75
© 2016 IBM Corporation Philippe Hermès [email protected] Client Technical Specialist IBM Hardware System IBM Power systems

IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

Embed Size (px)

Citation preview

Page 1: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation

Philippe Hermè[email protected] Client Technical SpecialistIBM Hardware System

IBM Power systems

Page 2: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation2

✗ Nouveautés AIX 7.2 dont LKU

✗ Automatisation via PowerVC et Novalink Nouvelle vHMC

✗ Quid de la disponibilité dans l'environnement AIX ?PowerHA – LPM - SSR

30 mn

60 mn

45 mn9:15 – 9:45

11:15 – 12:00

14:15 – 15:15

Agenda

Page 3: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation3

✗ Nouveautés AIX 7.2 dont LKU

✗ Automatisation via PowerVC et Novalink Nouvelle vHMC

✗ Quid de la disponibilité dans l'environnement AIX ?PowerHA – LPM - SSR

30 mn

60 mn

45 mn9:15 – 9:45

11:15 – 12:00

14:15 – 15:15

Agenda

Page 4: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation4

● AIX Live Kernel Update (LKU)

● Integrated Server Based I/O Caching of SAN Based Data

● POWER 8 Coherent Accelerator Processor Interface (CAPI) support and CAPI attached IBM Flash System

● SR-IOV based virtual network with support for live partition mobility (The VNIC client will also be included with AIX 7.1 technology level 4.)

● NIM support for installing AIX updates and new packages over HTTP

● Enhanced Installation Control over TCP/IP Applications

● Reliable Datagram Sockets (RDS) support for RDMA over Converged Ethernet (RoCE)

● Enterprise Edition Dynamic Systems Optimizer features are included with AIX 7.2 Standard Edition

● Support for POWER7, POWER7+ and POWER8

AIX 7.2 [ les fonctionnalités majeures ]

Détaillé dans une autre session

Page 5: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation5

Imagine a

“No Reboot Required”

world

Page 6: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation6

VIOS

VSCSI/NPIV

SEA

Original LPARlpar name = orgname

Virt. ent

VSCSI/NPIV

Surrogate LPARlpar name = orgname

Virt. ent

VSCSI/NPIV

CEC

New rootvg(Alt-disk-install)Original

rootvg

HMC

Originalrootvg

Live Migration

Workload paused

Originalrootvg mirror

Original LPARlpar name = orgname_lku

Workload continues to run Workload continues to run

old_rootvg

- Utiliser le modèle de maintenance et les outils d'administrations (NIM, emgr, installp) existant

- Commencer avec le replacement du noyau AIX pour les I-fixes puis extension future pour les Sps et peut être les TLs

- L'objectif à long terme et de de fournir des mises à jour non disruptif pour tout AIX (noyau, commandes, librairies)

Les exigences du projet :

Page 7: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation7

AIX 7.2 Live Update for iFixes – Usage

Same fix

Same method of applying

New “live update” option

Prep

lvupdate.data file

hmcauth command

Command-line

geninstall -k (-p for preview)

NIM master

nim -o cust -a live_update=yes (-a install_flags=“-p”)

NIM client

nimclient -o cust -a live_update=yes (-a install_flags=“-p”)

What about? dummy.150813.epkg.Z (Q4 2015)or similar check with your IBM Support

Page 8: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation8

AIX 7.2 Live Update for iFixes – Considerations

Configuration

Virtualized I/O

Multipathing

J2 or NFS

PowerHA

lpar_id

HMC authentication

Resources

CPU & Memory

Storage

Workload

Non-cluster

“Blackout period”

Page 9: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation9

CAPP PCIe

POWER8 Processor

CAPI

Typical SSD Read/Write Flow

Flow with CAPI Flash ModelUser Space

Flash R/W CommandRead/Write

MediaUser Memory

Poll Completion

DD CallCopy or PinSource Data

Program Storage Controller

Read/Write Media

Poll / IntCompletion

Copy or UnpinResult Data

Ret. From DDCompletion

AIX 7.2 CAPI Attached Flash

Cores

Latency

IOPs

Cores

Page 10: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation10

AIX 7.2 Server Based Flash Caching

Flash Cache Engine

Workload

Flash / SSD

Server

SAN LUN LUN LUN

I/O APIs (File System, Device, etc.)

• Server caches SAN data in server attached flash• (SSD, PCI-Card, SAS attached drawer, etc.)

• Caching is transparent, no required application changes

• Potential benefits are performance (more transactions, reduced response time), and/or improved scale and efficiency of SAN infrastructure via SAN off-load

•Provides storage agnostic caching solution integrated into AIX•Supports virtualization features such as Live Partition Mobility

Page 11: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation11

SAN

Disks

VIOSLPAR

PowerVMFC

adapterSSD

adapter

SSD

VFCDD

CM

SSDCache

DD

VSCSIClient

DD

VSCSIServer

FCDD

Cache engine

hdisk

vcache

Cache mgt

hdisk

LVM

cmpartcmpool

SAN

Disks

LPAR

FCadapter

SSDadapter

SSD

FCDD

CM

SSDCache

DD

Cache engine

hdisk

vcache

Dedicated– Cache SSD uses dedicated flash LUN– Not LPM capable

Virtualized– SSD cache management pool maintained in VIOS– Client LPAR utilizes VSCSI interface to VIOS– LPM capable

