Upload
swetha-reddy
View
213
Download
4
Embed Size (px)
Citation preview
© 2009 Hitachi Data Systems
Hitachi Storage Command Suite
Improve Storage Administration with Hitachi Device Manager version 6.1
February 18, 2009
John Harker
Senior Product Marketing Manager
Himanshu Parida
Technical Product Manager
Norma Rangel
Product Manager
2
Hitachi Data Systems WebTech Educational Seminar Series
Improve Storage Administration with Hitachi Device Manager version 6.1
Technical Session: Hitachi Device Manager software is now standard with the Hitachi Universal Storage Platform™. The new release of Device Manager features improvements in storage administration including Host Scan. With Host Scan, Device Manager now makes it easier to map SAN viewed worldwide names to host names through the ability to name the hosts attached to a given subsystem with names obtained from its HSD or iSCSI target. Join us for a quick overview of what’s new in Device Manager.
In this webcast detailing Device Manager 6.1, you’ll understand:– How to configure host groups using the new host scan feature
– All about the new host mode options and device support in Device Manager
– How to take advantage of the other new Device Manager features such as,
updated SMI-S support, installation improvements and more
3
Agenda
Improve Storage Administration with Hitachi Device Manager version 6.1
• Simplified Host Management
• SMI-S enhancements
• Device Manager External Device Discovery
• Tiered Storage Manager Volume Creation
• Device Manager SMI-S 1.3 support
• Other enhancements
• Hardware and Supported environment support update
4
Device Manager Host View
• Add Hosts
– With agent automatically maps in Hosts w/proper names
– Without Host agent you use Lunscan which gives you numbered host names
– New Host Scan feature gives you real host names
5
Simplified Host Management
• Device Manager version 6.1 introduces Host Scan feature to reduce time consuming host registration tasks in the agentless environment.
• Host scan discovers worldwide names which are not assigned to any host in Device Manager from subsystems, then generates a host based on the Host Storage Domain (HSD) or iSCSI target
– The HSD or iSCSI nickname will be used as the host name.
Host Scan
6
Simplified Host Management - GUI
• Host view provides “Execute Host Scan” button to generate hosts.
More than one subsystem can be selected.
7
Simplified Host Management – CLI
• “HostScan” command is supported to generate hosts automatically.
The serial number of the subsystem. Comma can be used to delimit values.
The subsystem model. Comma can be used to delimit values.
Description
serialnum
model
Parameter
1. Parameters required to scan particular subsystems,
The option to scan all subsystem. “all” should be specified.
Description
option
Parameter
2. Parameter required to scan all subsystems,
Note: since both model and serialnum values are used to identify a subsystem, the order of these values are important when more than 1 subsystem is scanned.
>HiCommandCLI HostScan model=USP_V,USP serialnum=10007,10505
Example: Run HostScan command to the USP V with serialnum 10007 and the USP with serialnum 10505.
8
Device Manager SMI-S Enhancements
• SMI-S Provider Configured by Default
• SMI-S Enabled Subsystem Support
– Discovery
– Reporting
– Storage management tool launch
– Refresh and removal
• SMI-S 1.3 Support
9
SMI-S EnhancementsProvider Configured by Default
• SMI-S provider service is automatically enabled and the setting panels are removed in order to simplify the installation process in V6.1 or later.
• Device Manager configures the service as following,– SMI-S provider service: Enable
– SLP service: Enable
– SMI-S SSL Port: 5989
– Two-way Authentication for object operations: Disable
– Two-way Authentication for event indication: Disable
– SMI-S agent host name: will not be specified
• The configuration can be changed by modifying properties in the server. properties file.
– The properties file location
• In Windows, <installation-folder-for-the-Device-Manager-server>\Server\config\server.properties
• In Unix, <installation-folder-for-the-Device-Manager-server>/Server/config/server.properties
– If the properties are changed, Device Manager server has to be restarted to take effect.
10
SMI-S Enabled Subsystem Support
• Device Manager server communicates with SMI-S providers to retrieve a subsystem information and to configure the subsystem.
Management Server
SMI-S Provider
EMC Navisphere Manager
Management Server
SMI-S Provider
HP Command View EVA
Management Server
Web Server
Hitachi Device Manager
Java App
HDvM Server
SMI-S ClientCLARiiON
EVA
HDvM Server to SMI-S Provider
SMI-S Provider to subsystemsLAN
5988http
5989https
Default Port NumberCommunication
Type
Network Configuration
Default network port SMI-S providers listen on
11
SMI-S Enabled Subsystem Support
• Hitachi Device Manager 6.1.1 now supports the following SMI-S enabled subsystems to simplify the virtualization process.
