15
Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. Some of the tests or test methods in this report may not in NVLAP accreditation scope and was noted. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. IES LM-79-08 MEASUREMENT AND TEST REPORT For ShenzhenBrilloopLightingCo.,Lt 6F,B6Building,JunfengIndustrialPark,YongheRoad,Fuyong,BaoanDistrict,Shenzhen City,GuangdongProvince,P.R.Chin Test Model: BLP-HBL230WE06 Report Type: Electrical and Photometric tests including: Luminous Flux, Power Factor, Chromaticity, Luminous Intensity Distribution, THD Test Engineer: Bill Xiong Hill Liu Report Number: R2DG170711052-10 Test Date: 2017-07-13 to 2017-07-14 Report Date: 2017-07-17 Reviewed By: Daniel Duan /EE Manager Test Facility: Test facility was located at No.69, Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China. Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone, Shenzhen, Guangdong, China. Tel: +86-755-33320018 Fax: +86-755-33320008 Accreditation: The NVLAP Lab Code is 200707-0.

IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the

device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance

Laboratories Corp. (Shenzhen). This report must not be used by the customer to claim product certification, approval, or

endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. Some of the tests or test methods in this report

may not in NVLAP accreditation scope and was noted.

This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above

version 7.0.

IES LM-79-08 MEASUREMENT AND TEST REPORT

For

ShenzhenBrilloopLightingCo.,Lt 6F,B6Building,JunfengIndustrialPark,YongheRoad,Fuyong,Bao’anDistrict,Shenzhen

City,GuangdongProvince,P.R.Chin

Test Model: BLP-HBL230WE06

Report Type: Electrical and Photometric tests including: Luminous Flux,

Power Factor, Chromaticity, Luminous Intensity

Distribution, THD

Test Engineer: Bill Xiong Hill Liu

Report Number: R2DG170711052-10

Test Date: 2017-07-13 to 2017-07-14

Report Date: 2017-07-17

Reviewed By: Daniel Duan /EE Manager

Test Facility: Test facility was located at No.69, Pulongcun, Puxinhu Industry

Area, Tangxia, Dongguan, Guangdong, China.

Prepared By:

Bay Area Compliance Laboratories Corp. (Shenzhen)

6/F., West Wing, Third Phase of Wanli Industrial Building,

Shihua Road, Futian Free Trade Zone,

Shenzhen, Guangdong, China.

Tel: +86-755-33320018

Fax: +86-755-33320008

Accreditation: The NVLAP Lab Code is 200707-0.

Page 2: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711052-10 Page 2 of 15

1. Product Description

General Information:

One sample was received on 2017-07-11.

Model Tested: BLP-HBL230WE06

Manufacturer: ShenzhenBrilloopLightingCo.,Lt

Brand Name: Brilloop

Product Designation: LED High Bay Light

Burning Time Before Test: 0hour(For New Products)

Driver Model: ELG-240-48A

Rated Values:

Rated Voltage/Frequency: 100-240 V AC 50/60Hz

Rated Power: 230 W

Nominal CCT: 4000K

Nominal Lumen Output: 34080Im

2. Standards Used

IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products

ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting

IES TM-30-15: IES Method for Evaluating Light Source Color Rendition (This method is not in NVLAP

accreditation scope)

3. Description of Test Equipment

Device Manufacture Model No Serial No Test Range Calibration

date

Calibration due

date

1.5m temperature

integrating sphere SENSING SPR-600 S09008 25~50°C 2017-03-09 2018-03-09

High-precision

rapid spectral

analysis system

EVERFINE HAAS-2000 M112048CA136

1125 380-780nm 2017-07-07 2018-07-07

Digital power

meter YOKOGAWA WT310 13398 N/A 2016-12-05 2017-12-05

Programmable

Precision DC

Power Supply

ITECH IT6154 0061 0417 6471

0010 19 0~32V 2017-03-03 2018-03-03

thermometer SENSING NA NA 25、50°C 2017-03-09 2018-03-09

Standard Light

Source SENSING NA LSD090808 N/A 2016-12-05 2017-12-05

Precision

frequency power

supply

ALL Power APW-105N 970613 220V±10%

50Hz 2017-03-03 2018-03-03

AC POWER

SUPPLY EVERFINE VPS1030 PWM 1012017

0-150V, 0-

300V 2017-03-03 2018-03-03

Digital CC&CV

DC Power Supply EVERFINE WY12010 1009009 30V/5A 2017-03-03 2018-03-03

Digital power

meter YOKOGAWA WT-210 91KB35700

15/30/60/150/30

0/600 V 2017-03-03 2018-03-03

full-field speed

goniophotometer EVERFINE GO-R5000

YG108492N101

20001

1600mm,3000

W/10A 2017-03-09 2018-03-09

Page 3: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711052-10 Page 3 of 15

Device Manufacture Model No Serial No Test Range Calibration

date

Calibration due

date

Wireless Remote

Sensor N/A 433MHz N/A

0°C~50°C;-

20°C~60°C 2017-03-20 2018-03-20

Standard Light

Source EVERFINE D908 1012003 N/A 2016-12-17 2017-12-17

Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI).

