Etherbus Hardware Manual Page 1 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
USER MANUAL
Etherbus®
(EB Series) Industrial Ethernet PoE Switch,
Injectors, Splitter and More
Hardware Guide
Contents at a Glance:
Section 1 General Information ………………………………………………. Page 3
Section 2 LED Indicators …………………………………………………….. Page 4
Section 3 Installation / Mounting …………………………………………… Page 6
Section 4 Power Wiring ………………………………………………………. Page 10
Section 5 Communication Wiring ………………………………………….. Page 15
Section 6 Technical Specifications ………………………………………… Page 18
Section 7 Service Information ………………………………………………. Page 22
This manual applies to the following products:
EB-5ES-PSE-# Industrial PoE 5-port unmanaged Ethernet switch
EB-PSE-48V-2 Industrial PoE power injector for 2 channels
EB-PSE-24V-1 Industrial PoE power injector with built-in 24V to 48V converter
EB-PD-24V-1 Industrial PoE splitter converts 48V to 24V
EB-PD-UPS-1 Industrial PoE splitter converts 48V to 14V
EB-PS-4824-13 Industrial DC / DC power converter for 48V to 24V
Etherbus Hardware Manual Page 2 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
RED LION Protected Technology Policy - RED LION protects your investment in RED LION systems with
long-term planned technology and our unique Protected Technology Policy. We will continue to support the specified
capabilities of standard RED LION products for at least five years (twenty years for Industrial Managed Switches). We
plan each product improvement and new feature to be upward compatible with existing designs and installations. Our
goals are to make each new software release bring new power to your RED LION systems and have every existing
feature, applications program and data file continue to work. We protect your investment even further with a liberal five-
year trade-in policy. Exchange standard products for upgraded versions of the same product to take advantage of new
features and improvements at any time for five years. A prorated trade-in allowance will be given for your existing unit.
RED LION protects your long-term productivity with state-of-the-art planned technology and continued support.
RED LION Statement of Limited Warranty - RED LION, manufacturer of RED LION products, warrants to
Buyer that products, except software, manufactured by RED LION will be free from defects in material and workmanship.
RED LION's obligation under this warranty will be limited to repairing or replacing, at RED LION's option, the defective
parts within one year of the date of installation, or within 18 months of the date of shipment from the point of manufacture,
whichever is sooner. Products may be returned by Buyer only after permission has been obtained from RED LION. Buyer
will prepay all freight charges to return any products to the repair facility designated by RED LION. This limited warranty
does not cover losses or damages which occur in shipment to or from Buyer or due to improper installation, maintenance,
misuse, neglect or any cause other than ordinary commercial or industrial applications. In particular, RED LION makes
no warranties whatsoever with respect to implied warranties of merchantability or fitness for any particular purpose. All
such warranties are hereby expressly disclaimed. No oral or written information or advice given by RED LION or RED
LION’s representative shall create a warranty or in any way increase the scope of this warranty. This limited warranty is in
lieu of all other warranties whether oral or written, expressed or implied. RED LION's liability shall not exceed the price of
the individual units, which are the basis of the claim. In no event shall RED LION be liable for any loss of profits, loss of
use of facilities or equipment, or other indirect, incidental or consequential damages.
INSTALLATION AND HAZARDOUS AREA WARNINGS - These products should not be used to
replace proper safety interlocking. No software-based device (or any other solid-state device) should ever be
designed to be responsible for the maintenance of consequential equipment or personnel safety. In parti cular,
RED LION disclaims any responsibility for damages, either direct or consequential, that result from the use of
this equipment in any application. All power, input and output (I/O) wiring must be in accordance with Class I,
Division 2 wiring methods and in accordance with the authority having jurisdiction.
WARNING
(EXPLOSION HAZARD)
SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1,
DIVISION 2 (ZONE 2).
WARNING
(EXPLOSION HAZARD)
WHEN IN HAZARDOUS LOCATIONS, DISCONNECT POWER BEFORE REPLACING
OR WIRING UNITS.
WARNING
(EXPLOSION HAZARD)
DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF
OR THE AREA IS KNOWN TO BE NONHAZARDOUS.
FCC Statement - This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the
receiving antenna; Increase the separation between the equipment and receiver; Connect the equipment into an outlet on
a circuit different from that to which the receiver is connected; Consult the dealer or an experienced radio/TV technician
for help.
Copyright & Trademarks - Etherbus® is a registered trademark of SIXNET, LLC. Copyright 2007 SIXNET, LLC.
