251
1 ICP Test Report Certification Packet Company name: Littelfuse, Inc. Product Series: 5x20 Fuse Product #: 215xxxXP Issue Date: December 3, 2012 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC, 2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Global EHS Engineer > (1) Parts, sub-materials and unit parts This document covers the 5x20 Fuse RoHS-Compliant series products manufactured by Littelfuse, Inc. Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 RemarksForm 585-047 Rev. A 2/21/06

ICP Test Report Certification Packet/media/electronics_technical/...nov-TEST REPORT NO 4002E11121307.rR02 'The new RoHS directive 201 1/65/EU, on Jul. 21 , 201 1 come into lorce on

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

  • 1

    ICP Test Report Certification Packet

    Company name : Littelfuse, Inc.

    Product Series: 5x20 Fuse

    Product #: 215xxxXP

    Issue Date: December 3, 2012

    It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC,

    2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for

    packing/packaging materials, and for additives and the like in the manufacturing processes.

    In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used

    for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing

    processes, are all composed of the following components.

    Issued by:

    (1) Parts, sub-materials and unit parts

    This document covers the 5x20 Fuse RoHS-Compliant series products manufactured by

    Littelfuse, Inc.

    < Raw Materials Used

    Please see Table 1

    (2) The ICP data on all measurable substances

    Please see appropriate pages as identifed in Table 1

    Remarks:

    Form 585-047 Rev. A 2/21/06

  • 2

    Table 1: List of Raw Materials covered by this report Total Parts Raw Material Part Number Raw Material Description Page(s)

    1 C910510/ 910-553 Cap (Copper Shell)

    Base & Plating 3-6

    2 910-556 Cap Base

    Cap Plating 7-10 11-13

    3 YJ50/YJM (909-449) Ceramic Body 14-24

    4 11-0595 (082xxx) Tinned Wire – Cu99.9MSn 25-31

    5 0042xx Tinned Wire – Cu Clad (CuNi44 Sn) 32-38

    6 687xxx-001 Silver Plated Wire- Ag-Cu Sn Plated 39-44

    7 648901 Yarn 45-53

    8 YT-09 (195116) Flux 54-68

    9 YTW102 (692539-002) Solder 69-73

    10 YTW206 (692529) Solder 74-78

    11

    C030204, 934-073, 934-077, 934-078, 934-084,934-085, 934-089 C030210

    Overcap – Fuses Copper Shell (base and plating)

    79-82

    12 EP608 (087355) HMA-Glue (Epoxy Adhesive) 83-94

    13 091250 Sand Filler 95-101

    14 091251 Sand Filler 102-108

    15 091254 Sand Filler 109-117

    16 425900 Ink-Orange 118-128

    17 425901 Ink- Red 129-139

    18 425902 Ink-Black 140-150

    19 425903 Ink-Yellow 151-161

    20 425904 Ink-Blue 162-172

    21 425906 Ink-Brown 173-183

    22 425907 Ink-Green 184-194

    23 425909 Ink-Grey 195-205

    24 425911 Ink-Violet 206-216

    25 425913 Pale Blue Ink 217-227

    26 C610(909-532) Ceramic Tube KER610 228-251

  • nov'TEST REPORT

    NO.jA002E11121307'1R02 DaG:Dec.t5,2Oi1 page 1 of4Custom6i Suzhou FuHong Eteclronic IndustialCo., L6.AddT€sg: NO.89 WEIDU ROAD, WANGTINGTOWN. XIANGCHENG oIsTRIcT. sUzHoU. CHINAReport on tie subnitied samptes.id to beSample name: Copper shellModsl: /

    Materlal: /D€cripiion: /Buyer: /Supplier: /

    SamPle rcceiwd date: Elec.'13,2011T€dng poriod: From Dec.13,2011 lo Dec.15,2o.l1

    T€lino Reou6tedAs sp€cified by client, to detemine the L€ad, Cadmium, Mercury & Hexavat€nt Chromilm content an the slbmified sampte inaccordance wilh Dircctive 200295/EC (RoHS).

    Te.Uno method:

    T€sling liem Measuring instrument MQLLead (Pb) IEC 62321:2008, section I rcP-oEs 2mg/kgcadmium (cd) IEC 62321:20t,3, s€clion 9 tcPoEs 2 mg/kgllercury (Hg) IEC 62321:2008, section 7 lcPoEs 2 mg/kgChromrum (Cr l'1) IEC 62321:2008, Annex B 0 o2mgkg'

    ---FOR FURTHER DETAILS, PLEASE REFERTOTHE FOLLOWNG PAGE(ST**'

    leg-' 0.02 mg/kg reGrc lo the MQL of sampte extraction tiquid.

    99!9!cis!i-When tesled as specined the submi(ed sample compli€d wilh the rcquirements of commission Decision of 18 Aug 2005amending Directive 2002/95/EC notilied undef document 2005/618/EC.

    Pro,ect Leader /{bjA-L(Engine€r) J 4

    lnsoected bv

    ,**'*''*,n-, [,[rlg-,i ti-Y\

    ,ffi:::j:,,44

    SHENZHEnl AOVTESTINC TECHNO!OGY CO..L.TD,KUI\ISIIAI\I BRANCIi Holline86.512.5510 8000

  • nov.NO,: A002E11121307-1 R02

    TEST REPORT

    Tesled by ICP-OES

    Add the digestion sotutioni thevessel is healed until the sampl€has b€€n dissolved

    Weigh the sample into

    F*_-l-Content (Melal substEle)

    Add the digeslion solutjon, ctose

    the micfowave ves:€|.

    F;;1.-and l\Iercury Content (Plaling)

    To Detenn exavalenl Chromium Content (bojting- wateF extraction): (Metat substrate)

    The sample is digesred in the

    mrcrowave oven iollowing a sp€citic

    decomposilion program.

    Tesl lh€ s€mple solution and the 0.02mg/kg standard solution by UV-VIS.

    Hotline86-512-5510 8000

    To

    +Cooling the vessel, fltet washed and

    filled to the ma* with distilled wat€r.

    Remove the sample, and coolthe beaker to room lemperature,and do the color leadion

    sample in the beaker.Heat 50 mL of Dl waler in the

    beaker to boiling ior 10 min

    To Delemine

    ___+l coorins. rirtei washed and lilled l_-_----|l resteo oy l+fl_*lI

    t o t he ma*w i th D twa te r . I l r n " r ,u rn "n , I l " * ' I

    SHENZHsN AOV TG6TING ICCHITOI"OGY CO.,L'O.KUNAHAN BRANCH a

  • nov'NO.i 4002E11121307-rR02

    5. To O€temine Hexavalent Chromium

    ,':"j":::i v^02

    Place 1-5

    TEST REPORToste:oec15,2011

    Contentin colorless and cotorcd cnromaE coating on metats(Plaljng)

    5 2 Eoiling- wat6F extraction

    Tako the (50+5) cm'?

    sample in the beaker.

    S!IENZHEN AOV'CSTING IECIINOIOGY CO..ITD,KUNSHAN gNANCH Hotlinea6-512-5510 8000

    lf the tesl rcsult is posilive,

    the sample is considercd tohave hexavalenl chromilm

    Compare the

    and lhe 0.02 mg/(qstanda.d solution

    Eoiling- wateF ext€ctjonprccedurc shall be used to

    lfthere is int€rference or it is hard to decide whetherthe sampl€ have tie h€xavatent chromium

    Remove tie sample, and cool

    lhe beaksr to room tempeEture,

    and do the color reaolion

    Heat 50 mlof Dlwaier in the

    beaker lo boiling for 10 min

    Test the sample solution and the 0.02mg/kg standard solution by UV,VIS.

    T€t Re6ult3:

    Unit RoHS

    Limil

    Result

    Substrate Plating'

    Lead (Pb) mg/Kg 1000 N.O. N.O.Cadmium (cd) mg/Kg 100 N.D, N.D.lvercury (Hg) mgn(]s 1000 N.D. N.D.chromium (Crl'I) mg/Kg 1000 Negalive Negative

  • nov-TEST REPORT

    NO 4002E11121307.rR02

    'The new RoHS directive 201 1/65/EU, on Jul. 21 , 201 1 come into lorce on Jan. 03, 20 1 3 the fomat imptementation. Direclive2002,95/EC shall be rcpeated simuttaneousty.

    -specimens, which requested to determine Lead, cadmium and l,rercury conteni, have been dissorved comprererv

    -N.D.=not detected(

  • GTI #,ffiffi,HTest Report

    Report No. RLSZE0o1492l00002

    Applicart DONGGUAN CITY XNHAI METAL PRODUCTS CO.'LTD

    Address I 'ST WEIMING ROAD HENGZENG AV.XINAN COMMUI"IIryTOWN DONGGUAN CITY GUANGDONG PROVINCE

    The following samplqs) and samPle informttion wavwere submitt€d rnd idbehaH of the clientSample NameMateridlSample Received DateTesting Period

    T€st Requ€st€d

    T€st Method

    As specified by client, to test Lead(Pb), Cadrnium(Cd),Hexavalent Chromium(Cr(Vl)) in the submitted sample(s).

    Test Result(s) Please refer io the following page(s).

    age I of4

    GAN

    by/on the

    lc

    033098

    Glnfdd&Chil

    a

    BASE OF CAPBRASS H65Nov. 16,2012Nov. 16, 2012 to Nov. 19, 2012

    Di.d !y

    Appt@dR

    c!!rnE rEslrNg INrEtNAlloNAl cottonNlol{comot.r4lc6ti D755,33tSii'ra cdmplsrn1E ft sll- .orip s ll@cx'e ftn

    Rcvicr€d by

    DdcNov. 19,

    No. I

    Cdlldi€Iffi (S*)Co-Lrt Eofi,li LinNlti{ Zfla BD'a ru Dntrrt

    @4 0 0 - 0 7 8 E . 3 ! 3

    IEC 62121:2008 Ed.l Sec.9

    IEC 612r:2008 Ed.l S€. 9

    IEc 62321:2008 Ed.t Sec-7

    IEC 62121:2C108 Ed.l Annex B

    picL L

    $6i.d ttu4!.

  • GTI

    cl{ra[ r

    I F_}'H.mrylTest RePort

    Report No. R1S2E001492100002

    T€rr R€rrlt(sl

    Page 2 of4

    Tested ltem(s) Result

    Lead(Pb) 13 mgllg

    Cadmium (Cd) N.D.