4. Test Method

Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.

Integrating Sphere System

The system includes AC power source, digital power meter, DC power supply, Spectroradiometer, and integrating sphere. The integrating sphere system is calibrated by standard spectrum light source before measurement.

4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the light output (luminous flux) measurements is U=2.1% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=32K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=2.1 (K=2) , at the 95% confidence level.

The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level.

Goniophotometer System

The goniophotometer system is calibrated by standard light source before measurement.

Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report. The vertical angle (γ) test intervals were set no more than 1 degree while data for 5 degree intervals is reported. The horizontal angle (C plane) test intervals were set no more than 22.5 degree.

The uncertainty of the luminous intensity is U=1.6% (K=2) , at the 95% confidence level.

Additional Test

The Additional Test item may not be covered by IESNA LM-79-2008. Additional test is THD, was measured by Digital Power Meter after stabilized at 25°C±1°C.Test voltage for THD test would be equal to rated voltage or, in case of a voltage range, maximum value of that range.

The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level.

Fidelity Index and Gamut Index Calculation

The Rf, Rg was calculated according to IES TM-30-15 by using calculation tools. The calculation was based on the

measured SPD from 380nm to 780nm with 1nm intervals. All the colors in this report is for reference only.

Page 4: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711052-10 Page 4 of 15

5. Test Result

[Integrating Sphere System]

Total operating time for integrating sphere test: 1.0 hour

Test orientation: Downward

Photometric and Electrical Measurement Result

Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor Luminous Flux(lm)

Efficacy (lm/W)

229.9 50 0.9899 224.4 0.9861 34080 151.86

Radiant Flux (W) CCT (K) Duv x y u' v'

103.4 4173 0.0000587 0.3731 0.3721 0.2221 0.4984

Color Rendering Index

Ra

81.9

R1 R2 R3 R4

80 88 93 81

R5 R6 R7 R8

80 82 86 65

R9 R10 R11 R12

6 70 80 58

R13 R14 R15

82 96 75

-20 0 20 40 60 80 100

Page 5: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711052-10 Page 5 of 15

Fidelity Index and Gamut Index

Fidelity Index Rf 81

Gamut Index Rg 96

Spectral Power Distribution Comparison

Plot of Rg versus Rf

0

0.2

0.4

0.6

0.8

1

1.2

1.4

1.6

1.8

380 430 480 530 580 630 680 730 780

SPD

(n

orm

aliz

ed

to

Y=1

00

)

l (nm)

Test source Reference source

60

70

80

90

100

110

120

130

140

50 60 70 80 90 100

Rg

Rf

Page 6: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711052-10 Page 6 of 15

Chroma Shift by Hue Rf by Hue

Color Vector Graphic

-20%

-15%

-10%

-5%

0%

5%

10%

15%

20%

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Hue Bin

50

55

60

65

70

75

80

85

90

95

100

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Hue Bin

Refenerce Illuminat Test Source

Page 7: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711052-10 Page 7 of 15

Color Fidelity by CES Sample

0 20 40 60 80 100

CES01

CES03

CES05

CES07

CES09

CES11

CES13

CES15

CES17

CES19

CES21

CES23

CES25

CES27

CES29

CES31

CES33

CES35

CES37

CES39

CES41

CES43

CES45

CES47

CES49

CES51

CES53

CES55

CES57

CES59

CES61

CES63

CES65

CES67

CES69

CES71

CES73

CES75

CES77

CES79

CES81

CES83

CES85

CES87

CES89

CES91

CES93

CES95

CES97

CES99

Fidelity Index, Rf

Co

lor

Eval

uat

ion

Sam

ple

Page 8: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711052-10 Page 8 of 15

