9
1 16 October 2019 1 Standard Penetration Test (SPT) ﺍﺧﺘﺒﺎﺭ ﺍﻻﺧﺘﺮﺍﻕ ﺍﻟﻘﻴﺎﺳﻰ ﺍﻟﻣﻁﺭﻗﺔ ﺃﻭ ﺍﻟﻣﻧﺩﺍﻟﻪ16 October 2019 2 Standard Penetration Test (SPT) 1- Standard Penetration Test (SPT): - 140 lb hammer is dropped over a 1.5 ft long standard spoon. - The hammer drop height is 2.5 ft. - The spoon is driven 1.5 ft in three stages, each stage is 6 inch long. - SPT (N) value = Number of hammer drops that will drive the standard spoon 1 ft long into the soil, if N > 50 means refusal. - The first reading is neglected (seating), the 2 nd and 3 rd readings are summed up to give N. 1 2

ﻭﺃ ﺔﻗﺭﻁﻣﻟﺍ ﻪﻟﺍﺩﻧﻣﻟﺍ · Standard Penetration Test (SPT) 1-Standard Penetration Test (SPT):-140 lb hammer is dropped over a 1.5 ft long standard spoon.-The

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ﻭﺃ ﺔﻗﺭﻁﻣﻟﺍ ﻪﻟﺍﺩﻧﻣﻟﺍ · Standard Penetration Test (SPT) 1-Standard Penetration Test (SPT):-140 lb hammer is dropped over a 1.5 ft long standard spoon.-The

1

16 October 2019 1

Standard Penetration Test (SPT)اختبار االختراق القياسى

المطرقة أو المنداله

16 October 2019 2

Standard Penetration Test (SPT)

1- Standard Penetration Test (SPT):

- 140 lb hammer is dropped over a 1.5 ft long standard spoon.

- The hammer drop height is 2.5 ft.

- The spoon is driven 1.5 ft in three stages, each stage is 6 inch long.

- SPT (N) value = Number of hammer drops that will drive the standard spoon 1 ft long into the soil, if N > 50 means refusal.

- The first reading is neglected (seating), the 2nd

and 3rd readings are summed up to give N.

1

2

Page 2: ﻭﺃ ﺔﻗﺭﻁﻣﻟﺍ ﻪﻟﺍﺩﻧﻣﻟﺍ · Standard Penetration Test (SPT) 1-Standard Penetration Test (SPT):-140 lb hammer is dropped over a 1.5 ft long standard spoon.-The

2

16 October 2019 3

اختبار االختراق القياسى):االختبار يجرى أثناء أخذ الجسة(طريقة إجراء االختبار

من ارتفاع ) كجم 62.5(رطل 140يتم إسقاط مطرقة وزنها - 1.50على ملعقة قياسية ارتفاعها ) سم 75(قدم 2.50مقداره

).سم 45(قدم بوصه 6يتم دق تلك المعلقة على ثالثة مراحل طول كل مرحلة -

).سم 15(.(Seating)سم األولى وتسمى 15يتم إهمال قراءة الـ -.(N)يتم جمع القرائتين الثانية والثالثة ومجموعهم يسمى -ة عدد الدقات التى تتسبب فى اختراق الملعق= N (SPT)قراءة -

.سم 30القياسية للتربة لمسافة دقة تسمى امتناع ويمكن فى 50أكبر من (N)إذا كانت القراءة -

.50> هذه الحالة كتابة الرقم الحقيقى أو كتابة

16 October 2019 4

Standard Penetration Test (SPT)

3

4

Page 3: ﻭﺃ ﺔﻗﺭﻁﻣﻟﺍ ﻪﻟﺍﺩﻧﻣﻟﺍ · Standard Penetration Test (SPT) 1-Standard Penetration Test (SPT):-140 lb hammer is dropped over a 1.5 ft long standard spoon.-The

3

16 October 2019 5

Standard SPT Split spoon

الملعقة القياسة الختبار االختراق القياسى

16 October 2019 6

5

6

Page 4: ﻭﺃ ﺔﻗﺭﻁﻣﻟﺍ ﻪﻟﺍﺩﻧﻣﻟﺍ · Standard Penetration Test (SPT) 1-Standard Penetration Test (SPT):-140 lb hammer is dropped over a 1.5 ft long standard spoon.-The

4

16 October 2019 7

SPT spoon

16 October 2019 8

Standard Penetration Test

7

8

Page 5: ﻭﺃ ﺔﻗﺭﻁﻣﻟﺍ ﻪﻟﺍﺩﻧﻣﻟﺍ · Standard Penetration Test (SPT) 1-Standard Penetration Test (SPT):-140 lb hammer is dropped over a 1.5 ft long standard spoon.-The

5

9Site Investigation, Tarek Nageeb16 October 2019 Site Investigation, Tarek b

9

N

DR = relative densityT = unit weight = friction angleeo = void ratioReliable

SAND

cu = undrained strengthT = unit weightUnreliable

CLAY

SPT RESULTS

16 October 2019 10

Relation between SPT (N) value and o for sand.

