INDUSTRIAL DRIVE: AINDUSTRIAL DRIVE: AINDUSTRIAL DRIVE: AINDUSTRIAL DRIVE: A CASE STUDY OF CHASSIS DRIVECASE STUDY OF CHASSIS DRIVECASE STUDY OF CHASSIS DRIVECASE STUDY OF CHASSIS DRIVE
EMPLOYEDEMPLOYEDEMPLOYEDEMPLOYED IN 6Hi SINGLE STAND REVERSINGIN 6Hi SINGLE STAND REVERSINGIN 6Hi SINGLE STAND REVERSINGIN 6Hi SINGLE STAND REVERSING
COLD ROLLINGCOLD ROLLINGCOLD ROLLINGCOLD ROLLING MILLMILLMILLMILL
BY
AKINYELE, DAMILOLA JOHNSON
BEING A TERM PAPER PRESENTED TO
THE DEPARTMENT OF ELECTRICAL AND ELECTRONIC ENGINEERING
FACULTY OF ENGINEERING,
UNIVERSITY OF LAGOS,
LAGOS, NIGERIA.
IN PARTIAL FULFILMENT OF THE REQUIREMENT
FOR THE AWARD OF MASTER OF SCIENCE (M.Sc) DEGREE IN
ELECTRICAL AND ELECTRONICS ENGINEERING (CONTROL OPTION)
MAY, 2011.
8/6/2019 Industrial Drive
2/23
1.0 ABSTRACT
This paper reviews the applications of electric drives in the industries, taking into consideration the
improving trend through the application of power electronics.
Application of a variable frequency drive (Chassis drive) employed in driving Rolling Mills Machinery at
Aluminum Rolling Mills (ARM), a subsidiary of Tower Aluminum Plc. Nigeria is briefly examined.
The examination includes analysis of the power circuit and control circuit with waveforms, Design of pow
circuit, selection of devices employed in the drive system and problems associated with the use of the d
in the Industry.
2.0 INTRODUCTION
Electric drive is an industrial system which performs the conversion of electrical energy to mech
energy or vice versa for running various processes. Drives are employed for systems that require m
control e.g. transportation system, fans, robots, pumps, machine tools, etc. Prime movers are requi
drive systems to provide the movement or motion and energy that is used to provide the motion can
from various sources: diesel engines, petrol engines, hydraulic motors, electric motors etc. Drives tha
electric motors as the prime movers are known as electrical drives
Figure 1:Block Diagram of Electric Drive
There are several advantages of electrical drives:
8/6/2019 Industrial Drive
3/23
a. Flexible control characteristic This is particularly true when power electronic converters are
employed where the dynamic and steady state characteristics of the motor can be controlled by contr
the applied voltage or current.
b. Available in wide range of speed, torque and power
c. High efficiency, lower noise, low maintenance requirements and cleaner operation
d. Electric energy is easy to be transported.
2.1 Components of Electrical Drives:
The main components of a modern electrical drive are the motors, power processor, control uni
electrical source.
a) Motors:
Motors obtain power from electrical sources. They convert energy from electrical to mechanical therefo
be regarded as energy converters. In braking mode, the flow of power is reversed. Depending upon the
of power converters used, it is also possible for the power to be fed back to the sources rather
dissipated as heat.
There are several types of motors used in electric drives choice of type used depends on applications,
environmental factors and also the type of sources available.
Broadly, they can be classified as either DC or AC motors:
DC motors (wound or permanent magnet)
AC motors:
Induction motors squirrel cage, wound rotor
Synchronous motors wound field, permanent magnet
Brushless DC motor require power electronic converters
Stepper motors require power electronic converters
Synchronous reluctance motors or switched reluctance motor require power electronic converters
b) Power processor or power modulator:
8/6/2019 Industrial Drive
4/23
Since the electrical sources are normally uncontrollable, it is therefore necessary to be able to contro
flow of power to the motor this is achieved using power processor or power modulator. With contro
sources, the motor can be reversed, brake or can be operated with variable speed. Conventional me
used, for example, variable impedance or relays, to shape the voltage or current that is supplied t
motor these methods however are inflexible and inefficient. Modern electric drives normally used
electronic converters to shape the desired voltage or current supplied to the motor. In other word
characteristic the characteristic of the motors can be changed at will. Power electronic converters
several advantages over classical methods of power conversion such as:
1. More efficient since ideally no losses occur in power electronic converters2. Flexible voltage and current can be shaped by simply controlling switching functions of the p
converter
3. Compact smaller, compact and higher ratings solidstate power electronic devices are continubeing developed the prices are getting cheaper.
