View
290
Download
7
Tags:
Embed Size (px)
DESCRIPTION
IKS Photovoltaic
Citation preview
Photovoltaik
IKS
IKS Photovoltaik GmbH
An der Kurhessenhalle 16b
34134 Kassel / Germany
Phone ++49 / (0)561 / 9 53 80 50
Fax ++49 / (0)561 / 9 53 80 51
www.iks-photovoltaik.de
Photovoltaic – Trainingsystem for vocational and advanced training
plus module stand. Using a dimmable spotlightwhich is vertically as well as horizontally movablefixed to an outrigger, seasonal daily curves caneasily be simulated.
Additional options are the change of slope angleand the simulation of the influence of irradiation andtemperature on the characteristic curve of a PV-module.
To ensure a reproducibility of measurements andnot to depend on the weather, a PV-modulesimulator was developed, which exactly simulatesthe behaviour of a PV-module. The short circuitcurrent can be adjusted.
What a pupil ortrainee can workout on his own inpractice orientedlabscale experim-ents, is trans-ferable to realsystems withoutproblems.
The Solar branchis one of theimportant growthmarket of thef u r t u r e . T h enumber of jobsg r o w s , t h ed e m a n d o fspecialists andexecutive staffsi n c r e a s e scontinuous.For this reasonwor ldwide thevocational andadvanced trainingin the field ofphotovoliiac willbecome more andmore important.
Development
Application
Construction
In cooperation with the ISET - Institut für SolareEnergieversorgungstechnik e. V. (now: Frauen-hofer Institut für Windenergie und Energiesystem-technik IWES) in Kassel the company IKS Photo-voltaik developed the Photovoltaic-TrainingsystemSolartrainer profi.
The PV-Trainingsystem is suited for the instructionschools, vocational training Schools, training
centres, evening classes and universities.Supported learning objectives can be electrical andsystem engineering , construction, mode ofoperation, connecting and installation of PV-plants.It can be used both to the supplementarydemonstration of lessons and courses as well as forthe use in practical training
The system consists of individual plugin units eachwith components for different experimentalarrangements. The plugin units are put in therackside and connected according to the demand.The conception of the system allows indoor andoutdoor experiments.Indoor experiments are easily possible amongothers because of the system included PV-module
at
.
IKSPhotovoltaik
IKSSOLARTRAINERProfi
IKSPhotovoltaik
IKS
FlexibleThe modular conception of thesystem allows the selection ofthe plug-in units and compo-nents for the different trainingobjectives.The at any time possibleenlargement and integration ofnew technology assure a systemthat is always state of-the-art.
Instructional materialsAn experimental instruction aswell as two developed trainingsessions are available.(at the moment only in Germanlanguage)
Experiments
The basic principles of photovoltaics considering the influence ofdifferent parameters can also be imparted as the application of directconnected small systems, the mains behaviour of stand alonesystems and the especially for craftsmen very important line poweredoperation mode:
Characteristic curve of a diode, respectively adiode series
Characteristic curve of a solar module (I/U)and (U/P), MPP
Characteristic curve of a solar module (I/U)depending on irradiation
Characteristic curve of a solar module (I/U)depending on temperature
Power output of a solar module dependingon the angle of incidence of the light
Simulation: Power output of a solar moduldepending on the position of the sun (morningto evening / winter- and summertime)
Series connection of solar modules
Parallel connection of solar modules
Series connection of solar modules andshadowing without bypass-diode
Series connection of solar modules andshadowing with bypass-diode
operation moDifferent operation modes and directions of electric energypower flow. Calculation of the efficiency (inverter)
Stand alone systems DC and AC. Different
Integration of outdoor solar module
�
�
�
�
�
�
�
�
�
�
�
�
�
e
Grid parallel de
operation modes
The listing does not contain all experimentswhich are possible to carry out.The possibility of carrying out the experiments isdepending on the equipment.Technical changes reserved 2011-02
SOLARTRAINERProfi
IKSPhotovoltaik
IKSSOLARTRAINERProfi
ST 01Solar ModuleConnection Indoor
For connecting the solarmodule of “ST 14 modulestand” to the socket on thefront. The two front socketsof the schematically shownsolar module can beconnected to a variable load(e.g. ST 20 B). Measuring ofvoltage and current.
ST 02Solar Module Simulated
Solar module simulator for theexact simulation of a solarmodule.Short circuit current can beadjusted in steps or variably.Parallel and series connectionpossible.Switchable bypass diode.Mains connection 230 V / 50-60Hz.Open circuit voltage 23.1 V,short circuit current 0 -1.5 A,rated power 24 Wp.
ST 03Generator Terminal Box
For the parallel connectionof 4 solar modules/simulators each via onediode onto one output.Overvoltage protectionWithout function. Max.current per input 24 V/3 A.DC-disconnector.
ST 07AC Load Connection
For connection to the mains (via"ST 13 Mains connection) or toan inverter island grid (“ST 06 /ST 06 A”) and operation ofalternating current loads ofmax. 450 W.Available versions:230 V / 50-60 Hz115 V / 60 Hz
ST 04Solar Charge Controller
For monitoring of the state ofcharge state of the battery.Controls the loading processand the connection anddisconnection of loads(low voltage disconnection).Operation status on LCDdispay.Rated voltage 12 V/max 8 A..