Relation between SPT (N) value and unconfined compressive strength of clay

9

10

Page 6: ﻭﺃ ﺔﻗﺭﻁﻣﻟﺍ ﻪﻟﺍﺩﻧﻣﻟﺍ · Standard Penetration Test (SPT) 1-Standard Penetration Test (SPT):-140 lb hammer is dropped over a 1.5 ft long standard spoon.-The

6

16 October 2019 11

Relation between SPT (N) value and o for sand.العالقة بين عدد الدقات القياسية وزاوية االحتكاك الداخلى والكثافة

النسبية للرمل

16 October 2019 12

SPT Vs. Bearing Capacityand Settlement in Sand

تحديد قدرة تحمل التربة والهبوط من اختبار االختراق القياسى

Evaluation of soil bearing capacity corrected blow count, Peck (1974).

11

12

Page 7: ﻭﺃ ﺔﻗﺭﻁﻣﻟﺍ ﻪﻟﺍﺩﻧﻣﻟﺍ · Standard Penetration Test (SPT) 1-Standard Penetration Test (SPT):-140 lb hammer is dropped over a 1.5 ft long standard spoon.-The

7

16 October 2019 13

SPT readings are corrected for:

1- Depth. تصحيح ألخذ تأثير العمق الذى يجرى عند االختبار

2- Presence of ground water table

أخذ تأثير وجود مياه جوفية على القراءة .

3- Borehole diameter. أخذ تأثير قطر الجسة

4- Driving energy. أخذ تأثير طاقة الدق

Corrections of SPT Readings

SPTتصحيحات قراءة

هتصحيح عمل األختبار تحت المياه الجوفي

مره وذلك 15اذا كانت اكبر من Nيجري تصحيح قيمة ال :يهفى حالة الرمل الرفيع والطمي بأستخدام المعادله اآلت

𝑁𝑚=15+12(𝑁−15) N>15

Nm=15 N<15

16 October 2019 Site Investigation, Tarek Nageeb 14

13

14

Page 8: ﻭﺃ ﺔﻗﺭﻁﻣﻟﺍ ﻪﻟﺍﺩﻧﻣﻟﺍ · Standard Penetration Test (SPT) 1-Standard Penetration Test (SPT):-140 lb hammer is dropped over a 1.5 ft long standard spoon.-The

8

تصحيح نتيجة أهمال وزن عمود التربة

16 October 2019 Site Investigation, Tarek Nageeb 15

الالفع التربه عمود لوزن نتيجة المقاسهN ال قيمة تصحيح يتماعلي

قيمة رببض - الخشنه – الرمليه للتربه وذلك , االختبار منسوب قيمة وتستنج ( CN )الجوفية مياه وجود نتيجة المصححةN ال

المعاملهذا يستخدم وال المبين للمنحني طبقا الجسه لقطر تبعا ثافهالك فيه تقل والذي السائب الرمل حالة فى التصحيحهذا

0.50عن النسبيه𝑁𝑚 𝐶𝑁∗𝑁m

,,, المصححه الدقات عددNm ,,, التصحيح معاملCn حيثNmالجوفية المياه نتيجة المصححة الدقاتعدد

16 October 2019 Site Investigation, Tarek Nageeb 16

15

16

Page 9: ﻭﺃ ﺔﻗﺭﻁﻣﻟﺍ ﻪﻟﺍﺩﻧﻣﻟﺍ · Standard Penetration Test (SPT) 1-Standard Penetration Test (SPT):-140 lb hammer is dropped over a 1.5 ft long standard spoon.-The

9

مميزات أختبار األختراق القياسيسهولة وبساطة المعدات و سهولة وامكانية التكرار لخطوات االختبار

امكانية استخراج عينات مقلقله لكل من التربه والصخر الضعيف

امكانية اجراؤها اعلى واسفل منسوب المياه الجوفيه

يجري االختبار داخل الجسه

بيه نظرا هذا االختبار ضروري فى حالة التربه الرمليه لتحديد كثافتها النس .لصعوبة الحصول على عينات غيرمقلقله منها

ليه نتائج هذا االختبار تعتبر مؤشر ألحتمال حدوث تسييل للتربه الرم السائبه المتواجده اسفل سطح المياه االرضيه اثناء الهزات االرضيه

16 October 2019 Site Investigation, Tarek Nageeb 17

17