    Mercury(Hg) N.D,

    Hexavalent Chrom ium(c r(v l)) Negative

    Tested Sample/Part D€scriptioD Metal base

    Note: The sample had bden di,csolved totally tested for Lead, Cadmium'-MDL = Method Detection Linit-N.D. = Not Detected (

  • o

    GTI F_i,H"m,m

    Report No RIS2E001492100002

    Test Process

    1. Lmd(Pb),Cadmiun(cd)

    2, Mercury(Hg)

    3. Hexavalent Chromiun(C(Vl))

    Test Report

    ctuTtt t !st | o rNlElr lal toNAL cottolal lof lconormLnrcr l l 0755-!36S:7i0 Compi:r .r E_m6r .4mcir rr t t . l ' ren c 'n

    Page 3 of4

    @.iif;".,,,

    Weigh saraple ed place it m amicrowave digE'stion ves s el

    Sdecl a test sallplc

    m.aswing about 50t5cnf

    AElyred ty UV-V1s

  • a

    GTI #,mffi,^)#Test Report

    Report No. RLS2E001492100002

    Photo(s) of the sample(s)

    *** End of rcport ***

    The test aeport is effective only with both signatue and sp€cialized stamp. The result(sreport refer only to the sarnple(s) tested. Without written approval of CTI, thisreDroduced exceDt in full.

    Pag. 4 of 4

    shown in thiscan't be

    ccNlaE ta i r |NG tNlERNAlto l tA l co l to l^r ioNComorarnr carr 0755-33681100 Complsrn l E-r3r l conpia 'urdcI Nen com E n ra , , . , ' i i , . i . f l i Ld

    O;';;,;",,,.,,,

  • a

    GTI #,HMJ"M

    Sample Received DateTesting Period

    T€st Requested

    Test Mothod

    Test ReportReport No. RLSZE001492I0O00I

    Applicant DONGGUAN CITY XINHAI METAL PRODUCTS CO.,LDAddress I 'ST WEIMING ROAD HENGZENG AV.XINAN COMMLINITY

    TOWN DONGGUAN CITY CUANGDONG PROVINCE

    The following samplqs) and sample informatiotr was/were submitted andbehalf of the clientSample Name SILVER COLOR PLATING OF CAPMaterial El€ctrolytic Nickel

    Page I of3

    by/on the

    Nov. 16;2012Nov. 16, 2012 to Nov. 19, 2012

    As specifled by client, to test Lead(Pb), Cadmium(cd),Hexavalent Chrcmium(Cr(Vl)) in the subrnitted sample(s).

    T€st Resul(s) Please refer to the following page(s).

    elclliod by

    4rt ov.dty

    Rrvi.&dby

    D& Nov. 19,

    No. I

    a

    1033098

    Cd!f!di! I@bd (Sedd Co-bf Ea8wdbtil Zoc Bs'- ToDitti:t' Cu-fiL.& 6na

    cIt l rE ra5TrN6,NlEtNArroNl! cotPol^l lo l lcodpLi hr cari 0 7 55-l3li I I / i)0 c ompld ril E -fi3r1 I cohpia rl@cl' ce.l .ofr

    .a00.6t t6- ! l l

    T€st Itein(s)

    Ref€r to IEc 62321:2008 Ed.t

    R€fer to IEc 62321:2008 Ed.l

    Refe. to IEC 62321 :2008 Ed. I

    IEC 62321:2008 Ed.l Annex B

    teic.l ltu|gr.

    E 03 ! { 4? . r r c f l i n n

  • o

    GTI lt.)m.ffiirmTest Report

    Report No. RLSzE001492l0000l

    Test€d Sample/Prrt Desc ption silvery plating

    Not€: The wasb€d plrtirg had beon dissolv€d totally test€d for Lead,Mercury.-MDL = Method Detection Limit-N.D. = Not Detected (

  • o

    GTI #-),m.ffi^'Y!Test Report

    Report No. RLSZE00I492I00001 P€e3o f3

    Photo(s) ofthe sample(s)

    +** End of repon ***

    The t€st rcport is elfective onty with both signature and specialized stamp. The shown in thisreport ref€r only to the samplds) test€d. Witlod witten apProval of CTl, thisreorcduced exceot in full.

    can't be

    ct,{nt f t l f l tG rNIElr{ArrotrAt cot?olAI loNcanro aLnl cair !f55-3308r fao lompla'nl E m$l coc'piii rlrc].l' ce1l c.rr

    ,aa 0 0 - 6 1 8 8 . 1 3 3

  • scsI

    Test ReportPOLYFIL AGOBERALLMENDSTMSSE 2OA,

    was/w6re submitted and identified by/on behalfofthe client as:

    Validit nownForQueStiPlease Co ith scs

    No. : CE/2011/84950 D e | 2011112101

    CH€3OO ZUG / SWITZERLAND

    Cu99.9MSn'1'14595

    2011t1lt25201 1t11/25 rO 201I |1',01

    Page: 1 or 7

    rr|| [ltt!|||tlt[t

    The following sample(s)

    S€mple DescriptionBuyer/Order No.Sample Receiving DateTesting Period

    lest Result(a) Plea6eefer to next page(s).

    prqt iadsd Ds Gn ,epd eind bComFiy -r ,: !;t lLr. . . i ; l :r l i l l{ i l rt lrd r qti ' r^rl l i9i: l+,11\- em+,i , -,:r. ift",rl.

    .ysuq8d b b cs€rcond rbns d ssubrd lo Tems ad cd@ l.l:

    o n L y a i d w l h L n h . t m B d c | € d l n !

    E d ftr|tld

    clsnH L.Do'|b.t - Trhd

  • Test ReportPOLYFILAGOBERALLI\4ENDSTRASSE

    T66i R.6ultls)

    PART t.lAME No.1

    No.: CE/2011/84950 Dale :2O114ZO1

    2OA, CH63OO ZUG / SWITZERLAND

    Page'.2 of 7

    t I] t l

    SILVER COLORED METAL WIRE (INCLUDING THE PLATING LAYER)

    Te3t lt6m(s) Unit Method MDLR.3ultNo,l

    Cadmium (Cd) mg/KgWith reterence to IEC 62321r 2008 andperfomed by ICP-AES.

    n.d.Lead (Pb) mgKg 24Mercury (Hg) mS/kS n.d.Hexavalent Chromium Cr(Vl) With reference to IEC 62321: 2008 and

    pedormed by Boiling \r€ter ext€ctionMethod.#

    Negative

    Sum of PBBS

    mgikS With reference to IEC 62321: 2008 andperfomed by GC/MS.

    n.d.Monobromobiphenyl 5 n.d.Dibromobiphenyl 5 n.d.Tribromobiphenyl 5 n.d.Tetrabromobiphenyl 5 n.o.Pontabromobiphenyl n.d,Hexabrcmobiphenyl 5 n.o.Heptabromobiphenyl n.d.Octabromobiphenyl 5 n.d.Nonabrornobiphenyl 5 n.d.Dec€bromobiphenyl 5 n .d .Sum of PBOEa n.d.Monobromodiphenyl ether n.d.Dibromodiphenyl ether 5 n.o.Tribromodipheny! ethe. 5 n.d.Tetrabromodiphenyl ether n.d.Pentabromodiphenyl ether n.d.Hexabrcmodiohenvl ether 5 n.d.Heptabromodiphenyl ether 5 n.o,Octabromodiphenyl ether n.o,Nonabromodiphenyl ether 5 n.d.Decabromodiphenyl ether 5 n.d.

    eGlG{d rh s ied @d €nrclb Bpdcn€ry 'l+ !r ! rlrl . .n 1!ts,:r1,rtilr. ;l'!l* rrn . imri+Al'r-\r jrl4.f4! 1r€11hsdocmdssdby'h€c.mpany&bldlobcffi6|codibGo's*to. e.d'mc romal dmstu suq

    d ^ t ' n d w l h L n h r m B d c r . d ! n d p o B d r t s t o G c s r a n d r h 3 d Mldrrgh6add]Ed'on6un6lh6'm

    t',i!r: :d, dri:_ 11rs6rorPre

  • Test Report No. : CE/2011/84950 Date | 2011h21O1 Page: 3 of 7tl]tIlltltfltttltPOLYFILAG

    OBERALLMENDSTRASSE 2OA, CH€3OO ZUG / SWITZERLAND

    Test ltem(s) Unit method MDL ResultNo.1

    HalogenHalogen-Fluorine (F)(CAS No.: 14762-94-8)

    mg/Kg With reference to BS EN M5A2,2007.Analysis was perfomed by lC.

    50 n,o,

    HalogenChlodne (Cl)(CAS No.: 22537-1s1)

    50 n.d.

    Halogen-Brcmine (Br)(CAS No.r 10097-32-2)

    50 n.d.

    Halogen-lodine (l)(CAS No.i 14362-44-8)

    50 n.d.

    Note :1. mg/kg = ppm : 0.1wf/6 = 1o00ppm2. n.d. = Not Detected3. MDL = Method Detection Limit4 - " - "=No tRegu la led5. '" = Qualitative analysis (No unit)6. # = a. Positive means the presence of CrVl on the tested areas

    b. Negative mgans the absence of C l on the tested areasThe dgteci€d concentration in boiling-lvater-ext€ction solution is equalor greaterthan 0.02 mg/kg with 50 cm,tested areas.

    7. The sample(€) was/wer6 analyzed on behalfof the applicant as mixing sample in one testing. The above result(s)was^^/€re only giv€n as the informality value.

    'nrhstar€Fnd€f ontrorbsmpq3)Idd rhEbd,etsn6ndbGComFny f l t r , l r i 9 ! r . , r l i ] l : r r ! l { : : l : : ; l i ' ! i : l j i A r i i F -5 ! , [ 1 ' e t r ; ' f ' , , ' l ] l t ) [ l i 1 'n3dumd ts6su6d ' l hscomtsny5u*db t csccond1 t r sds

    sib iv 6 10 6 o er 5d b6 @mntft,ltrrsandd odd3undrth€ta mol & €pdud depr 'n ju r, ftd

    +l r l *J l : r (+s610r ) re t7e f +sitlfuirL!{:,r rr ir: i - i.hsror IlF

  • Test Report No. : CE201'1/84950 OaL .2011h2,01 Pager 4

    according to belo\ / flo /

    POLYFILAGOBERALLMENDSTRASSE 2OA, CH63OO ZUG / SWITZERLAND

    1) These sample6were da66olved totally by pre-conditioning methoda Cf' test method excluded )

    Name of the pe6on who made measurement: Climbg€at YangName ofthe pe6on in charge of measurement: Troy Chang3)

    ICP-AES

    Sample Material Dige€tion Acid

    S1eel, copper, aluminum, sold€r Aqua regia, HNO3, HCl, HF, HrO,

    Glass HNO3/HF

    cold, platinum, palladium, ceramic Aqua regia

    Silver HNO3

    Plastic H2SO1, HrOr, HNq, HCI

    Othe.s Any acid to totral digestion

    ii. irei,.or if *q oy t . cop-r " ,g .oo-maa"J ' * .6b i " - ' *dco^d ' * "6 .Edrcn ico@isbdM!os@]bi.*ddb" -'d l,nsdd 6 *,* i5r

    *l iq:i";* @"* -;d.." **o.ooissr,s.ry - r"

    "rd;^ a * -nd .

    rtf:r:: r1lirtii+ 1l i s6 io,t,e tTe t r s lo:)2e 'r7 ffiar(om

    Acid digestion by suitable aciddepended on difierent samplemderial (as belo\ , iable)

