Upload
crystel-jaber
View
4
Download
0
Tags:
Embed Size (px)
DESCRIPTION
Indoor Air Quality
Citation preview
SUSTAINABLESUSTAINABLE
DESIGNDESIGN
1- Sustainable Site Planning
2- Safeguarding Water and Water Efficiency
3- Energy Efficiency and Renewable Energy
4- Conservation of Materials and Resources
5- Indoor Environmental Quality
Innovation and Design Innovation and Design ProcessProcess
5. Indoor Environmental Quality5. Indoor Environmental Quality
Indoor Air Quality Indoor Air Quality (IAQ)(IAQ) Light QualityLight Quality Acoustic QualityAcoustic Quality
Building Materials & Volatile Organic Compounds (VOCs)
Ventilation Effectiveness
Temperature and Relative Humidity
Controllability of Systems - as much control as possible is given to Controllability of Systems - as much control as possible is given to individual users, without compromising the effectiveness and efficient individual users, without compromising the effectiveness and efficient control of the overall systemcontrol of the overall system
Building Services Noise and Vibration
Control
Noise Control at the Source
Sound Isolation and Room Acoustics
A highly efficient light level distribution that improves visual quality while reducing electrical use may be achieved through efficient lighting layout, lamps, and luminaires.
Controllability of Systems
18/04/23 4
Controllability of Systems - as much control as possible is Controllability of Systems - as much control as possible is given to individual users, without compromising the given to individual users, without compromising the effectiveness and efficient control of the overall systemeffectiveness and efficient control of the overall system
Low-emitting Materials
18/04/23 5
Sources of Offgassing in Building Materials: 1- Paints 2- Ceiling tiles 3- Carpeting 4- VCT floor tiles 5- Manufactured wood products
Environmentally Friendly Architecture Reduces the use of materials that may Environmentally Friendly Architecture Reduces the use of materials that may release indoor air contaminants that are odorous or potentially irritating and release indoor air contaminants that are odorous or potentially irritating and might be harmful to occupant health, comfort and well-being. These materials might be harmful to occupant health, comfort and well-being. These materials must meet or be lower than the permissible VOC content limits (0.5 mg/m3)must meet or be lower than the permissible VOC content limits (0.5 mg/m3)
Ventilation, whether mechanical or natural, Ventilation, whether mechanical or natural, may be used for:may be used for:
Air Quality ControlAir Quality Control
Direct Indoor CoolingDirect Indoor Cooling
Direct Personal CoolingDirect Personal Cooling
Indirect Night CoolingIndirect Night Cooling
to control building air quality, by diluting internally-generated air contaminants with cleaner outdoor air
to directly cool building interiors by replacing or diluting warm indoor air with cooler outdoor air
to directly cool building occupants by directing cool outdoor air over building occupants at sufficient velocity
to indirectly cool building interiors by pre-cooling thermally massive components of the building fabric
Three Fundamental Strategies to Natural Three Fundamental Strategies to Natural VentilationVentilation
Wind-driven cross Wind-driven cross ventilationventilation
Buoyancy-driven Buoyancy-driven stack ventilationstack ventilation
Single-sided Single-sided ventilationventilation
Mixed Natural Ventilation Mixed Natural Ventilation StrategiesStrategies
Stack Ventilation With Sub-Stack Ventilation With Sub-slab Distributionslab Distribution
Elaborations of the Basic StrategiesElaborations of the Basic Strategies
18/04/23 8
• 1- Wind-driven cross ventilation occurs via ventilation openings on opposite sides of an enclosed space.
• 2- Buoyancy-Driven Stack Ventilation relies on density differences to draw cool, outdoor air in at low ventilation openings and exhaust warm, indoor air at higher ventilation openings.
Three Fundamental Strategies to Natural Three Fundamental Strategies to Natural VentilationVentilation
• 3- Single-sided ventilation typically serves single rooms and thus provides a local ventilation solution.
• Compared to the other alternatives, single-sided ventilation offers the least attractive natural ventilation solution but, nevertheless, a solution that can serve individual offices.
18/04/23 9
Three Fundamental Strategies to Natural Three Fundamental Strategies to Natural VentilationVentilation
• Mixed local/global and stack/wind ventilation strategy.