PowerVM

AIX 7.2 Server Flash Cache Deployments

Page 12: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation12

AIX Flash Cache Hardware

Any Power System running AIX 7.2

Power Systemrunning AIX 7.2

Power Systemrunning AIX 7.2

SANIBM, non-IBM

SANIBM, non-IBM

Flash memory

Flash memory

Read Cache

Supported Flash memory technology• IBM FlashSystem Drawer• Power SSD in EXP24S drawer attached to

PCIe2/PCIe3 SAS RAID adapter with write cache • Power SSD in system unit run by integrated SAS

controller (write cache recommended)

Page 13: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation13

AIX Flash Cache Details

Boosts I/O performance for reads (higher throughput and lower latency)

AIX determines what is “hot data” and stores a copy in flash memory (cache)

Reads become very fast for “hot data”Writes continue to the SANCan offload congestion on connection to SAN improving write performance

Power Systemrunning AIX 7.2

Power Systemrunning AIX 7.2

SANIBM, non-IBM

SANIBM, non-IBM

Flash memory

Flash memory

Read Cache

Page 14: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation14

LVM Mirroring to Flash for Enhanced Performance (AIX 7.1 & AIX 7.2)

Application

File System

AIX LVM

LVMMirror

(lv1)

Flash Based Storage(SAN or direct attached)

PrimaryStorage

(lv1)

PreferredRead PathWrites

LVMMirroring

• New LVM mirroring policy to direct all reads to a specific mirror

• Allows LVM mirror to be used as fast copy for improved read performance

• Off-loads primary storage resources• Potentially improving the overall performance

of the storage environment

Example commands• mklv –y lv1 –c 2 –R 2 vg1 100• chlv –R 1 lv1• lslv lv1 (will show the preferred read copy)

Page 15: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation15

Other AIX Hardware Enhancements

AIX 7.2 adds RDSv3 over RoCE – adds support of the Oracle RDSv3 protocol over Mellanox Connect RoCE

adapters o #EC2M/EC2N PCIe3 2-port 10GbE NIC&RoCE SR Adapter o #EC37/EC38 PCIe3 2-port 10GbE NIC&RoCE SFP+ Copper Twinax Adaptero #EC27/EC28 PCIe2 2-port 10GbE RoCE (and NIC) Copper twinax Adaptero #EC29/EC30 PCIe2 2-port 10GbE RoCE (and NIC) SR Adaptero #EC3A/EC3B PCIe3 2-port 40GbE NIC&RoCE QSFP+ Adapter

– Instead of an IB network infrastructure, can use high-speed Ethernet connection and run RDSv3 over Oracle RAC cluster for high performance

Page 16: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation16

AIX 7.2 bos.net.tcp.client re-packaging

Goal: Reduce the need to patch unnecessary packages

– All the new split-out packages are installed by default. – User may remove the individual (split-out) packages if no other packages require them. – Once removed, those packages will not be installed/updated during future TL or SP updates. – If customers have installp packages dependent on any of the three filesets, they will need to update the pre-

req for AIX 7.2.

Page 17: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation17

AIX 7.2 Code Removal and LPP Changes

No support for POWER6, POWER5, or POWER4

Additional Code Removals from AIX 7.2– NIS+– NDAF– IBM Virtual Shared Disk (rsct.vsd)– IBM Systems Director Components; pConsole– Selected old adapters – IP over FC driver– Fcparray head driver– graPhigs– Java 5– Bos.INed– Obsolete locales– Selected performance toolbox components & eclipse2.rte, including bos.perf.gtools and

performance workbench GUI

Page 18: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation18

Removal of Trusted Computing Base

Remove “Trusted Computing Base”

Rationale:– Since AIX6.1, Trusted Execution (TE) is available and it's part of base AIX. – TE is a more powerful and enhanced mechanism that overlaps some of the TCB

functionality and provides advance security policies to better control the integrity of the system.

– Some key AIX features like WPAR is not supported with TCB

Page 19: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation19

Additional changes and enhancements Other changes

– CIFS Client – move it to the AIX Expansion Pack and provide the CIFS client with "as-is" support only.

– JFS “Classic”: Remove as an install option; function would remain in AIX 7.2 and continue to be supported

– Include DSO features in base OS (bos.aso) – no separate LPP on AIX 7.2

LPPs not supported on AIX 7.2– Fast Connect– Performance Toolbox– PowerSC Trusted Surveyor not supported on AIX 7.2 as management server

OpenSSH is being added to the Bos Install menus

HTTPD support in NIM

Page 20: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation20

NIM HTTP Option for Client ‘Pull’ Installation

Benefits of using http download access– Communication occurs over a single http port, easy firewall management– Secure transactions use digest authentication methods (TLS v1.0/1.1/1.2)– Actions are driven from the client's end (the install target), no host access required

How does it work?– The HTTP service is an embedded http service option in NIM.– The service is dynamic, binds to a well-known port, and exists only when resources are being remotely served.– IPv4 and IPv6 environments are supported

What is supported?– NIM scripting customization– Fileset install, bundle install

Limitations– No support for network boot– No support for NIM BOS installation– No support for Thin Server provisioning

