WARNING FAILURE TO COMPLY WITH THE FOLLOWING WARNINGS COULD RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE SHOCK HAZARD • Disconnect electrical power supplies before installation or servicing. FIRE HAZARD • Do not exceed specified voltages. Only power transformers should be connected to line voltage. All other wires shall only connect to low voltage (24 VAC). Safely route and secure all wiring after installation. • Protect powered devices from direct contact with water. Replace any device exposed to water. (Does not apply to Supply Air Sensors, Return Air Sensors, Suction Line Sensors, Liquid Line Sensors.) • Installer must be a qualified technician, familiar with installation and service of HVAC equipment, associated wiring, and electrical codes. • Follow all local and national codes and ordinances. • The Sensi Predict power transformers are designed for connection to 120VAC or 240VAC volt electric powers within existing HVAC chassis only. • After installation or replacement, follow the HVAC manufacturer’s recommended instructions to ensure proper operation of the HVAC equipment. • Labeling any HVAC wires that need to be disconnected during the installation is recommended. The Sensi™ Predict kit is designed for conventional, residential HVAC equipment (furnace, AC, & heat pumps) in homes that have Internet access. The Sensi Predict system acts as a monitor only and does not provide any HVAC control. As the installing technician, it is your responsibility to know what requirements, hazards and precautions exist, and to install the monitoring system in a safe manner. Do not alter the mounting of parts within the HVAC equipment. INDOOR KIT INSTALLATION & ACTIVATION GUIDE 0037-7660002 The Sensi Predict Contractor PRO Portal can be accessed at sensipredictpro.com For login support, contact your office administrator. For support within the PRO Portal, call 1-877-424-1715. OPERATING CONDITION: Operating Temp -40°F to 158°F Storage Temp -40°F to 176°F ELECTRICAL RATING: Line Voltage Inputs 90-132VAC / 180- 264VAC Frequency 60Hz Control Line Voltage 24VAC at 60Hz CONTRACTOR SUPPORT: 1-877-424-1715

INDOOR KIT INSTALLATION & ACTIVATION GUIDE · 2019. 9. 30. · INDOOR KIT INSTALLATION & ACTIVATION GUIDE 0037-7660002 The Sensi Predict Contractor PRO Portal can be accessed at sensipredictpro.com

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: INDOOR KIT INSTALLATION & ACTIVATION GUIDE · 2019. 9. 30. · INDOOR KIT INSTALLATION & ACTIVATION GUIDE 0037-7660002 The Sensi Predict Contractor PRO Portal can be accessed at sensipredictpro.com

WARNING

FAILURE TO COMPLY WITH THE FOLLOWING WARNINGS COULD RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE

SHOCK HAZARD

• Disconnect electrical power supplies before installation or servicing.

FIRE HAZARD

• Do not exceed specified voltages. Only power transformers should be connected to line voltage. All other wires shall only connect to low voltage (24 VAC). Safely route and secure all wiring after installation.

• Protect powered devices from direct contact with water. Replace any device exposed to water. (Does not apply to Supply Air Sensors, Return Air Sensors, Suction Line Sensors, Liquid Line Sensors.)

•  Installer must be a qualified technician, familiar with installation and service of HVAC equipment, associated wiring, and electrical codes.

•  Follow all local and national codes and ordinances.

•  The Sensi Predict power transformers are designed for connection to 120VAC or 240VAC volt electric powers within existing HVAC chassis only.

•  After installation or replacement, follow the HVAC manufacturer’s recommended instructions to ensure proper operation of the HVAC equipment.

•  Labeling any HVAC wires that need to be disconnected during the installation is recommended.

The Sensi™ Predict kit is designed for conventional, residential HVAC equipment (furnace, AC, & heat pumps) in homes that have Internet access. The Sensi Predict system acts as a monitor only and does not provide any HVAC control.

As the installing technician, it is your responsibility to know what requirements, hazards and precautions exist, and to install the monitoring system in a safe manner.

