Industrial Drive

Embed Size (px)

Citation preview

  • 8/6/2019 Industrial Drive

    1/23

    INDUSTRIAL DRIVE: AINDUSTRIAL DRIVE: AINDUSTRIAL DRIVE: AINDUSTRIAL DRIVE: A CASE STUDY OF CHASSIS DRIVECASE STUDY OF CHASSIS DRIVECASE STUDY OF CHASSIS DRIVECASE STUDY OF CHASSIS DRIVE

    EMPLOYEDEMPLOYEDEMPLOYEDEMPLOYED IN 6Hi SINGLE STAND REVERSINGIN 6Hi SINGLE STAND REVERSINGIN 6Hi SINGLE STAND REVERSINGIN 6Hi SINGLE STAND REVERSING

    COLD ROLLINGCOLD ROLLINGCOLD ROLLINGCOLD ROLLING MILLMILLMILLMILL

    BY

    AKINYELE, DAMILOLA JOHNSON

    [email protected]

    BEING A TERM PAPER PRESENTED TO

    THE DEPARTMENT OF ELECTRICAL AND ELECTRONIC ENGINEERING

    FACULTY OF ENGINEERING,

    UNIVERSITY OF LAGOS,

    LAGOS, NIGERIA.

    IN PARTIAL FULFILMENT OF THE REQUIREMENT

    FOR THE AWARD OF MASTER OF SCIENCE (M.Sc) DEGREE IN

    ELECTRICAL AND ELECTRONICS ENGINEERING (CONTROL OPTION)

    MAY, 2011.

  • 8/6/2019 Industrial Drive

    2/23

    1.0 ABSTRACT

    This paper reviews the applications of electric drives in the industries, taking into consideration the

    improving trend through the application of power electronics.

    Application of a variable frequency drive (Chassis drive) employed in driving Rolling Mills Machinery at

    Aluminum Rolling Mills (ARM), a subsidiary of Tower Aluminum Plc. Nigeria is briefly examined.

    The examination includes analysis of the power circuit and control circuit with waveforms, Design of pow

    circuit, selection of devices employed in the drive system and problems associated with the use of the d

    in the Industry.

    2.0 INTRODUCTION

    Electric drive is an industrial system which performs the conversion of electrical energy to mech

    energy or vice versa for running various processes. Drives are employed for systems that require m

    control e.g. transportation system, fans, robots, pumps, machine tools, etc. Prime movers are requi

    drive systems to provide the movement or motion and energy that is used to provide the motion can

    from various sources: diesel engines, petrol engines, hydraulic motors, electric motors etc. Drives tha

    electric motors as the prime movers are known as electrical drives

    Figure 1:Block Diagram of Electric Drive

    There are several advantages of electrical drives:

  • 8/6/2019 Industrial Drive

    3/23

    a. Flexible control characteristic This is particularly true when power electronic converters are

    employed where the dynamic and steady state characteristics of the motor can be controlled by contr

    the applied voltage or current.

    b. Available in wide range of speed, torque and power

    c. High efficiency, lower noise, low maintenance requirements and cleaner operation

    d. Electric energy is easy to be transported.

    2.1 Components of Electrical Drives:

    The main components of a modern electrical drive are the motors, power processor, control uni

    electrical source.

    a) Motors:

    Motors obtain power from electrical sources. They convert energy from electrical to mechanical therefo

    be regarded as energy converters. In braking mode, the flow of power is reversed. Depending upon the

    of power converters used, it is also possible for the power to be fed back to the sources rather

    dissipated as heat.

    There are several types of motors used in electric drives choice of type used depends on applications,

    environmental factors and also the type of sources available.

    Broadly, they can be classified as either DC or AC motors:

    DC motors (wound or permanent magnet)

    AC motors:

    Induction motors squirrel cage, wound rotor

    Synchronous motors wound field, permanent magnet

    Brushless DC motor require power electronic converters

    Stepper motors require power electronic converters

    Synchronous reluctance motors or switched reluctance motor require power electronic converters

    b) Power processor or power modulator:

  • 8/6/2019 Industrial Drive

    4/23

    Since the electrical sources are normally uncontrollable, it is therefore necessary to be able to contro

    flow of power to the motor this is achieved using power processor or power modulator. With contro

    sources, the motor can be reversed, brake or can be operated with variable speed. Conventional me

    used, for example, variable impedance or relays, to shape the voltage or current that is supplied t

    motor these methods however are inflexible and inefficient. Modern electric drives normally used

    electronic converters to shape the desired voltage or current supplied to the motor. In other word

    characteristic the characteristic of the motors can be changed at will. Power electronic converters

    several advantages over classical methods of power conversion such as:

    1. More efficient since ideally no losses occur in power electronic converters2. Flexible voltage and current can be shaped by simply controlling switching functions of the p

    converter

    3. Compact smaller, compact and higher ratings solidstate power electronic devices are continubeing developed the prices are getting cheaper.

