28
Industrial plugs and sockets International Edition

Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

Industrial plugs and sockets

International Edition

Page 2: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

2

About us

Global focus

Well known internationally and certified.

MENNEKES plugs and sockets

are well known all over the

world - and comply with the

relevant national and

international standards. More

than half of our products are

destined for international

markets. This is why MENNEKES

also has a global presence, with

subsidiaries and agencies in

more than 90 countries. When

plugs and sockets are being

tested by independent testing

authorities, such as the VDE

Testing and Certification

Institute, the test reports are

compiled according to CCA or

CB-II procedures. They then

serve as the basis for approvals

in other countries, such as

those whose national test

marks are shown below. For

plugs and sockets for USA and

Canada please contact us.

Argentina Belgium Denmark GermanyFinland France Great

Britain

Italy

Canada Croatia

Netherlands Norway

Austria

Poland Russia Sweden Switzer-

land

Slovakia Spain South

Africa

Czech

Republic

Hungary

USAPR China

Page 3: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

3

Unmistakable

For more than 75 years the MENNEKES name has been

the byword for unmistakable products in the markets of

the world. Every expert and end user in the electrical industry

knows: Only those products which have the MENNEKES

brand name on, contain MENNEKES quality.

We give you a promise of quality and service. This promise

is one of the main reasons why our family-owned company

has a brand which is irreplaceable. We live our brand and

feel obliged to it. You can rely on MENNEKES. This is and

remains the driving force of our 1.000 employees worldwide.

It is through their daily dedication where they prove their

commitment to the MENNEKES brand, whether it is in

Germany, in Great Britain or in any other part of the world.

Highest quality, reliability, safety, power of innovation,

marketability and sustainability of our action form our brand.

We have a clear identity which makes MENNEKES the ideal

partner for you, our customers and the end user, being a

reliable supplier of an irreplaceable brand.

Kirchhundem headquarters

Only the combination of first-class raw materials and advanced manufacturing processes guarantees a premium product. This is why we use only first-grade granules which are processed by a highly skilled workforce in state-of-the-art production facilities to create certified MENNEKES products.

Page 4: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

63A: SoftCONTACT, 125A: TorsionSpringCONTACT.Other voltages and frequencies available on request. For drawings and dimensions see page 20 - 25.

4

CEE receptacles 16A up to 125A

IP 44

Wall mounted receptacle 1 MB 205DrawingA P 110V 230V 400V16 3 1177 117816 4 1267 126816 5 132 3 1368 136932 4 1371 1372 137332 5 2 IP 44

Wall mounted receptacle 1 MB 209DrawingA P 110V 230V 400V16 3 100 101 10216 4 103 104 10516 5 109 110 111

IP 44

Wall mounted receptacle 1 MB 43DrawingA P 110V 230V 400V16 4 3030 3034 141816 5 3041 3045 141932 3 1420 1421 142232 4 1423 1424 142532 5 1555 1556 1557

IP 44

Wall mounted receptacle 1 MB 213DrawingA P 110V 230V 400V63 3 1136A 1137A 1138A63 4 1139A 1140A 1141A63 5 1143A 1144A 1145A

IP 67

Wall mounted receptacle 1 MB 622DrawingA P 110V 230V 400V16 3 9300 9301 930216 4 9320 9321 932216 5 9340 9341 934232 3 9350 9351 935232 4 9370 9371 937232 5 9380 9381 9382 IP 67

Wall mounted receptacle 1 MB 112DrawingA P 110V 230V 400V63 3 856 128A 129A63 4 130A 131A 132A63 5 134A 135A 136A

IP 67

Wall mounted receptacle 1 MB 162DrawingA P 110V 230V 400V

125 4 137 138 139125 5 141 142 143

with large space for accommodating wiring

IP 67

Wall mounted receptacle 1 MB 163DrawingA P 110V 230V 400V

125 5 2162A

straight

IP 44

Panel mounted receptacle 1 MB 247DrawingA P 110V 230V 400V16 3 1365 1366 136716 4 1388 1389 139016 5 1384 1386 138532 3 1394 1395 139632 4 1397 1398 139932 5 3449 3454 3451

straight

IP 67

Panel mounted receptacle 1 MB 141DrawingA P 110V 230V 400V16 3 217A 218A 219A16 4 220A 221A 222A16 5 226A 227A 228A32 3 229A 230A 231A32 4 232A 233A 234A32 5 238A 239A 240A

angled 20°

IP 44

Panel mounted receptacle 1 MB 260DrawingA P 110V 230V 400V16 3 1462 1463 146416 4 1465 1466 146716 5 1471 1472 147332 3 1491 1492 149332 4 1494 1495 149632 5 1498 1499 1500

angled 20°

IP 67

Panel mounted receptacle 1 MB 251DrawingA P 110V 230V 400V16 3 1474 1475 147616 4 1477 1478 147916 5 1483 1484 148532 3 1501 1502 150332 4 1504 1505 150632 5 1489 1490 1551

straight

IP 44

Panel mounted receptacle 1 MB 211DrawingA P 110V 230V 400V63 3 1260A 1261A 1262A63 4 1246A 1247A 1248A63 5 1250A 1251A 1252A

straight

IP 67

Panel mounted receptacle 1 MB 212/1 MB 258DrawingA P 110V 230V 400V63 3 1263A 1264A 1265A63 4 1122A 1123A 1124A63 5 1126A 1127A 1128A125 3 3380125 4 1455 1456 1457125 5 1459 1460 1461

angled 20°

IP 44

Panel mounted receptacle 1 MB 297DrawingA P 110V 230V 400V63 3 1146A 1147A 1148A63 4 1149A 1150A 1151A63 5 1153A 1154A 1155A

angled 20°

IP 67

Panel mounted receptacle 1 MB 298/1 MB 601DrawingA P 110V 230V 400V63 3 2179A 2180A 2181A63 4 203A 204A 205A63 5 207A 208A 209A125 3 3575125 4 210A 211A 212A125 5 214A 215A 216A

angled 20°, standard flange: 85 x 85 mm, fixing hole spacing: 70 x 70 mm

IP 44

Panel mounted receptacle 1 MB 453DrawingA P 110V 230V 400V16 3 3031 303616 4 307216 5 309332 3 3110 311232 4 313632 5 3153

angled 20°, standard flange: 85 x 85 mm, fixing hole spacing: 70 x 70 mm

IP 67

Panel mounted receptacle 1 MB 452DrawingA P 110V 230V 400V16 3 903 90516 4 108116 5 110332 3 3197 320032 4 325432 5 3524

Page 5: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

Other voltages and frequencies available on request. For drawings and dimensions see page 20 - 25.

5

CEE receptacles 16A up to 32A K screwless connection technique TwinCONTACT

screwless spring terminals

IP 44

Wall mounted receptacle 1 MB 463DrawingA P 110V 230V 400V16 3 1340 134116 4 1342 134316 5 3132 3 1345 134632 4 1347 134832 5 32

screwless spring terminals

IP 44

Wall mounted receptacle 1 MB 209DrawingA P 110V 230V 400V16 3 1719 1720 172116 4 1723 172416 5 1730 3331

screwless spring terminals

IP 44

Wall mounted receptacle 1 MB 43DrawingA P 110V 230V 400V16 4 1750 1751 41816 5 1755 1756 41932 3 1851 420 185232 4 1855 1856 42132 5 1860 1861 422

screwless spring terminals

IP 67

Wall mounted receptacle 1 MB 622DrawingA P 110V 230V 400V16 3 9104 9105 910616 4 9120 9121 912216 5 9140 9141 914232 3 9150 9151 915232 4 9170 9171 917232 5 9180 9181 9182

screwless spring terminals, straight

IP 44

Panel mounted receptacle 1 MB 464DrawingA P 110V 230V 400V16 3 1667 1668 166916 4 1672 1673 167416 5 1678 1679 338532 3 1786 1787 178832 4 1789 1790 179132 5 1795 1796 1797

screwless spring terminals, straight

IP 67

Panel mounted receptacle 1 MB 467DrawingA P 110V 230V 400V16 3 1707 1708 170916 4 1710 1711 171216 5 1716 1717 113132 3 1809 1810 181132 4 1812 1813 181432 5 1818 1819 1820

screwless spring terminals, angled 20°

IP 44

Panel mounted receptacle 1 MB 465DrawingA P 110V 230V 400V16 3 1631 1632 163316 4 1636 1637 163816 5 1642 1643 347332 3 1733 1734 173532 4 1738 1739 174032 5 1744 1745 1746

screwless spring terminals, angled 20°

IP 67

Panel mounted receptacle 1 MB 466DrawingA P 110V 230V 400V16 3 1700 1701 170216 4 1703 170416 5 348532 3 1801 1802 180332 4 1804 180532 5 1808

screwless spring terminals, central fixing, 61 mm Ø mounting hole

IP 44

Panel mounted receptacle RAPIDO® 1 MB 468 DrawingA P 110V 230V 400V16 3 1132 997

screwless spring terminals, central fixing, 70 mm Ø mounting hole

IP 44

Panel mounted receptacle RAPIDO® 1 MB 468DrawingA P 110V 230V 400V16 4 1133 99816 5 90732 3 1135 98732 4 1166 98832 5 989

TwinCONTACTScrewless connection technique

without screws, double terminal with split spring for through-wiring.

RAPIDO®

RAPIDO® receptacles are available with screw terminals or screwless with TwinCONTACT.16A, 3p: for mounting holes 61 mm diam. and wall thickness from 2 up to 5 mm.16A, 4p + 5p and 32A: for mounting holes 70 mm diam. and wall thickness from 2 up to 9 mm.

Page 6: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

Other voltages and frequencies available on request. For drawings and dimensions see page 20 - 25.

6

CEE plugs and inlets 16A up to 125A

single part body, screw terminals

IP 44

Plug AM-TOP®

A P 110V 230V 400V16 3 247 248 24916 4 250 251 25216 5 256 257 332 3 259 260 26132 4 262 263 26432 5 268 269 4

split body, screw terminals

IP 44

Plug ProTOPA P 110V 230V 400V16 3 147A 148A 149A16 4 151A 152A16 5 13A32 3 159 16032 4 163 16432 5 14A

screwless with insulation displacing technique

IP 44

Plug StarTOP® with SafeCONTACTA P 110V 230V 400V16 3 947 94816 4 951 95216 5 3332 3 711 71232 4 717 71932 5 34

with rubberised grip area, for toughest conditions

IP 44

Plug PowerTOP® XtraA P 110V 230V 400V63 3 13101 1310263 4 13105 1310663 5 13111 13112

single part body, screw terminals

IP 67

Plug AM-TOP®

A P 110V 230V 400V16 3 277 278 27916 4 280 281 28216 5 286 287 28832 3 289 290 29132 4 292 293 29432 5 298 299 300

with external strain relief

IP 67

Plug PowerTOP®

A P 110V 230V 400V16 3 3794 3796 379916 4 3807 3811 380916 5 3819 3823 382132 3 3829 3830 383232 4 3839 3844 384132 5 3851 3855 3853

with rubberised grip area, for toughest conditions

IP 67

Plug PowerTOP® XtraA P 110V 230V 400V63 3 13201 13202 1320363 4 13204 13205 1320663 5 13210 13211 13212125 3 13215 13216125 4 13217 13218 13219125 5 13223 13224 13225