Do not alter the mounting of parts within the HVAC equipment.

INDOOR KIT INSTALLATION & ACTIVATION GUIDE

0037-7660002

The Sensi Predict Contractor PRO Portal can be accessed at sensipredictpro.com For login support, contact your office administrator. For support within the PRO Portal, call 1-877-424-1715.

OPERATING CONDITION:Operating Temp -40°F to 158°F Storage Temp -40°F to 176°F

ELECTRICAL RATING:Line Voltage Inputs 90-132VAC / 180-264VAC Frequency 60Hz Control Line Voltage 24VAC at 60Hz

CONTRACTOR SUPPORT: 1-877-424-1715

Page 2: INDOOR KIT INSTALLATION & ACTIVATION GUIDE · 2019. 9. 30. · INDOOR KIT INSTALLATION & ACTIVATION GUIDE 0037-7660002 The Sensi Predict Contractor PRO Portal can be accessed at sensipredictpro.com

Sensi Predict Data Hub

Transformer Harness120VAC

Or

Transformer Harness240VAC

Power Transformer120VAC/240VAC – 24VAC

Main Cable(Keyed)

Supply Air SensorBlack Wire

Return Air SensorGray Wire

Suction Line SensorYellow Wire

Liquid Line SensorRed Wire

Current Sensor

SENSI™ PREDICT INSTALL KIT INCLUDES:

INDOOR KIT

CABLE & SENSORS

Cable Ties(15 pcs.)

Plastic Clips(8 pcs.)

Refrigerant Line Sensor Holder(2 pc.)

Grommet(1 pc.)

For Main Cable

Wire Nuts(2 pcs.)

8x1" Screws(2 pcs.)

8x¾" Screws(2 pcs.)

8x½" Screws(8 pcs.)

PARTS

Powerline Extender KitGatewayCondensate MonitorOutdoor Sensor Kit

Com

fort

Mon

itori

ng

OPTIONAL ACCESSORIESOUTDOOR KIT

Page 3: INDOOR KIT INSTALLATION & ACTIVATION GUIDE · 2019. 9. 30. · INDOOR KIT INSTALLATION & ACTIVATION GUIDE 0037-7660002 The Sensi Predict Contractor PRO Portal can be accessed at sensipredictpro.com

RSDA - 101

E000-0000-00A6-EB87

1. SETUP GATEWAY* CONFIRM WI-FI AND NOTE EQUIPMENT DATA

1. POWER THE SENSI PREDICT CONFIGURED GATEWAY•  Connect the Gateway power adapter to an outlet near the existing home router.•  Ensure the Gateway powers up.

2. CONNECT THE GATEWAY TO THE EXISTING HOME ROUTER•  Connect one end of the provided network cable to an open port on the Gateway. •  Connect the other end of the network cable to any open, numbered LAN port on

the existing home router.NOTE: If homeowner has a cable or DSL modem with only one Network (LAN) port and no router, then a router must be purchased and installed by the homeowner before install.

3. CHECK FOR WIRELESS SIGNAL AT THE FURNACE/AIR HANDLER•  Though the wireless network may be seen through your mobile phone or

tablet’s available Wi-Fi networks, it is important to check the desired wireless signal strength using a mobile app showing “Received Signal Strength Indication” or RSSI.

– For Android devices, use an app called Wifi Analyzer. – For iOS (Apple) devices, use an app called Airport Utility and enable

the Wi-Fi scanner function through the settings app. •  Confirm the Gateway’s RSSI level stays in a range of -70 to 0 dBm at proposed

Data Hub mounting location. •  If the wireless signal level at desired Data Hub mounting location is too low,

you may need to consider alternate Data Hub mounting locations or Powerline Extenders and Gateway to relocate a wireless network closer to Data Hub. For more information on using these free apps or Powerline Extenders, visit the Support section of the Sensi Predict Pro Portal, or call 1-877-424-1715.

