HCS2000A Digital Control System
Item Qty. Description
6 1 Control system parameter:
Charging voltage:
Setting range 0~100.0kV
Operating space 10.0~100.0kV
Setting deviation ≤±1%
Instability ≤±1%
Setting resolution 0.1kV
Charging time:
Setting rang 20~190s
Setting resolution 1s
Alarm time-delay 2s
Raise voltage times:
Setting rang 1~999
Protection setting:
Over-Current protection Settable
Over-Voltage protection Settable
Trends Charging Protection Selectable
Static Charging Protection Settable
Trigger pulse >15kV, raising time <100ns, polarity is switchable.
Output impulse stability >99%
WWW.HIMALAYAL.COM.CN
T: 86 21 6101 6212 Himalayal, always by your side. Copy right © HIMALAYAL
[email protected] All right reserved. Page: 2
Main function:
HCS2000A controller can realize manual control, automatic control and
programmed control, main function are like following:
Measuring display:
DC charging voltage
Transformer primary current
Generator sphere gap distance
State display:
Main power connector switching state
Ground device switching state
Generator sphere gaps trigger state
Generator charging voltage polarity state
Control:
Control system can realize manual control, automatic control and programmed
control, each function is independent.
Adopt controllable silicon regulating method, has charging voltage feedback
measuring system
Sparking sphere gap and chopped gap distance is adjustable manually or
automatically, and display on the interface.
Equips time-delay adjustable chopping gap trigger pulse, and generator spark
trigger feedback system
Adopt functions controlled constant current charging methods, charging voltage
stability can reach 0.5%.
Liquid crystal display panel can indicate generator’s charging voltage and
charging process, accuracy is 1%.
Can direct input charging voltage and time from liquid crystal display panel
Equips charging abnormal protection function, the trigger spark pulse can be
generate manually or automatically
Generator working status indication, such as: spontaneous combustion, not
trigger, charging abnormal, charging stable, and so on.
System generator and charging parts ground and ground decontrol
The charging voltage polarity can be changed by press the bottom in the
controller.
The charging process can be controlled manually or automatically
Alarm bell (manual or automatic)
Protection and interlock:
Over-current protection
Over-voltage protection
Abnormal discharge protection
Door open/close interlock
Ground facility interlock
Polarity reversal interlock
Operation indication:
WWW.HIMALAYAL.COM.CN
T: 86 21 6101 6212 Himalayal, always by your side. Copy right © HIMALAYAL
[email protected] All right reserved. Page: 3
Can supply different operation indication, when system error or disoperation, the
interface will come up relative indication.
Dimension: 750x900x1250mm
Measuring system:
Amplitude measurement: Impulse peak voltmeter (Selectable)
Input range: 100V ~ 1000V(Impulse voltage)
Uncertainty of measurement: <1%
Waveform measurement: TDS3012C digital oscilloscope
Waveform analysis: Grind China industrial control computer
Outer dimension: 750mm*900mm*1250mm
Weight: 110KG
IGMS-1200 Automatic impulse voltage signal analyzing and measuring
system
Item Qty. Description
7 1 1) Amplitude measurement: Impulse peak voltmeter (Selectable)
2) Input range: 100V ~ 400V(Impulse voltage)
3) Uncertainty of measurement: <1%
4) Waveform measurement: TDS3012 digital oscilloscope
5) Max. Sampling rate 1.25GS/s, Bandwidth>100MHz, resolution: 9bit
6) Record length: 10k byte (Meet the requirement of impulse voltage test)
7) Waveform analysis: Grind China industrial control computer
8) Impulse measuring software package:
A. Automatic setting oscilloscope parameter
B. Impulse waveform parameter calculation and display
C. Waveform comparing function
D. Waveform amplification, zoom out, translation
E. Waveform storage and invoking,
F. Waveform Diagram and report
Enclosure:
High performance 100 times dedicated attenuator 2 pcs
A4 Laser printer 1 set
Isolation filter shielding designation
Software operation interface:
WWW.HIMALAYAL.COM.CN
T: 86 21 6101 6212 Himalayal, always by your side. Copy right © HIMALAYAL
[email protected] All right reserved. Page: 4
Back side of the control console:
Front side of the control console:
WWW.HIMALAYAL.COM.CN
T: 86 21 6101 6212 Himalayal, always by your side. Copy right © HIMALAYAL
[email protected] All right reserved. Page: 5
Interface of the measuring system:
Setting interface of the measuring system. 2channels available, if need 4 channels, our system
expandable.
WWW.HIMALAYAL.COM.CN
T: 86 21 6101 6212 Himalayal, always by your side. Copy right © HIMALAYAL
[email protected] All right reserved. Page: 6
Test data will be show on the measuring interface and can be record in the industrial computer.
WWW.HIMALAYAL.COM.CN
T: 86 21 6101 6212 Himalayal, always by your side. Copy right © HIMALAYAL
[email protected] All right reserved. Page: 7
Triggering distance setting interface:
WWW.HIMALAYAL.COM.CN
T: 86 21 6101 6212 Himalayal, always by your side. Copy right © HIMALAYAL
[email protected] All right reserved. Page: 8
Impulse testing setting:
WWW.HIMALAYAL.COM.CN
T: 86 21 6101 6212 Himalayal, always by your side. Copy right © HIMALAYAL
[email protected] All right reserved. Page: 9
Charging parameter setting:
Measuring system:
WWW.HIMALAYAL.COM.CN
T: 86 21 6101 6212 Himalayal, always by your side. Copy right © HIMALAYAL
[email protected] All right reserved. Page: 10
Oscilloscope Tektronix 3012 is fixed inside of the control console.
WWW.HIMALAYAL.COM.CN
T: 86 21 6101 6212 Himalayal, always by your side. Copy right © HIMALAYAL
[email protected] All right reserved. Page: 11