86

Important Notice - RAM Fiberglass

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Important Notice - RAM Fiberglass
Page 2: Important Notice - RAM Fiberglass

Important Notice

The information and recommendations presented in this product catalog

are based on data reasonably believed to be reliable. RAM Fiberglass, Inc.

makes no representation or warranty, express or implied, including warran-

ties of merchantability or fitness for purpose, as to the accuracy, adequacy or

completeness of the information or recommendation contained herein. RAM

Fiberglass, Inc, assumes no liability whatsoever in connection with this

information or recommendations it contains.

Page 3: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-9885

About RAM Fiberglass, Inc.

Thank you for considering RAM Fiberglass, Inc. for your fiberglass piping requirements. We hope you find our catalog to be one of the most complete in the industry.

Since 1973, RAM Fiberglass, Inc. has supplied fiberglass pipe and fittings to the petroleum, chemical process, power, marine and municipal markets. Our standard product line of pipe and fittings is manufactured using a premium grade of vinyl ester resin pigmented dark gray which will handle most service environments to 200°F. We offer a premium grade high temperature vinyl ester resin system for services to 250°F. We also offer a complete line of epoxy fittings. Please consult RAM Fiberglass, Inc. for the resin system which best suits your service environment.

RAM Fiberglass, Inc. pipe fittings are manufactured in sizes ½” to 36” at our facility in Chino, California. Standard products are offered with a 40 mil corrosion resistant inner liner. This 0.040-inch inner liner will provide good chemical resistance and mild abrasion resistance in most applications. Our products are also available with a highly corrosion resistant 110 mil “SPI” liner in accordance with National Bureau of Standards (NBS) “Voluntary Product Standard PS 15-69”. For highly abrasive services we offer all internal corrosion resistant liners with an abrasion resistant (ABR) additive. All products are finished with a UV inhibitor and wax coat in the exterior layer.

Several joining systems are offered to facilitate pipe and fitting assembly. Standard joining systems for pipe and fittings ½-inch to 12-inch diameter are adhesive bonded bell and spigot, flanged or plain-end for butt-and-wrap joining. Joining systems for pipe sizes greater than 12-inch are plain-end for butt-and-wrap joining or flanged. Threaded pipe fittings and adapters are also available in sizes to 8-inch. Choosing the right joining system can save valuable field labor dollars. Please consult RAM Fi-berglass, Inc. for assistance in selecting the right joining technique for your project.

The products offered in this catalog are designed for an internal operating pressure of 150 psi unless noted otherwise. Our recommended maximum test pressure on a piping system is 1 ½ times the actual operating pressure of the piping system using water as the test media.

In addition to manufacturing, RAM Fiberglass, Inc. offers complete shop prefabrication services, field repairs and installation of fiberglass pipe and pipe fittings. If we can be of service in these areas please contact us for a quotation.

We at RAM Fiberglass, Inc. are dedicated to service you in your fiberglass pipe and fittings requirements. From standard off-the-shelf items to custom fittings, special fabrications and field installation, we are sure you will find our manufacturing, sales and engineering staff and field service crews responsive to your individual requirements.

Page 4: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-9885

In addition to our complete line of filament-wound FRP pipe and fittings, RAM Fiberglass, Inc. is pleased to offer the following specialized services: • Field Maintenance and Repair of FRP Pipe Systems

and Equipment

• Shop Prefabrication Service—Pipe Sizes To 48”

Diameter

• Field Installation of Pipe and Piping Systems

Please inquire if you have special shapes, non-standard dimensions, fabrication of isometrics, or field repairs.

(909) 627-9822

California State Contractors License # 511853

Page 5: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-9885i

TABLE OF CONTENTS

DESCRIPTION PAGECOUPLINGS .........................................................................................................................................1

ADAPTERS ...........................................................................................................................................3

NIPPLES ...............................................................................................................................................4

BUSHINGS ............................................................................................................................................5

CAPS.....................................................................................................................................................6

PLUGS ..................................................................................................................................................7

FLANGES .............................................................................................................................................8

90 DEGREE ELBOWS..........................................................................................................................21

SPECIAL ANGLE ELBOWS .................................................................................................................24

45 DEGREE ELBOWS..........................................................................................................................25

TEES .....................................................................................................................................................28

REDUCING TEES .................................................................................................................................33

TAPERED BODY REDUCERS .............................................................................................................36

SADDLES .............................................................................................................................................46

CROSSES .............................................................................................................................................57

LATERALS ............................................................................................................................................59

WYES ....................................................................................................................................................61

P-TRAPS ...............................................................................................................................................63

FLOOR DRAIN ......................................................................................................................................64

BUTT-AND-WRAP FIELD WELD KITS/ADHESIVE KITS ...................................................................65

END DOMES .........................................................................................................................................66

ENGINEERING ..................................................................................................................................... Appendices

TERMS AND CONDITIONS OF SALE .................................................................................................80

Page 6: Important Notice - RAM Fiberglass
Page 7: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-98851

INNER SECTION (2

)

OUTER SECTIONS (2

)

L

HOSE CLAMP

1-R

ASSEMBLED VIEW

Fig #1 Coupling, Pipe Bell-End

1/2 2.00 0.87 0.84 0.2 3/4 2.25 1.00 1.05 0.2 1 2.37 1.06 1.31 0.3 1-1/2 3.00 1.37 1.90 0.4 2 3.87 1.81 2.37 0.6 2-1/2 3.87 1.81 2.88 0.8 3 3.87 1.81 3.50 1.2 4 3.87 1.81 4.50 1.6 6 4.75 2.25 6.62 2.6 8 5.25 2.50 8.62 3.8 10 5.75 2.75 10.75 4.4 12 6.25 3.00 12.75 5.0 14 6.25 3.00 14.56 8.0 16 7.25 3.50 16.56 10.0 18 7.75 3.75 18.56 14.0 20 9.75 4.75 20.62 19.0 24 9.75 4.75 24.57 25.0 Standard couplings are designed to fit pipe with O.D.’s as shown. Couplings to fit pipe with other O.D.’s are available. Please state pipe O.D. when ordering couplings. No returns allowed on sizes 14” and larger.

Size(in.)

“A”(in.)

“B”(in.)

Pipe O.D.(in.)

Weight(lb.)

1/2 2.50 1-3oz 0.3 3/4 2.50 1-3oz 0.4 1 2.62 1-3oz 0.4 1-1/2 3.25 1-3oz 0.8 2 4.00 1-5oz 1.1 2-1/2 4.00 1-5oz 1.3 3 4.00 1-5oz 1.6 4 4.00 1-5oz 2.0 6 4.75 2-5oz 3.3 8 5.25 3-5oz 4.7 10 5.75 4-5oz 6.4 12 6.25 5-5oz 8.2 14 6.25 5-5oz 8.9 16 7.25 7-5oz 11.8 18 7.75 8-5oz 14.8 20 9.75 11-5oz 23.0 24 9.75 12-5oz 33.2 Maintenance coupling kit includes inner and outer 180-degree sec-tions and hose clamps. Adhesive kits are sold separately. 1/2” to 12” maintenance couplings are rated for 150 psi hydrostaticpressure. Maintenance couplings 14” and larger are rated for 50 psi. Rated pressure based on PSX-34 or equivalent adhesive. No returns allowed on sizes 14” and larger.

Size(in.)

StandardCouplingLength

“L”( in.)

AdhesiveKits

Required(no.)

Weight(lb.)

COUPLINGS

Fig #1-R Coupling, Repair (Maintenance)

1

A

BB

Page 8: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-98852

Fig #2-LCoupling, Threaded Long

1/2 4.43 1.13 0.33/4 4.43 1.38 0.31 4.43 1.63 0.41-1/4 4.43 2.00 0.61-1/2 4.43 2.25 0.72 4.43 2.75 0.92-1/2 4.43 3.38 1.13 4.43 4.00 1.24 4.43 5.00 1.66 4.18 7.25 2.68 4.50 9.50 3.8

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

Fig #2-L/2Coupling, Threaded Half

1/2 2.18 0.23/4 2.18 0.21 2.18 0.21-1/4 2.18 0.31-1/2 2.18 0.42 2.18 0.52-1/2 2.18 0.63 2.18 0.64 2.18 0.86 2.06 1.38 2.21 1.9

Size(in.)

“A”(in.)

Weight(lb.)

Fig #2-XLCoupling, Threaded Extra Long

1/2 6.00 0.43/4 6.00 0.41 6.00 0.41-1/4 6.00 0.61-1/2 6.00 0.82 6.00 1.22-1/2 6.00 1.53 6.00 1.74 6.00 2.06 6.00 3.08 6.00 4.0

Size(in.)

“A”(in.)

Weight(lb.)

2-L

A

NPTB

2L/2

A

NPT

2-XL

A

NPT

Page 9: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-98853

Fig #3Adapter, Female, Bell x Thread

1/2 2.00 0.87 0.13/4 2.12 1.00 0.11 2.31 1.06 0.21-1/2 2.62 1.37 0.42 3.25 1.81 0.62-1/2 3.81 1.81 0.93 3.81 1.81 1.24 3.93 1.81 1.66 4.50 2.25 2.68 5.00 2.50 3.8

Fig #2-XL/2Coupling, Threaded Extra Long, Half

1/2 3.00 0.23/4 3.00 0.21 3.00 0.21-1/4 3.00 0.31-1/2 3.00 0.42 3.00 0.62-1/2 3.00 0.73 3.00 0.84 3.00 1.06 3.00 1.28 3.00 2.0

Fig #2-SCoupling, Threaded Short

1/2 2.25 0.23/4 2.25 0.21 2.50 0.21-1/4 2.50 0.31-1/2 2.75 0.42 3.00 0.6

Size(in.)

Size(in.)

Size(in.)

“A”(in.)

“A”(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

Weight(lb.)

Weight(lb.)

2XL/2

A

NPT

2S

A

BNPT

3

A

B

NPT

ADAPTERS

Page 10: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-98854

Fig #4Adapter, Male, Bell x Thread

1 2.50 .87 1.00 0.31-1/2 2.62 1.37 1.50 0.42 3.25 1.81 1.87 0.63 3.62 1.81 2.93 1.24 3.75 1.81 3.87 1.66 4.62 2.25 5.93 2.68 5.75 2.50 7.93 3.810 5.81 2.75 10.00 4.4

Fig #6Nipple, Threaded Pipe

1/2 3” 0.62 0.33/4 3” 0.75 0.31 3” 1.00 0.31-1/4 3” 1.12 0.31-1/2 3” 1.50 0.52 3” 1.87 0.72-1/2 6” 2.50 1.03 6” 3.00 1.24 6” 4.00 1.46 6” 6.00 2.1 Nipple lengths and sizes other than shown are available on request. Maximum length is 12”. No returns allowed on non-standard lengths.

Size(in.)

Size(in.)

“A”(in.)

“A”Std. Length

(in.)

“B”(in.)

“B”(in.)

“C”(in.)

Weight(lb.)

Weight(lb.)

Fig #5Adapter, Grooved, Bell x Victaulic

2 3.25 1.81 1.87 0.63 3.62 1.81 2.93 1.24 3.75 1.81 3.87 1.66 4.62 2.25 5.93 2.68 5.75 2.50 7.93 3.810 5.81 2.75 10.00 4.4 Fig #5 Adapters fit victaulic couplings Style 76 and 77.

Size(in.)

“A”(in.)

“B”(in.)

“C”(in.)

Weight(lb.)

4

A

B

C

NPT

5

A

B

C

6

A

B

NPT

NIPPLES

Page 11: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-98855

Fig #7Nipple, Spigot x Male Thread Pipe

1/2 3” 0.84 0.33/4 3” 1.05 0.31 3” 1.32 0.31-1/4 3” 1.62 0.31-1/2 3” 1.90 0.52 3” 2.38 0.72-1/2 6” 2.88 1.03 6” 3.50 1.24 6” 4.50 1.46 6” 6.62 2.1 Nipple lengths and sizes other than shown are available on request. Maximum length is 12”. No returns allowed on non-standard lengths.

Size(in.)

“A”Std. Length

(in.)“B”(in.)

Weight(lb.)

Fig #8Nipple, Pipe

1/2 1.87 0.13/4 2.12 0.11 2.25 0.11-1/2 2.62 0.22 3.75 0.42-1/2 3.75 0.53 3.75 0.54 3.75 0.76 4.62 1.28 5.12 1.710 5.62 2.812 6.12 3.2

Longer lengths and larger sizes available on request.

Fig #9Bushing, Reducing

1 1.06 1/2 thru 3/41-1/2 1.25 1/2 thru 12 1.81 1/2 thru 1-1/22-1/2 1.81 1/2 thru 23 1.81 1/2 thru 2-1/24 1.81 1/2 thru 36 2.25 1/2 thru 58 2.50 1/2 thru 610 2.75 1/2 thru 812 3.00 1/2 thru 10

Larger sizes available on request. Bushings 6” and larger notrecommended for pressure greater than 50 psi. Eccentric reducingbushings are also available on request.

Size(in.)

Size(in.)

“A”(in.)

“A”(in.)

Weight(lb.)

“B”(in.)

7

A

B

NPT

8

A

9

A

B

BUSHINGS

Page 12: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-98856

Fig #10Bushing, Threaded Reducing

1 1.06 1/2 thru 3/41-1/2 1.25 1/2 thru 1-1/42 1.81 1/2 thru 1-1/22-1/2 1.81 1/2 thru 23 1.81 1/2 thru 2-1/24 1.81 1/2 thru 36 2.25 1/2 thru 48 2.50 1/2 thru 610 2.75 1/2 thru 812 3.00 1/2 thru 8

Larger sizes available on request. Stainless steel bushings available on special order. Bushings 6” and larger not recommended for pressure greater than 50 psi.

Size(in.)

“A”(in.)

“NPT”(in.)

Fig #11Cap, Pipe

1 2.00 1.06 0.61-1/2 2.25 1.37 0.82 2.75 1.81 1.02-1/2 3.00 1.81 1.33 3.00 1.81 1.54 3.00 1.81 2.56 4.00 2.25 7.08 4.50 2.50 12.010 5.00 2.75 17.212 5.50 3.00 24.2

For pipe caps larger than 12”, refer to Fig.# 99, End Domes.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

Fig #11-TCap, Threaded Pipe

1 2.50 0.61-1/2 2.62 0.82 2.75 1.02-1/2 3.50 1.33 4.00 1.54 4.00 2.56 5.00 4.0

Size(in.)

“A”(in.)

Weight(lb.)

10

A

NPT

11

A

B

11-T

NPT

A

CAPS

Page 13: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-98857

Fig #12Plug, Pipe

1/2 0.88 0.23/4 1.00 0.21 1.06 0.31-1/2 1.37 0.42 1.50 0.42-1/2 1.62 0.53 1.62 0.74 1.75 1.8

Plugs fit RAM pipe I.D. State pipe I.D. or manufacturer if not RAM pipe. Refer to Fig.#11 for sizes larger than 4”.

Fig #13Plug, Fitting

1/2 0.87 0.23/4 1.00 0.21 1.06 0.31-1/2 1.37 0.42 1.81 0.42-1/2 1.81 0.53 1.81 0.74 1.81 1.86 2.25 4.48 2.50 8.210 2.75 13.212 3.00 18.8

Fitting plug fits RAM fitting socket. Fitting plugs 6” and larger not recommended for pressure greater than 50 psi.

Fig #13-TPlug, Threaded Fitting

1/2 1.50 0.33/4 1.50 0.51 1.50 0.61-1/2 1.50 0.82 1.62 1.02-1/2 1.75 1.33 1.75 1.54 2.25 2.56 2.25 4.08 2.75 6.0

Sizes 3” and larger are made with a recessed head unless otherwise specified.

Size(in.)

Size(in.)

Size(in.)

“A”(in.)

“A”(in.)

“A”(in.)

Weight(lb.)

Weight(lb.)

Weight(lb.)

12

A

FITSRAMPIPE I.D.

13

A

FITSRAM

FITTING SOCKET

13-T

NPT

PLUGS

Page 14: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-98858

Fig #14Flange, Filament-Wound 300 lb. Socket

1 4.88 3.50 4 3/4 1.18 .12 0.91-1/2 6.13 4.50 4 7/8 1.37 .12 1.22 6.50 5.00 8 3/4 1.50 .12 2.22-1/2 7.50 5.88 8 7/8 1.50 .12 3.23 8.25 6.62 8 7/8 1.62 .12 4.54 10.00 7.87 8 7/8 1.93 .12 6.86 12.50 10.62 12 7/8 2.37 .12 9.08 15.00 13.00 12 1 2.62 .12 16.010 17.50 15.25 16 1-1/8 3.00 .25 20.012 20.50 17.75 16 1-1/4 3.25 .25 28.014 23.00 20.25 20 1-1/4 3.25 .25 33.016 25.50 22.50 20 1-3/8 3.75 .25 39.0

Flange drilled to ANSI B16.5, 300 lb. Please refer to Appendix B for flange assembly instructions. This flange is rated for 150 psi maximum operating pressure.

Size(in.)

“A”Flg. O.D.

(in.)

“D”Dia. Holes

(in.)

“B”Bolt Circle

(in.)

“E”Flg. Thk.

(in.)

“C”Holes(no.)

“G”(in.)

Weight(lb.)

14

DC

G A

B

E

FLANGES

Page 15: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-98859

Fig #15Flange, Filament-Wound 150 lb. Socket

1/2 3.50 2.37 4 5/8 0.56 1.00 .12 0.33/4 3.87 2.75 4 5/8 0.56 1.00 .12 0.41 4.25 3.12 4 5/8 0.75 1.18 .12 0.51-1/4 4.63 3.50 4 5/8 0.75 1.25 .12 0.61-1/2 5.00 3.87 4 5/8 0.81 1.37 .12 0.62 6.00 4.75 4 3/4 0.81 1.48 .12 1.52-1/2 7.00 5.50 4 3/4 1.00 1.50 .12 2.33 7.50 6.00 4 3/4 1.12 1.62 .12 3.04 9.00 7.50 8 3/4 1.18 2.00 .12 4.05 10.00 8.50 8 7/8 1.37 2.00 .12 5.56 11.00 9.50 8 7/8 1.56 2.37 .12 6.08 13.50 11.75 8 7/8 1.75 2.62 .12 10.010 16.00 14.25 12 1 2.12 3.00 .25 14.012 19.00 17.00 12 1 2.25 3.25 .25 21.014 21.00 18.75 12 1-1/8 2.37 3.25 .25 29.016 23.50 21.25 16 1-1/8 2.75 3.75 .25 40.018 25.00 22.75 16 1-1/4 3.00 4.00 .25 45.020 27.50 25.00 20 1-1/4 4.00 5.00 .25 70.024 32.00 29.50 20 1-3/8 4.25 5.00 .25 100.030 38.75 36.00 28 1-3/8 3.25 4.37 .31 105.036 46.00 42.75 32 1-5/8 3.62 4.62 .37 160.0 Flange drilled to ANSI B16.5, 150lb. Please refer to Appendix B for flange assembly instructions.

Size(in.)

“A”Flg. O.D.

(in.)