    Micro\rave digestion with

    HNO/HCVHF

    Heat to appropriat€

    temperature to e,\tract

    Cool, filter digestate

    through filter1) Alkal iFusion2) HCltodissolve

    at 540 nm by UV-VIS

  • Test ReportPOLYFILAGOBERALLI\4ENDSTRASSE 2OA,

    No. : CE2011184950 Oale'. 201 lh2lo1

    CH43OO ZUG / SWITZERLAND

    Page: 5 of 7

    t l | l [ ] | | I t t | l

    PBB/PBDE1) lllanE of the person2) MnE of the person

    analytical FLOW cHARTwho nEde npasurenEnt: Ronran Wongin charge of nEasurenent Troy Chang

    Scrcen analysis

    " " " " " 1 " " " " " "

    Sanple extraction/So*rlet rEthod

    ConcentratdDiluteE)dracbd solution

    First testing process -----t

    Optional screen process -.--

    Confinmtion process - .>

    -s."pb---_-]--------r-------[S-r-tp]-j-a"arn"-_l-----r----

    Ft ler

    Analysis by GC/liS

    cm€ry r r ' r j l j r ) t r . : r i l i " . : . l ! i * i , ; i i l ' r l t : e l . t i l : i l r t / . 1 \ ' l r Fn . r ' j : 1 . ' t l 6+

    to €sd'o'c ramd dm6tu suq

    d^t ,nd vihin rb rmis ot cr€d s i3'lbr.ohbadd€donsu.ddsera od b. repdued eiceol itul wiher

    ! idsnrzorNe-tu!acirrrer/*l:r/f,!.r +!!4J1i:irlre 02)r!e

    I

  • Test ReportPOLYFIL AGOBERALLMENDSTRASSE

    No. : CE/2011/84950 Daie | 2011h21O1

    2OA. CH-6300 ZUG / SWITZERLAND

    Analytical flow chart of halogen content

    1) Name of the p€rson who lmde rneasuredEntr Rita Chen2) llan€ of the person in charge of nEasurerEdt: Troy Chang

    Page: 6 of 7

    comoad N]r]F,j!:ir.. I tiir lt{!l; ;]]rltl.1!- . r. irtsih-{} I 11 FiT . f!l r19i!+l

    fi"JHl"l;liiii',i!',i.iwi;c"ry"';ti"-"c*""tc"t.^a sriu*-t i*n d..",; ''jbl.n bi... .d c.d*" 6, €. a " ' ' i i a - - o e , " a a . ^ * * ' ; . n b a d " i s d l b d i b m a i o ; d k . d h ;

    ; ; ; q ; ; ; ; oo ,4a t ; . : 6 . ? .€6@- -hsd ; "db . - "b1 .

    r L - I I i d l L a i

    Sarple pretreatrnent / Separation

    Weighting and putting safipte in cell

    Orygen Bomb Cofibustion / Absorption

    Dilution to fixed volurne

    Analysisw€s perfornEd by lC

  • Test Report No. : CE/2011/84950 D€te 2011h2101 Paget 7 of 7tl] tlt II][]lPOLYFILAG

    OBEMLLMENDSTRASSE 2OA, CH63OO ZUG / SWITZERLAND

    * The teeted sample / pa is maaked by an arrow if ifs shown on ih€ pholo. '

    " End of Report -

    €(s) r6rd Th€ r6d rop.n @nd b rccomtsry rirl,,iirar.rr'ir,'r,:111!!1, iilrRj:itr r.il1' l:!11.!-em+iI, ra r';)n:ll 'Thsih{.d"**dbylh6c"np.nysub'db6G4€Ejcond1bngo{sld ,M6.6al &dmsfu' sub]rendir,e'@ d ru d dbn s€s ibrh€! n reieds rhe cmp8.r's t ndn$ 3r rhe-y .d fu " t h " i . 6dc " " c ' * dDc . {5ny r ' j e cdnF i ys9s . s$;nshisandobroa,o3@do,rbta mdsrepd@sxepr'nlu.wM,sio,MtenaFro!3 drhecompanv a

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00300774

    PREPARED AND CHECKED BY: AUTHORIZED BY: FOR INTERTEK TESTING SERVICES FOR INTERTEK TESTING SERVICES LTD., SHANGHAI LTD., SHANGHAI

    MYRA LV JACOB LIN CHEMICAL LAB SENIOR MANAGER GENERAL MANAGER

    PAGE 1 OF 7

    APPLICANT: LITTELFUSE,INC. DATE: FEB 02, 2012 800 E. NORTHWEST HWY ATTN: A. CESISTA/ K. BACILA

    SAMPLE DESCRIPTION: One(1) submitted sample said to be Wire with plating. Part Description : Wire(Elschukon). Part Number : 004206. Date Sample Received : Jan.17, 2012. Date Test Started : Jan.17, 2012. ***********************************************************************

    TESTS CONDUCTED: AS REQUESTED BY THE APPLICANT, FOR DETAILS REFER TO ATTACHED PAGE(S)

    **********************************************************************TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00300774

    TESTS CONDUCTED

    PAGE 2 OF 7

    (Ⅰ) Test Result Summary :

    Result (ppm) Testing Item

    (1)

    Heavy Metal

    Cadmium (Cd) content ND Lead (Pb) content 20 Mercury (Hg) content ND Chromium VI (Cr6+) content (mg/kg with 50cm2)

    Negative (< 0.02)(#)

    Result (ppm)

    Testing Item (2)

    Heavy Metal

    Cadmium (Cd) content/PLATING ND Lead (Pb) content/PLATING 238 Mercury (Hg) content/PLATING ND Chromium VI (Cr6+) content (mg/kg with 50cm2)/PLATING

    Negative (< 0.02)(#)

    Tested components:

    (1) Substrate (2) Plating

    Remarks: ppm = Parts per million = mg/kg ND = Not detected # = Due to the insufficient sample area, reduced total

    sample surface of 10 cm2 was used and the dilution factor was adjusted accordingly.

    mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre

    Negative = A negative test result indicated positive observation was not found at the time of testing.

    Responsibility Of Chemist :Dent Fang / Ken He **********************************************************************

    TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00300774

    TESTS CONDUCTED

    PAGE 3 OF 7

    (Ⅱ) RoHS Requirement: Restricted Substances Limits Cadmium (Cd) Content 0.01% (100ppm)Lead (Pb) Content 0.1% (1000ppm)Mercury (Hg) Content 0.1% (1000ppm)Chromium VI (Cr6+) Content 0.1% (1000ppm)Polybrominated Biphenyls (PBBs) 0.1% (1000ppm)Polybrominated Diphenyl Ehters (PBDEs) 0.1% (1000ppm)

    The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. **********************************************************************

    TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00300774

    TESTS CONDUCTED

    PAGE 4 OF 7

    (Ⅲ) Test Method:

    Testing Item Testing Method Reporting Limit

    Cadmium (Cd) content

    With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.

    2 ppm

    Lead (Pb) content

    With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.

    2 ppm

    Mercury (Hg) content

    With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.

    2 ppm

    Chromium VI (Cr6+) content

    With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis spectrophotometer.

    0.02 mg/kg with

    50cm2

    Remark: Reporting limit = Quantitation limit of analyte in sample

    Date Sample Received :JAN.17, 2012 Testing Period :JAN.17, 2012 TO JAN.21, 2012 **********************************************************************

    TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00300774

    TESTS CONDUCTED

    PAGE 5 OF 7

    (Ⅳ) Measurement Flowchart:

    Test For Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Standard: IEC 62321 edition 1.0:2008

    **********************************************************************TO BE CONTINUED

    sampling/grinding or cutting

    weigh sample and for different

    material, digest the sample with

    make up with deionized water

    Cd/Pb/Hg

    analyzed by ICP-OES

    weigh sample and add alkaline solution

    definite temp.

    make up with deionized water and add diphenyl-

    carbazide solution

    Cr6+

    weigh sample and add organic

    soxhlet extraction or

    solvent extraction

    concentrate the extract and make up with organic

    PBBs/PBDEs

    analyzed by UV-VIS

    analyzed by GC-MSD

    spot test

    get 50cm2 samples

    boiling water extraction

    metalpolymers / electronics

    negative*2confirm the tested samples are totally

    dissolved No

    cool and filter the extract

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00300774

    TESTS CONDUCTED

    PAGE 6 OF 7

    REMARKS:

    *1: List of appropriate acid: Material Acid added for digestion

    Polymers HNO3,HCl,HF,H2O2,H3BO3 Metals HNO3,HCl,HF Electronics HNO3,HCl,H2O2,HBF4

    *2: If the result of spot test is positive, Chromium VI would be determined as detected.

    **********************************************************************TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00300774

    TESTS CONDUCTED

    PAGE 7 OF 7

    **********************************************************************

    END OF REPORT

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00300757

    PREPARED AND CHECKED BY: AUTHORIZED BY: FOR INTERTEK TESTING SERVICES FOR INTERTEK TESTING SERVICES LTD., SHANGHAI LTD., SHANGHAI

    MYRA LV JACOB LIN CHEMICAL LAB SENIOR MANAGER GENERAL MANAGER

    PAGE 1 OF 6

    APPLICANT: LITTELFUSE,INC. DATE: FEB 02, 2012 800 E. NORTHWEST HWY ATTN: A. CESISTA/ K. BACILA

    SAMPLE DESCRIPTION: One(1) submitted sample said to be Wire with plating. Part Description : Wire(Polyil). Part Number : 687279-001. Date Sample Received : Jan.17, 2012. Date Test Started : Jan.17, 2012. ***********************************************************************

    TESTS CONDUCTED: AS REQUESTED BY THE APPLICANT, FOR DETAILS REFER TO ATTACHED PAGE(S)

    *********************************************************************** To Be Continued

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00300757

    TESTS CONDUCTED

    PAGE 2 OF 6

    (Ⅰ) Test Result Summary :

    Result (ppm) Testing Item

    (1)

    Heavy Metal

    Cadmium (Cd) content ND Lead (Pb) content ND Mercury (Hg) content ND Chromium VI (Cr6+) content (mg/kg with 50cm2) Negative (< 0.02)(#)

    Result (ppm)

    Testing Item (2)

    Heavy Metal

    Cadmium (Cd) content/Plating ND Lead (Pb) content/Plating 72 Mercury (Hg) content/Plating ND Chromium VI (Cr6+) content (mg/kg with 50cm2)/Plating

    Negative (< 0.02)(#)

    Tested components:

    (1) Substrate (2) Plating

    Remarks: ppm = Parts per million = mg/kg ND = Not detected # = Due to the insufficient sample area, reduced total

    sample surface of 10 cm2 was used and the dilution factor was adjusted accordingly.

    mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre

    Negative = A negative test result indicated positive observation was not found at the time of testing.