– EMC CLARiiON
• CX200, CX300, CX400, CX500, CX600, CX700, CX3 series
– HP StorageWorks Enterprise Virtual Array (EVA)
• 3000, 4000, 4400, 5000, 6000, 8000
• SMI-S providers have to be set up to manage subsystems so that Device Manager can discover the SMI-S enabled systems.
1.2HP StorageWorks Command View EVA 8.0.2 or laterHP
EMC
Vendor
1.2
SMI-S version
EMC Solutions Enabler 6.5 or later
EMC SMI-S Provider 3.3 or later
SMI-S Provider
12
SMI-S Enabled Subsystem Discovery - GUI
• “Add Subsystem” feature is enhanced to register SMI-S enabled subsystems to HDvM.
• IP address or host name of the SMI-S provider server has to be specified.
• Device Manager discovers subsystems that the SMI-S provider manages.– If 2 subsystems are managed by the SMI-S providers, Device Manager
discovers 2 subsystems.
Subsystems View
“SMI-S_Enabled” should be selected from the drop down list.
5989
5988
Default Port Number
Non-Secure
Secure
Protocol
- The protocol and the port number depends on the SMI-S provider setting.- “Secure” protocol is selected as a default.
A user with administrator privileges to the SMI-S enabled subsystems should be registered.
13
SMI-S Enabled Subsystem Reporting - GUI
• Basic subsystem information is reported on the Subsystems view.
– The vendor name and serial number are provided to identify the subsystem.
– The configured capacity is the total capacity of volumes.
Subsystems View
14
Storage Management Tool Launch - GUI
• Device Manager provides a capability to launch third vendor storage management tools from the subsystem view.
• The launch URL is retrieved from the SMI-S provider at the time of the discovery.
– The URL used to launch the management tool is from “AccessInfo” property in CIM_RemoteServiceAccessPoint class.
– The launch URL can be manually registered or overwritten by using Device Manager CLI.
HP StorageWorks Command View EVA launch EMC Navisphere Manager launch
15
SMI-S Enabled Subsystem - Others
• “Modify Properties” feature is provided to handle the SMI-S provider machine replacement, user or password change.
– Once “Modify Properties” is performed, the subsystem will be refreshed automatically in addition to change the properties.
• Refresh can be used to update the subsystem configuration information to Hitachi Device Manager.
• “Remove Subsystem” button is provided to remove the specified SMI-S enabled subsystem from Device Manager.
Modify PropertiesRefresh
User ID
Port Number
Protocol
Password
IP Address
Name
Properties
Properties the user can change
Remove
16
SMI-S Enabled Subsystem Support - CLI
• AddStorageArray command is enhanced to discover a SMI-S enabled subsystem.
Optional
Optional
Required
Required
Required
Required
Required
Condition
Password used to access to the SMI-S providerarraypasswd
Either of protocols can be specified,
Non-secure: HTTP communication
Secure: HTTPS communication
If omitted, “Secure” will be set.
protocol
Specify “SMI-S_Enabled”.displayfamily
User ID used to access to the SMI-S provideruserid
Specify “SMI-S_Enabled”family
portnumber
ipaddress
Parameter
The port number the SMI-S provider listens. The default value is set according to the specified protocol.
5988: Non-secure
5989: Secure
The IP address or host name of the SMI-S provider
Description
>HiCommandCLI AddStorageArray ipaddress=10.123.15.1 family=SMI-S_Enabled displayfamily=SMI-S_Enabled
userid=dvm arraypasswd=dvm
...
AddStorageArray command parameters
Sample:
17
SMI-S Enabled Subsystem Report - CLI
• 2 commands are supported to report basic subsystem and the SMI-S provider information.
– GetStorageArray
– GetStorageArray (subtarget=CommParameters)
>HiCommandCLI getStorageArray subtarget=commparameters
saobjid=CLARiiON+APM00051603452
RESPONSE:
An instance of StorageArray
objectID=CLARiiON+APM00051603452
name=CLARiiON(CLARiiON+APM00051603452)@172.17.173.68
serialNumber=CLARiiON+APM00051603452
arrayFamily=SMI-S_Enabled
arrayType=CLARiiON(Rack Mounted CX300)
numberOfControllers=-1
capacityInGB=2,463
...
capacityInKB=2,582,644,551
...
lastRefreshed=1,231,866,336
...
