1
SWITCHOVER MANIFOLD SYSTEMS 1 LIQUID NITROGEN CRYO-FREEZER (Supplied by Others) HIGH PRESSURE LIQUID NITROGEN CYLINDER GAS WITHDRAWAL Liquid Nitrogen Liquid Nitrogen LABORATORY GAS CONTROL VALVES CLOSE ONLY IN EMERGENCY PULL RING TO ACCESS NNNNNNCRYO FREEZER ROOM CYLINDER STORAGE ROOM ANALYTICAL LABORATORY INCUBATOR ROOM CYLINDER DISCHARGING EQUIPMENT 1 CFAM500 - Manifold, Fully Auto, Cryogenic 2 2 AFAM350R - Manifold, Fully Auto, with Reserve CYLINDER CONTAINMENT 6 D 3000 - Delivery Panel, 5-Valve, Stain. Steel P 7 IGC-1 - Gas Cabinet, Single Cylinder 13 3 AFAM3000 - Manifold, Fully Auto, High Purity 3 4 SIM3000 - Manifold, Simplex, Reserve 4 6 N13 A HELIUM CYLINDER HELIUM CYLINDER HELIUM CYLINDER HELIUM CYLINDER HELIUM CYLINDER HELIUM CYLINDER HIGH PRESSURE LIQUID NITROGEN CYLINDER GAS WITHDRAWAL NITROGEN CYLINDER NITROGEN CYLINDER NITROGEN CYLINDER NITROGEN CYLINDER NITROGEN CYLINDER HYDROGEN CYLINDER LOW PRESSURE LIQUID NITROGEN CYLINDER LIQUID WITHDRAWAL LOW PRESSURE LIQUID NITROGEN CYLINDER LIQUID WITHDRAWAL 17 14 14 7 INCUBATOR (Supplied by Others) INCUBATOR (Supplied by Others) INCUBATOR (Supplied by Others) GAS CHROMATOGRAPH (Supplied by Others) GAS CHROMATOGRAPH (Supplied by Others) 18 18 16 22 21 22 5 CARBON DIOXIDE CYLINDER Gas Monitor 8 9 10 5 PSB3000 - Protocol Station, High Purity ALARMS & CONTROLS 13 13 13 14 15 PIPELINE EQUIPMENT 13 HBV3000 - Ball Valve, Instrument, High Purity 14 HCV3000 - Check Valve, High Purity 15 M 1000 - Multi-Purifier Panel P 16 ZVBL - Zone Valve Box - 3 Valves, High Purity 17 Vacuum Jacketed Pipe, Bayonnet-Style POINT-OF-USE 18 MRP1000 - Modular Regulator Panel 19 MPP250 - Modular Filter Panel 20 MVP1000 - Modular Valve Panel 21 CRP1000 - Compact Regulator Panel 22 DMR600 - Deck Mounted Regulator 8 FGM - Gas Monitor, Oxygen Depletion, Wireless 9 FGM - Gas Monitor, Carbon Dioxide, Wireless 10 FGM - Gas Monitor, Hydrogen, Wireless 11 11 MAB Series - Master Alarm Box for Manifolds OFFICE 12 12 GDC - Gas Detection Controller, Wireless 19 20 GAS GENERATORS A HGG - Gas Generator, Hydrogen, 99.9999% Pure Ideal Solutions: From Design to Completion to Start-Up - From Gas Source to the Point-of-Use Carbon Dioxide Hydrogen Nitrogen Helium PIPELINE COLOR LEGEND Gas Monitor Gas Monitor

Ideal Solutions: From Design to Completion to Start-Up ...€¦ · 18 18 16 22 21 22 5 CARBON DIOXIDE CYLINDER Gas Monitor POWER LOW ALARM HIGH ALARM MODEL VOLT Hz Amp. SERIAL BUZZER

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Ideal Solutions: From Design to Completion to Start-Up ...€¦ · 18 18 16 22 21 22 5 CARBON DIOXIDE CYLINDER Gas Monitor POWER LOW ALARM HIGH ALARM MODEL VOLT Hz Amp. SERIAL BUZZER

CGA 540

CGA 540

CGA 540

CG

A 5

40

CG

A 5

40

CG

A 5

40

IN USE

LEFTBANK

IN USE

RIGHTBANK

Empty WhenNot Lit

Empty WhenNot Lit

LOW PRESSURE ALARM

SILENCE

FULLY AUTOMATIC SWITCHOVERCONTROL MODULE

P/N: SQ1-FASB-23

NORMALPRESSURE

(READY)

NORMALPRESSURE

(READY)