Converters are used to convert and possibly regulate (i.e. using closed-loop control) the available sour
suit the load i.e. motors. These converters are efficient because the switches operate in either cut-
saturation modes
c) Control Unit:
8/6/2019 Industrial Drive
5/23
The complexity of the control unit depends on the desired drive performance and the type of motors us
controller can be as simple as few op-amps and/or a few digital ICs, or it canbe as complex a
combinations of several ASICs and digital signal processors (DSPs). The types of the main controlle
be:
1. analog - which is noisy, inflexible. However analog circuit ideally has infinite bandwidth.
2. digital immune to noise, configurable. The bandwidth is obviously smaller than the analog control
depends on sampling frequency
3. DSP/microprocessor flexible, lower bandwidth compared to above. DSPs perform faster operation
microprocessors (multiplication in single cycle).With DSP/microp, complex estimations and observers c
easily implemented.
d) Source
Electrical sources or power supplies provide the energy to the electrical motors. For high effic
operation, the power obtained from the electrical sources need to be regulated using power elec
converters.
Power sources can be of AC or DC in nature and normally are uncontrollable, i.e. their magnitud
frequencies are fixed or depend on the sources of energy such as solar or wind. AC source can be
three-phase or single-phase; 3-phase sources are normally for high power applications .There can be s
factors that affect the selection of different configuration of electrical drive system such as:
a) Torque and speed profile - determine the ratings of converters and the quadrant of operation require
b) Capital and running cost Drive systems will vary in terms of start-up cost and running cost
maintenance.
c) Space and weight restrictions
d) Environment and location
2.2 Comparison between DC and AC drives
Motors:
1. DC require maintenance, heavy, expensive, speed limited by mechanical construction
2. AC less maintenance, light, cheaper, robust, high speed (esp. squirrelcage type)
Control unit:
8/6/2019 Industrial Drive
6/23
1. DC drives: Simple control decoupling torque and flux by mechanical commutator the controller c
implemented using simple analog circuit even for high performance torque control cheaper.
2. AC drives, the types of controllers to be used depend on the required drive performance obviously
increases with performance. Scalar control drives technique does not require fast processor/DSP wher
FOC or DTC drives, DSPs or fast processors are normally employed.
Performance:
1. In DC motors, flux and torque components are always perpendicular to one another thanks tmechanical commutator and brushes. The torque is controlled via the armature current while maint
the field component constant. Fast torque and decouple control between flux and torque compo
can be achieved easily.
2.In AC machines, in particular the induction machines, magnetic coupling between phases and betstator and rotor windings makes the modeling and torque control difficult and complex. Control o
steady state operating conditions is accomplished by controlling the magnitude and the frequency
applied voltage; which is known as the scalar control technique. This is satisfactory in some applica
The transient states or the dynamics of the machine can only be controlled by applying the vector c
technique whereby the decoupling between the torque and flux components is achieved through
transformations. Implementation of this control technique is complex thus requires fast processors
as Digital Signal Processors (DSPs).
3.0 HISTORICAL BACKGROUND
3.0.1 Electrical drives in industry
Prior to the availability of electronics, clever electromechanical solutions involving combinations of dc an
machines (e.g., Krmer and Scherbius systems) were developed early in the 20th century to control
the speed of electric machines in industrial processes. The emergence of mature triggered-arc power sw
technology (e.g., grid-controlled mercury-arc rectifiers, thyratrons, ignitrons)
in the 1920s and 1930s provided a major boost to dc commutator machines as preferred prime movers
industrial drive application.
This situation persisted for several decades until solid-state thyristors finally provided the crucial power
switch breakthrough needed to build practical adjustable-frequency ac machine drives in the 1970s. Sin
that time, new generations of gate-controlled power switches have successively improved the performa
and cost-effectiveness of ac drives in comparison to their dc drive counterparts.
Although most of todays growth in the worldwide industrial drive market can be ascribed to ac drives,
modern generations of dc drives continue to hold a significant share of the total industrial drive market.
3.0.2 Induction motors
8/6/2019 Industrial Drive
7/23
The AC squirrel-cage induction motors are the largest group of all electrical drives in the industry
has been estimated that they are used in 70-80% of all industrial drive applications, especially in fixed-s
applications such as pump or fan drives. The benefits of induction motor are undisputable: simple
construction, low cost compared to other motors, simple maintenance, high efficiency and satisfactory
characteristics at the high speeds. With appropriate power electronics converters induction motors are u
in wide power range from kW to MW levels.