Page 21: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation21

2014 +

New Hardware supported

with Virtual I/O

POWER8Virtual I/O

Evolution of AIX Hardware Support

2001

POWER4

New Release every 6 Months - Year

2007

POWER6TechnologyLevel

+ New TLevery

6 Months

2010

POWER7

+Service Pack

New SPevery

3 MonthsEase of Im

plementation

Page 22: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation22

AIX Enterprise Edition Product Structure change

Page 23: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation23

AIX 7.1 Enterprise Edition V1.1 AIX 7.1

PowerVC

PowerSC Standard Edition

AIX Dynamic System Optimizer

Cloud Manager with OpenStack for Power

IBM Tivoli Monitoring V6.3

IBM BigFix Lifecycle

AIX 7.2 Enterprise Edition V1.1 AIX 7.2

PowerVC

PowerSC Standard Edition

Cloud Manager with OpenStack for Power

IBM Tivoli Monitoring V6.3

IBM BigFix LIfecycle

Note: AIX Dynamic System Optimizer is included in AIX 7.2 Standard Edition

Note: AIX 6 Enterprise Edition will continue unchanged until withdrawal in April 2017

http://www-01.ibm.com/software/support/lifecycle/

Clients that purchased the previous AIX 7.1 Enterprise Edition 5765-G99 that have maintained SWMA do not have to upgrade to the new AIX 7.1 Enterprise Edition 5765-CD1. The entitlement to the new product is done automatically.

AIX Enterprise Edition New Offerings 4Q 2015

Page 24: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation24

BigFix Discovery and patchingA single-console management system to identify, patch, and report on multiple devices and attributes

Discover and report on every endpoint– Desktops– Laptops– Servers – Purpose-specific endpoints

e.g., ATMs and point-of-sale (POS) devices

Gain accurate, up-to-the minute visibility and continuous enforcement of patches

Manage patches to hundreds of thousands of endpoints, multiple operating systems and applications – automatically

Clients report >98% first pass patch success

Protecting 50,000 PCs, servers and ATMs in 1,800 locations with one console

SunTrust Banks

New!

Page 25: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation25

98% patch and update compliance rate on 4,000+ workstations with 50% reduced labor costs

Infirmary Health System

BigFix Continuous security configuration compliance

Accurate, real-time visibility and continuous security configuration enforcement

Continuous compliance “set and forget”• No high-risk periods

• Lower total cost

• Continued improvement

• Identify and report on any configuration drift

• BigFix was designed for Continuous Compliance!

Traditional compliance “out of synch”• High-risk and cost periods

• Manual approach causes endpoints to fall out of compliance again

Traditional versus Continuous

Time

Co

mp

lian

ce

ContinuousTraditional

RISK

New!

Page 26: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation26

BigFix Technology Level and Service Pack fix coverage for AIX

Broad patch coverage– Covers fixes for each TL and

SP fixpack– Fixes can be deployed by

either using AIX download plugin or via shared NFS directory

Flexibility and reliability in patch deployment

– AIX Interim Fix Management wizard provides a capability to install and remove interim fixes

New!

Page 27: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation27

Alternate Disk, Preview deployments, NFS Support & Rollback

Expand the new Advanced Deployment Wizard to Support additional Alt Disk features

– Replace existing alt disk cloners, create a clone / back up without running any deployments on the new clone, and deploy updates to existing alt disk images.

Add support for preview deployments of TL and SP fix packs

– Preview of deploy actions will help determine if reboot is required during deployment

Add NFS support to the old AIX Deployment wizard

– Expand AIX Deployment wizard source options to include an NFS directory without requiring files to be uploaded to the BigFix server and then transferred to target clients

Rollback AIX patches– Ability to identify and report on filesets in an applied based

on the fix pack they are associated with– Reject groups of applied filesets that are associated with a

TL / SP fix pack.– Reject groups of applied filesets that were installed on or

after a specified date.– Reject individually specified fileset(s) that are selected by

BigFix user.

New!

Page 28: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation28

AIX Enterprise Edition Includes PowerSC and BigFix

BigFix Patch For AIX

• Compliance Profiles PCI, HIPAA, NERC, DOD

• Real time Alerting for non compliance• Trusted Boot – Virtual Trusted

Platform Module• Policies to monitor TL and patch levels

with alerting• Trusted Logging

• Enterprise Console for Patching AIX plugin + support for x86 and other Unix platforms

• Patching for AIX TL and SP + iFixes+firmware

• Option to use NIM• Can use alt boot images for easy

rollback• Deployment preview to reduce errors• Supports NFS repository to speed

deployment and minimize space usage• Inventory• Reporting

New!

Page 29: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation29

AIX 6.1 Withdrawn

Withdrawn from marketing Effective April 2016

Withdrawn from standard support April 2017

Additional fee service extension planned

https://ibm.biz/directordead

Page 30: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation30

PowerVMSince 2004

KVMSince 2004

VMWARESince 1999

0

100

200

300

400

500

600

700

800

900

1000

0

95

729

0

104

900

Total CVE by hypervisor - all versions

Commons Vulnerability Exposures

2/2016

HypervisorAverage

CVE per yearsince availability

PowerVM 0

KVM 9.5

VMWare 56.3

Tota

l nu

mb

er o

f C

VE

(a

ny

vers

ion

, an

y ye

ar s

ince

dat

a av

aila

bili

ty)

