Size of the Category 7 A Installed Base IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 Waikoloa, HI Valerie Maguire, The Siemon Company

IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

Embed Size (px)

Citation preview

Page 1: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

Size of the Category 7 A Installed Base

IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T)

July, 2015Waikoloa, HI

Valerie Maguire, The Siemon Company

Page 2: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

Supporters

• German Feyh, Broadcom

• Tom Souvignier, Broadcom

• Yong Kim, Broadcom

• Yakov Belopolsky, Bel Stewart

• Dave Hess, Cord Data

• Alan Flatman, LAN Technologies

• Yvan Engels, LEONI Kerpen

• Martin Rossbach, Nexans

Page 3: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

Objectives

• Use third party data to make an assessment of the installed base of category 7A cabling in the data center

• Use third party data to make an assessment of the percentage of end-users that have some category 7A cabling installed in their data center

• Remind the group of the multiple technical contributions demonstrating that 30m of category 7A cabling should support 25GBASE-T

• Move that 30m of category 7A cabling be incorporated into clause 113.7 of the next IEEE P802.3bq draft for support of 25GBASE-T

Page 4: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

Background reference data

• This contribution updates maguire_1_0513_40GBT.pdf, which used data from the BSRIA World Structured Cabling Study (Nov, 2011)

• Volume and number of drops through the end of 2015 can be conservatively extrapolated from this report (assuming volume for 2012 , 2013, 2014, and 2015 is equivalent to 2011) as follows:– 450 million meters of cable shipped (39.2 + 46.2 + 45.7 + 64.2 +

51.9 x 5)– If the average channel length is 30m (20m solid and 10m

stranded), then 22.5 million drops will be installed– If the average channel length is 40m (30m solid and 10m

stranded), then 15 million drops will be installed– If the average channel length is 50m (40m solid and 10m

stranded), then 11.3 million drops will be installed

Page 5: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

New BSRIA data available (see Annex A)

• BSRIA “Global Data Centres 2014, End-User Survey Results, Report 58108/1, Edition 2, January 2015

• Survey of 326 respondents

– 187 representing enterprise data centers

– 139 representing colocation data centers

• Extracts provided with the kind permission of BSRIA

Page 6: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

Copper: Categories Installed

• 4% of all data center cabling is category 7A

Page 7: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

Copper: Categories Installed - Summary of Means

• However, 12% of colocation and 6% of enterprise data centers have some category 7A cabling installed in them

Page 8: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

Copper: Categories Installed Last 12months

• And, in the last 12 months, 57% of data center end users have purchased category 7A cable - these are potentially 25GBASE-T ready drops!

Page 9: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

Conclusions

• Multiple technical contributions exist demonstrating that up to 30m of the installed base of class FA cabling can support 25GBASE-T– “Cat 7A Channel Analysis”, Stephen Bates– “Class FA Cabling for 25GBASE-T“, Yakov Belopolsky– “ISO/IEC 11801-1 Cabling Characteristics”, Dave Hess– “Comparison of Cat7A Channel and 802.3bq Link Segment

Specification”, Martin Rossbach• 10 to over 20 million installed class FA cabling drops will potentially be

available to support 25GBASE-T by the end of the year• 30m of category 7A should be recognized for support of 25GBASE-T

media and explicitly incorporated into clause 113.7 of the next IEEE P802.3bq draft

Page 10: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

Annex A – Reference BSRIA market information

• The following extracts from BSRIA “Global Data Centres 2014, End-User Survey Results, Report 58108/1, Edition 2, January 2015 in this Annex have been provided with the kind permission of BSRIA

Page 11: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

WM

I Cab

ling

Global Data Centres 2014

End-User Survey Results

By Helen Bedford

Report 58108/1 Edition 2 January 2015

A Published Market Report

Page 12: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

12Global Data Centres 2014 – End-User Survey ResultsReport 58108BSRIA © Page 12Page 12

A BSRIA Published Market Report

Page 13: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

13Global Data Centres 2014 – End-User Survey ResultsReport 58108BSRIA © Page 13Page 13

Contract

Date

Developed for:

Issued by: BSRIA Limited

Old Bracknell Lane West

Bracknell

Berkshire RG12 7AH

United Kingdom

Telephone: +44 (0)1344 465 600

Fax: +44 (0) 1344 465 626

Email: [email protected]

Website: www.bsria.co.uk

No. of slides:

Compiled by:

Approved by:

Edition no.

