35
© 2012 IBM Corpora.on IBM Storwize V7000 Unified Overview IBM Systems Storage

IBM Storwize V7000U-Overview

Embed Size (px)

Citation preview

Page 1: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on  

IBM  Storwize  V7000  Unified    Overview  

IBM  Systems  Storage  

Page 2: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Agenda  

§  Overview    §  Architecture  &  Concepts  §  Hardware  &  Components  §  Cabling  §  SoDware  &  Features  overview  §  Ac.ve  Cloud  Engine  §  Planning  &  Implementa.on  §  Online  code  upgrade  §  Security  &  Authen.ca.on  §  An.-­‐Virus  support  §  Backup  &  Recovery  (Snapshot,  NDMP  &  Tivoli  Storage  Manager)  §  Hierarchical  Storage  Manager  §  Asynchronous  Remote  Replica.on  §  File  Clone  §  WAN  caching  (Statement  Of  Direc.on)  

2  Many thanks to Jim Kelly, Justin Heather & Sandy Leadbeater for their suggestions, comments and corrections

This  presenta=on  is  focused  on  Storwize  V7000  Unified.  To  find  more  informa=on  and  details  on  Storwize  V7000,  please  check  this  slide  deck:    

hTp://caTail.boulder.ibm.com/caTail/?source=v#[email protected]/files/EB77F620BCAF3DDA9C7C458F093F23B6  

Page 3: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on  

3  

IBM Active Cloud

Engine™

File Support

Easy Tier

RAID

Innovative GUI

SAN

Virtualization

Snapshots

One  Year  Later…  Technology  Integra=on  Con=nues  Storwize  V7000  Unified  Storage  

Leveraging  the  best  of  IBM  storage  technologies  in  a  midrange  disk  system  

Clustered Systems

Page 4: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   What’s  different?  

§  Ac.ve/Ac.ve  Unified  Namespace  across  all  file  modules  §  IBM  Ac.ve  Cloud  Engine™  technology  delivers  automated  storage  efficiency  capabili.es  –  True  policy-­‐based  management  of  files  –  With  user-­‐defined  policies!  

§  Based  on  highly  successful  Storwize  V7000  block  storage  system  §  Fully  integrated  user  interface  for  block  and  file  data  simplifies  management  

–  Not  a  “unified”  launcher  for  two  different  interfaces  §  Simple  USB  key  based  ini.al  setup  

–  Extends  successful  Storwize  V7000  approach  §  Built-­‐in  IBM  Tivoli  Storage  Manager  client  simplifies  

–  backup  to  TSM  server  –  and  Hierarchical  Storage  Management  to  tape  or  virtual  tape  library  with  dedu-­‐plica.on  –  System  also  supports  NDMP  for  third-­‐party  backup  clients  

4  

Page 5: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on  

OVERVIEW  

5  

Page 6: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on  

§  Network  File  Serving  –  NFS  v2/v3,  CIFS,  HTTP,  FTP  &  SCP  –  Clustered  parallel  file  system  –  Quotas  Management  ●  User,  group  and  fileset  level  quotas  ●  SoD  limits,  hard  limits,  grace  periods  

§  Block  Access  –  FCP,  FCoE  &  iSCSI  –  Disk  Storage  Virtualisa.on  Engine  

§  Scalability  and  Performance  –  2  file  modules    –  Up  to  960  hard  disk  drives  +  external  virtualisa.on  –  Directly  aTached  to  Storwize  V7000*  

§  Informa.on  Lifecycle  Management  –  Policy  driven  placement,  movement,  migra.on  &  

dele.on  of  files  –  Storage  .ering  (Disk-­‐to-­‐Disk-­‐to-­‐Tape)  –  Integrated  HSM  agent  to  migrate  inac.ve  files  to  

tape  or  Deduplica.on  VTL  

Overview  

6  

Clustered  parallel  file  system  Active Cloud Engine

CIFS   NFS   HTTPS   FTP  

Storage  Virtualisa=on  Engine  iSCSI  FCP  

SCP   NDMP  

NIS/ AD

NFS

HTTPS

CIFS

DFS IP  layer  

iSCSI

SAN  layer  

FCP

Shared  Integrated  Disk  

Storage  Pools  

IBM  Storwize  V7000U  

(*)  to  the  first  IO  group,  clustering  of  Storwize  V7000  mul.ple  control  enclosures  s.ll  requires    FCP  and/or  FCoE  connec.vity  

Page 7: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Overview  (cont.)  