    Responsibility Of Chemist :Dent Fang / Ken He

    Date Sample Received :Jan.17, 2012 Testing Period :Jan.21, 2012 ***********************************************************************

    To Be Continued

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00300757

    TESTS CONDUCTED

    PAGE 3 OF 6

    (Ⅱ) RoHS Requirement: Restricted Substances Limits Cadmium (Cd) Content 0.01% (100ppm)Lead (Pb) Content 0.1% (1000ppm)Mercury (Hg) Content 0.1% (1000ppm)Chromium VI (Cr6+) Content 0.1% (1000ppm)Polybrominated Biphenyls (PBBs) 0.1% (1000ppm)Polybrominated Diphenyl Ehters (PBDEs) 0.1% (1000ppm)

    The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material.

    (Ⅲ) Test Method:

    Testing Item Testing Method Reporting Limit

    Cadmium (Cd) content

    With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.

    2 ppm

    Lead (Pb) content

    With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.

    2 ppm

    Mercury (Hg) content

    With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.

    2 ppm

    Chromium VI (Cr6+) content

    With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis spectrophotometer.

    0.02 mg/kg with

    50cm2

    Remark: Reporting limit = Quantitation limit of analyte in sample ***********************************************************************

    To Be Continued

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00300757

    TESTS CONDUCTED

    PAGE 4 OF 6

    (Ⅳ) Measurement Flowchart:

    Test For Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Standard: IEC 62321 edition 1.0:2008

    *********************************************************************** To Be Continued

    sampling/grinding or cutting

    weigh sample and for different

    material, digest the sample with

    make up with deionized water

    Cd/Pb/Hg

    analyzed by ICP-OES

    weigh sample and add alkaline solution

    definite temp.

    make up with deionized water and add diphenyl-

    carbazide solution

    Cr6+

    weigh sample and add organic

    soxhlet extraction or

    solvent extraction

    concentrate the extract and make up with organic

    PBBs/PBDEs

    analyzed by UV-VIS

    analyzed by GC-MSD

    spot test

    get 50cm2 samples

    boiling water extraction

    metalpolymers / electronics

    negative*2confirm the tested samples are totally

    dissolved No

    cool and filter the extract

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00300757

    TESTS CONDUCTED

    PAGE 5 OF 6

    REMARKS: *1: List of appropriate acid:

    Material Acid added for digestion

    Polymers HNO3,HCl,HF,H2O2,H3BO3 Metals HNO3,HCl,HF Electronics HNO3,HCl,H2O2,HBF4

    *2: If the result of spot test is positive, Chromium VI would be determined as detected.

    *********************************************************************** To Be Continued

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00300757

    TESTS CONDUCTED

    PAGE 6 OF 6

    ***********************************************************************

    End Of Report

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299962

    PREPARED AND CHECKED BY: AUTHORIZED BY: FOR INTERTEK TESTING SERVICES FOR INTERTEK TESTING SERVICES LTD., SHANGHAI LTD., SHANGHAI

    MYRA LV STEPHEN TSANG CHEMICAL LAB SENIOR MANAGER GENERAL MANAGER

    PAGE 1 OF 9

    APPLICANT: LITTELFUSE,INC. DATE: JAN 18, 2012 800 E. NORTHWEST HWY ATTN: A. CESISTA/ K. BACILA

    SAMPLE DESCRIPTION: One(1) submitted sample said to be White yarn. Part Description : YARN. Part Number : 648901. Date Sample Received : Jan.11, 2012. Date Test Started : Jan.11, 2012. ***********************************************************************

    TESTS CONDUCTED: AS REQUESTED BY THE APPLICANT, FOR DETAILS REFER TO ATTACHED PAGE(S)

    **********************************************************************TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299962

    TESTS CONDUCTED

    PAGE 2 OF 9

    1 (I) Test Result Summary :

    Testing Item Result (ppm)

    Halogen Content Fluorine (F) 820 Chlorine (Cl) ND Bromine (Br) ND Iodine (I) ND

    Remarks: ppm = Parts per million based on weight of tested sample =

    mg/kg ND = Not detected

    Responsibility Of Chemist :Ken He

    (II) Test Method:

    Testing Item Testing Method Reporting Limit

    Halogen Content With reference to EN 14582:2007 by combustion flask with oxygen and determined by ion chromatography

    50 ppm

    Remark: Reporting limit = Quantitation limit of analyte in sample **********************************************************************

    TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299962

    TESTS CONDUCTED

    PAGE 3 OF 9

    (III) Measurement Flowchart:

    Test For Halogen Content Reference Standard: EN 14582

    **********************************************************************TO BE CONTINUED

    add absorbent in a combustion flask & place weighed sample in equipment

    fill the combustion flask with oxygen

    ignite then leave the flask at room temperature

    transfer the absorbent into a volumetric flask

    make up with deionized water

    sampling/grinding or cutting

    analyzed by ion chromatography

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299962

    TESTS CONDUCTED

    PAGE 4 OF 9

    2 (I) Test Result Summary :

    Testing Item Result (ppm)

    Heavy Metal

    Cadmium (Cd) content ND Lead (Pb) content ND Mercury (Hg) content ND Chromium VI (Cr6+) content ND

    Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) ND Dibrominated Biphenyls (DiBB) ND Tribrominated Biphenyls (TriBB) ND Tetrabrominated Biphenyls (TetraBB) ND Pentabrominated Biphenyls (PentaBB) ND Hexabrominated Biphenyls (HexaBB) ND Heptabrominated Biphenyls (HeptaBB) ND Octabrominated Biphenyls (OctaBB) ND Nonabrominated Biphenyls (NonaBB) ND Decabrominated Biphenyl (DecaBB) ND

    Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) ND Dibrominated Diphenyl Ethers (DiBDE) ND Tribrominated Diphenyl Ethers (TriBDE) ND Tetrabrominated Diphenyl Ethers (TetraBDE) ND Pentabrominated Diphenyl Ethers (PentaBDE) ND Hexabrominated Diphenyl Ethers (HexaBDE) ND Heptabrominated Diphenyl Ethers (HeptaBDE) ND Octabrominated Diphenyl Ethers (OctaBDE) ND Nonabrominated Diphenyl Ethers (NonaBDE) ND Decabrominated Diphenyl Ether (DecaBDE) ND

    **********************************************************************TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299962

    TESTS CONDUCTED

    PAGE 5 OF 9

    Remarks: ppm = Parts per million = mg/kg ND = Not detected

    Responsibility Of Chemist :Dent Fang / Ken He

    (II) RoHS Requirement:

    Restricted Substances Limits Cadmium (Cd) Content 0.01% (100ppm)Lead (Pb) Content 0.1% (1000ppm)Mercury (Hg) Content 0.1% (1000ppm)Chromium VI (Cr6+) Content 0.1% (1000ppm)Polybrominated Biphenyls (PBBs) 0.1% (1000ppm)Polybrominated Diphenyl Ehters (PBDEs) 0.1% (1000ppm)

    The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. **********************************************************************

    TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299962

    TESTS CONDUCTED

    PAGE 6 OF 9

    (III) Test Method:

    Testing Item Testing Method Reporting Limit

    Cadmium (Cd) content

    With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.

    2 ppm

    Lead (Pb) content

    With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.

    2 ppm

    Mercury (Hg) content

    With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.

    2 ppm

    Chromium VI (Cr6+) content

    With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer.

    1 ppm

    Polybrominated Biphenyls (PBBs)

    With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary.

    5 ppm

    Polybrominated Diphenyl Ethers (PBDEs)

    With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary.

    5 ppm

    Remark: Reporting limit = Quantitation limit of analyte in sample

    DATE SAMPLE RECEIVED : JAN.11, 2012 TESTING PERIOD : JAN.11, 2012 TO JAN.13, 2012

    **********************************************************************TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299962

    TESTS CONDUCTED

    PAGE 7 OF 9

    (IV) Measurement Flowchart:

    Test For Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Standard: IEC 62321 edition 1.0:2008

    **********************************************************************

    TO BE CONTINUED

    sampling/grinding or cutting

    weigh sample and for different

    material, digest the sample with

    make up with deionized water

    Cd/Pb/Hg

    analyzed by ICP-OES

    weigh sample and add alkaline solution

    definite temp.

    make up with deionized water and add diphenyl-

    carbazide solution

    Cr6+

    weigh sample and add organic

    soxhlet extraction or

    solvent extraction

    concentrate the extract and make up with organic

    PBBs/PBDEs

    analyzed by UV-VIS

    analyzed by GC-MSD

    spot test

    get 50cm2 samples

    boiling water extraction

    metalpolymers / electronics

    negative*2confirm the tested samples are totally

    dissolved No

    cool and filter the extract

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299962

    TESTS CONDUCTED

    PAGE 8 OF 9

    REMARKS:

    *1: List of appropriate acid: Material Acid added for digestion Polymers HNO3,HCl,HF,H2O2,H3BO3 Metals HNO3,HCl,HF Electronics HNO3,HCl,H2O2,HBF4

    *2: If the result of spot test is positive, Chromium VI would be determined as detected. **********************************************************************

    TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299962

    TESTS CONDUCTED

    PAGE 9 OF 9

    **********************************************************************

    END OF REPORT

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    PREPARED AND CHECKED BY: AUTHORIZED BY: FOR INTERTEK TESTING SERVICES FOR INTERTEK TESTING SERVICES LTD., SHANGHAI LTD., SHANGHAI

    MYRA LV STEPHEN TSANG CHEMICAL LAB SENIOR MANAGER GENERAL MANAGER

    PAGE 1 OF 15

    APPLICANT: LITTELFUSE,INC. DATE: JAN 18, 2012 800 E. NORTHWEST HWY ATTN: A. CESISTA/ K. BACILA

    SAMPLE DESCRIPTION: One (1) submitted sample said to be Orange Liquid. Part description : FLUX. Part number : 195116. Date sample received : Jan.11, 2012. Date test started : Jan.11, 2012. ***********************************************************************

    TESTS CONDUCTED: AS REQUESTED BY THE APPLICANT, FOR DETAILS REFER TO ATTACHED PAGE(S)

    *********************************************************************** TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    PREPARED AND CHECKED BY: AUTHORIZED BY: FOR INTERTEK TESTING SERVICES FOR INTERTEK TESTING SERVICES LTD., SHANGHAI LTD., SHANGHAI

    MYRA LV STEPHEN TSANG CHEMICAL LAB SENIOR MANAGER GENERAL MANAGER

    PAGE 2 OF 15

    CONCLUSION:

    TESTED SAMPLE/ COMPONENT

    STANDARD RESULT

    TESTED COMPONENT OF SUBMITTED SAMPLE

    PHTHALATES CONTENT REQUIREMENT IN ANNEX XVII ITEMS 51 & 52 OF THE REACH REGULATION (EC) NO. 1907/2006 & AMENDENT NO.552/2009(FORMERLY KNOWN AS DIRECTIVE 2005/84/EC)

    PASS

    TESTED SAMPLE/COMPONENT STANDARD RESULT

    TESTED COMPONENT OF SUBMITTED SAMPLE

    US CONSUMER PRODUCT SAFETY IMPROVEMENT ACT 2008 TITLE I, SEC 108 REQUIREMENT ON PHTHALATES

    PASS

    **********************************************************************

    **********************************************************************

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    TESTS CONDUCTED

    PAGE 3 OF 15

    1 PHTHALATE CONTENT TEST

    WITH REFERENCE TO EN14372, BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY (GC-MS) ANALYSIS.