    Converters are used to convert and possibly regulate (i.e. using closed-loop control) the available sour

    suit the load i.e. motors. These converters are efficient because the switches operate in either cut-

    saturation modes

    c) Control Unit:

  • 8/6/2019 Industrial Drive

    5/23

    The complexity of the control unit depends on the desired drive performance and the type of motors us

    controller can be as simple as few op-amps and/or a few digital ICs, or it canbe as complex a

    combinations of several ASICs and digital signal processors (DSPs). The types of the main controlle

    be:

    1. analog - which is noisy, inflexible. However analog circuit ideally has infinite bandwidth.

    2. digital immune to noise, configurable. The bandwidth is obviously smaller than the analog control

    depends on sampling frequency

    3. DSP/microprocessor flexible, lower bandwidth compared to above. DSPs perform faster operation

    microprocessors (multiplication in single cycle).With DSP/microp, complex estimations and observers c

    easily implemented.

    d) Source

    Electrical sources or power supplies provide the energy to the electrical motors. For high effic

    operation, the power obtained from the electrical sources need to be regulated using power elec

    converters.

    Power sources can be of AC or DC in nature and normally are uncontrollable, i.e. their magnitud

    frequencies are fixed or depend on the sources of energy such as solar or wind. AC source can be

    three-phase or single-phase; 3-phase sources are normally for high power applications .There can be s

    factors that affect the selection of different configuration of electrical drive system such as:

    a) Torque and speed profile - determine the ratings of converters and the quadrant of operation require

    b) Capital and running cost Drive systems will vary in terms of start-up cost and running cost

    maintenance.

    c) Space and weight restrictions

    d) Environment and location

    2.2 Comparison between DC and AC drives

    Motors:

    1. DC require maintenance, heavy, expensive, speed limited by mechanical construction

    2. AC less maintenance, light, cheaper, robust, high speed (esp. squirrelcage type)

    Control unit:

  • 8/6/2019 Industrial Drive

    6/23

    1. DC drives: Simple control decoupling torque and flux by mechanical commutator the controller c

    implemented using simple analog circuit even for high performance torque control cheaper.

    2. AC drives, the types of controllers to be used depend on the required drive performance obviously

    increases with performance. Scalar control drives technique does not require fast processor/DSP wher

    FOC or DTC drives, DSPs or fast processors are normally employed.

    Performance:

    1. In DC motors, flux and torque components are always perpendicular to one another thanks tmechanical commutator and brushes. The torque is controlled via the armature current while maint

    the field component constant. Fast torque and decouple control between flux and torque compo

    can be achieved easily.

    2.In AC machines, in particular the induction machines, magnetic coupling between phases and betstator and rotor windings makes the modeling and torque control difficult and complex. Control o

    steady state operating conditions is accomplished by controlling the magnitude and the frequency

    applied voltage; which is known as the scalar control technique. This is satisfactory in some applica

    The transient states or the dynamics of the machine can only be controlled by applying the vector c

    technique whereby the decoupling between the torque and flux components is achieved through

    transformations. Implementation of this control technique is complex thus requires fast processors

    as Digital Signal Processors (DSPs).

    3.0 HISTORICAL BACKGROUND

    3.0.1 Electrical drives in industry

    Prior to the availability of electronics, clever electromechanical solutions involving combinations of dc an

    machines (e.g., Krmer and Scherbius systems) were developed early in the 20th century to control

    the speed of electric machines in industrial processes. The emergence of mature triggered-arc power sw

    technology (e.g., grid-controlled mercury-arc rectifiers, thyratrons, ignitrons)

    in the 1920s and 1930s provided a major boost to dc commutator machines as preferred prime movers

    industrial drive application.

    This situation persisted for several decades until solid-state thyristors finally provided the crucial power

    switch breakthrough needed to build practical adjustable-frequency ac machine drives in the 1970s. Sin

    that time, new generations of gate-controlled power switches have successively improved the performa

    and cost-effectiveness of ac drives in comparison to their dc drive counterparts.

    Although most of todays growth in the worldwide industrial drive market can be ascribed to ac drives,

    modern generations of dc drives continue to hold a significant share of the total industrial drive market.