A common structure of induction motor is represented in Fig.1.4. Stator rotation field induces an
electromotive force in the short-circuited rotor winding. Due to the induced voltage and short-circuited
winding, current occurs in the rotor and electromagnetic torque is produced.
Induction motor was invented in the end of 19th century. Its theory is well-known and power
electronic converter technology provides appropriate variable-voltage/current, variable-frequency supply
efficient and stable variable-speed control. Thus, it is possible to obtain a dynamic performance in all
respects better than which could be obtained with a phase-controlled DC drive combination. The signific
characteristic of the induction motor is a slip caused by the rotor lagging the rotating stator magnetic fie
Rotor copper losses are directly proportional to the slip. For example, the rotor copper losses in
motor are approximately 4.7% of the nominal power if the efficiency of 85% is supposed. The slip has
impact when a high dynamic performance is needed, since it derates the transient response of the moto
The main disadvantage of the induction motor for the servo control systems is the nonlinear speed vers
torque and speed versus control voltage characteristics. Therefore such motors are inconvenient for the
implementation of the belt-drives.
Servo drives are applied for example in such areas of industry as:
Paper industry
Machine tools and metal working machinery Packaging machinery
Woodworking
In spite of the wide spread occurrence of electrical motors, the precision requirements for servo drives
constantly increase.
3.0.3 Common motor types in motion control
With invention of the motor the important question arisen is: how it can be controlled?
The first speed-controlled drive was introduced by Harry Ward Leonard and it required
three machines for scheme implementation. After the invention of transistor and rapid
development of electronics, new possibilities for accurate control of DC motor, such as
PWM technology, appeared. Brushless DC motors with permanent magnets were
introduced in early 1960s, but their power was limited due to not enough powerful PM
materials. Brushless DC motors for higher power application became available only after
the invention of PM materials with high energy density in the beginning of 1980s. Later
on, when the field-oriented control was introduced, it was possible to apply AC motors for speed-contro
applications. First speed-controlled AC drives were induction motors but in early 1990s the vector contro
8/6/2019 Industrial Drive
8/23
was also developed for PMSMs. Also, with rapid development of computer science became accessible co
of stepper motors directly from microcontrollers. All these motor types are available for wide range of m
control applications.
3.1 CURRENT STATE OF THE DRIVE
This past decade has witnessed major advances in power electronics technology for both industrial and
traction drives. These advances have made it possible to significantly improve the electrical performanc
these systems while simultaneously reducing their size and weight and, perhaps most importantly, redu
their cost. Improvements in all of these key metrics are expected to continue during coming
years, with a few trends meriting special attention:
1) Modularization and Automated Manufacturing:
Improved packaging of the power electronics components and subsystems is expected to be one of the
most active development areas because of the significant cost reductions that are achievable by
modularizing the power electronics and automating its manufacturing. Major progress toward these
objectives can already be observed in many of the new industrial drive products with ratings
of 10 kW or less. Wider acceptance of power electronics in automotive applications during coming years
both for traction and accessory applicationswill likely provide a substantial boost for this trend by focu
the energies of the automotive industry on achieving these manufacturing economies.
2) Increasing Silicon Content:
As the cost of power switches and their driver circuitry continues to diminish, trends toward increasing t
proportion of active silicon- based power electronics in future drive products at the expense of passive
components (i.e., capacitors, inductors, transformers) is certain to continue. Particularly in industrialdrives, international trends toward tighter regulation of the input power quality of new products is expe
to motivate the wider introduction of active rectifier stages using additional power switches with less
dependence on special transformers and passive L-C filters. Direct ac/ac power converter topologies suc
the matrix converter are expected to appear in some new applications, although their
ability to broadly displace the dominant rectifier-inverter topology is very uncertain. Serious efforts are
way to use new high-voltage power switches in innovative configurations to eliminate the need for heav
and expensive transformers in future heavy-rail traction drives operating
directly from 25-kV ac catenary supplies.
3) Power Converter/Machine Integration:
The third notable technology trend, and perhaps the most controversial, is wider adoption of integrated
packaging of the power electronics and the electrical machine in the same mechanical
package. Several industrial drive manufacturers have introduced product offerings ( 10 kW) based on th
approach during recent years with limited initial market appeal, but anecdotal evidence indicates that
acceptance among skeptical customers is gradually improving. Automotive manufacturers are exploring
8/6/2019 Industrial Drive
9/23
approach as a long-term approach for modularizing the EV and HEV electric propulsion units while
simultaneously reducing EMI emissions by eliminating long interconnecting cables between the inverter
and machine. Significant technical hurdles associated with the ability of the power electronics to survive
heat and vibration of the harsh machine environments are, gradually being overcome, making the elec
motor concept increasingly attractive for many drive applications from both a technical and economic
standpoint.