All rights reserved. No part of this report may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic or mechanical including photocopying, recording or otherwise in full without the written approval of any executive director of BSRIA. This report is only intended to be used within the context described in the text.

Report 58108/1

January 2015

A published market report

Helen Bedford

Lone Hansen

2

Global Data Centres – End-User Survey Results

101

Page 14: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

14Global Data Centres 2014 – End-User Survey ResultsReport 58108BSRIA © Page 14Page 14

Contents

SECTION AND SLIDES PAGE

1. Executive Summary 7

Introduction and Methodology 8

Data Centre End-User Survey - Key Findings 9

2. General Overview 11

Data Centre Survey: Types of Organisations 12

Data Centre Survey: Number of Servers 14

3. Cabling 15

Copper to Fibre Split – Colocation and Enterprise 16

Copper to Fibre Split by Country 17

4. Copper 20

Copper: Categories Installed 21

Copper: Categories Installed last 12months 24

5. Fibre 25

Fibre Installed 26

Fibre cable bought last 12months (volume) 30

Fibre cable bought last 12months (volume) – Verticals Split 31

Fibre cable bought last 12months (volume) – Country Split 32

6. Cabling Trends 33

Cat6A 34

OM3 Cabling 35

OM4 Cabling 36

Singlemode Fibre Cabling 37

Common Types of Cabling Installed - Overview 38

10G Copper Plans 39

Page 4

Page 15: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

15Global Data Centres 2014 – End-User Survey ResultsReport 58108BSRIA © Page 15Page 15

Contents

SECTION AND SLIDES PAGE

7. Point-to-Point Links 40

Structured Cabling versus Point-to-Point 41

Point-to-Point Links - Enterprise and Colocation 42

Point-to-Point - Usage by Country 43

Point-to-Point Links - Installed Base 44

Point-to-Point Links - By Type and Vertical 45

Point-to-Point Links - Reasons for Choice 46

Point-to-Point Links - Problems 47

8. 10G Links 49

10G Copper Links 50

CX4 and SFP+ 51

10G Links: Fibre or Copper Reasons 52

10G Active Equipment 53

10G Copper Links Plans – OM4 54

10G Copper Links 55

9. Speeds 58

Networking Infrastructure Speeds 2014 - 2016 59

10G, 40G, 100G 60

10. Fibre Channel 62

SAN Deployment 63

Fibre Channel Protocols 64

Fibre Channel and FCoE 65

Fibre Channel 66

Page 5

Page 16: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

16Global Data Centres 2014 – End-User Survey ResultsReport 58108BSRIA © Page 16Page 16

Contents

SECTION AND SLIDES PAGE

11. Migration 68

Migration Plans for 2014 69

Pre-terminated Links with MPO – Installed Base 70

Migration Plans 71

QSFP-to-QSFP Cables 72

12. Equipment and Architecture Section 73

Replacement Trends 74

Replacement Trends: Switches 75

Replacement Trends: Servers 76

Replacement Trends: Storage 77

Replacement Trends: Overview 78

ToR, EoR, MoR and Centralised Switching 79

ToR and EoR Installations and Results 81

Pre-configured Solutions: Installation Trends 82

13. Planning and Installation 83

Copper Cable Choice - Reasons 84

Multimode Fibre Choice - Reasons 85

Singlemode Fibre Choice - Reasons 86

Utilisation Levels 87

Impact from Virtualisation 88

Enterprise Segment and Outsourcing Trends 89

Preference for End-to-End System 90

Preference for End-to-End System – by Country 91

14. Decision Making and Specification Process 92

Supplier Choice 93

Specification Process 95

15. Future Expansion Plans 98

Future Expansion Plans – Next 5 Years 99

Factors of Significance on Future Infrastructure 100

Page 6

Page 17: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

17Global Data Centres 2014 – End-User Survey ResultsReport 58108BSRIA © Page 17Page 17

11%

15%16% 16%

17%

6%

10%

3%4%

1% 1%

0%

2%

4%

6%

8%

10%

12%

14%

16%

18%

20%

Cat 5unshielded

Cat 5eunshielded

Cat 5e shielded Cat 6unshielded

Cat 6 shielded Cat 6Aunshielded

Cat 6A shielded Cat 7 (S/FTP) Cat 7A (S/FTP) Cat 8 (F/UTP) Cat 8 (S/FTP)

Breakdown of Copper by Category

Copper: Categories Installed

Source: BSRIA

Which of the following types of copper cabling are currently in

use/installed in your data centre?

n=326

Overall, the biggest share in the

installed base is taken by Cat6 (both

shielded and unshielded) – 33%.

