IMPACT OF INSTRUMENTION TUBE IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL FAILURE ON NATURAL CIRCULATION DURING SEVERE CIRCULATION DURING SEVERE ACCIDENTS ACCIDENTS M. Khatib-Rahbar, A. Krall, Z. Yuan, M. Zavisca Energy Research, Inc. Rockville, Maryland 20852 & R. Lee U.S. Nuclear Regulatory Commission Washington, D. C. 20555 February 2009

IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

New ReactorsNew Reactors

IMPACT OF INSTRUMENTION TUBE IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL FAILURE ON NATURAL

CIRCULATION DURING SEVERE CIRCULATION DURING SEVERE ACCIDENTSACCIDENTS

M. Khatib-Rahbar, A. Krall, Z. Yuan, M. ZaviscaEnergy Research, Inc.

Rockville, Maryland 20852&

R. LeeU.S. Nuclear Regulatory Commission

Washington, D. C. 20555

February 2009

Page 2: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

2New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

OutlineOutline

Background

TMI-2 Observations

Modeling & Analysis of Instrumentation Tube Failure TMI-2 PWR with Inverted U-Tube Steam Generator

Summary & Conclusions

Page 3: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

3New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

BackgroundBackground

During a severe accident in a PWR where system pressure remains elevated, there is a great propensity for large recirculation of steam & hydrogen between the damaging reactor core & the upper plenum.

In case of PWRs with inverted U-tube steam generators (i.e., most of operating and new plants), also between upper plenum, hot leg, and steam generator tubes.

Page 4: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

4New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Background (Cont.)Background (Cont.)

PWRs with Once-Through Steam Generators (TMI-2)

Page 5: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

5New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Background (Cont.)Background (Cont.)

PWRs with Inverted U-Tube Steam Generators

Page 6: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

6New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

TMITMI--2 Observations2 Observations

Closure of ERV (PORV) occurred at 6:22:37 am (i.e., 142 minutes into the accident) -Stopping any flow from reactor to containment

Radiation monitors inside containment started to show increased levels starting at 6:39 am (16 minutes and 23 seconds later)

Tubes)ationInstrument (i.e., Paths LeakageOther

Page 7: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

7New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

TMITMI--2 Observations2 Observations

~150 – 160 minutes

Page 8: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

8New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Location of Radiation MonitorsLocation of Radiation MonitorsSection B-B

[Henry (May 2008)]

Page 9: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

9New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Location of Radiation MonitorsLocation of Radiation Monitors

Section C-C

[Henry (May 2008)]

Page 10: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

10New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Measured Radiation Measured Radiation Near InNear In--Core Instrumentation PanelCore Instrumentation Panel

[Henry (May 2008)]

Page 11: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

11New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Measured Radiation Measured Radiation In vicinity of the Containment DomeIn vicinity of the Containment Dome

[Henry (May 2008)]

Page 12: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

12New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

TMITMI--2 In2 In--Core Instrumentation DesignCore Instrumentation Design

W

X

Y

Z

Control rod assembly location

Incore instrument location

Fuel assembly

Reactor vessel

Thermal shield

Core barrel

•177 fuel assemblies

•15x15 (225) with 208 fuel rods

•16 control rod guide tubes

•An instrumentation guide tube (in the center of the each assembly)

Page 13: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

13New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

TMITMI--2 Lower Head Core Support Structure2 Lower Head Core Support Structure

Fuel assembly grid pad

Instrument support plateGrid forging

Flow distributor plateLower grid

Instrument tube

penetration detail

Lower grid shell

Clamping ring

Incore instrument

guide tube (typ)

Elliptical flow distributor plate

Core

5.1 cm

49.5cm5.1 cm1.3 cm

34.3 cm

15.3 cm2.5 cm

13.3 cm18.4 cm

Plate thicknesses and associated distances

Core support assembly

Page 14: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

14New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

TMITMI--2 Instrumentation Guide Tube & 2 Instrumentation Guide Tube & Instrumentation ThimbleInstrumentation Thimble

