ICASS

Embed Size (px)

Citation preview

  • 7/28/2019 ICASS

    1/26

    I-CASS Door Access System

    THE LEADING INNOVATOR OF SECURITY

    SYSTEM

  • 7/28/2019 ICASS

    2/26

    Table Of Content

    1. Introduction to I-CASS.

    2. Comparison with K-series.

    3. System Component.4. System configuration.

    5. System Technology.

    6. I-Cass Features.7. Technical Specification.

    8. Precaution & Maintenance.

  • 7/28/2019 ICASS

    3/26

    Sys tem Introduct ion (1)

    Max.32 doors access control system.

    Categorized into 2/4/8/12/16/24/32 doors version.

    Combination of existing door access system, time attendance

    system, and alarm monitoring system.

    T-series : Multi-door interlocking features

    K-series : Auxiliary Output relay based on defined

    transaction.

    FEP : Supervised alarm input points.

  • 7/28/2019 ICASS

    4/26

    Sys tem Introduct ion (2)

    Bring in wireless messaging technology.

    Short message service among very doors.

    Huge user and transaction storage capacity.

    High speed processing and respond time.

    Interactive blue light graphic LCD display

    Emergency over ride key( Electronic Key).

    Long reading range for proximity technology.

    Ready for mifare and wiegand 26/32bits.

    Integrated with S-series, K-series, T-series, Commando,Centurion and FEP alarm monitoring system design concept.

  • 7/28/2019 ICASS

    5/26

    1. People choose I-CASS for its flexibility usage in securityaccess control and other relevant application such as:

    1.Multi-door anti-pass back that handling max.32 doorsoperation.

    2.Multi-door interlocking features that only allow one door togrant access at a time.

    3.Guard Tour application that enabling patrol guard performchecking duty.

    4.Ethernet and GSM ready for internal and external

    communication.5.Alarm break in protection.

    6.Fire alarm emergency exist.

    Sys tem Introduct ion (3)

  • 7/28/2019 ICASS

    6/26

    Sys tem Introduct ion (4)

    Dual card entry mode and access counter mode for restricted

    access area.

    CCTV and building automation integration.

    125Khz and 13.56MHz proximity technology interfacing.

    I-CASS is designed to meet customer application including

    Door access control Guard tour patrol

    Time Attendance

    Alarm monitoring

    Car Parking control Building automation

    Fire alarm panel integration

    CCTV integration

    SmartCard based solution

  • 7/28/2019 ICASS

    7/26

    How secu ri ty hand led in I-CASS?

    System wiring design

    Electronic key design

    Communication data protection

    Emergency event or alert Low power and main fail power detection

    Communication break down protection

    Watch dog for safe guard

  • 7/28/2019 ICASS

    8/26

    Benef i t of using I-CASS

    To have more card user capacity in the system.

    To have a high speed and fast processing time for everyoperation.

    To have a large door capacity controlled under one

    controller. To have a alarm monitoring features at every door.

    To have a guard tour features at every door.

    To have SMS messaging service among door reader.

    To have variety choice of operation mode at every door.

    To have interactive graphic display on every door reader.

    To have emergency over ride system

    To have Ethernet ready capability

  • 7/28/2019 ICASS

    9/26

    Compar ison w ith exist ing contro l ler (1)

    Feature/Spec. K-series I-CASSInterlocking No 5 door per group

    (100 group)

    Anti-pass back Available among max. 8

    doors

    Available among

    Max.32 doors

    Dual card access No Available

    (100 match code)

    Access Counter No Available on every

    door setting

    Emergency Keyoverride Tabular key lock Electronic key with 4digits password.

    Display unit Normal dot matrix

    LCD

    Graphic LCD with

    blue backlit

  • 7/28/2019 ICASS

    10/26

    Compar ison w ith exist ing contro l ler (2)

    Features/Spec. K-series I-CASSEthernet No On board Ready

    GSM SMS No Ready

    Alarm monitoring Based on TTL input on

    every controller only

    2 supervised sensor

    points on every door

    Fire alarm No Fire alarm for

    emergency door

    release

    Guard Tour No Available on every

    door ready aschecking terminal.

    Auxiliary Output Available Available

  • 7/28/2019 ICASS

    11/26

    Compar ison w ith exist ing contro l ler (3)

    Feature/Spec. K-series I-CASS

    Speed 8Hz 24MHz

    User storage 5,000 users 20,000 users

    Transaction storage 2,500 50,000 users

    Door connection Max. 8 doors Max. 32 doors

    Processor 8 bits MCU 16 bits MCU

    RAM 128K Byte 2M byte

  • 7/28/2019 ICASS

    12/26

    Compar ison w ith exist ing contro l ler (4)

    Feature/Spec. K-series I-CASSShort Messaging

    Service

    No Available among door

    readers

    Door release time zone No Available on every

    door setting

    Lock out mode No Available on everydoor setting

    Emergency duress

    alarm

    Available Available

    General purpose relay

    output

    No Available on controller

    Software 32bits SmartGuard

    series software

    32bits SmartGuard I-

    CASS software

  • 7/28/2019 ICASS

    13/26

    Level of Changes

    2Mhz

    6Mhz

    1024KB

    128KB

    3

    8

    19200bps

    9600bps

    32

    16

    60% more

    40%

    Bus

    Frequency

    Onboard

    RAM

    UART

    SizeComm.