Cat5e is still holding its place in the

Data Centres that participated in the

Survey.

Cat6A accounts for 16%, while Cat 7

and Cat7A have a smaller

percentage of the installed base.

Page 7

Page 18: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

18Global Data Centres 2014 – End-User Survey ResultsReport 58108BSRIA © Page 18Page 18

Copper: Categories Installed – Summary of Means

Source: BSRIA

Which of the following types of copper cabling are currently in

use/installed in your data centre?

Cat 5 Cat 5e(U/UTP)

Cat 5e sh(F/UTP)

Cat 6(U/UTP)

Cat 6 sh(F/UTP)

Cat 6A(U/UTP)

Cat 6Ash(F/UTP)

Cat 7(S/FTP)

Cat 7A(S/FTP) Cat 8

TOTAL 25% 34% 36% 36% 38% 13% 23% 6% 8% 3%Enterprise 20% 30% 29% 35% 33% 13% 20% 6% 6% 2%Colocation 36% 42% 48% 38% 48% 14% 28% 6% 12% 6%

0%

10%

20%

30%

40%

50%

60%

Total Enterprise ColocationBase: All who have at least 1% of copper in DC 146 96 50

Responses 326 187 139

Page 8

Page 19: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

19Global Data Centres 2014 – End-User Survey ResultsReport 58108BSRIA © Page 19Page 19

Total Enterprise ColocationCat 5 unshielded 24% 21% 28%Cat 5e unshielded 30% 25% 37%Cat 5e shielded 35% 41% 29%Cat 6 unshielded 43% 50% 31%Cat 6 shielded 44% 42% 48%Cat 6A unshielded 32% 51% 0%Cat 6A shielded 44% 42% 48%Cat 7 (S/FTP) 22% 28% 10%Cat 7A (S/FTP) 57% 65% 49%Cat 8 (F/UTP) 10% 20% 0%Cat 8 (S/FTP) 7% 0% 10%

0%

10%

20%

30%

40%

50%

60%

70%

Copper Cable by Category: Bought Last 12 Months – Summary of Means

Copper: Categories Installed Last 12months

Source: BSRIA

What percentage of the total volume of each type of copper cable

was bought in the last twelve months?

n=153, overall responses=326Note: The Cat5 cabling installed in the last 12 months has been in China and Brazil.

We believe that the end-users mix Cat5 and Cat5e in their responses

Page 9

Page 20: IEEE 802.3bq Next Generation BASE-T Task Force (Topic: 25GBASE-T) July, 2015 …€¦ ·  · 2015-07-10Valerie Maguire, The Siemon Company. Supporters • German Feyh, ... • BSRIA

20Global Data Centres 2014 – End-User Survey ResultsReport 58108BSRIA © Page 20Page 20

[Old Bracknell Lane West, Bracknell, Berkshire RG12 7AH United KingdomT: +44 (0) 1344 465 600 | F: +44 (0) 1344 465 626E: [email protected] | W: www.bsria.co.uk

BSRIA’s Worldwide Market Intelligence division is a globally recognised source of strategic market intelligence and consultancy in the building services industry

Reports available for: Air Conditioning, Heating, Renewable Technology, Energy, Smart Homes, Cabling and Building Controls[

Old Bracknell Lane West, Bracknell, Berkshire RG12 7AH United KingdomT: +44 (0) 1344 465 600 | F: +44 (0) 1344 465 626E: [email protected] | W: www.bsria.co.uk

BSRIA’s Worldwide Market Intelligence division is a globally recognised source of strategic market intelligence and consultancy in the building services industry

Reports available for: Air Conditioning, Heating, Renewable Technology, Energy, Smart Homes, Cabling and Building Controls