Page 1: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating

performance

Neville Jordison Solex Thermal Science Inc. Canada

6th to 10th of May 2013. AGADIR MOROCO

Page 2: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

A Brief History

o Indirect Heat Exchanger introduced to the fertilizer industry approximately 25 years ago

o Today more than 100 coolers installed in fertilizer plants round the world

o Equipment operating successfully in every type of fertilizer- Urea (prills & granules), AN, CAN, LDAN, NPK, MAP, DAP, AS

o Company History

• 1990 - creation of Bulkflow Heat Exchangers – a technology division within Cominco Engineering Services Ltd

• 1999 - BULKFLOW TECHNOLOGIES is incorporated with headquarters in Calgary, Canada

• 2008 - Rebranded as Solex Thermal Science Inc to enhance profile as a world leader in the science of heating and cooling bulk solids

Page 3: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

Advantages compared to Air Cooling (Rotary or Fluid Bed)

o Low energy consumption

o No air usage – eliminates chillers, fans ducts and scrubber

o Compact design

o Lower installed capital cost

Page 4: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

Principle of Operation

Combines the science of mass flow with indirect heat transfer

• Product flows slowly by gravity between water cooled plates

• Product flows in uniform velocity mass flow

• Water flows counter-current inside plates

• Heat Exchange by conduction

Page 5: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

The Secret to Long Term Operating Performance

What causes Caking ?HYGROSCOPIC

PRODUCT

WATER COOLEDPLATES

HUMIDITYIN VOID SPACE

CONDENSATION

CAKING ON PLATES ×

Page 6: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

The Secret to Long Term Operating Performance

Preventing the Caking MechanismADD PURGE

AIR TO LOWERDEWPOINT

CORRECTWATER TEMP

PROFILE

ELIMINATECONDENSATION

NO CAKING

PURGEAIR

Page 7: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

The Secret to Long Term Operating Performance

The CRH Curve

Page 8: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

The Secret to Long Term Operating Performance

Thermal Modelling – Process Input Conditions

Page 9: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

The Secret to Long Term Operating Performance

Thermal Modelling – Output Temperature Profile

Page 10: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

The Secret to Long Term Operating Performance

Ensuring Water Temperature is above the Dew Point

Water temperature must be to right of

dewpoint line to prevent condensation

mechanism

Page 11: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

The Secret to Long Term Operating Performance

Complete System

o Tempered Water Module to provide controlled cooling water temperatures

o Purge air system controlled flowrate and dewpoint

o Instrumentation and Control System

Page 12: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

Pilot Testing at OCP Jorf Lasfar

o DAP

o Product Inlet Temperature 65 – 75°C

o Maintain discharge temperature below 50°C

o Demonstrate long term run capability without caking

Page 13: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

Pilot Testing at OCP Jorf Lasfar

Test Set-up

oDouble Bank Exchanger

oControlled Cooling Water Temperatures

oPurge Air system

oDemonstrate long term run capability without caking

PURGE AIR

PRODUCT IN

PRODUCT OUT

Page 14: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

Pilot Testing at OCP Jorf Lasfar

Product WaterPurge

Air

Steady-State Averages for

each run:

T° in

T° out

Rate

TOP BANKT° in

BOTTOM BANKT° out

Run 1 (July 17) 66-74°C 44-58°C 180 kg/h 65-72°C 43-58°C yesRun 2 (July 18) 71.5-74°C 45-46°C 230-370 kg/h 61°C 44-45°C yesRun 3 (July 20) 63-72°C 39-44°C 200 kg/h 58.5-60°C 40-45°C yes

Results

Page 15: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

Pilot Testing at OCP Jorf Lasfar

Plate Banks checked after each run

oRemovable Plexiglas plate

oPlate surfaces stayed clean throughout testing

Page 16: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

Typical DAP Cooler

o Product Flowrate: 100 t/h

o Product Size: 1 – 4 mm

o Product Temperature in: 85C

o Required Product Temp. out: < 50C

o Cooling Water: Cooling Tower at 28C

o Purge Air: Required

A = 10740B = 1650C = 1580E = 150F = 1800G = 2470J = 1390

Page 17: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

Typical DAP Cooler

o Water Temperature Control Module

o Primary water supply can be cooling tower or sea water – use 254SMO or titanium plate heat exchanger

o Purge Air Supply

o Unit typically installed immediately following the screens

Page 18: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

Recent Fertilizer Projects

Company Location Product CapacityYara Fertilizers Porsgrun, Norway NPK 210 t/hGemlik Gubre Gemlik, Turkey Amm. Nitrate 80 t/hNational Fertilizers Jagdishpur, India Urea Prills 2 x 155 t/h Zuari Fertilizers and Chem. Zuarinagar, India NPK 75 t/hJPMC Jordan DAP 2 x 70 t/h

Page 19: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

Large urea prill cooler during installation in India

Page 20: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance
Page 21: Indirect Plate Heat Exchangers for Cooling Fertilizer offer long term operating performance

Long Term Operating Performance

“This campaign the CAN Plant started up on 5th of June and until now The Solex Cooler hasn’t needed cleaning yet and is operating perfectly”.

Quote from Alp Bulent GULESGemlik Gubre Sanayii A.S.Sept 26th 2010

Thank you for your attention