(c) Instrument tube

Upper end fitting mixing cup Coolant

Instrument tube

Instrument thimble

Assembly end fitting grill plate

Retainer sleeve

Coolant

Instrument tube

Instrument thimble

SPND, T/C, or background

Calibrate tube

Page 15: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

15New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

TMITMI--2 In2 In--Core Detector & Guide TubeCore Detector & Guide Tube

0.236

0.318 cm

0.635 cm

0.742 cm

I.D. = 1.311 cm

I.D. = 1.372 cm

In-Core Detector and Guide Tube Cross Section

Miniature Ion Chamber Probes

Inserted Through This Tube (This central passage is at the

containment pressure)

Stainless Steel 304L1/2 in. SCH. 80

Guide Pipe

Inconel-clad Instrument Thimble

Center Calibration Tube

Sheathed Self Powered Neutron

Detectors (7)

Sheathed Background

Detector

Sheathed Thermocouple

Coolant

Page 16: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

16New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Modeling ApproachModeling Approach Use MELCOR 1.8.6 Parametric in order to enable understanding of the

impact of uncertainties Characteristic time of instrumentation tube and

associated structure:

D = outside diameter of the thimble tubed = inside diameter of the calibration tubeC = effective specific heatρ= effective density of the entire instrumentation tube

structure, including the sensors, andh = heat transfer coefficient to thimble tube.

hD

dDC4

22

Page 17: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

17New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Modeling Approach (Cont.)Modeling Approach (Cont.)

D = 0.742 cm (7.42 x 10-3m)d = 0.236 cm (2.36 x 10-3m)

C ~ 540 J/kg-K (Inconel)ρ ~ 8200 kg/m3

50 W/m2-K < h < 80 W/m2-K

Therefore, adequate to assume thermal response of tubes is on the same time scale as steam inside fuel assemblies. (More detailed models can represent the instrumentation tubes as a separate core structure)

minutes 2.5~ to minute 1.5 from ranges

Page 18: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

18New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Modeling Approach (Cont.)Modeling Approach (Cont.)

Page 19: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

19New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Modeling Approach (Cont.)Modeling Approach (Cont.)

Failure of Instrumentation Tubes - Introduced additional flow paths in the core region that open to containment when steam temperature reaches user defined “threshold” (e.g., melting temperature of Inconel)

Plugging of Failed Instrumentation Tubes – Either:

Core reflood (freezing of molten debris) due pump restart (TMI-2) or accumulator injection

“Significant” core damage resulting in self-plugging of tubes (i.e., specified fraction of UO2 converted into particulate debris)

Page 20: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

20New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Modeling Approach (Cont.)Modeling Approach (Cont.)

?

?

Failure by PerforationFailure by Melting

Page 21: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

21New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2)2) Base Case - failure of instrumentation tubes

assumed to occur at 1300K (low temperature failure) Starting at 137 until 174 minutes, all 52 instrumentation

tubes are calculated fail (but tubes of each computational ring are considered to vent at different axial levels as failure threshold in different levels are reached).

For all computational rings, the lowest level is the last to fail and in case of the outermost ring, this occurs only a few seconds before the time of the RCP-B restart

Plugging of failed instrumentation tubes occurs upon core reflood (restart of RCP-B at 174 minutes)

Page 22: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

22New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2) –– Cont.Cont.

mass flow rate of steam and hydrogen through the failed instrumentation tubes

Page 23: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

23New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2) –– Cont.Cont.

Net mass flow of hydrogen through failed instrumentation tubes

Page 24: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

24New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2) –– Cont.Cont.

Recirculation flow rates (core-to-upper plenum) with & without inst. tube failure

Page 25: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

25New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2) –– Cont.Cont.

Fluid densities relative to bypass at top axial level of the core and bypass

Page 26: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

26New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2) –– Cont.Cont.