§  Data  Protec.on  &  Security  –  File  Access  Protocols  ●  Up  to  256  snapshots  per  file  system  and/or  filesets  ●  Asynchronous  IP  Remote  replica.on  for  file  access  ●  Integrated  TSM  6.2  Backup/Archive  client  or  NDMP  ●  “Scan  on  access”  &  “scan  on  demand”  An.virus  

–  Block  Access  Protocols  ●  Point-­‐In-­‐Time  Copy  (FlashCopy/snapshot)  ●  Virtual  Disk  Mirroring  ●  Sync.  &  Async.  Remote  Replica.on  for  block  access  ●  FlashCopy  Manager  for  Windows,  VMware,  Linux,  AIX,  Solaris  &  HP-­‐UX  ●  VMware  Site  Recovery  Manager  

§  Centralized  Management  &  Administra.on  –  GUI  &  CLI  –  Centralized  alert  &  event  log  –  Event  no.fica.ons  via  email  or  SNMP  –  Performance  Monitoring  

§  RAS  –  Centralized  monitoring  of  en.re  system  via  System  Health  Center  –  Call  home  and  remote  service  features  –  Fully  redundant  capability  in  all  components  for  High  Availability  

7  

Page 8: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   SoZware  &  Hardware  Components  

8  

CIFS   NFS   HTTPS   FTP   SCP   NDMP  Cluster  Manager  

Clustered  Trivial  Database  (CTDB)  

File  Access  Protocols  

Hardware  Servers:    IBM  System  x  3650M3  (x2)  Storage:    Storwize  V7000    

Base  Opera=ng  System  RedHat  Enterprise  Linux  6  (64bit)  

WAN  caching  Panache  

HSM  HSM  agent  

Backup  &  Recovery  TSM  client  

Security  

Disaster  Recovery  Remote  Replica.on  

Parallel  File  System  &  

Ac=ve  Cloud  Engine  IBM  GPFS  

An=-­‐Virus  Scan  GUI  (web)  &  CLI  Management  Interfaces  

Monitoring  agents  

AD/LDAP/NIS  server  

TSM  server  

TSM  server  

AV  server  

Remote  Storwize  V7000U  

Storwize  V7000U  Admins  

Call  home  IBM  Support  

Backup  &  Migra=on  Protocol  

• Symantec  Netbackup  • Legato  Networker  • CommVaultSampana  

• Symantec  • McAfee  

Rapid  Data  Recovery  Snapshots  

ILM  Remote  Storwize  

V7000U  

Page 9: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Understanding  the  IO  stack  

       

Server  

Client/Server   Server          

       

       

Block  Access          

“Som

e  form

 of”  Unifie

d  Storage    A  LUN  =  a  file  

In  the  File  System          

Na=ve  File  Access      

Network  Ab

ache

d  Storage  File  System      

Logical  Volume      

Volume/Disk  Group      

Na=ve  Block  Access  

LUN/Volume  

Disk  Sub

system

 

Storage  Pool/Aggregate  

RAID  Array  

Disk  Subsystem/Appliance  Controller  

Device/RAID  Adapters/Controller  (With  or  without  ASIC  &  CPU)  

Disk  Drawers  

Disk  Drives  

9  

NetApp  &  

IBM  Nseries

WAFL

FCP  &  iSCSI  

Na=

ve  Block  Access  NFS  &  CIFS  

Na=

ve  File  Access  

Server

Filer  presen=ng  a  LUN  on  top  of  his  File  System  

Via  FCP  of  iSCSI  FCP  &  iSCSI  

Block  Ac

cess  

File  Access  

File  System  

Logical  Volume  

Volume/Disk  Group  

File  Access  

File  System  

Logical  Volume  

Volume/Disk  Group  

Each layer adds latency... Why emulating FCP & iSCSI here?