“D”Dia. Holes

(in.)

“B”Bolt Circle

(in.)“E”(in.)

“F”(in.)

“C”Holes(no.)

“G”(in.)

Weight(lb.)

15

A

B

F

E

DC

G

Page 16: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988510

Fig #15-AFlange, Filament-Wound 150 lb. Stub

1/2 6.0 0.56 0.53/4 6.0 0.56 0.61 6.0 0.75 0.71-1/2 6.0 0.81 0.92 6.0 0.81 1.82-1/2 6.0 1.00 2.53 6.0 1.12 3.54 6.0 1.18 5.05 8.0 1.37 6.06 8.0 1.56 7.08 8.0 1.75 13.010 10.0 2.12 17.012 10.0 2.25 24.014 12.0 2.37 44.016 12.0 2.75 54.018 12.0 3.00 64.020 12.0 4.00 90.024 12.0 4.25 142.030 15.0 3.25 150.036 15.0 3.62 195.0

Flange drilled to ANSI B16.5, 150lb. See Fig. #15 for number, position and size of bolt holes. Please refer to Appendix B for flange assembly instructions.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

15-A

AB

Page 17: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988511

Fig #15-HDFlange, Filament-Wound 150 lb. Heavy Duty Socket

1/2 3.50 2.37 4 5/8 1.00 .12 0.43/4 3.87 2.75 4 5/8 1.00 .12 0.61 4.25 3.12 4 5/8 1.18 .12 0.81-1/2 5.00 3.87 4 5/8 1.37 .12 1.02 6.00 4.75 4 3/4 1.48 .12 2.02-1/2 7.00 5.50 4 3/4 1.50 .12 3.03 7.50 6.00 4 3/4 2.00 .12 4.04 9.00 7.50 8 3/4 2.00 .12 6.06 11.00 9.50 8 7/8 2.37 .12 9.58 13.50 11.75 8 7/8 2.62 .12 15.010 16.00 14.25 12 1 3.00 .25 22.012 19.00 17.00 12 1 3.25 .25 34.514 21.00 18.75 12 1-1/8 3.25 .25 40.016 23.50 21.25 16 1-1/8 3.75 .25 55.518 25.00 22.75 16 1-1/4 4.00 .25 58.520 27.50 25.00 20 1-1/4 5.00 .25 86.524 32.00 29.50 20 1-3/8 5.00 .25 109.530 38.75 36.00 28 1-3/8 4.37 .31 128.536 46.00 42.75 32 1-5/8 4.67 .37 185.0 Flange drilled to ANSI B16.5, 150 lb. Please refer to Appendix B for flange assembly instructions.

Size(in.)

“A”Flg. O.D.

(in.)

“D”Dia. Holes

(in.)

“B”Bolt Circle

(in.)

“E”Flg. Thk.

(in.)

“C”Holes(no.)

“G”(in.)

Weight(lb.)

15-HD

DC

G A

E

B

Page 18: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988512

Fig #15-SFlange, Filament-Wound 150 lb. Spacer

1/2 .253/4 .251 .251-1/2 .252 .252-1/2 .253 .254 .255 .256 .258 .2510 .2512 .2514 .2516 .2518 .2520 .2524 .2530 .2536 .25

RAM Flange Spacers are designed to bolt between two flanges where a separation exists due to equipment changes or field repairs. Flange spacers are manufactured to your specifications on size, thickness and bolt hole pattern. Flange spacers are rated for 150 psi. No returns allowed.

Size(in.)

“T”Min. Thk.

(in.)

15-S

CORROSIONRESISTANTLINER

Page 19: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988513

Fig #15-VSFlange, Filament-Wound 150 lb. Van Stone Socket

1 4.25 3.12 4 5/8 0.75 1.50 .12 1.251-1/2 5.00 3.87 4 5/8 0.81 1.62 .12 1.802 6.00 4.75 4 3/4 0.81 1.62 .12 2.502-1/2 7.00 5.50 4 3/4 1.00 2.00 .12 3.503 7.50 6.00 4 3/4 1.12 2.25 .12 3.754 9.00 7.50 8 3/4 1.00 2.12 .12 5.005 10.00 8.50 8 7/8 1.38 2.75 .12 6.406 11.00 9.50 8 7/8 1.38 3.12 .12 7.508 13.50 11.75 8 7/8 1.50 3.00 .12 12.4010 16.00 14.25 12 1 2.00 4.00 .25 17.5012 19.00 17.00 12 1 2.12 4.25 .25 26.3014 21.00 18.75 12 1-1/8 2.37 4.75 .25 36.0016 23.50 21.25 16 1-1/8 2.75 5.50 .25 50.0018 25.00 22.75 16 1-1/4 3.00 6.00 .25 52.0020 27.50 25.00 20 1-1/4 4.00 8.00 .25 85.0024 32.00 29.50 20 1-3/8 4.25 8.50 .25 120.0030 Special Order 36 Special Order Van-Stone flanges allow orientation of bolt holes on any centerline due to the loose flange ring. Van Stone flanges are drilled to ANSI B16.5, 150lb. Please refer to Appendix B for flange assembly instructions.

Size(in.)

“A”Flg. O.D.

(in.)

“D”Dia. Holes

(in.)

“B”Bolt Circle

(in.)“E”(in.)

“F”(in.)

“C”Holes(no.)

“G”(in.)

Weight(lb.)

15-VS

G

DC

A

B

E

F

Page 20: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988514

Fig #15-A-VSFlange, Filament-Wound 150 lb. Van-Stone Stub

1 6.00 1.50 1.41-1/2 6.00 1.62 2.22 6.00 1.62 2.92-1/2 6.00 2.00 3.03 6.00 2.25 4.44 6.00 2.38 6.05 8.00 2.75 8.46 8.00 3.12 9.58 8.00 3.50 15.210 10.00 4.00 21.812 10.00 4.25 31.414 12.00 4.75 43.416 12.00 5.50 59.518 12.00 6.00 76.320 12.00 8.00 100.824 12.00 8.50 141.230 Special Order 36 Special Order

Flange drilled to ANSI B16.5, 150lb. See Fig.# 15-VS for number, size and position of bolt holes. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

15-A-VS

G

DC

B

A

Page 21: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988515

Fig #15-25Flange, Filament-Wound 25 lb. Socket

6 11.00 9.50 8 5/8 .56 1.31 .12 4.08 13.50 11.75 8 5/8 .88 1.75 .12 6.010 16.00 14.25 12 5/8 1.00 1.88 .12 8.012 19.00 17.00 12 5/8 1.00 2.00 .12 12.014 21.00 18.75 12 5/8 .88 1.88 .25 15.016 23.50 21.25 16 5/8 1.00 2.00 .25 19.018 25.00 22.75 16 5/8 1.00 2.00 .25 25.020 27.50 25.00 20 3/4 1.25 2.25 .25 32.024 32.00 29.50 20 3/4 1.50 2.50 .25 44.030 38.75 36.00 28 3/4 1.50 2.50 .31 55.036 46.00 42.75 32 3/4 1.75 2.75 .37 80.0 Flanges rated for 25 psi are designed to be bolted to flat face flanges only. If bolting to a raised face flange or valve an annular spacer ring must be used. The 25 psi flange is designed for low pressure applications such as tank outlets, man-ways and duct flanges. Flange drilling to ANSI B16.5, 150lb. is also available, please specify on order. Please refer to Appendix B for flange assembly instructions.

Size(in.)

“A”Flg. O.D.

(in.)

“D”Dia. Holes

(in.)

“B”Bolt Circle

(in.)“E”(in.)

“F”(in.)

“C”Holes(no.)

“G”(in.)

Weight(lb.)

15-25

A

B

F

E

DC

G

Page 22: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988516

Fig #15-A-25Flange, Filament-Wound 25 lb. Stub

6 8.00 0.56 7.08 8.00 0.87 10.010 10.00 1.00 13.012 10.00 1.00 19.014 12.00 1.00 25.016 12.00 1.00 30.018 12.00 1.13 39.020 12.00 1.25 48.024 12.00 1.50 64.030 15.00 1.50 80.036 15.00 1.75 110.0

Flanges rated for 25 psi are designed to be bolted to flat face flanges only. Ifbolting to a raised face flange or valve an annular spacer ring must be used.The 25 psi flange is designed for low pressure applications such as tank outlets, manways and duct flanges. Flange drilling to ANSI B16.5, 150lb. is also available, please specify on order. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

Fig #15-VS-25Flange, Filament-Wound 25 lb. Van-Stone Socket

6 11.00 9.50 8 5/8 .56 1.31 .12 6.08 13.50 11.75 8 5/8 .88 1.75 .12 9.010 16.00 14.25 12 5/8 1.00 2.00 .12 12.012 19.00 17.00 12 5/8 1.00 2.00 .12 18.014 21.00 18.75 12 5/8 1.00 2.00 .25 22.516 23.50 21.25 16 5/8 1.00 2.00 .25 28.518 25.00 22.75 16 5/8 1.13 2.25 .25 37.520 27.50 25.00 20 3/4 1.25 2.50 .25 48.524 32.00 29.50 20 3/4 1.50 3.00 .25 66.030 Special Order 36 Special Order

Van Stone flanges allow orientation of bolt holes on any centerline due to the loose flange ring. The 25 psi flange is designed for low pressure applications such as tank outlets, manways, and duct flanges. Flange drilling to ANSI B16.5 is also available, please specify on order. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”Flg. O.D.

(in.)

“D”Dia. Holes

(in.)

“B”Bolt Circle

(in.)“E”(in.)

“F”(in.)

“C”# Holes

(no.)“G”(in.)

Weight(lb.)

15-A-25

A

B

15-VS-25

A

B

DC

G

E

F

Page 23: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988517

Fig #15-A-VS-25Flange, Filament-Wound 25 lb. Van-Stone Stub

6 8.00 1.31 9.08 8.00 1.75 12.010 10.00 2.00 18.012 10.00 2.00 29.514 12.00 2.00 39.016 12.00 2.00 47.018 12.00 2.25 61.020 12.00 2.50 83.024 12.00 3.00 96.030 Special Order36 Special Order

Van Stone flanges allow orientation of bolt holes on any centerline due to the loose flange ring. The 25 psi flange is designed for low pressure applications such as tank outlets, manways, and duct flanges. Flange drilling to ANSI B16.5 is also available, please specify on order. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

Fig #16Flange, 150 lb. Blind

1/2 3.50 2.37 4 5/8 0.56 0.53/4 3.87 2.75 4 5/8 0.56 0.61 4.25 3.12 4 5/8 0.75 0.71-1/2 5.00 3.87 4 5/8 0.81 0.92 6.00 4.75 4 3/4 0.81 2.22-1/2 7.00 5.50 4 3/4 1.00 3.03 7.50 6.00 4 3/4 1.12 4.54 9.00 7.50 8 3/4 1.18 8.05 10.00 8.50 8 7/8 1.37 9.56 11.00 9.50 8 7/8 1.56 12.08 13.50 11.75 8 7/8 1.75 24.010 16.00 14.25 12 1 2.00 30.012 19.00 17.00 12 1 2.12 45.014 21.00 18.75 12 1-1/8 2.37 62.016 23.50 21.25 16 1-1/8 2.75 80.018 25.00 22.75 16 1-1/4 3.00 96.020 27.50 25.00 20 1-1/4 4.00 156.024 32.00 29.50 20 1-3/8 4.25 230.030 38.75 36.00 28 1-3/8 3.31 300.036 46.00 42.75 32 1-5/8 3.62 405.0 Flange drilled to ANSI B16.5, 150 lb. Please refer to Appendix B for flange assembly instructions. No returns allowed on sizes 14” and larger.

Size(in.)

“A”Flg. O.D.

(in.)

“D”Dia. Holes

(in.)

“B”Bolt Circle

(in.)“E”(in.)

“C”Holes(no.)

Weight(lb.)

15-A-VS-25

A

B

16

A

B

E

DC

Page 24: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988518

Fig #16-25Flange, 25 lb. Blind

6 11.00 9.50 8 5/8 0.56 11.08 13.50 11.75 8 5/8 0.87 14.410 16.00 14.25 12 5/8 1.00 18.012 19.00 17.00 12 5/8 1.00 27.014 21.00 18.75 12 5/8 1.00 37.216 23.50 21.25 16 5/8 1.00 48.018 25.00 22.75 16 5/8 1.13 57.620 27.50 25.00 20 3/4 1.25 93.624 32.00 29.50 20 3/4 1.50 138.030 38.75 36.00 28 3/4 1.50 180.036 46.00 42.75 32 3/4 1.75 243.0 Flanges rated for 25 psi are designed to be bolted to flat face flanges only. If bolting to a raised face flange or valve anannular spacer ring must be used. The 25 psi flange is designed for low pressure applications such as tank outlets,man-ways and duct flanges. Flange drilling to ANSI B16.5, 150lb. is also available, please specify on order. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”Flg. O.D.

(in.)

“D”Dia. Holes

(in.)

“B”Bolt Circle

(in.)“E”(in.)

“C”Holes(no.)

Weight(lb.)

Fig #17Flange, Filament-Wound 150 lb. NPT Threaded

1 4.25 3.12 4 5/8 0.75 1.18 1/2 thru 11-1/2 5.00 3.87 4 5/8 0.81 1.37 1/2 thru 1-1/22 6.00 4.75 4 3/4 0.81 1.48 1/2 thru 22-1/2 7.00 5.50 4 3/4 1.00 1.50 1/2 thru 2-1/23 7.50 6.00 4 3/4 1.12 1.65 1/2 thru 34 9.00 7.50 8 3/4 1.18 2.00 1/2 thru 45 10.00 8.50 8 7/8 1.37 2.00 1/2 thru 46 11.00 9.50 8 7/8 1.56 2.37 1/2 thru 68 13.50 11.75 8 7/8 1.75 2.62 1/2 thru 810 16.00 14.25 12 1 2.12 3.00 1/2 thru 812 19.00 17.00 12 1 2.25 3.25 1/2 thru 8

Flange drilled to ANSI B16.5, 150lb. Stainless steel bushings available on request. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”Flg. O.D.

(in.)

“D”Dia. Holes

(in.)

“B”Bolt Circle

(in.)“E”(in.)

“F”(in.)

“C”Holes(no.)

“G”NPT Thread

(in.)

16-25

A

B

E

DC

17

A

B

F

E

DC

G

Page 25: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988519

Fig #18Flange, Filament-Wound 150 lb. Reducing Socket

1 4.25 3.12 4 5/8 0.75 1.18 1/2 thru 3/41-1/2 5.00 3.87 4 5/8 0.81 1.37 1/2 thru 1-1/42 6.00 4.75 4 3/4 0.81 1.48 1/2 thru 1-1/22-1/2 7.00 5.50 4 3/4 1.00 1.50 1/2 thru 23 7.50 6.00 4 3/4 1.12 1.65 1/2 thru 2-1/24 9.00 7.50 8 3/4 1.18 2.00 1/2 thru 35 10.00 8.50 8 7/8 1.37 2.00 1/2 thru 46 11.00 9.50 8 7/8 1.56 2.37 1/2 thru 58 13.50 11.75 8 7/8 1.75 2.62 1/2 thru 610 16.00 14.25 12 1 2.12 3.00 1/2 thru 812 19.00 17.00 12 1 2.25 3.25 1/2 thru 1014 21.00 18.75 12 1-1/8 2.37 3.25 1/2 thru 1216 23.50 21.25 16 1-1/8 2.75 3.75 1/2 thru 1418 25.00 22.75 16 1-1/4 3.00 4.00 1/2 thru 1620 27.50 25.00 20 1-1/4 4.00 5.00 1/2 thru 1824 32.00 29.50 20 1-3/8 4.25 5.00 1/2 thru 2030 38.75 36.00 28 1-3/8 3.25 4.37 1/2 thru 2436 46.00 42.75 32 1-5/8 3.62 4.62 1/2 thru 30 Flange drilled to ANSI B16.5, 150lb. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”Flg. O.D.

(in.)

“D”Dia. Holes

(in.)

“B”Bolt Circle

(in.)“E”(in.)

“F”(in.)

“C”Holes(no.)

“G”Nom.

Socket Dia. (in.)

18

A

B

F

E

DC

G

Page 26: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988520

Fig #19Flange, Filament-Wound Orifice

1 4.25 3.12 4 5/8 1.62 2.31 1.01-1/2 5.00 3.87 4 5/8 1.75 2.50 1.12 6.00 4.75 4 3/4 2.00 2.68 2.82-1/2 7.00 5.50 4 3/4 2.12 2.62 4.53 7.50 6.00 4 3/4 2.12 2.62 5.24 9.00 7.50 8 3/4 2.37 3.06 6.55 10.00 8.50 8 7/8 2.75 3.50 9.06 11.00 9.50 8 7/8 2.75 3.50 10.08 13.50 11.75 8 7/8 2.87 3.75 18.010 16.00 14.25 12 1 3.12 4.00 24.012 19.00 17.00 12 1 3.25 4.25 30.014 21.00 18.75 12 1-1/8 3.50 4.25 42.016 23.50 21.25 16 1-1/8 4.12 4.87 52.018 25.00 22.75 16 1-1/4 4.37 5.12 61.020 27.50 25.00 20 1-1/4 5.12 6.12 95.024 32.00 29.50 20 1-3/8 5.37 6.12 160.030 38.75 36.00 28 1-3/8 5.75 6.75 170.036 46.00 42.75 32 1-5/8 6.00 7.00 210.0 Flange drilled to ANSI B16.5, 150lb. Please refer to Appendix B for flange assembly instructions. Also available with double outlets on special order. No returns allowed.

Size(in.)

“A”Flg. O.D.

(in.)

“D”Dia. Holes

(in.)

“B”Bolt Circle

(in.)“E”(in.)

“F”(in.)

“C”Holes(no.)

Weight(lb.)

19

DC

A

B

F

E

7/8"

1/2" NPT 316S.S. NIPPLE

AND COUPLING

1 1/2"

Page 27: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988521

Fig #20-S/20-L90 Deg. Elbow, Short and Long Radius, Bell-End

1/2 0.50 N.A. 0.87 0.33/4 0.75 N.A. 1.00 0.41 1.00 1.50 1.06 0.71-1/2 1.50 2.25 1.25 1.02 2.00 3.00 1.81 1.52-1/2 2.50 N.A. 1.81 1.73 3.00 4.50 1.81 2.54 4.00 6.00 1.81 3.86 6.00 9.00 2.25 7.58 8.00 12.00 2.50 13.010 10.00 15.00 2.75 20.012 12.00 18.00 3.00 28.014 14.00 21.00 3.00 44.016 16.00 24.00 3.50 66.0 N.A. - Not available. Elbows 1/2” through 12” are rated for 150 psi. Elbows 14” and larger are rated for 100 psi. Higher pressure ratings are available. Bell-ends are designed to fit pipe with O.D.’s as shown in Fig.# 1. Please state O.D. or pipe manufacturer when ordering bell-end fittings for pipe with different O.D.’s.