SWITCHOVER MANIFOLD SYSTEMS

OUTLET PRESSUREADJUSTMENT

150

200100

50

0

250

300

150

200100

50

0

250

300

200

300100

0 400

150

200100

50

0

250

300

150

200100

50

0

250

300

30001000

0 4000

2000

RIGHT BANKPRESSURE

LEFT BANKPRESSURE

OUTLETPRESSURE

150

200100

50

0

250

300

150

200100

50

0

250

300

30001000

0 4000

2000

P/N: SQ1-HFAM-GAUGE

RIGHT BANK PRESSURELEFT BANK PRESSURE DELIVERY PRESSURE

FULLY AUTOMATICSWITCHOVER MANIFOLD

150

200100

50

0

250

300

150

200100

50

0

250

300

15050

0 200

100 150

200100

50

0

250

300

150

200100

50

0

250

300

300100

0 400

2 00150

200100

50

0

250

300

150

200100

50

0

250

300

300100

0 400

2 00

IN USE

LEFTBANK

IN USE

RIGHTBANK

Empty WhenNot Lit

Empty WhenNot Lit

LOW PRESSURE ALARM

SILENCE

FULLY AUTOMATIC SWITCHOVERCONTROL MODULE

P/N: SQ1-FASB-23

NORMALPRESSURE

(READY)

NORMALPRESSURE

(READY)

CG

A 5

40

CG

A 5

40

CG

A 5

40

CG

A 5

40

CG

A 5

40

150

200

100

50

0250

300

150

200

100

50

0250

300

3000

1000

0

4000 2000150

200

10050

0

250

300

150200

10050

0

250

300

150

50

0

200

100

ALARM BOX FORONE CYLINDER BANK

NORMALPRESSURE

LOW PRESSURE ALARM

SILENCE

1

LIQUID NITROGEN

CRYO-FREEZER

(Supplied by Others)

HIGH PRESSURELIQUID NITROGEN

CYLINDER

GAS WITHDRAWAL

Liquid Nitrogen

Liquid Nitrogen

150

200100

50

0

250

300

150

200100

50

0

250

300

15050

0 200

100

SECTION SHUTOFF VALVECLOSE ONLY IN EMERGENCY

HYDROGENUSE NO OIL

NO. CONTROLS SECTION

150

200100

50

0

250

300

150

200100

50

0

250

300

15050

0 200

100

SECTION SHUTOFF VALVECLOSE ONLY IN EMERGENCY

HYDROGENUSE NO OIL

NO. CONTROLS SECTION

150

200100

50

0

250

300

150

200100

50

0

250

300

15050

0 200

100

SECTION SHUTOFF VALVECLOSE ONLY IN EMERGENCY

HYDROGENUSE NO OIL

NO. CONTROLS SECTION

150

200100

50

0

250

300

150

200100

50

0

250

300

15050

0 200

100

150

200100

50

0

250

300

150

200100

50

0

250

300

15050

0 200

100

150

200100

50

0

250

300

150

200100

50

0

250

300

15050

0 200

100

LABORATORY GAS CONTROL VALVESCLOSE ONLY IN EMERGENCY

PULL RING TO ACCESS

SECTION SHUTOFF VALVECLOSE ONLY IN EMERGENCY

HYDROGENUSE NO OIL

NO. CONTROLS SECTION

SECTION SHUTOFF VALVECLOSE ONLY IN EMERGENCY

HYDROGENUSE NO OIL

NO. CONTROLS SECTION

SECTION SHUTOFF VALVECLOSE ONLY IN EMERGENCY

HYDROGENUSE NO OIL

NO. CONTROLS SECTION

OUTLETPRESSURE

PRESSUREADJUSTMENT

REGULATOR PANEL

CAS:UN

Non-flammable gas (2.2) 0 0

0N2

60

70

50

4030

0

10

20

60

70

50

4030

0

10

20

Nitrogen

OFF

ON

OUTLETPRESSURE

PRESSUREADJUSTMENT

REGULATOR PANEL

CAS:UN

Non-flammable gas (2.2) 0 0

0N2

60

70

50

4030

0

10

20

60

70

50

4030

0

10

20

Nitrogen

OFF

ON

OUTLETPRESSURE

PRESSUREADJUSTMENT

REGULATOR PANEL

CAS:UN

Non-flammable gas (2.2) 0 0

0N2

60

70

50

4030

0

10

20

60

70

50

4030

0

10

20

Nitrogen

OFF

ON

OUTLETPRESSURE

PRESSUREADJUSTMENT

REGULATOR PANEL

60

70

50

4030

0

10

20

60

70

50

4030

0

10

20

VALVE PANEL

OFF

ON

OFF

ON

V1

V2

PIURIFIER PANEL

OFF

ON

CAS:UN

Non-flammable gas (2.2) 0 0

0N2

Nitrogen

OUTLETPRESSURE

PRESSUREADJUSTMENT

REGULATOR PANEL

CAS:UN

Non-flammable gas (2.2) 0 0

0N2

60

70

50

4030

0

10

20

60

70

50

4030

0

10

20

Nitrogen

OFF

ON

OUTLETPRESSURE

PRESSUREADJUSTMENT

REGULATOR PANEL

CAS:UN

Non-flammable gas (2.2) 0 0

0N2

60

70

50

4030

0

10

20

60

70

50

4030

0

10

20

Nitrogen

OFF

ON

CRYO FREEZER ROOMCYLINDER STORAGE ROOM

ANALYTICAL LABORATORY INCUBATOR ROOM

150

200

100

50

0250

300

150

200

100

50

0250

300

150 200

100

50

0

250

300

150 200

100

50

0

250

300

REGULATORISOLATION

REGULATORVENT

TOPROCESS

RELIEFVALVE

NITROGENINLET

CYLINDERVENT

PRESSUREADJUSTMENT

NITROGENPURGE

CG

A 5

40

MULTI-PURIFIER PANEL

MODEL NUMBER

MAX. INLET PRES.