... When you could be doing it natively several milliseconds earlier? Directly from here

Page 10: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on  

ARCHITECTURE  &  CONCEPTS  

11  

Page 11: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Storwize  V7000  Unified  Architecture  

External  Local  Area  Network  (1GbE  &  10GbE)  

Each  File  Module  has  the  Interface,  Storage  &  Management  role  func=ons  Installed  &  Ac=vated  

(*)  only  the  management  role  func.on  is  ac.ve  on  1  File  Module  and  Standby  on  the  other  File  Module                All  Interface  &  Storage  role  func.ons  are  ac.ve  at  the  same  .me  on  both  File  Modules  

241

System Storage

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

File  Module  

Storage  Module  

File  Module  

Global  Name  Space  

Single  Management  Interface  

To  manage  both  file  &  block  access  

12  

Ac=ve  Tiering  

1 2

3 4

Storwize V7000 UnifiedManagement  role  Ac.ve*   Storage  role  

Interface  role  1 2

3 4

Storwize V7000 Unified Management  role  Standby*  Storage  role  

Interface  role  

No  Single  Point  Of  Failure  

Page 12: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on  

13  

Storwize V7000 Storage module (2076-1/3xx)

Control Enclosure

Architecture  

Storwize V7000 Unified File module (2073)

Storwize V7000 Unified File module (2073)

Storwize V7000 Storage module (2076-2xx) 0-4 Expansion Enclosure(s)

Storwize V7000 Storage module (2076-2xx) 0-5 Expansion Enclosure(s)

SAS  2  x  4  x  6Gbps  

SAS  2  x  4  x  6Gbps  

Point-­‐to-­‐point  FCP  2  x  8Gbps  

Point-­‐to-­‐Point  FCP  2  x  8Gbps  

iSCSI  4  x  10GbE  

 

iSCSI  &  

Management  4  x  1GbE  

FCP  4  x  8Gbps  

2  x  10GbE  

2  x  1GbE  

Management,  NFS,  CIFS,  HTTPS,  FTP,  SCP,  NDMP,  remote  replica=on  …  

2  x  10GbE  

2  x  1GbE  

Management,  NFS,  CIFS,  HTTPS,  FTP,  SCP,  NDMP,  remote  replica=on  …  

Na=ve  block  Access  File  Access   File  Access  

Each  File  Module  has  a  direct  FC  connec.on  to  each    Controller  

in  a  Storage  Module  

Page 13: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Terminology  

§  A  File  is  made  up  of  metadata  and  data  

§  A  Fileset  is  a  logical  sub-­‐tree  of  a  file  system  –  Provides  more  granularity,  flexibility  and  manageability  for  features  

such  as  Quota  management,  Snapshots,  Policies,    etc.  –  In  many  respects  behaves  like  an  independent  file  system  

§  A  File  System  is  created  using  Network  Shared  Disk  (a  LUN)  from  1  or  more  storage  pools  

§  A  Storage  pool  is  a  group  of  NSDs  within  a  file  system  

§  A  Network  Shared  Disk  (NSD)  a  Logical  Unit  Number  (LUN)  assigned  to  a  number  of  File  Modules  

14  

Page 14: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Storage  Pools  

§  Storage  pools  are  a  collec.on  of  resources  allowing  you  to  group  mul.ple  Network  Shared    Disks  (NSD)  &  mul.ple  storage  subsystems  into  a  single  file  system  

§  Storage  pools  allow  you  to  perform  complex  opera.ons  such  as  moving,  mirroring,  or  dele.ng  files  across  mul.ple  storage  devices,  providing  storage  virtualiza.on  and  a  single  management  context  

§  Storage  pools  provide  you  with  a  method  to  par..on  file  system  storage  for  considera.ons  such  as  –  Improved  price-­‐performance  by  matching  the  cost  of  storage  to  the  value  of  the  data  

–  Improved  performance  by  •  Reducing  the  conten.on  for  premium  storage  

•  Reducing  the  impact  of  slower  devices  •  Allowing  you  to  retrieve  archived  data  when  needed  

–  Improved  reliability  by  providing  for  •  Replica.on  based  on  need  •  BeTer  failure  containment  

•  Crea.on  of  new  storage  pools  as  needed  

15  

Page 15: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Storage  Pools  (cont.)  