All Rights Reserved.
Note: All information in this document is subject to change without notice.
Etherbus Hardware Manual Page 3 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Section 1 General Information
Overview
This manual will help you install and maintain these Etherbus industrial Power over Ethernet
(PoE) devices. These devices support standard IEEE 802.3af Power over Ethernet (PoE) and
will work with any device that also supports this standard. Installation of the Etherbus devices
is very easy and they will begin to operate as soon as they are powered up. For all models
there are no user settings so they are truly plug and play.
The following products are covered by this manual:
Model Type Power In Power Out PSE Ports PD Ports
EB-5ES-PSE-# Switch 48 VDC 48V PoE 4 -
EB-PSE-48V-2 Injector 48 VDC 48V PoE 2 -
EB-PSE-24V-1 Injector 24 VDC 48V PoE 1 -
EB-PD-24V-1 Splitter 48V PoE 24 VDC - 1
EB-PD-UPS-1 Splitter 48V PoE 14 VDC - 1
EB-PS-4824-13 Converter 48 VDC 24 VDC - -
Key:
PD = Powered Device (accepts 48V PoE power)
PSE = Power Sourcing Equipment (puts out 48V PoE power)
Reference
Images
EB-5ES-PSE-1
EB-PSE-48V-2
EB-PSE-24V-1
EB-PD-24V-1
EB-PS-4824-13
Safety
Standards
These industrial Ethernet devices meet the following standards plus others:
Electrical safety – UL 508, CSA C22; EN61010-1 (IEC1010)
Emissions – FCC part 15, ICES 003, EN55022; Class B
Immunity – IEC61326-1
Hazardous locations – ANSI / ISA12.12.01, CSA C22.2/213 (Class 1, Div. 2), Groups A, B,
C, D; ATEX IEC60079-0, -15 (Zone 2)
Install the Managed Switches in accordance with local and national electrical codes.
Lightning Danger: Do not work on equipment during periods of lightning activity.
Do not connect a telephone line into one of the Ethernet RJ45 connectors.
Etherbus Hardware Manual Page 4 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Section 2 LED Indicators
Overview The Etherbus devices have several LEDs to indicate the power and operational status of the
unit. See below for the location of these LEDs and an explanation of their operation.
EB-5ES-PSE-1
EB-5ES-PSE-2ST
EB-PSE-48V-2
EB-PSE-24V-1
EB-PD-24V-1
EB-PS-4824-13
Typical LED Location for Etherbus Products
(Note: The LED locations may vary slightly from these images.)
Etherbus Hardware Manual Page 5 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Power LED
On all models (except the splitter) there is one power LED that is ON if either power input (P1
or P2) has valid power applied to it. If the power LED is OFF then no power is being applied
to the unit.
On the splitter the power LED will be ON when PoE power is detected on the incoming
Ethernet line. It will be OFF if no PoE power is detected.
ACT / LNK
LED
This is the Yellow LED in the RJ45 ports of the Etherbus switch model EB-5ES-PSE-#. It
indicates the Link and Activity status of the port.
ON (yellow) (not flashing)
Indicates that there is a proper Ethernet connection (Link) between the
port and another Ethernet device, but no communications activity is
detected.
ON (yellow) (flashing)
Indicates that there is a proper Ethernet connection (Link) between the
port and another Ethernet device, and that there is communications
activity.
OFF Indicates that there is not a proper Ethernet connection (Link) between
the port and another Ethernet device. Make sure the cable has been
plugged securely into the ports at both ends.
Speed 10/100
LED
This is the Green LED in the RJ45 connector of Port 5 on the Etherbus switch model EB-
5ES-PSE-1. It indicates the Speed of the uplink port.
ON (green) A 100 Mbps (100BaseT) connection is detected.
OFF A 10 Mbps (10BaseT) connection is detected.
Fiber Optic
Port LED
This is the Green LED above the fiber port on the Etherbus switch model EB-5ES-PSE-2 or -
3. It indicates the Link status of the fiber optic port.
ON (green) A 100 Mbps (100BaseF) connection is detected.
OFF No fiber connection is detected.
PoE LED
This is the Green LED that is either integrated into the RJ45 port (on switch models) or is
below the PoE ports (on injector models). It indicates the PoE status of the port.
ON (green) A valid Powered Device (PD) is detected and the switch or injector is
sourcing power on this port.
OFF No valid Powered Device (PD) is detected so no power is being sourced.