• Stack ventilation with sub-slab distribution
18/04/23 10
Elaborations of the Basic StrategiesElaborations of the Basic Strategies
Mixed Natural Ventilation Strategies
18/04/23 11
Zion National Park
Visitor Centre
1. Passive Down-Draft Cooltowers
2. computer-controlled operable windows
3. roof-integrated PV panel
4. radiant floor heating
Passive Down-Draft CooltowersWater sprayed on pads at the top of the towers evaporates, cooling the air. The cool, dense air “falls” through thetower and exits through the large openings at thebottom of the towers.
Natural VentilationThe high clerestory windows help coolthe center by allowing hot air to escape while low windows near thedoors allow cool air in. Computer controlsoperation of the clerestory windows.
Stack Ventilation With Sub-slab Distribution
• External walls (shielded from direct sunlight) • Heavy building mass• The enormous thermal mass of the building is used to regulate
the air temperature • Windows are small and do not exceed 25 percent of the
exposed surface area
18/04/23 17
Office Block in Office Block in Harare, Zimbabwe Harare, Zimbabwe suitable for hot suitable for hot zones,zones,Architects Pearce Architects Pearce PartnershipPartnership
(Source: Slessor, 1996)(Source: Slessor, 1996)
Major Technical Barriers to Widespread Use of Natural Ventilation
• Air and noise pollution in urban areas and city centres. presently lack proven filtration capabilities
• Controlling ventilation when natural driving forces are small
• Recovering heat from natural ventilation systems (an issue of concern to countries with very cold winters)
• Combating summer overheating• Integrating and maintaining natural ventilation
systems
18/04/23 18
Acoustic Quality (Noise Control)
• Controlling noise at the source• Controlling noise along its path
Reflected sound may be reduced by placing sound absorbing materials on surfaces from which sound will be reflected.
• Controlling noise at the receiver Direct ear protection (ear plugs or ear muffs) is often used to protect workers’ hearing when source and path noise control are not practical or possible (Temporary) Enclose the listener in an acoustically effective enclosure or Room (Permanent)
18/04/23 19
Attributes of Good Acoustic Quality
18/04/23 20
Sound rated partition up to ceiling
Sealed wall penetrations and acoustic baffle duct sections
Sound absorbent dropped ceiling
Sound absorbent insulation
Junctions vibration dampened
Sound rated partitions placed on structural floor
Sound absorbent partitions and furnishings
Floor slab floating on insulation
Sound reflecting transparent partitions to contain noise where feasible
Sound rated glazing
Sound absorbent flooring
“The technology of noise control both inside and outside buildings is well developed today. The problem is that it is too seldom used.” Robert B. Newman, Architect
YORK UNIVERSITY Computer Science Building - Case Study
Sustainable architecture main features• A central atrium to capture heat stratification
opportunities, thermal "chimneys" on the roof and a large component of operable perimeter glazing that maximizes free cooling in spring and fall and night time "flushing" in the summer. The result is stunning - energy consumption is 50% less than comparable buildings.
18/04/23 21
YORK UNIVERSITY Computer Science Building - Case Study
• The building features a planted roof, putting green space on the infill site to a "higher" use. The planted roof also acts as a holding tank for stormwater
• HVAC Plant is 50 % of normal size, resulting in significantly less emissions during operation.
• Natural Daylighting - All spaces access natural light either exterior or to interior atriums.
18/04/23 22
YORK UNIVERSITY Computer Science Building - Case Study
• Natural Ventilation: 100% Natural Ventilation during swing seasons. Operable window throughout, atrium spaces, thermal "chimneys" on roof; wind sensors control opening and closing of windows in upper atrium spaces.
• The building is acoustically sealed; reducing noise in or out. Extensive acoustic research was developed in concert with natural ventilation strategies. Acoustic lining is utilized to control noise in high air movement areas.
18/04/23 23
YORK UNIVERSITY Computer Science Building - Case Study
• Spaces are simple and fully flexible to accommodate changing future technologies. A continuous perimeter raceway allows cabling flexibility.
• Significant undercover bicycle storage ; shower rooms on every floor including disabled use. Building is also readily accessible via public transit.
18/04/23 24
YORK UNIVERSITY Computer Science Building - Case Study
• Building Section: diagrams natural daylighting and mechanical systems in winter season.
• Partial Section showing Natural Vent mode during shoulder seasons (Spring/Autumn).
18/04/23 25
YORK UNIVERSITY Computer Science Building - Case Study
• The building has the capability of performing as a naturally ventilated "tropical" structure. The hot climate design incorporates a central atrium to capture heat stratification opportunities. Thermal "chimneys" on the roof and a large component of operable perimeter glazing maximize free cooling in spring and fall and night time "flushing" in the summer.
18/04/23 26