There  are  2  types  of  storage  pools  §  Internal  Storage  Pools  

– Meant  for  managing  online  storage  resources  – Maximum  of  8  internal  storage  pools  per  file  system  

•  7  are  available  as  op.onal  user  pools  •  1  is  required  required  as  the  system  storage  pool  

–  The  Ac.ve  Cloud  Engine  assigns  file  data  to  internal  storage  pools  under  these  circumstances  •  During  file  crea.on  the  storage  pool  is  determined  by  ACE’s  the  file  placement  policy  

•  ATributes  of  the  file,  such  as  file  size  or  access  .me,  match  the  rules  of  a  policy  that  directs  the  file  to  be  migrated  to  a  different  storage  pool  

§  External  Storage  Pools  –  Intended  for  use  as  near-­‐line  storage,  archival  and/or  backup  opera.ons  – Requires  the  use  of  a  external  storage  management  applica.on  such  as  TSM  –  TSM/HSM  is  responsible  for  moving  files  on  &  off  Internal  Storage  Pools  from  GPFS  ●  Files  are  recalled  from  the  Library  Manager  upon  the  request  of  an  applica.on  opening  it  

Page 16: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Logical  Structure  of  a  File  System  

17  

§  Up  to  256  File  Systems  per  Storwize  V7000  Unified  cluster    

§  Max.  8PB  per  file  system  

§  Up  to  3,000*  filesets  per  File  System  

§  Up  to  65,536  (216)  sub-­‐directories  per  directory  

§  Up  to  263  files  per  file  system  (4,294,967,296  =  232  currently  tested)  

§  File  aTributes  include  folder  name  →  File  data  can  be  moved  to  different  storage  pools  

within  the  file  system  

File  System  

File  Sets  

Folders  (*)  Up  to  3,000  dependent  and  1,000  independent  filesets:    •  An  independent  file  set  has  a  separate  inode  space,  but  shares  physical  storage  with  the  remainder  of  the  file  system  •  A  dependent  file  set  shares  the  inode  space,  quota  limits  and  snapshot  capability  of  the  containing  independent  file  set  

Page 17: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on  

18  

Automa=c  Tiered  Storage  

§  Informa9on  Lifecycle  Management  means  Tiering  between  internal  Disk  Pools  

§  Hierarchical  Storage  Management  means  Tiering  with  external  storage  pool  (usually  tape)  with  file  pointer  leD  in  the  File  System  

§  At  mul.ple  levels  –  Storage  Pool  level  (A  group  of  LUNs)  –  Fileset  level  (Define  sub-­‐trees  of  a  File-­‐System)  

§  Using  Policies  for  rule  based  management  of  files  –  Placement  –  Migra.on  –  Dele.on  –  Exclusion  

§  Delivering  –  Scalability  è  billions  of  files  –  One  global  File-­‐System  name  space  across  independent  storage  pools  –  Hierarchical  storage  based  on  files  ●  Files  in  the  same  directory  can  be  in  different  pools  ●  Files  placed  in  storage  pools  at  create  .me  using  policies  ●  Files  moved  between  pools  via  automated  policy-­‐driven  .ered  storage  

–  Hierarchical  to  both  disk  &  tape  –  Allows  classifica.on  of  data  according  to  Service  Level  Agreements  

Tier 3

Page 18: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on  

HARDWARE  &  COMPONENTS  

19  

Page 19: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Base  Configura=on  

§  6    up  to  24  RU  solu.on  –  When  clustering  mul.ple  Storwize  V7000  storage  modules  via  a  redundant  SAN  fabric  

(via  FCP  or  FCoE),  we  are  be  able  to  scale  up  to  84  RU  (+  SAN  connec.vity)  

§  File  modules  are  provided  in  a  pair  (cluster)  §  Same  code  as  SONAS  

