6
ITPA Toronto November 2006 1 /6 Impact of connection length inhomogeneity on heat flux to limiters Euratom TORE SUPRA Impact of local change in connection length on limiter power load E TORE SUPRA / DSM / DRFC hendrih, Association Euratom-CEA, adarache, 13108 St Paul lez Durance

Impact of local change in connection length on limiter power load

Embed Size (px)

DESCRIPTION

Impact of local change in connection length on limiter power load. EQUIPE TORE SUPRA / DSM / DRFC Ph. Ghendrih, Association Euratom-CEA, CEA Cadarache, 13108 St Paul lez Durance. Ergodic Divertor : short cuts to the core. Long connection length large power flux. Short connection length - PowerPoint PPT Presentation

Citation preview

Page 1: Impact of local change in  connection length  on limiter power load

ITPA Toronto November 2006 1 /6Impact of connection length inhomogeneity on heat flux to limitersImpact of connection length inhomogeneity on heat flux to limiters

Euratom TORE SUPRA

Impact of local change in

connection length on limiter power load

Impact of local change in

connection length on limiter power load

EQUIPE TORE SUPRA / DSM / DRFC

Ph. Ghendrih, Association Euratom-CEA,

CEA Cadarache, 13108 St Paul lez Durance

EQUIPE TORE SUPRA / DSM / DRFC

Ph. Ghendrih, Association Euratom-CEA,

CEA Cadarache, 13108 St Paul lez Durance

Page 2: Impact of local change in  connection length  on limiter power load

ITPA Toronto November 2006 2 /6Impact of connection length inhomogeneity on heat flux to limitersImpact of connection length inhomogeneity on heat flux to limiters

Euratom TORE SUPRA

Ergodic Divertor : short cuts to the core

Ergodic Divertor : short cuts to the core

CORE Short connection lengthsmall power flux

Long connection lengthlarge power flux

Page 3: Impact of local change in  connection length  on limiter power load

ITPA Toronto November 2006 3 /6Impact of connection length inhomogeneity on heat flux to limitersImpact of connection length inhomogeneity on heat flux to limiters

Euratom TORE SUPRA

Linear analysis : long connection length = larger mode

Linear analysis : long connection length = larger mode

ki

Sheath stabilisation

ShiftShift

Page 4: Impact of local change in  connection length  on limiter power load

ITPA Toronto November 2006 4 /6Impact of connection length inhomogeneity on heat flux to limitersImpact of connection length inhomogeneity on heat flux to limiters

Euratom TORE SUPRA

Impact of long connection length

potential density

Long connection length

Page 5: Impact of local change in  connection length  on limiter power load

ITPA Toronto November 2006 5 /6Impact of connection length inhomogeneity on heat flux to limitersImpact of connection length inhomogeneity on heat flux to limiters

Euratom TORE SUPRA

Density drop = low flux

250

200

150

100

50

0

240200160

12

8

4

0

n

150100500(r-a)/s

1.0

0.8

0.6

0.4

0.2

0.0

S, mean y=192 y= 64 y=128

Page 6: Impact of local change in  connection length  on limiter power load

ITPA Toronto November 2006 6 /6Impact of connection length inhomogeneity on heat flux to limitersImpact of connection length inhomogeneity on heat flux to limiters

Euratom TORE SUPRA

0.5

0.4

0.3

0.2

0.1

0.0

16012080400(r-a)/s

2

3

4

567

10

2n

mean y=128

Long connection length

low heat flux to limiter

Long connection length

low heat flux to limiter