Periodically
Blinks ON
No valid Powered Device (PD) is detected or the connected device is
drawing too little current (<10 mA) so no power is being sourced.
However, the switch or injector is periodically looking for a valid device.
This condition may occur when you have connected a PoE splitter but it
has not been connected to a load yet. Once the connected device (such
as a splitter) is loaded and draws more than 10 or 15 mA then power
will be sourced.
Error Code
Blink
Some models may blink an error code. If you see the same sequence of
blinks repeatedly then contact RED LION for more information.
Etherbus Hardware Manual Page 6 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Section 3 Installation
Overview
These industrial Ethernet PoE devices can be snapped onto a standard DIN rail (EN50022) or
screwed directly to a flat panel. Refer to the mechanical drawings below to properly mount your
switch.
Note: Make sure to allow enough room to route your Ethernet copper or fiber optic cables.
DIN Rail
Mounting
Recommended DIN rail mounting steps: 1. Hook top back of unit over the din rail.
2. Push bottom back onto the din rail until it snaps into place.
Recommended DIN rail removal steps: A. Insert screwdriver into din clip and pry until it releases from the din rail.
B. Unhook top of unit from din rail.
1
2
B
A
Mounting
Removal
Etherbus Hardware Manual Page 7 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Dia. 0.15"(0.38 cm)
Use for directpanel mountingto a flat surface
3.95"
[10.03 cm]
1.98"
[5.02 cm]
1.98"
[5.02 cm]
1.00"
[2.54 cm]
3.26"
[8.28 cm]
0.06" [0.15 cm]
0.40" (1.02 cm)Typical for
SC or ST fiber
Removable Screw Block
Snaps to standardDIN rail EN50022
(35 mm)
1.01"
[2.57 cm]
1.01"
[2.57 cm]
4.20"
[10.67 cm]
EB-5ES-PSE
2.90"
[7.35 cm]
Mechanical Dimensions for the Etherbus Switch
Dia. 0.15"(0.38 cm)
Use for directpanel mountingto a flat surface
3.95"
[10.03 cm]
1.98"
[5.02 cm]
1.98"
[5.02 cm]
1.00"
[2.54 cm]
3.26"
[8.28 cm]
0.06" [0.15 cm]
Removable Screw Block
Snaps to standardDIN rail EN50022
(35 mm)
1.01"
[2.57 cm]
1.01"
[2.57 cm]
4.20"
[10.67 cm]
EB-PSE-48V-# 2.90"
[7.35 cm]
Mechanical Dimensions for the Etherbus Dual Injector
Etherbus Hardware Manual Page 8 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Dia. 0.15"(0.38 cm)
Use for directpanel mountingto a flat surface
3.95"
[10.03 cm]
1.98"
[5.02 cm]
1.98"
[5.02 cm]
1.00"
[2.54 cm]
3.26"
[8.28 cm]
0.06" [0.15 cm]
Removable Screw Block
Snaps to standardDIN rail EN50022
(35 mm)
1.01"
[2.57 cm]
1.01"
[2.57 cm]
4.20"
[10.67 cm]
EB-PSE-24V-# 2.90"
[7.35 cm]
Mechanical Dimensions for the Etherbus Injector with DC/DC Converter
Dia. 0.15"(0.38 cm)
Use for directpanel mountingto a flat surface
3.95"
[10.03 cm]
1.98"
[5.02 cm]
1.98"
[5.02 cm]
1.00"
[2.54 cm]
3.26"
[8.28 cm]
0.06" [0.15 cm]
Removable Screw Block
Snaps to standardDIN rail EN50022
(35 mm)
1.01"
[2.57 cm]
1.01"
[2.57 cm]
4.20"
[10.67 cm]
EB-PD-xxx-# 2.90"
[7.35 cm]
Mechanical Dimensions for the Etherbus Splitter
Etherbus Hardware Manual Page 9 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Dia. 0.15"(0.38 cm)
Use for directpanel mountingto a flat surface
3.95"
[10.03 cm]
1.98"
[5.02 cm]
1.98"
[5.02 cm]
1.00"
[2.54 cm]
3.26"
[8.28 cm]
0.06" [0.15 cm]
Removable Screw Block
Snaps to standardDIN rail EN50022
(35 mm)
1.01"
[2.57 cm]
1.01"
[2.57 cm]
4.20"
[10.67 cm]
EB-PS-4824-132.90"
[7.35 cm]
Mechanical Dimensions for the Etherbus DC/DC Converter
Etherbus Hardware Manual Page 10 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Section 4 Power Wiring
Overview
These industrial Ethernet devices can be powered from the same DC source (typically 24
VDC or 48 VDC) that is used to power your other devices. Refer to the details below on how
to properly wire power to or from your Etherbus devices.