Relative Spectral Power Distribution

nm mW nm mW nm mW nm mW nm mW

380 8.576E+00 421 3.646E+01 462 3.578E+02 503 2.924E+02 544 4.690E+02

381 8.555E+00 422 4.103E+01 463 3.441E+02 504 3.005E+02 545 4.722E+02

382 6.795E+00 423 4.568E+01 464 3.314E+02 505 3.089E+02 546 4.742E+02

383 7.428E+00 424 5.097E+01 465 3.179E+02 506 3.173E+02 547 4.766E+02

384 7.229E+00 425 5.696E+01 466 3.024E+02 507 3.250E+02 548 4.790E+02

385 6.684E+00 426 6.282E+01 467 2.861E+02 508 3.319E+02 549 4.814E+02

386 6.450E+00 427 7.125E+01 468 2.691E+02 509 3.391E+02 550 4.837E+02

387 5.398E+00 428 7.939E+01 469 2.501E+02 510 3.458E+02 551 4.862E+02

388 5.142E+00 429 8.989E+01 470 2.333E+02 511 3.528E+02 552 4.884E+02

389 5.549E+00 430 9.968E+01 471 2.160E+02 512 3.598E+02 553 4.919E+02

390 4.461E+00 431 1.113E+02 472 2.025E+02 513 3.653E+02 554 4.951E+02

391 4.632E+00 432 1.249E+02 473 1.897E+02 514 3.726E+02 555 4.972E+02

392 5.023E+00 433 1.395E+02 474 1.800E+02 515 3.781E+02 556 5.004E+02

393 4.889E+00 434 1.555E+02 475 1.714E+02 516 3.826E+02 557 5.041E+02

394 4.484E+00 435 1.745E+02 476 1.662E+02 517 3.875E+02 558 5.065E+02

395 4.434E+00 436 1.951E+02 477 1.628E+02 518 3.926E+02 559 5.099E+02

396 4.376E+00 437 2.192E+02 478 1.604E+02 519 3.969E+02 560 5.123E+02

397 5.027E+00 438 2.456E+02 479 1.599E+02 520 4.016E+02 561 5.147E+02

398 4.579E+00 439 2.765E+02 480 1.592E+02 521 4.055E+02 562 5.178E+02

399 4.923E+00 440 3.128E+02 481 1.601E+02 522 4.093E+02 563 5.211E+02

400 5.428E+00 441 3.531E+02 482 1.608E+02 523 4.127E+02 564 5.246E+02

401 5.377E+00 442 4.007E+02 483 1.624E+02 524 4.172E+02 565 5.266E+02

402 5.978E+00 443 4.516E+02 484 1.639E+02 525 4.206E+02 566 5.297E+02

403 5.982E+00 444 5.092E+02 485 1.665E+02 526 4.236E+02 567 5.330E+02

404 6.363E+00 445 5.676E+02 486 1.683E+02 527 4.264E+02 568 5.366E+02

405 7.053E+00 446 6.253E+02 487 1.713E+02 528 4.294E+02 569 5.381E+02

406 7.586E+00 447 6.794E+02 488 1.749E+02 529 4.330E+02 570 5.422E+02

407 8.197E+00 448 7.247E+02 489 1.801E+02 530 4.343E+02 571 5.444E+02

408 8.914E+00 449 7.560E+02 490 1.854E+02 531 4.374E+02 572 5.470E+02

409 9.879E+00 450 7.686E+02 491 1.912E+02 532 4.401E+02 573 5.500E+02

410 1.078E+01 451 7.643E+02 492 1.980E+02 533 4.424E+02 574 5.529E+02

411 1.172E+01 452 7.380E+02 493 2.059E+02 534 4.442E+02 575 5.542E+02

412 1.357E+01 453 6.992E+02 494 2.133E+02 535 4.474E+02 576 5.565E+02

413 1.466E+01 454 6.504E+02 495 2.219E+02 536 4.499E+02 577 5.594E+02

414 1.667E+01 455 5.935E+02 496 2.302E+02 537 4.528E+02 578 5.618E+02

415 1.858E+01 456 5.413E+02 497 2.395E+02 538 4.551E+02 579 5.634E+02

416 2.080E+01 457 4.929E+02 498 2.485E+02 539 4.578E+02 580 5.664E+02

417 2.365E+01 458 4.514E+02 499 2.569E+02 540 4.589E+02 581 5.684E+02

418 2.660E+01 459 4.200E+02 500 2.667E+02 541 4.612E+02 582 5.696E+02

419 2.958E+01 460 3.932E+02 501 2.755E+02 542 4.644E+02 583 5.716E+02

420 3.329E+01 461 3.733E+02 502 2.846E+02 543 4.657E+02 584 5.735E+02

0.0

0.2

0.4

0.6

0.8

1.0

380 430 480 530 580 630 680 730 780

Page 9: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711052-10 Page 9 of 15