3.2 APPLICATION OF POWER ELECTRONICS IN DRIVES
The power electronic converters are used to obtain an adjustable DC voltage applied to the armature of
motor. There are basically two types of converters normally employed in DC drives: (i) controlled rectif
switch mode converter.
(i) Controlled rectifier:
Controlled rectifier can be operated from a single phase or three phase input.
Output voltage contain low frequency ripple which may require a large inductor inserted in armature c
in order to reduce the armature current ripple. A large armature current ripple is undesirable since it m
reflected in speed response if the inertia of the motorload is not large enough. Controlled rectifier has
bandwidth. The average output voltage response to a control signal, which is the delay angle, is rela
slow. Therefore cont rolled rectifier is not suitable for drives requiring a fast response. Eg. servo applica
In terms of quadrant of operations, a single phase or a three phase rectifier is only capable of operat
first and fourth quadrants which is no suitable for drives requiring forward breaking mode. To be a
operate in all four quadrants, configurations using back to back rectifiers or contactors shown below m
employed.
Figure 2: Thyristor Configurations
8/6/2019 Industrial Drive
10/23
The thyristor d.c. drive remains an important speed-controlled industrial drive, especially where the h
maintenance cost associated with the d.c. motor brushes (c.f. induction motor) is tolerable. The cont
(thyristor) rectifier provides a low-impedance adjustable 'd.c.' voltage for the motor armature, th
providing speed control.
3.2.1THYRISTOR D.C. DRIVES GENERAL
For motors up to a few kilowatts the armature converter can be supplied from either single-phase or t
phase mains, but for larger motors three-phase is always used. A separate thyristor or diode rectifier is
to supply the field of the motor: the power is much less than the armature power, so the supply is
single-phase, as shown in Figure 3(a). The arrangement shown in Figure 3(a) is typical of the majo
d.c. drives and provides for closed-loop speed control.
Figure 3(a) D.C Drive
Figure 3(b):Basic three-phase voltage-source inverter bridge.
8/6/2019 Industrial Drive
11/23
The main power circuit consists of a six-thyristor bridge circuit which rectifies the incoming a.c. sup
produce a d.c. supply to the motor armature. The assembly of thyristors, mounted on a heatsink, is u
referred to as the 'stack'. By altering the firing angle of the thyristors the mean value of the rectified vo
can be varied, thereby allowing the motor speed to be controlled.
The controlled rectifier produces a crude form of d.c. with a pronounced ripple in the output voltage
ripple component gives rise to pulsating currents and fluxes in the motor, and in order to avoid exc
eddy-current losses and commutation problems, the poles and frame should be of laminated constructio
It is accepted practice for motors supplied for use with thyristor drives to have laminated construction
older motors often have solid poles and/or frames, and these will not always work satisfactorily w
rectifier supply. It is also the norm for drive motors to be supplied with an attached 'blower' mo
standard. This provides continuous through ventilation and allows the motor to operate continuously
torque even down to the lowest speeds without overheating.
Low power control circuits are used to monitor the principal variables of interest (usually motor curren
speed), and to generate appropriate firing pulses so that the motor maintains constant speed d
variations in the load. The 'speed reference' (Figure 1) is typically an analogue voltage varying from 0
V, and obtained from a manual speed-setting potentiometer or from elsewhere in the plant.
The combination of power, control, and protective circuits constitutes the converter. Standard mo
converters are available as off-the-shelf items in sizes from 0.5 kW up to several hundred kW, while
drives will be tailored to individual requirements. Individual converters may be mounted in enclosure
isolators, fuses etc., or groups of converters may be mounted together to form a multi-motor drive.
8/6/2019 Industrial Drive
12/23
4.0 APPLICATION OF DRIVES IN ALUMINIUM ROLLING MILLS(ARM).
Set up in 1983, Aluminium Rolling Mils was a major step in backward integration for Tower Aluminium.
Aluminium Rolling Mills ( ARM) is today one of the largest Rolling Mills in West Africa, with facilities for
converting its basic raw material, aluminium ingots, into high quality coils & discs. The present installed
capacity is 12,000 tons / annum.