–  Storwize  V7000U  is  like  a  SONAS  appliance’s  storage  pod  with  Storwize  V7000  control  enclosure  as  a  back-­‐end    storage  subsystem,  and  the  interface/management  nodes  embedded  in  the  storage  nodes  

§  Each  file  module  has  all  func.ons  –  Management  node  è  a  node  is  ac.ve  while  the  other  is  

standby  

–  Interface  node  è  both  nodes  are  ac.ve  –  Storage  node  è  both  nodes  are  ac.ve  and  directly  aTached  to  Storwize  V7000  

§  Direct  redundant  LAN  connec.vity  between  both  file  modules  

20  

Page 20: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Full  Configura=on  &  Scalability  

§  Storwize  V7000  Unified  (Up  to  84  Rack  Units)  –  2  File  Modules  –  4  Storage  Modules  –  960  internal  hard  disk  drives  (SSD,  SAS  &  NL-­‐SAS)  

§  SONAS  appliance  (Up  to  17  racks)  –  30  Storage  Nodes  –  60  Interface  Nodes  –  7,200  internal  hard  disk  drives  (SAS  &  NL-­‐SAS)  

§  SONAS  gateway  (1  base  rack  +  Disk  Subsystems)  –  10  Storage  Nodes  –  8  Interface  Nodes  –  10  XIV  or  SAN  Volume  Controller  or  Storwize  V7000  

§  GPFS  –  Max.  Design  Capacity:  134,217,728  Yobibytes  (2107  Bytes)‏  –  Max.  file  size  equals  file  system  size  –  Up  to  256  file  systems  per  cluster  –  Up  to  9,223,372,036,854,780,000  files  (263)  per  file  system  –  Up  to  8192  nodes  21  

(*)  CIFS  not  supported  with  external  virtualised  capacity  

è   Far  from  using  the  full  scalability  of  either  SONAS  or  GPFS  

1 2

3 4

Storwize V7000 Unified

241

System Storage

241

System Storage

System Storage

85

41

129

System Storage

85

41

129

241

System Storage

241

System Storage

241

System Storage

241

System Storage

System Storage

85

41

129

241

System Storage

1 2

3 4

Storwize V7000 Unified

Page 21: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on  

PCI

1

2

PCI

3

4

AC

DC

AC

DC

10Gb/s

1 2

3 4

Storwize V7000 Unified

§  IBM  System  x  3650M3  (2U)  §  Quad  Core  Intel®    Xeon®  E5620  (Westmere)  

–  8  threads,  2.40  GHz,  12MB  cache,  80W  

§  72GB  DDR3  memory  

Storwize  V7000  Unified  File  Module  

23  

Management  Ethernet  (IMM)  

Unused  

Internal  IP  Network  2  x  GbE  ports  

Directly  connected  to  the  partner  File  Module  

External  IP  Network  2  x  10GbE  ports  Emulex  CNA  

External  IP  Network  2  x  GbE  ports  

Internal  SAN  2  x  8Gbps  FC  ports  QLogic  HBA  directly    connected  to  the  Storage  Module  

DVD  drive  

2  x  500GB  NL-­‐SAS  mirrored  drives  

Redundant  PSU  

Free/Unused  PCIe  slots  

Page 22: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Storwize  V7000  Unified  Storage  Module  Storwize  V7000  Enclosure  

24  

241

System Storage

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

600 GB 10K6Gb SAS

FRU 85Y5864

System Storage

85

41

129

§  Storwize  V7000  enclosure  (2U)  –  2  Storage  Bridge  Bay  (SBB)  canisters  for  the  electronics  –  Redundant  power  supplies  ●  764W  per  PSU  in  the  control  enclosures  ●  500W  per  PSU  in  the  enclosure  enclosures  

–  Internal  drive  bays  ●  Enclosure  for  12  x  3.5”  drives  (NL-­‐SAS)  

●  Enclosure  for  24  Small  Form-­‐Factor  2.5”  drives  (SSD,  SAS  &  NL-­‐SAS)  

Note:  Both  types  may  be  mixed  freely  in  the  same  subsystem.  