* 16A, 5p, 230V and 400V: VarioTOP

IP 44

Angled plugA P 110V 230V 400V16 3 1410 141116 4 891 31516 5 3981* 3980*32 3 3312 330632 4 3646 398732 5 3424 3266

central fixing, 61 mm Ø mounting hole

IP 44

Panel mounted inlet RAPIDO® 2 MB 215 DrawingA P 110V 230V 400V16 3 919 92416 4 93116 5 949

central fixing, 70 mm Ø mounting hole

IP 44

Panel mounted inlet RAPIDO® 2 MB 215DrawingA P 110V 230V 400V16 4 932 93316 5 97232 3 935 93832 4 939 94232 5 945

IP 44

Wall mounted inlet 2 MB 221DrawingA P 110V 230V 400V16 3 843 84416 4 80016 5 80132 3 80232 4 80332 5 804 IP 44

Wall mounted inlet 2 MB 32DrawingA P 110V 230V 400V16 3 331 332 33316 4 334 335 33616 5 340 341 34232 3 343 344 34532 4 346 347 34832 5 352 353 354

with hinged lid

IP 44

Panel mounted inlet 2 MB 43DrawingA P 110V 230V 400V16 4 392 393 39416 5 398 399 40032 3 401 402 40332 4 404 405 40632 5 410 411 412

IP 67

Wall mounted inlet 2 MB 36DrawingA P 110V 230V 400V63 3 1216 1107 121763 4 355 356 35763 5 359 360 361

125 4 362 363 364125 5 366 367 368

IP 44

Panel mounted inlet 2 MB 173/2DrawingA P 110V 230V 400V16 3 810 81216 4 837 81316 5 81532 3 816 81732 4 838 81932 5 821 IP 44

Panel mounted inlet 2 MB 155DrawingA P 110V 230V 400V63 3 822 198163 4 1984 198263 5 1688

IP 67

Panel mounted inlet 2 MB 187/2DrawingA P 110V 230V 400V16 3 825 82616 4 839 82716 5 82932 3 830 83132 4 840 83232 5 834 IP 67

Panel mounted inlet 2 MB 166DrawingA P 110V 230V 400V63 3 835 83663 4 3704 365663 5 3658

125 3 3665125 4 3413 3583125 5 1983

different drawing dimensions for 16A, 3p and 4p

Page 7: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

63A: SoftCONTACT, 125A: TorsionSpringCONTACT.Other voltages and frequencies available on request.

7

CEE connectors 16A up to 125A

single part body, screw terminals

IP 44

Connector AM-TOP®

A P 110V 230V 400V16 3 509 510 51116 4 512 513 51416 5 518 519 532 3 521 522 52332 4 524 525 52632 5 530 531 6

split body, screw terminals

IP 44

Connector ProTOPA P 110V 230V 400V16 3 179A 180A 181A16 4 193A 194A16 5 15A32 3 121 12232 4 125 12632 5 16A

screwless with insulation displacing technique

IP 44

Connector StarTOP® with SafeCONTACTA P 110V 230V 400V16 3 979 98016 4 993 99416 5 3532 3 725 73132 4 761 76332 5 36

with rubberised grip area, for toughest conditions

IP 44

Connector PowerTOP® XtraA P 110V 230V 400V63 3 14101 1410263 4 14105 1410663 5 14111 14112

single part body, screw terminals

IP 67

Connector AM-TOP®

A P 110V 230V 400V16 3 539 540 54116 4 542 543 54416 5 548 549 55032 3 551 552 55332 4 554 555 55632 5 560 561 562

with external strain relief

IP 67

Connector PowerTOP®

A P 110V 230V 400V16 3 3859 3860 386216 4 3869 3873 387116 5 3879 3883 388132 3 3887 3888 389132 4 3896 3899 389732 5 3905 3909 3907

with rubberised grip area, for toughest conditions

IP 67

Connector PowerTOP® XtraA P 110V 230V 400V63 3 14201 14202 1420363 4 14204 14205 1420663 5 14210 14211 14212125 3 14215 14216125 4 14217 14218 14219125 5 14223 14224 14225 IP 44

Angled connectorA P 110V 230V 400V16 3 1438

PowerTOP® Xtra

StarTOP®

PowerTOP® Xtra is rubberised for the best grip. Improved impact resistance even under humid conditions. Highly heat resistant contact carrier, frame terminals, cable gland and sealing, strain relief and protection against kinking. Enclosure with thread lock, two safety slides and plugs with nickel plated contacts. Connectors 63A with SoftCONTACT and 125A with TorsionSpringCONTACT.

SoftCONTACT

TorsionSpringCONTACT

StarTOP® with SafeCONTACT, screwless insulation displacing technique, cable gland with sealing, strain relief, pro tection against kinking, 2-part enclosure with thread lock and safety slide.

Page 8: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

63A: SoftCONTACT, 125A: TorsionSpringCONTACT. Receptacles can be padlocked.Other voltages and frequencies available on request. For drawings and dimensions see page 20 - 25.

CEE receptacles switched 16A up to 125A K with mechanical DUO-interlock

IP 44

Wall mounted receptacle 1 MB 174DrawingA P 110V 230V 400V16 3 7010A 7002A16 4 5457A 5099A 5100A16 5 5459A 5102A 5103A32 3 5743A 5696A32 4 5460A 5104A 5105A32 5 5462A 5107A 5108A IP 67

Wall mounted receptacle 1 MB 207DrawingA P 110V 230V 400V16 3 7011A 7012A16 4 5599A 5600A16 5 5602A 5603A32 3 5924A 5793A32 4 5604A 5605A32 5 5607A 5608A

IP 44

Wall mounted receptacle 1 MB 234DrawingA P 110V 230V 400V63 3 6569 657163 4 5955A 5956A63 5 5959A

IP 67

Wall mounted receptacle 63A: 1 MB 180 / 125A: 1 MB 177DrawingA P 110V 230V 400V63 3 5925A 5911A63 4 5109A 5110A63 5 5112A 5113A

125 3 7060 7000125 4 5887A 5691A125 5 5888A 5692A

IP 44

Wall mounted receptacle 1 MB 550DrawingA P 110V 230V 400V16 3 7602 760316 4 7604 760516 5 760732 3 7611 761232 4 7613 761432 5 7616 IP 67

Wall mounted receptacle 1 MB 551DrawingA P 110V 230V 400V16 3 7620 762116 4 7623 762416 5 762632 3 7628 762932 4 7633 763432 5 7636

IP 44

Panel mounted receptacle 5 MB 59DrawingA P 110V 230V 400V16 3 7502 750316 4 7504 750516 5 750732 3 7511 751232 4 7513 751432 5 7516 IP 67

Panel mounted receptacle 5 MB 57DrawingA P 110V 230V 400V16 3 7520 752116 4 7523 752416 5 752632 3 7530 753132 4 7533 753432 5 7536

fused, DIN-rail

IP 44

Wall mounted receptacle 1 MB 208DrawingA P 110V 230V 400V16 3 721316 4 5610A16 5 5613A32 4 5615A32 5 5618A63 4 6059A63 5 6062A

fused, DIN-rail

IP 67

Wall mounted receptacle 1 MB 181DrawingA P 110V 230V 400V16 3 705016 4 5630A16 5 5633A32 4 5635A32 5 5638A63 4 5640A63 5 5643A

fused, MCB

IP 44

Wall mounted receptacle 1 MB 208DrawingA P 110V 230V 400V16 3 721616 4 721716 5 721832 4 721932 5 722063 4 722163 5 7222

fused, MCB

IP 67

Wall mounted receptacle 1 MB 181DrawingA P 110V 230V 400V16 3 723816 4 723916 5 724032 4 724132 5 724263 4 724363 5 7244

Mechanical DUO interlockAfter insertion and switching on, the plug is interlocked in the ON-position.After switching off and withdrawing, the switch is locked in the OFF-position.

8

Page 9: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

Other voltages and frequencies available on request. For drawings and dimensions see page 20 - 25.

9

CEE phase inverter plugs and inlets, plugs and sockets for low voltage

single part body, screw terminals

IP 44

Phase inverter plug AM-TOP®

A P 110V 230V 400V16 4 338 33916 5 318 31932 4 396 39732 5 321 322

single part body, screw terminals

IP 67

Phase inverter plug AM-TOP®

A P 110V 230V 400V16 4 3338 333916 5 32532 4 3340 334132 5 327 328

split body, screw terminals

IP 44

Phase inverter plug ProTOPA P 110V 230V 400V16 5 3319A32 5 3322

IP 44

Phase inverter VarioTOPA P 110V 230V 400V16 5 859

IP 44

Wall mounted phase inverter inlet 2 MB 221DrawingA P 110V 230V 400V16 5 351732 5 3523

IP 44

Wall mounted phase inverter inlet 2 MB 32DrawingA P 110V 230V 400V16 4 3342 334316 5 251132 4 3345 334632 5 3347 2478

IP 44

Panel mounted phase inverter inlet 2 MB 43DrawingA P 110V 230V 400V16 4 3348 335016 5 2097032 4 3355 335632 5 3717 21241

IP 44

Panel mounted phase inverter inlet 2 MB 68/853DrawingA P 110V 230V 400V16 5 854

IP 44

Wall mounted receptacle 1 MB 294Drawing

A P 20 - 25V50 a. 60 Hz

40 - 50V50 a. 60 Hz

20 - 25V 40 - 50V100-200 Hz

16 2 1825 183116 3 1832 1837 183532 2 1838 184432 3 1845 1850 1848 IP 44

Wall mounted receptacle 1 MB 137Drawing

A P 20 - 25V50 a. 60 Hz

40 - 50V50 a. 60 Hz

20 - 25V 40 - 50V100-200 Hz

16 2 577 57816 3 584 585 58632 2 590 59132 3 597 598 599

IP 44

Panel mounted receptacle 1 MB 136Drawing

A P 20 - 25V50 a. 60 Hz

40 - 50V50 a. 60 Hz

20 - 25V 40 - 50V100-200 Hz

16 2 603 60416 3 610 611 61232 2 616 61732 3 623 624 625 IP 44

Panel mounted receptacle 1 MB 231Drawing

A P 20 - 25V50 a. 60 Hz

40 - 50V50 a. 60 Hz

20 - 25V 40 - 50V100-200 Hz

16 2 1270 285516 3 2845 1272 286032 2 1271 286432 3 2870 1273 2852

IP 44

Plug

A P 20 - 25V50 a. 60 Hz

40 - 50V50 a. 60 Hz

20 - 25V 40 - 50V100-200 Hz

16 2 629A 630A16 3 636A 637A 638A32 2 642A 643A32 3 649A 650A 651A IP 44

Wall mounted inlet 2 MB 160Drawing

A P 20 - 25V50 a. 60 Hz

40 - 50V50 a. 60 Hz

20 - 25V 40 - 50V100-200 Hz

16 2 1955 196116 3 1962 1967 196532 2 1968 197432 3 1975 1980 1978

IP 44

Connector

A P 20 - 25V50 a. 60 Hz

40 - 50V50 a. 60 Hz

20 - 25V 40 - 50V100-200 Hz

16 2 681A 682A16 3 688A 689A 690A32 2 694A 695A32 3 701A 702A 703A

Page 10: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

Other voltages and frequencies available on request. For drawings and dimensions see page 20 - 25.