PRODUCT RANGE
Plain Coils
Thickness 0.43 to 1.2 mm Used in roofing sheets. Thickness 1.2 mm upto 2 mm Used for cash boxes, port cabins, pick up van bodies, metal
furniture.
Stucco Coils
Thickness 0.43 to 1.2 mm Used in channels, gutters, roofing.
Circles ( Discs )
Used for aluminium kitchenware.
Special coils
Used for high security registration plates for vehicles.
4.1 Roll Milling Machine
Steel rolling mill machinery is used for making or shaping the metal. This machinery is very helpful in
making or giving shape to the metals or steel. This steel rolling mill machinery varies on the basis of pro
This machinery is mostly used in steel and metal factories. This machinery is proving its worth in mecha
industry. The unit which uses this steel rolling mill machinery is known as steel rolling mill plants. Steel
rolled in steel rolling mill plants. Following type of items are rolled in steel rolling mill machinery plants:
Simple rounds, Steel rods, Wire rod in coils, Plates, Hot strips, H-beams, I-beams. Steel rolling mill
machinery is categorized in two ways that is hot rolling mill machinery and cold rolling mill machinery.
Hot rolling mill machinery- if the temperature of the metal is marked above its recrystallization tempera
then the metal is rolled into hot rolling mill machinery.
8/6/2019 Industrial Drive
13/23
Cold rolling mil machinery- if the temperature of the metal is marked below the recrystallisation temper
then the metal is rolled into cold rolling mill machinery. These procedures are carried out to harden the
metal according to the requirements of different companies.
The Chassis driveis one of the drives used in controlling the speed of the gears of the steel rolling mi
machines. This drive will be chosen for detailing in this paper.
4.2 Chassis drive
Squirrel-cage induction machines dominate ac industrial drive applications around the world for both ne
and retrofit applications. Permanent magnet (PM) synchronous machines are increasingly popular choic
high-performance servo applications because of their high power density. However, these represent on
small fraction of the total number of industrial drive applications, the majority of which (i.e., pumps, fan
can be satisfied with general-purpose induction motor drives using constant volts-per-hertz control.
Other types of brushless machines including switched reluctance account for only a small fraction of ne
industrial drive applications. Three-phase voltage source inverters using the basic six-switch bridge topo
shown in Fig. 3(b) have become the overwhelming favorite for industrial drive applications less than 2 M
During the past decade, IGBTs packaged in compact plastic power modules have rapidly expanded thei
voltage and current ratings so that they now dominate nearly all of the new industrial drive inverter des
Power modules are now available from several manufacturers with 1200-V IGBTs (appropriate for 460-V
machines) that are packaged either as single-switches (2400 A), dual-switch phase legs (800 A), or com
six-switch bridges ( 400 A), depending on the required current ratings. Continuing improvements in IGB
switching characteristics allow these devices to be used with PWM switching frequencies that range from
to 2 kHz in high-power drives ( 1 MW) to more than 20 kHz in lower power ratings ( 30 kW). IGBT pow
modules are being offered with gate drives and protective functions built into the same package. Anothemark of progress is the growing availability of integrated power modules (IPMs) that provide all of the p
semiconductors for a complete industrial drive in a single package, including IGBTs and diodes for the
rectifier, inverter, and brake stages described in the following section.
These integrated modules are already being produced with ratings of 1200 V and 50 A, with higher curr
ratings now in development.
8/6/2019 Industrial Drive
14/23
5.0 POWER CIRCUIT AND WAVEFORM
Figure 4: Power Circuit of a Chassis drive
5.1 WAVEFORMS
8/6/2019 Industrial Drive
15/23
Figure 5: (a) Stator current waveform (b) Stator voltage and current
The power waveform of the motor is as shown above using a computer based monitor.
6.0 DESIGN OF THE POWER CIRCUITSThe architecture for a typical panel-mounted chassis drive in the 50-kW power range is illustrated in Fig
The core of the power circuitry for this drive consists of an input three-phase diode rectifier, a precharg
circuit, dc link capacitor bank, and IGBT inverter stage. Other power components shown in this figure
including the input line ac reactor, input electromagnetic interference (EMI) filter, dc link reactor, dynam
brake, and output filter are all optional depending on the application requirements.