    3.0.2 Induction motors

  • 8/6/2019 Industrial Drive

    7/23

    The AC squirrel-cage induction motors are the largest group of all electrical drives in the industry

    has been estimated that they are used in 70-80% of all industrial drive applications, especially in fixed-s

    applications such as pump or fan drives. The benefits of induction motor are undisputable: simple

    construction, low cost compared to other motors, simple maintenance, high efficiency and satisfactory

    characteristics at the high speeds. With appropriate power electronics converters induction motors are u

    in wide power range from kW to MW levels.

    A common structure of induction motor is represented in Fig.1.4. Stator rotation field induces an

    electromotive force in the short-circuited rotor winding. Due to the induced voltage and short-circuited

    winding, current occurs in the rotor and electromagnetic torque is produced.

    Induction motor was invented in the end of 19th century. Its theory is well-known and power

    electronic converter technology provides appropriate variable-voltage/current, variable-frequency supply

    efficient and stable variable-speed control. Thus, it is possible to obtain a dynamic performance in all

    respects better than which could be obtained with a phase-controlled DC drive combination. The signific

    characteristic of the induction motor is a slip caused by the rotor lagging the rotating stator magnetic fie

    Rotor copper losses are directly proportional to the slip. For example, the rotor copper losses in

    motor are approximately 4.7% of the nominal power if the efficiency of 85% is supposed. The slip has

    impact when a high dynamic performance is needed, since it derates the transient response of the moto

    The main disadvantage of the induction motor for the servo control systems is the nonlinear speed vers

    torque and speed versus control voltage characteristics. Therefore such motors are inconvenient for the

    implementation of the belt-drives.

    Servo drives are applied for example in such areas of industry as:

    Paper industry

    Machine tools and metal working machinery Packaging machinery

    Woodworking

    In spite of the wide spread occurrence of electrical motors, the precision requirements for servo drives

    constantly increase.

    3.0.3 Common motor types in motion control

    With invention of the motor the important question arisen is: how it can be controlled?

    The first speed-controlled drive was introduced by Harry Ward Leonard and it required

    three machines for scheme implementation. After the invention of transistor and rapid

    development of electronics, new possibilities for accurate control of DC motor, such as

    PWM technology, appeared. Brushless DC motors with permanent magnets were

    introduced in early 1960s, but their power was limited due to not enough powerful PM

    materials. Brushless DC motors for higher power application became available only after

    the invention of PM materials with high energy density in the beginning of 1980s. Later

    on, when the field-oriented control was introduced, it was possible to apply AC motors for speed-contro

    applications. First speed-controlled AC drives were induction motors but in early 1990s the vector contro

  • 8/6/2019 Industrial Drive

    8/23

    was also developed for PMSMs. Also, with rapid development of computer science became accessible co

    of stepper motors directly from microcontrollers. All these motor types are available for wide range of m

    control applications.

    3.1 CURRENT STATE OF THE DRIVE

    This past decade has witnessed major advances in power electronics technology for both industrial and

    traction drives. These advances have made it possible to significantly improve the electrical performanc

    these systems while simultaneously reducing their size and weight and, perhaps most importantly, redu

    their cost. Improvements in all of these key metrics are expected to continue during coming

    years, with a few trends meriting special attention:

    1) Modularization and Automated Manufacturing:

    Improved packaging of the power electronics components and subsystems is expected to be one of the

    most active development areas because of the significant cost reductions that are achievable by

    modularizing the power electronics and automating its manufacturing. Major progress toward these

    objectives can already be observed in many of the new industrial drive products with ratings

    of 10 kW or less. Wider acceptance of power electronics in automotive applications during coming years

    both for traction and accessory applicationswill likely provide a substantial boost for this trend by focu

    the energies of the automotive industry on achieving these manufacturing economies.

    2) Increasing Silicon Content:

    As the cost of power switches and their driver circuitry continues to diminish, trends toward increasing t

    proportion of active silicon- based power electronics in future drive products at the expense of passive

    components (i.e., capacitors, inductors, transformers) is certain to continue. Particularly in industrialdrives, international trends toward tighter regulation of the input power quality of new products is expe

    to motivate the wider introduction of active rectifier stages using additional power switches with less

    dependence on special transformers and passive L-C filters. Direct ac/ac power converter topologies suc

    the matrix converter are expected to appear in some new applications, although their

    ability to broadly displace the dominant rectifier-inverter topology is very uncertain. Serious efforts are

    way to use new high-voltage power switches in innovative configurations to eliminate the need for heav

    and expensive transformers in future heavy-rail traction drives operating

    directly from 25-kV ac catenary supplies.