10

CEE plugs and sockets 7 pole

IP 44

Wall mounted receptacle 1 MB 257DrawingA P 230V 400V 500V16 7 733 734 103532 7 735 736 1040

IP 67

Wall mounted receptacle 1 MB 622DrawingA P 230V 400V 500V16 7 9530 9531 953232 7 9590 9591 9592

angled 20°

IP 44

Panel mounted receptacle 1 MB 260 DrawingA P 230V 400V 500V16 7 737 738 104532 7 739 740 1050

angled 20°

IP 67

Panel mounted receptacle 1 MB 251 DrawingA P 230V 400V 500V16 7 2883 2459 229632 7 2317 2212

single part body, screw terminals

IP 44

Plug AM-TOP®

A P 230V 400V 500V16 7 741 742 105532 7 743 744 1060

single part body, screw terminals

IP 67

Plug AM-TOP®

A P 230V 400V 500V16 7 3776 3777 391332 7 2405 2324 2213

IP 44

Wall mounted inlet 2 MB 147DrawingA P 230V 400V 500V16 7 216632 7 2167

IP 44

Panel mounted inlet 2 MB 71DrawingA P 230V 400V 500V16 7 749 750 107532 7 751 752 1080

single part body, screw terminals

IP 44

Connector AM-TOP®

A P 230V 400V 500V16 7 745 746 106532 7 747 748 1070

single part body, screw terminals

IP 67

Connector AM-TOP®

A P 230V 400V 500V16 7 3783 3916 378432 7 2406 2255 2460

with mechanical DUO-interlock, 3 pole switch, can be padlocked

IP 44

Wall mounted receptacle 1 MB 383DrawingA P 230V 400V 500V16 7 553632 7 7061

with mechanical DUO-interlock, 3 pole switch, can be padlocked

IP 67

Wall mounted receptacle 1 MB 382DrawingA P 230V 400V 500V16 7 578532 7 6106

These plugs and sockets provide solutions where there are multifunctional requirements in industry, farming and commerce.

This number of poles provides solutions in the following fields:

K Star-delta start-up K Closed loop control K Open loop control K Monitoring K Detection and alarms K Clearing alarms K Electrical interlocking

Plugs and sockets 7 pole for multifunctional applications

Page 11: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

Other voltages and frequencies available on request. For drawings and dimensions see page 20 - 25.

11

CEE receptacles Cepex

grey

IP 44

Cepex wall mounted receptacle 1 MB 312DrawingA P 110V 230V 400V16 3 4101 410216 4 4254 410316 5 410532 3 4106 410732 4 410832 5 4110

SCHUKO® 4970

pearl white

IP 44

Cepex panel mounted receptacle 1 MB 315DrawingA P 110V 230V 400V16 3 4111 411216 4 4233 411316 5 411532 3 4116 411732 4 411832 5 4120

SCHUKO® 4971

grey, with labelling field

IP 44

Cepex wall mounted receptacle 1 MB 317DrawingA P 110V 230V 400V16 3 413216 4 413316 5 413532 3 413732 4 413832 5 4140

SCHUKO® 4973

pearl white, with labelling field

IP 44

Cepex panel mounted receptacle 1 MB 318DrawingA P 110V 230V 400V16 3 4141 414216 4 414316 5 414532 3 4146 414732 4 414832 5 4150

SCHUKO® 4974

grey, with labelling field and lockable cover

IP 44

Cepex wall mounted receptacle 1 MB 313DrawingA P 110V 230V 400V16 3 416216 4 416316 5 416532 3 416732 4 416832 5 4170

SCHUKO® 4976

pearl white, with labelling field and lockable cover

IP 44

Cepex panel mounted receptacle 1 MB 320DrawingA P 110V 230V 400V16 3 4171 417216 4 417316 5 417532 3 417732 4 417832 5 4180

SCHUKO® 4977

alpine white

IP 44

Cepex panel mounted receptacle 1 MB 315DrawingA P 110V 230V 400V16 5 426232 5 4263

SCHUKO® 4979

alpine white, with labelling field

IP 44

Cepex panel mounted receptacle 1 MB 318DrawingA P 110V 230V 400V16 3 424716 4 427316 5 423732 3 427432 4 427532 5 4238

SCHUKO® 4980

pearl white

IP 44

Cepex flush mounted receptacle 1 MB 336DrawingA P 110V 230V 400V16 3 412216 5 412532 3 412732 5 4130

SCHUKO® 4972

for Cepex CEE receptacles 16A and 32A and Cepex SCHUKO® receptacles

Flush mounted installation box

41404

Some versions of Cepex panel mounted receptacles are shown on the left. Further versions you can create using Cepex panel mounted receptacles, shown above, in combination with the installation box 41404.

Cepex SCHUKO® panel mounted receptacle with labelling field 4145

+flush mounted installation box 41404

= flush mounted receptacle

Cepex modular system

= Resistant to ball rebound.All Cepex receptacles with neutral covers meet DIN 18032 standards for ball rebound and are suitable for use in sports facilities and comparable environments.

Perfect in every detail - one fits anotherAnything goes. Covers, current rating and colours may be optionally combined: neutral cover, with labelling field, with labelling field and lock, 3 pole, 5 pole and SCHUKO®.

Page 12: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

Plugs and sockets are available in seawater resistant design on request.SCHUKO® and French/Belgian standard 16A, 230V, 2p+E. British standard 13A, 230V, 2p+E.Other voltages and frequencies available on request. For drawings and dimensions see page 20 - 25.

Plugs and sockets 200A - 400A, SCHUKO® and grounding-type receptacles

with cable gland

IP 67

Wall mounted receptacleA P 400V

200 4 75221200 5 75226

with cable gland

IP 67

Wall mounted receptacleA P 400V

250 4 75021250 5 75111400 4 75026400 5 75116

IP 67

Panel mounted receptacleA P 400V

200 4 75241200 5 75246

IP 67

Panel mounted receptacleA P 400V

250 4 75041250 5 75131400 4 75046400 5 75136

switched and interlocked

IP 55

Wall mounted receptacle 1 MB 386DrawingA P 400V

200 4 75231200 5 75236

switched and interlocked

IP 55

Wall mounted receptacle 1 MB 403/2DrawingA P 400V

250 4 75031250 5 75121400 4 75036400 5 75126

with cable gland

IP 67

PlugA P 400V

200 4 75201200 5 75206

with cable gland

IP 67

PlugA P 400V

250 4 75001250 5 75091400 4 75006400 5 75096

with cable gland

IP 67

ConnectorA P 400V

200 4 75211200 5 75216

with cable gland

IP 67

ConnectorA P 400V

250 4 75011250 5 75101400 4 75016400 5 75106

with plug-in terminals or screw terminals, without shutter

IP 54

Panel mounted receptacle SCHUKO® 1 MB 410Drawing

Colourplug-in

terminalsscrew

terminals

grey 11010 11030

blue 11011 11031

black 11012 11032

red 11013 11033

with plug-in terminals or screw terminals, with shutter

IP 54

Panel mounted receptacle SCHUKO® 1 MB 410Drawing

Colourplug-in

terminalsscrew

terminals

grey 11060

blue 11061 11081

with plug-in terminals, without shutter

IP 44

Wall mounted receptacle SCHUKO® 1 MB 27/30Drawing

Colourplug-in

terminalsscrew

terminals

grey 10081

blue 10082

black 10083

with plug-in terminals or screw terminals, without shutter

IP 20

Panel mounted receptacle SCHUKO® 1 MB 450Drawing

Colourplug-in

terminalsscrew

terminals

blue 11511 11531

black 11512 11532

British standard, with screw terminals, with shutter and seal

IP 44

Grounding-type panel mounted receptacle 1 MB 584Drawing

Colourplug-in

terminalsscrew

terminals

blue 10718

combined PE- conductor acc. to German and French/Belgian standards, with grommet

IP 44

Plug SCHUKO®

Colourgrey 10749black 10754orange 10837blue 10838red 10839yellow 10840green 10841

with grommet

IP 44

Connector SCHUKO®

Colourgrey 10751black 10755orange 10842blue 10843red 10844yellow 10845green 10846

for portable use, with front gasket, with plug-in terminals or screw terminals, without shutterIP 54

Panel mounted receptacle SCHUKO® 1 MB 5861Drawing

Colourplug-in

terminalsscrew

terminals

grey 11310 11330

blue 11311 11331

black 11312 11332

red 11313 11333

12

Page 13: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

to VDE 0623-2, EN 60309-2. Earthing contact in the 3 o‘clock position. Colour: electric grey and/or colour code.Other voltages and frequencies available on request. For drawings and dimensions see page 20 - 25.

13

Plugs and sockets for refeer containers

IP 67

Wall mounted receptacleA P h 380 - 440V32 4 3 9562

switched, with mechanical DUO interlock, can be padlocked

IP 67

Wall mounted receptacleA P h 380 - 440V32 4 3 5792A

IP 67

Wall mounted receptacleA P h 380 - 440V32 4 3 5946A

IP 67

Panel mounted receptacleA P h 380 - 440V32 4 3 2123A

single part body, screw terminals

IP 567

Plug AM-TOP®

A P h 380 - 440V32 4 3 2175B

earthing contact in the 3 o’clock position, conforming to VDE 0413 part 9

IP 44

Phase sequence test plugA P h 380 - 440V32 4 3 3718

with hinged lid

IP 67

Panel mounted inletA P h 380 - 440V

200 4 3 2692single part body, screw terminals

IP 67

Connector AM-TOP®

A P h 380 - 440V32 4 3 2177A

1 MB 622Drawing 1 MB 207Drawing

1 MB 181Drawing

straight

CEE receptacles 3 CEE 32A, 4p, 380 - 440V, 3h switched, with mechanical DUO interlock

CEE receptacles

Receptacles SCHUKO®

Fusing3 MCB´s 32A, 3p, C 1 earth bolt M 10, V2A

Connection/feeder cablefor 1 cable up to 5 x 25 mm²Enclosure size520 x 225 mm (H x W)Part no.940027 IP 67

From the AMAXX® enclosure product range with 1, 2, 3, 4 or 5 segments, we put together your desired combination.

Multiple adjacent enclosures can also be connected to form a unit The combinations are manufactured with or without switched interlocked DUO receptacles.

In addition, the enclosures can be equipped with monitoring sockets.

Receptacle combinations for containers, made to measure

1 MB 141Drawing

switched, with mechanical DUO interlock, DIN rail, can be padlocked

Page 14: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

14

Success in seriesExtensively configurable receptacle combinations in six different sizes – the AMAXX® range by MENNEKES. With an appealing and unique design in many variations for almost all applications.

J Protection types: IP 44 and IP 67.J Enclosure materials: AMAPLAST and especially chemical resistant AMELAN®.J Colours: bottom part black, top part grey, silver (IP 44), yellow or red.J Equipped with: CEE receptacles from 16A, 3p up to 63A, 5p, grounding-type receptacles in acc. with many national standards, DUO receptacles switched and interlocked from 16A, 3p to 32A, 5p as well as fuse elements.

130 x 225 x 175 mm (H x W x D)

390 x 225 x 175 mm (H x W x D)

520 x 225 x 185 mm (H x W x D)

260 x 225 x 175 mm (H x W x D)

650 x 225 x 185 mm (H x W x D)

650 x 112.5 x 136 mm (H x W x D)

Features and benefits1 Liftable DIN rails

Liftable DIN rails and a large, smooth wiring space significantly ease the insertion as well as connection of large cables.

2 One-man installationShorter installation times with the new, userfriendly external fixing.

3 Hinged coverThe hinged cover which opens to one side, eases connection work.

4 Ready for applicationAll combinations are pre-wired for installation and tested for electric safety and quality.

Generally angled

insertion direction.

Especially fast opening

and closing of the

enclosure due to captive

doublethreaded cover

screws.

Window can be

locked with a padlock,

enclosure can be sealed.

Both hands free because

inspection windows fold

downwards.

4

3

2

1

AMAXX® receptacle combinations

259 x 225 x 276 mm (H x W x D)

Depth dimensions of the AMAXX®-enclosures without fittings.

Page 15: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

15

AMAXX® receptacle combinations

New standard for low voltage switchgear and control gear assemblies - IEC 61439.