List of 1 CommParameters elements:
An instance of CommParameters
arrayFamily=SMI-S_Enabled
ipAddress=172.17.173.68
portNumber=5989
protocol=Secure
userID=root
Sample:
saobjid
Parameter
-The object ID of the SMI-S enabled subsystem.
- An object ID can be obtained by executing GetStorageArray command without specifying any parameters.
- If Object ID of Hitachi storage subsystem is specified to the parameter, the command returns an error.
Description
Reuired parameter to report particular subsystem
18
SMI-S Enabled Subsystem Refresh and Removal - CLI
• AddStorageArray command supports to refresh particular SMI-S enabled subsystem.
• DeleteStorageArray command can be performed to remove SMI-S enabled subsystem from HDvM.
saobjid
Parameter
The object ID of the subsystem.
An object ID can be obtained by executing GetStorageArray command without specifying any parameters.
Description
Reuired parameter to refresh and remove the subsystem
>HiCommandCLI AddStorageArray saobjid=CLARiiON+APM00051603452
RESPONSE:
An instance of StorageArray
objectID=CLARiiON+APM00051603452
name=CLARiiON(CLARiiON+APM00051603452)@172.17.173.68
serialNumber=CLARiiON+APM00051603452
...
Sample: DeleteStorageArray
>HiCommandCLI DeleteStorageArray saobjid=CLARiiON+APM00051603452
RESPONSE:
(Command completed; empty list returned)
Sample: AddStorageArray (Refresh)
19
Tiered Storage Manager version 6.1 SMI-S Storage Management Enhancements
• Hitachi Tiered Storage Manager supports external storage configuration to simplify constructing external storage tiers
– Supported local subsystem (Storage Domain)
• Hitachi Universal Storage Platform™ V or Universal Storage Platform VM, microcode version 60-04-xx-xx/xx or later
– Supported external subsystem (SMI-S enabled subsystem)• EMC CRALiiON CX, CX3
• HP Enterprise Virtual Array (EVA)
Note: Both local and external subsystems have to be first discovered by Hitachi Device Manager.
High Performance Tier
External Storage Tier
VolumeMigration
Universal Storage Platform V
CreateMap
External Subsystem(SMI-S Enabled)
20
Tiered Storage Manager 6.1 SMI-S Storage Management Enhancements
• Prerequisites
– Ports in a Universal Storage Platform V or Universal Storage Platform VM are configured as external ports.
– The external ports defined in a Universal Storage Platform and the target port
in external subsystem are physically connected by the Fibre Channel.
– The storage pool which is equivalent to Array Group in the external
subsystem has been already prepared.
• The following chart shows operation flow,
Create a volume in the external
subsystem (option)
Create a volume in the external
subsystem (option)
Search a volume in the external subsystem
Search a volume in the external subsystem
Create External Mapping Task
Create External Mapping Task Execute the Task
Execute the Task
21
Tiered Storage Manager 6.1 SMI-S Volume Creation – Free Space Search
• Free space search capability is supported in order to create volumes.
Search ScreenSMI-S enabled subsystems managed by Device Manager can be selected from Search in box.
Note:
-Emulation type columns will be blank since this is Hitachi specific.
-“Disk Type”, “Disk Capacity”, and “Disk RPM” are unknown since SMI-S provider returns it.
CLARiiON
EVA
- ”Capacity”, ”Total Free Capacity”, and “RAID Level”search attributes can be used to search specific free spaces.
- If no search attributes are selected, all free spaces in the subsystem will be displayed.
22
Tiered Storage Manager 6.1 SMI-S Volume Creation
• Once a free space is found in the result, the user can select the free space and click “Create Volume” button to start setting parameters for the volume to be created.
• Only the capacity can be entered for SMI-S enabled subsystems.
-Capacity can be specified in KB, MB, GB, and TB, but decimal point cannot be specified.
-The option can be checked to execute task after the confirm button is clicked.
- The default is checked and executing the task immediately.
Only one Free Space can be selected.
Search Screen
23
Tiered Storage Manager 6.1 SMI-S Volume Creation – Volume Creation Task
• A volume creation task is generated and can then be executed.
Task Screen
- SMI-S enabled subsystem information is displayed on the Detailed Information tab.
-The component status shows the volume to be created and volume ID will be assigned by SMI-S enabled subsystem.
24
HTSM SMI-S Volume Creation – Volume Creation Task
• The task status will be changed as soon as the volume creation task is executed.