    3) Power Converter/Machine Integration:

    The third notable technology trend, and perhaps the most controversial, is wider adoption of integrated

    packaging of the power electronics and the electrical machine in the same mechanical

    package. Several industrial drive manufacturers have introduced product offerings ( 10 kW) based on th

    approach during recent years with limited initial market appeal, but anecdotal evidence indicates that

    acceptance among skeptical customers is gradually improving. Automotive manufacturers are exploring

  • 8/6/2019 Industrial Drive

    9/23

    approach as a long-term approach for modularizing the EV and HEV electric propulsion units while

    simultaneously reducing EMI emissions by eliminating long interconnecting cables between the inverter

    and machine. Significant technical hurdles associated with the ability of the power electronics to survive

    heat and vibration of the harsh machine environments are, gradually being overcome, making the elec

    motor concept increasingly attractive for many drive applications from both a technical and economic

    standpoint.

    3.2 APPLICATION OF POWER ELECTRONICS IN DRIVES

    The power electronic converters are used to obtain an adjustable DC voltage applied to the armature of

    motor. There are basically two types of converters normally employed in DC drives: (i) controlled rectif

    switch mode converter.

    (i) Controlled rectifier:

    Controlled rectifier can be operated from a single phase or three phase input.

    Output voltage contain low frequency ripple which may require a large inductor inserted in armature c

    in order to reduce the armature current ripple. A large armature current ripple is undesirable since it m

    reflected in speed response if the inertia of the motorload is not large enough. Controlled rectifier has

    bandwidth. The average output voltage response to a control signal, which is the delay angle, is rela

    slow. Therefore cont rolled rectifier is not suitable for drives requiring a fast response. Eg. servo applica

    In terms of quadrant of operations, a single phase or a three phase rectifier is only capable of operat

    first and fourth quadrants which is no suitable for drives requiring forward breaking mode. To be a

    operate in all four quadrants, configurations using back to back rectifiers or contactors shown below m

    employed.

    Figure 2: Thyristor Configurations

  • 8/6/2019 Industrial Drive

    10/23

    The thyristor d.c. drive remains an important speed-controlled industrial drive, especially where the h

    maintenance cost associated with the d.c. motor brushes (c.f. induction motor) is tolerable. The cont

    (thyristor) rectifier provides a low-impedance adjustable 'd.c.' voltage for the motor armature, th

    providing speed control.

    3.2.1THYRISTOR D.C. DRIVES GENERAL

    For motors up to a few kilowatts the armature converter can be supplied from either single-phase or t

    phase mains, but for larger motors three-phase is always used. A separate thyristor or diode rectifier is

    to supply the field of the motor: the power is much less than the armature power, so the supply is

    single-phase, as shown in Figure 3(a). The arrangement shown in Figure 3(a) is typical of the majo

    d.c. drives and provides for closed-loop speed control.

    Figure 3(a) D.C Drive

    Figure 3(b):Basic three-phase voltage-source inverter bridge.

  • 8/6/2019 Industrial Drive

    11/23

    The main power circuit consists of a six-thyristor bridge circuit which rectifies the incoming a.c. sup

    produce a d.c. supply to the motor armature. The assembly of thyristors, mounted on a heatsink, is u

    referred to as the 'stack'. By altering the firing angle of the thyristors the mean value of the rectified vo

    can be varied, thereby allowing the motor speed to be controlled.

    The controlled rectifier produces a crude form of d.c. with a pronounced ripple in the output voltage

    ripple component gives rise to pulsating currents and fluxes in the motor, and in order to avoid exc

    eddy-current losses and commutation problems, the poles and frame should be of laminated constructio

    It is accepted practice for motors supplied for use with thyristor drives to have laminated construction

    older motors often have solid poles and/or frames, and these will not always work satisfactorily w

    rectifier supply. It is also the norm for drive motors to be supplied with an attached 'blower' mo

    standard. This provides continuous through ventilation and allows the motor to operate continuously

    torque even down to the lowest speeds without overheating.

    Low power control circuits are used to monitor the principal variables of interest (usually motor curren

    speed), and to generate appropriate firing pulses so that the motor maintains constant speed d

    variations in the load. The 'speed reference' (Figure 1) is typically an analogue voltage varying from 0

    V, and obtained from a manual speed-setting potentiometer or from elsewhere in the plant.

    The combination of power, control, and protective circuits constitutes the converter. Standard mo

    converters are available as off-the-shelf items in sizes from 0.5 kW up to several hundred kW, while

    drives will be tailored to individual requirements. Individual converters may be mounted in enclosure

    isolators, fuses etc., or groups of converters may be mounted together to form a multi-motor drive.

  • 8/6/2019 Industrial Drive

    12/23

    4.0 APPLICATION OF DRIVES IN ALUMINIUM ROLLING MILLS(ARM).

    Set up in 1983, Aluminium Rolling Mils was a major step in backward integration for Tower Aluminium.