The new standard IEC 61439 replaces IEC 60439 and describes the design and test specifications for low-voltage switchgear and control gear assemblies. The new standard has implications for the distribution of electrical energy in industry, domestic electrical installations and on construction sites.

In the future two main standards will be required for each design of a low-voltage switchgear and control gear assembly:

K The basic standard that is referenced as "Part 1" in the specific standards;K The applicable parts 2 to 7 of the switchgear and control gear assembly standard that deals with the particularities of the application.

The demands imposed on receptacle combinations that must be classified as a switchgear and control gear assembly have changed. Structure and manner of verification have been redefined.

K Product safetyIn the future, all low-voltage switchgear and control gear assemblies must be tested is accordance with IEC 61439. The requirement of design verification is new. Design verification replaces the type test. MENNEKES receptacle combinations are subjected to additional standard-compliant routine tests. The outgoing circuits are individually loaded with the respective rated current.

Your advantage: This guarantees an even higher standard of safety.

K Clear documentationMeaningful rating plate – clearly defined mandatory information, such as rated diversity factor RDF (previously: simultaneity factor).

Your advantage: The main technical product informa-tion is visible on the rating plate at a glance.

K Clear specificationsRequests for a custom solution require clearly defined specifications by the user (such as installation site, ambient temperatures, etc.).

Your advantage: You get a need-based solution by MENNEKES tailored to the specific application.

K Distinction: Original manufacturer - manufacturer If a product is modified on site, the company in question is considered to be the manufacturer. In this case a new verification and documentation are required from this company.

Your advantage: For receptacle combinations that are ready for connection, MENNEKES is the original manufacturer and manufacturer and therefore bears the complete product responsibility.

What has changed with the new switchgear standard - IEC 61439 and what are the benefits for the MENNEKES customer?

InA Rated current of the switchgear and control gear assembly

Un Rated voltage

fn Rated frequency

Icc Conditional rated short-circuit current

Example – rating plate

Protection classIP Ingress protection

RDF Rated diversity factor

For further information please visit our website: www.MENNEKES.de

Page 16: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

CEE receptacles 1 CEE 32A, 5p, 400V

CEE receptacles

Receptacles SCHUKO®

2 SCHUKO® 16A, 230VFusing1 MCB 32A, 3p, C2 MCB´s 16A, 1p, C

Connection/feeder cablefor 1 cable up to 5 x 10 mm²Enclosure size260 x 225 mm (H x W)Part no.920011 IP 44

CEE receptacles 1 CEE 32A, 5p, 400V1 CEE 16A, 5p, 400V

CEE receptacles

Receptacles SCHUKO®

3 SCHUKO® 16A, 230VFusing1 MCB 32A, 3p, C1 MCB 16A, 3p, C3 MCB´s 16A, 1p, C

Connection/feeder cablefor 2 cables up to 5 x 25 mm²Enclosure size390 x 225 mm (H x W)Part no.930011 IP 44

CEE receptacles 1 CEE 32A, 5p, 400V1 CEE 16A, 5p, 400V

CEE receptacles

Receptacles SCHUKO®

6 SCHUKO® 16A, 230VFusing1 RCD 63A, 4p, 0.03A1 MCB 32A, 3p, C1 MCB 16A, 3p, C6 MCB´s 16A, 1p, CConnection/feeder cablefor 2 cables up to 5 x 25 mm²Enclosure size650 x 225 mm (H x W)Part no.950004 IP 44

CEE receptacles 1 CEE 16A, 5p, 400V

CEE receptacles

Rec. Danish standard2 x 13A, 2p+E, 230VFusing1 RCD 40A, 4p, 0.03A1 MCB 16A, 3p, C2 MCB´s 13A, 1p, C

Connection/feeder cablefor 1 cable up to 5 x 10 mm²Enclosure size260 x 225 mm (H x W)Part no.920210 IP 44

CEE receptacles 1 CEE 32A, 5p, 400V

CEE receptacles

Rec. French/Belg. standard3 NF 16A, 2p+E, 230VFusing1 RCD 40A, 4p, 0.03A1 MCB 32A, 3p+N, C1 MCB 16A, 1p+N, C1 off button and 1 indicator light

Connection/feeder cablefor 1 cable up to 5 x 25 mm²Enclosure size390 x 225 mm (H x W)Part no.930038 IP 44

CEE receptacles 1 CEE 32A, 5p, 400V2 CEE 16A, 5p, 400V2 type 25: 16A, 5p, 400V

CEE receptacles

Rec. Swiss standard2 x type 23: 16A, 3p, 230VFusing1 RCD 63A, 4p, 0.03A1 MCB 32A, 3p, C2 MCB´s 16A, 3p, C1 MCB 16A, 1p, CConnection/feeder cablefor 2 cables up to 5 x 25 mm2

Enclosure size520 x 225 mm (H x W)Part no.940809 IP 44

CEE receptacles 1 CEE 63A, 5p, 400V1 CEE 32A, 5p, 400V1 CEE 16A, 5p, 400V

CEE receptacles

Rec. French/Belg. standard4 NF 16A, 2p+E, 230VFusing1 RCD 63A, 4p, 0.03A1 MCB 32A, 3p+N, C1 MCB 16A, 3p+N, C4 MCB´s 16A, 1p+N, CConnection/feeder cablefor 2 cables up to 5 x 25 mm2

Enclosure size650 x 225 mm (H x W)Part no.950022 IP 44

Made of AMAPLAST, pre-wired for installation, IP 44.Enclosure front cover electric grey, yellow or silver, hinged to the side, fusing behind a transparent cover.

16

AMAXX® receptacle combinations

CEE receptacles 1 CEE 32A, 5p, 400V1 CEE 16A, 5p, 400V

Data port sockets1 Cepex RJ45, 2 fold Cat.6Receptacles SCHUKO®

3 SCHUKO® 16A, 230VFusing1 RCD 40A, 4p, 0.03A1 MCB 16A, 3p, C3 MCB´s 16A, 1p, C

Connection/feeder cablefor 1 cable up to 5 x 10 mm²Enclosure size259 x 225 mm (H x W)Part no.970005GE IP 44

Page 17: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

CEE receptacles

CEE receptacles

Receptacles SCHUKO®

3 SCHUKO® 16A, 230VFusing

Connection/feeder cable1.5 m H07RN-F3G1.5 with plug SCHUKO® 16A, 230V

Enclosure size130 x 225 mm (H x W)Part no.910031 IP 44

CEE receptacles 1 CEE 32A, 5p, 400V1 CEE 16A, 5p, 400V

CEE receptacles

Rec. British standard3 x 13A, 2p+E, 230 VFusing1 RCD 40A, 4p, 0.03A1 MCB 16A, 3p, C3 MCB´s 13A, 1p, C

Connection/feeder cable2 m supply H07RN-F5G4 with CEE plug 32A, 5p, 400V

Enclosure size390 x 225 mm (H x W)Part no.931237 IP 44

CEE receptacles 1 CEE 16A, 5p, 400V

CEE receptacles

Receptacles SCHUKO®

3 SCHUKO® 16A, 230VFusing1 RCD 40A, 4p, 0.03A1 MCB 16A, 3p, C3 MCB´s 16A, 1p, C

Connection/feeder cablefor 2 cables up to 5 x 25 mm²Enclosure size390 x 225 mm (H x W)Part no.930022 IP 67

CEE receptacles 1 CEE 32A, 5p, 400V2 CEE 16A, 4p, 400V

CEE receptacles 3 CEE 16A, 3p, 230VReceptacles SCHUKO®

Fusing1 MCB 32A, 3p+N, C1 MCB 16A, 3p, C1 MCB 16A, 1p+N, C

Connection/feeder cablefor 2 cables up to 5 x 25 mm²Enclosure size520 x 225 mm (H x W)Part no.940028 IP 67

CEE receptacles 2 CEE 16A, 5p, 400Vswitched, with mechanical DUO interlock

CEE receptacles

Receptacles SCHUKO®

Fusing2 MCB´s 16A, 3p, C

Connection/feeder cablefor 2 cables up to 5 x 25 mm²Enclosure size390 x 225 mm (H x W)Part no.930031 IP 44

CEE receptacles 2 CEE 32A, 5p, 400V switched with mechanical DUO interlock2 CEE 16A, 5p, 400V

CEE receptacles

Receptacles SCHUKO®

Fusing1 RCD 63A, 4p, 0.03A2 MCB´s 32A, 3p, C2 MCB´s 16A, 3p, C

Connection/feeder cablefor 1 cable up to 5 x 16 mm²Enclosure size650 x 225 mm (H x W)Part no.900946 IP 67

CEE receptacles

CEE receptacles 2 CEE 16A, 3p, 230VReceptacles SCHUKO®

Fusing1 RCD 25A, 2p, 0.03A

Connection/feeder cablefor 1 cable up to 3 x 10 mm²Enclosure size260 x 225 mm (H x W)Part no.920821 IP 67

CEE receptacles 1 CEE 16A, 5p, 400V

CEE receptacles

Rec. French/Belg. standard3 NF 16A, 2p+E, 230VFusing1 RCD 40A, 4p, 0.03A

Connection/feeder cablefor 1 cable up to 5 x 10 mm²Enclosure size650 x 113 mm (H x W)Part no.960042 IP 44

Made of AMAPLAST or AMELAN® (resistant to chemicals), pre-wired for installation, IP 44 or IP 67.Enclosure front cover AMAPLAST electric grey RAL 7035 or AMELAN® grey RAL 7000, hinged to the side (except enclosure size 130 x 225 mm and 650 x 112.5 mm), fusing behind a transparent cover.

17

AMAXX® receptacle combinations

Page 18: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

18

Wall mounted, enclosure380 x 230 mm or

380 x 320 mm

Receptacle strip, enclosure445 x 135 mm

Portable, enclosure306 x 230 x 288 mm or

360 x 340 x 330 mm

Portable, with feeder cable, enclosure

306 x 230 x 288 mm or360 x 340 x 330 mm

AirKRAFT® 3KRAFT® DELTA-BOXES DELTA-BOXES for energy, data, for energy, data, with feeder cable. compressed air. compressed air. Also available with feeder cable. Also available with feeder cable. Enclosure Enclosure Enclosure Enclosure 400 x 229 x 220 mm diam. 240-264 x H 152 mm 114 x 160 x 97 mm 114 x 160 x 97 mm (size without receptacles) (size without receptacles) (size without receptacles) (size without receptacles)

With the EverGUM range MENNEKES provide a solid rubber alternative to enclosures in AMAPLAST, AMELAN® and sheet steel. This is an alternative which is suitable for the most diverse environments, especially when there is likely to be exposure to rough handling or aggressive cleaning agents. These products can also be supplied to conform to the standards of other European countries.

For ceilings, walls and floors. Three colours: Signal yellow, red or silver.AirKRAFT®. Up to four receptacles, or data, or light, plus compressed air, plus fusing. Ready for connection or with supply cable and plug. 3KRAFT®. Equipped to suit your requirements: Up to three receptacles, or data, plus compressed air. Ready for connection or with supply cable and plug.

DELTA-BOX - the classic unit.With cable grip. Enclosure and insert from impact and resistant AMAPLAST. Available in IP 44, IP 67 and IP 68.

EverGUM receptacle combinations with solid rubber enclosures

AirKRAFT® and 3KRAFT® DELTA-BOX

Receptacle combinations for versatile use

Page 19: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

19

Safe. Practical. Timelessly elegant.

Rugged. Vandalism-proof. Steel power posts provide a safe means of energy supply, protection against car-crossing. Hot-dip galvanised and powder coated. Available in various sizes.