Status Transition
• Volume ID is assigned automatically by SMI-S enabled subsystem.
• Volume ID format depends on the vendor.
EMC
OR
25
Device Manager 6.1SMI-S 1.3 Support
• Autonomous Profiles: Array, Server
• Component Profiles: Access Points, Block Server Performance, Block Services, Disk Drive Lite, Extent Composition, FC Initiator Ports, FC Target Ports, Location, Masking and Mapping, Multiple Computer System, Object Manager Adapter, Physical Package, Profile Registration, Software, iSCSI Target Ports
• Early Adopter Component Profiles: Block Storage Views, Storage Element Protection, Volume Composition
• Note on Object Manager Adaptor subprofile support
– CIMOM supports HTTP and HTTPS for the communication protocol.
– The subprofile provides classes so that a client can start or stop the communication in HTTP or HTTPS.
– The default is HTTP.
26
Other Installation Enhancements
Server Installation Enhancements
• Improved multiuser support
• Free Space attribute support
• Device Manager and Tiered Storage Manager Installation Integration
• Unattended Installation Enhancement
Agent installation Enhancements
• Required patches verification
• Unattended un-installation
• Hiscan Default Value changes
27
Hardware Support
• Universal Storage Platform V and Universal Storage Platform VM Enhancements support
– Encrypted device identification
– New host mode options support
– 450GB 15K rpm Fiber Channel disk drive identification (CLI)
• Additional Enhancements for Hitachi Universal Volume Manager
– Path priority configuration (CLI)
• Hitachi Adaptable Modular Storage 2000 family and Hitachi SimpleModular Storage Enhancements support
– SAS 450GB disk drive identification
– Restriction for SSL communication
28
Encrypted Device Identification
• As the Universal Storage Platform V and Universal Storage Platform VM support data encryption, Hitachi Device Manager reports LDEVs and array groups which encrypted data is contained.
• Encrypted LDEVs can be identified by looking at “Volume Attr” and listed by using filtering feature on GUI.
• “Encrypted” attribute is added to LDEV and Array Group instances and the 2 commands report the attribute.
– GetStorageArray(subtarget=ArrayGroup)– GetStorageArray(subtarget=LDEV)
>HiCommandCLI GetStorageArray
subtarget=LDEV model=USP_V serialnum=10007
RESPONSE:
An instance of StorageArray
(Attributes of StorageArray are omitted
here)
List of 6930 Ldev elements:
An instance of LDEV
objectID=*****
devNum=0
displayName=00:00:00
...
encrypted=1
...
For arrays other than USP V/VM-1
The data is encrypted1
0
Value
The data is not encrypted
Encrypted
DescriptionAttributeGUI
CLI output attribute
Sample: GetStorageArray (subtarget=LDEV)
29
New Host Mode Options Support
• The following host mode options are supported by the Universal Storage Platform V and Universal Storage Platform VM and the options can be set by Device Manager GUI and CLI.
Add Storage Wizard
Inquiry/ Report LUN is started by priority configured by the host or HBA.41Prioritized device recognition command
This is required for IBM Z10 Linux.42Prevent "OHUB PCI retry“
The capacity will be recognized by a host after increasing the THP volume capacity.
The host mode has to be Windows( mode 0C) or Windows Extension (mode 2C)40V-Vol expansion
Queue Full Response
Set/Report Device Identifier enable
Host Mode Option
When Queue Full occurs, Queue Full is always returned to the host.
This is used to set a nickname for a device.
One of the host mode, HP (mode 03), OpenVMS (mode 05), or Tru64 (mode 07) is
required.
Description
43
33
Values
• The host mode options can be specified to hostModeOption parameter in the following commands.
– AddHostStorageDomain
– ModifyPort
30
New Fiber Channel Disk Drive Identification
• Universal Storage Platform V and Universal Storage Platform VM support 450GB 15K rpm Fiber Channel disk drive.
• Device Manager CLI reports the disk drive.– GetStorageArray (subtarget=PDEV)
>HiCommandCLI GetStorageArray subtarget=PDEV model=USP_V serialnum=10007
RESPONSE:
An instance of StorageArray
(Attributes of StorageArray are omitted here)
List of 1 PDEV elements:
An instance of PDEV
objectID=****
chassis=1
arrayGroup=224
arrayGroupName=1-15-1
capacityInKB=430,240,385
row=-1
column=-1
depth=-1
role=
vendor=
model=DKR2H-K450FC
firmwareVersion=
serialNumber=
dkuType=USP_V/VM
rpm=15000
diskType=-1
pdevid=3,584
...