    LIMIT(%,W/W) TESTED COMPOUND RESULT (%,W/W)

    (MAX.) DIBUTYL PHTHALATE (DBP) ND --- DI(2-ETHYL HEXYL) PHTHALATE(DEHP) ND --- BENZYL BUTYL PHTHALATE (BBP) ND ---

    SUM OF THREE PHTHALATES ND 0.1

    REMARK:THE ABOVE LIMIT WAS QUOTED ACCORDING TO ANNEX XVII ITEMS 51 & 52 OF THE REACH REGULATION (EC) NO. 1907/2006 & AMENDENT NO.552/2009 (FORMERLY KNOWN AS DIRECTIVE 2005/84/EC) FOR PHTHALATE CONTENT IN TOYS AND CHILDREN CARE ARTICLES.

    DETECTION LIMIT = 0.01%(W/W) ND = NOT DETECTED

    *********************************************************************** TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    TESTS CONDUCTED

    PAGE 4 OF 15

    2 (Ⅰ) Test Result Summary :

    Result (ppm) Testing Item

    Halogen Content Fluorine (F) ND Chlorine (Cl) 8200 Bromine (Br) ND Iodine (I) ND

    Remarks: ppm = Parts per million based on weight of tested sample =

    mg/kg ND = Not detected

    Responsibility Of Chemist :Ken He

    (Ⅲ) Test Method:

    Testing Item Testing Method Reporting Limit

    Halogen Content With reference to EN 14582:2007 by combustion flask with oxygen and determined by ion chromatography

    50 ppm

    Remark: Reporting limit = Quantitation limit of analyte in sample **********************************************************************

    TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    TESTS CONDUCTED

    PAGE 5 OF 15

    (Ⅳ) Measurement Flowchart:

    Test For Halogen Content Reference Standard: EN 14582

    **********************************************************************TO BE CONTINUED

    add absorbent in a combustion flask & place weighed sample in equipment

    fill the combustion flask with oxygen

    ignite then leave the flask at room temperature

    transfer the absorbent into a volumetric flask

    make up with deionized water

    sampling/grinding or cutting

    analyzed by ion chromatography

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    TESTS CONDUCTED

    PAGE 6 OF 15

    3 (Ⅰ) Test Result Summary :

    Testing Item Result (ppm)

    Heavy Metal

    Cadmium (Cd) content ND Lead (Pb) content ND Mercury (Hg) content ND Chromium VI (Cr6+) content ND

    Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) ND Dibrominated Biphenyls (DiBB) ND Tribrominated Biphenyls (TriBB) ND Tetrabrominated Biphenyls (TetraBB) ND Pentabrominated Biphenyls (PentaBB) ND Hexabrominated Biphenyls (HexaBB) ND Heptabrominated Biphenyls (HeptaBB) ND Octabrominated Biphenyls (OctaBB) ND Nonabrominated Biphenyls (NonaBB) ND Decabrominated Biphenyl (DecaBB) ND

    Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) ND Dibrominated Diphenyl Ethers (DiBDE) ND Tribrominated Diphenyl Ethers (TriBDE) ND Tetrabrominated Diphenyl Ethers (TetraBDE) ND Pentabrominated Diphenyl Ethers (PentaBDE) ND Hexabrominated Diphenyl Ethers (HexaBDE) ND Heptabrominated Diphenyl Ethers (HeptaBDE) ND Octabrominated Diphenyl Ethers (OctaBDE) ND Nonabrominated Diphenyl Ethers (NonaBDE) ND Decabrominated Diphenyl Ether (DecaBDE) ND

    **********************************************************************TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    TESTS CONDUCTED

    PAGE 7 OF 15

    Remarks: ppm = Parts per million = mg/kg ND = Not detected

    Responsibility Of Chemist :Dent Fang / Ken He

    (Ⅱ) RoHS Requirement: Restricted Substances Limits Cadmium (Cd) Content 0.01% (100ppm)Lead (Pb) Content 0.1% (1000ppm)Mercury (Hg) Content 0.1% (1000ppm)Chromium VI (Cr6+) Content 0.1% (1000ppm)Polybrominated Biphenyls (PBBs) 0.1% (1000ppm)Polybrominated Diphenyl Ehters (PBDEs) 0.1% (1000ppm)

    The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. **********************************************************************

    TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    TESTS CONDUCTED

    PAGE 8 OF 15

    (Ⅲ) Test Method:

    Testing Item Testing Method Reporting Limit

    Cadmium (Cd) content

    With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.

    2 ppm

    Lead (Pb) content

    With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.

    2 ppm

    Mercury (Hg) content

    With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.

    2 ppm

    Chromium VI (Cr6+) content

    With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer.

    1 ppm

    Polybrominated Biphenyls (PBBs)

    With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary.

    5 ppm

    Polybrominated Diphenyl Ethers (PBDEs)

    With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary.

    5 ppm

    Remark: Reporting limit = Quantitation limit of analyte in sample ***********************************************************************

    TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    TESTS CONDUCTED

    PAGE 9 OF 15

    (Ⅳ) Measurement Flowchart:

    Test For Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Standard: IEC 62321 edition 1.0:2008

    **********************************************************************

    TO BE CONTINUED

    sampling/grinding or cutting

    weigh sample and for different

    material, digest the sample with

    make up with deionized water

    Cd/Pb/Hg

    analyzed by ICP-OES

    weigh sample and add alkaline solution

    definite temp.

    make up with deionized water and add diphenyl-

    carbazide solution

    Cr6+

    weigh sample and add organic

    soxhlet extraction or

    solvent extraction

    concentrate the extract and make up with organic

    PBBs/PBDEs

    analyzed by UV-VIS

    analyzed by GC-MSD

    spot test

    get 50cm2 samples

    boiling water extraction

    metalpolymers / electronics

    negative*2confirm the tested samples are totally

    dissolved No

    cool and filter the extract

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    TESTS CONDUCTED

    PAGE 10 OF 15

    REMARKS:

    *1: List of appropriate acid: Material Acid added for digestion

    Polymers HNO3,HCl,HF,H2O2,H3BO3 Metals HNO3,HCl,HF Electronics HNO3,HCl,H2O2,HBF4

    *2: If the result of spot test is positive, Chromium VI would be determined as detected. **********************************************************************

    TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    TESTS CONDUCTED

    PAGE 11 OF 15

    (Ⅳ) Measurement Flowchart:

    Test For Halogen Content Reference Standard: EN 14582

    add absorbent in a combustion flask & place weighed sample in equipment

    fill the combustion flask with oxygen

    ignite then leave the flask at room temperature

    transfer the absorbent into a volumetric flask

    make up with deionized water

    sampling/grinding or cutting

    analyzed by ion chromatography

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    TESTS CONDUCTED

    PAGE 12 OF 15

    4 PHTHALATE CONTENT TEST

    WITH REFERENCE TO ASTM D3421, BY GAS CHROMATOGRAPHY-MASS

    SPECTROMETRY (GC-MS) ANALYSIS.

    RESULT (%, w/w) LIMIT (%, w/w) (MAX.) DIBUTYL PHTHALATE (DBP) ND 0.1 DI(2-ETHYL HEXYL) PHTHALATE (DEHP) ND 0.1 BENZYL BUTYL PHTHALATE (BBP) ND 0.1

    REMARK:THE ABOVE LIMIT WAS QUOTED ACCORDING TO US CONSUMER

    PRODUCT SAFETY IMPROVEMENT ACT 2008 FOR PROHIBITION ON SALE OF CERTAIN PRODUCTS CONTAINING SPECIFIED PHTHALATES.

    DETECTION LIMIT = 0.01% (w/w) ND = NOT DETECTED

    *********************************************************************** TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    TESTS CONDUCTED

    PAGE 13 OF 15

    MEASUREMENT FLOWCHART: TEST FOR PHTHALATES CONTENTS

    *********************************************************************** TO BE CONTINUED

    Weigh sample and place in a thimble

    Extracted by Soxhlet extraction with organic solvent

    Concentrate the extract

    Analyze by GC-MSD

    Make up with organic solvent

    Transfer the extract into a volumetric flask

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    TESTS CONDUCTED

    PAGE 14 OF 15

    5 TEST RESULT SUMMARY:

    TESTING ITEM RESULT(ppm)

    HBCD (HEXABROMOCYCLODODECANE) ND

    REMARKS: ppm = PARTS PER MILLION = mg/kg ND = NOT DETECTED (B) TEST METHOD :

    TESTING ITEM TESTING METHOD REPORTING

    LIMIT

    HBCD (HEXABROMOCYCLODODECANE)

    WITH REFERENCE TO USEPA 3540C, BY SOLVENT EXTRACTION AND DETERMINED BY GC/MS

    10 ppm

    DATE SAMPLE RECEIVED : JAN.11, 2012 TESTING PERIOD : JAN.11, 2012 TO JAN.16, 2012

    *********************************************************************** TO BE CONTINUED

  • Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338

    TEST REPORT NUMBER: SHAH00299991

    TESTS CONDUCTED

    PAGE 15 OF 15

    ***********************************************************************

    END OF REPORT

  • Test R€port No. SHAEC1216714750 Date: 25 Sep 2012 Page 'l ofsZHEJIANG ASIA GENERAL SOLDERING&BRAZING MATERIAL CO., LTDXIHU INDUSTRIAL PARK, SANDUN, HANGZHOU CITY, ZHEJIANG, PROVINCE, CHINA

    Thg following sample(s) was/were submitted and identifed on beharf of the dients as : LEAD-FREE soLDERWIRE

    SGS Job No. :Part No. (P/N) :Composition :Date of Sample Received :Testing Period :Te6t Requested :

    Test Method :

    Test Results :Conclusion :

    sP12-028285 - SHYTWl02 (692s39-002)

    Sn2.0CuRE21 9ep 2012

    21 Sep 2012 - 25 Sep 2012Selected test(s) as requested by dient.Please refer to next page(s).

    Please ref€r to ne\4 page(s).

    Based on the performed tests on submitted samples, lhe results of Lead,Mercury, Cadmium, Hexavalent cfiromium, polybrominated biphenyls (pBB),Polybrominated diphenylethe6 (PBDE) compty with the timib as set by RoHSDireclive 2011/6yEU Annex ll; recasting 2OO2|95/EC.

    k'{l efir C.nddd.l6.rno odd- osLd, w.r.l'lr 6Mnd kt n lle u! a.Ddr'rE iq Eldimo o.uffi . w*dh,|od ..d..llfu.h-.Aldfiriirmr;iitrffia

    !l|dn. rry ndr..rttr' rtr'eddr d*dihndofidd

    Signed for and on b€half ofscs-cgTc Ltd.