Power. Compressed air. Water. Outdoors and indoors.The solution: CombiTOWER®. Short routes to your energy source for industry, workshops, assembly shops, loading platforms, etc.

Stainless steel surface and flush mounted receptacle combinations

Power posts CombiTOWER®

K Protection type IP 43 or IP 44 with closed door, even when plugs are inserted. K The cable guard aperture is sufficiently dimensioned for leading through cables. K Safety lock protects against unauthorised access.

Receptacle combinations for versatile use

Page 20: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

1 MB 27/30 1 MB 43

1 MB 112 1 MB 136

1 MB 137 1 MB 141

1 MB 162 1 MB 163

1 MB 174

1 MB 180 1 MB 181

Drawing1 MB 27/30

Dim. in mm

Drawing Amp. 16 321 MB 43 Poles 4 5 3 4 5Dim. in mm a 128 128 128 128 128

b 84 84 84 84 84c 122 124 136 136 138d 11 11 11 11 11e 68 68 68 68 68f 5,3 5,3 5,3 5,3 5,3g. 4 4 4 4 4h 144 145 158 158 160M 25 25 32 32 32M* 2x25 (blind) to be cut out 2x25 (blind) to be cut out

Max. cable diam. (mm) 18 18 18/25 18/25 18/25Terminal for cond. cross 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —10 —10 —10

Drawing Amp. 631 MB 112 Poles 3 4 5Dim. in mm a 170 170 170

b 118 118 118c 175 175 175d 134,5 134,5 134,5e 103 103 103f 6,1 6,1 6,1g. 6 6 6h 219 219 219M 40 40 40M* 2x40 (blind) to be cut out

Max. cable diam. (mm) 27 27 27Terminal for cond. cross 6 6 6section (mm2) min.-max. —25 —25 —25

Drawing Amp. 16 321 MB 136 Poles 2 3 2 3Dim. in mm a 55 55 55 55

b 55 55 55 55c 44 44 44 44d 45 45 45 45e 45 45 45 45f 4,2 4,2 4,2 4,2g. 8 8 8 8g.1 2 2 2 2h 67 67 67 67k 22 22 22 22l 34 34 34 34

Terminal for cond. cross 4 4 4 4section (mm2) min.-max. —10 —10 —10 —10

Drawing Amp. 16 321 MB 137 Poles 2 3 2 3Dim. in mm a 128 128 128 128

b 84 84 84 84c 120 120 120 120d 11 11 11 11e 68 68 68 68f 5,3 5,3 5,3 5,3g. 4 4 4 4h 146 146 146 146M 25 25 32 32M* 2x25 (blind) to be cut out 2x25 (blind) to be cut out

Max. cable diam. (mm) 18 18 25 25Terminal for cond. cross 4 4 4 4section (mm2) min.-max. —2x6 —10 —2x6 —10

Drawing Amp. 16 321 MB 141 Poles 3 4 5 3 4 5Dim. in mm a 75 75 75 85 85 85

b 75 75 75 75 75 75c 60 61 61 70 70 72d 60 60 60 60 60 60e 60 60 60 60 60 60f 5.5 5.5 5.5 5.5 5.5 5.5g. 8 8 8 8 8 8g.1 2 2 2 2 2 2h 83 88 95 99 99 105i 78 85 96 103 103 110k 31 32 32 39 39 39l 43 52 54 58 58 65

Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5section (mm2) min.-max. —4 —4 —4 —10 —10 —10

Drawing Amp. 1251 MB 162 Poles 4 5Dim. in mm a 264 264

b 163 163c 200 200d 240 240e 140 140f 8,1 8,1g. 8 8h 306 306M 50 50M* 2x50 2x50

Max. cable diam. (mm) 38 38Terminal for cond. cross 25 25section (mm2) min.-max. —35 —35

Drawing Amp. 1251 MB 163 Poles 4 5Dim. in mm a 460 460

b 260 260c 234 234d 434 434e 234 234f 11 11g. 9 9h 519 519M 63 63M* 2x63 2x63

Max. cable diam. (mm) 44 44Terminal for cond. cross 25 25section (mm2) min.-max. —70 —70

Drawing Amp. 16 321 MB 174 Poles 3 4 5 3 4 5Dim. in mm a 225 225 225 225 225 225

b 118 118 118 118 118 118c 141 141 141 146 146 146d 208 208 208 208 208 208e 101 101 101 101 101 101f 6,3 6,3 6,3 6,3 6,3 6,3g. 8 8 8 8 8 8h 250 252 254 264 264 264M 1x25 and 1x32 1x25 and 1x32M* 2x25 2x25 2x25 2x25 2x25 2x25

Max. cable diam. (mm) 25 25 25 25 25 25Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —10 —10 —10

Drawing Amp. 631 MB 180 Poles 3 4 5Dim. in mm a 264 264 264

b 163 163 163c 198 198 198d 240 240 240e 140 140 140f 8,1 8,1 8,1g. 8 8 8h 303 303 303M 40 40 40M* 40 40 40

Max. cable diam. (mm) 32 32 32Terminal for cond. cross 6 6 6section (mm2) min.-max. —25 —25 —25

Drawing Amp. 16 321 MB 181 Poles 3 4 5 4 5Dim. in mm a 364 364 364 364 364

b 134 134 134 134 134c 160 162 163 168 168d 347 347 347 347 347e 117 117 117 117 117f 6,3 6,3 6,3 6,3 6,3g. 8 8 8 8 8h 391 395 398 408 411M 32/40 32/40 32/40 32/40 32/40M* 2x32 2x32 2x32 2x32 2x32

Max. cable diam. (mm) 27 27 27 27 27Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —10 —10

The sizes for the entries on the drawings can be different to the real existing entry sizes.Subject to modification and amendments without prior notice. Errors and omissions excepted.

20

1 MB 177

Drawing Amp. 1251 MB 177 Poles 3 4 5Dim. in mm a 460 460 460

b 260 260 260c 283 283 283d 434 434 434e 234 234 234f 11 11 11g. 9 9 9h 519 519 519M 63 63 63M* 2x63 2x63 2x63

Max. cable diam. (mm) 44 44 44Terminal for cond. cross 25 25 25section (mm2) min.-max. —70 —70 —70

Drawings and dimensions

Page 21: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

1 MB 205

Drawing Amp. 16 321 MB 205 Poles 3 4 5 3 4 5Dim. in mm a 91 91 91 102 102 102

b 73 79 87 89 89 94c 86 93 99 108 108 114d 55 55 56,4 62 62 62e 62 68 76 77,5 77,5 84f 5,3 5,3 5,3 5,3 5,3 5,3g. 8 8 9 10 10 10h 132 132 132 153 153 153M 20 25 25 25 25 32

Max. cable diam. (mm) 13 18 18 18 18 25Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —10 —10 —10

1 MB 207

1 MB 208 1 MB 209

1 MB 211 1 MB 212/1 MB 258

1 MB 213 1 MB 231

1 MB 234 1 MB 247

1 MB 251 1 MB 257

Drawing Amp. 16 321 MB 207 Poles 3 4 5 3 4 5Dim. in mm a 225 225 225 225 225 225

b 118 118 118 118 118 118c 144 146 147 152 152 153d 208 208 208 208 208 208e 101 101 101 101 101 101f 6,3 6,3 6,3 6,3 6,3 6,3g. 8 8 8 8 8 8h 252 255 259 268 268 274M 1xM25 and 1xM32 1xM25 and 1xM32M* 2x25 2x25 2x25 2x25 2x25 2x25

Max. cable diam. (mm) 25 25 25 25 25 25Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —10 —10 —10

Drawing Amp. 16 32 631 MB 208 Poles 3 4 5 4 5 4 5Dim. in mm a 364 364 364 364 364 460 460

b 134 134 134 134 134 180 180c 160 162 163 168 168 195 195d 347 347 347 347 347 440 440e 117 117 117 117 117 160 160f 6,3 6,3 6,3 6,3 6,3 8,1 8,1g. 8 8 8 8 8 8 8h 391 395 398 408 411 502 502M 32/40 32/40 32/40 32/40 32/40 40 40M* 2x32 2x32 2x32 2x32 2x32 2x40 2x40

Max. cable diam. (mm) 27 27 27 27 27 27 27Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 6 6section (mm2) min.-max. —4 —4 —4 —10 —10 —25 —25

Drawing Amp. 161 MB 209 Poles 3 4 5Dim. in mm a 87 100 100

b 64 75 75c 99 110 113d 40 – –d1 – 11 11e 50 59 59f 4,5 5 5g. 4 4 4h 115 125 128M 20 20 20M* M20 (blind) to be cut out

Max. cable diam. (mm) 15 15 15Terminal for cond. cross 1,5 1,5 1,5section (mm2) min.-max. —4 —4 —4

Drawing Amp. 631 MB 211 Poles 3 4 5Dim. in mm a 107 107 107

b 100 100 100c 80 80 80d 85 85 85e 77 77 77f 6. 6. 6.g. 12 12 12g.1 2 2 2h 113 113 113k 55 55 55l 88 88 88

Terminal for cond. cross 6 6 6section (mm2) min.-max. —25 —25 —25

Drawing Amp. 63 1251 MB 212/258 Poles 3 4 5 4 5Dim. in mm a 107 107 107 130 130

b 100 100 100 130 130c 81 81 81 119 119d 85 85 85 104 104e 77 77 77 104 104f 6 6 6 6,5 6,5g 12 12 12 18 18g.1 2 2 2 2 2h 117 117 117 129 129i 113 113 113 126 126k 55 55 55 43 43l 88 88 88 95 95

Terminal for cond. cross 6 6 6 25 25section (mm2) min.-max. —25 —25 —25 —70 —70

Drawing Amp. 631 MB 213 Poles 3 4 5Dim. in mm a 170 170 170

b 118 118 118c 164 164 164d 134,5 134,5 134,5e 103 103 103f 6,1 6,1 6,1g. 6 6 6h 216 216 216M 40 40 40M* 2xM40 (blind) to be cut out

Max. cable diam. (mm) 32 32 32Terminal for cond. cross 6 6 6section (mm2) min.-max. —25 —25 —25

Drawing Amp. 16 321 MB 231 Poles 2 3 2 3Dim. in mm a 68 68 68 68

b 62 62 62 62c 42 42 42 42d 53 53 53 53e 47 47 47 47f 4,5 4,5 4,5 4,5g. 8 8 8 8g.1 2 2 2 2h 72 72 72 72k 32 32 32 32l 55 55 55 55

Terminal for cond. cross 4 4 4 4section (mm2) min.-max. —10 —10 —10 —10

Drawing Amp. 631 MB 234 Poles 3 4 5Dim. in mm a 264 264 264

b 163 163 163c 192 192 192d 240 240 240e 140 140 140f 8,1 8,1 8,1g. 8 8 8h 300 300 300M 40 40 40M* 2x40 2x40 2x40

Max. cable diam. (mm) 27 27 27Terminal for cond. cross 6 6 6section (mm2) min.-max. —25 —25 —25

Drawing Amp. 16 321 MB 247 Poles 3 4 5 3 4 5Dim. in mm a 75 75 75 75 75 75

b 75 75 75 75 75 75c 53 53 55 64 64 65d 60 60 60 60 60 60e 60 60 60 60 60 60f 5.5 5.5 5.5 5.5 5.5 5.5g. 8 8 8 8 8 8g.1 2 2 2 2 2 2h 75 80 83 89 89 100h1 6 8 11 11 12k 31 32 32 39 39 39l 43 52 54 58 58 62

Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5section (mm2) min.-max. —4 —4 —4 —10 —10 —10

ang

le

Drawing Amp. 16 321 MB 251 Poles 3 4 5 7 3 4 5 7Dim. in mm a 73,5 100 100 100 100 100 100 100

b 64 92 92 92 92 92 92 92c 52 60 62 62 64 64 66 66d 60 85 85 85 85 85 85 85e 52 77 77 77 77 77 77 77f 5,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5g. 8 8 8 8 8 8 8 8g.1 2 2 2 2 2 2 2 2h 84 100 105 105 109 109 113 113i 78 85 96 96 103 103 110 110k 43 32 32 39 53 53 45 54l 52 55 65 65 67 67 72 72l1 60 63 72 72 82 82 85 85α 20° 20° 20° 20° 20° 20° 20° 20°

Terminal for cond. cross 1,5 1,5 1,5 1,5 2,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —4 —10 —10 —10 —10

The sizes for the entries on the drawings can be different to the real existing entry sizes.Subject to modification and amendments without prior notice. Errors and omissions excepted.