Screw Torque
When tightening the screws be careful to tighten to a maximum torque of 3.48 lb-in.
Switch Power
The Etherbus switch accepts power in the range of 10 to 56 VDC (48 VDC nominal) and can
source 48 VDC power to four PoE devices. For PoE sourcing (PSE) operation, the power
must be in the range of 45 to 56 VDC. Otherwise, the switch will function properly as an
industrial Ethernet switch but will not source any PoE power. For PoE operation, make sure
your 48 VDC supply is rated for at least 16 Watts per PoE channel being sourced, plus some
overhead for the switch. It is recommended that a supply with 75 Watts or more of power be
used. The Etherbus switch supports dual power inputs allowing you to connect a backup
power source. The backup power should have the same voltage as the primary power. Make
your power connections as shown in the diagram below.
The PoE ports when sourcing power will put out 48 VDC* (see note below) over the signal
pair of the RJ45 connection:
o V+ on RX lines 1 and 2
o V- on TX lines 3 and 6
o Lines 4, 5, 7 and 8 are unused
P2 P1
One DC Supply
(10 - 56 VDC)
+ -
Chassis
GND
(panel)
-+
Two DC Supplies
(10 - 56 VDC)
EB-5ES-PSE Single DC Power
EB-5ES-PSE Dual DC Power
+ -
Chassis
GND
(panel)
+ + + +P1P2
* Note: When the supply voltage is 45 to 47 VDC then the power output for the PoE will be
the same as the supply voltage. For example, if the supply voltage is 45 VDC then the PoE
output will also be 45 VDC. If the supply voltage is 48 to 50 VDC then the PoE output will
be regulated at 48 VDC.
Etherbus Hardware Manual Page 11 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Dual Injector
Power
The Etherbus Dual Injector accepts power in the range of 45 to 56 VDC (48 VDC nominal)
and can source 48 VDC power to two PoE devices. Make sure your 48 VDC supply is rated
for at least 16 Watts per PoE channel being sourced. Make your power connections as
shown in the diagram below.
There are two models of this injector:
The standard -2A model when sourcing PoE power will put out 48 VDC* (see note below) over
the unused pair of lines in the RJ45 connection:
o V+ on lines 4 and 5
o V- on lines 7 and 8
o TX on lines 3 and 6
o RX on lines 1 and 2
The -2B model (special order) when sourcing PoE power will put out 48 VDC* (see note
below) over the signal pair of lines in the RJ45 connection:
o V+ on RX lines 1 and 2
o V- on TX lines 3 and 6
o Lines 4, 5, 7 and 8 are unused
DC Supply
(45 - 56 VDC)
+ -
EB-PSE-48V DC Power Input
Chassis
GND
(panel)
+
* Note: When the supply voltage is 45 to 47 VDC then the power output for the PoE will be
the same as the supply voltage. For example, if the supply voltage is 45 VDC then the PoE
output will also be 45 VDC. If the supply voltage is 48 to 56 VDC then the PoE output will
be regulated at 48 VDC.
Etherbus Hardware Manual Page 12 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Single Injector
Power
The Etherbus Single Injector has a built-in DC to DC converter allowing it to accept power in
the range of 18 to 30 VDC (24 VDC nominal) and source 48 VDC power to one PoE device.
Make sure your 24 VDC supply is rated for at least 20W. Make your power connections as
shown in the diagram below.
There are two models of this injector:
The standard -1A model when sourcing PoE power will put out 48 VDC over the unused pair
of lines in the RJ45 connection:
o V+ on lines 4 and 5
o V- on lines 7 and 8
o TX on lines 3 and 6
o RX on lines 1 and 2
The -1B model (special order) when sourcing PoE power will put out 48 VDC over the signal
pair of lines in the RJ45 connection:
o V+ on RX lines 1 and 2
o V- on TX lines 3 and 6
o Lines 4, 5, 7 and 8 are unused
P2 P1
One DC Supply
(18 - 30 VDC)
+ -
Chassis
GND
(panel)
-+
Two DC Supplies
(18 - 30 VDC)
EB-PSE-24V Single DC Power
EB-PSE-24V Dual DC Power
+ -
Chassis
GND
(panel)
+ + + +P1P2
Etherbus Hardware Manual Page 13 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Splitter Power
The Etherbus Splitter accepts 48 VDC from a PoE line and outputs an isolated and regulated
24 VDC @ 13 Watts to power your standard Ethernet (non-PoE) devices. Just connect your
incoming PoE line (supports both power over the signals lines or power over the unused lines)
to the PoE IN port. The splitter will convert the 48 VDC to 24 VDC and make it available on
the pluggable screw terminal block. Make your power connections as shown in the diagram
below.