    ,z?r"'-Fan Jinqjie, JJApproved Sign€tory

    rhb d@Dnr b rFr.c |r nr

    . t4. rn corulrr * d..qrb ri.blFondnnr

    ry bh rmpr.(r, rnbd .

    mh|trllltflunarl&i'.9ilob 2o@qfl'I|.*f,61'|r|db+3*ll fi:M

    tn€Fa)filG60lEEiE-ArOSI9 *n.nrslcdnrllj{E-ar)6140,,0a tt{fi-21l6ao@ .tdir&lilcn

    Man!6r or rh€ sqs olo!! (scs sA)

  • Test Report No. SHAEC1216714750 Date: 25 Sep 201 2 Page 2 of 5Test Results :

    Test Part Desciiotion :

    Sp€oim€n llo. SGS Sampl€ lD Dcc,ipdon1 SHA12-167147.043 Sitvery wire

    RemarlG :(1) 1 mgftg= 1 PPm=0.0001%(2) IVDL = Method Detedion Limit(3) ND = Not Detected ( < l\4DL )(4) "-" = Not Regulated

    RoHS Dir€divo 201 1/85/EU

    Test l\rethod: With referenc€ to IEC 6232'1:2008(1) Determination ofCadmium by ICP-OES.(2) Determination of Lead by tCp-OES.(3) Determination of Mercury by |CP-OES.(4) Determination of Hexavalent Chromium by Spot test / Cotodmetric Method using UV-Vis.(5) Determination of PBBS / PBDES by GC-MS.

    Te6t ltem(s)

    Cadmium (Cd)

    Lead (Pb)Mercury (Hg)Hexavalenl Chromium (Cr(Vl))Sum of PBBSMonobromobiphenylDibromobiphenylTribromobiphenylTetrabrcmobiphenylPentabromobiphenyl

    HeptabromobiphenylOclabromobiphenylNonabromobiphenylDecabromobiphenylSum of PBDESMonobromodiphenyl ether

    !!!it Ud!10O mS/kS1000 mSikg1To 'nT

    1000 mdkg- mgKg

    mgKg- mgKg- mgKg- mg/Kg

    ms/Ksmg/Kgmg/KgmS/kS

    - mgKs1000 mdkS

    - meyKg

    l\4DL @32 N D2 1682 N DO Negative- N D

    5 N D5 N D5 N D5 N D5 N D5 N D5 N D5 N D5 N D5 N D- N D

    5 N D

    rn .dothr,$rLbhdtuFl

    i'drbdn'l''hcd'c'|i&dcmdr.& qi.r rdta dsn-r dnr ncr .|'ld Fdr b. hnr.dmm.rr.ddaDlhMllln.d'lddtl.'

    c!dr-/. ndhl. .rtrrhd

    h dr hi rPd Dt' cir b,h. rm, .b, hro .

    .mb.r ol rh. scs Goup {8Gs€ }

    t'inr$r$fedrdrr6nl,gEidaorr 2o@3]+l..t.t.lr6ldrl33oClstn ll:M

    lElE{S-Al6ia02563lElEls-a!ffiIg 9w.64a.mrL{6-nl6|102ra rrlr{6-?r)5ae3 .€.d't!0.tM

  • Test ReportTest ltem(s)

    Dibromodiphenyl etherTribromodiphenyl etherTetrabromodiphenyl etherPsntabromodiphenyl elherH€xabromodiphenyl etherHeptabromodiphenyl etherOctabomodiphenyl etherNonabromodiphenyl elherDecabromodiphenyl ether

    No. SHAEC1216714750 Datei 25 Sep 2012 Page 3 of 5

    Lldl udtms/Ksmg/Kgmg/rgmS/kgmg/Kgmg/Kgmg/Kgm9Kgmdkg

    upt555555555

    a3NDN DN DN DNDNDNDNDNO

    Notes :(1) The maximum permissible limit is quoted from directive 201 1/65/EU, Annex ll(2) "spottest:

    Negative = Abs€nce of Cr(Vl) coating, Positive = Presence of Cr(Vt) coating;Cfhe tested sample should be further vedfied by boiling-wateFextraction method if the spot test resultis Negative or cannot be confirmed,)o Boiling-wateFextraction:Negative = Absence of Cf(Vl) coatingPosilive = Presence of Cr(Vl) coating; the detected concenhation in boiling-water-extraclion solution isequal or greater than 0.02 mg/kg with 50 cm. sample surtac€ area.For@rosion protection coalings on metals: Infofmation on sto€ge conditions and production date ofthe tested sample is unavailable and thus results of Cr(Vl) represent status ofthe sample at the timeof testing.

    n6.hffi hft *4dntuorrbrh rrh..(.)r-rd.

    f 6illselb'b.dld$0|..dlirdtqrr @lFt.-Ll.*tr6ltl€o!l6r}| l|:a@3

    TE EFZT)tll66! IBEFA)6*$,D w6|a.MHr (a-at614qer Hj F-a)fl@l . ttdhl&s@

    M.m!.t ol rhs aGs ololp (aag sA)

  • Test ReDort No. SHAEC1216714750 Date: 25 Sep 2012 Page 4 of 5

    rn. .@md I h.!d byri.6oF / E[i-r b r. ord codl|dr oi se -.,r!!5ffi tu &mil&hFd b rm. rn c.dtu k d r.{dMrffi.

    n6.hffi 6dr bdnFdrhci,rb'brn!.h,'orc

    ATTACHMENTS

    RoHS Tesflng Ftow Chart1) Name of the person who made testing: Jan Shi^/oyo Wangr'A en Xao,cary Xuz) N€me or tne person in charge of testing: Jeff Zhang/ceorge Xu/ Linda Lir) Inese sampres w€re dissotved tota v bv ore-conditioning method according to belowflow chart. (Cr6'and PBBS/PBDES test method exctudedi

    ratUlle.|lrto tr.hrt*€rthccfar zci@33+l..ti.tiEEtufta9+sltt tt: 2r@s

    lElE(6?r)6140at63tE!Et6{l)0'tE17t m.6r€..mEtB-?)6r102r1 iL(ri-?r)A!G3 .tasr'..Cc.6

    Pb/Cd/Hg PBBs/PBDEs

    Acid digestion withmicrowave/ hotplate Nonmetallic

    matedal

    1) Alkali Fusion /DryAshing

    2) Acid to dissolve Filtration and pHadjustment

    Adding 1,5-diphenylc€rb€zide

    for colordevelopment

    Addang 1,5-diphenylcarbazide

    for colordevelopment

    A red colorindicatesthe

    pre6ence of cr6*. lfnecess€ry,confirm with

    rd.r[f,t Ddod@nFr!. Thb drsrud d!.r b.6rmdr..d *ror 6 nrr,$,l.d N.ris,.4jwr d tn.c.ffiv

    Urmllr ol |h. AgA elou! (gGS SA)

  • Test Report

    Sample photo:

    No. SHAEC1216714750 Date:25 Sep 2012 Page 5 of 5

    sHA12-167147.043

    SGS authenticate the photo on original report only

    "' End of Report "*

    tt-!,ruaYanbrrrr&id,$.'icti 2tEf3+r'rr.*Jr8ltlsae'{33|t 3L M

    tErEF.e0E @ rEtE16*r)af5rr9Hj{t-aldlML fU0SAl)64e0

    lrom!.r ol rh.8og Group (8G€S )

  • T€st Report No. SHAEC1216714738 Date: 25 Sep 201 2 Page 1 ol5

    ZHEJIANG ASIA GENERAL SOLDERING&BRAZING MATERIAL CO., LTD

    XIHU INDUSTRIAL PARK, SANDUN, HANGZHOU CIry' ZHEJIANG, PROVINCE' CHINA

    The following 6ample(s) was/were submitted and identified on behalf of the clients as : LEAD-FREE SoLDER

    WIRE

    SGS Job No. :

    Part No. (PN) :

    Compositlon :

    Date of Sampl€ Received :

    Testing Period :

    Test R€quested :

    Test Method :

    T€st Resulb :

    Condusion :

    Signed for and on b€half ofscs-csTc Ltd.

    sP12-028285 - SH

    YTW2O6

    sno.3Ag0.7ouce

    21 Sep 2012

    21 s,ep 2012 - 25 SeP 2012

    Selected test(s) as requested by client

    Please refer to next Page(s)

    Please refer to next Page(s).Baa€d on the perfomed tests on submitted samples' the results of Lead'I\rercury, Cadmium, Hexavalent chomium, Polybrorninated biphenyls (PBB)'

    Polybrominated diphenyl ethe6 (PBDE) comply with the limits as set by RoHS

    Di.ective 201 1/65/EU Annex ll; recasting 200295/EC

    /Qv''Fan Jingiie, JJApproved Signatory

    .n#ffiffiirmr r* u-ra -td *vot rmrr.t.t t*

    tirtDafi$EE|ihtltrorr zxtaoil.t.|.*f,Ertr€€.lt$l ll@3

    tErEl@llitldt6!E{ti"clt06t'9 ffior*ofrxr.c+rti el Kr(,-tt)Eaffi 1j!ltor-

    iLnlirotllt SOS Otbt4 (aGS 8A)

  • T€6t Report

    Test Results :

    Test Pert De€criotion ;

    S@rn6n No, SGS Sampl€ lD D6ctiptioi1 SHA12-167147.035 Silvery wire

    Rgmarks :(1) 1 mg/kg= I PPm=00001%(2) MDL = Method Deteclion Limit

    (3) ND = Not D€teded ( < lrDL )(4) '-' = Not Regulated

    RoHS DllBdivs 201 l/85/EU

    Test Llethod

    No. SHAEC1216714734 Date: 25 Sep 2012 Page 2 o15

    with reference to lEc 6232 1 :2008(1) Determination of cadmium by ICP-oEs.(2) Dete.mination of Lead by ICP-oEs(3) Determination of Mercrlry by ICP-OES.(4) Determination of Hexavalent Chromium by Spot test / Colorimetric l\,ethod using UV-Vis(5) Detemination of PBBS i PBoES by GC-[IS.