21

Drawing Amp. 16 321 MB 257 Poles 7 7Dim. in mm a 128 128

b 84 84c 124 138d 11 11e 68 68f 5,3 5,3g. 4 4h 145 160M 25 32M* (blind) to be cut out 2x25 (blind) to be cut out 2x25

Max. cable diam. (mm) 18 25Terminal for cond. cross 1,5 2,5section (mm2) min.-max. —4 —10

Drawings and dimensions

Page 22: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

1 MB 260 1 MB 294

1 MB 297 1 MB 298/1 MB 601

1 MB 312 1 MB 313

1 MB 315 1 MB 317

1 MB 318 1 MB 320

1 MB 336

Drawing Amp. 16 321 MB 260 Poles 3 4 5 7 3 4 5 7Dim. in mm a 73.5 100 100 100 100 100 100 100

b 64 92 92 92 92 92 92 92c 50 59 58 58 62 62 61 61d 60 85 85 85 85 85 85 85e 52 77 77 77 77 77 77 77f 5.5 5.5 5.5 5,5 5.5 5.5 5.5 5,5g. 7 8 8 8 8 8 8 8g.1 2 2 2 2 2 2 2 2h 79 100 100 100 103 103 106 106k 44 34 34 40 54 54 49 55l 52 55 65 65 67 67 72 72l1 60 63 72 72 82 82 85 85α 20° 20° 20° 20° 20° 20° 20° 20°

Terminal for cond. cross 1.5 1.5 1.5 1,5 2.5 2.5 2.5 2,5section (mm2) min.-max. —4 —4 —4 —4 —10 —10 —10 —10

angle

Drawing Amp. 631 MB 297 Poles 3 4 5Dim. in mm a 110 110 110

b 106 106 106c 85 85 85d 85 85 85e 77 77 77f 6,2 6,2 6,2g. 12 12 12g.1 2 2 2h 122 122 122k 69 69 69R 46 46 46α 20° 20° 20°

Terminal for cond. cross 6 6 6section (mm2) min.-max. —25 —25 —25

1 MB 298 Amp. 63 1251 MB 601 Poles 3 4 5 3 4 5Dim. in mm a 110 110 110 114 114 114

b 106 106 106 110 110 110c 85 85 85 75 75 75d 85 85 85 90 90 90e 77 77 77 90 90 90f 6,2 6,2 6,2 6,2 6,2 6,2g. 12 12 12 13 13 13g.1 2 2 2 2 2 2h 128 128 128 133 133 133i 113 113 113 126 126 126k 67 67 67 103 103 103l 92 92 92 94 94 94l1 98 98 98 107 107 107˂ 20° 20° 20° 15° 15° 15°

Terminal for cond. cross 6 6 6 25 25 25section (mm2) min.-max. —25 —25 —25 70 70 70

Drawing Amp. 16 321 MB 312 Poles 3 4 5 3 4 5Dim. in mm a 93 93 93 93 93 93

b 90 90 90 90 90 90c 87 87 87 99 99 99d 75 75 75 75 75 75e 73 73 73 73 73 73f 5,5 5,5 5,5 5,5 5,5 5,5g. 4,2 4,2 4,2 4,2 4,2 4,2k 33 33 33 33 33 33y 25,5 25,5 25,5 25,5 25,5 25,5M 25x1,5 25x1,5 25x1,5 25x1,5 25x1,5 25x1,5

Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —6 —6 —6

Drawing Amp. 16 321 MB 313 Poles 3 4 5 3 4 5Dim. in mm a 93 93 93 93 93 93

b 90 90 90 90 90 90c 90 90 90 102 102 102d 75 75 75 75 75 75e 73 73 73 73 73 73f 5,5 5,5 5,5 5,5 5,5 5,5g. 4,2 4,2 4,2 4,2 4,2 4,2k 36 36 36 36 36 36y 25,5 25,5 25,5 25,5 25,5 25,5M 25x1,5 25x1,5 25x1,5 25x1,5 25x1,5 25x1,5

Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —6 —6 —6

Drawing Amp. 16 321 MB 315 Poles 3 4 5 3 4 5Dim. in mm k 32 32 32 48 48 48Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —6 —6 —6

Drawing Amp. 16 321 MB 317 Poles 3 4 5 3 4 5Dim. in mm a 93 93 93 93 93 93

b 90 90 90 90 90 90c 88 88 88 100 100 100d 75 75 75 75 75 75e 73 73 73 73 73 73f 5,5 5,5 5,5 5,5 5,5 5,5g. 4,2 4,2 4,2 4,2 4,2 4,2k 34 34 34 34 34 34y 25,5 25,5 25,5 25,5 25,5 25,5M 25x1,5 25x1,5 25x1,5 25x1,5 25x1,5 25x1,5

Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —6 —6 —6

Drawing Amp. 16 321 MB 318 Poles 3 4 5 3 4 5Dim. in mm k 32 32 32 48 48 48Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —6 —6 —6

Drawing Amp. 16 321 MB 320 Poles 3 4 5 3 4 5Dim. in mm k 32 32 32 48 48 48Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —6 —6 —6

Drawing Amp. 16 321 MB 336 Poles 3 4 5 3 4 5Dim. in mm a 93 93 93 93 93 93

b 90 90 90 90 90 90

c 95 95 95 95 95 95

h 111 111 111 111 111 111

i 124 124 124 124 124 124

k 33 33 33 33 33 33

n 91 91 91 91 91 91

o 95 95 95 95 95 95

Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5

section (mm2) min.-max. —4 —4 —4 —6 —6 —6

The sizes for the entries on the drawings can be different to the real existing entry sizes.Subject to modification and amendments without prior notice. Errors and omissions excepted.

22

1 MB 382

Drawing Amp. 16 321 MB 382 Poles 7 7Dim. in mm a 225 225

b 118 118c 147 153d 208 208e 101 101f 6,3 6,3g. 8 8h 259 274M 1x25 and 1x32 1x25 and 1x32M* 2x25 2x25

Max. cable diam. (mm) 25 25Terminal for cond. cross 1,5 2,5section (mm2) min.-max. —4 —10

Drawing Amp. 16 321 MB 294 Poles 2 3 2 3Dim. in mm a 96 96 96 96

b 73 73 73 73c 90 90 90 90d 53 53 53 53d1 52 52 52 52d2 2 2 2 2e 62 62 62 62f 5,3 5,3 5,3 5,3g 8 8 8 8h 129 129 129 129

Terminal for cond. cross 4 4 4 4section (mm2) min.-max. —10 —10 —10 —10

Drawings and dimensions

Page 23: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

1 MB 383 1 MB 386

1 MB 403/2 1 MB 410

1 MB 422 1 MB 450

1 MB 452 1 MB 453

1 MB 463 1 MB 464

1 MB 465

Drawing Amp. 16 321 MB 383 Poles 7 7Dim. in mm a 225 225

b 118 118c 141 146d 208 208e 101 101f 6,3 6,3g. 8 8h 254 264M 1x32 and 1x25 1x32 and 1x25M* 2x25 2x25

Max. cable diam. (mm) 25 25Terminal for cond. cross 1,5 2,5section (mm2) min.-max. —4 —10

Drawing 1 MB 386

Dim. in mm

Drawing 1 MB 404/2

Dim. in mm

Drawing1 MB 410

Dim. in mm

Installation dimensions in mm

receptacles

Drawing1 MB 422

Dim. in mm

Drawing1 MB 450 Dim. ADrawing in mm

SCHUKO 18,3

French/Belgian standards 15,8Danish standards 15,8

angle

Drawing Amp. 16 321 MB 453 Poles 3 4 5 3 4 5Dim. in mm a 85 85 85 85 85 85

b 85 85 85 85 85 85c 53 57 57 60 60 67d 70 70 70 70 70 70e 70 70 70 70 70 70f 5.5 5.5 5.5 5.5 5.5 5.5g 8 8 8 8 8 8g.1 2 2 2 2 2 2h 89 96 101 103 103 110k 39 34 33 53 53 41

I min. 57 64 70 78 78 78I max. 78 78 78 78 78 78

Terminal for cond. cross 1.5 1.5 1.5 2.5 2.5 2.5section (mm2) min.-max. —4 —4 —4 —10 —10 —10

Drawing Amp. 16 321 MB 463 Poles 3 4 5 3 4 5Dim. in mm a 95 93 92,5 102 102 102

b 73,5 87,5 87,5 94 94 94c 93 107,5 110 115,5 115,5 119,5d 55,5 55,5 55,5 62 62 62e 61 76 76 84 84 84f1 5,3 5,3 5,3 5,1 5,1 5,1f2 5,3 5,3 5,3 5,1 5,1 5,1h 139 139 136,5 160 160 156,5i 19,8 21,5 21,5 26,5 26,5 26,5M M20x M25x M25x M25x M32x M32x

1,5 1,5 1,5 1,5 1,5 1,5Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —6 —6 —6

Drawing Amp. 16 321 MB 464 Poles 3 4 5 3 4 5Dim. in mm a 75 75 75 75 75 75

b 75 75 75 75 75 75c 53 53 54 64 64 64d 60 60 60 60 60 60e 60 60 60 60 60 60f 5,5 5,5 5,5 5,5 5,5 5,5g. 8 8 8 8 8 8g.1 2 2 2 2 2 2h 75 80 85 89 89 95h1 6 9 10 10 12k 22 22 22 28 28 38l 43 52 57 60 60 65

Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —6 —6 —6

Drawing Amp. 16 321 MB 465 Poles 3 4 5 3 4 5Dim. in mm a 73,5 100 100 100 100 100

b 64 92 92 92 92 92c 52 58 58 61 61 60d 60 85 85 85 85 85e 52 77 77 77 77 77f 5,5 5,5 5,5 5,5 5,5 5,5g. 7 8 8 8 8 8g.1 2 2 2 2 2 2h 79 100 100 103 103 105k 31 31 31 44 44 54l 52 55 65 70 70 73l1 60 63 72 82 82 85

Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —6 —6 —6

The sizes for the entries on the drawings can be different to the real existing entry sizes.Subject to modification and amendments without prior notice. Errors and omissions excepted.