nm mW nm mW nm mW nm mW nm mW

585 5.743E+02 626 4.546E+02 667 1.871E+02 708 5.535E+01 749 1.572E+01

586 5.753E+02 627 4.479E+02 668 1.818E+02 709 5.381E+01 750 1.530E+01

587 5.772E+02 628 4.417E+02 669 1.769E+02 710 5.221E+01 751 1.501E+01

588 5.779E+02 629 4.349E+02 670 1.720E+02 711 5.097E+01 752 1.459E+01

589 5.788E+02 630 4.275E+02 671 1.674E+02 712 4.937E+01 753 1.412E+01

590 5.790E+02 631 4.202E+02 672 1.629E+02 713 4.771E+01 754 1.368E+01

591 5.798E+02 632 4.136E+02 673 1.577E+02 714 4.611E+01 755 1.336E+01

592 5.797E+02 633 4.062E+02 674 1.540E+02 715 4.443E+01 756 1.293E+01

593 5.784E+02 634 3.990E+02 675 1.496E+02 716 4.325E+01 757 1.238E+01

594 5.787E+02 635 3.921E+02 676 1.458E+02 717 4.216E+01 758 1.225E+01

595 5.778E+02 636 3.853E+02 677 1.412E+02 718 4.057E+01 759 1.189E+01

596 5.778E+02 637 3.777E+02 678 1.381E+02 719 3.957E+01 760 1.151E+01

597 5.769E+02 638 3.713E+02 679 1.338E+02 720 3.820E+01 761 1.116E+01

598 5.753E+02 639 3.634E+02 680 1.296E+02 721 3.731E+01 762 1.112E+01

599 5.742E+02 640 3.561E+02 681 1.260E+02 722 3.586E+01 763 1.070E+01

600 5.720E+02 641 3.491E+02 682 1.225E+02 723 3.499E+01 764 1.012E+01

601 5.708E+02 642 3.419E+02 683 1.189E+02 724 3.382E+01 765 1.003E+01

602 5.680E+02 643 3.351E+02 684 1.152E+02 725 3.279E+01 766 9.745E+00

603 5.660E+02 644 3.282E+02 685 1.122E+02 726 3.178E+01 767 9.498E+00

604 5.623E+02 645 3.212E+02 686 1.089E+02 727 3.099E+01 768 9.133E+00

605 5.608E+02 646 3.140E+02 687 1.054E+02 728 2.991E+01 769 8.769E+00

606 5.578E+02 647 3.077E+02 688 1.026E+02 729 2.911E+01 770 8.503E+00

607 5.545E+02 648 3.004E+02 689 9.928E+01 730 2.797E+01 771 8.317E+00

608 5.512E+02 649 2.938E+02 690 9.660E+01 731 2.718E+01 772 8.147E+00

609 5.471E+02 650 2.877E+02 691 9.368E+01 732 2.644E+01 773 7.966E+00

610 5.434E+02 651 2.807E+02 692 9.095E+01 733 2.551E+01 774 7.737E+00

611 5.397E+02 652 2.740E+02 693 8.818E+01 734 2.471E+01 775 7.520E+00

612 5.343E+02 653 2.680E+02 694 8.545E+01 735 2.399E+01 776 7.302E+00

613 5.292E+02 654 2.616E+02 695 8.279E+01 736 2.338E+01 777 7.108E+00

614 5.246E+02 655 2.549E+02 696 8.050E+01 737 2.276E+01 778 7.082E+00

615 5.198E+02 656 2.482E+02 697 7.803E+01 738 2.212E+01 779 7.096E+00

616 5.144E+02 657 2.428E+02 698 7.568E+01 739 2.134E+01 780 7.109E+00

617 5.095E+02 658 2.364E+02 699 7.354E+01 740 2.059E+01

618 5.037E+02 659 2.306E+02 700 7.117E+01 741 2.029E+01

619 4.987E+02 660 2.253E+02 701 6.916E+01 742 1.926E+01

620 4.923E+02 661 2.185E+02 702 6.689E+01 743 1.911E+01

621 4.866E+02 662 2.139E+02 703 6.549E+01 744 1.817E+01

622 4.809E+02 663 2.081E+02 704 6.272E+01 745 1.788E+01

623 4.739E+02 664 2.022E+02 705 6.082E+01 746 1.745E+01

624 4.675E+02 665 1.971E+02 706 5.928E+01 747 1.670E+01

625 4.613E+02 666 1.920E+02 707 5.731E+01 748 1.612E+01

Page 10: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711052-10 Page 10 of 15