    Speed

    Door

    Connection

    Over all

    Features

    Existing System

    I-CASS System

    Comparison with Castle-S/K/T&Commando System

  • 7/28/2019 ICASS

    14/26

    System Component(1)

    I-CASS controller SmartBox (Door Interface Unit)

    Door Reader

    Electronic Key

    Power Supply

    PC interface (PCI)

    SmartGuard I-CASS v5.6

    Used as real time processing unit for all door event and alarm.

    As card user databases storage.

    As log transactions storage.

    Used for all the user setting.

    Responsible for all the communication bus polling.

  • 7/28/2019 ICASS

    15/26

    System Component(2)

    SmartBox -Door Interface Unit Used to control the electronic door lock device, door contact

    and lock release button.

    Used as reader interface communication gateway to

    controller. Perform basic door controlling function during system

    controller breakdown.

  • 7/28/2019 ICASS

    16/26

    System Component(3)

    I-CASS Reader Interface Act as reader interface for proximity reader.

    Mifare serial number interfacing.

    Wiegand 26bits interfacing.

    Keypad and LCD interfacing. Perform card number conversion.

    Display informative message.

    PIN generator

    Alarm arming and disarming interface panel

  • 7/28/2019 ICASS

    17/26

    System Component(4)

    Electron ic Key Connected to reader interface board

    Used during emergency breakdown to over-ride the door

    lock.

    Security key is stored with a standard encryption technique. 10 digits key with suitable password to release door lock.

  • 7/28/2019 ICASS

    18/26

    System Component(5)

    PC Interface Unit (PCI) Used as a gateway for controller uplink and PC

    communication port.

    Used as a signal converter for RS232 to RS485

    communication. Act as a software security key for software version

    determination.

  • 7/28/2019 ICASS

    19/26

    System Component(6)

    SmartGuardICASS v5.6 32bits PC software.

    Act as a interface software for data or user setting

    downloading machine.

    Act as log transaction uploading software for data reporting

    purpose.

    Time attendance report generation.

  • 7/28/2019 ICASS

    20/26

    System Configuration(1)

    RS 485

    RS 232

    In Reader

    Out

    Reader

    PC Interface

    Door

    Interface

    (2)

    Door

    Interface

    (4)

    Push Button

    Door

    Interface

    (5)

    I-Cass Software

    RS 485

    BUS 4

    BUS 3

    BUS 2

    BUS 1

    I-CASS

    Controller PC I

    RS 232

    Maximum 8 doors (expandable)

    Door

    Interface

    (3)

    E-Key

    E-Key

    Lock System

    Magnetic

    Sensor

    2 Wires

    Door

    Interface

    (1)

    I C F t

  • 7/28/2019 ICASS

    21/26

    I-Cass Featu res

    Polycarbonate Keypad E - Key

    LCD ScreenABS Casing

    Proximity Technology

    Press Alarm

    Alarm Systems

    Networking

    SMS

    Guard Tour

    Time Attendance

  • 7/28/2019 ICASS

    22/26

    Features High l igh ted (1)

    Enable Short Message Service (SMS) Inbound System

    Outbound System

    Storage Capacity:

    100 users with 50 characters each user.

    Doors forced open

    or burglaryOwner

    SMS

    Preset greetings or

    short messagesEmployees

    SMS

  • 7/28/2019 ICASS

    23/26

    Features High l igh ted (2)

    Guard Tour Feature

    Time set : 20 minsTime set : 10 mins

    Main Back Off

    Door 1 Door 2 Door 3

    1. Configuration

    Back

    Time set : 20 minsTime set : 10 mins

    Main Off

    Door 1Door 3oor 2Beep

    2. He/She did not proceed to Door 2

    3. He/She did not proceed to Door 3

    Time set : 20 minsTime set : 10 mins

    Main Back Off

    Door 1 Door 2 Door 3Beep

    F t Hi h l i h t d (3)

  • 7/28/2019 ICASS

    24/26

    Features High l igh ted (3)

    Controller storage capacity : Standard 20,000 users.

    Expandable to 100,000 users

    Event Transaction Storage Capacity:

    Maximum 30,000 events Multi door Anti-pass back.

    Multi door Interlocking

    On board alarm input and output point.

    Dual Card Mode.

    F t Hi h l i h t d (4)

  • 7/28/2019 ICASS

    25/26

    Features High l igh ted (4)

    Access Counter. Time Zone Control Door Release Button

    2 Holiday Groups @ 50 settings per group.

    Software Configurable to general purpose relay output.

    Enable to Interface with CIA88 additional alarm input or output

    point. Maximum 32 doors linkage per controller.

    Keypad arming on every door.

    Controller backup.

    Electronic Key (E-Key) for emergency door release.

    Support K series feature. On board Ethernet.

    Graphic LCD.

    Th E d

  • 7/28/2019 ICASS

    26/26

    ~ The End ~

    ~ Thank you ~

    Visit our website:www.castle.com.my

    for more information.

    http://www.castle.com.my/http://www.castle.com.my/