ST 05Inverter Grid Connection
Transforms direct currentinto sinusoidal alternatingcurrent, single-phase feed-in,line-commutated. Input28 - 50 V DC, MPP-tracking.AC power approx. 110 W.Available versions:230 V / 50 Hz230 V / 60 Hz115 V / 60 Hz
O / ST 05 D
(ST 05 O /ST 05 D)(ST 05 D)(ST 05 D)
ST 06 RInverter Island Grid
Transforms direct current intorectangular alternating current foroperation of an island gridsystem. Input 12 V DC/8 A,output 230 V / 50 Hz.AC power approx. 100 W.
ST 06 SInverter Island Grid
Transforms direct currentinto sinusoidal alternatingcurrent for operation of anisland grid system.Input 12 V DC/8 A.AC power approx. 100 W.Available versions:230 V / 50 Hz230 V / 60 Hz115 V / 60 Hz
IKSPhotovoltaik
IKSSOLARTRAINERProfi
ST 13Mains Connection
Three-phase AC connection forconnection of the public grid viaa 5-pole CEE coupling 16 Ato the training system.Adapter cable for single-phaseavailable.
ST 09Battery Connection
For the connection of "ST 21solarbattery" to "ST 04 chargecontroller".
ST 10Electric Meter
Single-phase electronic ACmeterfor measuring of the generatedsolar energy.Display of current power, kWh,measurement duration, inputtingof tariff possible.Available versions:230 V / 50 Hz230 V / 60 Hz115 V / 60 Hz
ST 11Input /Supply Meter
Single-phase electronic ACmeters for measuring of thesolar energy fed into the gridand for measuring of theenergy drawn from the grid.Display same as ST 10.Available versions:230 V / 50 Hz230 V / 60 Hz115 V / 60 Hz
ST 08DC Load Connection
For connection to "ST 04solar charge controller" andoperation of direct currentloads 12 V / max. 8 A.
ST 12Automatic Insulation Unit
For monitoring single-phasepower feeding systems. Itprevents uncontrolled islandeffects following failure orshutdown of the publicelectricity supply.Operating voltage 230 V / 50 Hz
ST 14Module Stand
For the illumination of a10 W solar module bymeans of a 500 Wdimmable halogen spotlight.The inclination of the solarmodule and the height anddistance of the spotlight tothe solar module areAdjustable.The inclination of thespotlight can also be alteredby fine adjustment.The solar module can beswung to simulate thesun's path during the day.Power supply 230 V / 50-60Hz.
IKSPhotovoltaik
IKSSOLARTRAINERProfi
ST 16Diode Series Connection
To perform the basicexperiments "Characteristiccurve of a diode" and"Characteristic curve ofa diode series connection”.Power supply external24 V DC by "ST 27 PowerSupply".
ST 17Shunt
For measuring current upto 1.5 A as voltage drop atthe shunt resistance.E.g. for measurements ingrid parallel operationcircuits using anoscilloscope.
ST 19Set of Safety Test Leadswith movable laboratory stand
Highly flexible safety-test leadswith 4 mm plugs. Contactsgold-plated brass/hard copper,inclusive movable laboratorystand with 2 brackets suppliedwith total 42 holding fingers.Lockable wheels, height 1.45 m.
ST 18Set of Safety Test Leads
Highly flexible safety-test leadswith 4 mm plugs. Contactsgold-plated brass/hard copper,inclusive wall bracket with21 holding fingers.
ST 20 ACAC Load
Panel 160 W bulb.Standard plug socketwith switch.Available versions:230 V / 50-60 Hz115 V / 60 Hz
ST 15Solar ModuleConnection Outdoor
For connection of themodule "ST 22 SolarModule Outdoor " orsimilar to the socket onthe front. The solarmodule is connectedto the two front socketsof the schematicallyshown solar module.
ST 20 ACAC Load
Panel 260 W bulb.Standard plug socketwith switch.Available versions:230 V / 50-60 Hz115 V / 60 Hz
ST 20 ACAC Load
Panel 39 W Energy-saving lamp.Standard plug socketwith switch.Available versions:230 V / 50-60 Hz115 V / 60 Hz (15 W)
IKSPhotovoltaik
IKSSOLARTRAINERProfi
ST 21Solar Battery
Closed lead-gel batteryespecially for storing solarenergy. Connected via"ST 09 battery connection"to "ST 04 solar chargecontroller" for operation ofan island grid with storage.12 V / 27 Ah C100.
ST 22Solar Module Outdoor
Solar module for outdoorexperiments. Angle ofinclination adjustable,can be read off on a large
degree scale.Power 55 Wp.
Operation with “ST 15Solar module connection
outdoor”.
ST 24Set Multimeter
Particularly robust, dustand waterproof IP 67.Automatic range selection,large display.DC / AC max. 1000 V,max. 10 A.
ST 27Power Supply
For the power supply of"ST 16 diode series connection".Control range 0 - 30 V DC/ 0-2 A.Power supply:115-230 V / 50-60 Hz.
ST 23DC Meter
Electronic DC meter formeasuring direct current loads.Using in load cricuits.Display of current power andWh, reset button.
ST 28 Solar Module polycrystallineST 28 Solar Module amorphous
Alternatively addidionalsolar module for"ST 14 moduleFrame". Quickchange holder.Power:Polycrystalline ca. 10 WAmorphous ca. 5 W.