31
External Storage Setting Enhancement
• AddExternalArrayGroup command which is used for the volume mapping is
enhanced to set the path priority.
• “portname”,”externalwwn”, and “externallun” values are specified as a set to define
a mapping path and the set order will be the priority order.
Example:
>HiCommandCLI AddExternalArrayGroup serialnum=14053 model=USP_Vportname= CL1-H, CL5-Hexternalwwn= 50.06.0E.80.04.36.E5.00, 50.06.0E.80.04.36.E5.01
externallun= 100, 101 RESPONSE:
An instance of StorageArray
(… omitted …)
List of 2 ExternalPathInfo elements:
An instance of ExternalPathInfo
objectID=*****
externalwwn=50.06.0E.80.04.36.E5.00
...
priority=1
An instance of ExternalPathInfo
objectID=*****
externalwwn=50.06.0E.80.04.36.E5.01
...
priority=2
Primary path
Alternate path
Priority attribute is added to ExternalPathInfo instance to identify
the primary or alternate path.
32
Enhancement Support – Hitachi Adaptable Modular Storage 2000 family and Hitachi Simple Modular Storage
• As the Adaptable Modular Storage 2000 family and Simple Modular Storage support SAS 450GB disk drives, Device Manager reports SAS in the type.
• CLI reports SAS disk type in the following commands,
– GetStorageArray(subtarget=LDEV)
– GetStorageArray(subtarget=PDEV)
Volumes can be filtered by SAS type.
SAS is reported on the type column.
4
Value
The value indicates SAS drivediskType
DescriptionAttribute
CLI output attribute
>HiCommandCLI GetStorageArray subtarget=LDEV
model=AMS2100 serialnum=83000081
RESPONSE:
An instance of StorageArray
(Attributes of StorageArray are omitted)
List of 230 Ldev elements:
An instance of LDEV
objectID=*****
devNum=0
displayName=30
...
diskType=4
...
Sample: GetStorageArray (subtarget=LDEV)
33
• Restriction for SSL communication
– Systems support SSL in microcode version V4(x840/x or later), but Device Manager V6.1 does not support SSL to communicate with the Adaptable
Modular Storage 2000 family and Simple Modular Storage.
– Device Manager requires non-SSL port to manage them.
Enhancement Support – Hitachi Adaptable Modular Storage 2000 family and Hitachi Simple Modular Storage
34
Operating System Support
The following operating systems are newly supported.
Note: Provisioning Manager server, web client, and agent support charts are same as HDvM.
Supportedn/aNEWNEWNEWWindows Vista SP1
Supportedn/aNEWNEWNEWWindows Server 2008
NEWn/an/an/aNEWVMWare ESX Server 3.x
(Guest OS: Windows)
NEWn/aNEWNEWNEW
Red Hat Enterprise Linux 5.2,
Red Hat Enterprise Linux Advanced Platform 5.2
n/an/aNEWNEWNEWWindows XP SP3
NEWn/aSupportedSupportedNEWRed Hat Enterprise Linux
AS/ES 4.6
CLIEXServer AgentCLIWeb Client
ClientOperating Systems
35
Web Browser Support
Note: Device Manager Provisioning Manager component web client support charts are same as HDvM.
The following web browsers are supported.
Solaris 10
HP-UX 11i v3
Firefox 2.0
Red Hat Linux 5.2
Operating Systems
Firefox 3.0
Web Browsers
The following web browser is withdrawn from the support.
Solaris 9
Operating Systems
Mozilla 1.4
Web Browsers
Questions/Discussion
36
37
Upcoming WebTech Seminars
• Upcoming Microsoft Exchange Series
– Archive: Optimizing your storage infrastructure for Microsoft Exchange Archiving with the Hitachi Content Archive Platform, March 11, 2009, 9 am PT
– Manage: Optimal Storage Performance for Microsoft Exchange using Hitachi Tuning Manager, April 15, 2009, 9 am PT
• Other Sessions
– Adding Search to NetApp Environments, February 25, 2009, 9 am PT
– Best Practices for Hitachi Storage Capacity Reporter, Powered by Aptare®to Increase Storage Utilization and Decrease Costs, March 18, 2009, 9 am PT
– The Economics of Storage Virtualization, March 25, 2009, 9 am PT
• Please check www.hds.com/webtech for:
– Link to the recording, the presentation, and Q&As (available next week)
– Schedule and registration for upcoming WebTech sessions
Thank You
38