on

cve

mit

re.o

rg w

ebsi

te

+9.4%

+23.4%

Page 31: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation31

OS/400 i5/OS IBMiSince 2005

AIXSince 1999

LinuxSince 1999

WindowsSince 1999

0

500

1000

1500

2000

2500

3000

3500

4000

4500

15

318

2751

3263

15

322

3135

3927

Total CVE by OS - all versions

Commons Vulnerability Exposures

2/2016

OSAverage

CVE per year since availability

OS/400 i5/osIBMi

1.3

AIX 20.1

Linux 195.9

Windows 245.4

Tota

l nu

mb

er o

f C

VE

(a

ny

vers

ion

, an

y ye

ar s

ince

dat

a av

aila

bili

ty)

on

cve

mit

re.o

rg w

ebsi

te

+1.2%

+13.9%

+20.3%

Page 32: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation32

Commons Vulnerability Exposures

2/2016

Data donwloaded from http://cve.mitre.org/cgi-bin/cvekey.cgi?keyword=xxx website

wget http://cve.mitre.org/cgi-bin/cvekey.cgi?keyword=AIXand so on, replace AIX by windows, linux, KVM, PowerVM, VMWare, IBMi, i5/OS, OS/400.

Indicates the dates when datas were downloaded from cve.mitre.org website

xx% Indicates the percentage of evolution between the two dates

Page 33: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation33

http://www-03.ibm.com/systems/power/software/aix/whitepapers/

Page 34: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation34

http://www-01.ibm.com/common/ssi/cgi-bin/ssialias?infotype=PM&subtype=RG&htmlfid=POO03022USEN

Shorter URL:-) http://ibm.biz/AIX-From-Strength-to-Strength

Page 35: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation35

Connaissez vous les IBM Champions ?

Ce n'est pas un IBMerCela peut être n'importe qui dans le monde

http://www.ibmsystemsmag.com/ Lire le n° d'avril

https://www.ibm.com/developerworks/community/blogs/ibmchampion?lang=en

2016 IBM Champions for IBM Power 34 Champions : 17 nouveaux Champions et 17 Champions reconduits.

Torbjorn Appehl Andy Lin

Balazs Babinecz Alan Marblestone

Aaron Bartell Christian Masse

Alberto C. Blanch Pete Massiello

Shawn Bodily Rob McNelly

Benoit Creau Brett Murphy

Shrirang "Ranga" Deshpande Jon Paris

Waldemar Duszyk Mike Pavlak

Anthony English Trevor Perry

Pat Fleming Steve Pitcher

Nigel Fortlage Billy Schonauer

Susan Gantner Brian Smith

David Gibbs David Tansley

Ron Gordon Paul Tuohy

Midori Hosomi Jeroen Van Lommel

Tom Huntington Dave Waddell

Terry Keene Charles Wright

Page 36: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation36

✗ Nouveautés AIX 7.2 dont LKU

✗ Automatisation via PowerVC et Novalink Nouvelle vHMC

✗ Quid de la disponibilité dans l'environnement AIX ?PowerHA – LPM - SSR

30 mn

60 mn

45 mn9:15 – 9:45

11:15 – 12:00

14:15 – 15:15

Agenda

Page 37: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation37

V1.2 octobre 2013 HavannaV1.2.1 avril 2014 IcehouseV1.2.2 octobre 2014 JunoV1.2.3 avril 2015 KiloV1.3 octobre 2015 LibertyVx avril 2016 ? MitakaVx octobre 2016 ? NewtonVx avril 2017 ? Ocata

Aujourd'hui

Les noms des releases OpenStack sont choisis par la communauté :https://wiki.openstack.org/wiki/Release_Naming

Archéologie :-)

Page 38: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation38

● Dynamic Resource Optimizer (DRO)

● PowerVM NovaLink support

● Enhanced fabric management via storage connectivity groups

● Manage up to 26 fabrics

● IBM System Storage DS8000 support

● Manage up to 5000 VMs and 50 physical chassis

● New supported guest operating systems

PowerVC Standard Edition Version 1.3

OS supported

● AIX 6.1 or later

● AIX 7.1 or later

● AIX 7.2 or later

● IBM i 7.1 TR 8 or later

● IBM i 7.2 TR 1 or later

● RHEL 5.9 or later (BE)

● RHEL 6.4 or later (BE)

● RHEL 7.1 (BE and LE) or later

● SLES 11 SP 3 or later (BE)

● SLES 12 SP 0 or later (LE)

● Ubuntu 14.04.03

● Ubuntu 15.04 or later

● Ubuntu 15.10

Page 39: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation39

La puissance et la simplicité d’OpenStack

OpenStack est un projet Open Source animé par les acteurs majeurs de l’IT mondiale, au travers de la fondation OpenStack

OpenStack offre une solution hautement interopérable de service d’infrastructure (IaaS) : serveurs, stockage et réseau

Les principes d’OpenStack :

Simplicité

Interopérabilité par les API ouvertes

Scalabilité pour les plus grands clouds

Ouverture du framework par l’OpenSource

OpenStack est au cœur de la statégie Cloud d’IBM

Page 40: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation40

PowerVC v1.2.1

- Annoncé le 28 avril 2014- Disponible depuis le 10 juin 2014- Les nouveautés :

http://www.redbooks.ibm.com/Redbooks.nsf/RedbookAbstracts/sg248199.html?Open IBM PowerVC Version 1.2.1 Introduction and Configuration

New supportPOWER8™ Servers are supported.Shared storage pools are supported.Red Hat Enterprise Linux 6.5 is supported on the management host.AIX® 7.1 TL3 and Red Hat Enterprise Linux 5.10 and 6.5 operating systems are supported on the managed hosts.VIOS version 2.2.3.0 is supported for POWER6® andPOWER7® servers.VIOS version 2.2.3.3 or later is supported for POWER8 servers.Microsoft Active Directory 2003 or later is supported as an LDAP server.PowerVC can manage up to 1000 virtual machines.

