4
ICEBERG HIGH WALL R-410A 60Hz TROPICAL HEAT PUMP YHGE 12 to 30 ZT3CFEOR3 A complete range from 11,900 to 27,600 Btu/h

ICEBERG HIGH WALL R-410A 60Hz TROPICAL HEAT PUMP YHGE … · 2020. 8. 6. · 2 3 ICEBERG HIGH WALL R-410A 60Hz TROPICAL HEAT PUMP The YORK® line of High Wall Air Conditioners includes

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ICEBERG HIGH WALL R-410A 60Hz TROPICAL HEAT PUMP YHGE … · 2020. 8. 6. · 2 3 ICEBERG HIGH WALL R-410A 60Hz TROPICAL HEAT PUMP The YORK® line of High Wall Air Conditioners includes

ICEBERG HIGH WALL R-410A 60Hz TROPICAL HEAT PUMP

YHGE 12 to 30 ZT3CFEOR3A complete range from 11,900 to 27,600 Btu/h

Page 2: ICEBERG HIGH WALL R-410A 60Hz TROPICAL HEAT PUMP YHGE … · 2020. 8. 6. · 2 3 ICEBERG HIGH WALL R-410A 60Hz TROPICAL HEAT PUMP The YORK® line of High Wall Air Conditioners includes

2 3

ICEBERG HIGH WALL R-410A 60Hz TROPICAL HEAT PUMP

The YORK® line of High Wall Air Conditioners includes a wide range of sizes to give you more flexibility in your product offering. Each model is designed to provide comfort and efficiency, in an easy-to-operate unit and the sleek design fits a variety of spaces, whether it’s in a home or office. Models meet the highest energy efficiency ratings, so less energy is consumed without sacrificing comfort and performance. Both the condensing and indoor units are engineered for quiet operation. And comfort control settings are easily changed with the touch of a button on the remote control.

Indoor Unit

• Modern, compact design• Efficient cooling/heating• Auto restart• Long distance air flow• I feel• WIFI Control (Option)

Remote Control

• 5 operation modes• Sleep mode and on/off timers• Installation bracket included

Condensing Unit

• Convenient installation• Easy maintenance• Valve protection cover

24K-30K12K-18K

12K-24K

30K

Page 3: ICEBERG HIGH WALL R-410A 60Hz TROPICAL HEAT PUMP YHGE … · 2020. 8. 6. · 2 3 ICEBERG HIGH WALL R-410A 60Hz TROPICAL HEAT PUMP The YORK® line of High Wall Air Conditioners includes

2 3

ICEBERG HIGH WALL R-410A 60Hz TROPICAL HEAT PUMP

Features and Benefits

Multi-Speed FanMulti-speed fan helps satisfy various airflow requirements.

Auto RestartUnit is automatically returned to previous operating conditions after a power outage, for simplified operation.

3-Minute ProtectionA 3-minute delay before the compressor will restart helps avoid compressor damage and work time.

I FeelA temperature sensor embedded in the remote control helps ensure accurate air temperature around the user and not just around the indoor unit, providing maximum comfort.

Self DiagnosisClearly displayed failure codes allow for quicker troubleshooting and easier maintenance.

24-Hour TimerAllows programmed start times up to 24 hours in advance for flexible and more convenient operation.

Inner Groove Copper Tube

Inner groove copper tubing allows more refrigerant to pass through, improving heat exchange by 30 to 50% when compared to traditional copper tubing, and lowering power consumption while keeping output capacity at the same level.

R-410AEnvironmentally-friendly refrigerant cools and heats more efficiently without destroying the ozone layer.

High Ambient Cooling at 61°CThe Ac will run in cooling mode when outdoor temperature is up to 61°C to meet special user-requested applications.

WIFI Control (Option)Controls air conditioner with Smart phone or tablet through Internet.

Page 4: ICEBERG HIGH WALL R-410A 60Hz TROPICAL HEAT PUMP YHGE … · 2020. 8. 6. · 2 3 ICEBERG HIGH WALL R-410A 60Hz TROPICAL HEAT PUMP The YORK® line of High Wall Air Conditioners includes

Nominal testing conditions @T1:Cooling - Indoor 80.6°F DB / 66.2°F WB (27°C DB / 19°C WB) & Outdoor 95°F DB / 75.2°F WB (35°C DB / 24°C WB)Heating - Indoor 68°F DB / 59°F WB (20°C DB / 15°C WB) & Outdoor 44.6°F DB / 42.8°F WB (7°C DB / 6°C WB)Nominal testing conditions @T3:Cooling - Indoor 80.6°F DB / 66.2°F WB (27°C DB / 19°C WB) & Outdoor 114.8°F DB / 75.2°F WB (46°C DB / 24°C WB)

Specification

Johnson Controls, the Johnson Controls logo, YORK are registered trademarks of Johnson Controls, Inc in the United States of America and other countries. Other

trademarks used herein may be trademarks or registered trademarks of other companies.

