1
Results: 289 patients’ preoperative CTA reviewed (1148±328images/patient ). Mean CIA narrowest diameters 12.8±4mm(R), 12.9±3.9mm (L) Mean EIA narrowest diameter 7.7±1.6mm(R), 7.8±1.7mm(L) Tortuosity ratios 0.8±0.1(R, L), range 0.40-0.91 TASC II C/D lesion PAD in 31 patients (10.7%) No in hospital and 30-day complications were recorded @ mean follow-up (26 months): 30 reinterventions in 26 patients (8.9%), and 22 (7.6%) non AAA-related deaths R-EIA diameter ≤5mm (P=.0012, OR 5.2, 95% CI 1.73-15.57), and TASC C/D lesion PAD (P=.03, OR 3.06, 95% CI 1.02-9.20) were significantly related to reinterventions. TORTUOSITY WAS NOT A SIGNIFICANT PREDICTOR OF ADVERSE EVENTS Vascular and Endovascular Surgery Division, Department of Surgery “P Stefanini” Policlinico Umberto I - “Sapienza” University of Rome ILIAC ARTERIES MORPHOLOGICAL FEATURES AS DETERMINANT OF OUTCOME AFTER STANDARD EVAR PROCEDURES Pasqualino Sirignano, Francesco Speziale, Laura Capoccia, Wassim Mansour, Nunzio Montelione, Francesco Setacci, Giuseppe Galzerano and Carlo Setacci Objectives: To evaluate the impact of iliac arteries’ diameters, tortuosity, and peripheral vascular asset on outcome of elective EVAR for AAA in 2 high volume centers’ experience. Material and Methods: A retrospective study conducted on a prospectively collected database between 2010 and 2012. Factors considered as potentially influencing outcomes were: iliac axes’ diameters and tortuosity and presence of TASC II C/D femoro-popliteal disease. Outcome measures were reintervention and mortality rates at follow-up. Conclusion: Our experience suggests that diameters of access vessels and the presence of PAD could affect the outcome of EVAR. t SD P R-Torurtuosity 0.38 0.10 .70 L -Tortuosity 0.30 0.99 .76 R-CIA Diameter 0.22 0.61 .83 L -CIA Diameter 0.23 0.46 .81 R-EIA Diameter 1.91 0.16 .05 L -EIA Diameter 0.77 0.16 .44

ILIAC ARTERIES MORPHOLOGICAL FEATURES AS DETERMINANT … · Results: 289 patients’ preoperative CTAreviewed(1148±328images/patient). MeanCIAnarrowest diameters 12.8±4mm(R),12.9±3.9mm(L)

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ILIAC ARTERIES MORPHOLOGICAL FEATURES AS DETERMINANT … · Results: 289 patients’ preoperative CTAreviewed(1148±328images/patient). MeanCIAnarrowest diameters 12.8±4mm(R),12.9±3.9mm(L)

Results:289 patients’ preoperative CTA reviewed (1148±328images/patient).Mean CIA narrowest diameters 12.8±4mm(R), 12.9±3.9mm (L)Mean EIA narrowest diameter 7.7±1.6mm(R), 7.8±1.7mm(L)Tortuosity ratios 0.8±0.1(R, L), range 0.40-0.91TASC II C/D lesion PAD in 31 patients (10.7%)No in hospital and 30-day complicationswere recorded@ mean follow-up (26 months):30 reinterventions in 26 patients (8.9%), and 22 (7.6%) non AAA-related deaths

R-EIA diameter ≤5mm (P=.0012, OR 5.2, 95% CI 1.73-15.57), and TASC C/D lesionPAD (P=.03, OR 3.06, 95% CI 1.02-9.20) were significantly related to reinterventions.

TORTUOSITYWASNOTASIGNIFICANTPREDICTOROFADVERSEEVENTS

Vascular and Endovascular Surgery Division, Department of Surgery “P Stefanini”Policlinico Umberto I - “Sapienza” University of Rome

ILIACARTERIESMORPHOLOGICALFEATURESASDETERMINANTOFOUTCOMEAFTERSTANDARDEVARPROCEDURESPasqualino Sirignano, FrancescoSpeziale,LauraCapoccia,WassimMansour,Nunzio Montelione,FrancescoSetacci,GiuseppeGalzerano andCarloSetacci

Objectives:To evaluate the impact of iliac arteries’ diameters, tortuosity, and peripheralvascular asset on outcome of elective EVAR for AAA in 2 high volume centers’experience.

Material and Methods:A retrospective study conducted on a prospectivelycollected database between 2010 and 2012.Factors considered as potentially influencing outcomeswere: iliac axes’ diameters and tortuosity and presence ofTASC II C/D femoro-popliteal disease.Outcome measures were reintervention and mortalityrates at follow-up.

Conclusion:Our experience suggests that diameters of access vesselsand the presence of PAD could affect the outcome ofEVAR.

t SD PR-Torurtuosity 0.38 0.10 .70L-Tortuosity 0.30 0.99 .76R-CIADiameter 0.22 0.61 .83L-CIADiameter 0.23 0.46 .81R-EIADiameter 1.91 0.16 .05L-EIADiameter 0.77 0.16 .44