    Aluminium Rolling Mills ( ARM) is today one of the largest Rolling Mills in West Africa, with facilities for

    converting its basic raw material, aluminium ingots, into high quality coils & discs. The present installed

    capacity is 12,000 tons / annum.

    PRODUCT RANGE

    Plain Coils

    Thickness 0.43 to 1.2 mm Used in roofing sheets. Thickness 1.2 mm upto 2 mm Used for cash boxes, port cabins, pick up van bodies, metal

    furniture.

    Stucco Coils

    Thickness 0.43 to 1.2 mm Used in channels, gutters, roofing.

    Circles ( Discs )

    Used for aluminium kitchenware.

    Special coils

    Used for high security registration plates for vehicles.

    4.1 Roll Milling Machine

    Steel rolling mill machinery is used for making or shaping the metal. This machinery is very helpful in

    making or giving shape to the metals or steel. This steel rolling mill machinery varies on the basis of pro

    This machinery is mostly used in steel and metal factories. This machinery is proving its worth in mecha

    industry. The unit which uses this steel rolling mill machinery is known as steel rolling mill plants. Steel

    rolled in steel rolling mill plants. Following type of items are rolled in steel rolling mill machinery plants:

    Simple rounds, Steel rods, Wire rod in coils, Plates, Hot strips, H-beams, I-beams. Steel rolling mill

    machinery is categorized in two ways that is hot rolling mill machinery and cold rolling mill machinery.

    Hot rolling mill machinery- if the temperature of the metal is marked above its recrystallization tempera

    then the metal is rolled into hot rolling mill machinery.

  • 8/6/2019 Industrial Drive

    13/23

    Cold rolling mil machinery- if the temperature of the metal is marked below the recrystallisation temper

    then the metal is rolled into cold rolling mill machinery. These procedures are carried out to harden the

    metal according to the requirements of different companies.

    The Chassis driveis one of the drives used in controlling the speed of the gears of the steel rolling mi

    machines. This drive will be chosen for detailing in this paper.

    4.2 Chassis drive

    Squirrel-cage induction machines dominate ac industrial drive applications around the world for both ne

    and retrofit applications. Permanent magnet (PM) synchronous machines are increasingly popular choic

    high-performance servo applications because of their high power density. However, these represent on

    small fraction of the total number of industrial drive applications, the majority of which (i.e., pumps, fan

    can be satisfied with general-purpose induction motor drives using constant volts-per-hertz control.

    Other types of brushless machines including switched reluctance account for only a small fraction of ne

    industrial drive applications. Three-phase voltage source inverters using the basic six-switch bridge topo

    shown in Fig. 3(b) have become the overwhelming favorite for industrial drive applications less than 2 M

    During the past decade, IGBTs packaged in compact plastic power modules have rapidly expanded thei

    voltage and current ratings so that they now dominate nearly all of the new industrial drive inverter des

    Power modules are now available from several manufacturers with 1200-V IGBTs (appropriate for 460-V

    machines) that are packaged either as single-switches (2400 A), dual-switch phase legs (800 A), or com

    six-switch bridges ( 400 A), depending on the required current ratings. Continuing improvements in IGB

    switching characteristics allow these devices to be used with PWM switching frequencies that range from

    to 2 kHz in high-power drives ( 1 MW) to more than 20 kHz in lower power ratings ( 30 kW). IGBT pow

    modules are being offered with gate drives and protective functions built into the same package. Anothemark of progress is the growing availability of integrated power modules (IPMs) that provide all of the p

    semiconductors for a complete industrial drive in a single package, including IGBTs and diodes for the

    rectifier, inverter, and brake stages described in the following section.

    These integrated modules are already being produced with ratings of 1200 V and 50 A, with higher curr

    ratings now in development.

  • 8/6/2019 Industrial Drive

    14/23

    5.0 POWER CIRCUIT AND WAVEFORM

    Figure 4: Power Circuit of a Chassis drive

    5.1 WAVEFORMS

  • 8/6/2019 Industrial Drive

    15/23

    Figure 5: (a) Stator current waveform (b) Stator voltage and current

    The power waveform of the motor is as shown above using a computer based monitor.

    6.0 DESIGN OF THE POWER CIRCUITSThe architecture for a typical panel-mounted chassis drive in the 50-kW power range is illustrated in Fig

    The core of the power circuitry for this drive consists of an input three-phase diode rectifier, a precharg

    circuit, dc link capacitor bank, and IGBT inverter stage. Other power components shown in this figure

    including the input line ac reactor, input electromagnetic interference (EMI) filter, dc link reactor, dynam

    brake, and output filter are all optional depending on the application requirements.