CIE 1931 x y Chromaticity Diagram

7-Step Chromaticity Quadrangles

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

0.30

0.35

0.40

0.45

0.30 0.35 0.40 0.45 0.50 0.55

sample

7-STEP 2200K

7-STEP 2500K

7-STEP 2700K

7-STEP 3000K

7-STEP 3500K

7-STEP 4000K

7-STEP 4500K

7-STEP 5000K

7-STEP 5700K

7-STEP 6500K

Page 11: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711052-10 Page 11 of 15

[Goniophotometer System]

Total operating time for luminous intensity distribution: 1.0 hour

Test orientation: Downward

Electrical Measurement

Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor

230.1 50 0.9887 224.1 0.9853

Photometric Measurement

Luminous Flux (lm) Efficacy (lm/W) Imax (cd) S/MH (C0/180) S/MH (C90/270)

34114.2 152.21 12340.0 1.31 1.30

Luminous Intensity Distribution

C0/180 C45/225 C90/270 C135/315 AVG.

Beam Angle (50% Imax): 115.4 114.9 115.2 115.6 115.3

Field Angle (10% Imax): 149.7 149.6 149.6 149.7 149.7

Page 12: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711052-10 Page 12 of 15

Luminous Intensity (cd) Distribution Data

C

0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° γ

0.0° 12338 12338 12338 12338 12338 12338 12338 12338

5.0° 12296 12292 12296 12296 12298 12308 12314 12318

10.0° 12203 12187 12182 12184 12198 12208 12223 12235

15.0° 12014 12000 11987 11997 12012 12036 12075 12095

20.0° 11738 11720 11699 11716 11732 11799 11848 11880

25.0° 11347 11294 11287 11295 11339 11416 11507 11545

30.0° 10738 10696 10666 10683 10722 10807 10902 10980

35.0° 9832 9855 9864 9884 9918 9994 10074 10103

40.0° 8835 8905 8966 8995 9016 9055 9095 9101

45.0° 8016 8086 8142 8186 8202 8205 8190 8198

50.0° 7354 7368 7404 7448 7481 7507 7524 7570

55.0° 6524 6495 6511 6564 6626 6704 6763 6838

60.0° 5411 5364 5379 5456 5558 5648 5740 5780

65.0° 4167 4118 4134 4208 4322 4423 4509 4583

70.0° 2542 2533 2574 2663 2776 2883 2998 3060

75.0° 945 945 986 1044 1125 1225 1300 1362

80.0° 85 86 95 118 154 205 238 289

85.0° 5 5 6 6 7 8 9 9

90.0° 1 1 1 1 1 1 1 1

95.0° 2 2 2 2 2 2 2 2

100.0° 3 3 3 3 3 3 3 3

105.0° 4 4 4 4 4 3 3 3

110.0° 4 4 4 4 4 4 4 4

115.0° 4 4 4 4 4 4 4 4

120.0° 4 4 4 4 4 4 4 4

125.0° 5 5 5 5 5 5 5 5

130.0° 6 6 6 6 6 6 6 5

135.0° 7 7 7 7 7 7 7 7

140.0° 8 9 9 9 9 9 9 8

145.0° 11 11 11 11 12 12 11 10

150.0° 12 13 14 14 14 14 14 13

155.0° 14 15 15 15 15 16 15 15

160.0° 16 16 16 17 16 17 17 16

165.0° 16 16 16 16 16 17 17 16

170.0° 15 15 15 15 15 15 16 15

175.0° 15 15 14 14 14 14 15 15

180.0° 13 13 12 12 12 12 13 13

Page 13: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711052-10 Page 13 of 15

Luminous Intensity (cd) Distribution Data (cont.)