Functional enhancementsAutomatically assign Fibre Channel ports to fabricsStorage connectivity groups support shared storage poolsStorage connectivity groups can provide connectivity to hosts with mixed configurations that contain shared storage pools and NPIV storage.Storage connectivity groups can provide connectivity to hosts with multiple shared storage pool clusters on one PowerVC instance. But each storage connectivity groups can provide connectivity to at most one shared storage pool cluster.

Enhancements to ensure network connectivityRestart a virtual machine from the PowerVC GUIAdd activation input at the time of deployAdd configuration data or upload configuration script at the time of deploying a virtual machine.Activate and initialize virtual machines with the cloud-init initialization packageREST API assistance with network placement decisionsAvoid LDAP user group conflictAdapt to a new IP address or host name

Page 41: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation41

PowerVC v1.2.2

- Annoncé le 6 octobre 2014- Disponible le 12 décembre 2014- Les nouveautés :

New support Cisco SAN fabric IBM XIV storage devices EMC VMAX storage devices EMC VNX storage devices EMC PowerPath client support Classic vSCSI (SAN volume backed only, no local disks) Export/Import virtual machine images between storage devices Multiple I/O Group support for SAN Volume Controller (SVC) PowerVM : IBM i (Requires IBM i 7.1 TR7 or 7.2) RHEL 7 (Included in PowerVC 1.2.1 Fixpack 2) PowerKVM : SLES 12 (little endian) Ubuntu V14 (little endian)

Functional enhancements One-Click System Evacuation (aka Maintenance Mode)Add/Remove Virtual network interface (VNIC) after the initial VM deploymentIP address poolsExpanded auditingThird party supported OpenStack Drivers (Included in PowerVC 1.2.1 Fixpack 2)

Page 42: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation42

PowerVC v1.2.3

- Annoncé le 6 avril 2015- Disponible le 10 juin 2015- Les nouveautés :

Enhanced storage support – Multiple disk capture/deploy– Resize data volumes– Shared storage devices for HA solutions– SVC Mirroring– IBM SDDPCM & EMC PowerPath in VIOS

New clients supported on PowerVM–RHEL 7.1 (LE)–SLES 12 (LE)–Ubuntu V15.04 (LE)

Management server RHEL 7.1 New management features

– Advanced placement capabilities •Virtual Machine Affinity and Anti-affinity •Host system CPU and memory free capacity•Host system CPU utilization

– Physical server Host Groups– Redundant HMC support– Manual Remote VM Restart (POWER8 only) – CloudInit support for AIX 6 and AIX 7 clients– Networking enhancements

Scaling to 30 servers and 3000 VMs PowerVC Express Edition withdrawn from marketing

http://www.redbooks.ibm.com/redbooks/pdfs/sg248199.pdf IBM PowerVC Version 1.2.3: Introduction and Configuration

Page 43: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation43

PowerVC v1.3

- Annoncé le 5 octobre 2015- Disponible le 10 décembre 2015- Les nouveautés :

New support Cisco SAN fabric IBM XIV storage devices EMC VMAX storage devices EMC VNX storage devices EMC PowerPath client support Classic vSCSI (SAN volume backed only, no local disks) Export/Import virtual machine images between storage devices Multiple I/O Group support for SAN Volume Controller (SVC) PowerVM : IBM i (Requires IBM i 7.1 TR7 or 7.2) RHEL 7 (Included in PowerVC 1.2.1 Fixpack 2) PowerKVM : SLES 12 (little endian) Ubuntu V14 (little endian)

Functional enhancements One-Click System Evacuation (aka Maintenance Mode)Add/Remove Virtual network interface (VNIC) after the initial VM deploymentIP address poolsExpanded auditingThird party supported OpenStack Drivers (Included in PowerVC 1.2.1 Fixpack 2)Scaling to 50 servers and 5000 VMs

Page 44: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation44

What Can PowerVC do for you?

“A simple tool to quickly roll out LPARs/Virtual Machines on Power Systems”

Easily clone, resize, and relocate Power Systems virtual machines– Increase agility and execution to quickly respond to changing business requirements – Complete virtual machine provisioning including Storage, Compute, and Network – Policy-based placement of new and relocated virtual machines– Remote restart of Virtual Machines from failed physical hosts (POWER8 only)

Quick and easy installation to get you up and running quickly– One button verification of stack integration and operational environment – Simplify operations by not having to logon to HMC, VIOS, or storage to provision virtual machines– Easy to use user interface and completely programmable API

Upward integration to cloud managers for private cloud management– Build on OpenStack APIs for automation and extensibility– Integration to Cloud Manager with OpenStack for POWER (formerly SmartCloud Entry)– Planned integration to IBM Cloud Orchestrator (formerly SmartCloud Orchestrator)