ST 30Fuse Box
Fuse box with 4-pole FI-circuit breaker, CEE plugand 1.5 m feed cable withCEE plug.400 V / 50 Hz.
ST 20 DCDC Load
Panel 450 W halogen lamp,with switch, 12 V.
ST 20 RWSet of electrical loads
Four variable resistors:15 Ohm / 5,5A170 Ohm / 1,7A325 Ohm / 1,2A15,8 K.Ohm / 0.17A
IKSIKSSOLARTRAINERProfi
ST 97Basic PhotovoltaicLaboratory
Detailed experimentalinstructions on 12 themes,with solutions. Available inGermanEnglishSpanishFrench
ST 98Instruction Manual
Instructions for allcomponents.Available inGermanEnglishSpanishFrench
Technical changes reserved 2012-01
Reseller
IKS Photovoltaik GmbH
Tel. +49 561 / 9538050Fax + 49 561 / 9538051
Training systems
Measurement engineering
Special developments
An der Kurhessenhalle 16 b34134 Kassel / Germany IKS
Photovoltaik
ST 95Transformer
For the adaption of ST 02and ST 14 in 115 V-gridss. Inclusive outlet strip230 V.Transormer 115 V AC to230 VAC / 500 W.
ST 96Laboratory Table
Laboratory table , lockable wheels.Serves as a support for "ST 99 take-upframe", incl. fastening screws.Tabletop 1.25 x 0.62 m, height 0.74 m
ST 99 10 panelsHolding Frame
Take-up frame for 10instruction panels.
ST 99 15 panelsHolding Frame
Take-up frame for 15instruction panels.
One device - double benefit: Innovative PV measurement equipment foruse at the training system and at real PV plants
PV vocational education and training
Double benefit
The particular feature: The newly into the PVtraining system integrated Photovol ta icmeasurement equipment can be used afterwardsfor measurments and tests at real photovoltaicinstallations. A system withy double benefit.Because as always before we have focused on ahigh practical relevance when selecting thecomponents.
However, this also means that this subject has to bean integral part of the vocational education andtraining in the field of photovoltaic. A development,that was taken up with our latest product innovation.The well-known PV training system SolartrainerProfi was expanded with an measurementequipment, consisting of an innovative multifunctioninstrument, remote datalogger with radiotransmission, transducer clamps and an ISETSensor irradiation sensor with dimmable halogenspot for setting of irradiation values, as well aspractice-oriented didactic materials.
The PV training system Solartrainer Profi forvocational education and training wasexpanded with an innovative Photovoltaicmeasurement equipment
The background: Today PV plants are working veryreliable. Nevertheless they often generate only apart of the maximum possible power. The causesare multible and it is not rare that they can be tracedback before the period of the actual installation.Because even on the way to the installation sitemicro cracks can arise because of incorrect storageor as a result of incautious transport. The microcracks cannot be seen with the naked eye, howeverthe consequences have far reaching implications:If water has penetrated or soldered bonds wereinterrupted the efficiency of solar modules can benoticeable reduced. The financial losses for privateoperators as well as investors in large solar systemsmay be substancial. In practice the possibility ofmonitoring the characteristic curves of single solarmodules, strings and the test of completephotovoltaic installations becomes more and moreimportant.
SOLARTRAINERProfi
IKSPhotovoltaik
IKS
new
ST 97 Versuchssanleitung
SOLARTRAINERProfi
Grundlagen- und Praxislabor Photovoltaikmit dem PV-Testgeräteset
IKSPhotovoltaik
SOLARTRAINERProfi
IKSPhotovoltaik
IKS
Scope of delivery
� Multifunction instrument with tool pocket
Measuring range performance analysis:Voltage DC: 15,0 V - 999,9 VVoltage AC: 50,0 V - 265,0 VCurrent DC (über Stromzange): 50 mA - 1100 ACurrent AC (über Stromzange): 10 mA - 1200 APower DC: 1 W - 999,9 kWPower AC: 1 W - 999,9 kW
Measuring range I-U curve measurement:Voltage DC: 5,0 V - 999,9 VCurrent DC: 0,1 A - 10,0 APower DC: 50 W - 999,9 W / 1.000 kW - 9.999 kWIrradiance (with ST 36) 1,0 mV - 100,0 mV
PV measurement equipment
IKS Photovoltaik GmbH
Tel. 0561 / 9538050Fax 0561 / 9538051
Training systems
Measurement engineering
Special developments
An der Kurhessenhalle 16 b34134 Kassel / Germany IKS
Photovoltaik
Experiments
�
�
�
�
�
�
�
�
�
I-U curve recording of different solar modules
I-U curve recording of different solar modulesat different irridiation intensities
Temperature influence on the I-U curve ofdifferent solar modules
I-U curve recording of a series connection ofsolar modules
I-U curve recording of a parallel connection ofsolar modules
Shading of a series connection of solar moduleswithout bypass diode, I-U curve recording
Shading of a series connection of solar moduleswith bypass diode, I-U curve recording
Photovoltaic plant mains parallel operation,measuring of the inverter efficiency
Test of a photovoltaic plant mains parallel operation,measuring also the irradiation and temperature.Measuring of the inverter efficiency, solar modulesefficiency and the overall efficiency (performanceratio) and issue of a test report
�
�
�
�
�
�
�
Test of a photovoltaic plant mains parallel operation.Simulation of system failures:PV power too low / irradiation sensor failure /Irradiation value too low for evaluation
I-U curve recording and evaluation of a solar module(solar module simulated) also measuring the irradiationand temperature.Detection of underperformance
I-U curve recording and evaluation of a string(solar module simulated) also measuring the irradiationand temperature.Detection of underperformance
I-U curve recording and evaluation of a solar module(solar module outdoor) also measuring the irradiationand temperature and considering the position of the sun.Detection of underperformance
Rapid test on solar modules and strings with and withoutmeasuring the irradiation and temperature
Measuring the internal resistance of a solar module
Reading out and processing of the data with a PC
�
�
�
�
�
�
�
�
Remote datalogger with radiotranmission for irradianceand temperatureTransd. clamp DC 10 A /100 ATransd. clamp AC 5 A / 100 ATraining panelST 36 Solar radiation sensor(sensor removable)Module temperature sensorand ambient temperaturesensor -20 bis 100 °CMeasuring cables and adapter plugsData transfer sofware and evaluation softwareExperimental instructions
Subject to technical modifications. Stand: June 2012
Reseller
Technikerschule Butzbach„Solartrainer Profi has been in use for 15 years completely error-free and without repairs”
SOLARTRAINERProfi
IKSPhotovoltaik
IKS
Handwerkskammer Münster
„
Already the prototype won over -Solartrainer Profi in successful operation since 1997”
Landesstelle Hessen für gewerbliche
Berufsförderung in Entwicklungsländern„Solartrainer Prof for multiplier training”
Bildungsinstitut Pscherer“Fit for the job: basic and continuing vocational
training with the Solartrainer Profi”
BZ Bildungszentrum Kassel„Since 1997 more than 500 participants were trained with the Solartrainer Profi”“
University of NairobiInstitute of Nuclear Science and Technology
Some user report on practical experiences:
Photovoltaic-experimental kitfor teaching at schools
The available experimental materials allow thecarrying out of all basic experiments in the field ofphotovoltaics.Because the experiments are built up modularly theadaption to the actual teaching is possibleaccording to the requirement.
The materials are arranged clearly and opticallyattractive in a specific yellow suitcase. Everything isalways completely at hand, extra material is notnecessary.The experiments can be built up and removed fast.The pupils are able to carry out the experiments bythemselves with the help of the easilyunderstandable experimentation instruction.
physics.The teacher gets further information to do theexercises and to understand the
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
Series connection of solar cells / differentshadowing conditions
With extension kit - m
Measuring of the irradiance of different lightsourcesSolar cell as an energy converter
Solar cell as an energy converter and diodefunction
Open circuit voltage of a solar cell at differentshadowing conditions
Short circuit current of a solar cell at differentshadowing conditions
Open circuit voltage and short circuit current of asolar cell at different irradiance
Short circuit current of a solar cell dependingon angle of incidence of the light
Parallel connection of solar cells / differentshadowing conditions
Characteristic curve of a solar cell (I/U) / differentirradiance
Characteristic curve of a solar cell (U/P), MPP,figure out of the efficiency
Simulation: Short circuit current of a solar celldepending on position of the sun(sunrise to sunset)
Charging a GoldCap / accumulator with solarcellsDischarging a GoldCap / accumulator withelectric motor and light bulb
Building up of a stand alone operation net
Characteristic curve of a solar cell (I/U) /different irradiance
Demonstration of an inverter (sinwave /rectangular)
Charging a GoldCap / accumulator with solarcells, discharging a GoldCap / accumulator withelectric motor and light bulb
easurement with PC:
With the set of equipment supplied,the following experiments are possible:
IKSPhotovoltaik
IKS
Development supported financially bythe German Federal Ministry foreducation, science, research andtechnology. Identification-number0329841C
juniorSOLARTRAINER
Picture is showing optional extra
�
�
�
�
�
�
�
�
�
�
�
�
�
Set of equipment supplied: Optional extension kit:
Specific yellow suitcase with shaped part made offoam plastic
Basic board with frame to put the experimentalboxes und multimeters
Low voltage (12 V ) halogen lamp
Power supply with dimmer switch, power cable(mains fed, input 230 V AC 50 Hz, output 12 V AC)Solar module with 4 single cells and angleadjustment
2 multimeters with 2 mm connectors
Sensor box for measuring irradiance
Load box with electric motor and light bulb
Storage box with NC accumulator and GoldCapand blocking diode
Measuring box with variable resistor
Connecting cords, high flexible, contacts brass /hard copper gold plated
Experimental instruction / documentation forteacher
PC measuring boxInverter boxInterface cableSoftware (runningunder WINDOWS)
IKSPhotovoltaik
IKS
Reseller
Subjekt to alteration. Pictures additionally are showing partiallyoptional extra. State: 2012-01
Dimmable halogen light (low voltage 12 V)which can be moved around the solarmodule in a semicircle, disconnectablefor experiments with sun light
Solar module with 4 single solarcells and angle adjustment.Integrated power supply inthe basic housing
Basic board with frameto put the experimentalboxes und multimeters
IKS Photovoltaik GmbH
Phone +49 (0) 561 / 9538050Fax +49 (0) 561 / 9538051
Training systems
Measurement engineering
Special developments
An der Kurhessenhalle 16 b34134 Kassel / Germany IKS
Photovoltaik
juniorSOLARTRAINER
With the set of equipment supplied,the following experiments are possible:
IKSPhotovoltaik
IKS
�
�
�
�
�
�
�
�
�
�
�
�
�
Measuring of the wind force in the vicinity ofthe school
Measuring of the wind force of the windmachine dending on the adjustment of thecontrol knob
Power output of the generator depending onthe shape of the wing (even / curved)
Power output of the generator depending onthe number of wings (2, 3 , 4)
Power output of the generator depending onthe position (angle) of the wing
U/) atconstant speed
U/).Measuring the resistance- and buoyancy rotorat constant wind force
Power output of the generator depending onthe wind force
Charge of an akku/Gold Cap with thegenerator
Discharge an akku/Gold Cap with differentloads
U/) atconstant speed
Power output of the savonius rotor operatingwith and without aperture
With extension kit savonius rotor
Characteristic curve of a generator (
Characteristic curve of a generator (
Build up of a stand alone operation net
Characteristic curve of a savonius rotor(
:
Windenergy-experimental kit forteaching at schools
The available experimental materials allow thecarrying out of all basic experiments in the field ofwindenergy.Because the experiments are built up modularly theadaption to the actual teaching is possible accor-ding to the requirement.