Gas temperature profile in the RPV (at 133 minutes)

Page 27: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

27New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2) –– Cont.Cont.

Gas temperature profile in the RPV (at 151 minutes)

Page 28: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

28New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2) –– Cont.Cont.

Gas temperature profile in the RPV (at 166 minutes)

Page 29: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

29New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2) –– Cont.Cont.

Page 30: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

30New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2) –– Cont.Cont.

Page 31: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

31New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2) –– Cont.Cont.

Page 32: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

32New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2) –– Cont.Cont.

Cumulative in-vessel hydrogen production

Page 33: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

33New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2) –– Sensitivity StudiesSensitivity Studies

Sensitivity to instrumentation tube plugging time (duration of RPV venting)

Page 34: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

34New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2) –– Sensitivity StudiesSensitivity Studies

Sensitivity to instrumentation tube failure temperature

Page 35: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

35New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2) –– Sensitivity StudiesSensitivity Studies

Sensitivity of control rod guide tube temperature to failure temperature & venting duration

Page 36: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

36New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (TMIResults (TMI--2) 2)

_________________________________________________________

144 174 214Time in minutes

Page 37: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

37New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

PWRs with UPWRs with U--Tube Steam Generators Tube Steam Generators Natural circulation between core-to-upper

plenum, and upper plenum, to hot leg, and steam generator tubes redistributes the core generated heat (decay and chemical) to: Hot leg nozzles Hot leg pipe Surge-line (most affected by flow through PORV) Steam generator tubes

At high pressure, creep-rupture of reactor coolant system boundary at these locations: Beneficial EffectBeneficial Effect (“natural” thermal fuse that results in

reactor coolant system depressurization) – eliminating potential for early containment failure due to “Direct Containment Heating”.

Detrimental EffectDetrimental Effect – Creep rupture of SG tubes, can result in release of radioactivity to environment (“Containment Bypass”)

Page 38: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

38New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Modeling ApproachModeling Approach MELCOR 1.8.6 Tube failure modeling identical to that of TMI-2

Page 39: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

39New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

InIn--Core Instrumentation TubesCore Instrumentation Tubes

Page 40: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

40New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

InIn--Core Instrumentation TubesCore Instrumentation Tubes

Page 41: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

41New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

InIn--Core Instrumentation TubesCore Instrumentation Tubes

Typical Westinghouse plant (Zion):

58 instrumented fuel assemblies

Diameter of inner part of instrumentation tubes (which is at containment pressure) is 5 mm

Therefore, flow area resulting from failure of all tubes is ~1.15 x 10-3 m2 or ~5 times larger than TMI-2 (2.27 x 10-4 m2).

Page 42: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

42New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Accident ScenarioAccident Scenario

Station Blackout Scenario Base case – assumes the steam generator safety

valve “sticks open” (depressurizing the secondary system) after lifting on one of the steam generators (on the pressurizer loop). This results in the most limiting tube-wall temperature.

Sensitivity case assuming the steam generators remain at the safety relief valve pressure.

Page 43: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

43New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (PWR with UResults (PWR with U--Tube SGs) Tube SGs) –– Base CaseBase Case

Primary System Pressure

Page 44: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

44New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (PWR with UResults (PWR with U--Tube SGs) Tube SGs) –– Base CaseBase CaseCont.Cont.

mass flow rate of steam and hydrogen through the failed instrumentation tubes

Page 45: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

45New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Net mass flow of hydrogen through failed instrumentation tubes

Results (PWR with UResults (PWR with U--Tube SGs) Tube SGs) Base Case Base Case -- Cont.Cont.

Page 46: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

46New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (PWR with UResults (PWR with U--Tube SGs) Tube SGs) Base Case Base Case -- Cont.Cont.

Recirculation flow rates (core-to-upper plenum) with & without inst. tube failure

Page 47: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

47New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (PWR with UResults (PWR with U--Tube SGs) Tube SGs) Base Case Base Case -- Cont.Cont.