Page 45: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation45

PowerVC 1.3.0 Summary Available 04/12 2015

Enhanced storage support – Increase size of data volumes – Support for up to 26 SAN fabrics– DS8870 storage support (NPIV & vSCSI)

Exploitation of Novalink architecture management interface – Alternative to HMC for POWER8 servers– Provides increased management scalability

Support for PowerVC Multiple Shared Processor Pools –Improved control for applications that need to control processor capacity for software licensing

Dynamic Resource Optimizer automatic workload balancing– Relocate VM to less loaded servers– Move server capacity between servers using Enterprise Capacity on Demand

Based on the OpenStack “Liberty” release

Page 46: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation46

Host 2

PowerVC V1.3.0 Dynamic Resource Optimizer

Host 1 Host 3

PowerVC Dynamic Resource Optimizer allows for automated rebalancing of workloads between servers• Server workload can be automatically balanced two ways:

• Relocating Virtual Machines between servers• Moving processor capacity between servers using Power Enterprise Pool

Capacity on Demand • Works with AIX, IBM i or Linux VMs

PowerVC Dynamic Resource Optimizer allows for automated rebalancing of workloads between servers• Server workload can be automatically balanced two ways:

• Relocating Virtual Machines between servers• Moving processor capacity between servers using Power Enterprise Pool

Capacity on Demand • Works with AIX, IBM i or Linux VMs

Policy-based automation to balance workloads

Relocate VM

Relocate VM

Move server Capacity with COD

Page 47: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation47

PowerVC pré requis coeur & mémoire

http://ibm.biz/PowerVC13-requirements

Page 48: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation48

NovaLink architecture: POWER8 Platform Management

Goal: Simplify PowerVM virtualization, accelerate cloud enablement, and improve scale

PowerVM

PHYP

FSP

HMC

VIOSVIOSVIOS

Controller

OpenStack

NovaOpenStack

NovaOpenStack

Nova

PowerVM

PHYP

FSP

Novalink

VIOSVIOSVIOS

Controller

BecomesBecomes

Key Benefits Improved management scalability – support more virtual machines

Aligns PowerVM with the OpenStack community scale model – simplifying future OpenStack exploitation

Simplifies management configuration – HMC not needed for virtual machine deployment and configuration

Enables flexibility to use any OpenStack based manager to manage PowerVM

Uniform management for PowerVM and PowerKVM based systems

Key Benefits Improved management scalability – support more virtual machines

Aligns PowerVM with the OpenStack community scale model – simplifying future OpenStack exploitation

Simplifies management configuration – HMC not needed for virtual machine deployment and configuration

Enables flexibility to use any OpenStack based manager to manage PowerVM

Uniform management for PowerVM and PowerKVM based systems

OpenStack

Nova

Page 49: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation49

CloudInit for AIX image activation at deployment● PowerVC V1.2.3 will support CloudInit for image activation on AIX

– Image activation is the process that automatically runs when a new VM image is deployed to customize the VM instance

• For example, to set the hostname, networking configuration, and SSH keys– PowerVC formerly only supported the proprietary VSAE activation engine

● CloudInit has become the defacto standard for activation – Open source project used by OpenStack, AWS and other clouds– CloudInit supports a much richer activation technology

• Supports passing in customer activation scripts• Built in modules for Chef, Puppet, and user creation, etc.

– Upstream cloud managers are highly dependent on CloudInit

● More information can be found at: http://cloudinit.readthedocs.org/en/latest/

Page 50: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation50

CloudInit for AIX image activation at deployment

http://www.rootvg.net/content/view/758/114/

Tout en un !

Installation dans : /opt/lib/python2.7/site-packages/

Publicité !

Non packagé par IBM

Page 51: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation51

Dès la connexion une vue globale !

Page 52: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation52

Catalogue des images, prêtes à déployer

Page 53: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation53

Page 54: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation54

vHMC 5765-HMV Virtual Appliance v8.8.4

PowerHMC

V8.8.4

PowerHMC

V8.8.4

POWER6POWER6 POWER7POWER7 POWE8POWE8

VMware ESXi or Red Hat KVMVMware ESXi or Red Hat KVM

• Same functionality as traditional HMC

• x86 64-bit with Intel VT-x or AMD-V

• 4 CPU, 8 GB memory, 160 GB disk, 2 NIC

• Mix HW and virtual HMC

• License plus SWMA

Clients can use Power Systems HMCs in any of the following configurations:

● Only hardware appliance HMCs

● Only virtual appliance HMCs

● A combination of hardware appliance and virtual appliance HMCs

Page 55: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation55

vHMC 5765-HMV Virtual Appliance v8.8.4

Refreshed rack-mounted HMC– For POWER6 and later servers– 7042-CR9 --- follow-on to CR8

New HMC virtual appliance (vHMC)– For POWER6, POWER7, POWER8 servers– Same functionality as traditional HMC (version 8)– Runs as virtual machine on x86 server

One or two HMCsOne vHMC and

one HMCOne or two vHMCs

Options for attachment to a server

Page 56: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation56

HMC 7042-CR9

Support POWER6, POWER7 and POWER8

The new HMC has the following standard hardware attributes:

● 2.4 GHz Intel Xeon™ Processor E5-2620 v3

● 16 GB (1 x 16 GB) of 2.133 GHz DDR4 system memory

● 500 GB SATA SFF HDD

● SATA CD/RW - DVD-RAM

● Four Ethernet ports

● Six USB ports (two front, four rear)

● One PCIe slot

The new 7042-CR9, by default, includes two hard disk drives (HDD) with RAID 1 configured

The 7042-CR9 HMC requires a minimum HMC code level of 8.4.0.