    Test ltem{s)

    Cadmium (Cd)

    Lead (Pb)

    Mercury fig)Hexavalent Chromium (Ci(VD)

    Sum of PBBSMonobromobiphenylDibromobiphenylTribromobiph€nylTetrabrornobiphenylPentabromobiPhenYlHe/€bromobiphenylHeptabromobiPhenylOctabromobiphenylNonabromobiPhenylDecabromobiPhenYlSum oI PBDESMonobromodiphenyl ether

    Limit UlE l\rDL

    100 mdkg 2

    1000 ms/kg 2

    1000 ms/kS 2o

    1000 mS.ftS- mS/kS 5- mdkg 5- mdkS s- mSikS 5- mdks 5- ms/kg 5- mg/kg 5- mdkS 5- msikg 5- mdks 5

    1m0 mgftS- mg/KS 5

    Ij*tffib D.r. na co{d6 *r I ffi*,Hffi !#,g;"EHT* ###f g"fff ffi Stift Ufiffiffi:ffiSffi *ff rffi #ffi*,rx*$'#'ffi *lvl*sm.1m*ts""nr*

    ND50ND

    N€gativeNDNDNDNDNDNDNDNDNDNDNDNDND

    ;;bii*hEni-.6fr d tbtk r6tr.{.)r-H

    tt-ErrlFYasft.cxd|lt.9|dlcrn zfrlr3 rd€6+1)6r.@ tElEF{lF6tlHit!-2l164@raa it{&aFl@+l -l|.*tr[lt|fte||6+l lr:2@

    lr.nD.t o1$.8Gg OrouP (8cgs )

  • Tes{ Report

    Test ltem(s)Dibromodiphenyl etherTribromodiphenyl etherTetrabromodiphenyl etherPentabromodiphenyl elherHexabromodiphenyl etherHeptabromodiphenyl etherOc-tabromodiphenyl etherNonabro.nodiphenyl etherD€cabromodiphenyl ether

    thi!

    t'ilt,b.aYrbto drchrbrd,Swaon !e3a+1

    No. SHAEC1216714738 Date: 25 Sep 2012

    UdT MDt @mdkS 5 NDmdkS 5 NDmdkS 5 NDmdkg 5 NOmS/kg 5 NDmSikS 5 NDmg/kg 5 NDmS/kS 5 NDmgkg 5 ND

    I ErE {O-Zr)OtrOO*FA)ala@!.a

    Page 3 of 5

    raEFaFffiTl|{j{l.?J)6r@

    Notes :(1) The maximum permissible limit is quoted from diredive 2011/65/EU, Annex ll(2) ospot{est:

    Negative = Absence of Cr(Vl) coating, Positive = Presence of Cr(Vl) coating;CIhe tested sample should be fudher verifed by boiling-waterextraction method if the spot test resultis Negative or cannot be confirmed.)oBoiling-wateFextraction:Negative = Ahsence of Cr(Vl) coatingPositive = Pesence of Cr(Vl) coating; the detected concentration in boiling-water-ext€ction solution isequal or greater than 0.02 mgl(q with 50 cm'z sample surtace area.For corrosion protection coatings on metals: Information on storage conditions and produclion date ofthe tested sample is unavailable and thus results of Cr(Vl) represent status of lhe sample at the timeof testing.

    M.m!.rorh.scsGtuc(acgs )

  • Test Report No. SHAEC1216714734 Date: 25 S€p 2012 Page 4 of 5

    ' l ' ;-;Ltidbd$rffi '-d6.h*lhE.,nrdri*6

    ATTACHMENTS

    RoHS Te€ting Flow Chart

    1) Name of the person who madetesting: Jan Shi/Yoyo Wang/Allen Xiao/Gary xu2i Name of the berson in charge of testing: Jeff Zhang/George Xu/ Linda Liiiiii,"i !!rir!!,i. aissoried totarry 6'y pre-condit-roningherhod accorcting to berowflow chart. (Cf

    '

    and PBBdPBDES test method excluded)

    tr

    Sample Prcparation

    Sample Measurement

    Acid digestion withmicrow€ve/ hotplate

    Concentration/Dilution of extraclion

    solution

    '1) Alkali Fusion /DryAshing

    2) Acid to dissolve

    Adding 1,sdiphenylcarbazide

    for colordevelopment

    A red colorindicatesthe

    presence of cP'.neceas€ry,confirm with

    Pbrcd,Hg PB86fPBDE8

    tilairl$gYb.rto dErloat4ltrtracnr 20(43fl..tjt.*Iqldl|6els+l a|lM

    rEtE Fzr)0tac53l+{a-a)dlqaa

    rE&&4lrsartjF.?1)6@

    $6nb.fol th.ao6 GlDlD {8oas )

  • Test Report

    Sample photo:

    No. SHAECl2'16714738 Date: 25 Sep 201 2 Page 5 of 5

    sHA12-167147.035

    SGS authenticato the photo on original report only'* End of Report ""

    (d-l!r. .Dor d6.ccil-iibhihr.ldcn.h,

    ' | l ! !a|i!!{ l |ddbd',td.lwb|||d4ded

    tLlliDl! Bftfiufition 2dEs rElE[6-eDdag6l lElfF2l!ffia *6r*.&rr{&a1}ara@a ttF+lFN .,9d'rt.l.-tr.tl.*tr6l||,|rF|6r+l ll: @3

    l|.fiDcrolm. SOS Gtu,D |SOSS ]

  • nov'TEST REPORT

    NO.:4002E11121307-2R02 Oa!aiDec15,2o11 page 1 of4

    Customer: Suzhou FuHong Electrcnic IndustfialCo, Ltd.Addrgs8: NO.89WEl DU ROAD, WANGTING TOWN, XTANGCHENG D|STR|CT, SUZHOU, CHTNAReport on th6 3ubmitted ssmple said io beSample name: Fusos copper shellllodol: /

    Material: /D$cription: /Buyea: /supplier: /

    Sa|nple recelved date: Dec.13,2011Tcatlng p€riod: Frcm Dec.13,2011 to Dec.15,2011

    T€tino Reau6tedAs specined by client, to delermine the L€ad, Cadmium, Mercrry & Hexavatent Chrcmium content in the submitted sampte inaccordance wilh Direclive 2002/95/EC (RoHS).

    Tcstind method:

    Testing llem [,leasudng inslrument MQLLead (Pb) EC 62321: 2008, seclion 9 ICP-OES 2mglkg

    cadmium (Cd) EC 62321: 2008, section I ICP€ES 2 mg/kgMercury (Hg) EC 62321r 2008, section 7 rcP-oEs 2 mg/kgChrom'um (Cr l'I) EC 62321:2008, Annex I 0.02mg,a(g'

    ILS, PLEASE REFER TOTHE FOLLOWING PAGE(S)'**'

    lsg-'0.02 mg/kg returs 10 lhe MQLofsample extEction tiquid.

    99!s!.c!i9!j-ffien tesied as specifred the submitted sample complied with the requircments of commission Decision of 18 Aug 2005amending Directive 2002l95/EC nolified lnderdocument 2005/618/EC

    ',:,"il:::i" ryf4lffH*"",",We-i hr n

    ,3ffi::::1,,44

    S}'EI{ZN€N AOV TGSTING T€CHNOlOGY CO.,L'D.KUNSHAN EiANCH Hotllne86-512-5510 8000

  • 6novNO.: 4002E11121307-2R02

    TEST REPORT

    Add the digestion solution; thevessel is heated Lrntil lhe sampl€ Add HrO, u nlil the sampl€ is clear

    F;;1.-F;;,",..;-1.-{Melal subslrat€)

    Add lhe digestion solution, clos€

    the macrowave vess€|.

    Cooling the vessel, fllleri washed and

    filled to the mark with distilled water.

    The sample is digested in the

    micrcwave oven following a specific

    decomposilion program.

    and l\rercury Content: (Praring)

    _____-l coor,ns. nrr", *""n"0 ""0 r"o | ,l o*o -ill_.;*--;-l

    I to the mark with Dtwater I I r*r.r*t | | -.- |

    STIENZH€N AOV TESIING T€CIII{OLOGY CO.,lIO,KUII9HAN BFANCH

    Hdpi/j,w.o{,6n

    Hotline86-512"s510 8oO0

    Cooling the vessel, filter washed and

    filled to the mark with distilled water.

    Remove the sample, and coollhe beaker lo rcom tempefalure,and do 1ie color reaction

    Heal 50 mL ofDlwaterin lhe

    beakerto boiling for 10 min

    Test the sample solution and lhe 0.02mg/kg standard solution by UV-VIS.

    To Detemine

  • nov.NO.: 4002E11121 307-2R02

    5. To Detemine Hexavalent Chromium- '' ',.'1re$eo ovr I r

    s.t sw-resi (M&

    TEST REPORTDate: Dec.15, 2011

    Contentln colorless and colored ctlromate coaling on

    Page 3 ol4

    metals: (Plating)

    lflhe lest resull is positive,

    the sample is considered 1o

    have hexavalenl chromium

    and the 0.02 mg/kg

    Boiling- waieF extractionprocedure shall be used to

    lfthe€ isrnterference orI rs hard to decide *terhellhe sample have the hexavalent chrcmium

    5 2 Boiling- wEter- en€ction

    Take the (5015) cm'z

    sample in the beaker.

    Srmple d93cription:

    SH!NZHEN AOV TESTING TCCTNOIqGY CO.,L}D,KUNSHAN BFANCH nHot l ine86'512^5510 8000

    Remove he sample, and cool

    lhe beaker 1o room temperature,

    and do the color reaction

    Heat 50 mlof Olwater in the

    beaker lo boiling for 10 min

    Test the sample solution and the 0.02

    mg/kg standard solution by UV-VIS.

    Copper shell subslrateLead wle Platrng 24 Copper shell Plaling

    Unil RoHS

    Limit 2-3 24"Lead (Pb) mg/Kg 1000 N.D. 2.5 40.0 N.D.Cadmium {Cd) mg/kg 100 N,D. N.D. N.D. N.D.Msrorry (Hs) mg/kg 1000 N.D, N.D, N.D. N.D.Chromium (Crvl) mg/Kg 1000 Negative Negative Negalive Negative

  • nov.TEST REPORT

    NO.r A002E11121307-2R02 Dat€iOec15,2011

    -The new RoHS di.ective 2011/65/EU, on Jul 21, 2011 come into force, on Jan. 03, 2013 the fomat imotementation. Dircctive

    2002l95/EC shall be reoealed simultaneouslv.

    Sp€cim€ns, wnicn requested to determine Lead, Cadmium and l4ercury Conlent, have been dissotved comptetety.-mg/kg=ppm

    -N.D.=not detected(

  • BEIJING HYSTIC NEW MATERIALS CO,, LTD.

    5 SHUANGYUAN ROAD, BADACHU HIGH.TECH ZONE,BEIJING,100041, cHtNA

    Test Report

    l\rodel No. :

    Date of Sample Received :Testing Period :Test Requested :

    Test Method :

    Test Results :

    Conclusion i

    O\ N6'(

    The following sample(s) was^^/ere submitted and identified on behalf of the ctients as : EpOXy ADHESTVE

    SGS Job No. : TP12-004950 - TJ

    EP6O8

    3l Mat 2012

    31 Mat 2012 - 09 Apt 2012Selecled test(s) as requested by client.

    Please refer to next page(s).

    Please refer to next page(s).

    Based on the perfomed tesb on submitted samples, the resutts of Lead,Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyts (PBB),Polybrominated diphenyl ethers (PBDE) comply with the limits as set by RoHSDirective 2011/65/EU Annex ll; recasting 2002/95/EC.

    Signed for and on behalf ofscs-csTc Ltd.