The materials are arranged clearly and opticallyattractive in a specific with suitcase. Everything isalways completely at hand, extra material is notnecessary.The experiments can be built up and removed fast.The pupils are able to carry out the experiments bythemselves with the help of the easily under-standable experimentation instruction.
physics.
The teachergets further information to do the exercises und tounderstand the
WINDTRAINERjunior
Picture is showing optional extra
Reseller
�
�
�
�
�
�
�
�
�
�
�
�
�
Wind machine with controllable power supply
Wind power plant with axial rotor,generator without gear, with tacho generator,hub for mounting 2, 3, and 4 wings, angle ofthe wings adjustable
4 wings even, 4 wings curved
Protection cover, wind shield, tool
Anemometer
Savonius-Rotor
Set of equipment supplied: Optional extension kit:
Specific white suitcase with shaped part madeof foam plastic
Basic board with frame to put the experimentalboxes und multimeters
2 multimeters with 2 mm connectors
Load box with electric motor and light bulb
Storage box with NC accumulator andGoldCap and blocking diode
Measuring box with variable resistor
Experimental instruction / documentation forTeacher
Subjekt to alteration. Pictures partially with optional extra.State: 2012-01
IKSPhotovoltaik
IKS
Accessories and tool
Controllable wind machine (low voltage)
Wind power plant withprotection cover anddegree scale
Basic board with frame to put theexperimental boxes und multimeters
IKS Photovoltaik GmbH
Phone +49 (0) 561 / 9538050Fax +49 (0) 561 / 9538051
Training systems
Measurement engineering
Special developments
An der Kurhessenhalle 16 b34134 Kassel / Germany IKS
Photovoltaik
WINDTRAINERjunior
Anemometer
Hydrogen-/ Fuel Cell-experimental kit forteaching at schools
ydrogen-/ fuel celltechnology
The available experimental materials allow the carrying out ofall basic experiments in the field of h
.Because the experiments are built up modularly the adap-tion to the actual teaching is possible according to therequirement.
The materials are arranged clearly and opticallyattractive in a specific red suitcase. Everything isalways completely at hand, extra material is notnecessary.The experiments can be built up and removed fast.The pupils are able to carry out the experiments bythemselves with the help of the easilyunderstandable experimentation instruction.
physics.The teacher gets further information to do theexercises and to understand the
�
�
�
�
�
�
�
�
�
�
Measuring of the volume ratio of the generatedgases
Measuring of the generated volumes of thegases per unit of time depending on thecurrent
Determination of the power effiency and theFaraday efficiency of the elektrolyser
Determination of the U/I- characteristic of theelektrolyser
Determination of the power effiency and theFaraday efficiency of the fuel cell
Determination of the U/I- characteristic of thefuel cell
In combination with the Solartrainer junior:
Operation of the elektrolyser with solar cells
In combination with the Windtrainer junior:
Operation of the elektrolyser with windenergy
In combination with the Solartrainer junior
and the Windtrainer junior:
Operation of the elektrolyser with solar cells
and windenergy as a hybrid system
Building up of a stand alone operation net
IKSPhotovoltaik
IKS
With the set of equipment supplied,the following experiments are possible:
juniorH -TRAINER
Reseller
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
Elektrolyser
Power supply
Current control box
Gas storage
Fuel cell
Connecting hoses/caps
Destilled water
Syringe
Set of equipment supplied:
Specific red suitcase with shaped part made offoam plastic
Basic board with frame to put the experimentalboxes und multimeters
2 multimeters with 2 mm connectors
Load box with electric motor and light bulb
Measuring box with variable resistor
Connecting cords, highly flexible, contactsbrass/hard copper gold plated
Experimental instruction / documentation forTeacher
IKSPhotovoltaik
IKS
Subjekt to alteration. State: 2012-01
Elektrolyser, gas storage and fuel cell
Power supply andaccessory
Basic bord and frame to put theexperimentation modules and multimeter
IKS Photovoltaik GmbH
Phone +49 (0) 561 / 9538050Fax +49 (0) 561 / 9538051
Training systems
Measurement engineering
Special developments
An der Kurhessenhalle 16 b34134 Kassel / Germany IKS
Photovoltaik
juniorH -TRAINER
IKSPhotovoltaik
IKS
Measurement equipment
Illuminance level
With the lux meter living areas and workplaces canbe inspected of adequate and evenly distributedilluminance level - which is prerequisite for a nonfatigue seeing.