Fig #21-S/21-L90 Deg. Elbow, Short and Long Radius, Plain-End

1/2 2.37 N.A. 0.33/4 2.67 N.A. 0.41 3.37 1.37 0.71-1/2 3.87 2.12 1.02 4.37 2.87 1.52-1/2 4.87 N.A. 1.73 5.37 4.37 2.54 6.37 5.87 3.86 7.87 11.37 7.58 8.87 13.87 13.010 10.87 16.37 20.012 11.87 18.87 28.014 14.00 21.00 36.016 16.00 24.00 46.018 18.00 27.00 57.020 20.00 30.00 70.024 24.00 36.00 93.030 N.A. 45.00 288.0

N.A. - Not available. Plain-end fittings are designed for butt-and-wrap joining. Butt-and wrap kits are available, please see Fig.# 90. Elbows 1” through 12” are rated for 150 psi. Elbows 14” and larger are rated for 100 psi. Higher pressure ratings are available. No returns allowed.

Size(in.)

Size(in.)

“A”Short Radius

20-S(in.)

“A”Short Radius

21-S(in.)

“AA”Long Radius

20-L(in.)

“AA”Long Radius

21-L(in.)

“B”Short & Long

Radius(in.)

Weight(lb.)

Weight(lb.)

90 DEGREE ELBOWS

AB

20-SSHORT RADIUS

B AA

20-LLONG RADIUS

21-SSHORT RADIUS

A

21-LLONG RADIUS

AA

Page 28: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988522

Fig #22-S/22-L90 Deg. Elbow, ANSI 150 lb. Flanged Short and Long Radius

1/2 2.50 N.A. 1.43/4 2.75 N.A. 1.71 3.50 5.00 2.21-1/2 4.00 6.00 3.42 4.50 6.50 5.52-1/2 5.00 N.A. 6.73 5.50 7.75 8.94 6.50 9.00 13.86 8.00 11.50 22.68 9.00 14.00 42.410 11.00 16.50 60.212 12.00 19.00 92.814 14.00 21.50 105.016 15.00 24.00 130.018 16.50 26.50 170.020 18.00 29.00 230.024 22.00 34.00 400.0

N.A. - Not available. Elbows 1/2” through 12” are rated for 150 psi. Elbows 14” and larger are rated for 100 psi. Higher pressure ratings are available. Fittings meet the centerline-to-flange-face dimension of ANSI B16.5, 150 lb. When ordering please specify Fig.# 22-S for short radius and Fig.# 22-L for long radius elbow per above dimensions. Elbows 14” through 24” are 3-piece mitered and overwound. Please refer to Appendix B for flange assembly instructions. No returns allowed on sizes 14” and larger.

Size(in.)

“A”Short Radius

22-S(in.)

“AA”Long Radius

22-L(in.)

Weight(lb.)

22-SSHORT RADIUS

A

22-LLONG RADIUS

AA

Page 29: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988523

Fig #23-S/23-L90 Deg. Elbow, ANSI 150 lb. Flange x Bell, Short and Long Radius

1/2 2.50 N.A. 0.50 N.A. 0.87 0.83/4 2.75 N.A. 0.75 N.A. 1.00 1.01 3.50 5.00 1.00 1.50 1.06 1.21-1/2 4.00 6.00 1.50 2.25 1.25 1.62 4.50 6.50 2.00 3.00 1.81 3.02-1/2 5.00 N.A. 2.50 N.A. 1.81 4.03 5.50 7.75 3.00 4.50 1.81 5.54 6.50 9.00 4.00 6.00 1.81 7.86 8.00 11.50 6.00 9.00 2.25 13.58 9.00 14.00 8.00 12.00 2.50 23.010 11.00 16.50 10.00 15.00 2.75 34.012 12.00 19.00 12.00 18.00 3.00 49.0 N.A. - Not available. Fittings meet the centerline-to-flange-face dimension of ANSI B16.5, 150 lb. When ordering please specify Fig. # 23-S for short radius and Fig. # 23-L for long radius elbow per above dimensions. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”Short Radius

23-S(in.)

“AA”Long Radius

23-L(in.)

“B”Short Radius

23-S(in.)

“BB”Long Radius

23-L(in.)

“C”Short &

Long Radius (in.)

Weight(lb.)

23-SSHORT RADIUS

B

A

C

C

23-LLONG RADIUS

BB

AA

Page 30: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988524

Fig #24-S/24-L90 Deg. Elbow, ANSI 150 lb. Flange x Plain-End, Short and Long Radius

1/2 2.50 N.A. 2.37 N.A. 0.83/4 2.75 N.A. 2.67 N.A. 1.01 3.50 N.A. 3.37 1.37 1.21-1/2 4.00 N.A. 3.87 2.12 1.62 4.50 N.A. 4.37 2.87 3.02-1/2 5.00 N.A. 4.87 N.A. 4.03 5.50 N.A. 5.37 4.37 5.54 6.50 N.A. 6.37 5.87 7.86 8.00 11.50 7.87 11.37 13.58 9.00 14.00 8.87 13.87 23.010 11.00 16.50 10.87 16.37 34.012 12.00 19.00 11.87 18.87 49.014 14.00 21.50 13.75 21.00 65.016 15.00 24.00 14.75 24.00 86.018 16.50 26.50 16.25 24.00 102.020 18.00 29.00 17.75 30.00 140.024 22.00 34.00 21.75 36.00 193.0 N.A. - Not available. Elbows 1/2” through 12” are rated for 150 psi. Elbows 14” and larger are rated for 100 psi. Higher pressure ratings are available. Plain-end is designed for butt-and-wrap joining. Please see Fig.# 90 for butt-and-wrap kits. Elbows 14” through 24” are 3-piece mitered and overwound. When ordering please specify Fig.# 24-S for short radius and FIG.# 24-L for long radius per above dimensions. Fittings meet the centerline-to-flange-face dimension of ANSI B16.5, 150 lb. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”Short Radius

24-S(in.)

“AA”Long Radius

24-L(in.)

“B”Short Radius

24-S(in.)

“BB”Long Radius

24-L(in.)

Weight(lb.)

Fig #2822-1/2 Degree Elbow, Special Angle, Bell-End

1 1.00 1.06 0.51-1/2 1.50 1.25 0.72 1.13 1.81 1.23 3.00 1.81 2.24 2.50 1.81 2.96 2.00 2.25 6.48 2.50 2.50 8.410 3.00 2.75 16.012 4.00 3.00 27.0

Angles other than shown are available. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

24-SSHORT RADIUS

B

A

24-LLONG RADIUS

BB

AA

28

22 1/2°

AB

SPECIAL ANGLE ELBOWS

Page 31: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988525

Fig #2930 Degree Elbow, Special Angle, Bell-End

1 1.00 1.06 0.51-1/2 1.50 1.25 0.72 2.00 1.81 1.23 3.00 1.81 2.24 2.50 1.81 2.96 2.50 2.25 6.48 3.38 2.50 8.410 4.00 2.75 16.012 5.00 3.00 27.0

Angles other than shown are available. No returns allowed.

Fig #3045 Degree Elbow, Bell-End

1 1.00 1.06 0.51-1/2 1.50 1.25 0.72 1.25 1.81 1.22-1/2 2.50 1.81 1.73 1.87 1.81 2.24 2.50 1.81 2.96 3.75 2.25 6.48 5.00 2.50 8.410 6.25 2.75 16.012 7.50 3.00 27.014 8.81 3.00 30.0016 10.00 3.50 36.00

Elbows 1” through 12” are rated for 150 psi. Elbows 14” and larger rated for 100 psi. Higher pressure ratings are available. Bell-ends are designed to fit pipe with O.D.’s as shown in Fig.# 1. Please state pipe O.D. or manufacturer when ordering bell-end fittings for pipe with different O.D.’s. No returns allowed on sizes 14” and larger.

Size(in.)

Size(in.)

“A”(in.)

“A”(in.)

“B”(in.)

“B”(in.)

Weight(lb.)

Weight(lb.)

29

30°

AB

30

B A

45 DEGREE ELBOWS

Page 32: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988526

Fig #3145 Degree Elbow, Plain-End

3/4 1.37 0.3 1 1.63 0.5 1-1/2 2.13 0.7 2 2.38 1.2 2-1/2 2.88 1.6 3 2.88 2.2 4 3.87 2.9 6 4.87 6.4 8 5.37 8.4 10 6.37 16.0 12 7.37 27.0 14 8.75 22.0 16 10.00 26.0 18 11.25 30.0 20 12.50 35.0 24 15.00 42.0

Plain-end fittings are designed for butt-and-wrap joining. Butt-and wrap kits are available, please see Fig.# 90. Elbows 3/4” through 12” are rated for 150 psi. Elbows 14” and larger are rated for 100 psi. Higher pressure ratings are available. No returns allowed.

Fig #3245 Degree Elbow, ANSI 150 lb. Flanged

3/4 1.50 1.7 1 1.75 2.0 1-1/2 2.25 3.0 2 2.50 5.0 2-1/2 3.00 7.5 3 3.00 9.0 4 4.00 13.0 6 5.00 22.0 8 5.50 35.0 10 6.50 50.0 12 7.50 82.0 14 7.50 94.0 16 8.00 112.0 18 8.50 134.0 20 9.50 185.0 24 11.00 342.0

Fittings meet the centerline-to-flange-face dimension of ANSI B16.5, 150 lb. Elbows 3/4” through 12” are rated for 150 psi. Elbows 14” and larger are rated for 100 psi. Higher pressure ratings areavailable. 14” to 24” elbows are 2-piece mitered and overwound. Please refer to Appendix B for flange assembly instructions. Main-tain end-point clearance of bolts on inside radius of 2”, 3” and 4” RAM flanged ANSI 45-degree elbows by using additional washers or shims under bolt heads as required. No returns allowed on sizes 14” and larger.

Size(in.)

Size(in.)

“A”(in.)

“A”(in.)

Weight(lb.)

Weight(lb.)

31

A

32

A

Page 33: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988527

Fig #3445 Degree Elbow, ANSI 150 lb. Flange x Plain-End

3/4 1.50 1.37 1.0 1 1.75 1.63 1.5 1-1/2 2.25 2.13 2.4 2 2.50 2.37 3.5 2-1/2 3.00 2.87 5.0 3 3.00 2.87 6.0 4 4.00 3.87 8.5 6 5.00 4.87 15.5 8 5.50 5.37 23.0 10 6.50 6.37 35.0 12 7.50 7.37 60.0 14 7.50 7.25 63.0 16 8.00 7.75 70.0 18 8.50 8.25 85.0 20 9.50 9.25 110.0 24 11.00 10.75 190.0

Elbows 3/4” through 12” are rated for 150 psi. Elbows 14” and larger are rated for 100 psi. Higher pressure ratings are available. Plain-end is designed for butt-and-wrap joining. Please see Fig.# 90 for butt-and-wrap kits. Fittings meet the centerline-to-flange-face dimension of ANSI B16.5, 150 lb. 14” to 24” elbows are 2-piece mitered and overwound. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

Fig #3345 Degree Elbow, ANSI 150 lb. Flange x Bell-End

1 1.75 1.75 1.06 1.51-1/2 2.25 2.25 1.37 2.32 2.50 2.50 1.81 4.02-1/2 3.00 3.00 1.81 6.03 3.00 3.00 1.81 7.04 4.00 4.00 1.81 10.06 5.00 5.00 2.25 15.08 5.50 5.50 2.50 23.010 6.50 6.50 2.75 34.012 7.50 7.50 3.00 54.0

Fittings meet the centerline-to-flange-face dimension of ANSI B16.5, 150 lb. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

“C”(in.)

Weight(lb.)

33

A

BC

34

A

B

Page 34: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988528

Fig #40Tee, Bell-End

1/2 1.00 1.00 0.6 3/4 1.25 1.06 0.7 1 1.62 1.06 1.0 1-1/2 2.37 1.25 1.5 2 2.62 1.81 2.0 2-1/2 3.12 1.81 2.8 3 3.62 1.81 3.5 4 4.12 1.81 6.0 6 5.62 2.25 10.0 8 9.00 2.50 17.0 10 11.00 2.75 27.0 12 12.00 3.00 44.0 14 14.00 3.00 54.0 16 15.00 3.50 65.0

Tees 1/2” through 12” rated for 150 psi. Tees 14” and larger rated for 100 psi. Higher pressure ratings are available. Bell-ends are designed to fit pipe with O.D.’s as shown in Fig.# 1. Please state pipe O.D. or manufacturer when ordering bell-end fittings for pipe with different O.D.’s. No returns allowed on sizes 14” and larger.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

Fig #41Tee, Plain-End

1/2 2.38 0.4 3/4 2.38 0.6 1 3.38 1.0 1-1/2 3.87 1.5 2 4.37 2.0 2-1/2 4.37 2.8 3 5.37 3.5 4 6.37 6.0 6 7.87 10.0 8 8.87 17.0 10 10.87 27.0 12 11.87 44.0 14 13.75 47.0 16 14.75 50.0 18 16.25 59.0 20 17.75 70.0 24 21.75 85.0

Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. Tees 1/2” to 12” are rated for 150 psi. Tees 14” and larger are rated for 100 psi. Higher pressure ratings are available. No returns allowed.

Size(in.)

“A”(in.)

Weight(lb.)

TEES

40

a b

c

AB

41

a b

c

A

Page 35: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988529

Fig #42Tee, ANSI, 150 lb. Flanged

1/2 2.50 1.8 3/4 2.50 2.5 1 3.50 4.0 1-1/2 4.00 6.0 2 4.50 8.0 2-1/2 5.00 9.2 3 5.50 12.5 4 6.50 20.0 6 8.00 28.0 8 9.00 49.0 10 11.00 69.0 12 12.00 110.0 14 14.00 130.0 16 15.00 170.0 18 16.50 195.0 20 18.00 280.0 24 22.00 385.0

Fittings meet the centerline-to-flange-face dimension of ANSI B16.5, 150 psi. Tees 1/2” through 12” are rated for 150 psi. Tees 14” and larger are rated for 100 psi. Higher pressure ratings are available. Please refer to Appendix B for flange assembly instructions. No returns allowed on sizes 14” and larger.

Size(in.)

“A”(in.)

Weight(lb.)

Fig #43Tee, ANSI, Combination Coupled

Bell x Bell x Flange

1/2 2.50 1.25 1.00 1.13/4 2.50 1.25 1.06 1.41 3.50 1.62 1.06 2.01-1/2 4.00 2.37 1.25 3.02 4.50 2.62 1.81 4.02-1/2 5.00 3.12 1.81 5.53 5.50 3.62 1.81 6.54 6.50 4.12 1.81 10.06 8.00 5.62 2.25 16.08 9.00 9.00 2.50 28.010 11.00 11.00 2.75 41.012 12.00 12.00 3.00 65.014 14.00 14.00 3.00 71.016 15.00 15.00 3.50 90.0 Plain-End x Plain-End x Flange 14 14.00 13.75 - 71.016 15.00 14.75 - 90.018 16.50 16.25 - 105.020 18.00 17.75 - 140.024 22.00 21.75 - 185.0 Fittings meet the centerline-to-flange-face dimension of ANSI B16.5, 150 psi. Tees 1/2” through 12” are rated for 150 psi. Tees 14” and larger are rated for 100 psi. Higher pressure ratings are available. Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. Please refer to Appendix B for flange assembly instructions. No returnsallowed.

Size(in.)

“A”(in.)

“B”(in.)

“C”(in.)

Weight(lb.)

42

A

a b

c

43

a b

c

BC

A

a b

c

B

A

Bell x Bell x Flange

Plain-End x Plain-End x Flange

43

a b

c

BC

A

a b

c

B

A

Bell x Bell x Flange

Plain-End x Plain-End x Flange

Page 36: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988530

Fig #44Tee, ANSI, Combination Coupled

Flange x Bell x Bell

1/2 2.50 1.25 1.06 1.13/4 2.50 1.25 1.06 1.11 3.50 1.62 1.06 1.51-1/2 4.00 2.37 1.25 2.12 4.50 2.62 1.81 3.52-1/2 5.00 3.12 1.81 5.13 5.50 3.62 1.81 6.54 6.50 4.12 1.81 10.56 8.00 5.62 2.25 16.08 9.00 9.00 2.50 29.010 11.00 11.00 2.75 32.012 12.00 12.00 3.00 65.014 14.00 14.00 3.00 71.016 15.00 15.00 3.50 90.0 Flange x Plain-End x Plain-End 14 14.00 13.75 - 71.016 15.00 14.75 - 90.018 16.50 16.25 - 105.020 18.00 17.75 - 140.024 22.00 21.75 - 185.0

Fittings meet the centerline-to-flange-face dimension of ANSI B16.5, 150 psi. Tees 1/2” through 12” are rated for 150 psi. Tees 14” and larger are rated for 100 psi. Higher pressure ratings are available. Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

“C”(in.)

Weight(lb.)

44

a b

c

a b

c

A B

Flange x Bell x Bell

Flange x Plain-End x Plain-End

A B C

44

a b

c

a b

c

A B

Flange x Bell x Bell

Flange x Plain-End x Plain-End

A B C

Page 37: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988531

Fig #45Tee, ANSI, Combination Coupled

Flange x Bell x Flange

1/2 2.50 1.25 1.00 1.63/4 2.50 1.25 1.06 2.01 3.50 1.62 1.06 3.01-1/2 4.00 2.37 1.25 4.52 4.50 2.62 1.81 6.02-1/2 5.00 3.12 1.81 8.33 5.50 3.62 1.81 9.54 6.50 4.12 1.81 14.06 8.00 5.62 2.25 22.08 9.00 9.00 2.50 38.010 11.00 11.00 2.75 55.012 12.00 12.00 3.00 76.014 14.00 14.00 3.00 100.016 15.00 15.00 3.50 130.0 Flange x Plain-End x Flange 14 14.00 13.75 - 100.016 15.00 14.75 - 130.018 16.50 16.25 - 150.020 18.00 17.75 - 210.024 22.00 21.75 - 285.0 Fittings meet the centerline-to-flange-face dimension of ANSI B16.5, 150 psi. Tees 1/2” through 12” are rated for 150 psi. Tees 14” and larger are rated for 100 psi. Higher pressure ratings are available. Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

“C”(in.)

Weight(lb.)

45

A B

a b

c

A

Flange x Plain-End x Flange

A B C

a b

c

Flange x Bell x Flange

A

45

A B

a b

c

A

Flange x Plain-End x Flange

A B C

a b

c

Flange x Bell x Flange

A

Page 38: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988532

Fig #46Tee, ANSI, Combination Coupled

Flange x Flange x Bell

1/2 2.50 1.25 1.00 1.63/4 2.50 1.25 1.06 2.01 3.50 1.62 1.06 3.01-1/2 4.00 2.37 1.25 4.52 4.50 2.62 1.81 6.02-1/2 5.00 3.12 1.81 8.33 5.50 3.62 1.81 9.54 6.50 4.12 1.81 14.06 8.00 5.62 2.25 22.08 9.00 9.00 2.50 38.010 11.00 11.00 2.75 55.012 12.00 12.00 3.00 76.014 14.00 14.00 3.00 100.016 15.00 15.00 3.50 130.0 Flange x Flange x Plain-End 14 14.00 13.75 - 100.016 15.00 14.75 - 130.018 16.50 16.25 - 150.020 18.00 17.75 - 210.024 22.00 21.75 - 285.0

Fittings meet the centerline-to-flange-face dimension of ANSI B16.5, 150 psi. Tees 1/2” through 12” are rated for 150 psi. Tees 14” and larger are rated for 100 psi. Higher pressure ratings are available. Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

“C”(in.)

