INDICOM 2010

  • Upload
    ashok

  • View
    256

  • Download
    2

Embed Size (px)

Citation preview

  • 8/11/2019 INDICOM 2010

    1/20

    INDICOM 2010 (V2.2)

    News & Enhancements

  • 8/11/2019 INDICOM 2010

    2/20

    2Gernot Hacker, October 2009

    INDICOM 2010

    News

    Naming concept

    Channel Browser

    GigaBit support for IndiModul 622 & IndiSmart 612

    Raw data streaming

    Special measurement modes

    Sensor Admin

    Data Compression

    INCA Interface

    Enhancements

    Copy Object Attributes

    Interval Rounded

    Extensions to CA Processor

  • 8/11/2019 INDICOM 2010

    3/20

    3Gernot Hacker, October 2009

    NAMING CONCEPT

    By decision of the ITS top management the SPMTdeveloped a new concept for the AVL software Suite.This includes a naming concept as well as definition of

    the life cycle of the Suite. This concept was agreed onMay 5th 2009 and is valid from this date.

    The naming concept takes several boundary conditionsinto account defined by the messages that shall betransported:

    Make it easy for customers to know which productsfit together

    Keep value of product brands

    Emphasize system approach

    The name for the IndiCom version that will be releasedin October 2009 will be

    AVL IndiCom 2010

  • 8/11/2019 INDICOM 2010

    4/20

    4Gernot Hacker, October 2009

    CHANNEL BROWSER

    Channel Filter Set

    Allows users to assign channel filter criteria to a set of filters and save themunder a definable name. The defined channel filter sets can be activatedquickly via the channel filter list

    Data Point Filter

    Via the Data Point Filter option in a datasets context menu you can filterout the data points from a long measurement that are relevant for anevaluation. This function is useful e.g. in cases where the measurementhas several curves which then need to be evaluated individually. You cannow define a filter for the data key that returns only those records from all

    channels in which the value of the curve channel is 1. Data point filters areare ideally suited for control channels which contain the relevant curvenumbers (or phase, mode, cycle, etc.). It is then possible to filter by thesedata points.

    Dataset Display

    Datasets which are shown in any form in the current diagram window are

    now marked in Channel Browser by the corresponding formatting.Modifying Graphics Attributes

    Via the context auto toolbar of Channel Browser you can modify thegraphics attributes in one step in all tests and across the entire layout.Changes made at the file/test level will affect all displayed datasets of theselected test, at the channel/dataset level these will affect all displayed

    datasets of the same name.

  • 8/11/2019 INDICOM 2010

    5/20

    5Gernot Hacker, October 2009

    GigaBit SUPPORT FOR INDIMODUL & INDISMART

    The GigaBit device family is now completed withIndiModul and IndiSmart. All new devices aredelivered with IndiCom 2010. For more detailedinformation of the devices click on the pictures onthe left.

    AVL IndiModul GigaBit TM

    AVL IndiSmart GigaBitTM

    Adobe AcrobatDocument

    Adobe AcrobatDocument

    Only fo GigaBit systems!!

  • 8/11/2019 INDICOM 2010

    6/20

    6Gernot Hacker, October 2009

    RAW DATA STREAMING

    Raw Data Streaming is now available both on

    a time and angle basis . This allows users toalso measure the time data in Streamingmode.

    Benefits:

    Parallel streaming of time- andcrankanglebased raw data

    enables to perform realtime calculationof results on the PC (SoftRTP)

    save time because on measurementcompletion all data have already beentransferred to the PC

    new measurement solutions to recordall the necessary information

    Only fo GigaBit systems!!

  • 8/11/2019 INDICOM 2010

    7/20

    7Gernot Hacker, October 2009

    COLD START MEASUREMENT

    In this mode, normal angle-based parameters areautomatically converted internally into time values andmeasured. This way all signals involved in the cold start

    process are available as time-based data which are thenalso converted into an angle-based IFile. During themeasurement, the time-based signals are plotted overangle base using a fast macro.

    Benefits:

    Measurement of effects happening already before firstengine rotation (e.g. battery voltage drop)

    Data file with time- and crank angle based informationof all measured channels

    No need of complicated time to crank angleconversion after the measurement

    Online display of raw data and calculation results forfast engine start evaluation

    Only fo GigaBit systems!!

  • 8/11/2019 INDICOM 2010

    8/20

    8Gernot Hacker, October 2009

    SIMULTANEOUS EVENT RECORDING

    In this mode, if the Normal measurement mode isselected, a measurement can be saved to aseparate file after an event has occurred. This has

    the advantage that the event measurement takesplace regardless of normal test bed operation.Simultaneous measurements (single-, snapshot-or PUMA measurements) are not affected by this.

