27
INAR 243 FLOORS

INAR 243 FLOORS. Structural element Proper ground for functions

Embed Size (px)

Citation preview

Page 1: INAR 243 FLOORS.  Structural element  Proper ground for functions

INAR 243

FLOORS

Page 2: INAR 243 FLOORS.  Structural element  Proper ground for functions

FLOORS

Structural element Proper ground for functions

Page 3: INAR 243 FLOORS.  Structural element  Proper ground for functions

Functions

Load Bearing Insulation

Water Heat and water vapour control Sound

Fire control

Page 4: INAR 243 FLOORS.  Structural element  Proper ground for functions

Floors according to their functions and positions

Internal and External Ground and the others Raised floors ...

Page 5: INAR 243 FLOORS.  Structural element  Proper ground for functions

According to their materials

Reinforceconcrete (R.C) Timber Steel Stone Combination

Page 6: INAR 243 FLOORS.  Structural element  Proper ground for functions

R.C Slabs

Page 7: INAR 243 FLOORS.  Structural element  Proper ground for functions

R.C Slabs

One way slab One way Ribbed Slab(Joist Slab) Two way Slab Two way Waffle Slab (Grid) Two Way Flat Slab

Page 8: INAR 243 FLOORS.  Structural element  Proper ground for functions

In Situ Cast Reinforced Concrete Slabs

Reinforced concrete floors have a better resistance to damage by fire and can safely support greater superimposed loads than timber floors of similar depth.

The types of reinforced concrete slabs that are used for buildings are monolithic in situ cast slabs, waffled grid slabs, self-centering “T” beams and infill blocks, hollow beams and.

Page 9: INAR 243 FLOORS.  Structural element  Proper ground for functions

The word centering is used to describe the temporary platform on which in situ cast concrete floors are constructed and supported until the concrete has sufficient strength to be self supporting.The term self-centering is used to define those precast concrete floor systems that require no temporary support.

Page 10: INAR 243 FLOORS.  Structural element  Proper ground for functions

Monolithic Reinforced Concrete Slabs

The word monolithic is used to describe one unbroken mass of any material. A monolithic reinforced concrete floor is one unbroken solid mass between 100 and 300 mm thick, of in situ cast concrete, reinforced with mild steel reinforcing bars.

To support the concrete while it is still wet and plastic, and for 7 days after it has been placed, temporary centering has to be used. This takes the form of rough timber boarding, plywood, block board or steel sheets, supported on timber or steel beams and post.

Page 11: INAR 243 FLOORS.  Structural element  Proper ground for functions

The steel reinforcement is laid out on top of the centering and raised 20 mm or more above the centering by means of small blocks of fine concrete which are tied to the reinforcing bars with wire or by plastic spacers.

The wet concrete is then placed and spread on the centering and it is compacted and levelled of.

Page 12: INAR 243 FLOORS.  Structural element  Proper ground for functions

Waffle Grid Slabs

If the column grid is increased from about 6.0 about 12.0 square or near square it becomes economical to use a floor with intermediate cross beams supporting thin floor slabs.

The intermediate cross beams are cast on a regular square grid that gives the underside of the floor the appearance of a waffle, hence the name.

Page 13: INAR 243 FLOORS.  Structural element  Proper ground for functions

The advantage of the intermediate beams of the waffle is that they support a thin floor slab and so reduce the dead weight of the floor as compared to a flush slab of a similar span.

The economic span of floor slabs between intermediate beams lies between 900 and 3.5.

The waffle grid form of the floor may be cast around plastic or metal formers laid on timber centering.

Page 14: INAR 243 FLOORS.  Structural element  Proper ground for functions
Page 15: INAR 243 FLOORS.  Structural element  Proper ground for functions

Reinforced Concrete and Clay Block Slabs

The particular advantage of this type of floor is its good resistance to damage by fire.

To keep the death weight of the floor as low as possible, compatible with strength, it is constructed on in situ reinforced concrete beams with hollow terra cotta infilling blocks cast in between the beams.

The words terra cotta mean “earth burnt”.

Page 16: INAR 243 FLOORS.  Structural element  Proper ground for functions

This type of floor has to be given temporary support with timber or steel centering.

The terra cotta blocks and the reinforcement are set out on the centering and the pieces of clay tile are placed underneath the reinforcing bars.

Concrete is then placed and compacted between the terra cotta blocks and spread 50 mm thick over the top of the block.

Page 17: INAR 243 FLOORS.  Structural element  Proper ground for functions

Precast “T” Beam and Infill Block Slabs

This type of reinforced concrete floor is much used for comparatively small spans and loads.

The great advantage of this floor system is that, the small units can be handled by two men without the need for lifting gear.

Solid reinforced concrete beams usually shaped like an inverted T in section are precast in manufacturer’s yard to the required length.

The depth of the beams is from 130 to 250 mm and 20 mm wide at the bottom. The beams are made in lengths of up to 6 meter.

Page 18: INAR 243 FLOORS.  Structural element  Proper ground for functions

The “T” beams are reinforced with mild steel reinforcing bars.

Hollow precast light weight concrete infill blocks are made to fit between and bear on the “T” beams.

These blocks are hollow and made for lightness in handling and to minimize the weight of the floor.

The blocks are placed in position and floor completed with a layer of constructional concrete toping, 50 mm thick spread and levelled ready for a screed.

The under side or soft feet of the floor is covered with plaster or will provide support for a suspended ceiling.

Page 19: INAR 243 FLOORS.  Structural element  Proper ground for functions
Page 20: INAR 243 FLOORS.  Structural element  Proper ground for functions
Page 21: INAR 243 FLOORS.  Structural element  Proper ground for functions
Page 22: INAR 243 FLOORS.  Structural element  Proper ground for functions
Page 23: INAR 243 FLOORS.  Structural element  Proper ground for functions

Hollow Beam Slab Units

Hollow, reinforced concrete beams are precast around inflatable formers to produce the hollow cross section.

The beams are rectangular in section with the steel reinforcement cast in the lower angles of the beam.

The sides of the beams are indented to provide a key for the concrete toping.

Page 24: INAR 243 FLOORS.  Structural element  Proper ground for functions
Page 25: INAR 243 FLOORS.  Structural element  Proper ground for functions
Page 26: INAR 243 FLOORS.  Structural element  Proper ground for functions
Page 27: INAR 243 FLOORS.  Structural element  Proper ground for functions