Weight(lb.)

46

A

a b

c

A

B

Flange x Flange x Plain-End

A

a b

c

Flange x Flange x Bell

A

B

C

46

A

a b

c

A

B

Flange x Flange x Plain-End

A

a b

c

Flange x Flange x Bell

A

B

C

Page 39: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988533

Fig #47Tee, Reducing

Bell x Bell x Bell

1-1/2 x 1 2.37 1.25 1.06 1.42x1 2.62 1.81 1.06 1.92 x1-1/2 2.62 1.81 1.25 2.02-1/2 x1-1/2 3.12 1.81 1.25 2.62-1/2 x2 3.12 1.81 1.81 2.73x2 3.62 1.81 1.81 3.33x2-1/2 3.62 1.81 1.81 3.44x2 4.12 1.81 1.81 5.74x2-1/2 4.12 1.81 1.81 5.94x3 4.12 1.81 1.81 6.06x3 5.62 2.25 1.81 9.76x4 5.62 2.25 1.81 9.98x4 9.00 2.50 1.81 16.68x6 9.00 2.50 2.25 16.810x6 11.00 2.75 2.25 26.610x8 11.00 2.75 2.50 26.812x8 12.00 3.00 2.50 43.012x10 12.00 3.00 2.75 43.5 Plain-End x Plain-End x Bell 14x10 14.00 13.75 2.75 40.014x12 14.00 13.75 3.00 41.016x12 15.00 14.75 3.00 48.0 Plain-End x Plain-End x Plain-End 16x14 14.75 14.75 - 50.018x14 16.25 16.25 - 57.018x16 16.25 16.25 - 59.020x16 17.75 17.75 - 68.020x18 17.75 17.75 - 70.024x18 21.75 21.75 - 83.024x20 21.75 21.75 - 85.0

Tees 1-1/2” through 12” are rated for 150 psi. Tees 14” and larger are rated for 100 psi. Higher pressure ratings are available. Size reductions other than shown are available. Tees 14” and larger are available with bell-ends for socket adhesive joining. Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

“C”(in.)

Weight(lb.)

47

a b

c

a b

c

a b

c

Bell x Bell x Bell

Plain-End x Plain-End x Bell

Plain-End x Plain-End x Plain-End

AB

A

C

B

A

C

B

A

REDUCING TEES

Page 40: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988534

Fig #48Tee, Reducing, ANSI Flanged

1-1/2x1 4.0 4.0 5.52x1 4.5 4.5 7.02x1-1/2 4.5 4.5 7.52-1/2 x1-1/2 5.0 5.0 8.02-1/2x2 5.0 5.0 8.53x2 5.5 5.5 11.53x2-1/2 5.5 5.5 12.24x2 6.5 6.5 18.04x2-1/2 6.5 6.5 18.84x3 6.5 6.5 19.06x3 8.0 8.0 25.06x4 8.0 8.0 26.08x4 9.0 9.0 43.08x6 9.0 9.0 47.010x6 11.0 11.0 61.010x8 11.0 11.0 66.512x8 12.0 12.0 100.012x10 12.0 12.0 105.014x10 14.0 14.0 115.014x12 14.0 14.0 123.016x12 15.0 15.0 151.016x14 15.0 15.0 159.018x14 16.5 16.5 179.018x16 16.5 16.5 190.020x16 18.0 18.0 250.020x18 18.0 18.0 255.024x18 22.0 22.0 330.024x20 22.0 22.0 355.0

Tees 1-1/2” through 12” are rated for 150 psi. Tees 14” and larger are rated for 100 psi. Higher pressure ratings are available. Size reductions other than shown are available. Fittings meet the centerline-to-flange-face dimension of ANSI B16.5, 150 psi. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

48

a b

c

A

B

Page 41: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988535

Fig #49Tee, Reducing, Combination Coupled

Bell x Bell x Flange

1-1/2x1 4.0 2.37 1.06 1.52x1 4.5 2.62 1.81 2.02x1-1/2 4.5 2.62 1.81 2.12-1/2x1-1/2 5.0 3.12 1.81 3.82-1/2x2 5.0 3.12 1.81 3.93x2 5.5 3.62 1.81 4.53x2-1/2 5.5 3.62 1.81 4.64x2 6.5 4.12 1.81 6.34x2-1/2 6.5 4.12 1.81 6.54x3 6.5 4.12 1.81 6.96x3 8.0 5.62 2.25 15.06x4 8.0 5.62 2.25 15.38x4 9.0 9.00 2.50 21.08x6 9.0 9.00 2.50 23.010x6 11.0 11.00 2.75 32.010x8 11.0 11.00 2.75 37.012x8 12.0 12.00 3.00 54.012x10 12.0 12.00 3.00 59.0 Plain-End x Plain-End x Flange 14x10 14.0 13.75 - 57.014x12 14.0 13.75 - 63.016x12 15.0 14.75 - 69.016x14 15.0 14.75 - 75.018x14 16.5 16.25 - 87.018x16 16.5 16.25 - 94.020x16 18.0 17.75 - 105.020x18 18.0 17.75 - 115.024x18 22.0 21.75 - 130.024x20 22.0 21.75 - 150.0 Tees 1-1/2” through 12” are rated for 150 psi. Tees 14” and larger are rated for 100 psi. Higher pressure ratings are available. Size reductions other than shown are available. Tees 14” and larger are available with bell-ends for socket adhesive joining. Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

“C”(in.)

Weight(lb.)

49

a b

c

a b

c

Bell x Bell x Flange

Plain-End x Plain-End x Flange

BC

A

B

A

Page 42: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988536

Fig #50Tapered Body Reducer, Concentric

Bell x Bell

1-1/2x1 1.25 1.37 1.06 0.42x1 2.75 1.81 1.06 0.62x1-1/2 1.75 1.81 1.37 1.02-1/2x1-1/2 2.38 1.81 1.25 1.22-1/2x2 2.50 1.81 1.81 1.23x1-1/2 3.75 1.81 1.25 1.43x2 2.50 1.81 1.81 1.43x2-1/2 1.25 1.81 1.81 1.64x2 2.50 1.81 1.81 2.04x2-1/2 3.75 1.81 1.81 2.04x3 2.50 1.81 1.81 2.06x3 5.13 2.25 1.81 3.46x4 4.75 2.25 1.81 3.46x5 3.38 2.25 1.81 4.08x4 6.25 2.50 1.81 6.08x5 8.75 2.50 1.81 6.08x6 5.62 2.50 2.25 6.010x6 6.00 2.75 2.25 9.010x8 6.00 2.75 2.50 9.012x8 7.63 3.00 2.50 12.012x10 7.50 3.00 2.75 12.0 Plain-End x Bell-End 14x10 12.75 2.75 - 18.014x12 12.25 3.00 - 18.016x12 14.25 3.00 - 18.0

Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. No returns allowed on sizes 14” and larger.

Size(in.)

“A”(in.)

“B”(in.)

“C”(in.)

Weight(lb.)

Bell x Bell

Plain-End x Bell

50

A CB

BA

TAPERED BODY REDUCERS

Page 43: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988537

Fig #50-PETapered Body Reducer, Concentric, Plain-End

1-1/2x1 4.25 0.42x1 4.75 0.62x1-1/2 4.75 1.02-1/2x1 5.25 1.22-1/2x1-1/2 5.25 1.22-1/2x2 5.25 1.23x1-1/2 5.75 1.43x2 5.75 1.43x2-1/2 5.75 1.64x2 6.75 2.04x2-1/2 6.75 2.04x3 6.75 2.56x3 8.75 3.46x4 8.75 3.46x5 8.75 3.48x4 10.75 6.08x5 10.75 6.08x6 10.75 6.510x6 11.75 9.010x8 11.75 9.012x8 13.75 12.012x10 13.75 12.014x10 15.62 18.014x12 15.62 18.016x12 17.50 18.016x14 17.50 22.018x14 18.50 26.018x16 18.50 26.020x16 19.50 30.020x18 19.50 30.024x18 23.50 38.024x20 23.50 38.0

Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. No returns allowed.

Size(in.)

“A”(in.)

Weight(lb.)

50-PE

A

Page 44: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988538

Fig #51Tapered Body Reducer, Eccentric

Bell x Bell

1-1/2x1 1.25 1.37 1.00 0.42x1 2.50 1.81 1.00 0.62x1-1/2 1.25 1.81 1.37 1.02-1/2x1-1/2 2.38 1.81 1.37 1.22-1/2x2 2.00 1.81 1.81 1.23x1-1/2 3.75 1.81 1.37 1.43x2 2.50 1.81 1.81 1.43x2-1/2 1.25 1.81 1.81 1.64x2 5.00 1.81 1.81 2.04x2-1/2 3.75 1.81 1.81 2.04x3 2.75 1.81 1.81 2.06x3 4.75 2.25 1.81 3.46x4 4.50 2.25 1.81 3.48x4 5.75 2.50 1.81 6.08x6 6.25 2.50 2.25 6.010x6 6.50 2.75 2.25 9.010x8 6.00 2.75 2.50 9.012x8 7.50 3.00 2.50 12.012x10 7.62 3.00 2.75 12.0 Plain-End x Bell 14x10 12.75 2.75 18.014x12 12.75 3.00 18.016x12 14.25 3.00 22.0 Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. No returns allowed on sizes 14” and larger.

Size(in.)

“A”(in.)

“B”(in.)

“C”(in.)

Weight(lb.)

Bell x Bell

Plain-End x Bell

51

A CB

A B

Page 45: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988539

Fig #51-PETapered Body Reducer, Eccentric, Plain End

1-1/2x1 4.25 0.42x1 4.75 0.62x1-1/2 4.75 1.02-1/2x1 5.25 1.22-1/2x1-1/2 5.25 1.22-1/2x2 5.25 1.23x1-1/2 5.75 1.43x2 5.75 1.43x2-1/2 5.75 1.64x2 6.75 2.04x2-1/2 6.75 2.04x3 6.75 2.06x3 8.75 3.46x4 8.75 3.46x5 8.75 3.48x4 10.75 6.08x5 10.75 6.08x6 10.75 6.510x6 11.75 9.010x8 11.75 9.012x8 13.75 12.012x10 13.75 12.014x10 15.62 18.014x12 15.62 18.016x12 17.50 18.016x14 17.50 22.018x14 18.50 26.018x16 18.50 26.020x16 19.50 30.020x18 19.50 30.024x18 23.50 38.024x20 23.50 38.0

Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. No returns allowed.

Size(in.)

“A”(in.)

Weight(lb.)

51-PE

A

Page 46: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988540

Fig #53Tapered Body Reducer, ANSI Flanged, Concentric

1-1/2x1 4.5 1.52x1 5.0 1.82x1-1/2 5.0 2.52-1/2x1 5.5 2.02-1/2x1-1/2 5.5 2.92-1/2x2 5.5 3.53x1-1/2 6.0 4.03x2 6.0 6.03x2-1/2 6.0 7.04x2 7.0 8.44x2-1/2 7.0 8.84x3 7.0 10.06x3 9.0 13.06x4 9.0 15.06x5 9.0 16.08x4 11.0 22.08x5 11.0 24.08x6 11.0 26.010x6 12.0 30.010x8 12.0 37.012x8 14.0 48.012x10 14.0 54.014x10 16.0 63.014x12 16.0 70.016x12 18.0 82.016x14 18.0 90.018x14 19.0 102.018x16 19.0 110.020x16 20.0 138.020x18 20.0 162.024x18 24.0 204.024x20 24.0 228.0

Fittings meet the flange-face to flange-face dimension of ANSI B16.5, 150 psi. Please refer to Appendix B for flange assembly instructions. No returns allowed on sizes 14” and larger.

Size(in.)

“A”(in.)

Weight(lb.)

53

A

Page 47: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988541

Fig #54Tapered Body Reducer, ANSI Flanged, Eccentric

1-1/2x1 4.5 1.52x1 5.0 1.82x1-1/2 5.0 2.52-1/2x1 5.5 2.02-1/2x1-1/2 5.5 2.92-1/2x2 5.5 3.53x1-1/2 6.0 4.03x2 6.0 6.03x2-1/2 6.0 7.04x2 7.0 8.44x2-1/2 7.0 8.84x3 7.0 10.06x3 9.0 13.06x4 9.0 15.06x5 9.0 16.08x4 11.0 22.08x5 11.0 24.08x6 11.0 26.010x6 12.0 30.010x8 12.0 37.012x8 14.0 48.012x10 14.0 54.014x10 16.0 63.014x12 16.0 70.016x12 18.0 82.016x14 18.0 90.018x14 19.0 102.018x16 19.0 110.020x16 20.0 138.020x18 20.0 162.024x18 24.0 204.024x20 24.0 228.0

Fittings meet the flange-face to flange-face dimension of ANSI B16.5, 150 psi. Please refer to Appendix B for flange assembly instructions. No returns allowed on sizes 14” and larger.

Size(in.)

“A”(in.)

Weight(lb.)

54

A

Page 48: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988542

Fig #55Tapered Body Reducer, Combination Coupled, Concentric

Bell x Flange

1-1/2x1 4.5 1.38 1.02x1 5.0 1.81 1.22x1-1/2 5.0 1.81 1.62-1/2x1-1/2 5.5 1.81 1.82-1/2x2 5.5 1.81 2.73x1-1/2 6.0 1.81 2.53x2 6.0 1.81 2.53x2-1/2 6.0 1.81 2.54x2 7.0 1.81 3.54x2-1/2 7.0 1.81 4.24x3 7.0 1.81 5.06x3 9.0 2.25 7.06x4 9.0 2.25 7.96x5 9.0 2.25 8.18x4 11.0 2.50 10.58x5 11.0 2.50 10.88x6 11.0 2.50 12.010x6 12.0 2.75 15.010x8 12.0 2.75 21.012x8 14.0 3.00 24.012x10 14.0 3.00 27.0 Plain-End x Flange 1-1/2x1 4.38 - 1.02x1 4.88 - 1.22x1-1/2 4.88 - 1.62-1/2x1-1/2 5.38 - 1.82-1/2x2 5.38 - 2.73x1-1/2 5.88 - 2.53x2 5.88 - 2.53x2-1/2 5.88 - 2.54x2 6.88 - 3.54x2-1/2 6.88 - 4.24x3 6.88 - 5.06x3 8.88 - 7.06x4 8.88 - 7.96x5 8.88 - 8.18x4 10.88 - 10.58x5 10.88 - 10.88x6 10.88 - 12.010x6 11.88 - 15.010x8 11.88 - 21.012x8 13.88 - 24.012x10 13.88 - 27.014x10 15.75 - 28.014x12 15.75 - 31.016x12 17.75 - 52.016x14 17.75 - 60.018x14 18.75 - 65.018x16 18.75 - 73.020x16 19.75 - 80.020x18 19.75 - 88.024x18 23.75 - 145.024x20 23.75 - 155.0

Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

55

Bell x Flange

Plain-End x Flange

AB

A

55

Bell x Flange

Plain-End x Flange

AB

A

Page 49: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988543

Fig #56Tapered Body Reducer, Combination Coupled, Eccentric

Bell x Flange

1-1/2x1 4.5 1.38 1.02x1 5.0 1.81 1.22x1-1/2 5.0 1.81 1.62-1/2x1-1/2 5.5 1.81 1.82-1/2x2 5.5 1.81 2.73x1-1/2 6.0 1.81 2.53x2 6.0 1.81 2.53x2-1/2 6.0 1.81 2.54x2 7.0 1.81 3.54x2-1/2 7.0 1.81 4.24x3 7.0 1.81 5.06x3 9.0 2.25 7.06x4 9.0 2.25 7.96x5 9.0 2.25 8.18x4 11.0 2.50 10.58x5 11.0 2.50 10.88x6 11.0 2.50 12.010x6 12.0 2.75 15.010x8 12.0 2.75 21.012x8 14.0 3.00 27.012x10 14.0 3.00 27.0 Plain-End x Flange 1-1/2x1 4.38 - 1.02x1 4.88 - 1.22x1-1/2 4.88 - 1.62-1/2x1-1/2 5.38 - 1.82-1/2x2 5.38 - 2.73x1-1/2 5.88 - 2.53x2 5.88 - 2.53x2-1/2 5.88 - 2.54x2 6.88 - 3.54x2-1/2 6.88 - 4.24x3 6.88 - 5.06x3 8.88 - 7.06x4 8.88 - 7.96x5 8.88 - 8.18x4 10.88 - 10.58x5 10.88 - 10.88x6 10.88 - 12.010x6 11.88 - 15.010x8 11.88 - 21.012x8 13.88 - 24.012x10 13.88 - 27.014x10 15.75 - 28.014x12 15.75 - 31.016x12 17.75 - 52.016x14 17.75 - 60.018x14 18.75 - 65.018x16 18.75 - 73.020x16 19.75 - 80.020x18 19.75 - 88.024x18 23.75 - 145.024x20 23.75 - 155.0

Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

56

Bell x Flange

Plain-End x Flange

AB

A

56

Bell x Flange

Plain-End x Flange

AB

A

Page 50: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988544

Fig #57Tapered Body Reducer, Combination Coupled, Concentric

Flange x Bell

1-1/2x1 4.5 1.06 1.02x1 5.0 1.06 2.12x1-1/2 5.0 1.37 2.52-1/2x1-1/2 5.5 1.37 3.72-1/2x2 5.5 1.81 3.73x1-1/2 6.0 1.37 4.43x2 6.0 1.81 4.23x2-1/2 6.0 1.81 4.64x2 7.0 1.81 6.54x2-1/2 7.0 1.81 6.54x3 7.0 1.81 6.56x3 9.0 1.81 12.36x4 9.0 1.81 12.46x5 9.0 1.81 12.48x4 11.0 1.81 18.08x5 11.0 1.81 18.08x6 11.0 2.25 18.010x6 12.0 2.25 24.010x8 12.0 2.50 24.012x8 14.0 2.50 33.012x10 14.0 2.75 33.014x10 16.0 2.75 48.014x12 16.0 3.00 48.016x12 18.0 3.00 62.0 Flange x Plain-End 1-1/2x1 4.38 - 1.02x1 4.38 - 2.12x1-1/2 4.88 - 2.52-1/2x1-1/2 5.38 - 3.72-1/2x2 5.38 - 3.73x1-1/2 5.88 - 4.43x2 5.88 - 4.23x2-1/2 5.88 - 4.64x2 6.88 - 6.54x2-1/2 6.88 - 6.54x3 6.88 - 6.56x3 8.88 - 12.36x4 8.88 - 12.46x5 8.88 - 12.98x4 10.88 - 18.08x5 10.88 - 18.08x6 10.88 - 18.010x6 11.88 - 24.010x8 11.88 - 24.012x8 13.88 - 33.012x10 13.88 - 33.014x10 15.88 - 48.014x12 15.88 - 48.016x12 17.75 - 62.016x14 17.75 - 62.018x14 18.75 - 72.018x16 18.75 - 72.020x16 19.75 - 100.020x18 19.75 - 100.024x18 23.75 - 150.024x20 23.75 - 160.0

Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

57

Flange x Bell

Flange x Plain-End

A B

A

57

Flange x Bell

Flange x Plain-End

A B

A

Page 51: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988545

Fig #58Tapered Body Reducer, Combination Coupled, Eccentric

Flange x Bell

1-1/2x1 4.5 1.06 1.02x1 5.0 1.06 2.12x1-1/2 5.0 1.37 2.52-1/2x1-1/2 5.5 1.37 3.72-1/2x2 5.5 1.81 3.73x1-1/2 6.0 1.37 4.43x2 6.0 1.81 4.23x2-1/2 6.0 1.81 4.64x2 7.0 1.81 6.54x2-1/2 7.0 1.81 6.54x3 7.0 1.81 6.56x3 9.0 1.81 12.36x4 9.0 1.81 12.46x5 9.0 1.81 12.48x4 11.0 1.81 18.08x5 11.0 1.81 18.08x6 11.0 2.25 18.010x6 12.0 2.25 24.010x8 12.0 2.50 24.012x8 14.0 2.50 33.012x10 14.0 2.75 33.014x10 16.0 2.75 48.014x12 16.0 3.00 48.016x12 18.0 3.00 62.0 Flange x Plain-End 1-1/2x1 4.38 - 1.02x1 4.38 - 2.12x1-1/2 4.88 - 2.52-1/2x1-1/2 5.38 - 3.72-1/2x2 5.38 - 3.73x1-1/2 5.88 - 4.43x2 5.88 - 4.23x2-1/2 5.88 - 4.64x2 6.88 - 6.54x2-1/2 6.88 - 6.54x3 6.88 - 6.56x3 8.88 - 12.36x4 8.88 - 12.46x5 8.88 - 12.98x4 10.88 - 18.08x5 10.88 - 18.08x6 10.88 - 18.010x6 11.88 - 24.010x8 11.88 - 24.012x8 13.88 - 33.012x10 13.88 - 33.014x10 15.88 - 48.014x12 15.88 - 48.016x12 17.75 - 62.016x14 17.75 - 62.018x14 18.75 - 72.018x16 18.75 - 72.020x16 19.75 - 100.020x18 19.75 - 100.024x18 23.75 - 140.024x20 23.75 - 140.0

Plain-ends are designed for butt and wrap joining. Butt and wrap kits are available, please see Fig.# 90. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

58

Flange x Bell

Flange x Plain-End

BA

A

58

Flange x Bell

Flange x Plain-End

BA

A

Page 52: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988546

Fig #60Saddle with Fiberglass NPT Thread, Reducing

1-1/2x1/2 4.00 180 2.07 1.02x1/2 4.00 180 2.30 1.02-1/2x1/2 4.00 180 2.55 1.33x1/2 4.00 180 2.87 1.34x1/2 4.00 180 3.37 1.66x1/2 4.00 120 4.43 1.58x1/2 4.00 90 5.43 1.510x1/2 4.00 45 6.50 1.012x1/2 4.00 45 7.49 1.21-1/2x3/4 4.00 180 2.07 1.02x3/4 4.00 180 2.30 1.02-1/2x3/4 4.00 180 2.55 1.33x3/4 4.00 180 2.87 1.34x3/4 4.00 180 3.37 1.66x3/4 4.00 120 4.43 1.58x3/4 4.00 90 5.43 1.510x3/4 4.00 90 6.50 1.812x3/4 4.00 45 7.49 1.21-1/2x1 6.00 180 2.20 1.42x1 6.00 180 2.43 1.42-1/2x1 6.00 180 2.68 1.73x1 6.00 180 3.00 1.74x1 6.00 180 3.50 2.16x1 6.00 120 4.56 2.18x1 6.00 120 5.56 2.610x1 6.00 90 6.62 2.412x1 6.00 90 7.62 2.92-1/2x1-1/4 6.00 180 2.68 1.93x1-1/4 6.00 180 3.00 1.94x1-1/4 6.00 180 3.50 2.36x1-1/4 6.00 120 4.56 2.38x1-1/4 6.00 120 5.56 2.810x1-1/4 6.00 90 6.62 2.612x1-1/4 6.00 90 7.62 3.12-1/2x1-1/2 6.00 180 2.81 2.13x1-1/2 6.00 180 3.13 2.14x1-1/2 6.00 180 3.63 2.56x1-1/2 6.00 120 4.69 2.58x1-1/2 6.00 120 5.69 3.010x1-1/2 6.00 90 6.75 2.812x1-1/2 6.00 90 7.75 3.33x2 8.00 180 3.25 2.84x2 8.00 180 3.75 3.36x2 8.00 120 4.81 3.28x2 8.00 120 5.81 3.910x2 8.00 90 6.87 3.712x2 8.00 90 7.87 4.34x2-1/2 8.00 180 4.43 3.56x2-1/2 8.00 180 5.49 4.58x2-1/2 8.00 180 6.49 5.610x2-1/2 8.00 120 7.55 4.812x2-1/2 8.00 120 8.55 5.54x3 10.00 180 4.43 4.16x3 10.00 180 5.49 5.48x3 10.00 180 6.49 6.710x3 10.00 120 7.55 5.712x3 10.00 120 8.55 6.66x4 12.00 180 5.49 6.68x4 12.00 180 6.49 8.210x4 12.00 180 7.55 9.812x4 12.00 120 8.55 8.18x6 17.00 180 6.37 11.910x6 17.00 180 7.43 14.112x6 17.00 180 8.43 16.310x8 18.00 180 7.58 16.012x8 18.00 180 8.58 18.414x8 18.00 180 9.71 20.2

No returns allowed.

Size(in.)

“L”(in.)

“Ø”(ang.)

“A”(in.)

Weight(lb.)

NPT OUTLETSIZE

A

L

Ø

60

NPT OUTLETSIZE

A

L

Ø

60

SADDLES

Page 53: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988547

Fig #60-45Saddle with Fiberglass NPT Thread, Reducing, 45 Degree

1-1/2x1/2 5.00 180 2.90 1.02x1/2 5.00 180 3.24 1.22-1/2x1/2 5.00 180 3.59 1.53x1/2 6.00 180 4.03 1.74x1/2 6.00 180 4.74 2.16x1/2 6.00 120 6.24 2.18x1/2 6.00 90 7.66 1.710x1/2 6.00 90 9.16 2.412x1/2 6.00 90 10.58 2.91-1/2x3/4 5.00 180 3.15 1.02x3/4 5.00 180 3.49 1.22-1/2x3/4 5.00 180 3.84 1.53x3/4 6.00 180 4.28 1.74x3/4 6.00 180 4.99 2.16x3/4 6.00 120 6.49 2.18x3/4 6.00 90 7.91 1.710x3/4 6.00 90 9.41 2.412x3/4 6.00 90 10.83 2.91-1/2x1 6.00 180 3.40 1.02x1 6.00 180 3.74 1.22-1/2x1 6.00 180 4.09 1.53x1 6.00 180 4.53 1.74x1 6.00 180 5.24 2.16x1 6.00 120 6.74 2.18x1 6.00 120 8.16 2.610x1 6.00 90 9.66 2.412x1 6.00 90 11.08 2.92-1/2x1-1/4 7.00 180 4.28 1.93x1-1/4 7.00 180 4.72 2.14x1-1/4 7.00 180 5.43 2.76x1-1/4 8.00 120 6.93 2.98x1-1/4 8.00 120 8.53 3.810x1-1/4 8.00 90 9.85 3.412x1-1/4 8.00 90 11.27 3.82-1/2x1-1/2 7.00 180 4.65 2.13x1-1/2 7.00 180 5.09 2.34x1-1/2 8.00 180 5.80 3.26x1-1/2 8.00 120 7.30 3.18x1-1/2 9.00 120 8.72 4.410x1-1/2 9.00 90 10.22 4.012x1-1/2 9.00 90 11.64 4.43x2 8.00 180 5.34 2.84x2 8.00 180 6.05 3.46x2 9.00 180 7.55 4.98x2 9.00 120 8.97 4.610x2 10.00 90 10.47 4.512x2 10.00 90 11.89 5.04x2-1/2 9.00 180 6.49 3.96x2-1/2 9.00 180 7.99 5.18x2-1/2 9.00 120 9.41 4.810x2-1/2 10.00 120 10.91 5.912x2-1/2 10.00 90 12.33 5.24x3 11.00 180 6.93 4.56x3 11.00 180 8.43 5.98x3 11.00 180 9.85 5.610x3 11.00 120 11.35 6.412x3 11.00 120 12.77 5.66x4 13.00 180 8.93 7.28x4 13.00 180 10.35 9.410x4 13.00 120 11.85 7.712x4 13.00 120 13.27 8.58x6 19.00 180 12.10 14.010x6 19.00 180 13.60 15.912x6 19.00 120 15.02 12.710x8 22.00 180 14.97 19.212x8 22.00 180 16.39 21.414x8 22.00 180 17.98 24.0 No returns allowed.

Size(in.)

“L”(in.)

“Ø”(ang.)

“A”(in.)

Weight(lb.)

NPT OUTLETSIZE

Ø

60-45

L

A

45°

NPT OUTLETSIZE

Ø

60-45

L

A

45°

Page 54: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988548

Fig #60-SSSaddle with 316 Stainless Steel Bushing, Threaded Reducing

1-1/2x1/2 4.00 180 1.88 1.12x1/2 4.00 180 2.18 1.12-1/2x1/2 4.00 180 2.37 1.43x1/2 4.00 180 2.68 1.44x1/2 4.00 180 3.18 1.56x1/2 4.00 120 4.25 1.68x1/2 4.00 90 5.25 1.110x1/2 4.00 90 6.30 1.312x1/2 4.00 45 7.30 1.21-1/2x3/4 6.00 180 2.01 1.22x3/4 6.00 180 2.25 1.22-1/2x3/4 6.00 180 2.50 1.53x3/4 6.00 180 2.81 1.54x3/4 6.00 180 3.31 1.86x3/4 6.00 120 4.37 1.78x3/4 6.00 120 5.37 1.710x3/4 6.00 90 6.43 2.012x3/4 6.00 90 7.43 1.42x1 6.00 180 2.25 1.72-1/2x1 6.00 180 2.50 2.03x1 6.00 180 2.81 2.04x1 6.00 180 3.31 2.46x1 6.00 120 4.37 2.48x1 6.00 120 5.37 2.910x1 6.00 90 6.43 2.712x1 6.00 90 7.43 3.22-1/2x1-1/4 6.00 180 2.50 2.33x1-1/4 6.00 180 2.81 2.34x1-1/4 6.00 180 3.31 2.76x1-1/4 6.00 120 4.37 2.78x1-1/4 6.00 120 5.37 3.210x1-1/4 6.00 90 6.43 3.012x1-1/4 6.00 90 7.43 3.53x1-1/2 8.00 180 2.93 2.84x1-1/2 8.00 180 3.43 3.26x1-1/2 8.00 120 4.50 3.28x1-1/2 8.00 120 5.50 3.710x1-1/2 8.00 90 6.56 3.512x1-1/2 8.00 90 7.56 4.04x2 10.00 180 3.43 4.36x2 10.00 180 4.50 4.28x2 10.00 180 5.50 4.910x2 10.00 120 6.56 4.712x2 10.00 120 7.56 5.36x2-1/2 10.00 180 4.50 5.58x2-1/2 10.00 180 5.50 6.510x2-1/2 10.00 120 6.56 5.812x2-1/2 10.00 120 7.56 6.56x3 12.00 180 4.50 6.98x3 12.00 180 5.50 8.210x3 12.00 120 6.56 7.212x3 12.00 120 7.56 8.1 Due to thread fit-up “A” dimension may vary. No returns allowed.

Size(in.)

“L”(in.)

“Ø”(ang.)

“A”(in.)

Weight(lb.)

NPT OUTLETSIZE

L

Ø

60-SS

A

NPT OUTLETSIZE

L

Ø

60-SS

A

Page 55: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988549

Fig #60-SS-45Saddle with 316 Stainless Steel Bushing, Threaded Reducing 45 Degree

1-1/2x1/2 5.00 180 3.59 1.12x1/2 5.00 180 3.93 1.12-1/2x1/2 5.00 180 4.28 1.43x1/2 6.00 180 4.72 1.44x1/2 6.00 180 5.43 1.56x1/2 6.00 120 6.93 1.68x1/2 6.00 90 8.35 1.110x1/2 6.00 90 9.85 1.312x1/2 6.00 90 11.27 1.21-1/2x3/4 5.00 180 3.84 1.22x3/4 5.00 180 4.18 1.22-1/2x3/4 5.00 180 4.53 1.53x3/4 6.00 180 4.97 1.54x3/4 6.00 180 5.68 1.86x3/4 6.00 120 7.18 1.78x3/4 6.00 120 8.60 1.710x3/4 6.00 90 10.10 2.012x3/4 6.00 90 11.52 1.42-1/2x1 7.00 180 5.15 2.03x1 7.00 180 5.59 2.04x1 7.00 180 6.30 2.46x1 8.00 120 7.80 2.48x1 8.00 120 9.22 2.910x1 8.00 90 10.72 2.712x1 8.00 90 12.14 3.22-1/2x1-1/4 7.00 180 5.15 2.33x1-1/4 7.00 180 5.59 2.34x1-1/4 8.00 180 6.30 2.76x1-1/4 8.00 120 7.80 2.78x1-1/4 9.00 120 9.22 3.210x1-1/4 9.00 90 10.72 3.012x1-1/4 9.00 90 12.14 3.53x1-1/2 8.00 180 5.97 2.84x1-1/2 8.00 180 6.68 3.26x1-1/2 9.00 180 8.18 3.28x1-1/2 9.00 120 9.60 3.710x1-1/2 10.00 90 11.10 3.512x1-1/2 10.00 90 12.52 4.04x2 11.00 180 7.05 4.36x2 11.00 180 8.55 4.28x2 11.00 120 9.97 4.910x2 11.00 120 11.47 4.712x2 11.00 90 12.89 5.36x2-1/2 11.00 180 9.05 5.58x2-1/2 11.00 120 10.47 6.510x2-1/2 11.00 120 11.97 5.812x2-1/2 11.00 90 13.39 6.56x3 13.00 180 9.68 6.98x3 13.00 180 11.10 8.210x3 13.00 120 12.60 7.212x3 13.00 120 14.02 8.1

Due to thread fit-up “A” dimension may vary. No returns allowed.

Size(in.)

“L”(in.)

“Ø”(ang.)

“A”(in.)

Weight(lb.)

NPT OUTLETSIZE

Ø

60-SS-45

L

A

45°

NPT OUTLETSIZE

Ø

60-SS-45

L

A

45°

Page 56: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988550

Fig #61Saddle with Bell Outlet, Reducing

2x3/4 4.00 180 1.43 1.00 0.83x3/4 4.00 180 2.00 1.00 1.14x3/4 6.00 180 2.50 1.00 1.96x3/4 6.00 120 3.56 1.00 1.98x3/4 6.00 90 4.56 1.00 1.910x3/4 6.00 45 5.63 1.00 1.912x3/4 6.00 45 6.63 1.00 1.52x1 6.00 180 1.43 1.06 0.93x1 6.00 180 2.00 1.06 1.64x1 6.00 180 2.50 1.06 2.06x1 6.00 120 3.56 1.06 2.08x1 6.00 120 4.56 1.06 2.010x1 6.00 90 5.63 1.06 2.312x1 6.00 90 6.63 1.06 2.83x1-1/4 6.00 180 2.00 1.25 1.74x1-1/4 6.00 180 2.50 1.25 2.16x1-1/4 6.00 120 3.56 1.25 2.18x1-1/4 6.00 120 4.56 1.25 2.110x1-1/4 6.00 90 5.63 1.25 2.412x1-1/4 6.00 90 6.63 1.25 2.93x1-1/2 6.00 180 2.00 1.37 1.74x1-1/2 6.00 180 2.50 1.37 2.16x1-1/2 6.00 120 3.56 1.37 2.18x1-1/2 6.00 120 4.56 1.37 2.110x1-1/2 6.00 90 5.63 1.37 2.412x1-1/2 6.00 90 6.63 1.37 2.93x2 8.00 180 2.00 1.81 1.94x2 8.00 180 2.50 1.81 2.36x2 8.00 120 3.56 1.81 2.38x2 8.00 120 4.56 1.81 2.310x2 8.00 90 5.63 1.81 2.612x2 8.00 90 6.63 1.81 3.14x3 10.00 180 2.50 1.81 4.16x3 10.00 180 3.56 1.81 4.08x3 10.00 180 4.56 1.81 4.910x3 10.00 120 5.63 1.81 4.612x3 10.00 120 6.63 1.81 5.26x4 12.00 180 3.56 1.81 6.68x4 12.00 180 4.56 1.81 8.110x4 12.00 180 5.63 1.81 9.812x4 12.00 120 6.63 1.81 8.18x6 17.00 180 4.56 2.25 11.910x6 17.00 180 5.63 2.25 14.112x6 17.00 180 6.63 2.25 16.310x8 18.00 180 5.63 2.50 16.012x8 18.00 180 6.63 2.50 18.312x10 21.00 180 6.63 2.75 21.414x12 24.00 180 7.50 3.00 29.7 Bell-ends are designed to fit pipe with O.D.’s as shown in Fig.# 1. Please state O.D. or pipe manufacturer when ordering bell-end fittings for pipe with different O.D.’s. No returns allowed.

Size(in.)

Weight(lb.)

“L”(in.)

“Ø”(ang.)

“A”(in.)

“B”(in.)

