    i-ALERT2 Application Guide 25 of 54

    MOUNTING METHODS

    There are three methods that can be used to mount the i-ALERT2 deviceto a machine. They are shown in the figure below.

    On new pumps and pumps repaired through ITT PRO Services, a slot will be milled into an appropriate location on the

    bearing housing and the device will be secured with a screw. Alternatively, a hole can be drilled and tapped and a small

    adapter plate can then be used to secure the device. Lastly, the device can be epoxied directly the machine via the

    mounting plate. Make sure to use a good quality, rigid epoxy. Do not use RTV or Silicon to mount the device.

    CAUTION:

    Always wear protective gloves. The equipment and the i-ALERT2device can be hot.

    Mill a Slot Drill and Tap Epoxy

    Screw: -28 x 1.125in Screw: -28 x 1.5in Screw: -28 x 1.125in

    Slot: 2.25in L x 1.6in W Tap: -28 UNF x in deep Epoxy: application specific

    COMMISSIONING

    STEPS TO ACTIVATE THE I-ALERT2 EQUIPMENT HEALTH MONITOR:

    1. Remove the sticker.

    2. The i-ALERT2 devicewill look for light. Note: If in a dark environment use light source to activate.

    3. When activated a sequence of flashing LEDs will start to indicate that the unit is powered on.

    4. When sequence is completed the green LED will flash every 5 sec under normal operating conditions

    Figure 23: Mounting Methods