Rest APIs supplied

Page 57: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation57

✗ Nouveautés AIX 7.2 dont LKU

✗ Automatisation via PowerVC et Novalink Nouvelle vHMC

✗ Quid de la disponibilité dans l'environnement AIX ?PowerHA – LPM - SSR

30 mn

60 mn

45 mn9:15 – 9:45

11:15 – 12:00

14:15 – 15:15

Agenda

SimplifiedRemote Restart

Page 58: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation58

PowerHA 7.2

● Saves you time and money by integrating IBM Power® Enterprise Pools and Elastic Capacity on Demand as part of a PowerHA failover operation.

● Enables automation that eliminates the need for an operator to conduct manual steps to perform a live partition mobility (LPM) move or AIX Live Update.

● Automatically replaces failed repository disk.

● Upgrade from PowerHA V7.1.3 and beyond without disruption

● Performs automatic verification checks for AIX and PowerHA across all the nodes in the cluster, thereby eliminating operator effort and error.

● Includes quarantine policies for handling cluster splits, eliminating the potential for data corruption. Disk fencing and HMC-based active node shoot-downs to isolate the sick node.

● Enables tie breaker to be set up using an NFS server.

● Includes a wizard to configure GLVM (low cost mirroring) in a PowerHA cluster.

● Enables manual control for mirror resync operations in EMC SRDF deployments.

AIX 6.1 technology level (TL) 09 and AIX 7.1 TL03 support PowerHA V7.2.

Some of the advanced features available in PowerHA V7.2 are available only with the 2015 AIX releases: AIX 7.1 TL04 and AIX 7.2.

5765-H39 V7.2.0 IBM PowerHA SystemMirror V7.2 Standard edition for AIX

5765-H37 V7.2.0 IBM PowerHA System Mirror V7.2 Enterprise edition for AIX

Page 59: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation59

PowerHA V7.2 CoD and Enterprise Pool Support Summary

CoD Offering Type PowerHA 7.1 PowerHA 7.2

Permanent CPU, Memory Yes

On/OffCPU Yes Yes

Memory No Yes

Utility CoD CPU, MemoryUtility CoD automatically is performed at

PHYP/System level. PowerHA can not play a role in the same

Trial CoD CPU, Memory Yes

Enterprise Pools

CPU, Memory No Yes

Page 60: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation60

PowerHA for AIX: Resource Optimized High Availability (ROHA)

Active LPAR

Hypervisor

HMC

POWER Enterprise PoolCoD

Application

Hypervisor

Standby LPAR

● PowerHA Enterprise Pool and CoD integrated management

● Significant cost savings in both hardware and software

● Shared HMC required (1H 2016 independent HMCs should communicate between remote sites for disaster recovery implementations)

Customer Benefits

PowerHA Cluster

failover

Application

Page 61: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation61

Offering for – AIX and IBM i Power E880 customers – HA/DR deployments requiring fast failover via active

standby memory and processors

Offering Entitlements– One or two no charge processor nodes depending on

the primary server configuration – No charge active standby memory and processor cores

via Elastic Capacity on Demand (ECOD) = PowerHA licensed cores on the primary system (minus 8 for required the activations on the CBU)

Offering requirements overview– Primary and CBU must be same GHz of Power E880– Primary can be new or installed box, CBU must be a new

box– Primary system must have a minimum of 75% of the

processors activated and 50% of installed DIMM memory active

– One entitlement of AIX or IBM i & PowerHA non transferable

– Maximum of 8 processor activations on the CBU and minimum of 25% of DIMM memory active

– Minimum of 8 PowerHA entitlements on the primary system– No charge ECOD days must be activated upon install of

CBU system and remain active for 365 days – The ECOD processor days can only be used on the Power

E880 CBU system and must be renewed annually and customer is required to maintain minimum requirements

– Registration of primary system and CBU prior to CBU order fulfillment (registration validates minimum requirements)

– Primary and CBU must be within the same enterprise

Primary CBU

entitlement transferentitlement transfer

• All transferable entitlements must originate on the primary system and may not run concurrently on the primary system and the CBU system

• Subsequent to the initial workload deployment, production partitions may be moved to the CBU system for workload balancing etc

• The total number of processor entitlements running production across both servers can not exceed the original total licensed entitlements.