L

Ø

61

A

B

NOM. OUTLETSIZE

L

Ø

61

A

B

NOM. OUTLETSIZE

Page 57: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988551

Fig #61-45Saddle with Bell Outlet, Reducing 45 Degree

2 x3/4 5.00 180 2.49 1.00 0.83x3/4 6.00 180 3.28 1.00 1.14x3/4 6.00 180 4.00 1.00 1.96x3/4 6.00 120 5.49 1.00 1.98x3/4 6.00 90 6.91 1.00 1.910x3/4 6.00 90 8.41 1.00 1.912x3/4 6.00 90 9.83 1.00 1.52x1 6.00 180 2.60 1.06 0.93x1 6.00 180 3.40 1.06 1.64x1 6.00 180 4.10 1.06 2.06x1 6.00 120 5.60 1.06 2.08x1 6.00 120 7.03 1.06 2.010x1 6.00 90 8.53 1.06 2.312x1 6.00 90 9.95 1.06 2.83x1-1/4 7.00 180 3.65 1.25 1.74x1-1/4 7.00 180 4.36 1.25 2.16x1-1/4 8.00 120 5.86 1.25 2.18x1-1/4 8.00 120 7.28 1.25 2.110x11/4 8.00 90 8.78 1.25 2.412x1-1/4 8.00 90 10.20 1.25 2.93x1-1/2 7.00 180 3.65 1.37 1.74x1-1/2 8.00 180 4.36 1.37 2.16x1-1/2 8.00 120 5.86 1.37 2.18x1-1/2 9.00 120 7.28 1.37 2.110x1-1/2 9.00 90 8.78 1.37 2.412x1-1/2 9.00 90 10.20 1.37 2.93x2 8.00 180 3.90 1.81 1.94x2 8.00 180 4.61 1.81 2.36x2 9.00 180 6.11 1.81 2.38x2 9.00 120 7.53 1.81 2.310x2 10.00 90 9.03 1.81 2.612x2 10.00 90 10.45 1.81 3.14x3 11.00 180 5.18 1.81 4.16x3 11.00 180 6.68 1.81 4.08x3 11.00 180 8.10 1.81 4.910x3 11.00 120 9.60 1.81 4.612x3 11.00 120 11.02 1.81 5.26x4 13.00 180 7.18 1.81 6.68x4 13.00 180 8.60 1.81 8.110x4 13.00 120 10.10 1.81 9.812x4 13.00 120 11.52 1.81 8.18x6 19.00 180 9.66 2.25 11.910x6 19.00 180 11.16 2.25 14.112x6 19.00 120 12.58 2.25 16.310x8 22.00 180 12.16 2.50 16.012x8 22.00 180 13.58 2.50 18.314x8 22.00 180 14.81 2.50 24.0 Bell-ends are designed to fit pipe with O.D.’s as shown in Fig.# 1. Please state O.D. or pipe manufacturer when ordering bell-end fittings for pipe with different O.D.’s. No returns allowed.

Size(in.)

Weight(lb.)

“L”(in.)

“Ø”(ang.)

“A”(in.)

“B”(in.)

Ø

61-45

L

45°

A

B NOM. OUTLETSIZE

Ø

61-45

L

45°

A

B NOM. OUTLETSIZE

Page 58: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988552

Fig #62Saddle with Plain-End Pipe Stub, Reducing

1-1/2x1 6.00 180 3.87 0.72x1 6.00 180 4.37 0.93x1 6.00 180 5.37 1.64x1 6.00 180 6.37 2.06x1 6.00 120 7.87 2.08x1 6.00 120 8.87 2.010x1 6.00 90 10.75 2.312x1 6.00 90 11.75 2.83x1-1/2 6.00 180 5.37 1.74x1-1/2 6.00 180 6.37 2.16x1-1/2 6.00 120 7.87 2.18x1-1/2 6.00 120 8.87 2.110x1-1/2 6.00 90 10.75 2.412x1-1/2 6.00 90 11.75 2.93x2 8.00 180 5.37 1.94x2 8.00 180 6.37 2.36x2 8.00 120 7.87 2.38x2 8.00 120 8.87 2.310x2 8.00 90 10.75 2.612x2 8.00 90 11.75 3.14x3 10.00 180 6.37 4.16x3 10.00 180 7.87 4.08x3 10.00 180 8.87 4.910x3 10.00 120 10.75 4.612x3 10.00 120 11.75 5.26x4 12.00 180 7.87 6.68x4 12.00 180 8.87 8.110x4 12.00 180 10.75 9.812x4 12.00 120 11.75 8.18x6 17.00 180 8.87 11.910x6 17.00 180 10.75 14.112x6 17.00 180 11.75 16.310x8 18.00 180 10.75 16.012x8 18.00 180 11.75 18.312x10 21.00 180 11.75 21.414x12 24.00 180 13.75 29.7 Saddles are manufactured with a plain-end pipe stub. Saddles with a spigot-end pipe stub are available, please inquire. No returns allowed.

Size(in.)

“L”(in.)

“Ø”(ang.)

“A”(in.)

Weight(lb.)

L

Ø

62

A

NOM. OUTLETSIZE

L

Ø

62

A

NOM. OUTLETSIZE

Page 59: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988553

Fig #62-45Saddle with Plain-End Pipe Stub, Reducing 45 Degree

1-1/2x1 6.00 180 6.09 0.72x1 6.00 180 6.43 0.93x1 6.00 180 7.22 1.64x1 6.00 180 7.93 2.06x1 6.00 120 9.43 2.08x1 6.00 120 10.85 2.010x1 6.00 90 12.35 2.312x1 6.00 90 13.77 2.83x1-1/2 7.00 180 7.72 1.74x1-1/2 8.00 180 8.43 2.16x1-1/2 8.00 120 9.93 2.18x1-1/2 9.00 120 11.35 2.110x1-1/2 9.00 90 12.85 2.412x1-1/2 9.00 90 14.27 2.93x2 8.00 180 8.34 1.94x2 8.00 180 9.05 2.36x2 9.00 180 10.55 2.38x2 9.00 120 11.97 2.310x2 10.00 90 13.47 2.612x2 10.00 90 14.89 3.14x3 11.00 180 10.13 4.16x3 11.00 180 11.80 4.08x3 11.00 180 13.22 4.910x3 11.00 120 14.72 4.612x3 11.00 120 16.14 5.26x4 13.00 180 12.55 6.68x4 13.00 180 13.97 8.110x4 13.00 120 15.47 9.812x4 13.00 120 16.89 8.18x6 19.00 180 15.35 11.910x6 19.00 180 16.85 14.112x6 19.00 120 18.27 16.310x8 22.00 180 18.22 16.012x8 22.00 180 19.64 18.314x8 22.00 180 23.37 24.0 Saddles are manufactured with a plain-end pipe stub. Saddles with a spigot-end pipe stub are available, please inquire. No returns allowed.

Size(in.)

“L”(in.)

“Ø”(ang.)

“A”(in.)

Weight(lb.)

L

Ø

62-45

A

NOM. OUTLETSIZE

L

Ø

62-45

A

NOM. OUTLETSIZE

Page 60: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988554

Fig #63Saddle with Flanged Outlet, Reducing

1-1/2x1 6.00 180 4.00 1.22x1 6.00 180 4.50 1.43x1 6.00 180 5.50 2.14x1 6.00 180 6.50 2.56x1 6.00 120 8.00 2.58x1 6.00 120 9.00 2.510x1 6.00 90 11.00 2.812x1 6.00 90 12.00 3.33x1-1/2 6.00 180 5.50 2.34x1-1/2 6.00 180 6.50 2.76x1-1/2 6.00 120 8.00 2.78x1-1/2 6.00 120 9.00 2.710x1-1/2 6.00 90 11.00 3.012x1-1/2 6.00 90 12.00 3.53x2 8.00 180 5.50 3.44x2 8.00 180 6.50 3.86x2 8.00 120 8.00 3.88x2 8.00 120 9.00 3.810x2 8.00 90 11.00 4.112x2 8.00 90 12.00 4.64x3 10.00 180 6.50 7.16x3 10.00 180 8.00 7.08x3 10.00 180 9.00 7.910x3 10.00 120 11.00 7.612x3 10.00 120 12.00 8.26x4 12.00 180 8.00 10.68x4 12.00 180 9.00 12.110x4 12.00 180 11.00 13.812x4 12.00 120 12.00 12.18x6 17.00 180 9.00 17.910x6 17.00 180 11.00 20.112x6 17.00 180 12.00 22.310x8 18.00 180 11.00 26.012x8 18.00 180 12.00 28.312x10 21.00 180 12.00 35.414x12 24.00 180 14.00 50.7 Flanged saddles are manufactured with flange bolt holes strad-dling vertical and horizontal centerlines. Please refer to Appen-dix B for flange assembly instructions. No returns allowed.

Size(in.)

“L”(in.)

“Ø”(ang.)

“A”(in.)

Weight(lb.)

L

Ø

63

A

FLANGED OUTLET SIZE

L

Ø

63

A

FLANGED OUTLET SIZE

Page 61: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988555

Fig #63-45Saddle with Flanged Outlet, Reducing 45 Degree

1-1/2x1 6.00 180 6.22 1.22x1 6.00 180 6.56 1.43x1 6.00 180 7.34 2.14x1 6.00 180 8.05 2.56x1 6.00 120 9.55 2.58x1 6.00 120 10.98 2.510x1 6.00 90 12.48 2.812x1 6.00 90 13.90 3.33x1-1/2 7.00 180 7.84 2.34x1-1/2 8.00 180 8.56 2.76x1-1/2 8.00 120 10.06 2.78x1-1/2 9.00 120 11.48 2.710x1-1/2 9.00 90 12.98 3.012x1-1/2 9.00 90 14.40 3.53x2 8.00 180 8.46 3.44x2 8.00 180 9.18 3.86x2 9.00 180 10.68 3.88x2 9.00 120 12.10 3.810x2 10.00 90 13.60 4.112x2 10.00 90 15.02 4.64x3 11.00 180 10.25 7.16x3 11.00 180 11.92 7.08x3 11.00 180 13.34 7.910x3 11.00 120 14.84 7.612x3 11.00 120 16.26 8.26x4 13.00 180 12.68 10.68x4 13.00 180 14.10 12.110x4 13.00 120 15.60 13.812x4 13.00 120 17.02 12.18x6 19.00 180 15.48 17.910x6 19.00 180 16.98 20.112x6 19.00 120 18.40 22.310x8 22.00 180 18.34 26.012x8 22.00 180 19.77 28.314x8 22.00 180 21.00 42.0

Flanged saddles are manufactured with flange bolt holes straddling vertical and horizontal centerlines. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“L”(in.)

“Ø”(ang.)

“A”(in.)

Weight(lb.)

L

Ø

63-45

A

FLANGED OUTLET SIZE

L

Ø

63-45

A

FLANGED OUTLET SIZE

Page 62: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988556

Fig #65Saddle, Blank 180 Degree Anchor

1 4.01-1/2 4.02 4.02-1/2 4.03 4.04 4.06 4.08 4.010 4.012 4.014 4.016 4.018 4.020 4.024 4.0

Longer than standard lengths available. No returns allowed.

Fig #64Saddle, Blank 180 Degree Wear

1 4.01-1/2 4.02 4.02-1/2 4.03 4.04 4.06 4.08 4.010 4.012 4.014 4.016 4.018 4.020 4.024 4.0 Longer than standard lengths available. No returns allowed.

Size(in.)

Size(in.)

“L”(in.)

“L”(in.)

64

L

1/4"

180°

64

L

1/4"

180°

65

L9/16"

180°

65

L9/16"

180°

Page 63: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988557

Fig #71Cross, Plain-End

3/4 2.38 0.91 3.38 1.31-1/2 3.88 2.02 4.38 2.72-1/2 4.88 3.73 5.38 4.64 6.38 8.06 7.88 13.38 8.88 22.610 10.88 35.912 11.88 58.514 13.75 61.216 14.75 66.518 16.25 78.520 17.75 93.124 21.75 113.0 Plain-end fittings are designed for butt-and-wrap joining. Butt-and-wrap kits are available, please see Fig.# 90. Crosses 3/4” to 12” are rated for 150 psi. Crosses 14” and larger are rated for 100 psi. Higher pressure ratings are available. No returns allowed.

Size(in.)

“A”(in.)

Weight(lb.)

Fig #70Cross, Bell-End

1 1.62 1.06 1.21-1/2 2.37 1.25 1.82 2.62 1.81 2.42-1/2 3.12 1.81 3.03 3.37 1.81 4.04 4.12 1.81 7.56 5.62 2.25 13.08 9.00 2.50 23.010 11.00 2.75 37.012 12.00 3.00 60.0

Bell-ends are designed to fit pipe with O.D.’s as shown in Fig.# 1. Please state O.D. or pipe manu-facturer when ordering bell-end fittings for pipe with different O.D.’s. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

CROSSES

70

a

b

c d

AB

71

a

b

c d

A

Page 64: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988558

Fig #73Cross, Combination Coupled or Reducing

Crosses may be ordered with a combination of end typessuch as flanged, reducing flanged, bell, reducing bell andplain-end or reducing plain-end.

When ordering Fig.# 73 combination-coupled or combinationcoupled reducing crosses please specify the endconfiguration by using the small letter call-outs for each end.

Example:A 12”x 12”x 6”x 6” Combination-coupled reducing cross,bell x flange x flange x bell would be specified with“a”, “b”, “c” and “d” ends as;a= bell, b=flange, c= flange, d= bell No returns allowed.

Fig #72Cross, Flanged, ANSI

1 3.5 4.01-1/2 4.0 6.52 4.5 11.02-1/2 5.0 17.03 5.5 19.04 6.5 26.06 8.0 42.08 9.0 73.010 11.0 105.012 12.0 156.014 14.0 182.016 15.0 210.018 16.5 234.020 18.0 286.024 22.0 380.0 Crosses 1” to 12” are rated for 150 psi. Crosses 14” and larger are rated for 100 psi. Higher pressure ratings are available. Fittings meet the centerline-to-flange-face dimen-sion of ANSI B16.5, 150 lb. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

Weight(lb.)

72

a

b

c d

A

73

a

b

c d

Page 65: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988559

Fig #81Lateral, 45 Degree, Plain-End

1 4.50 2.00 2.81-1/2 4.50 2.00 3.22 8.00 2.50 3.62-1/2 8.25 2.75 5.03 10.00 3.00 6.64 12.00 3.00 8.76 14.50 3.50 15.08 17.50 4.50 27.010 20.50 5.00 47.012 24.50 5.50 67.014 30.00 12.00 85.016 32.00 14.00 98.018 36.00 14.00 120.020 38.00 16.00 145.024 42.00 18.00 170.0

Plain-end fittings are designed for butt-and-wrap joining. Butt-and-wrap kits are available, please see Fig.# 90. Laterals 1” to 12” are rated for 150 psi. Laterals 14” and larger are rated for 100 psi. Higher pressure ratings are available. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

Fig #80Lateral, 45 Degree, Bell-End

1 4.50 2.00 1.06 2.81-1/2 4.50 2.00 1.25 3.22 8.00 2.50 1.81 3.62-1/2 8.00 2.50 1.81 4.43 10.00 3.00 1.81 6.64 12.00 3.00 1.81 8.76 14.50 3.50 2.25 15.08 17.50 4.50 2.50 27.010 20.50 5.00 2.75 47.012 24.50 5.50 3.00 67.0

Bell-ends are designed to fit pipe with O.D.’s as shown in Fig.# 1. Please state O.D. or pipe manufacturer when ordering bell-end fittings for pipe with different O.D.’s. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

“C”(in.)

Weight(lb.)

80

a b

c

ABC

A

81

a b

c

AB

A

LATERALS

Page 66: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988560

Fig #83Lateral, 45-Degree, Combination Coupled or Reducing

Laterals may be ordered with a combination of end typessuch as flanged, reducing flanged, bell, reducing bell andplain-end or reducing plain-end.

When ordering Fig.# 83 combination-coupled or combinationcoupled reducing crosses please specify the endconfiguration by using the small letter call-outs for each end.

Example:A 12”x 12”x 6” Combination-coupled reducing lateral,bell x bell x flange, would be specified asa= bell, b= bell, c= flange.

No returns allowed.

Fig #82Lateral, 45 Degree, Flanged

1 6.75 4.25 7.01-1/2 7.25 4.75 8.52 11.25 5.75 10.02-1/2 11.56 6.06 13.03 13.31 6.31 16.04 15.75 6.75 24.06 19.12 8.12 36.08 22.62 9.62 60.010 26.12 10.62 98.012 30.62 11.62 140.014 30.00 12.00 175.016 32.00 14.00 215.018 36.00 14.00 258.020 38.00 16.00 355.024 42.00 18.00 530.0

Laterals 1” to 12” are rated for 150 psi. Laterals 14” and larger are rated for 100 psi. Higher pressure ratings are available. Please refer to Appendix B for flange as-sembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

82

a b

c

AB

A

83

a b

c

Page 67: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988561

Fig #85Wye, True, Plain-End

1 2.38 3.38 2.81-1/2 2.88 3.88 3.22 3.38 4.38 3.62-1/2 3.88 4.88 5.03 3.88 5.38 6.64 4.88 6.38 8.76 5.88 7.88 15.08 6.88 8.88 27.010 9.88 12.88 47.012 11.38 14.88 67.014 12.75 17.25 85.016 14.75 19.75 98.018 16.75 21.75 120.020 18.75 24.75 145.024 21.75 28.75 170.0

Plain-end fittings are designed for butt-and-wrap joining. Butt-and-wrap kits are available, please see Fig.# 90. Wyes 1” to 12” are rated for 150 psi. Wyes 14” and larger are rated for 100 psi. Higher pressure ratings areavailable. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

Fig #84Wye, True, Bell-End

1 2.50 1.06 3.50 1.01-1/2 3.00 1.38 4.00 1.52 3.50 1.81 4.50 2.02-1/2 4.00 1.81 5.00 2.83 4.00 1.81 5.50 3.54 5.00 1.81 6.50 6.06 6.00 2.25 8.00 10.08 7.00 2.50 9.00 17.010 10.00 2.75 13.00 27.012 11.50 3.00 15.00 44.0

Bell-ends are designed to fit pipe with O.D.’s as shown in Fig.# 1. Please state O.D. or pipe manufacturer when ordering bell-end fittings for pipe with different O.D.’s. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

“C”(in.)

Weight(lb.)

84

a

b c

90°

A

B

C

B

85

a

b c

90°

A

B

WYES

Page 68: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988562

Fig #87Wye, True, Combination Coupled or Reducing

Wyes may be ordered with a combination of end typessuch as flanged, reducing flanged, bell, reducing bell andplain-end or reducing plain-end.

When ordering Fig.# 87 combination-coupled or combination coupled reducing wyes please specify the end configuration by using the small letter call-outs for each end.

Example:A 12”x 12”x 6” Combination-coupled reducing wye,bell x bell x flange, would be specified asa= bell, b= bell, c= flange.

No returns allowed.

Fig #86Wye, True, Flanged

1 2.50 3.50 7.01-1/2 3.00 4.00 8.52 3.50 4.50 10.02-1/2 4.00 5.00 13.03 4.00 5.50 16.04 5.00 6.50 24.06 6.00 8.00 36.08 7.00 9.00 60.010 10.00 13.00 98.012 11.50 15.00 140.014 13.00 17.50 175.016 15.00 20.00 215.018 17.00 22.00 258.020 19.00 25.00 355.024 22.00 29.00 530.0 Wyes 1” to 12” are rated for 150 psi. Wyes 14” and larger are rated for 100 psi. Higher pressure ratings are available. Please refer to Appendix B for flange assembly instructions. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

Weight(lb.)

86

a

b c

90°

A

B

87

a

b c

90°

Page 69: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988563

Fig #88-S/88-LP-Trap, Bell-End, Long and Short Radius

1 5.37 6.62 4.37 5.12 1.00 1.50 1.061-1/2 6.87 9.25 5.37 7.00 1.50 2.25 1.252 8.37 12.62 6.37 9.62 2.00 3.00 1.812-1/2 9.87 N.A. 7.37 N.A. 2.50 N.A. 1.813 11.37 17.12 8.37 12.62 3.00 4.50 1.814 14.37 21.62 10.37 15.62 4.00 6.00 1.816 19.88 29.37 13.88 20.37 6.00 9.00 2.258 29.00 37.87 21.00 25.87 8.00 12.00 2.50 Bell-ends are designed to fit pipe with O.D.’s as shown in Fig.# 1. Please state O.D. or pipe manufacturer when ordering bell-end fittings for pipe with different O.D.’s.No returns allowed.