The measurement devices are arranged clearly andoptically attractive in a specific green suitcase.Everything is always completely at hand, extramaterial is not necessary.
With the high-class multi measuring device and amultible sensor the CO -concentration, relative air
humidity, indoor temperature and the absolute airpressure can be measured contemporaneously.The values are displayed on a big LCD-display andcan be logged optionally.With the relative air humidity and the indoor tem-perature it is possible to determine the dew pointtemperature tabularly.
With the infrared thermometer it is possible tomeasure surface temperatures contactless.The wall temperature can be inspected of criticaldew point temperatures (mildew potential).
Room air quality
Surface temperature
2
With the set of equipment supplied, the followingmeasurements are possible:
For energy consultants, caretakers, consultingengineers and environment issues managers theideal tool for building diagnostics and room airanalyses.Furthermore there can be made analyses in the fieldof water consumption, lighting and energyconsumption of electrical appliances.
This way it is possible to detect deficiencies andwasteful illumination can be avoided.
With the flow rate meter the water consumption atevery spigot can be determined.
With the energy meter the energy consumption ofelectrical appliances can be determined as well asthe energy costs.
Longitudes, areas and volumes can be measuredcomfortably and contactlessly with the electronicdistance meter.
Water consumption
Energy consumption of electrical appliances
Room dimensions
ProfiEnergie Check
IKSPhotovoltaik
IKS
Reseller
Subjekt to alteration. State: 2012-01
IKS Photovoltaik GmbH
Phone +49 (0) 561 / 9538050Fax +49 (0) 561 / 9538051
Training systems
Measurement engineering
Special developments
An der Kurhessenhalle 16 b34134 Kassel / Germany IKS
Photovoltaik
Profi
1 Luxmeter digitalEffective range 0 - 50.000 Lux,value-hold-function, sensorexternal with spiral cable.Metering precision +/- 5% + 2digits
1 Energy cost metersdigitalMeasuring of energy, power(Effective, apparent and idlepower), voltage, current,power factor, frequency,measuring time 24 h, 1-7 or 1-30days, costs, min. / max. values,cost prognosis and more features.Max. 3.680 W.
1 Flow rate meterEffective range 1 to 25 l/min,actual value can be read directlyon the scale
Content
1 Infrared digitalthermometerContactless measuring with twopoint laser targeting, display ofmeasuring spot size, effectiverange -30 ...+400 C°, emissionfactor adjustable 0,2 ... 1,00,lighted display, value hold function
1 Electronic distancemeter digitalEffective range 0,6 ... 20 m, withlaser pointer, measuring oflongitudes, aereas and volumes,memory, adding up function.Metering precision +/- 0,5%
1 Multi measuring device
1 Set of short instructions
With multible sensor (IAQ sensor)for measuring of CO - concen-
tration 0 .. + 10,000 ppm,temperature 0 .. + 50° C,relative air humidity 0 .. + 100 %,absolute air pressure+ 600 .. 1.150 hPa.Big digital LCD display.With data logger.Set up of up to 99 measuringocalities
1 Power supply
1 USB interface cable
1 Software
2
Energie Check
Measurement equipment
IKSPhotovoltaik
IKSEnergie Check
Indoor and outdoor temperatures
With the two digital temperature meters the indoorand outdoor temperatures can be measured just asthe min.And max. Values.
The measurement devices are arranged clearly andoptically attractive in a specific green suitcase.Everything is always completely at hand, extramaterial is not necessary.
With the two digital temperature-humidity-meters therelative air humidity and the air temperature can bemeasured.The measured values are displayed on a LCD-display, it is also possible to log the datas.With the relative air humidity and the air temperatureit is possible to determine the dew point temperature.The data can be read out by the RS-232 -interfacewith the enclosed software.
With the digital precision temperature meter it ispossible to measure surface temperatures, waterand air temperatures.The wall temperature can be inspected of criticaldew point temperatures (mildew potential).
Room air quality
Surface temperature
With the set of equipment supplied, the followingmeasurements are possible:
For projects at schools the ideal measurementequipment to deal with energy-saving, room-aircondition, water consumption, room lighting andenergy consumption of electrical appliances.
With the two analog temperature meters the airtemperature and the min. and max. values can bemeasured.
With the lux meter class-rooms and laboratoryareas can be inspected of adequate and evenlydistributed illuminance level - which is prerequisitefor a non fatigue seeing.This way it is possible to detect deficiencies andwasteful illumination can be avoided.
With the flow rate meter the water consumption atevery spigot can be determined.
With the energy meter the energy consumption ofelectrical appliances can be determined as well asthe energy costs.