23

1 MB 466

Drawing Amp. 16 321 MB 466 Poles 3 4 5 3 4 5Dim. in mm a 73,5 100 100 100 100 100

b 64 92 92 92 92 92c 52 60 62 66 66 66d 60 85 85 85 85 85e 52 77 77 77 77 77f 5,5 5,5 5,5 5,5 5,5 5,5g. 7 8 8 8 8 8g.1 2 2 2 2 2 2h 84 100 106 109 109 113k 31 31 31 44 44 54l 52 55 65 70 70 73l1 60 63 72 82 82 85

Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —6 —6 —6

Drawings and dimensions

Drawing Amp. 16 321 MB 452 Poles 3 4 5 3 4 5Dim. in mm a 85 85 85 85 85 85

b 85 85 85 85 85 85c 57 59 60 68 68 72d 70 70 70 70 70 70e 70 70 70 70 70 70f 5,5 5,5 5,5 5,5 5,5 5,5g 8 8 8 8 8 8g.1 2 2 2 2 2 2h 87 91 99 105 105 110i 78 85 96 103 103 110k 39 34 33 53 53 41

I min. 57 64 70 78 78 78I max. 78 78 78 78 78 78

Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —10 —10 —10

angle

Page 24: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

1 MB 467 1 MB 468 for 61 mm Ø

1 MB 468 for 70 mm Ø 1 MB 550

1 MB 584

1 MB 5861 1 MB 622

2 MB 32 2 MB 36

2 MB 43 2 MB 68/853

Drawing Amp. 16 321 MB 467 Poles 3 4 5 3 4 5Dim. in mm a 75 75 75 85 85 85

b 75 75 75 75 75 75c 60 61 61 69 69 72d 60 60 60 60 60 60e 60 60 60 60 60 60f 5,5 5,5 5,5 5,5 5,5 5,5g. 8 8 8 8 8 8g.1 2 2 2 2 2 2h 83 88 95 99 99 105i 78 85 96 103 103 110k 21 21 21 28 28 38l 43 52 54 60 60 65

Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —6 —6 —6

Drawing Amp. 161 MB 468 Poles 3Dim. in mm a 69

b 57

c 55

k max. 30

h 87

l 61

l1 33,25

t 2-9

Terminal for cond. cross 1,5

section (mm2) min.-max. —4

Drawing Amp. 16 321 MB 468 Poles 4 5 3 4 5Dim. in mm a 81 81 81 81 81

b 66 69 71 71 80

c 58 55 66 66 64

k max. 33 max. 33 max. 33 max. 33 max. 33

h 100 102 101 101 108

l 70 70 70 70 70

l1 37.75 37.75 37.75 37.75 37.75

t 2-9 2-9 2-9 2-9 2-9

Terminal for cond. cross 1.5 1.5 2.5 2.5 2.5

section (mm2) min.-max. —4 —4 —6 —6 —6

Drawing1 MB 584

Dim. in mm

Drawing1 MB 5861

Dim. in mm

Drawing Amp. 16 321 MB 622 Poles 3 4 5 3 4 5Dim. in mm a 100 100 100 100 100 100

b 101 101 101 109 109 109c 117 125 131 157 157 160d 50 50 50 50 50 50e 84 84 84 92 92 92f1 5,3 5,3 5,3 5,3 5,3 5,3f2 5,3 5,3 5,3 5,3 5,3 5,3g 6,5 6,5 6,5 6,5 6,5 6,5h 131 131 132 148 148 148i 24,7 24,7 24,7 27,5 27,5 27,5M 25 (optional M20) 32 (optional M25)M* 2x25 (blind) to be cut out 2x25 (blind) to be cut out

Max. cable diam. (mm) 18 (M25) and 15 (M20) 25 (M32) and 18 (M25)Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —6 —6 —6

Drawing Amp. 16 322 MB 32 Poles 3 4 5 3 4 5Dim. in mm a 87 100 100 128 128 128

b 64 75 75 84 84 84c 93 106 110 133 133 135d 40 — — — — —d1 — 10,5 10,5 11 11 11e 50,5 59 59 68 68 68f 4,5 5 5 5,3 5,3 5,3g. 4 4 4 4 4 4h 122 133 135 169 169 170M 20 20 20 32 32 32M* 1x20 (blind) to be cut out 2x25 (blind) to be cut out

Max. cable diam. (mm) 15 15 15 18/25 18/25 18/25Terminal for cond. cross 1 1 1 2,5 2,5 2,5section (mm2) min.-max. —2,5 —2,5 —2,5 —6 —6 —6

Drawing Amp. 63 1252 MB 36 Poles 3 4 5 4 5Dim. in mm a 170 170 170 264 264

b 118 118 118 163 163c 171 171 171 205 205d 136 136 136 240 240e 104 104 104 140 140f 6,1 6,1 6,1 8,1 8,1g. 6 6 6 8 8h 250 250 250 355 355M 40 40 40 50 50M* 2x40 2x40 2x40 50 50α 25° 25° 25° 20° 20°

Max. cable diam. (mm) 32 32 32 38 38Terminal for cond. cross 4 4 4 16 16section (mm2) min.-max. —10 —10 —10 —35 —35

Drawing Amp. 16 322 MB 43 Poles 4 5 3 4 5Dim. in mm a 85 85 75 75 75

b 85 85 90 90 90c 104 106 115 115 117d 64 64 45 45 45d1 10 10 13 13 13e 64 64 78 78 78f 5,5 5,5 5,5 5,5 5,5g. 27 27 27 27 27g.1 2 2 1 1 1h 140 140 150 150 150l 50 50 55 55 55

Terminal for cond. cross 1 1 2,5 2,5 2,5section (mm2) min.-max. —2,5 —2,5 —6 —6 —6

Drawing Amp. 162 MB 68/853 Poles 5Dim. in mm a 75

b 75c 42d 60e 60f 5,5g. 7,3g.1 2k 13l 52

Terminal for cond. cross 1section (mm2) min.-max. —2,5

The sizes for the entries on the drawings can be different to the real existing entry sizes.Subject to modification and amendments without prior notice. Errors and omissions excepted.

24

Drawing Amp. 16 321 MB 550 Poles 3 4 5 3 4 5Dim. in mm a 225 225 225 225 225 225

b 168 168 168 168 168 168b1 130 130 130 130 130 130c 80 80 80 80 80 80c1 166 166 166 166 166 166c2 182 183 183 193 193 193d 204 204 204 204 204 204d1 145 145 145 145 145 145e 150 150 150 150 150 150f 7 7 7 7 7 7f1 Ø7 Ø7 Ø7 Ø7 Ø7 Ø7g 8 8 8 8 8 8

1 MB 551

Drawing Amp. 16 321 MB 551 Poles 3 4 5 3 4 5Dim. in mm a 225 225 225 225 225 225

b 168 168 168 168 168 168b1 130 130 130 130 130 130c 80 80 80 80 80 80c1 166 166 166 166 166 166c2 182 185 186 197 197 198d 204 204 204 204 204 204d1 145 145 145 145 145 145e 150 150 150 150 150 150f 7 7 7 7 7 7f1 Ø7 Ø7 Ø7 Ø7 Ø7 Ø7g 8 8 8 8 8 8

Drawings and dimensions

Page 25: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

2 MB 71

2 MB 173/2

2 MB 147

2 MB 155 2 MB 160

2 MB 166

2 MB 187/2 2 MB 215 for 61 mm Ø

2 MB 215 for 70 mm Ø 2 MB 221

5 MB 57

Drawing Amp. 16 322 MB 71 Poles 7 7Dim. in mm a 85 75

b 85 90c 79 90d 64 45d1 10 13e 64 78f 5,5 5,5g. 6 6g.1 2 2h 129 138

Terminal for cond. cross 1 2,5section (mm2) min.-max. —2,5 —6

Drawing Amp. 16 322 MB 173/2 Poles 3 4 5 3 4 5Dim. in mm a 85,7 85,7 85,7 85,7 85,7 85,7

b 85,7 85,7 85,7 85,7 85,7 85,7c 72 72 72 90 90 90d 69,5 69,5 69,5 69,5 69,5 69,5e 69,5 69,5 69,5 69,5 69,5 69,5f 5,5 5,5 5,5 5,5 5,5 5,5g. 11 11 11 11 11 11g.1 2 2 2 2 2 2l 32 36 36 47 47 47

Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —10 —10 —10

Drawing Amp. 16 322 MB 147 Poles 7 7Dim. in mm a 100 128

b 75 84c 110 135d — —d1 10,5 11e 59 68f 5 5,3g. 4 4h 135 170M 20 32M* 20 (blind) to be cut out 2x25 (blind) to be cut out

Max. cable diam. (mm) 15 18Terminal for cond. cross 1 2,5section (mm2) min.-max. —2,5 —4

Drawing Amp. 632 MB 155 Poles 3 4 5Dim. in mm a 110 110 110

b 106 106 106c 86 86 86d 90 90 90e 90 90 90f 5,5 5,5 5,5g. 12 12 12g.1 2 2 2k 28 28 28l 86 86 86

Terminal for cond. cross 6 6 6section (mm2) min.-max. —16 —16 —16

Drawing Amp. 16 322 MB 160 Poles 2 3 2 3Dim. in mm a 96 96 96 96

b 73 73 73 73c 74 74 74 74d 53 53 53 53d1 52 52 52 52d2 2 2 2 2e 62 62 62 62f 5,3 5,3 5,3 5,3g. 8 8 8 8h 116 116 116 116

Terminal for cond. cross 4 4 4 4section (mm2) min.-max. —10 —10 —10 —10

Drawing Amp. 63 1252 MB 166 Poles 3 4 5 3 4 5Dim. in mm a 110 110 110 130 130 130

b 106 106 106 130 130 130c 86 86 86 112 112 112d 90 90 90 104 104 104e 90 90 90 104 104 104f 5,5 5,5 5,5 6,5 6,5 6,5g. 12 12 12 18 18 18g.1 2 2 2 2 2 2k 28 28 28 28 28 28l 88.5 88.5 88.5 95 95 95s 113 113 113 132 132 132

Terminal for cond. cross 6 6 6 25 25 25section (mm2) min.-max. —16 —16 —16 —70 —70 —70

Drawing Amp. 16 322 MB 187/2 Poles 3 4 5 3 4 5Dim. in mm a 85,7 85,7 85,7 85,7 85,7 85,7

b 85,7 85,7 85,7 85,7 85,7 85,7c 72 72 72 90 90 90d 69,5 69,5 69,5 69,5 69,5 69,5e 69,5 69,5 69,5 69,5 69,5 69,5f 5,5 5,5 5,5 5,5 5,5 5,5g. 11 11 11 11 11 11g.1 2 2 2 2 2 2l 32 36 47 47 47 47s 71 79 89 94 94 102

Terminal for cond. cross 1,5 1,5 1,5 2,5 2,5 2,5section (mm2) min.-max. —4 —4 —4 —10 —10 —10

Drawing Amp. 16 322 MB 215 Poles 4 5 3 4 5Dim. in mm a 78 78 78 78 78

b 50 56 58 58 64

c 45 44 51 51 51

k max. 33 33 33 33 33

h 82 82 82 82 82

l 70 70 70 70 70

l1 37,75 37,75 37,75 37,75 37,75

† wall thicknesses 2-9mm wall thicknesses 2-9mm

Terminal for cond. cross 1,5 1,5 2,5 2,5 2,5

section (mm2) min.-max. —4 —4 —10 —10 —10

Drawing Amp. 162 MB 215 Poles 3 4 5Dim. in mm a 69 69 69

b 44 50 56

c 45 43 42

k max. 30 30 30

h 70 70 70

l 61 61 61

l1 33,25 33,25 33,25

† wall thicknesses 2-9mm

Terminal for cond. cross 1,5 1,5

section (mm2) min.-max. —4 —4

Drawing Amp. 16 322 MB 221 Poles 4 5 3 4 5Dim. in mm a 92.5 92.5 102 102 102

b 87 87 94 94 94

c 84.5 84.5 94 94 94

d 55.5 55.5 62 62 62

e 76 76 84 84 84

f1 5.3 5.3 5.3 5.3 5.3

f2 5.3 5.3 5.3 5.3 5.3

h 128 128 146 146 146

i 21,5 21,5 26 26 26

M 25x1.5 25x1.5 25x1.5 25x1.5 32x1.5

Drawing Amp. 16 325 MB 57 Poles 3 4 5 3 4 5

Dim. in mm a 200 200 200 200 200 200

b 110 110 110 110 110 110

c 47 50 51 59 59 60

d 190 190 190 190 190 190

e 100 100 100 100 100 100

f 5 5 5 5 5 5

g 13 13 13 13 13 13

k max. 56 56 56 56 56 56

The sizes for the entries on the drawings can be different to the real existing entry sizes.Subject to modification and amendments without prior notice. Errors and omissions excepted.