Size(in.)

“A”Short

Radius88-S(in.)

“AA”Long

Radius88-L(in.)

“B”Short

Radius88-S(in.)

“BB”Long

Radius88-L(in.)

“C”Short

Radius88-S(in.)

“CC”Long

Radius88-L(in.)

“D/DD”Short/Long

Radius88-S/88-L

(in.)

SHORT RADIUS

CC

DD

AA

BB

DD

BB

88-L

P-TRAPS

SHORT RADIUS

A

B

D

B

C

D

88-S

Page 70: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988564

Fig #89Drain, Floor

8x2 2-3/8 12.08x3 3-1/2 12.08x4 4-1/2 12.08x6 6-5/8 12.08x8 8-5/8 12.0

Floor drain includes removable grate and bowl assembly. Removable grate and drain bowl may be ordered sepa-rately. No returns allowed.

Size(in.)

“A”(in.)

Weight(complete)

(lb.)

FLOOR DRAIN

FLOOR DRAIN

REMOVABLE GRATE(45) 1/2" DIA. HOLES

9 1/2"

8 5/8"

2" 1 1/4"

A

7 3/4"

4"REF.

89

Page 71: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988565

Fig #91Adhesive Kit

1 10 x1-1/2 6 102 4 72-1/2 3 53 3 54 2 26 1/2 18 1/2 110 1/2 112 x 1

Adhesive kit includes resin, catalyst, spatula and instructions.No returns allowed.

PipeSize(in.)

No. Joints Per Kit3 Ounce 5 Ounce

Fig #90Field Weld Kit, Butt-and-Wrap, Vinyl Ester

23468101214161820243036

Butt-and-wrap field weld kits are pre-cut fiberglass mat and roving in plastic bags. Each kit will do (1) joint. Store only in dry environment. Kits are intended for use only by persons qualified in the butt-and-wrap joining technique of fiberglass pipe. Glass kits are shipped in individual pack-ages. Resin and catalyst are shipped in bulk. Special handling and packaging fees may apply to resin and catalyst. No returns allowed.

PipeSize(in.)

BUTT-AND-WRAP FIELD WELD KITS

ADHESIVE KITS

Small Tool Kit Includes:1) 3” Roller1) Brush5) Mixing Cups5) Stirring Sticks1) Catalyst Measure

Large Tool Kit Includes: 2) 3” Rollers 3) Brushes 10) Mixing Cups 10) Stirring Sticks 1) Syringe

Field weld kits available in pressure ratings up to 150 psi. Available with glass only or glass, resin and catalyst. Tool kits also available.

Page 72: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988566

Fig #99Dome, End

6 6.00 3.38 1.50 3.08 8.00 3.88 1.50 4.510 10.00 4.38 1.50 6.212 12.00 4.88 1.50 6.814 14.00 5.38 1.50 9.316 16.00 5.88 1.50 12.018 18.00 6.38 1.50 14.420 20.00 6.88 1.50 23.424 24.00 7.88 1.50 34.530 30.00 9.38 1.50 45.036 36.00 10.88 1.50 61.042 42.00 12.00 1.50 71.048 48.00 13.50 1.50 81.054 54.00 15.00 1.50 91.0

End domes are designed for butt-and-wrap joining onto pipe.End domes 6” through 12” are rated for 150 psi. End domes 14” and larger are rated for 100 psi. Higher pressure ratings are available. Please see Fig.# 90 for butt-and-wrap kits. No returns allowed.

Size(in.)

“A”(in.)

“B”(in.)

“C”(in.)

Weight(lb.)

END DOME

99

A

B

C

END DOME

Page 73: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988567

APPENDIX A

SPIGOT DIMENSIONS

1/2” 0.840 0.825 0.840 0.820 0.805 1.000 1.000 0.8753/4” 1.050 1.035 1.050 1.050 1.015 1.125 1.000 0.8751” 1.315 1.297 1.315 1.290 1.275 1.188 1.188 1.0631-1/2” 1.900 1.878 1.900 1.871 1.856 1.375 1.375 1.2502” 2.375 2.350 2.375 2.344 2.328 1.937 1.488 1.3632-1/2” 2.875 2.850 2.875 2.845 2.830 1.937 1.500 1.3753” 3.500 3.474 3.500 3.469 3.454 1.937 1.650 1.5254” 4.500 4.469 4.500 4.459 4.444 1.937 1.937 1.8125” 5.563 5.530 5.563 5.520 5.505 1.937 1.937 1.8126” 6.625 6.588 6.625 6.580 6.565 2.375 2.375 2.2508” 8.625 8.581 8.625 8.580 8.565 2.625 2.635 2.50010” 10.750 10.702 10.750 10.690 10.675 2.875 2.875 2.75012” 12.750 12.698 12.750 12.690 12.675 3.125 3.125 3.00014” 3.250 3.250 3.00016” 3.750 3.750 3.50018” 4.000 4.000 3.75020” 5.000 5.000 4.75024” 5.000 5.000 4.75030” 4.250 4.250 4.00036” 4.562 4.562 4.312

Nom.PipeDia.

PipeO.D.

“A” “D” “L” “BL”“B”

Ref. Max. FittingMin. Flange

SPIGOT DIMENSIONS

BL

AB D

L

Page 74: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988568

APPENDIX BFILAMENT WOUND

FLANGE ASSEMBLY INSTRUCTIONS

SCOPEThese instructions present recommendations on the proper assembly of RAM Fiberglass, Inc. filament-wound flanges drilled to ANSI B 16.5, 150lb. Recommendations are also given on gasket material, bolt lengths, and proper sequence of bolt torque to obtain an effective seal. For recommendations on the adhesive bonding of RAM Fiberglass, Inc. flanges to fiberglass pipe please refer to “Instructions for Adhesive Bonded Bell and Spigot Joints”.

1.0 GASKETSRAM Fiberglass filament-wound flanges in sizes of 1/2” to 12” require the use of a full face, 150 lb. gasket. Flanges 14” and larger are available with flat face for use with full face gaskets or o-ring. In either case the elastomer must be suitable for the pressure, temperature and chemical fluid in the system. For full face gaskets RAM recommends the use of a 1/8” elastomer with a Shore A durometer hardness of 60 ±5. For o-ring gaskets RAM Fiberglass recommends an elastomer with a Shore A durometer hardness of 45-55 ±5. Dimensions of o-ring gaskets for RAM Fiberglass flanges are shown in Table 1.

Nominal Flange Cross-Sectional Mean Diameter Diameter Diameter (in.) (in.) (in.) 14 7/16 15-7/8 16 7/16 18-3/8 18 7/16 19-3/4 20 7/16 22 24 7/16 26-3/8 30 9/16 32-3/4 36 9/16 39-1/4

2.0 BOLTS, NUTS AND WASHERSThe recommended type of hex head bolts, nuts and washers for RAM Fiberglass Fig#15 flanges is shown in Table 2. If all-thread studs are used, add the thickness of the nut and washer plus the length of three threads to the bolt lengths shown.

TABLE 1O-RING DIMENSIONS

APPENDIX B FILAMENT-WOUND

FLANGE ASSEMBLY INSTRUCTIONS

SCOPE

These instructions present recommendations on the proper assembly of RAM Fiber-glass, Inc. filament-wound flanges drilled to ANSI B 16.5, 150lb. Recommendations are also given on gasket material, bolt lengths, and proper sequence of bolt torque to obtain an effective seal. For recommendations on the adhesive bonding of RAM Fiber-glass, Inc. flanges to fiberglass pipe please see “Instructions for Adhesive Bonded Bell and Spigot Joints”.

1.0 GASKETS

RAM Fiberglass filament-wound flanges in sizes of 1/2” to 12” require the use of a full face, 150 lb. gasket. Flanges 14” and larger are available with flat face for use with full face gaskets or o-ring. In either case the elastomer must be suitable for the pressure, temperature and chemical fluid in the system. For full face gaskets RAM recommends the use of a 1/8” elastomer with a Shore A du-rometer hardness of 60 ±5 For o-ring gaskets RAM Fiberglass recommends as elastomer with a Shore A durome-ter hardness of 45-55 ±5. Dimensions of o-ring gaskets for RAM Fiberglass flanges are shown in Table 1.

TABLE 1 O-RING DIMENSIONS

Nominal Flange Cross-Sectional Mean Diameter Diameter Diameter (in.) (in.) (in.)

14 7/16 15 7/8 16 7/16 18 3/8 18 7/16 19 3/4 20 7/16 22 24 7/16 26 3/8 30 9/16 32 3/4 36 9/16 39 1/4

2.0 BOLTS, NUTS AND WASHERS

The recommended type of hex head bolts, nuts and washers for RAM Fiberglass Fig#15 flanges is shown in Table 2. If all-thread studs are used, add the thickness of the nut and washer plus the length of three threads to the bolt lengths shown.

RAM Fiberglass, Inc.

5236 Faraday Court Chino, CA 91710 Phone: 909-627-9822 Fax: 909-627-9885 Web: ramfiberglass.com

Page 75: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988569

For the assembly of two flanges not shown in Table 2, the hex head bolt length may be calculated by adding the total of the thickness of the two flanges being joined plus the gasket thickness, plus 2 times (2X) the washer thick-ness plus the thickness of the nut plus the length of three threads. Refer to the RAM Fiberglass Product Catalog for thickness of all RAM Fiberglass flanges.

(1) Regular Hex Head Bolts, ANSI B 18.2.1-1972(2) Type A Plain, Narrow Series, ANSI B18.22.1-R-1981 (Dimensions agree with “SAE Standard” and ANSI/ ASTM Specification F 436)(3) Regular Hex Nuts, ANSI B 18.2.2-1972

3.0 PRIOR TO JOINING FLANGES• Check all flanges for seal ring damage especially those inside the bolt circle. Flanges with damaged inner seal rings should be replaced.• Check gaskets for damage. Any gasket found with cuts, irregular surfaces or other damage which may effect the seal must be replaced.

TABLE 2HEX HEAD BOLTS, NUTS AND WASHERS FOR FIG# 15 FLANGES,

ANSI B 16.5, 150 LB DRILLING

1/23/41

1-1/22

2-1/234568101214161820243036

1/21/21/21/25/85/85/85/83/43/43/47/87/811

1-1/81-1/81-1/41-1/41-1/2

44444448888121212161620202832

2-1/22-1/22-1/2

333

3-1/23-1/23-1/24-1/2

55-1/25-1/26-1/2

77-3/49-3/4

10-1/48-1/28-1/2

22

2-1/22-1/22-3/4

33-1/43-1/23-3/4

44-1/44-3/4

55-1/25-3/46-1/47-1/2

87-1/47-3/4

1.061.061.061.061.311.311.311.311.471.471.471.751.752.002.002.252.252.502.503.00

.12

.12

.12

.12

.12

.12

.12

.12

.16

.16

.16

.16

.16

.16

.16

.16

.16

.16

.16

.16

.44

.44

.44

.44

.55

.55

.55

.55

.64

.64

.64

.75

.75

.86

.86

.97

.971.061.061.28

Bolt Lengths (1)

(All dimensions in inches)

Nom.Flange

SizeBoltDia.

No.Of

Bolts

Filament-WoundTo

Filament-Wound

Filament-WoundTo

SteelWasher (2)

O.D.Washer (2)

Thk.Hex Nut (3)

Thk.

Page 76: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988570

• Check the surfaces on all mating flanges. Clean or repair as needed.• Lubricate all bolt threads.• O-rings must be lubricated prior to assembly. Use a non-petroleum based lubricant andlubricate both the

o-ring and o-ring groove.

4.0 FLANGE ASSEMBLY

Assemble the flanges being joined using a washer under all bolt heads and nuts. All bolt threads must be lubricated to obtain proper torque results. Finger tighten all nuts and check for proper alignment of flange faces.

Misalignment of flange faces will cause bending stresses at the flange and flange joint and damage may result. Correct any misalignment prior to applying torque.

5.0 APPLYING TORQUE

Torque must be applied to all nuts in increments and sequence as shown in Table 3. Proceed through the tightening sequence applying torque in increments shown in Table 3 until the recommended torque is attained. Recheck the torque on each bolt in the same sequence as bolts previously tightened may have relaxed during the torque sequence.

6.0 SEALING AGAINST RAISED FACE STEEL FLANGES, VALVES ANDOTHER FLANGES

Ram Fiberglass filament-wound 150 lb. flanges can be bolted to raised face steel flanges provided bolt torque is applied in increments and sequence as indicated in Table 3. A full face gasket should be used, see 1.0. To prevent damage, flanges rated less than 150 lb. require the use of a spacer ring to fill the annular space created by the raised surface between the filament-wound flange face and the flange or valve face.

Valves are often supplied with elastomeric sealing surfaces built into the body of the valve. Due to the wide variety of sealing surfaces and faces on valves RAM Fiberglass recommends a full face gasket (see 1.0) at all valve connections.

Page 77: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988571

TABLE 3BOLT TORQUE, TORQUE INCREMENT AND BOLTING SEQUENCE

FIG# 15 FLANGES DRILLED TO ANSI B 16.5, 150LB

1/23/41

1-1/22

2-1/234568

101214161820243036

55555555

101010101010101010151515

2020202020202020303030303050506060757575

TABLE 3 BOLT TORQUE, TORQUE INCREMENT AND BOLTING SEQUENCE

FIG# 15 FLANGES DRILLED TO ANSI B 16.5, 150LB

Nom.Flange

Size(in.)

1/23/41

1 1/2 2

2 1/2 34568

101214161820243036

TorqueIncrement

(ft.-lb.)

55555555

202020202020202020151515

Recommended Torque For Full Pressure Seal

(ft.-lb.)

2020202020202020303030303050506060757575

4 BOLT FLANGE

8 BOLT FLANGE

12 BOLT FLANGE 16 BOLT

FLANGE 20 BOLT FLANGE

28 BOLT FLANGE

32 BOLT FLANGE

5236 Faraday Court Chino, CA 91710 Phone: 909-627-9822 Fax: 909-627-9885 Web: ramfiberglass.com

27

Nom.Flange Size

(in.)

TorqueIncrement(ft.-lbs.)

RecommendedTorque For FullPressure Seal

(ft.-lbs.)

Page 78: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988572

Nom. Total Nom. Total Pipe Press. Nom. Wall Pipe Press. Nom. Wall Size Rating O.D. I.D. Thk. Weight Size Rating O.D. I.D. Thk. Weight(in.) (psi) (in.) (in.) (in.) (lb./ft.) (in.) (psi) (in.) (in.) (in.) (lb./ft.)

APPENDIX C

PIPE DATA

3/8 150 0.67 0.38 0.15 0.2

1/2 150 0.84 0.50 0.17 0.2

3/4 150 1.05 0.73 0.16 0.3

1 150 1.32 1.06 0.13 0.4

1-1/4 150 1.66 1.22 0.22 0.5

1-1/2 150 1.90 1.62 0.14 0.6

2 150 2.38 2.08 0.15 1.0

2-1/2 150 2.88 2.38 0.25 1.5

3 150 3.50 3.13 0.19 1.7

4 150 4.50 4.13 0.19 2.2

6 150 6.63 6.26 0.19 3.2

8 150 8.63 8.27 0.18 4.2

10 150 10.75 10.28 0.24 5.8

12 150 12.75 12.27 0.24 6.9

14 50 14.40 14.00 0.20 7.8 100 14.40 14.00 0.20 7.8 125 14.48 14.00 0.24 9.4 150 14.48 14.00 0.24 9.4

16 50 16.40 16.00 0.20 8.8 100 16.40 16.00 0.20 8.8 125 16.48 16.00 0.24 10.6 150 16.56 16.00 0.28 12.5

Notes:

1.) Wall thickness includes minimum 40 mil liner. Other liners are available including 110 mil and abrasion resistant liners. Please consult RAM Fiberglass for other liners.

2.) Please contact RAM Fiberglass for pipe pricing. Other sizes and pressure ratings, including pipe rated for full vacuum service is available.

3.) Weight/ft. is based on plain end pipe.

4.) Standard factory lengths are: 5 feet for 3/8” size; 10 feet for sizes 1/2”, 3/4”, 1”, 1-1/4” and 1-1/2”; 20 feet for sizes 2” to 6” and 40 feet for larger sizes.

5.) We will cut pipe to your specified length.

18 50 18.40 18.00 0.20 10.0 100 18.48 18.00 0.24 12.0 150 18.64 18.00 0.32 16.2 20 50 20.40 20.00 0.20 11.0 100 20.48 20.00 0.24 13.3 150 20.64 20.00 0.32 17.9 24 50 24.40 24.00 0.20 13.2 100 24.56 24.00 0.28 18.6 150 24.80 24.00 0.40 26.9 30 50 30.48 30.00 0.24 19.8 100 30.64 30.00 0.32 26.6 36 50 36.48 36.00 0.24 23.7 100 36.80 36.00 0.40 39.9 42 50 42.48 42.00 0.24 27.6 100 42.88 42.00 0.44 51.1 48 50 48.56 48.00 0.28 36.8 100 49.04 48.00 0.52 42.5 54 50 54.64 54.00 0.32 47.4 100 55.12 54.00 0.56 83.6 60 50 60.64 60.00 0.32 52.6 100 61.20 60.00 0.60 99.5

Page 79: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988573

APPENDIX DFILAMENT WOUND PIPE

PHYSICAL AND MECHANICAL PROPERTIES

Product Data: Filament Wound Pipe - ASTM D-2996 Epoxy Vinyl Ester Resin - Pigmented Gray

ELASTIC AND STRENGTH PROPERTIES OF GLASS FILAMENT REINFORCED WALL

Hoop Tensile (Based on loading of pipe hydrostatically)

Ultimate (porosity) .............................................................. 20,000 psi Yield ....................................................................................12,800 psi Allowable ...............................................................................6,700 psi Modulus of Elasticity ......................................................3,600,000 psi

Tensile (Based on loading of pipe as tension member) Ultimate (rupture) ................................................................12,200 psi Yield ......................................................................................5,000 psi Allowable ...............................................................................4,000 psi Modulus of Elasticity ......................................................1,800,000 psi

Thermal Properties

Coefficient of Thermal Expansion ........................0.0000085 in./in./°F. Thermal Conductivity ......................................... 2.3 BTU•in/(hr•ft2•°F)

Flexural (Based on loading pipe as a beam)

Ultimate (rupture) ........................................................ 15,700 psi Yield ..............................................................................6,100 psi Allowable ......................................................................4,000 psi Modulus of Elasticity .............................................. 1,700,000 psi

Torsion (Based on loading of pipe as a shaft in torsion)

Ultimate Shear (rupture) ............................................. 16,200 psi Allowable Shear ............................................................ 5,500 psi Shear Modulus .........................................................750,000 psi

Compression (Based on loading of pipe as a “short compression member”)

Ultimate (rupture) ............................... 11,200 psi Yield .....................................................7,000 psi Allowable .............................................3,700 psi Modulus of Elasticity .....................1.400,000 psi

RAM fittings are designed with the following minimum safety factors:

Rupture ..........................10:1 Porosity ............................3:1 Yield ..............................1.5:1

Page 80: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988574

APPENDIX EEPOXY FILAMENT WOUND PIPE

PHYSICAL AND MECHANICAL PROPERTIES

Product Data: Filament Wound Pipe and Pipe Fittings Epoxy Resin - Pigmented Black

ELASTIC AND STRENGTH PROPERTIES OF GLASS FILAMENT REINFORCED PIPE WALL

PIPE:RAM Fiberglass, Inc. epoxy pipe is filament-wound using continuous filament glass roving impregnated with epoxy resin and contains a nominal 0.050” thick reinforced liner in pipe sizes to 12”. Epoxy pipe is designed for a constant working pressure of 150 psi and is available in pipe sizes of ½” to 12” diameter. Pipe and pipe fittings have a maximum service temperature of 250°F in most applications.