Illuminance level
Water consumption
Energy consumption of electrical appliances
junior
IKSPhotovoltaik
IKSEnergie Check
Reseller
Subjekt to alteration. State: 2012-01
IKS Photovoltaik GmbH
Phone +49 (0) 561 / 9538050Fax +49 (0) 561 / 9538051
Training systems
Measurement engineering
Special developments
An der Kurhessenhalle 16 b34134 Kassel / Germany IKS
Photovoltaik
junior
2 Enery cost meters digitalMeasuring of energy, power(Effective power), voltage,measuring duration, duty cycle,costs, min. / max. values, costprognosis and more features
1 Lux meter digitalEffective range 0 - 50,000 Lux,value-hold-function, sensorexternal with spiral cable.Metering precision +/- 5% + 2digits
1 Precision digitalthermometerExternal sensor for measuring ofsurface, water and air temperatu-res.Effective range -199.9 ..+199.9 C°,Resolution 0.1° CPrecision 0...100° C: 0.1°C +/- 1digit
1 Flow rate meterEffective range 1 to 25 l/min,actual value can be read offdirectly on the scale
Content
2 Temperature humiditymeters digitalEffective range temperatur:0 .. + 59.9° C,Metering precision +/- 0.5 °CEffective range relative airhumidity: 1 .. 99 %Metering precision +/- 3%Time (DCF-77 signal)Min.-/ Max.- valuesPreset of alarm values possibleAverage valuesDew point temperatureBig digital-LCD-display,Data logger, up to 3,000 values,memory, time interval selectableRS 232-interfaceFoot to put up2 Interface cablesSoftware to read out, data exportand processing with other soft-ware possible
2 Indoor temperaturemeters analog
1 Set of short forminstructions
Effective range -35 ...+50° CMin- / Max. - values, reset
2 Indoor-/ outdoor tempe-rature meters digitalExternal sensor for measuring theoutdoor temperature,Cable length 3 mEffective range indoor temp.-10 ...+60° CEffective range outdoor temp.-50 ...+70° CMin- / Max. - valuesBig digital-LCD-display
Solar radiation sensor -high-quality measurement technology for the mass market
ISET Sensor
The new
Technical features of the
Photovoltaic plant system operators want tohave simple, quick and reliable informationabout the function of their PV-plant.Thermoelectric radiation sensors cannotcompared easily with a real PV-generatorwith respect to the "energy yield" becauseof their different spectral sensitiveness aswell as their different reflection- and tem-perature characteristics.In addition you have the relatively highacquisition cost.In contrast to this, the radiation sensors ofthe lower price category do not fulfill thelong-term accuracy requirements and mayfind no acceptance because of their "low-cost equipment ”, in particular in the field ofbuildings.The solar cell sensoreliminates these deficits. It fits well thephysical characteristics of the solargenerator. The simple and compact butnevertheless precise construct ionpredestine it for use
With the new housing design it gains thenecessary acceptance in the technicalservices for facilities as well as in thegeneral field of architecture.
The solar radiation is converted into aproportional current by an exact definedsolar cell . Via a specific shunt resistancewhich is coupled thermicall to the compactaluminum housing, the measured voltage isdetermined.The almost identical geometrical construc-tion of the test cell, comparable with PVmodules, as well as the specifically formedhousing with possibilities of outside tem-perature link-up and high weatherresistance assure reproducible results ofmeasurement.A Pt 1000 - temperature sensor registersthe cell temperature over a two-wire dataline with high measuring accuracy.The calibration of every
with a reference element constructed in an identical fashion an accreditedtest laboratory in W/m² and is documentedon a quality assurance calibrating certificate.
ISET
ISET
ISET
ISET Sensor
Sensor
Sensor
Sensor
in the field of buildingmeasurement technology.
is ar-chieved -
by
-
Spectral sensitivity of different sensors underAM 1,5 (normalized).
Further there are the same physical characteristics regardingtemperature, reflection and degradation.
With the for each photovoltaic technology thesuitable radiation sensor can be delivered.
ISET
ISET
Sensor
Sensor
It is clearly visible and derivable that for the energetical ratingand monitoring of a PV-plant should only be used the sametechnology of the sensor and the PV-plant because of thedifferent spectral sensitivity of the different technologies.
IKSPhotovoltaik
IKSISET Sensor
The relative measurement uncertainty is < ±4% (cryst.mat.) /< ±5% (am. mat.) The measurement uncertainty refers to aconfidence level of 1-alpha =95%.
Pt 1000, laminated or bonded centrally under the celll
-25° to + 80° C
Temperature sensor
Operating temperature range
* other versions according to customer preference (minimum quantity)
Technical data
Housing
Connecting cable
Available solar cell sensors
Measuring voltage
Calibration
- Aluminum, powder coating in facadequality, color is silvery grey *
- Mounting with two nuts M 5 backside- Housing pressure balance by means ofa special membrane.
AWG 26, shielded, black, length 3m *Plug connected
- monocrystalline- polycrystalline- amorphousEmbedded under clear glass hardenedthermiclly or embedded like solar module
- about 100 mV (cal.val.) /1000 W/m²,25°C
- Specific shunt resistance coupledthermiclly to the case.
The calibration of everya reference element (quality
gradeA, constructed in an identical fashion)from an accredited test laborator in W/m²by I / Kassel.A calibrating printout similar to EN DIN17025 documents the product specificparameters.
ISET
ISET
Sensor
Sensor is
achieved by
yWES
Reseller
Monitoringsystem
Monitoring concept
Using the in a onitoringconcept the received radiation powermeasured on the PV generator level iscompared with the output (AC) generated bythe PV system.The comparison quotient represents afunctional and quality parameter for the PV-plant in simplest way.By the implemented evaluation logic, solarmodule manufacturers, traders and evenelectricians receive via the cumulatedenergy output an insight into a simplified"course of life documentation" of theirproducts. In this way, questions about a"guaranteed” energy output are discussedmore reasonably, the energy output can beprovable.