25

Drawings and dimensions

5 MB 59

Drawing Amp. 16 325 MB 59 Poles 3 4 5 3 4 5

Dim. in mm a 200 200 200 200 200 200

b 110 110 110 110 110 110

c 46 49 46 56 56 53

d 190 190 190 190 190 190

e 100 100 100 100 100 100

f 5 5 5 5 5 5

g 13 13 13 13 13 13

k max. 56 56 56 56 56 56

Page 26: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

Part no. Part no. Part no. Part no. Part no. Part no. Part no. Part no. Part no. Part no. Part no.page page page page page page page page page page page

Index of part numbers

264 6268 6269 6277 6278 6279 6280 6281 6282 6286 6287 6288 6289 6290 6291 6292 6293 6294 6298 6299 6300 6315 6318 9319 9321 9322 9325 9327 9328 9331 6332 6333 6334 6335 6336 6338 9339 9340 6341 6342 6343 6344 6345 6346 6347 6348 6352 6353 6354 6355 6356 6357 6359 6360 6361 6362 6363 6364 6366 6367 6368 6392 6393 6394 6396 9397 9398 6399 6400 6401 6402 6403 6404 6405 6406 6410 6411 6412 6418 5419 5420 5421 5422 5509 7510 7511 7512 7513 7514 7518 7519 7521 7522 7523 7524 7525 7526 7530 7531 7539 7

540 7541 7542 7543 7544 7548 7549 7550 7551 7552 7553 7554 7555 7556 7560 7561 7562 7577 9578 9584 9585 9586 9590 9591 9597 9598 9599 9603 9604 9610 9611 9612 9616 9617 9623 9624 9625 9629A 9630A 9636A 9637A 9638A 9642A 9643A 9649A 9650A 9651A 9681A 9682A 9688A 9689A 9690A 9694A 9695A 9701A 9702A 9703A 9711 6712 6717 6719 6725 7731 7733 10734 10735 10736 10737 10738 10739 10740 10741 10742 10743 10744 10745 10746 10747 10748 10749 10750 10751 10752 10761 7763 7800 6801 6802 6803 6804 6810 6812 6813 6815 6816 6817 6819 6821 6822 6825 6

826 6827 6829 6830 6831 6832 6834 6835 6836 6837 6838 6839 6840 6843 6844 6854 9856 4859 9891 6903 4905 4907 5919 6924 6931 6932 6933 6935 6938 6939 6942 6945 6947 6948 6949 6951 6952 6972 6979 7980 7987 5988 5989 5993 7994 7997 5998 51035 101040 101045 101050 101055 101060 101065 101070 101075 101080 101081 41103 41107 61122A 41123A 41124A 41126A 41127A 41128A 41131 51132 51133 51135 51136A 41137A 41138A 41139A 41140A 41141A 41143A 41144A 41145A 41146A 41147A 41148A 41149A 41150A 41151A 41153A 41154A 41155A 41166 51177 41178 41216 61217 61246A 41247A 41248A 41250A 41251A 41252A 41260A 4

1261A 41262A 41263A 41264A 41265A 41267 41268 41270 91271 91272 91273 91340 51341 51342 51343 51345 51346 51347 51348 51365 41366 41367 41368 41369 41371 41372 41373 41384 41385 41386 41388 41389 41390 41394 41395 41396 41397 41398 41399 41410 61411 61418 41419 41420 41421 41422 41423 41424 41425 41438 71455 41456 41457 41459 41460 41461 41462 41463 41464 41465 41466 41467 41471 41472 41473 41474 41475 41476 41477 41478 41479 41483 41484 41485 41489 41490 41491 41492 41493 41494 41495 41496 41498 41499 41500 41501 41502 41503 41504 41505 41506 41551 41555 41556 41557 41631 51632 51633 51636 51637 5

1638 51642 51643 51667 51668 51669 51672 51673 51674 51678 51679 51688 61700 51701 51702 51703 51704 51707 51708 51709 51710 51711 51712 51716 51717 51719 51720 51721 51723 51724 51730 51733 51734 51735 51738 51739 51740 51744 51745 51746 51750 51751 51755 51756 51786 51787 51788 51789 51790 51791 51795 51796 51797 51801 51802 51803 51804 51805 51808 51809 51810 51811 51812 51813 51814 51818 51819 51820 51825 91831 91832 91835 91837 91838 91844 91845 91848 91850 91851 51852 51855 51856 51860 51861 51955 91961 91962 91965 91967 91968 91974 91975 91978 91980 91981 61982 61983 61984 62123A 132162A 4

2166 102167 102175B 132177A 132179A 42180A 42181A 42212 102213 102255 102296 102317 102324 102405 102406 102459 102460 102478 92511 92692 132845 92852 92855 92860 92864 92870 92883 103030 43031 43034 43036 43041 43045 43072 43093 43110 43112 43136 43153 43197 43200 43254 43266 63306 63312 63319A 93322 93331 53338 93339 93340 93341 93342 93343 93345 93346 93347 93348 93350 93355 93356 93380 43385 53413 63424 63449 43451 43454 43473 53485 53517 93523 93524 43575 43583 63646 63656 63658 63665 63704 63717 93718 133776 103777 103783 103784 103794 63796 63799 63807 63809 63811 63819 63821 63823 63829 63830 63832 63839 63841 6

3844 63851 63853 63855 63859 73860 73862 73869 73871 73873 73879 73881 73883 73887 73888 73891 73896 73897 73899 73905 73907 73909 73913 103916 103980 63981 63987 64101 114102 114103 114105 114106 114107 114108 114110 114111 114112 114113 114115 114116 114117 114118 114120 114122 114125 114127 114130 114132 114133 114135 114137 114138 114140 114141 114142 114143 114145 114146 114147 114148 114150 114162 114163 114165 114167 114168 114170 114171 114172 114173 114175 114177 114178 114180 114233 114237 114238 114247 114254 114262 114263 114273 114274 114275 114970 114971 114972 114973 114974 114976 114977 114979 114980 115099A 85100A 85102A 85103A 85104A 85105A 85107A 8

5108A 85109A 85110A 85112A 85113A 85457A 85459A 85460A 85462A 85536 105599A 85600A 85602A 85603A 85604A 85605A 85607A 85608A 85610A 85613A 85615A 85618A 85630A 85633A 85635A 85638A 85640A 85643A 85691A 85692A 85696A 85743A 85785 105792A 135793A 85887A 85888A 85911A 85924A 85925A 85946A 135955A 85956A 85959A 86059A 86062A 86106 106569 86571 87000 87002A 87010A 87011A 87012A 87050 87060 87061 107213 87216 87217 87218 87219 87220 87221 87222 87238 87239 87240 87241 87242 87243 87244 87502 87503 87504 87505 87507 87511 87512 87513 87514 87516 87520 87521 87523 87524 87526 87530 87531 87533 87534 87536 87602 87603 87604 87605 87607 87611 87612 87613 8

7614 87616 87620 87621 87623 87624 87626 87628 87629 87633 87634 87636 89104 59105 59106 59120 59121 59122 59140 59141 59142 59150 59151 59152 59170 59171 59172 59180 59181 59182 59300 49301 49302 49320 49321 49322 49340 49341 49342 49350 49351 49352 49370 49371 49372 49380 49381 49382 49530 109531 109532 109562 139590 109591 109592 1010081 1210082 1210083 1210718 1210749 1210751 1210754 1210755 1210837 1210838 1210839 1210840 1210841 1210842 1210843 1210844 1210845 1210846 1211010 1211011 1211012 1211013 1211030 1211031 1211032 1211033 1211060 1211061 1211081 1211310 1211311 1211312 1211313 1211330 1211331 1211332 1211333 1211511 1211512 1211531 1211532 1213101 613102 613105 613106 6

13111 613112 613201 613202 613203 613204 613205 613206 613210 613211 613212 613215 613216 613217 613218 613219 613223 613224 613225 614101 714102 714105 714106 714111 714112 714201 714202 714203 714204 714205 714206 714210 714211 714212 714215 714216 714217 714218 714219 714223 714224 714225 720970 921241 941404 1175001 1275006 1275011 1275016 1275021 1275026 1275031 1275036 1275041 1275046 1275091 1275096 1275101 1275106 1275111 1275116 1275121 1275126 1275131 1275136 1275201 1275206 1275211 1275216 1275221 1275226 1275231 1275236 1275241 1275246 12900946 17910031 17920011 16920210 16920821 17930011 16930022 17930031 17930038 16931237 17940027 13940028 17940809 16950004 16950022 16960042 17970005GE 16

1 42 43 64 65 76 713A 614A 615A 716A 731 532 533 634 635 736 7100 4101 4102 4103 4104 4105 4109 4110 4111 4121 7122 7125 7126 7128A 4129A 4130A 4131A 4132A 4134A 4135A 4136A 4137 4138 4139 4141 4142 4143 4147A 6148A 6149A 6151A 6152A 6159 6160 6163 6164 6179A 7180A 7181A 7193A 7194A 7203A 4204A 4205A 4207A 4208A 4209A 4210A 4211A 4212A 4214A 4215A 4216A 4217A 4218A 4219A 4220A 4221A 4222A 4226A 4227A 4228A 4229A 4230A 4231A 4232A 4233A 4234A 4238A 4239A 4240A 4247 6248 6249 6250 6251 6252 6256 6257 6259 6260 6261 6262 6263 6

26

Page 27: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

27

BMW motorcycle plant, Berlin – Germany AIDAbella, Jos. L. Meyer Werft, Papenburg – Germany

Formula 1 circuit, Manama – Bahrain

Port of Salalah – Oman Container Terminal, Le Havre – France

Constitution, Heerema Marine Contractors – Netherland

References

Page 28: Industrial plugs and sockets · Poland Russia Sweden Switzer- land Slovakia Spain South Africa Czech Republic Hungary PR China USA. 3 ... Highest quality, reliability, safety, power

Made in GermanyMade in Germany

Service by MENNEKES®. Always well informed.

MENNEKES Elektrotechnik GmbH & Co. KG Industrial plugs and sockets

Aloys-Mennekes-Str. 1 D-57399 Kirchhundem / Germany

Tel. + 49 (0) 27 23 / 41-1 Fax + 49 (0) 27 23 / 41-2 14 E-Mail [email protected] Internet www.MENNEKES.de

Refer to our brochures and catalogues to keep up to date.

Download the latest versions from our website in practical

PDF format or request print copies by phone or E-Mail.

AMAXX®. Receptacle combinations for energy, Industrial Ethernet and Automation.

MENNEKES catalogueScrewless connections.For CEE plugs, connectors and receptacles.

PowerTOP® Xtra. Plugs and connectors for toughest conditions.

1020

00

DS

10TA

08.

14V

For further information please visit our homepage:

www.MENNEKES.de Request brochures by phone at:

+49 (0) 27 23 / 41-1 Request brochures by E-Mail to:

[email protected]