24 VDC
Load
+ -
EB-PD-24V DC Power Output
Chassis
GND
(panel)
+
The –UPS model (special order) is the same as above but outputs 14 VDC instead of 24
VDC. The 14 VDC can be used to power 12V or 14V devices, and it can be used to charge a
12V seal-lead-acid battery for power backup. Make your power connections as shown in the
diagram below.
12-14 VDC Load+ -
EB-PD-UPS DC Power Output
Chassis
GND
(panel)
+
-+Optional
12V Battery
Etherbus Hardware Manual Page 14 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
DC/DC
Converter
Power
The Etherbus DC to DC converter accepts power in the range of 45 to 56 VDC and outputs an
isolated and regulated 24 VDC @ 13 watts. This convenient accessory allows you to power
typical 24 VDC industrial devices from your 48 VDC system power. Make your input and
output power connections as shown below.
+ +
45 - 56
VDC
Input
+ +
24
VDC
Output
EB-PS-4824-13 Power Connections
Etherbus Hardware Manual Page 15 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Section 5 Communication Wiring
PoE Switch
Operation
Unlike an Ethernet hub that broadcasts all messages
out all ports, the Etherbus industrial Ethernet PoE
switch will intelligently route Ethernet messages only
out the appropriate port. The major benefits of this are
increased bandwidth and speed, reduction or
elimination of message collisions, and deterministic
performance when tied with real-time systems.
The switch can support 10BaseT (10 Mbps) and
100BaseT (100 Mbps) on the RJ45 ports. Each of
these ports will independently auto-sense the speed
and duplex, allowing you to interface to fast (100
Mbps) Ethernet devices or legacy (10 Mbps).
Optionally you can also have a 100BaseF (100 Mbps)
fiber optic port.
PoE Switch
Overview
The Etherbus industrial Ethernet PoE switch provides connections to standard Ethernet
devices such as PLCs, Ethernet I/O, industrial computers and much more. Two types of
communication ports may be found on these switches: RJ45 (copper) Ethernet ports or fiber
optic Ethernet ports.
Switch RJ45
Port Wiring
Use data-quality (not voice-quality) twisted pair cable rated category 5 (or better) with
standard RJ45 connectors. For best performance use shielded cable. Straight through or
crossover RJ45 cable can be used regardless of the device the switch is to be connected to
as all the ports are capable of auto-mdi/mdix-crossover detection.
The RJ45 Ethernet port connector bodies on these products are metallic and are connected
to the Chassis GND terminal. Therefore, shielded cables may be used to provide further
protection. To prevent ground loops, the cable shield should be tied to the metal connector
body at one end of the cable only. Electrical isolation is also provided on the Ethernet ports
for increased reliability.
For Reference
Only.
Either cable
wiring will work!
Straight-thru Cable Wiring Cross-over Cable Wiring
Pin 1 Pin 1 Pin 1 Pin 3
Pin 2 Pin 2 Pin 2 Pin 6
Pin 3 Pin 3 Pin 3 Pin 1
Pin 6 Pin 6 Pin 6 Pin 2
Standard
Ethernet
Plug & Connector
Pin Positions
RJ45 Cable
Distance
The maximum cable length for 10/100/1000BaseT with Cat 5E twisted pair cables is typically
100 meters (328 ft.).
Etherbus Hardware Manual Page 16 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Fiber Wiring
Guidelines
The Etherbus industrial Ethernet PoE switch optionally has one 100 Mbps (100Base-FX)
multimode or singlemode fiber ports. The maximum segment length is up to 120 km or more
depending on the type of fiber optic transceiver installed in the switch. Refer to the technical
specifications for details. Or contact RED LION for the available fiber optic transceivers.
Each fiber optic port on the switch is comprised of a pair of SC or ST style connectors. For
each fiber port there is a transmit (TX) and receive (RX) signal. When making your fiber optic
connections, make sure that the transmit (TX) port of the switch connects to the receive (RX)
port of the other device, and the receive (RX) port of the switch connects to the transmit (TX)
port of the other device.