Counter-current coolant mass flow rate in the pressurizer hot leg

Page 48: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

48New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (PWR with UResults (PWR with U--Tube SGs) Tube SGs) Base Case Base Case -- Cont.Cont.

Vapor temperature at the hot leg nozzles

Page 49: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

49New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (PWR with UResults (PWR with U--Tube SGs) Tube SGs) Base Case Base Case -- Cont.Cont.

Pressurizer surge Line structure and damage parameter

Page 50: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

50New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (PWR with UResults (PWR with U--Tube SGs) Tube SGs) Base Case Base Case -- Cont.Cont.

Hot Leg structure and damage parameter

Page 51: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

51New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Steam generator tube structure and damage parameter (pressurizer loop)

Results (PWR with UResults (PWR with U--Tube SGs) Tube SGs) Base Case Base Case -- Cont.Cont.

Page 52: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

52New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (PWR with UResults (PWR with U--Tube SGs) Tube SGs) Base Case Base Case -- Cont.Cont.

Total In-Vessel Hydrogen Generation

Page 53: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

53New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (PWR with UResults (PWR with U--Tube SGs) Tube SGs) Sensitivity to SG Secondary Pressure Sensitivity to SG Secondary Pressure -- Cont.Cont.

SG S/RV on pressurizer loop

Stuck openSG S/RV Operating

Recirculation flow rates (core-to-upper plenum)

Page 54: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

54New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (PWR with UResults (PWR with U--Tube SGs) Tube SGs) Sensitivity to SG Secondary Pressure Sensitivity to SG Secondary Pressure -- Cont.Cont.

Vapor temperature at the hot leg nozzles

Page 55: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

55New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Results (PWR with UResults (PWR with U--Tube SGs) Tube SGs) Sensitivity to SG Secondary Pressure Sensitivity to SG Secondary Pressure -- Cont.Cont.

Steam generator tube structure and damage parameter

Page 56: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

56New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Summary & ConclusionsSummary & Conclusions

Failure of instrumentation tubes resulting in venting of steam and hydrogen to containment have a marked impact of natural circulation:

TMI-2 (One-through SGs)

Venting does not impact reactor coolant system pressure due to smaller/thinner instrumentation tubes.

Core-to-upper plenum recirculation generally suppressed

Structures (e.g., control rod guide tube) temperature lowered by as much as 100K

Total in-vessel hydrogen generation not significantly affected.

Page 57: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

57New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Summary & Conclusions Summary & Conclusions -- ContCont

PWR with Inverted U-Tube SGs

Large venting through failed instrumentation tubes sufficient topartially depressurize the reactor coolant system

Core-to-upper plenum recirculation suppressed significantly until the time of fuel relocation into lower plenum water and system repressurization.

Hot-leg to steam generator recirculation suppressed significantly (by a factor ~3) due to failure of instrument tubes

Temperatures of nozzles, surge line, hot leg pipe, and steam generator tubes significantly reduced (at least by as much as 500K) due to failed instrumentation tubes.

Failure of instrumentation tubes shifts the location of RCS failure to hot leg nozzles.

Page 58: IMPACT OF INSTRUMENTION TUBE FAILURE ON NATURAL

58New ReactorsNew ReactorsFebruary 2009 Impact of Instrumentation Tube Failure on Natural Circulation

Uncertainties: Incipient instrumentation tube failure criterion Failure location, and Extent of available area for steam and hydrogen venting Plugging of failed tubes due to damage progression.

Nonetheless, over the range of parametrics, analyses show: Degradation in core-to-upper plenum natural circulation is

significant Significant impact in terms of reduction of the potential for

steam generator tube rupture for PWRs with inverted U-tubes SGs.

All previous studies have over estimated the likelihood of induced SGTR

Summary & Conclusions Summary & Conclusions -- ContCont