Power Systems CBU for PowerHA

Page 62: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation62

Power E880 Servers in a CBU for PowerHA configuration

Power E880 CBU System: • 4.35 Ghz or 4.0 Ghz system (must match primary)• 1 to 4 nodes per CBU system*• Node feature codes:EPBG,EPBH,EPBB,EPBD• Maximum of 8 active cores • 365 x N-8 = # of no charge ECOD processor days• 365 x N-8 x 32 GB no charge ECOD memory days• 25% of DIMM memory active

Power E880 Primay System:• 4.35 GHz or 4.0 GHz system• 1 to 4 nodes per system • Node feature codes: EPBB, EPBD• N cores of PowerHA entitlements• 75% of installed processors must be

active• 50% DIMM memory active

CBU system specify feature code: EB3J

*Select processor nodes from:• No charge processor nodes: EPBG, EPBH

• One or two nodes on the primary = 1 no-charge node on the CBU• Three or four nodes on the primary = 2 no-charge nodes on the CBU

• For charge processor nodes: EPBB, EPBD

PowerHA cluster

Page 63: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation63

SPP size can be dynamically increased.User agrees on this change through a tunable

Customer pays for a 7 CPUs application license, as he has 6 CPUs on active frame, and 1 CPU on backup frame. Customer expects the SPP size to be adjusted on both nodes, active node and backup node, at takeover time (and then that the CoD CPUs are assigned to this LPAR)

PowerHA managed Shared Processor Pool resizing

Page 64: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation64

PowerHA V7.2 AIX Live Update Support

Automated handling of AIX Live Update PowerHA is switched to Unmanage node

mode during the operation– Workload continues to run – All the storage (vg, disk support etc)

activities continue without interruption Live Update can be performed on one node

in the Cluster at a time Coverage for all key features: HyperSwap,

Sync GLVM Asynchronous GLVM needs to be switched

to sync GLVM mode during the LKU process.

Node A Node B

System 1

LiveUpdate

PowerHA Cluster

Node A

System 2

Page 65: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation65

http://ibm.biz/POWERHA72-limits

PowerHA SystemMirror maximum limits

PowerHA SystemMirror adapter sup.

http://ibm.biz/POWERHA72-adapters

FLASH10825

Page 66: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation66

PowerHA SystemMirror Editions

Page 67: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation67

Unicast ou multicast

Ne pas oublierdepuis la version 7.1.3

choix possible

Page 68: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation68

Simplified Remote Restart or SRR

Modification :- La partition doit être redémarrée si la modification est faite par le gui- ok par ligne de commande- RestAPI “SimplifiedRemoteRestartCapable=true”

reserved device storage

Page 69: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation69

Simplified Remote Restart or SRR

!

- Même prérequis que pour le LPM concernant les entrées/sorties (virtualisés et visibles de deux chassis)

- POWER8 Firmware SC820 ou SV830 minimum POWER8 HMC V8R8.2.0 VIOS 2.2.3.4 ou plus récent

- Avec SSP : FW820, HMC V8R8.4.0, VIOS 2.2.4.0, ou plus récent

Jusqu'à quatre opérations SSR simultanées supportées par chassis cible

Les informations nécessaires pour le SRR sont stockés sur la HMC

HMC1HMC2

Server1 Server2

VM VM

HMC1 HMC1 HMC2HMC2

OK !

*** La HMC initiatrice de la commande rrstartlpar doit être connecté aux deux serveurs ***

Page 70: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation70

Simplified Remote Restart or SRR

rrstartlpar -o start

validate

-- force -- usesurrdata

cancel

restart-m <source server> -t <destination server> -p <lpar name> | id <lpar id>

Pour qu'une opération SSR soit possible, le serveur source doit être dans un des états suivants :- Error- Dump in Progress- PowerOff

cleanup

Page 71: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation71

https://www.ibm.com/developerworks/community/forums/html/topic?id=536157a9-9f39-4a29-b362-d461ee62f03a&ps=25

ou http://ibm.biz/POWER-SSR

Simplified Remote Restart or SRR

Page 72: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation72

Live Partition Mobility

Disponible depuis 2007 et le POWER6

Depuis, LPM a été amélioré, disponible sur POWER7 et POWER8

Original LPM Support (pre-VIOS 2.2.2.0) 4 concurrent LPM operations per MSP

VIOS 2.2.2.0: adds support for 8/16 Concurrent LPM Operations (Support for 8 concurrent LPM operations per MSP (16 on a system) added)

VIOS 2.2.3.0 - adds support for 16/32 Concurrent LPM Operations.

VIOS 2.2.4.0 : Validation for NPIV attached storage at the port and disk level

The concurrency level attribute http://ibm.biz/LPM-Concurrent-level

→ Cas d'usage intensif chez nos clients

Page 73: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation73

Différences

Live OS/App move between physical frames*

X

Server Workload Management ** X

Energy Management ** X

Hardware Maintenance X X

Software Maintenance X

Automated failover upon System Failure (OS or HW)

X

Automated failover upon HW failure X X ***

Automated failover upon App failure X

Automated failover upon vg access loss X

Automated failover upon any specified AIX error (via customized error notification of error report entry)

X

* ~ 2 seconds of total interruption time *** physical chassis** Require free system resources on target system

SimplifiedRemote Restart

Page 74: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation74

A partir de PowerVC v1.2.3

https://www.ibm.com/developerworks/community/wikis/home?lang=en#!/wiki/Wc1c29d23e0fd_4346_b509_f1c00a2099f0/page/Remote%20Restart%20Overview

http://ibm.biz/PowerVC-RR

ou

Page 75: IBM Power systems - common- · PDF fileAny Power System running AIX 7.2 Power System running AIX 7.2 SAN IBM, non-IBM Flash memory Read Cache Supported Flash memory technology •

© 2016 IBM Corporation75

Philippe Hermès

Client Technical SpecialistIBM Systems HW [email protected]

IBM France17 Avenue de l'Europe92275 Bois Colombes +33 1 5875 2368

M E R C I !

https://twitter.com/phhermes/

https://fr.linkedin.com/in/philippehermes