TRAP NO. 1

TRAP NO. 2

PROJECT NUMBER

DATE OF MFG.

GAS NAME

CHEMICALFORMULA

UN NUMBERCAS NUMBER

HAZARD CLASS

TRAP NO. 3

CYLINDER DISCHARGING EQUIPMENT1 CFAM500 - Manifold, Fully Auto, Cryogenic

2

2 AFAM350R - Manifold, Fully Auto, with Reserve

CYLINDER CONTAINMENT6 D 3000 - Delivery Panel, 5-Valve, Stain. SteelP7 IGC-1 - Gas Cabinet, Single Cylinder

13

3 AFAM3000 - Manifold, Fully Auto, High Purity

3

4 SIM3000 - Manifold, Simplex, Reserve

4

6

CG

A 5

40

PROTOCOL STATION

MODEL NUMBER

MAX. INLET PRES.

DELIVERY PRES.

ALARM PRESSURE

PROJECT NUMBER

DATE OF MFG.

GAS NAME

CHEMICALFORMULA

UN NUMBERCAS NUMBER

HAZARD CLASS

150

200

100

50

0250

300

150

200

100

50

0250

300

3000

1000

0

4000

2000200

100

50

0

250

300

200

100

50

0

250

300

150

50

0

200

CGA 540

150

200 100

50

0

250

300

150

200 100

50

0

250

300

150 50

0200

100

REGULATOR PANEL

CAS:UN

Non-flammable gas (2.2) 0 0

0N2

Nitrogen

150

200100

50

0

250

300

150

200100

50

0

250

300

15050

0 200

100

150

200100

50

0

250

300

150

200100

50

0

250

300

15050

0 200

100 150

200100

50

0

250

300

150

200100

50

0

250

300

15050

0 200

100

13

A

HELIUMCYLINDER

HELIUMCYLINDER

HELIUMCYLINDER

HELIUMCYLINDER

HELIUMCYLINDER

HELIUMCYLINDER

HIGH PRESSURELIQUID NITROGEN

CYLINDER

GAS WITHDRAWAL

NITROGENCYLINDER

NITROGENCYLINDER

NITROGENCYLINDER

NITROGENCYLINDER

NITROGENCYLINDER

HYDROGENCYLINDER

LOW PRESSURELIQUID NITROGEN

CYLINDER

LIQUIDWITHDRAWAL

LOW PRESSURELIQUID NITROGEN

CYLINDER

LIQUIDWITHDRAWAL

17

1414

7

INCUBATOR

(Supplied by Others)

INCUBATOR

(Supplied by Others)

INCUBATOR

(Supplied by Others)GAS

CHROMATOGRAPH

(Supplied by Others)

GAS

CHROMATOGRAPH

(Supplied by Others)

181816

22

21

22

5

CARBONDIOXIDECYLINDER

Gas Monitor

POWERLOW

ALARMHIGH

ALARM

MODEL

VOLT Hz Amp.

SERIAL

BUZZER

8

9

10

5 PSB3000 - Protocol Station, High Purity

ALARMS & CONTROLS

131313

14

15

PIPELINE EQUIPMENT13 HBV3000 - Ball Valve, Instrument, High Purity14 HCV3000 - Check Valve, High Purity15 M 1000 - Multi-Purifier PanelP16 ZVBL - Zone Valve Box - 3 Valves, High Purity17 Vacuum Jacketed Pipe, Bayonnet-Style

POINT-OF-USE18 MRP1000 - Modular Regulator Panel19 MPP250 - Modular Filter Panel20 MVP1000 - Modular Valve Panel21 CRP1000 - Compact Regulator Panel22 DMR600 - Deck Mounted Regulator

8 FGM - Gas Monitor, Oxygen Depletion, Wireless9 FGM - Gas Monitor, Carbon Dioxide, Wireless

10 FGM - Gas Monitor, Hydrogen, Wireless

EMPTYWHEN LIT

LOW PRESSURE ALARM

SILENCE

MASTER ALARM BOX

P/N: SQ1-MAB-23

EMPTYWHEN LIT

11

11 MAB Series - Master Alarm Box for Manifolds

OFFICE

12

12 GDC - Gas Detection Controller, Wireless

19 20

GAS GENERATORSA HGG - Gas Generator, Hydrogen, 99.9999% Pure

Ideal Solutions: From Design to Completion to Start-Up - From Gas Source to the Point-of-Use

Carbon DioxideHydrogen

NitrogenHelium

PIPELINECOLORLEGEND

Gas Monitor

POWERLOW

ALARMHIGH

ALARM

MODEL

VOLT Hz Amp.

SERIAL

BUZZER

Gas Monitor

POWERLOW

ALARMHIGH

ALARM

MODEL

VOLT Hz Amp.

SERIAL

BUZZER