Page 23: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on  

§  1st  enclosure  is  configured  with  2  controller  canisters  –  Intel  Jasper  Forest  processor  (SKU  4,  EC3539,  4  cores,  8MB  cache,  2.13  GHz,  65W)  –  8  GB  DDR3  memory  

–  Internal  32GB  MLC  SSD  for  boot  and  fire-­‐hose  dump  –  Both  controller  canisters  communicate  over  an  internal  8xPCIe  Gen2  link  in  the  mid-­‐plane  

Storwize  V7000  Unified  Storage  Module  Storwize  V7000  control  canister  

25  

CAUTION

31

42

Disconnect allsupply power forcomplete isolation

Disconnect allsupply power forcomplete isolation

42

31

CAUTION

31

42

42

31

CAUTION

Disconnect allsupply power forcomplete isolation

CAUTION

Disconnect allsupply power forcomplete isolation

231

4

21

1 2

2 1

13

2412

2 14 3 2 14 3

21 4321 43

12

1 2

LNK

Tx/Rx

10Gb/s

LNK

Tx/Rx

10Gb/s

Four  2/4/8Gbps  Fibre  Channel  ports  

Two  USB2  ports  Two  1Gbps  

Ethernet  ports  

Two  6Gbps  SAS  ports  (connec.ons  to  expansions)  

Top  node  canister  

Redundant  Power  Supply  Unit  (PSU)  Note:  also  Power  Cooling    Module  (PCM)  

&  BaTery  

Op=onal  Two  10Gbps  Ethernet  ports  

Bobom  node  canister  Note:  iden.cal  to  the  top  node  

canister,  but  installed  upside  down  

Page 24: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Storwize  V7000  Unified  Storage  Module  

26  

§  Up  to  9  expansion  enclosures  may  be  aTached  to  the  control  enclosure  –  An  expansion  enclosure  is  configured  with  two  

SBOD  canisters  (Switched  Bunch  Of  Drives)  –  Each  SBOD  canister  contains  the  following  

components:  ●  36-­‐port  SAS  expander  to  aTach  the  internal  drives  

and  provide  an  enclosure  management  processor  

●  Two  4x6Gbps  mini-­‐SAS  connectors  for  chaining  enclosures  

●  Both  SBOD  canisters  communicate  via  internal  I2C  busses  in  the  enclosure  mid-­‐plane  

§  The  storage  module  could  be  clustered  via  a  redundant  SAN  fabric  to  another  3  control  enclosures  –  Each  control  enclosures  could  be  aTached  to  up  

to  9  expansion  enclosures  

§  Up  to  480  3.5”  drives,  960  SFF  drives  or  a  mixture  of  both  behind  a  Storwize  V7000  Storage  Module  

241

System Storage

241

System Storage

System Storage

85

41

129

System Storage

85

41

129

241

System Storage

241

System Storage

241

System Storage

241

System Storage

System Storage

85

41

129

241

System Storage

Page 25: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Array’s  Considera=ons  with  Storwize  V7000  Unified  

§  When  using  8+P  (RAID5),  or  8+P+Q  (RAID6)  with  Storwize  V7000  Unified  –  The  GPFS  file  system  could  use  a  block  size  of  256KiB  (default),  1MiB  or  4MiB  when  

accessing  its  file  volumes  (NSD)  on  Storwize  V7000  file  modules  

–  An  Array  on  the  internal  drives  (Hard  Disk  Drives)  of  Storwize  V7000  storage  module  would  have  a  default  stripe  unit  size  of  256KiB  at  an  array  level,  or  an  op.onal  stripe  unit  size  of  128KiB  (when  using  CLI)  

27  

RAID Topology

RAID Type

Stripe Unit

Stripe Width

Stripe Size

8+P 5 256KiB 8 2MiB 128KiB 8 1MiB

8+P+Q 6 256KiB 8 2MiB 128KiB 8 1MiB

Page 26: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on  

CABLING  

28  

Page 27: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Internal  Cabling  of  Storwize  V7000  Unified  Between  File  Modules  &  with  the  Storage  Module  