4. WRITE DOWN THE ID FROM THE DATA HUB; YOU WILL NEED THIS DURING ACTIVATION

The Data Hub ID (located on the back side, just above the barcode) has 16 alpha-numeric characters. You may also take a photo to reference later in the install.

INDOOR EQUIPMENT DETAILS

System Type

Brand Year of Install

Model Number

Serial Number

Output KBTU KW

Filter Type

Filter Size H= W= T=

OUTDOOR EQUIPMENT DETAILS

System Type

Brand Year of Install

Model Number

Serial Number

Refrigerant Type

SEER Rating

Tonnage

*Gateway is an optional accessory–if not used jump to step 3

Page 4: INDOOR KIT INSTALLATION & ACTIVATION GUIDE · 2019. 9. 30. · INDOOR KIT INSTALLATION & ACTIVATION GUIDE 0037-7660002 The Sensi Predict Contractor PRO Portal can be accessed at sensipredictpro.com

3. INSTALL OPTIONAL OUTDOOR SENSOR KIT 4. PAIRING1. WPS PAIRING (all steps must be completed within 2 minutes)

•  Press the WPS button located on the gateway or have the homeowner start the WPS push-button pairing process for their wireless network (if supported otherwise go to step 2.)

•  Press and hold for 5 seconds the pairing button on the Sensi Predict Data Hub – The Data Hub is ready when the green and red LEDs remain solid, while the

amber LED blinks – If the Data Hub LEDs don’t indicate you are in the correct mode, re-try

depressing for 5 seconds the pairing button on the Data Hub

2. DIRECT PAIRING•  If WPS Pairing fails or is not available, use the Sensi Predict Pairing app to

directly pair to desired wireless network. •  Instructions are contained within the app.

NOTE: Once Data Hub is placed into direct pairing mode, it will stay in that mode for up to 5 minutes or until it receives wireless network credentials through the pairing app.

3. CONFIRM CONNECTION ON DATA HUB• Pairing may take a couple minutes to complete.•  Once a connection has been established, only the amber and green LEDs will be lit.•  The amber LED may flicker slightly to indicate data is being sent to the Sensi

Predict servers. NOTE: If there is any other light configuration you may need to repeat the process, or an Internet service problem may exist. If after three attempts you are unable to correctly pair the Data Hub, call 1-877-424-1715 for assistance.

BLINKING

PAIRING BUTTON

PAIRING

For more in-depth troubleshooting, visit the Support section of the Sensi Predict Pro Portal or call 1-877-424-1715.

BLINKING BLINKING BLINKING BLINKING

SUCCESSFULLY CONNECTED DATA HUB

Green and amber lights on.

•  Amber light may flicker.

POWERED ON / UNPAIRED

This display appears when:

•  Data Hub is first powered on.

•  After the Data Hub has been reset.

•  There is no Wi-Fi connection.

• Wi-Fi signal too weak.

DIRECT PAIRING / NOT CONNECTED

This display appears when:

•  Data Hub is in “Soft AP” mode for direct pairing to homeowner’s Wi-Fi.

•  Mobile device being used to pair needs to stay within range until pairing process completed.

WI-FI CONNECTED / NO SERVER

This display appears when:

•  Wi-Fi is connected, but data is not being communicated with the Sensi Predict servers.

•  Call for assistance to determine best next step. 1-877-424-1715

5. TROUBLESHOOTING

6. ACTIVATION• Complete the system activation process through the Contractor Portal – sensipredictpro.com

7. RUN A PERFORMANCE CHECK REPORT• Verify proper equipment operation and sensor installation, system must run for 10 minutes.•  View recent data or run an additional Performance Check through the Contractor Portal

by pulling up the homeowner’s account and manually running reports• Leave behind installation sheets/guides.

PAIRED

PAIRING BUTTON BLINKING

(instructions included with kit)