    1) Inverter Stage:Modern IGBTs have matured to a high state of electrical ruggedness that makes it possible to design th

    inverter stages with a minimum of additional snubber circuitry to limit either the rate of current change

    di/dt) or the rate of voltage change (dv/dt ) at the IGBT terminals. In fact, many new IGBT inverters ar

    designed without any snubbers at all. This approach has the advantage of saving cost, space, and losse

    the inverterall positive effects. However, the resulting switching rates at the IGBT output terminals in

    snubberless inverter designs can sometimes exceed 1000 A s and 10 000 V s, which is undesired and, i

    some cases, harmful consequences. For example, it has been confirmed that the high switching rates ca

    interact with the inverter output cables and the machine windings to cause large transient voltages to a

    across the outermost turns of the stator windings. Field experience has demonstrated that this situation

    sometimes leads to catastrophic failure of the stator winding insulation. Such conditions are most likely

    occur in installations with unusually long cables between the drive inverter and machine. Some machine

    manufacturers have responded by strengthening the stator winding insulation, at least for the outermos

    turns.

    It was also found that the high switching rates can induce unbalanced charge build-ups on the machine

    by means of parasitic capacitances coupling the machine stator, the rotor, inverter switches, and ground

  • 8/6/2019 Industrial Drive

    16/23

    This accumulated rotor charge eventually discharges through the bearings if no other galvanic current p

    is provided. Over time, these discharges

    can cause serious pitting of the bearing balls and races that eventually leads to bearing failures under s

    circumstances that have been experienced in field installations. The introduction of insulated bearings o

    grounded rotor shaft brushes is among the solutions adopted by machine manufacturers to prevent the

    bearing failures.

    A third problem caused by the high and switching rates is elevated levels of conducted EMI in

    the drive input lines and ground that can easily exceed acceptable levels. Common-mode EMI can be

    significantly reduced by adding common-mode inductors in both the input and output lines, together wi

    small capacitors between each dc link bus and earth ground to prevent these high-frequency currents fr

    reaching the utility grid or machine. Modifications of the PWM switching algorithm can also be introduce

    minimize the generation of common-mode EMI. Differential-mode EMI can be reduced by adding passiv

    active filters on the inverter output lines. Another effective, albeit somewhat ironic solution to these EM

    problems is to use the IGBT gate drives to artificially slow their switching speeds, trading reduced EMI f

    elevated switching losses.

    2) Input Rectifier Stage:By showing a diode rectifier stage in Fig. 4, the illustrated architecture is typical of the

    large majority of todays industrial drives ( 90%) that do not permit braking power to be returned to the

    utility lines. Although the diode rectifier has the advantage of low cost, it also imposes several constrain

    and disadvantages on the drive system that are attracting more attention every year.

    Perhaps most importantly, the basic diode rectifier draws current from each input line that is significant

    distorted from its desired sinusoidal shape [Fig. 6(a)].One of the purposes of including either a dc link reactor or three-phase input line reactors in the drive p

    circuitry is to reduce the amplitude of the input current harmonics in addition to limiting the peak dc lin

    capacitor current and reducing the conducted EMI. However, Fig. 6(b) shows that, even when the ac lin

    reactors are introduced with typical ratings (3% of the drive base impedance, in this case), the input lin

    current harmonics are still very substantial, containing a fifth harmonic component greater than 40% of

    fundamental component. Another constraint imposed by diode rectifiers is the need for pre-charging of

    dc link capacitors to avoid dangerous surge current when the drive is initially connected to the ac line. A

    variety of pre-charge circuits are used depending on the drive power rating, including the parallel

    combination of resistor and bypass contactor illustrated in Fig. 4.

    For industrial drives with ratings greater than 30 kW, the diodes in the input rectifier stage are often pa

    or completely replaced by phase-controlled thyristors. Although more expensive than the diodes, the

    thyristors serve multiple purposes by providing the pre-charge function and serving as a fast electronic

    circuit breaker to remove power from the dc link in case of ground-fault or inverter failures.

    Many industrial drive applications that demand only limited and infrequent machine braking capability (e

    conveyors) can be satisfied by means of a dynamic brake assembly that dissipates the excess electrical

  • 8/6/2019 Industrial Drive

    17/23

    energy appearing on the dc link in external resistors (see Fig. 4). However, applications that involve freq

    and extended periods of

    braking (e.g., cranes) can justify the introduction of a regenerative input converter bridge as shown in F

    to provide the drive with bidirectional power conversion capabilities.