ISET Sensor m
the
PV-Generator Inverter Main
Consumption loadSENSOL - SensorÒ
P -MeterAC
Digital analysis device
=~
¾1280 W
IKSPhotovoltaik
IKS
Subject to alteration. State: 2012-01
ISET Sensor
ISET Sensor
�
IKS Photovoltaik GmbH
Phone +49 (0) 561 / 9538050Fax +49 (0) 561 / 9538051
Training systems
Measurement engineering
Special developments
An der Kurhessenhalle 16 b34134 Kassel / Germany IKS
Photovoltaik
IKSPhotovoltaik
IKS
Solar radiation meterStandard
Technical Specification
Max. Variation P : < 3 % ± 1 digit in range 50 … 1.000 W/m²
(AM 1,5 / normal axis radiation (*2), T = 0 … +50 °C)
Max. Variation T: < 3 °C ± 1 digit in range -25 … +75 °C, optional < 1 °C ± 1 digit
Power requirement (active Mode): 4 mW
Integrated solar module nominal power 180 mW *1Ambient temperature measurement range: -20 … +50 °C (Ambient tempratur)Max. ambient humidity: 90 %Dimensions (without mounting): 130 x 90 x 30 mm orWeight (without mounting): 170 gCertification CE / EN50081, EN50082Calibration according to: IEC904/3, Calibration certificate on requestWarrenty 2 years
(*1) At standard conditions Ptot = 1.000 W/m², solar spectrum AM 1,5 at T = 25 °C(*2) Certified by PI Photovoltaik-Institut Berlin AG
tot
Measuring range / Resolution
IKS Photovoltaik GmbH
Phone +49 (0) 561 / 9538050Fax +49 (0) 561 / 9538051
Training systems
Measurement engineering
Special developments
An der Kurhessenhalle 16 b34134 Kassel / Germany IKS
Photovoltaik
0 ... 1.000
Subject to alteration, state 2012-01
Child oriented readout system forvisualization of energy yields fromphotovoltaic plants
Photovoltaic plants as shining examples onthe roofs of kindergartens and schools
Visualization not child oriented so far
New concept of a visualization
The possibility to convert sunlight with solar cellsdirectly into electric power, makes the photovoltaicto one of the popular renewable energies.It is for this reason that photovoltaic plants areinstalled enhanced on kindergartens and schools.Apart from the aspirated example function the kidsshould be most familiarized with renewableenergies.
For the visualization of the energy yields of photo-voltaic plants typically the “standard solution” isused: A large sized digital display to show the actualpower and the total electric power fed to the mains.It has turned out however that most of the kidsquickly loose interest in the display also because itis not really plain.
That is why the University of Applied sciencesMünster has greated a new concept of visualizationwithin the scope of a disatation.The preproduction model was developed by thecompany IKS Photovoltaik as a licence partner.
IKSPhotovoltaik
IKS
The actual electric power
The monthly fed in energyis displayed
Digital displays
is displayed analoguely bymeans of 24 symbolici n c a n d e s c e n t l a m p s(inside LED), because kidsknow electricity above allfrom incandescent lamps ineveryday life.The higher the actual outputof the photovoltaic plant isthe more lamps are inoperation.
analoguely byred balls, which weretransported by the sunwheel into the catch tank.The number of bal lstransported depends on theenergy fed into the mains.Atthe end of the month theballs are filled back into theabove storage tank and thedigital display for themonthly energy yield is setto zero.
for theactual power, the monthlyand the total energy yieldare there additionally.
The system is preferably forwallmounting in publicareas of entryways.
Awarded with the ymposium of photovoltaicsolarenergy 2005 in Staffelstein / Germany.
„Special prize for the most interesting exhibit“ by the conference jury of the 20th s
VisiKid
Currently only availablewithin Germany
Reseller
Technical specifications:
�
�
�
�
�
�
�
�
�
�Dimensions: 1036 x 836 x 146 mm
Weight: 12 kg
Power supply 230 V / 50 Hz / 12 V DC
Digitale LCD display-Actual power-Monthly energy yield (with reset function)-Total energy yield
Analogue display of the actual power by 24 symbolic“incandescent lamps” (LED inside)
Analogue display of the monthly energy yield by redballs (360 pieces), which are transported by thesun wheel from the storage tank into the catch tankdepending on the energy fed into the mains
Removable catch tank, secured by lock
Low power requirement (max. 6.5 W)
Inputs:1x impulse for meterFor So-interface according to DIN EN 62053-31Not suited for meters with impulse packets output
According to the photovoltaic plant size freelyprogrammable
�
�
Advertising space for label ca. B 280 x H 170 mm
Only for indoor use
IKSPhotovoltaik
IKS
Subjekt to alteration. State: 2012-01
IKS Photovoltaik GmbH
Phone +49 (0) 561 / 9538050Fax +49 (0) 561 / 9538051
Training systems
Measurement engineering
Special developments
An der Kurhessenhalle 16 b34134 Kassel / Germany IKS
Photovoltaik
VisiKid
Currently only available for delivery to Germany
Vertriebspartner / Reseller / Socios distribudores