17
Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 1 INCA v7.1 INCA V7.1 SP5 – What's New FUNCTIONALITY added by V7.1 SP5

INCA V7.1 SP5 What's New FUNCTIONALITY added by …archive.phiean.com/ETAS/INCA7.1/INCA_V71SP05/INCA-V7.1-SP05-Wh… · −CCP/XCP/UDS/KWP (with speed-up for CCP/XCP for better flashing

Embed Size (px)

Citation preview

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

1

INCA v7.1

INCA V7.1 SP5 – What's New

FUNCTIONALITY added by V7.1 SP5

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

2

− Product information (Use cases, Sample applications, Customer value)

− Performance

− Functionality

− Standards

− Usability

− HW support

− Add-ons

− INCA Product Family

− Phase out information

−General Notes

INCA V7.1 SP5 – What's New

Overview

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

3

− The binary representation shows blanks between each nibble

− If the data contains multiple flags combined this allows easy detection of the single

flags

INCA V7.1 SP5 – What's New

INCA Editors

Improved representation in Binary Format

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

4

− Product information (Use cases, Sample applications, Customer value)

− Performance

− Functionality

− Standards

− Usability

− HW support

− Add-ons

− INCA Product Family

− Phase out information

−General Notes

INCA V7.1 SP5 – What's New

Overview

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

5

Compressed Data

−MDF V4.1

−Compressed Data allows to reduce the size of the recorded measurement files

−The compression works without data loss

−Note: The tool to display the compressed file must support compression too

Standard Indexing

−MDF V3.x / V4.x

− INCA supports now the MDF Standard Indexing

−The ETAS Indexing optimized for the ETAS MDA is supported in parallel

−Note: The Indexing may be added later after recording

INCA V7.1 SP5 – What's New

MDF

MDF

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

6

Busload calculation for CAN-FD

− Respected by the Raster Check in INCA

Busload calculation for Ethernet

− Respected by the Raster Check in INCA

INCA V7.1 SP5 – What's New

XCP – Support of the XCP V1.2 features

Support of the XCP V1.2 features

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

7

Overruling allows to describe general parameters for different ECU

transport layers once and if necessary to overrule it for the specific ones

− different timings

− optional commands

−DAQ configuration

−Block mode Support

−Max_DTO/CTO

− etc.

With the support of multiple instances in INCA V7.1 it becomes important to be able to

overrule the common part. Each time another transport layer instance is selected the

configuration of the common part could change.

INCA V7.1 SP5 – What's New

XCP – Overruling Common Parameters within Transport Layer

XCP - Overruling Common Parameters within Transport Layer

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

8

ProF supports now beside the S19 S5 record type also the S6 record type

The S5 record type (2 byte size info) limits the block size to 65535 bytes. With the S6

record type (3 byte size info) now bigger blocks are possible

INCA V7.1 SP5 – What's New

S19 – ProF supports the S6 record type

Flashing via ProF with S19 files using S6 record type

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

9

− Product information (Use cases, Sample applications, Customer value)

− Performance

− Functionality

− Standards

− Usability

− HW support

− Add-ons

− INCA Product Family

− Phase out information

−General Notes

INCA V7.1 SP5 – What's New

Overview

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

10

The language of the

Service pack installer can

be selected independent

of the tool language

INCA V7.1 SP5 – What's New

Service Pack Installer – Multi Language

Multi Language Support for the Service Pack Installer

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

11

− Product information (Use cases, Sample applications, Customer value)

− Performance

− Functionality

− Standards

− Usability

− HW support

− Add-ons

− INCA Product Family

− Phase out information

−General Notes

INCA V7.1 SP5 – What's New

Overview

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

12

INCA V7.1 SP5 – What's New

ES581.4 Support

Flexible compact device

− ES581.4 USB CAN compact device

− Successor of ES581.3

− Small, pocket sized product for FlexRay interfaces

− Rugged housing with integrated USB cable

− Uses one high power (500mA) USB 2.0 connection

− Power and communication over USB

− 2 High-Speed CAN channels, electrical isolated

− CCP/XCP/UDS/KWP

(with speed-up for CCP/XCP for better flashing performance)

− Supports SAE J2534-1

− Multi-Client Support

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

13

− Product information (Use cases, Sample applications, Customer value)

− Performance

− Functionality

− Standards

− Usability

− HW support

− Add-ons

− INCA Product Family

− Phase out information

−General Notes

INCA V7.1 SP5 – What's New

Overview

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

14

IncaClose command was extended* by an additional parameter to determine

− if IncaClose disconnects and shuts down INCA

or

- if IncaClose disconnects leaves INCA open

Note:

The INCA-MIP Add-on is delivered as part of SP5 but is NOT updated automatically

by the Service Pack Installer for technical reasons.

To Update INCA-MIP to V16.1 please execute the installer manually.

*changes introduced with INCA-MIP V16.1 for INCA V7.1 SP5

INCA V7.1 SP5 – What's New

INCA MIP Add-on

INCA-MIP command IncaClose

now allows disconnect without shut down of INCA

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

15

− Support of the Matlab/Simulink Version 2014a in 32bit and 64bit

− Support of the new Mathworks model format *.slx

− SLX is a format that stores all model elements in a compressed XML format using

Unicode® UTF-8. The benefits of this new file format are:

− SLX has typically smaller file sizes than similar MDL files

− It solves problems with MDL files containing Korean and Chinese characters

− SLX enables incremental loading and saving which optimizes performance and

memory usage

INCA V7.1 SP5 – What's New

INCA SIP Add-on

INCA Simulink Integration Package

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

16

− Product information (Use cases, Sample applications, Customer value)

− Performance

− Functionality

− Standards

− Usability

− HW support

− Add-ons

− INCA Product Family

−Phase out information

−General Notes

INCA V7.1 SP5 – What's New

Overview

Public | ETAS-PGA | June 2014 | © ETAS GmbH 2014. All rights reserved, also regarding any disposal, exploitation, reproduction,

editing, distribution, as well as in the event of applications for industrial property rights.

17

−Maintenance stop for INCA under Windows XP

− Microsoft announced the end of the Extended Support for Windows XP by

8th of April 2014

http://support.microsoft.com/lifecycle/?LN=en-gb&C2=1173

− Therefore ETAS will discontinue the development and the maintenance of

INCA under Windows XP as following:

After Q2/2014 new INCA versions and Service Packs will not be tested under

Windows XP any longer. The installation under Windows XP will still be

possible, but is not recommended.

After Q2/2015 the installation of new INCA versions and Service Packs will no

longer be supported.

− We recommend Windows XP users to migrate to a newer Windows version

INCA SP5 – What's New

Maintenance Stop for INCA under Windows XP