    The topology of the input converter bridge is identical to that of the inverter using six controlled switche

    (i.e., IGBTs) and six diodes, as shown previously in Fig. 3. Three-phase input line reactors are essential

    the active input bridge configuration to provide the necessary input impedance characteristics to the br

    terminals.

    The addition of the regenerative active input bridge clearly represents an expensive solution that can on

    justified today in applications that truly need bidirectional power flow.

    However, appropriate PWM control of the active input bridge results in significant system advantages by

    eliminating all of the undesirable low-order current harmonics that are associated

    with either diode or thyristor bridges, as well as providing independent control of the input power factor

    7 shows typical input line and dc link voltage/current waveforms for a regenerative drive system, illustra

    the major improvement in line current harmonics compared to the diode rectifier waveform shown earli

    Fig. 6. This figure also illustrates the fast response that regenerative input stages can provide using vec

    control principles handling a step change in drive operation from full-load motoring to full-load braking w

    minimal perturbations of the dc link voltage.

    3) Bus Capacitors:Electrolytic capacitors are the preferred choice for the dc link capacitors in almost

    industrial drives. Minimum dc link capacitance requirements are usually determined by the rms current-

    carrying capacity of the electrolytic capacitors and the need for sufficient dc link energy storage to allowdrive to ride through transient utility voltage sags. Typical electrolytic capacitor bank values for gener

    purpose drives fall between 25 and 50 F per amp of inverter rms output current. Since the voltage ratin

    electrolytic capacitors are usually limited to 500 Vdc or less, series and parallel combinations are require

    many drive applications to support dc link voltages that exceed these ratings.

    Newer film capacitors are available with higher rms current ratings per F of capacitance and better relia

    characteristics than their electrolytic counterparts. However, film capacitors are seldom used in place of

    electrolytics today because they are more expensive and smaller bus capacitance provides less drive rid

    through protection during utility voltage sag events.

  • 8/6/2019 Industrial Drive

    18/23

    7.0 CONTROL CIRCUIT WITH WAVEFORMS

    Fig. 6. Three-phase diode rectifier characteristics. (a) Input voltage and current

    waveforms. (b) Input current frequency spectrum.

    Figure 7: Block diagram of IGBT controlled drive of a 6Hi Cold Rolling Mill motors

    8.0 DESIGN OF THE CONTROL CIRCUIT

    The input voltage directly sets the oscillator and hence the inverter frequency. The input setting also

    determines the link voltage, so maintaining the voltage/frequency relationship. In order to march the m

    speed with the increasing frequency, the frequency must start from zero and rise at a rate such that the

    torque can accelerate the rotor to this rate.

    The ramp unit delays the rise of voltage resulting from any step input, and allows the inverter

    frequency to rise slowly, so maintaining stability during the accelerating period.

    The accuracy of the drive depends on the oscillator frequency.The DC link voltage adjustment

    controls the motor voltage magnitude and frequency within the inverter can be controlled.

  • 8/6/2019 Industrial Drive

    19/23

    The use of insulated gate bipolar transistors enables switching within the inverter to be faster an

    more efficient than thyristor circuit.

    Figure 8 : Diode-IGBT current switching characteristics for one inverter-leg, according to Martin (1996).

    refers to the upper and T to the lower transistor and+ is the freewheeling diode of the upper transisto

    9.0 APPLICATION IN THE LOCAL INDUSTRY WITH DIAGRAM

    The Chassis drive is used for controlling the speed, torque, voltage and current of the 6Hi Cold Rolling M

    motors.

    The aim is to reduce the thickness of hot rolled coil.

    Also, the drive is used for controlling the uncoiler motor, the edge trimmer, motor, and the recoiler mot

    shown below:

    Figure 9: Block Diagram of Cold Rolling Mill Machine

  • 8/6/2019 Industrial Drive

    20/23

    Figure 10: 6Hi Cold Rolling Mill Machine

    Figure 10(a) and (b) : Production Line pictures.

  • 8/6/2019 Industrial Drive

    21/23

    10.0 SELECTION OF DEVICES OF THE DESIGN SYSTEMS

    The devices used are:

    (a) Insulated Gate Bipolar Transistor based inverter

    (b) Converter transformer

    (c) Thyristor supply unit for conversion

    (d) Motor

    (e) Air Circuit Breakers (ACB)

    (f) Moulded Case Circuit Breakers (MCCB)

    (g) Contactor

    (h) Relays

    (i) Indicator Lamp

    (j) Fuse

    (k) Encoder

    11.0 PROBLEMS ASSOCIATED WITH THE USE OF THE DRIVE IN THE INDUSTRY

    1. The drive discussed above is a variable frequency drive, hence the introduction of harmonic

    Pollution by non-linear elements in the make up of the drive is a challenge the industries

    Face with the application of the drive.