§  A  pair  of  direct  Ethernet  connec.ons  (1Gbps)  between  each  File  Modules  –  Clustering  connec.vity  

§  Each  File  module  has  a  direct  FC  (8Gbps)  connec.on  to  a  port  per  node  canister  in  the  Storage  Module  –  32Gbps  of  bandwidth  between  File  and  Storage  Modules  

§  2  FC  ports  (8Gbps)  per  node  canister  in  the  Storage  Module  can  be  used  for  external  FC  connec.on  –  Host/Server  connec.vity  for  na.ve  block  access  using  FC  protocol  (target  SCSI  port)  –  Back-­‐End  virtualised  external  storage  (ini.ator  port)  –  Remote  Replica.on  of  Volumes  (LUNs)  with  another  Storwize  V7000  Storage  Module  

29  

File    Module  1   File    Module  2  

Storage  Module  

PCI

1

2

PCI

3

4

AC

DC

AC

DC

10Gb/s

CAUTION

31

42

Disconnect allsupply power forcomplete isolation

Disconnect allsupply power forcomplete isolation

42

31

CAUTION

31

42

42

31

CAUTION

Disconnect allsupply power forcomplete isolation

CAUTION

Disconnect allsupply power forcomplete isolation

231

4

21

1 2

2 1

13

2412

2 14 3 2 14 3

21 4321 43

12

1 2

LNK

Tx/Rx

10Gb/s

LNK

Tx/Rx

10Gb/s

AC

DC

AC

DC

AC

DC

PCI

1

2

PCI

3

4

AC

DC

ATTENTIONPower supply filler is

required for system coolingRemove only when

installing 2nd power supplyAC

DC

Page 28: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   External  Cabling  of  Storwize  V7000  Unified  

§  Up  to  120Gbps  of  Front-­‐End  bandwidth  –  44  Gbps  for  File  Access  protocols,  NDMP,  management  &  IP  remote  replica.on  –  76Gbps  for  Block  Access  protocols  &  management  

31  

File    Module  1   File    Module  2   Storage  Module  

PCI

1

2

PCI

3

4

AC

DC

AC

DC10G

b/s

PCI

1

2

PCI

3

4

AC

DC

AC

DC

10Gb/s

CAUTION

31

42

Disconnect allsupply power forcomplete isolation

Disconnect allsupply power forcomplete isolation

42

31

CAUTION

31

42

42

31

CAUTION

Disconnect allsupply power forcomplete isolation

CAUTION

Disconnect allsupply power forcomplete isolation

231

4

21

1 2

2 1

13

2412

2 14 3 2 14 3

21 4321 43

12

1 2

LNK

Tx/Rx

10Gb/s

LNK

Tx/Rx

10Gb/s

External  IP  Local  Area  Network  (1GbE  &  10GbE)External  IP  Local  Area  Network  (1GbE  &  10GbE)

2x10GbE 2x10GbE2x1GbE2x1GbE 2x10GbE2x1GbE

2x10GbE2x1GbE

NFS,  CIFS,  HTTPS,  FTP,  SCPNDMP,  Management  &  Remote  Replication

44Gbps  bandwidth

iSCSI  &  Management44Gbps  bandwidth

4x8Gbps

FCP32Gbps  bandwidth

External  SAN  

Page 29: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on  

SOFTWARE  &  FEATURES  OVERVIEW  

33  

Page 30: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on  

Volume  

MDisk  Target  

Storwize  V7000  

MDisk  Source  

Storwize  V7000  Unified  Features  §  Block  Access  Protocols  

–  FCP  &  iSCSI  –  Disk  Storage  Virtualisa.on  Engine  

●  Expand  or  shrink  Volumes  on-­‐line  

●  Thin-­‐provisioned  Volumes  

●  On-­‐line  Volume  Migra.on  ●  EasyTier:  Automa.c  reloca.on  of  hot  and  cold  extents  

– Data  protec.on  &  Security  ●  Point-­‐In-­‐Time  Copy  (FlashCopy/snapshot)  

>  Full  ,  Par.al,  Space  Efficient,  Incremental,    Cascaded,    Consistency  Groups  &  Reverse  