    No. TSNEC1200272601 Date: 09 Apr 2012 Page 1 of I

    r 13t2?66233000 I l|t2ri5e95?52 {r*cr !$.ohr 136 266233000 r 136-?a2546?52 e s!.c\ia@6!3@

    Aimy WangApproved Signatory

    rh!do.!n'lt6!.d5ylh.con!.iy

    ' id ! ' .drdoi r. i,.; dsr..d 't.,.h r Nift_a'rni ;iir..d h!'F''fl *

    I i is do.,m;iclnndis ro'odutad

    scsMans'6i.N6.41Th. srf Avenue rloA,Ti.nj n china 3ol4s74 E .*tlisftfi{*€6tt*S4l es6s*l Srl 300457

    Memberol rh. SGSGolp{SGS SAI

  • Te€t Report No. TSNEC1200272601 Date: 09 Apr 20 1 2 Page 2 ol8Test Results :

    Test Part Description :

    Sp€d.n€n No. SGS Ssmple lD D€6criplion1 TSN12-002726.001 ivory-white paste

    Remarks :(1) 1mg/kg= 1 ppm = 0.0001%(2) IIDL = Method Detection Limit(3) ND = Not Deteded ( < MDL )(4) "-' = 1o1 q"nu,","o

    RoHS Dirodive 201 t/66/EU

    Test Method : With reference to |EC62321:2008(1) Determination ofCadmium by tCP-OES.(2) Determination of Lead by ICP-OES.(3) Detemination of l,rercury by ICP-OES.(4) Determination of Hexavalent Chrcmium by Colo metric Method using UV-Vis(5) Detemination of PBBS / PBDES content by GC-MS.

    Test ltem(s)Cadmium (Cd)Lead (Pb)lllercury (Hg)Hexavalent Chromium (Cr(Vl))Sum of PBBSIvlonobromobiphenylDibromobiphenylTribromobiphenylTetrabromobiphenylPentabromobiphenylHexabromobiphenylHeptabromobiphenylOclabromobiphenylNonabromobiphenyl

    DecabromobiphenylSum of PBDESMonobromodiphenyl ether

    tinit Ud!100 mg/kg1000 mS/kS1000 mS/KS1000 mS/kS1000 mdks

    - mg/Kg- mg/Kg- mg/Kg- mg-fts' mgKg- mgKS- ms/Ks- mg/kg- mgKg- m9x9

    1000 ms/ks- mg/Kg

    sG s Madsioi Nc.41 .Tho slh Avenue T EoA,llan in, chiM 1l}a57s F . *lriE*fitrtte8lit641Cscs*l ffll: 300457

    MDt 0p12 N O2 N D2 N D2 N D- N D

    5 N D5 N D5 N D5 N D5 N D5 N D5 N D5 N D5 N D5 N D

    ND5 N D

    ;trvdGhFo&de,sr,E^rh.;d.i@br.^ {1d".'db.tr' bt6$n;tonl!N{h'i rh rnir t r rd r . 6i1rir h 6 do.vnld d.di'ci't6rr.nE i DaDbh" -d d e

    h,q!aoit" rc'rdn dr s.iod.d'

    I 136 2aBA80CC | 0G42529s29 f,nqc'i!9s@rI {3f2r66?8806 l1e2?26&12 s sss.f'[email protected]

    Membero, rbe SGS Group (SGS SA)

  • Test Report

    Tost ltem(s)Dibromodiphenyl elherTdbromodiphenyl elherTelrab.omodiphenyl etherPentabromodiphenyl elh€rHexabromodiphenyl etherHeptabromodiphenyl etherOctabromodiphenyl etherNonabromodiphenyl etherDecabromodiphenyl elher

    Notes :

    No. TSNEC1200272601 Date: 09 Apr 2012 Page 3 of 8

    trd!

    (1) The maximum permissibte limit is quoted from directive 2011/65/EU. Annex lt.

    Horebrpmocrrdododecane THBCDD)

    Test lvlethod : With reference to IEC 62321:2008, anatysis was p€rfomed by GC-N4S.

    udtms/Kgmg/KgmS/kSms/Ksmg/kgmg/Kgm9KSmgKsmgKs

    UlitmgKg

    MDt555555555

    @1N DN DNDNDNDNDNDNDND

    pp1N D

    T€st ltem(s)Hexabromocyclododecane (HBCDD)

    Notes :

    Test ltem(s)Dibutyl Phthalate (DBP)B€nzylbutyl Phthalate (BBP)Bis (2-elhylhexyD Phthalale (DEHP)

    Notes :

    !d! MDt 0p1% (w4,,/) 0.003 ND% (ww) 0.003 ND% (Ww) 0.003 ND

    MDI1 0

    (1) Reference Information: Diredive 201 1/6S/EU recasting RoHS directive 200?J9S/EC:Hexabromocydododec€ne (HBCDD) is considered as a priority for riskevaluation and substancerestriclion.

    Phthalatss

    Test l\Iethod: With reference to EN14372:2004, anatysis was performed by co-tvts.

    (1) Reference Infomation: Directive 2011/65/EU recasting RoHS directive 200295/EC:Bis (2-ethylhexyl) phthaiate (DEHP), Butyl benzyt phthatate (BBP) and oibutyt phthatate (DBp) areconsidered as a pdority for riskevaluation and subslance restiction.

    l 6 y h . c o f r ' m ' s b ] k l ] o t 6 . n ' d

    scsMa^tion,No.4l.Tnb 5lh Av€ns€',lEoa,Iaiti.chie 3&457 I i3t,21d5233,t0t r 196-242!2$?52+ B -XirtEi*Si'l&Etni64 r qscs^lt itat:3i1o457 r €t|2r6623!O@ jL3r2:r252!5?c .

  • Test ReportResult shown is

    No. TSNEC1200272601

    of the total weight of wet sample

    Date: 09 Apr 201 2 Page 4 of I

    r i . coh r . i y t ' oh , . . po iN rV r t

    y rubt.cr 'o {. o.i.'.r coid [oi. or s.rdrtrr @Mr,idrJ.d 'o rdnt rd

    scsMa6roi,No.4l,lh. 5n Ae.n!a1e0A,15njh,ar 6:mr57 r i+P|654806 r 1s-2)25?$2C 'w.i s95 @mFl.lliiE titlalnifr4rqscs*! fit:3s457 r t36-22r6su30m r1s-?aa9r5a52 . !oBdh.6s$m

    Menberolrh. SGSGrow ISGSSAl

  • SGS-

    1 )

    2)3)

    Test ReDort No. TSNEC1200272601 Date: 09 Apr 2012 Page 5 of 8

    ATTACHMENTS

    cd/Pb/Hg/Cf'lPBB5&PBOES Flow Chart

    Name of lhe person who made tesl ing: Aer0n Wang/Jason Li /Angel l Yao

    Name ofthe percon in charge oftest ing: Cindy Yin/Rel ZhuThsse samples wsrs dissolved tolal ly by pre-condi l ioning melhod according to

    below l low chari . (C16* and PBBS/PBDES test melhod excluded)

    ill;l,ffi;i;lii'#:;' i;;;;i'-,iiiliir ii'iiii;'";l;;n *a ro 1t:.,.trere1"l:,11e191191':ll1"l:11*:::::L:11.,1:1:":i:YlTi."ii i i; ;ii; ;'. ti;;:'ii.c"npi'ivt or..p*rurv "tid."di^, ; rn! dod@dca'mri . '#li*lr,:*r";*iitikl.*ri:ni*l:"ll*t:iim::,ttiil:r:r.""i?i"::::'ii,llii:::lligiirliii:?';"'tiiii'i:il*"'

    scsManeion.No 41,Ti6 5U Av€rueTEOA.Ianjri ChiM 3COa57

    +F.*Ffislit$*x&8tEt! 1qscs*! itia:3m45rI waa'52tflt( I t*r425294244r lst-Pr65a&[0 I]36-24?52S52t e s{sch$@s!s'm

    Sample Preparation

    Sample lVeasuremenl

    Acid digest ion wi lhmicrcwave/ holplale

    Sample solvent Adding digest ion reagent

    Heating io 9tF95'C forextractionConcentral ion/

    Di lut ion ofextract ions0iuIt0n

    ResiduBSolution Fi l t ral ion and pHadjustmenl

    1) Akali Fusion IDry Ashin g2) Acid todissolve

    Adding 1 ,5'diphenylcarbazide fo!

    coloi development

    Fb/Cd/Hg PEB'PEDE5

    Membero , lne SCS Group (SGS SA)

  • Test Report

    ATTACHMENTS

    ' l ) Name ofthe percon

    2) Nams of lhe person

    No. TSNEC1200272601 Date: 09 Apr 2012 Page 6 ofB

    HECDD Tosting Flow Chaft

    who made test ing: Marine Sunin charge oftest ingr Rex Zhu

    h'iii d*,n'n.&ij'd b i.rrs

    Liliiiiiidin'ii riirul6d t'.ry. tbi"6p.^,! -h..ts*,', t'uf,.dr rh* eon..r ei@' bo 'Jed

    scs M.Giai.No 41 ft. &n A64rEDAri.nJh,chi.a 3&457+E *afiE lE*tla lritr! | i scs*l ilfl.3045,

    I {36-2tl 65?90{C 1 r&-?4 15295eq2r {62t652&0C0 i 18&24252$?52 e s0scr\N@!os6m

    Mebberol rh6 scs Grouo (SGS SAI

    Sample cutt ing/preparation

    Sample measurement

    Solvenl exhaction

    ConcBntral iodDilut ion

  • Test Report

    ATTACHMENTS

    Phthalde Testng Floli, chaft

    1) Nams of lhe pelson who made lest ingi Maina Sun

    2) Name ofthe person in charge oftesl ing: Rsx Zhu

    i,ffi{{ftf#,fii#jja!:i;'}'.f:rir"" lirid+s6s Ma nsion, No 41 ,Th. 5lh Av.n u. T EDA,llr.jl., ChlM 3Xr457 I l€6 2?)65:4q10 r 1!t2)25295252 slcir93@tr

    +F.iitejtfr*teEfEt64lcscs^! tl:300457 lls6'4)652$ffi I [t42529525? t sqsd'ha@'ssom

    Mbfrberoilh6 SGs 6roup {SGs 5A)

    No. TSNEC1200272601 Date: 09 Apr 2012 Page 7 of I

    Solvenl exhacl ion

    Conc entralion/Dil ution

    Fihralion

  • Test Report

    Sample photo:

    TSN12-002726.001

    SGS authenticate the photo on original repoionly

    '*. End of Report '-

    $:l:S,e*',#l+-*I*fiini,iil'*t";l*l'";*i#;fi l#;tr$#,Ii.1i;;iffi ri[l,iL"r't*xf"i,f,itii5rffii:Iitrfl{'iflrif.t*n,lf*jli;i+Ui*l'11;':r"-ff:"{'iili"iir,:,,i1ifi;'ilt-:;;t;;iJ; -;;";,'.; - "- "op-:. 91,.":9:t!"^"

    I lt6-z)65l!dn I (S-24 252S5252I ls6-a666d0@ I t*A:s2$?e 6 .Oschiia@E3d

    Mehboror $€ scs GbuP (SGS SA)

    No. TSNEC1200272601 Date: 09 Apr 20 1 2 Page 8 of 8

    scs Malior.No 4l,rno 5h aleFJ. rEDA qan 'n chrB 3m'5'

    +!.xt6e;r*iteEtt16llCscs*! {|:30q9l

  • Test Report

    BEIJING HYSTIC NEW