    Benefits:

    Execution of two measurement at the sametime

    Generation of separate measurement file foreasy data access

    Capturing of events on cyclic basis evenduring averaged measurements takes place

    Measurement 1

    Event 1 Event 2 Event 3

    Only fo GigaBit systems!!

  • 8/11/2019 INDICOM 2010

    9/20

    9Gernot Hacker, October 2009

    SNAPSHOT MEASUREMENT

    In order to record events that occur suddenly, thiscan now also be triggered very simply by pressing thespace bar. This measurement is possible in all

    measuring variants with Streaming and Monitoringand is independent of other measurements. Aseparate file (BackgroundFile) is created with adefinable name and path.

    Benefits:

    Capture of events even without defining anevent in the parameters

    Measurement of unpredictable events

    No disturbance of ongoing measurements

    Easy data handling by saving a separate file

    Only fo GigaBit systems!!

  • 8/11/2019 INDICOM 2010

    10/20

    10Gernot Hacker, October 2009

    MEASUREMENTS TRIGGERED VIA HARDWARE

    For special applications in test bed operation ameasurement can be started via an externalsignal (e.g. via Digital In ). This enables users to

    save data in sync with such an external signal.As of PUMA Open 2010 it is possible to performreal-time measurements using the function Bit-controlled measurement series .

    Benefits:

    Triggering a measurement via externalsurface feeler (e.g. two wheelerapplication)

    Triggering of measurements via externalBits for synchronization of differentmeasurement systemsSupport for Puma 2010 real timemeasurement

    Only fo GigaBit systems!!

  • 8/11/2019 INDICOM 2010

    11/20

    11Gernot Hacker, October 2009

    SENSOR ADMIN

    The additional program Sensor Admin can be calledvia the Utilities option in the workflow bar.

    Sensor Admin serves for sensor administration in anAccess database. When setting the parameters forthe amplifiers in IndiCom you can take over the

    respective sensors calibration data automaticallyfrom this database.

    With Sensor Admin you can add new sensors,delete old ones, make required adjustments anddisplay the sensitivity of the individual calibrations

    over time as a trend.

  • 8/11/2019 INDICOM 2010

    12/20

    12Gernot Hacker, October 2009

    SENSOR ADMIN

  • 8/11/2019 INDICOM 2010

    13/20

    13Gernot Hacker, October 2009

    DATA COMPRESSION

    IFiles can now be compressed automatically(xxx.zip). For this purpose, the Compress file(zip) check box under General tab underExtras | Pre-Sets Data Storage has to beactivated.

  • 8/11/2019 INDICOM 2010

    14/20

    14Gernot Hacker, October 2009

    INCA INTERFACE

    IndiCom 2010 is fully integrated into thecalibration software INCA. The OpenHardware Interface (OHI) from ETAS is usedto communicate between IndiCom & INCA.

    Benefits:

    Measurement control from INCA

    Data exchange from IndiCom to INCA

    Synchronization of time based INCA data& crank angle based IndiCom data

    Usage of IndiCom for thermodynamiconline calulation of indicating parameters

    Advanced data post processing inConcerto (MDF & IFile)

    Fast data check in IndiView (substitute ofMDA)

  • 8/11/2019 INDICOM 2010

    15/20

    15Gernot Hacker, October 2009

    INCA INTERFACE DEVICE INTEGRATION

  • 8/11/2019 INDICOM 2010

    16/20

  • 8/11/2019 INDICOM 2010

    17/20

    17Gernot Hacker, October 2009

    INCA INTERFACE LOAD PARAMETERFILE

  • 8/11/2019 INDICOM 2010

    18/20

    18Gernot Hacker, October 2009

    INCA INTERFACE CHANNEL LIST

  • 8/11/2019 INDICOM 2010

    19/20

    19Gernot Hacker, October 2009

    INCA INTERFACE ONLINE DISPLAY

  • 8/11/2019 INDICOM 2010

    20/20

    20Gernot Hacker, October 2009

    ENHANCEMENTS

    Copy Object Attributes

    The toolbar button Format Brush can be used to apply objectattributes (color, line width, line type, marker, label, font) of a

    given object to other objects of the same type. If the userselects a target object by right-click, a context menu will openshowing a selection of the attributes to be copied. If the targetobject is selected by left-clicking it, all attributes will be copied.

    Scale Range Property "Interval Rounded

    The functionality Interval Rounded was reactivated for thescale range settings. By deactivating this setting it is nowpossible to define an exact scale range without causing the gridspacing to be rounded.

    Extensions to CA Processor / 4CA1 CA calculator

    The Double Gap Mode allows users to use double-gap disks.The Delay Compensation for Inductive Sensors function canbe used to compensate for the speed-dependent delay ofinductive sensors.