Use standard fiber optic wiring techniques (not covered by this manual) to make your
connections. The corresponding ACT/LNK LED will be ON solid when you have made a
proper connection. See images below for typical fiber optic port placement.
Duplex
Operation
The RJ45 ports will auto-sense for Full or Half duplex operation, while the fiber port is
configured for full duplex operation. Note: Fiber devices with half duplex settings should still
communicate with the switch. If otherwise then please contact RED LION.
Network
Device Check
These industrial Ethernet switches are capable of supporting 10/100BaseT on the RJ45
(copper) ports and 100BaseF on the fiber optic ports. Make sure you connect the appropriate
devices to each port.
Verifying
Connectivity
After all Ethernet and/or fiber connections are made, check the LED’s corresponding to the
ports that each of the devices are connected to. Ensure that for each port that is in use, the
LED is on or blinking. If a port LED is off, go back and check for connectivity problems
between that port and the network device connected.
Typical
SC Style
Connector
Typical
ST Style
Connector
Etherbus Hardware Manual Page 17 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
PoE Injector
RJ45 Wiring
The Etherbus industrial Ethernet PoE injectors have two RJ45 connectors per PoE channel.
See the diagram below. One RJ45 port is labeled as ETH IN (for Ethernet Input) and the other
is Labeled as PoE OUT (for PoE Output). Connect your standard Ethernet (non-PoE) cable to
the ETH IN port. This cable is typically coming from an Ethernet switch or router. Then
connect the cable to be run to your PoE Powered device (PD) to the PoE OUT port. The PoE
LED will be ON when power is being sourced to your device.
PoE Splitter
RJ45 Wiring
The Etherbus industrial Ethernet PoE splitter has two RJ45 ports. See the diagram below.
One RJ45 port is labeled PoE IN (for PoE input) and the other is labeled ETH OUT (for
Ethernet output). Connect the cable from your PoE (PSE) switch or injector to the PoE IN
port. Then connect the cable to be run to your standard Ethernet (non-PoE) device to the
ETH OUT port which does not have any power on it.
Etherbus Hardware Manual Page 18 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Section 6 Technical Specifications
Technical
Specs
Here are the hardware technical specifications for the products covered by this manual.
Please contact RED LION if additional information is required.
All specifications are subject to change without notice.
Etherbus Switch Performance Specifications
Model EB-5ES-PSE-#
General Unmanaged, store & forward
Ethernet protocols supported All IEEE 802.3
Ethernet switch ports 5 total with 4 PoE (PSE)
RJ45 ports (shielded) 10/100BaseTX
RJ45 speed (10 or 100 Mbps) Auto-negotiation
RJ45 MDI/MDIX and TD/RD Auto-crossover and auto-polarity
Ethernet isolation 1500 VRMS 1 minute
Fiber optic port speed / duplex 100BaseF (100 Mbps) / full duplex
Fiber optic port wavelength 1300 nm (others available)
Fiber multimode (mm) typical 50 or 62.5/125 um (SC or ST)
Fiber singlemode (sm) typical 9 or 10/125 um (SC or ST)
Fiber max. distance (full duplex)
(see web for more details)
4 km (mm), 20 (sm) or 40 km (long haul) or more (contact RED
LION)
Typ. latency for 100 Mbps ports 5 us + frame time Varies on load
MAC addresses and bandwidth 1024 and 3.2 Gbps
Power In and PoE Out Redundant input terminals
Power input with reverse polarity protection 10-30 VDC with no PoE output
45-56 VDC for PoE output
Switch power consumption
(typical all ports active at 100 Mbps)
2.0 W (5-port without fiber) + PoE
3.0 W (5-port with 1 fiber) + PoE
PoE power consumption Up to 15.4 W per port
RJ45 pin assignments for PoE TX/V- (3, 6); RX/V+ (1, 2)
Power input transient protection 15,000 watts peak
Power input spike Protection 5,000 watts (10 times for 10 uS)
PoE operation Auto power management
PoE disconnect mode DC disconnect
PoE auto-detection Per IEEE 802.2af
PoE protection Over-temperature, over-current, over/under-voltage and transient
Environmental Truly industrial design