1) Inverter Stage:Modern IGBTs have matured to a high state of electrical ruggedness that makes it possible to design th
inverter stages with a minimum of additional snubber circuitry to limit either the rate of current change
di/dt) or the rate of voltage change (dv/dt ) at the IGBT terminals. In fact, many new IGBT inverters ar
designed without any snubbers at all. This approach has the advantage of saving cost, space, and losse
the inverterall positive effects. However, the resulting switching rates at the IGBT output terminals in
snubberless inverter designs can sometimes exceed 1000 A s and 10 000 V s, which is undesired and, i
some cases, harmful consequences. For example, it has been confirmed that the high switching rates ca
interact with the inverter output cables and the machine windings to cause large transient voltages to a
across the outermost turns of the stator windings. Field experience has demonstrated that this situation
sometimes leads to catastrophic failure of the stator winding insulation. Such conditions are most likely
occur in installations with unusually long cables between the drive inverter and machine. Some machine
manufacturers have responded by strengthening the stator winding insulation, at least for the outermos
turns.
It was also found that the high switching rates can induce unbalanced charge build-ups on the machine
by means of parasitic capacitances coupling the machine stator, the rotor, inverter switches, and ground
8/6/2019 Industrial Drive
16/23
This accumulated rotor charge eventually discharges through the bearings if no other galvanic current p
is provided. Over time, these discharges
can cause serious pitting of the bearing balls and races that eventually leads to bearing failures under s
circumstances that have been experienced in field installations. The introduction of insulated bearings o
grounded rotor shaft brushes is among the solutions adopted by machine manufacturers to prevent the
bearing failures.
A third problem caused by the high and switching rates is elevated levels of conducted EMI in
the drive input lines and ground that can easily exceed acceptable levels. Common-mode EMI can be
significantly reduced by adding common-mode inductors in both the input and output lines, together wi
small capacitors between each dc link bus and earth ground to prevent these high-frequency currents fr
reaching the utility grid or machine. Modifications of the PWM switching algorithm can also be introduce
minimize the generation of common-mode EMI. Differential-mode EMI can be reduced by adding passiv
active filters on the inverter output lines. Another effective, albeit somewhat ironic solution to these EM
problems is to use the IGBT gate drives to artificially slow their switching speeds, trading reduced EMI f
elevated switching losses.
2) Input Rectifier Stage:By showing a diode rectifier stage in Fig. 4, the illustrated architecture is typical of the
large majority of todays industrial drives ( 90%) that do not permit braking power to be returned to the
utility lines. Although the diode rectifier has the advantage of low cost, it also imposes several constrain
and disadvantages on the drive system that are attracting more attention every year.
Perhaps most importantly, the basic diode rectifier draws current from each input line that is significant
distorted from its desired sinusoidal shape [Fig. 6(a)].One of the purposes of including either a dc link reactor or three-phase input line reactors in the drive p
circuitry is to reduce the amplitude of the input current harmonics in addition to limiting the peak dc lin
capacitor current and reducing the conducted EMI. However, Fig. 6(b) shows that, even when the ac lin
reactors are introduced with typical ratings (3% of the drive base impedance, in this case), the input lin
current harmonics are still very substantial, containing a fifth harmonic component greater than 40% of
fundamental component. Another constraint imposed by diode rectifiers is the need for pre-charging of
dc link capacitors to avoid dangerous surge current when the drive is initially connected to the ac line. A
variety of pre-charge circuits are used depending on the drive power rating, including the parallel
combination of resistor and bypass contactor illustrated in Fig. 4.
For industrial drives with ratings greater than 30 kW, the diodes in the input rectifier stage are often pa
or completely replaced by phase-controlled thyristors. Although more expensive than the diodes, the
thyristors serve multiple purposes by providing the pre-charge function and serving as a fast electronic
circuit breaker to remove power from the dc link in case of ground-fault or inverter failures.
Many industrial drive applications that demand only limited and infrequent machine braking capability (e
conveyors) can be satisfied by means of a dynamic brake assembly that dissipates the excess electrical
8/6/2019 Industrial Drive
17/23
energy appearing on the dc link in external resistors (see Fig. 4). However, applications that involve freq
and extended periods of
braking (e.g., cranes) can justify the introduction of a regenerative input converter bridge as shown in F
to provide the drive with bidirectional power conversion capabilities.
The topology of the input converter bridge is identical to that of the inverter using six controlled switche
(i.e., IGBTs) and six diodes, as shown previously in Fig. 3. Three-phase input line reactors are essential
the active input bridge configuration to provide the necessary input impedance characteristics to the br
terminals.
The addition of the regenerative active input bridge clearly represents an expensive solution that can on
justified today in applications that truly need bidirectional power flow.
