height for each staff

    Large 6 doors on every side of hood enable the premature baby can be accessible in every direction.

    CCD Camera shows the status of infant in additional display even if the incubator is covered. Even the video can be displayed on mobile phone or PC simultaneously by wireless connection.

    Multi language support helps the staff operate the incubator properly with the instruction in their own languages.

    Large size basket and have enough inner space to store all necessaries for infant care.

    Two skin temperature measures both temperature from belly and peripheral.

    Basket* Peripheral temperature

    Lifting Stand*

    *Option

    BT-500 Infant Incubator

  • 04 05 BIO SIGNAL TOTAL SOLUTION

    Servo temperature control (Manual, Baby, Pre-warm mode)

    Swivel head and X-rays tray for other procedure

    Tilting mattress for Trendelenburg treatment

    Easy removable side walls for easy access and cleaning

    APGAR timer for 1, 5, 10 minutes

    LED Examination light for 3 level brightness

    Highly effective blue LED light

    Fan-less design for noiseless treatment

    Intensity control (high & low)

    Extensive long LED life time up to 100,000 hours

    Displays treatment time and total used timeb

    Built-in clamp provides various installation options

    Swivel head

    with Incubatorwith Cart with IV pole

    8 Power LED Mobile design

    Tilting*

    Removable wall

    Adjustable position

    LED examination light

    BT-550 Infant Warmer

    BT-400 Phototherapy

    *Option

  • Technical Specification

    Model BT-500Category Infant Incubator

    Air Temp.Control

    Normal : 23 - 37°C

    Override : 37.1 - 39°C

    Measurement 20 - 45 ±0.5°C

    Skin Temp. Control

    Normal : 35 - 37.5°C

    Override : 37.6 - 39°C

    Measurement 25 - 45 ±0.3°C

    Humidity

    Control 30 - 95%

    Measurement 15 - 99 ±5% RH

    System Steam (Boiling at 100°C)

    Water Tank 1,000ml (Autoclavable)

    Scale *Measurement 0 - 10Kg ±10g

    Trend 216 Hour

    O2 *Control 21 - 65 ±5%

    Measurement 18 - 100 ±5%

    MasimoSpO2 *

    Measurement 1 - 100%

    Accuracy± 3% (70-100%)

    Unspecified (0~69%)

    Pulse Rate Range 25 - 240bpm ±3bpm

    CCD Camera *Resolution 2.5M pixel

    Video Transfer Wi-Fi

    Hood

    Hand Port 6 Door

    Tubing Port 2 x 6 Port

    Structure Double wall

    Air Curtain Support

    Noise < 45dB

    Bed

    Tilt < 12°

    Matress 72 x 39 x 2 cm

    X-ray tray 35 x 40 cm

    Lifting Stand * Height 65 - 85 cm

    IV Plate * Load limit 11 Kg

    IV Pole * Hook 2 Hook

    Basket * Load limit 10 Kg

    Shelf * Load limit 3 Kg

    Air filterParticle 0.3 Micron

    Efficiency 99.8%

    General

    Display 7” TFC Color LCD

    Trend 72 Hour

    Alarm 27 Events (Visual & Sound)

    Warm up < 30 Minute (Fast Mode)

    Self Test Power On

    Multi Language Support

    Quick Guide In-built

    DimensionsStandard (HWD) 1,354 x 1,024 x 690 mm

    With Lifting (H) 1,244 - 1,444 mm

    WeightStandard 99.3 Kg

    Maximum 117.5 Kg

    Warranty Main unit 2 year

    Model BT-550Category Infant Warmer

    Temp. Control Mode Prewarm / Baby / Manual

    Skin Temp. Control 34 - 38 °CMeasurement 26 - 42 ±0.3°C

    Heater

    Type InfraredControl 0 - 100% / 20 LevelPower 600WLife Time 5,000 HourRotation 90°

    APGA TimerSetting 0 - 59 min. 59 sec.Beep 1, 5, 10 min.

    ExaminationPower 40W LED (10W x 4)Control 3 LevelIllumination > 7,000 lx

    Scale * Measurement 0 - 10Kg ±10g

    MasimoSpO2 *

    Measurement 1 - 100%

    Accuracy± 3% (70-100%)

    Unspecified (0~69%)Pulse Rate Range 25 - 240bpm ±3bpm

    BedTilt * < 15°Matress 80 x 49 x 2cmX-ray tray 35 x 40 cm

    Lifting Stand * Height 65 - 85 cmIV Plate * Load limit 11 KgIV Pole * Hook 2 HookBasket * Load limit 10 KgShelf * Load limit 3 KgOxygen Delivery * Regulator, Humidifier, Bracket

    General

    Display 7” TFC Color LCDAlarm 6 Events (Visual & Sound)Self Test Power OnLeveler Bubble type

    DimensionsStandard (HWD) 1,890 x 1,027 x 690 mmWith Lifting (H) 1,780 - 1,980 mm

    WeightStandard 83 KgMaximum 98 Kg

    Warranty Main unit 2 year

    06 07 BIO SIGNAL TOTAL SOLUTION

    Model BT-400Category Phototherapy

    Light Source Blue LEDWavelength Peak Between 450 - 475 nm

    IntensityLow 25 - 35 μW/cm²/nmHigh 35 - 55 μW/cm²/nm

    Intensity Variation (over 6 hrs) ±10%LED Life Time 100,000 HourEffective Surface (at 40cm) Approx. 40 x 20 cmHeat output over 6hours < 10 ℃ than ambientAudible Noise < 30 dB (Fanless)Clamp Max. diameter 3.5cmShade * Covers Incubator and WarmerCart * Height : 74 - 118cm

    GeneralDisplay 2.4” TFT Color LCDTime Display Treatment time, Total used timeTimer 30 min. - 999 hrs.

    Dimensions(HWD)Head 75 x 340 x 210 mmCart 1000 x 430 x 520 mm

    WeightMain unit 3.6 KgMain unit & Cart 13 Kg

    Warranty Main unit 2 year

    * Option

  • Bistos America Inc. (US Branch)22941, Triton Way, Suite #242, Laguna Hills, CA., USA 92653 Tel. +1-949 614 8745Fax. +1-949 614 8745Site. www.bistosamerica.comE-mail. [email protected]

    [email protected]

    www.bistos.co.kr

    CTD-NICU-001 / Rev.01

    Bistos Co., Ltd. (Headquarter) 7th Fl., A Bldg., Woolim Lions Valley 5-cha, 302, Galmachi-ro, Jungwon-gu, Seongnam-si,Gyeonggi-do, KoreaTel. +82 (31) 750 0340Fax. +82 (31) 750 0344

    BIO SIGNAL TOTAL SOLUTION