Operating temperature range -40 to +75 °C (cold startup @ -40)
Storage temperature range -40 to +85 °C
Humidity (non-condensing) 5 to 95% RH
Vibration, shock and freefall IEC68-2-6, -27 and -32
Electrical safety
UL508 / CSA C22.2/14 (CUL), EN61010-1
EMC emissions and immunity FCC Part 15 / ICES-003; EN55022 / IEC61326-1
Hazardous locations ANSI / ISA12.12.01 / CSA C22.2/213 (CUL), Class 1, Division 2;
ATEX / IEC60079-0, -15 (Zone 2)
Eye safety (fiber models) IEC60825-1, Class 1; FDA 21
Mechanical DIN rail or direct to panel mounting
Packaging material & protection Polycarbonate with IP30 protection
Weight (approximate) 0.17 Kg (0.25 lbs)
Dimensions (H x W x D) (approximate) 4 x 1 x 3.3” (10 x 2.5 x 8.3 cm)
Etherbus Hardware Manual Page 19 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
MTBF (estimated) >1,000,000 hours
Etherbus Hardware Manual Page 20 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Etherbus Injector Performance Specifications
Model EB-PSE-24V-1 or EB-PSE-48V-2
General Industrial PoE Injectors
Ethernet protocols supported All IEEE 802.3
Ethernet connectors per channel 2 (1 for Ethernet in, 1 for PoE out)
Ethernet port standards 10/100BaseTX IEEE 802.3 / 802.3u
PoE Output Fully IEEE 802.2af compliant
IEEE 802.3af PoE operation Power Sourcing Equipment (PSE)
PoE power output 48 VDC @ 15.4 Watts per channel
(24V model only: derate 1W per 2°C after 60°C)
RJ45 PoE pin assignments (A=unused pair;
B=signal pair)
A: TX(3,6); RX(1,2); V-(7,8); V+(4,5)
B: TX/V- (3, 6); RX/V+ (1, 2)
PoE operation Auto-detection & power management
PoE disconnect mode AC on 24V-1 and DC on 48V-2
PoE protection Over-temp, over-current, over/under-voltage & transient
Power Input Fully IEEE 802.3af PoE compliant
Power input for 48V-2 models 45-56 VDC @ 31 Watts max.
Power input for 24V-1 models 18-30 VDC @ 20 Watts max.
PoE transient protection 15,000 watts peak
PoE spike protection 5,000 watts (10 times for 10 uS)
Environmental Truly industrial design
Operating temperature range -40 to +75 °C (cold startup @ -40) (see PoE power derating above)
Storage temperature range -40 to +85 °C
Humidity (non-condensing) 5 to 95% RH
Vibration, shock and freefall IEC68-2-6, -27 and -32
Electrical safety
UL508 / CSA C22.2/14 (CUL), EN61010-1
EMC emissions and immunity FCC Part 15 / ICES-003; EN55022 / IEC61326-1
Hazardous locations ANSI / ISA12.12.01 / CSA C22.2/213 (CUL), Class 1, Division 2;
ATEX / IEC60079-0, -15 (Zone 2)
Mechanical DIN rail or direct to panel mounting
Packaging material and protection Polycarbonate with IP30 protection
Weight (approximate) 0.17 Kg (0.25 lbs)
Dimensions (H x W x D) (approximate) 4 x 1 x 3.3” (10 x 2.5 x 8.3 cm)
MTBF (estimated) >1,000,000 hours
Etherbus Hardware Manual Page 21 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Etherbus Splitter Performance Specifications
Model EB-PD-24V-1
General Industrial PoE Splitter
Ethernet protocols supported All IEEE 802.3
Ethernet ports 2 (1 for PoE in, 1 for Ethernet out)
Ethernet port standards 10/100BaseTX IEEE 802.3 / 802.3u
PoE Input Fully IEEE 802.3af PoE compliant
IEEE 802.3af PoE operation Powered Device (PD)
PoE Power input range 45-56 VDC
PoE power input Automatic detection and classification (power is accepted on either
the signal or unused pairs)
PoE protection Over/under voltage lockout and inrush control
PoE transient protection 15,000 watts peak
PoE spike protection 5,000 watts (10 times for 10 uS)
Power Output Isolated power
Voltage output 24 VDC, 0.54 Amps (24V model)
14 VDC, 0.93 Amps (UPS model)
Power output 13 watts
Environmental Truly industrial design
Operating temperature range -40 to +75 °C (cold startup @ -40)
Storage temperature range -40 to +85 °C
Humidity (non-condensing) 5 to 95% RH
Vibration, shock and freefall IEC68-2-6, -27 and -32
Electrical safety
UL508 / CSA C22.2/14 (CUL), EN61010-1
EMC emissions and immunity FCC Part 15 / ICES-003; EN55022 / IEC61326-1
Hazardous locations ANSI / ISA12.12.01 / CSA C22.2/213 (CUL), Class 1, Division 2;
ATEX / IEC60079-0, -15 (Zone 2)
Mechanical DIN rail or direct to panel mounting