However, appropriate PWM control of the active input bridge results in significant system advantages by
eliminating all of the undesirable low-order current harmonics that are associated
with either diode or thyristor bridges, as well as providing independent control of the input power factor
7 shows typical input line and dc link voltage/current waveforms for a regenerative drive system, illustra
the major improvement in line current harmonics compared to the diode rectifier waveform shown earli
Fig. 6. This figure also illustrates the fast response that regenerative input stages can provide using vec
control principles handling a step change in drive operation from full-load motoring to full-load braking w
minimal perturbations of the dc link voltage.
3) Bus Capacitors:Electrolytic capacitors are the preferred choice for the dc link capacitors in almost
industrial drives. Minimum dc link capacitance requirements are usually determined by the rms current-
carrying capacity of the electrolytic capacitors and the need for sufficient dc link energy storage to allowdrive to ride through transient utility voltage sags. Typical electrolytic capacitor bank values for gener
purpose drives fall between 25 and 50 F per amp of inverter rms output current. Since the voltage ratin
electrolytic capacitors are usually limited to 500 Vdc or less, series and parallel combinations are require
many drive applications to support dc link voltages that exceed these ratings.
Newer film capacitors are available with higher rms current ratings per F of capacitance and better relia
characteristics than their electrolytic counterparts. However, film capacitors are seldom used in place of
electrolytics today because they are more expensive and smaller bus capacitance provides less drive rid
through protection during utility voltage sag events.
8/6/2019 Industrial Drive
18/23
7.0 CONTROL CIRCUIT WITH WAVEFORMS
Fig. 6. Three-phase diode rectifier characteristics. (a) Input voltage and current
waveforms. (b) Input current frequency spectrum.
Figure 7: Block diagram of IGBT controlled drive of a 6Hi Cold Rolling Mill motors
8.0 DESIGN OF THE CONTROL CIRCUIT
The input voltage directly sets the oscillator and hence the inverter frequency. The input setting also
determines the link voltage, so maintaining the voltage/frequency relationship. In order to march the m
speed with the increasing frequency, the frequency must start from zero and rise at a rate such that the
torque can accelerate the rotor to this rate.
The ramp unit delays the rise of voltage resulting from any step input, and allows the inverter
frequency to rise slowly, so maintaining stability during the accelerating period.
The accuracy of the drive depends on the oscillator frequency.The DC link voltage adjustment
controls the motor voltage magnitude and frequency within the inverter can be controlled.
8/6/2019 Industrial Drive
19/23
The use of insulated gate bipolar transistors enables switching within the inverter to be faster an
more efficient than thyristor circuit.
Figure 8 : Diode-IGBT current switching characteristics for one inverter-leg, according to Martin (1996).
refers to the upper and T to the lower transistor and+ is the freewheeling diode of the upper transisto
9.0 APPLICATION IN THE LOCAL INDUSTRY WITH DIAGRAM
The Chassis drive is used for controlling the speed, torque, voltage and current of the 6Hi Cold Rolling M
motors.
The aim is to reduce the thickness of hot rolled coil.
Also, the drive is used for controlling the uncoiler motor, the edge trimmer, motor, and the recoiler mot
shown below:
Figure 9: Block Diagram of Cold Rolling Mill Machine
8/6/2019 Industrial Drive
20/23
Figure 10: 6Hi Cold Rolling Mill Machine
Figure 10(a) and (b) : Production Line pictures.
8/6/2019 Industrial Drive
21/23
10.0 SELECTION OF DEVICES OF THE DESIGN SYSTEMS
The devices used are:
(a) Insulated Gate Bipolar Transistor based inverter
(b) Converter transformer
(c) Thyristor supply unit for conversion
(d) Motor
(e) Air Circuit Breakers (ACB)
(f) Moulded Case Circuit Breakers (MCCB)
(g) Contactor
(h) Relays
(i) Indicator Lamp
(j) Fuse
(k) Encoder
11.0 PROBLEMS ASSOCIATED WITH THE USE OF THE DRIVE IN THE INDUSTRY
1. The drive discussed above is a variable frequency drive, hence the introduction of harmonic
Pollution by non-linear elements in the make up of the drive is a challenge the industries
Face with the application of the drive.
