www.idx.co.za IDX ifm VSE Gateway v1.2 IDX ifm VSE Gateway DATA SHEET The IDX ifm VSE Gateway is a DIN-rail mountable industrial communication gateway that allows real- time vibration monitoring data from the ifm VSE diagnostic device series to be made available via a variety of standard industrial data protocols and/or interfaces. The Gateway has been specifically designed to work with the ifm VSE002 and VSE100 monitoring devices, and connects to up to 10 VSE devices via Ethernet. The IDX Gateway exposes the VSE vibration monitoring data via interfaces based on the RS-232/485 or Ethernet interfaces, such as MODBUS and OPC. Alternatively, a custom protocol interface can be cost-effectively developed if required. The gateway requires minimal configuration when using the OPC DA Server or MODBUS slave interfaces as these are preconfigured as required. Data can be read from the device using an OPC client or MODBUS master, for example, that has been set to read specific data items. Other interface configuration and device setup can be performed from a PC via an Ethernet connection using the IDX Management Console utility. OPC DA Client/Server MODBUS TCP/RTU Master ifm VSE002/100 MODBUS TCP/RTU Slave Custom Ethernet or RS232/485 protocol

IDX ifm VSE Gateway - IDXOnline VSE Gateway/IDX iFM VSE... · IDX ifm VSE Gateway v1.2 FEATURE SUMMARY Supported ifm VSE devices Up to 10 ifm VSE002 or VSE100 devices Supported Gateway

  • Upload
    lethuan

  • View
    233

  • Download
    3

Embed Size (px)

Citation preview

Page 1: IDX ifm VSE Gateway - IDXOnline VSE Gateway/IDX iFM VSE... · IDX ifm VSE Gateway v1.2 FEATURE SUMMARY Supported ifm VSE devices Up to 10 ifm VSE002 or VSE100 devices Supported Gateway

www.idx.co.za IDX ifm VSE Gateway v1.2

IDX ifm VSE Gateway DATA SHEET

The IDX ifm VSE Gateway is a DIN-rail mountable industrial communication gateway that allows real-

time vibration monitoring data from the ifm VSE diagnostic device series to be made available via a

variety of standard industrial data protocols and/or interfaces.

The Gateway has been specifically designed to work with the ifm VSE002 and VSE100 monitoring

devices, and connects to up to 10 VSE devices via Ethernet. The IDX Gateway exposes the VSE

vibration monitoring data via interfaces based on the RS-232/485 or Ethernet interfaces, such as

MODBUS and OPC. Alternatively, a custom protocol interface can be cost-effectively developed if

required.

The gateway requires minimal configuration when using the OPC DA Server or MODBUS slave

interfaces as these are preconfigured as required. Data can be read from the device using an OPC

client or MODBUS master, for example, that has been set to read specific data items. Other

interface configuration and device setup can be performed from a PC via an Ethernet connection

using the IDX Management Console utility.

OPC DA Client/Server

MODBUS TCP/RTU

Master

ifm VSE002/100

MODBUS TCP/RTU Slave

Custom Ethernet or

RS232/485 protocol

Page 2: IDX ifm VSE Gateway - IDXOnline VSE Gateway/IDX iFM VSE... · IDX ifm VSE Gateway v1.2 FEATURE SUMMARY Supported ifm VSE devices Up to 10 ifm VSE002 or VSE100 devices Supported Gateway

www.idx.co.za IDX ifm VSE Gateway v1.2

FEATURE SUMMARY

Supported ifm VSE devices Up to 10 ifm VSE002 or VSE100 devices

Supported Gateway Interfaces

MODBUS TCP Master/Slave, MODBUS RTU Master/Slave. OPC DA Client/Server, other Ethernet or RS-232/485 interfaces available on request.

Physical Interface options 2 x Ethernet 1Gbps, 4 x RS-232/422/485 (non-isolated) interfaces. Multiple interfaces can be used simultaneously.

VSE Vibration Monitoring Data Available

32 Counter Values 24 Object Level Values, Flags, Level Warning, Level Damage, Emphasised Result, Hysteresis Warning, Hysteresis Damage, RPM Value 24 RPM Object Values 2 Auxiliary Input Value 2 Auxiliary Input Flags 1 Digital Input/output Flags 1 Auxiliary Output Value 1 Auxiliary Output Flags 1 Auxiliary Mapped Object Value 84 Sub Object Values, Flags, Option Value, RPM Value

Maximum Data Refresh Rate

1000 ms

VSE Configuration/Meta data

Connected VSE device configuration can be exported to text file

IDX Gateway Configuration Preconfigured to expose all available VSE data items. Additional configuration is performed using the IDX Management Console Windows tool (connection via Ethernet).

Dimensions (WxDxH) 48 x 110 x 155mm

Power Requirements 12-24V DC, 18W typical

Operating temperature -20 to +70 °C ambient

Mounting DIN rail