    2. The resulting switching rates at the IGBT output terminals in snubberless inverter designs

    Employed in the drive can sometimes exceed 1000 A s and 10 000 V s, which is undesired and, in

    some cases, harmful.3. This high switching rates can induce unbalanced charge build-ups on the machine rotor by means o

    parasitic capacitances coupling the machine stator, the rotor, inverter switches, and ground. This

    accumulated rotor charge eventually discharges through the bearings if no other galvanic current pa

    provided. Over time, these discharges can cause serious pitting of the bearing balls and races that

    eventually leads to bearing failures under so circumstances that have been experienced in field insta

    tions

    4. Erratic power supply from the supply authority can cause huge damage during manufacturing

    12.0 RECOMMENDATION

    The stator winding insulation should be strengthened, at least the outer most insulation. Necessary filter circuit should be introduced to reduced the effect of harmonics. Insulated bearings or grounded rotors should be Incorporated to reduce the effect of

    bearing failure in the applications of the drive.

    Technology transfer method should be adopted to develop our local industry. Research and development of drives that suit the local industry should be vigorously pursue

  • 8/6/2019 Industrial Drive

    22/23

    13.0 CONCLUSIONS

    Drives are important in every manufacturing industry as they provide means of adjusting torque, spe

    voltage, current as regards to a given motor leading to reduction in the electrical energy demand of a

    system and industry at large.

    Local manufacture of drives will go a long way to developing our local technology as well as human

    resources.

    REFERENCES

    [1] Ashfaq Amhed, Power Electronics for Technology, Prentice Hall, New Jersey, 1999.

    [2] J.A. Odunsi, Electrical Installation, Design and Drafting, Yabatech Press, Lagos, 2000.

    [3] Cyril W. Lander, Power Electronics, McGRAW-HILL Book Company, England, 1993.

    [4] Katsuhiko Ogata, Modern Control Engineering, Prentice Hall, India, 2009.

    [5] O.D. Osunde, Bridgeless Asymmetrical Single Phase AC-DC Boost Converter for Power

    Factor Correction, Proceedings of the 3rd International Conference on Power Systems and

    Telecommunications, UNILAG, July 22nd-24th, 2009, pp52-55.

    [6] J.M.D. Murphy and F.G. Turnbull, Power Electronic Control of AC Motors, Pergamon Press,

    New York, 1988.

    [7] www.ABB.com(downloaded 25th April, 2010).

    [8] T. M. Jahns and E. L. Owen, AC adjustable-speed drives at the new millennium:

    Howdid we get here?, in Proc. 2000 IEEE Appl. Power Elec. Conf., New Orleans, LA,

    Feb. 2000, pp. 1826.

    [9] D. P. J. Link, Minimizing electric gearing currents in SSD systems,IEEE Ind. Appl. Mag.,pp. 5566, July/Aug. 1999.

    [10] S. Bhattacharya, L. Resta, D. M. Divan, and D.W. Novotny, Experimental comparison

    of motor bearing currents with PWM hard- and soft-switched voltage-source

    inverters,IEEE Trans. Power Electron., vol. 14, pp. 552562, May 1999.

    [11] M. Cacciato, A. Consoli, G. Scarcella, and A. Testa, Reduction ofcommon-mode currents

    in PWMinverter motor drives,IEEE Trans.Ind. Applicat., vol. 35, pp. 469477,

    Mar./Apr. 1999.

    [12] G. Oriti, A. Julian, and T. Lipo, Elimination of common mode voltage in three

    phase sinusoidal power converters, in Proc. IEEEPower Elec. Spec. Conf., Baveno,

    Italy, June 1996, pp. 19681972.

  • 8/6/2019 Industrial Drive

    23/23

    INDUSTRIAL DRIVE: AINDUSTRIAL DRIVE: AINDUSTRIAL DRIVE: AINDUSTRIAL DRIVE: A CASE STUDY OF CHASSIS DRIVECASE STUDY OF CHASSIS DRIVECASE STUDY OF CHASSIS DRIVECASE STUDY OF CHASSIS DRIVE

    EMPLOYEDEMPLOYEDEMPLOYEDEMPLOYED IN 6Hi SINGLE STAND REVERSINGIN 6Hi SINGLE STAND REVERSINGIN 6Hi SINGLE STAND REVERSINGIN 6Hi SINGLE STAND REVERSING

    COLD ROLLINGCOLD ROLLINGCOLD ROLLINGCOLD ROLLING MILLMILLMILLMILL

    BY

    AKINYELE, DAMILOLA JOHNSON

    [email protected]