2. The resulting switching rates at the IGBT output terminals in snubberless inverter designs
Employed in the drive can sometimes exceed 1000 A s and 10 000 V s, which is undesired and, in
some cases, harmful.3. This high switching rates can induce unbalanced charge build-ups on the machine rotor by means o
parasitic capacitances coupling the machine stator, the rotor, inverter switches, and ground. This
accumulated rotor charge eventually discharges through the bearings if no other galvanic current pa
provided. Over time, these discharges can cause serious pitting of the bearing balls and races that
eventually leads to bearing failures under so circumstances that have been experienced in field insta
tions
4. Erratic power supply from the supply authority can cause huge damage during manufacturing
12.0 RECOMMENDATION
The stator winding insulation should be strengthened, at least the outer most insulation. Necessary filter circuit should be introduced to reduced the effect of harmonics. Insulated bearings or grounded rotors should be Incorporated to reduce the effect of
bearing failure in the applications of the drive.
Technology transfer method should be adopted to develop our local industry. Research and development of drives that suit the local industry should be vigorously pursue
8/6/2019 Industrial Drive
22/23
13.0 CONCLUSIONS
Drives are important in every manufacturing industry as they provide means of adjusting torque, spe
voltage, current as regards to a given motor leading to reduction in the electrical energy demand of a
system and industry at large.
Local manufacture of drives will go a long way to developing our local technology as well as human
resources.
REFERENCES
[1] Ashfaq Amhed, Power Electronics for Technology, Prentice Hall, New Jersey, 1999.
[2] J.A. Odunsi, Electrical Installation, Design and Drafting, Yabatech Press, Lagos, 2000.
[3] Cyril W. Lander, Power Electronics, McGRAW-HILL Book Company, England, 1993.
[4] Katsuhiko Ogata, Modern Control Engineering, Prentice Hall, India, 2009.
[5] O.D. Osunde, Bridgeless Asymmetrical Single Phase AC-DC Boost Converter for Power
Factor Correction, Proceedings of the 3rd International Conference on Power Systems and
Telecommunications, UNILAG, July 22nd-24th, 2009, pp52-55.
[6] J.M.D. Murphy and F.G. Turnbull, Power Electronic Control of AC Motors, Pergamon Press,
New York, 1988.
[7] www.ABB.com(downloaded 25th April, 2010).
[8] T. M. Jahns and E. L. Owen, AC adjustable-speed drives at the new millennium:
Howdid we get here?, in Proc. 2000 IEEE Appl. Power Elec. Conf., New Orleans, LA,
Feb. 2000, pp. 1826.
[9] D. P. J. Link, Minimizing electric gearing currents in SSD systems,IEEE Ind. Appl. Mag.,pp. 5566, July/Aug. 1999.
[10] S. Bhattacharya, L. Resta, D. M. Divan, and D.W. Novotny, Experimental comparison
of motor bearing currents with PWM hard- and soft-switched voltage-source
inverters,IEEE Trans. Power Electron., vol. 14, pp. 552562, May 1999.
[11] M. Cacciato, A. Consoli, G. Scarcella, and A. Testa, Reduction ofcommon-mode currents
in PWMinverter motor drives,IEEE Trans.Ind. Applicat., vol. 35, pp. 469477,
Mar./Apr. 1999.
[12] G. Oriti, A. Julian, and T. Lipo, Elimination of common mode voltage in three
phase sinusoidal power converters, in Proc. IEEEPower Elec. Spec. Conf., Baveno,
Italy, June 1996, pp. 19681972.
8/6/2019 Industrial Drive
23/23
INDUSTRIAL DRIVE: AINDUSTRIAL DRIVE: AINDUSTRIAL DRIVE: AINDUSTRIAL DRIVE: A CASE STUDY OF CHASSIS DRIVECASE STUDY OF CHASSIS DRIVECASE STUDY OF CHASSIS DRIVECASE STUDY OF CHASSIS DRIVE
EMPLOYEDEMPLOYEDEMPLOYEDEMPLOYED IN 6Hi SINGLE STAND REVERSINGIN 6Hi SINGLE STAND REVERSINGIN 6Hi SINGLE STAND REVERSINGIN 6Hi SINGLE STAND REVERSING
COLD ROLLINGCOLD ROLLINGCOLD ROLLINGCOLD ROLLING MILLMILLMILLMILL
BY
AKINYELE, DAMILOLA JOHNSON
BEING A TERM PAPER PRESENTED TO
THE DEPARTMENT OF ELECTRICAL AND ELECTRONIC ENGINEERING
FACULTY OF ENGINEERING,
UNIVERSITY OF LAGOS,
LAGOS, NIGERIA.
IN PARTIAL FULFILMENT OF THE REQUIREMENT
FOR THE AWARD OF MASTER OF SCIENCE (M.Sc) DEGREE IN
ELECTRICAL AND ELECTRONICS ENGINEERING (CONTROL OPTION)
MAY, 2011.