FOR MORE INFORMATION CONTACT JOHNSONCONTROLS.COM

© 2018 Johnson Controls, Inc, P.O. Box 423, Milwaukee, WI 53201, All rights reserved worldwide.

York Set Model YHGE12ZT3CFEOR3 YHGE18ZT3CFEOR3 YHGE24ZT3CFEOR3 YHGE30ZT3CFEOR3York Outdoor Model YHGE12YT3CFEO-3 YHGE18YT3CFEO-3 YHGE24YT3CFEO-3 YHGE30YT3CFEO-3York Indoor Model YHGE12XT3CFE-R3 YHGE18XT3CFE-R3 YHGE24XT3CFE-R3 YHGE30XT3CFE-R3

Power supply Ph-V-Hz 1Ph - 220~230V - 60Hz

Cooling@T1

Capacity Btu/h 11,900 18,000 23,000 27,600 Power input W 975 1,475 1,870 2,230 Rated current A 4.3 6.5 8.4 10.5 EER Btu/h·W 12.20 12.20 12.30 12.30

Cooling@T3

Capacity Btu/h 10,000 15,000 19,800 24,400 Power input W 1,150 1,725 2,275 2,805 Rated current A 5.1 7.7 10.2 12.5EER Btu/h·W 8.70 8.7 8.7 8.75

Heating

Capacity Btu/h 11,942 17,742 23,202 27,637 Power input W 945 1,445 1,890 2,130 Rated current A 4.2 6.4 8.5 9.5COP Btu/h·W 12.63 12.28 12.28 12.97

Max. input consumption W 1,550 2,300 3,000 3,400 Max. current A 8.3 11.9 16.0 17.5

Compressor

Type ROTARY ROTARY ROTARY ROTARYPower input W 970 1,505 1,965 2,225 Rated current (RLA) A 4.75 6.55 8.80 9.90 Locked rotor Amp (LRA) A 27 36 46 50Capacitor μF 35 35 45 55Refrigerant oil/oil charge ml ESTER OIL VG74 / 350 HAF6801 / 480 α68HES-H / 570 α68HES-H / 570

Indoor fan motor

Power input W 30 70 45 116Capacitor μF 1.5 2 NA (DC Motor) 3Speed (Hi/Mi/Lo) rpm 1,100/950/800 1,100/950/800 1,160/1,000/850 1,280/1,060/860

Indoor air flow (Hi/Mi/Lo) m3/h 660/570/480 1,050/900/750 1,200/1,100/900 1,500/1,250/1,050Indoor noise level (Hi/Mi/Lo) dB(A) 39/37/34 43/40/38 46/43/39 51/45/42

Indoor unitDimension (WxHxD) mm 850×270×202 960×315×230 1,131×315×230 1,280×367×266Packing (WxHxD) mm 900x335x260 1,022×380×302 1,220×400×310 1,385×435×325Net/Gross weight kg 8.5/12.0 12.5/15.5 14.5/19.0 19.5/23.0

Outdoor fan motor

Power input W 65.5 130.0 166.0 187.4Capacitor μF 3 4 4 4Speed rpm 850 840 780 900

Outdoor air flow m3/h 2,000 2,500 3,200 3,400 Outdoor noise level dB(A) 52 55 59 60

Outdoor unitDimension (WxHxD) mm 780×540×260 860×650×310 885×795×366 885×795×366Packing (WxHxD) mm 910×600×360 995×730×445 1050×910×500 1050×910×500Net/Gross weight kg 33/35 45/50 54/63 58/66

Refrigerant type/Charge g R-410A/1,060 R-410A/1,400 R-410A/1,810 R-410A/2,400Refrigerant additional charge g/m 20 x (Length-5) 20 x (Length-5) 30 x (Length-5) 40 x (Length-5)

Refrigerant piping

Liquid side/ Gas side mm Ø6.35/Ø12.7 Ø6.35/Ø12.7 Ø6.35/Ø12.7 Ø9.52/Ø15.88Max. refrigerant pipe length m 15 15 15 15Max. difference in level m 5 5 5 5

Indoor setting temperature range °C 16~30 16~30 16~30 16~30Ambient operation temperature (Cooling/Heating) °C 21~61/-10~24 21~61/-10~24 21~61/-10~24 21~61/-10~24Application area (Cooling Standard) m2 12~24 18~28 26~32 33~50Qty’per 20’ /40’ /40' HQ Set 103/220/264 67/142/160    44/92/114 42/88/106