●  Virtual  Disk  Mirroring  

●  Synchronous  &  Asynchronous  Remote  Replica.on  ●  FlashCopy  Manager  for  Windows,  VMware,  Linux,  AIX,  

Solaris  &  HP-­‐UX  

§  VMware  – vCenter  Server  management  plug-­‐in  &  VAAI  support  

– Storage  Replica.on  Adaptor  for  SRM  34  

§  Centralized  Management  &  Administra.on  – GUI  &  CLI  – Performance  Monitoring  – Centralized  alert  &  event  log  – Event  no.fica.ons  via  email,  Syslog  or  SNMP  

– Call  home  and  remote  service  features  – Authen.ca.on  service  for  Single  Sign-­‐On  &  LDAP  

§  Network  File  Serving  – NFS  v2/v3,  CIFS,  HTTP,  FTP  &  SCP  – Clustered  parallel  file  system  – Ac.ve  Cloud  Engine  

●  Policy  driven  placement,  movement,  migra.on  &  dele.on  of  files  ●  Parallel  Scan  Engine  ●  Storage  .ering  (Disk-­‐to-­‐Disk-­‐to-­‐Tape)  

●  Integrated  HSM  agent  to  migrate  inac.ve  files  to  tape  or  Dedup  VTL  ●  WAN  caching  (SoD)  

– Ac.ve  Directory,  or  LDAP  or  NIS  support  ●  Local  Authen.ca.on  Support  

– Quotas  Management  – Data  protec.on  &  Security  

●  Up  to  256  snapshots  per  file  system  ●  Asynchronous  IP  Remote  replica.on  for  file  access  ●  Integrated  TSM  6.2  Backup/Archive  client  or  NDMP  ●  “Scan  on  access”  &  “scan  on  demand”  An.virus  

Hot-­‐spots   Op=mized  performance  and  throughput  

Automa=c  Reloca=on  

SSDs   HDDs   SSDs   HDDs  

Volume  

Volume  copy  2  

Storwize  V7000  

Volume  copy  1  

Up  to  256  

Tier 3

Page 31: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Unified  Graphical  User  Interface  

35  

File  Management  Integrated  into  Naviga=on  

Storage  pools  may  be  used  for  both  block  &  file  

workloads  

File  storage  management  completely  integrated  

Page 32: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Unified  Graphical  User  Interface  

36  

Page 33: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Unified  Graphical  User  Interface  

37  

Page 34: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on   Unified  Graphical  User  Interface  

38  

Page 35: IBM Storwize V7000U-Overview

©  2012  IBM  Corpora.on  

Storage  Pools  

ACE  provides  ILM  &  HSM  tools  to  define  file  level  policies  that  determine  where  the  data  is  physically  stored  to  match  the  cost  of  your  storage  resources  to  the  value  of  your  data  regardless  of  its  placement  in  the  logical  directory  structure      

§  File  placement  policies  determine  which  storage  pool  files  are  ini.ally  placed  in  §  File  placement  rules  are  determined  by  aTributes  known  when  a  file  is  created  such  as  file  name,  

user  name,  group  name  or  the  fileset  §   Once  files  exist  in  a  file  system,  file  management  policies  allow  you  to  move,  mirror  or  delete  files  §   You  can  use  file  management  policies  to  move  data  from  one  pool  to  another  without  changing  the  

files  loca.on  in  the  directory  structure  

Ac=ve  Cloud  Engine  tools  for  ILM  &  HSM  

§  A  fileset  is  a  logical  subtree  of  the  file  system  namespace  and  provides  a  way  to  par..on  the  namespace  into  smaller,  more  manageable  units  

§   Mul.ple  levels  of  rules  can  be  applied  because  the  complete  policy  rule  set  is  evaluated  for  each  file  when  the  policy  engine  executes  

§   Storage  pools  allow  you  to  group  mul.ple  physical  storage  devices  within  a  file  system  (SSD,  SAS,  Fibre  Channel,  NL-­‐SAS,  SATA,  etc.)  

41  

ACE  

Tier 3

File  System  

Filesets