FITTINGS AND FLANGES:A complete line of socket, threaded and flanged pipe fittings and flanges is available in all pipe sizes. Flanges are drilled and faced to ANSI B 16.5, 150 lb. standards.

JOINTS:RAM Fiberglass, Inc. epoxy pipe and pipe fittings may be joined using either a bell and spigot adhesive bonded joint using a two-part epoxy adhesive or threaded or flanged connections.

Typical Moduli of Elasticity and Allowable Stress Values at 70°F

Modulus Of Allowable Elasticity Stress

Hoop Tensile/ ASTM D 1599 4.6 x 106 psi 8,200 psi

Axial Tensile/ ASTM D 2105 1.6 x 106 psi 3,000 psi

Beam Flexural 2.0 x 106 psi 3,700 psi

Axial Compression/ ASTM D 695 2.3 x 106 psi 3,700 psi

Coefficient of Thermal Expansion................................0.0000085 in./in./°F

Thermal Conductivity....................................................1.70 Btu•in/(hr•ft²•°F)

Page 81: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988575

APPENDIX FSPECIFICATION FOR FILAMENT-WOUND

REINFORCED FIBERGLASS PIPE

SCOPE

This specification covers manufacturing, fabricating, furnishing, delivering & testing filament- wound, glass fiber reinforced thermosetting epoxy vinyl ester resin pipe designated RTRP 12E (Type 1, Grade 2, Class E, epoxy vinyl ester resin liner reinforced) in accordance with ASTM D-2996.

PIPEAll sizes

Pipe shall be filament-wound, glass fiber reinforced, thermosetting epoxy vinyl ester resin pipe RTRP 12E (Type 1, Grade 2, Class E, epoxy vinyl ester resin liner reinforced) per ASTM D-2996. Pipe shall be supplied in sections of maximum length.

Pipe shall be machine made and consist of the following laminate element layers, resin impregnated, and bonded integrally to form a monolithic pipe wall:

a.) A epoxy vinyl ester resin base internal corrosion resistant and abrasion resistant liner consisting of C-veil or synthetic veil with a nominal thickness of 40 mils.

b.) A structural wall of epoxy vinyl ester resin impregnated and bonded continuous Type E glass fiber filament strands machine would helically.

c.) A resin rich external surface containing an ultraviolet inhibitor.

Total pipe wall thickness shall be designed to withstand the internal and, if applicable, external design pres-sures and temperatures. Total pipe wall thickness shall be subject to approval by the Engineer.

JOINTSAll sizes Pipe and Fittings

Style and design shall be approved by the engineer.

Standard joining for pipe sizes 1/2-inch through 12-inch shall be adhesive bonded bell & spigot. Standard joining for pipe sizes 14-inch through 24-inch shall be adhesive bonded bell & spigot or plain-end for butt and wrap. Standard joining for pipe sizes 30-inch and larger shall be plain-endfor butt-and-wrap or bell and spigot with single, or double, o-ring.

The cutting of pipe, the dressing of cut pipe ends, the preparation of joining surfaces andthe bonding and laminating techniques shall be per the instruction of the pipe and fittingmanufacturer.

Page 82: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988576

Specialized equipment, tools, adhesives, curing equipment and information such as flange bolt torques and assembly instructions shall be supplied or approved by the pipe and fitting manufacturer.

FLANGESAll Sizes

Flanges shall be filament-wound construction manufactured from the same materials as the pipe. Flanges shall be socket type for adhesive bonding and shall have raised sealing surfaces integral to the flange face.

Flanges, except for thickness, shall have the same number, position and size of bolt holes, and flange out-side diameter as ANSI B16.5, 150 lb. Compression molded flanges or flanges of other construction shall not be permitted.

FITTINGSAll Sizes

Fittings shall be filament-wound construction with internal corrosion resistant 40 mil. liner manufactured from the same materials as the pipe. Fittings shall also have a U.V. inhibitor.

Fittings shall be supplied with sockets for adhesive bonded bell and spigot joining, flanged, or plain-end for butt-and-wrap joining, depending on fitting size (see JOINTS).

Inside diameter of fittings shall match inside diameter of connecting pipe. Elbows shall be smooth radius with no miter cuts/welds unless approved by Engineer.

BOLTS

ANSI B18.2.1, 1972 Regular Hex Head Bolts - material per project requirements.

NUTS

ANSI B18.2.2, 1972 Regular Hex Nuts - material per project requirements.

WASHERS

ANSI B27.2, 1965 Type A Plain, Narrow Series (same as SAE Standard) - material per project requirements.

NOTE: Use washers under all bolt heads and nuts.

GASKETS

Full face, 1/8-inch thick material suitable for application with a Shore A durometer of 60 +/- 5.

RECEIVING

Inspect shipping cradles, padding, hold down straps and any other protection for displacement or failure.

Page 83: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988577

Inspect for evidence of pipe movement, either axial or lateral, during shipment. Inspect pipe exterior and interior for shipping damage.

Record and report any observation of shipping damage to carrier’s agent immediately and request in-spection report. Note any damage on carrier’s freight bill before carrier leaves.

HANDLING

Use handling equipment sufficiently strong to handle the load. Pipe weights per foot can be found in the RAM Fiberglass, Inc. product catalog.

Lift pipe using canvas or nylon belts of adequate strength. Belts must be 4-inch minimum width.

Straight continuous lengths (40-foot maximum) of pipe are to be lifted at two points spaced 10 feet apart at center of pipe.

Prefabricated pipe assemblies generally require two point lifting. Please consult RAM Fiberglass, Inc.

STORING

All pipe shall be placed on flat and level ground and supported by a minimum of three 4-inch wide sup-ports (4X4’s) equally spaced along pipe lengths.

Pipe to 16-inch diameter may be stacked four high. Do not nest smaller pipe into larger pipe when stacking. Do not stack pipe 18-inch and larger.

Store all pipe in a way that will avoid point loading from rock, nails, etc.

Fittings should be left in their shipping boxes until ready for use.

Store all adhesives in a cool dry place until ready for use.

TESTING

Field testing of the pipe system is best and most safely accomplished using a non-compressible fluid such as water.

Testing with air or any gas is not recommended.

Provide vents for air and vapor removal at all high points in the pipe system.

Test the system hydrostatically at 1-1/2 times the operating pressure of the system for a period of four hours.

Page 84: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988578

INDEX

ADAPTERS Page Bell x Victaulic (Fig. 5) ................................. 4 Female, Bell x Thread (Fig. 3) ..................... 3 Male, Bell x Thread (Fig. 4) ......................... 4

BUSHINGS Reducing, Bell-Outlet (Fig.9) ....................... 5 Reducing, Threaded-Outlet (Fig.10) ............ 6

CAPS Pipe, Bell (Fig. 11) ....................................... 6 Pipe, Thread (Fig. 11-T)............................... 6

COUPLINGS Pipe (Fig. 1) ................................................. 1 Maintenance (Fig. 1-R) ................................ 1 Threaded, Half (Fig. 2-L/2) .......................... 2 Threaded, Extra Long (Fig. 2-XL) ................ 2 Threaded, Long (Fig. 2-L) ............................ 2 Threaded, Extra Long, Half (Fig. 2-XL/2) .... 3 Threaded, Short (Fig. 2-S) ........................... 3

CROSSES Bell-End (Fig. 70) ....................................... 57 Combination-Coupled or Reducing (Fig. 73) ..................................... 58 Flanged ANSI (Fig. 72) .............................. 58 Plain-End (Fig. 71) ..................................... 57

DOME, END Plain-End (Fig. 99) ..................................... 66

ELBOWS 90° Bell-End Short Radius (Fig. 20-S) ........................ 21 Long Radius (Fig. 20-L) ......................... 21 Combination-Coupled Short Radius ANSI Flange x Bell-End (Fig. 23-S) ............ 23 Flange x Plain-End (Fig. 24-S) .......... 24 Long Radius ANSI Flange x Bell-End (Fig. 23-L) ............. 23 Flange x Plain-End (Fig. 24-L) ........... 24 Flanged ANSI Short Radius (Fig. 22-S) ........................ 22 Long Radius (Fig. 22-L) ......................... 22 Plain-End Short Radius (Fig. 21-S) ........................ 21 Long Radius (Fig. 21-L) ......................... 21

ELBOWS 45° Page Bell-End (Fig. 30) ....................................... 25 Combination-Coupled ANSI Flange x Bell-End (Fig. 33) .................... 27 Flange x Plain-End (Fig. 34) .................. 27 Flanged ANSI (Fig. 32) .............................. 26 Plain-End (Fig. 31) ..................................... 26

ELBOWS, SPECIAL ANGLES Bell-End, 22 1/2° (Fig. 28) ......................... 24 Bell-End, 30° (Fig. 29) ............................... 25

FIELD WELD KITS Butt-and-wrap (Fig. 90) .............................. 65 Adhesive (Fig. 91) ..................................... 65

FLANGES Assembly Instructions - Appx.B ................. 68 Blind 150 lb. (Fig. 16) ..................................... 17 25 lb. (Fig.16-25) ................................... 18 Bolt Torques - Appx.B ................................ 71 Socket 25 lb. (Fig. 15-25) .................................. 15 150 lb. (Fig. 15) ....................................... 9 300 lb. (Fig. 14) ....................................... 8 Heavy Duty, 150 lb. (Fig. 15-HD) ............11 Orifice, 150 lb. (Fig. 19) ......................... 20 Reducing, 150 lb. (Fig. 18) .................... 19 Vanstone, 25 lb. (Fig. 15-VS-25) ........... 16 Vanstone, 150 lb. (Fig. 15-VS) .............. 13 Spacer, 150 lb. (Fig. 15-S) ......................... 12 Stub 25 lb. (Fig. 15-A-25) ............................... 16 150 lb. (Fig. 15-A) .................................. 10 Vanstone, 25 lb. (Fig. 15-A-VS-25) ........ 17 Vanstone, 150 lb. (Fig. 15-A-VS) ........... 14 Threaded Flange (Fig. 17) ......................... 18

FLOOR DRAINS (Fig. 89) ...................................... 64

LATERALS Bell-End, 45° (Fig. 80) ............................... 59 Combination or Reducing, 45° (Fig. 83) .... 60 Flanged, 45° (Fig. 82) ................................ 60 Plain-End, 45° (Fig. 81) ............................. 59

Page 85: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988579

NIPPLES Page Pipe-Spigot end (Fig. 8) .................................5 Pipe-Thread End (Fig. 6) ...............................4 Pipe-Thread x Spigot (Fig. 7) ........................5

P-TRAPS Bell-End, Short Radius (Fig. 88-S) ..............63 Bell-End, Long Radius (Fig. 88-L) ...............63

PIPE Dimensional Data - Appx. C ........................72 Physical Properties - Epoxy, Appx. E ..........74 Physical Properties - Vinylester, Appx. D ....73 Spigot Dimensions - Appx. A .......................67 Specifications - Appx. F ...............................75

PLUGS Fitting (Fig. 13) ..............................................7 Fitting, Threaded (Fig. 13-T) ..........................7 Pipe (Fig. 12) .................................................7

REDUCERS Bushing (See Bushings) Concentric Tapered Body Bell-End (Fig. 50) .....................................36 Plain-End (Fig. 50-PE) .............................37 Combination-Coupled Bell x Flange (Fig. 55) .............................42 Plain-End x Flange (Fig. 55) ....................42 Flange x Bell (Fig. 57) .............................44 Flange x Plain (Fig. 57) ...........................44 Flanged ANSI (Fig. 53) ............................40 Eccentric Tapered Body Bell-End (Fig. 51) .....................................38 Plain-End (Fig. 51-PE) .............................39 Combination-Coupled Bell x Flange (Fig. 56) .............................43 Plain-End x Flange (Fig. 56) ....................43 Flange x Bell (Fig. 58) .............................45 Flange x Plain (Fig. 58) ...........................45 Flanged ANSI (Fig. 54) ................................41

SADDLES Blank (180°) Wear (Fig. 64) ..........................................56 Anchor (Fig. 65) .......................................56 Reducing Bell-Outlet, 90° (Fig. 61) ..........................50 Bell-Outlet, 45° (Fig. 61-45) .....................51 Flange-Outlet, 90° (Fig. 63) .....................54 Flange-Outlet, 45° (Fig. 63-45) ................55

Page Plain-End Outlet, 90° (Fig. 62).................52 Plain-End Outlet, 45° (Fig. 62-45) ...........53 Threaded, NPT (Fig. 60) ..........................46 Threaded, NPT, 45° (Fig. 60-45) .............47 Threaded, 316 S.S. Bushing, 90° (Fig. 60-SS) .............................................48 Threaded, 316 S.S. Bushing, 45° (Fig. 60-SS-45) ........................................49

TEES Bell-End (Fig. 40) .........................................28 Combination-Coupled Bell x Bell x Flange (Fig. 43) ....................29 Plain x Plain x Flange (Fig. 43) ................29 Flange x Bell x Bell (Fig. 44) ....................30 Flange x Plain x Plain (Fig. 44) ................30 Flange x Bell x Flange (Fig. 45) ...............31 Flange x Plain x Flange (Fig. 45) .............31 Flange x Flange x Bell (Fig. 46) ...............32 Flange x Flange x Plain (Fig. 46) .............32 Flanged ANSI (Fig. 42) ................................29 Plain-End (Fig. 41) .......................................28 Reducing Bell-End (Fig. 47) .....................................33 Plain x Plain x Bell (Fig. 47) .....................33 Plain x Plain x Plain (Fig. 47) ...................33 Flanged ANSI (Fig. 48) ............................34 Reducing, Combination Coupled Bell x Bell X Flange (Fig. 49) ...................35 Plain x Plain x Flange (Fig. 49) ................35

WYES Bell End, True (Fig. 84) ................................61 Combination-Coupled (Fig. 87) ...................62 Reducing (Fig. 87) .......................................62 Flanged, True (Fig. 86) ................................62 Plain-End, True (Fig. 85) .............................61

Page 86: Important Notice - RAM Fiberglass

Product Catalog August 1, 2008

Ram Fiberglass Inc. 5236 Faraday Court Chino, CA 91710 (909) 627-9822 FAX (909) 627-988580

TERMS AND CONDITIONS OF SALE

1. Quotations and sales of RAM Fiberglass, Inc. products are F.O.B. point of shipment and title and risk of loss pass to Buyer upon delivery of products to carrier. RAM Fiberglass, Inc. must be notified of any claims for shortages or errors in shipment or changes within 10 days after receipt of products by Buyer. Unless otherwise agreed, freight terms will be collect from shipping point.

2. All orders are subject to approval and acceptance by RAM Fiberglass, Inc. An order requiring immediate attention or airfreight shipment may be charged an expediting fee which will be quoted at time of order acceptance.

3. All prices are consumer net and are subject to change without notice. Prices are based on standard domestic packaging. Unless otherwise agreed, the invoice price will be those in effect at time of shipment.

4. Invoices are due and payable 30 days from day of shipment. Any account over 45 days will be placed on credit hold and will be subject to interest charges at the maximum rate allowed by law. In the event Buyer delays shipment beyond the date on which RAM Fiberglass, Inc. could have shipped the goods, Buyer shall make full payment therefore within thirty (30) days of such date.

5. If the Buyer fails to fulfill the terms of payment of any order between the Buyer and RAM Fiberglass, Inc., RAM Fiber-glass, Inc. may defer further shipments until such payments are made or may cancel any or all orders unshipped. RAM Fiberglass, Inc. will be entitled to collect all expenses incurred in collecting delinquent accounts, including attorney’s fees.

6. All sales are final. Certain unused standard fittings may be returned for credit against future orders with prior written approval from RAM Fiberglass, Inc. Products authorized for return will be shipped freight prepaid at Buyers expense and will be subject to 25% restocking charge. Fittings noted “NO RETURNS ALLOWED”, piping assemblies and specialty items “made-to-order”, or manufactured from non-standard resin systems are not returnable.

7. RAM Fiberglass, Inc. warrants the products to be free from defects in material and workmanship for a period of one year from the date of shipment. RAM’s sole obligation and Buyers exclusive remedy in connection with the products shall be limited, at RAM’s option, to either repair or replace the product or products not conforming to this warranty, F.O.B. Factory. Any claims must be made in writing within the warranty period. This warranty is the sole warranty covering the products and RAM Fiberglass, Inc. makes no other warranty of any kind, whether express, implied or statutory, and all implied warranties of merchantability and fitness for a particular purpose are hereby disclaimed by RAM Fiberglass, Inc. and excluded from this warranty. In no event shall RAM Fiberglass, Inc. be liable for consequential, compensatory, punitive or incidental damages. This warranty shall not apply to products which have been repaired or altered by other than authorized representatives of RAM Fiberglass, Inc. or to damage or defects caused by accident, misuse, vandalism, Acts of God, corrosion, erosion, normal wear and tear, improper selection by Buyer or other causes beyond the control of RAM Fiberglass, Inc.

8. Ram Fiberglass, Inc. shall be under no obligation or liability to Buyer for any direct, indirect or consequential damages arising out of delay in performance and non-performance of the terms hereof or any order caused directly or indirectly, by fire, explosion, accident, floods, labor trouble or shortage, war, act of or authorized by any government, inability to obtain suitable material, equipment, fuel, power of transportation, or Act of God, or arising from contingencies, occurrences or causes beyond the control of RAM Fiberglass, Inc.. Quantities so affected by any such circumstances may be eliminated without liability, but other terms of sale remain unaffected.

9. Unless otherwise specifically agreed by RAM Fiberglass, Inc., in writing, all goods will be manufactured to standard commercial tolerances in effect at date of manufacture. Orders for special tolerances or other than standard catalog designs are subject to additional charges. RAM Fiberglass, Inc. reserves the right to request payment from Buyer in advance of RAM’s com-mencement of manufacture.

10. Buyer shall reimburse RAM Fiberglass, Inc. for all sales, use, excise or occupation taxes or other taxes imposed on RAM’s sale of the goods to Buyer. To be exempt, Buyer must submit any appropriate tax exemption certificate to RAM Fiberglass, Inc. prior to date of shipment of goods.