C

180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° γ

0.0° 12338 12338 12338 12338 12338 12338 12338 12338

5.0° 12324 12322 12326 12328 12322 12316 12312 12306

10.0° 12253 12250 12245 12253 12235 12233 12229 12224

15.0° 12125 12120 12102 12129 12091 12093 12089 12078

20.0° 11902 11911 11894 11883 11847 11862 11851 11827

25.0° 11600 11564 11540 11517 11504 11504 11498 11456

30.0° 11071 11023 10959 10933 10916 10913 10885 10842

35.0° 10245 10263 10220 10173 10131 10099 10040 9944

40.0° 9257 9348 9345 9294 9227 9165 9050 8934

45.0° 8321 8439 8477 8463 8399 8298 8172 8084

50.0° 7642 7710 7737 7727 7665 7575 7488 7453

55.0° 6892 6892 6886 6859 6805 6756 6696 6667

60.0° 5859 5801 5772 5735 5684 5653 5597 5542

65.0° 4487 4448 4413 4367 4315 4222 4126 4136

70.0° 2970 2944 2913 2840 2734 2638 2558 2500

75.0° 1423 1400 1364 1303 1237 1162 1100 1029

80.0° 325 314 282 293 261 227 174 164

85.0° 12 13 13 12 10 8 7 6

90.0° 1 1 1 1 1 1 1 1

95.0° 1 1 1 1 1 1 1 1

100.0° 1 1 1 1 1 1 1 1

105.0° 2 2 2 2 2 2 2 2

110.0° 2 2 2 2 2 2 2 2

115.0° 3 3 3 3 3 3 3 3

120.0° 3 3 3 3 3 3 3 3

125.0° 4 4 4 4 4 4 4 4

130.0° 5 5 5 5 5 5 5 5

135.0° 6 6 6 6 6 6 6 6

140.0° 7 7 7 7 6 7 7 7

145.0° 7 7 7 8 8 8 8 8

150.0° 8 8 8 8 9 8 8 8

155.0° 9 8 9 9 9 9 9 10

160.0° 10 9 10 10 10 10 9 10

165.0° 10 10 10 10 10 10 10 10

170.0° 11 10 10 10 10 10 10 11

175.0° 11 11 11 11 11 10 11 11

180.0° 13 13 13 13 12 12 13 13

Page 14: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711052-10 Page 14 of 15

Zonal Lumen Density Measurement

Deg Flux (lm) %

Deg Flux (lm) %

0-5 294.7 0.86 0-5 294.7 0.86

5-10 877.6 2.58 0-10 1172.3 3.44

10-15 1440.8 4.22 0-15 2613.1 7.66

15-20 1968.9 5.77 0-20 4582.0 13.43

20-25 2442.1 7.16 0-25 7024.1 20.59

25-30 2826.9 8.29 0-30 9851.0 28.88

30-35 3078.2 9.02 0-35 12929.2 37.90

35-40 3193.2 9.36 0-40 16122.3 47.26

40-45 3200.5 9.38 0-45 19322.8 56.64

45-50 3187.2 9.34 0-50 22510.0 65.98

50-55 3106.3 9.11 0-55 25616.4 75.09

55-60 2859.3 8.38 0-60 28475.6 83.47

60-65 2418.9 7.09 0-65 30894.5 90.56

65-70 1798.5 5.27 0-70 32693.0 95.83

70-75 1014.9 2.98 0-75 33707.9 98.81

75-80 338.4 0.99 0-80 34046.3 99.80

80-85 33.2 0.10 0-85 34079.4 99.90

85-90 1.9 0.00 0-90 34081.3 99.90

90-95 0.7 0.01 0-95 34082.0 99.91

95-100 1.0 0.00 0-100 34083.0 99.91

100-105 1.3 0.00 0-105 34084.3 99.91

105-110 1.5 0.01 0-110 34085.8 99.92

110-115 1.6 0.00 0-115 34087.4 99.92

115-120 1.7 0.01 0-120 34089.1 99.93

120-125 1.9 0.00 0-125 34090.9 99.93

125-130 2.1 0.01 0-130 34093.0 99.94

130-135 2.3 0.00 0-135 34095.3 99.94

135-140 2.6 0.01 0-140 34097.9 99.95

140-145 2.8 0.01 0-145 34100.8 99.96

145-150 3.0 0.01 0-150 34103.7 99.97

150-155 2.9 0.01 0-155 34106.6 99.98

155-160 2.7 0.01 0-160 34109.3 99.99

160-165 2.2 0.00 0-165 34111.5 99.99

165-170 1.6 0.01 0-170 34113.0 100.00

170-175 0.9 0.00 0-175 34113.9 100.00

175-180 0.3 0.00 0-180 34114.2 100.00

Page 15: IES LM-79-08 TEST REPORT HBL/HE...IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits –

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China. The NVLAP Lab Code is 200707-0

Report No. R2DG170711052-10 Page 15 of 15

[Additional Test]

Test Item Test Voltage (V) Frequency (Hz) Test Result

Total Harmonic Distortion: 230.0 50 9.58%

6. Product Photo

***********END OF REPORT***********