Packaging material and protection Polycarbonate with IP30 protection
Weight (approximate) 0.17 Kg (0.25 lbs)
Dimensions (H x W x D) (approximate) 4 x 1 x 3.3” (10 x 2.5 x 8.3 cm)
MTBF (estimated) >1,000,000 hours
Etherbus Hardware Manual Page 22 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Etherbus DC/DC Converter Performance Specifications Model EB-PS-4824-13
Output
DC voltage 24 VDC
Rated current 0.54 Amps
Current range 0 – 0.54 Amps
Rated power 13 Watts
Ripple / noise (max.) 200 mV p-p
Voltage tolerance +/- 1%
DC voltage range 45 – 56 VDC
Efficiency (typ.) 85 %
Current (typ.) 0.32 Amps @ 48 VDC
Protection
Over-load Current limiting with automatic recovery
Over-voltage Transient: 15Kw peak;
Surge: 5K watts (10x10 uS)
Over-temperature 140°C with auto. recovery
Environmental
Operation temp. -40 to + 75°C
Operation humidity 5 to 95% RH (non-cond.)
Storage -40 to + 85°C
Vibration, shock and freefall IEC68-2-6, -27 and -32
Standards
Safety
UL508 / CSA C22.2/14 (CUL); EN61010-1
Hazardous locations ANSI / ISA12.12.01 / CSA C22.2/213 (CUL), Class 1,
Division 2;
ATEX / IEC60079-0, -15 (Zone 2)
EMC emissions and immunity FCC Part 15 / ICES-003; EN55022 / IEC61326-1
Withstand voltage Input to output: 1500 Vrms
Miscellaneous
MTBF (estimated) >1,000,000 hours
Packaging Polycarbonate; IP30
Mounting DIN rail or flat to panel
Weight (approximate) 0.17 Kg (0.25 lbs)
Dims (w x h x d) (approximate) 25 x 101 x 76 mm (1.0 x 4.0 x 3.0 inches)
Etherbus Hardware Manual Page 23 of 23 Last Revised: 17-Sep-13 Red Lion Controls 331 Ushers Road Ballston Lake, NY 12019 USA +1-518-877-5173 [email protected]
Section 7 Service Information
Service
Information
We sincerely hope that you never experience a problem with any RED LION product. If you do
need service, call RED LION at 877-432-9908 and ask for Applications Engineering. A trained
specialist will help you to quickly determine the source of the problem. Many problems are
easily resolved with a single phone call. If it is necessary to return a unit to us, an RMA
(Return Material Authorization) number will be given to you.
RED LION tracks the flow of returned material with our RMA system to ensure speedy
service. You must include this RMA number on the outside of the box so that your return can
be processed immediately.
The applications engineer you are speaking with will fill out an RMA request for you. If the unit
has a serial number, we will not need detailed financial information. Otherwise, be sure to
have your original purchase order number and date purchased available.
We suggest that you give us a repair purchase order number in case the repair is not covered
under our warranty. You will not be billed if the repair is covered under warranty.
Please supply us with as many details about the problem as you can. The information you
supply will be written on the RMA form and supplied to the repair department before your unit
arrives. This helps us to provide you with the best service, in the fastest manner. Normally,
repairs are completed in two days. Sometimes difficult problems take a little longer to solve.
If you need a quicker turnaround, ship the unit to us by air freight. We give priority service to
equipment that arrives by overnight delivery. Many repairs received by mid-morning (typical
overnight delivery) can be finished the same day and returned immediately.
We apologize for any inconvenience that the need for repair may cause you. We hope that our
rapid service meets your needs. If you have any suggestions to help us improve our service,
please give us a call. We appreciate your ideas and will respond to them.
For Your Convenience:
Please fill in the following and keep this manual with your RED LION system for future
reference:
P.O. #:__________________ Date Purchased: ___________________
Purchased From:______________________________________________
Product
Support
To obtain support for RED LION products:
Latest product info: www.redlion.net
Phone: 1-877-432-9908
Fax: +1 (518) 877-8346
E-mail: [email protected]
Address: Red Lion Controls, 331 Ushers Road, Ballston Lake, NY 12019