HYPERTEC UNINTERRUPTIBLE POWER SUPPLY USER’S MANUAL SBUPS600VA SBUPS1000VA SBUPS1500VA

HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

HYPERTEC UNINTERRUPTIBLE

POWER SUPPLY

USER’S MANUAL SBUPS600VA

SBUPS1000VA SBUPS1500VA

Page 2: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

Contents General Safety Instructions 2 Conditions of Use 2 Electrical Safety 3Safe Operating Practices 4Battery Information 6 Introduction 7

Performance 7 Installation Instructions 9 Physical Appearance 10 Front Panel Operational Indicators 11Operation 12 Specification 13 Maintenance 14 Software Installation 15 Load configure reference 19Troubleshooting 20

1

Page 3: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

General safety instructions This manual contains important safety instructions that should be followed

during the installation and maintenance of the UPS.

Please read this manual thoroughly before attempting to install or operate

this UPS.

DO NOT under any circumstances attempt to remove the UPS cover.

It may contain hazardous voltages internally that may cause electric

shock. There are no user-serviceable parts inside. For service,

please contact your nominated service agent.

Conditions of Use This equipment is designed for domestic use only. The manufacturer

neither recommends nor knowingly sells this product for use in critical life

support applications.

1. Intended for installation in a controlled environment.

a. The controlled environment should be in accordance

with the requirement of the specification

b. Do not install or operate your UPS in or near water.

c. Do not place UPS on an unstable cart, stand or table.

d. Do not place UPS under direct sunlight or close to

heat emitting sources.

e. Do not place UPS power cord in any area where it may

2

Page 4: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

get damaged by heavy objects.

2. Placing magnetic storage media on top of the UPS may result in data

corruption.

3. Your UPS provides conditioned power to connected equipment.

Maximum load must not exceed that shown on the UPS rating label.

If uncertain, contact Legend

Electrical Safety DO NOT under any circumstances attempt to remove the UPS cover.

It may contain hazardous voltages internally that may cause electric

shock. There are no user-serviceable parts inside. For service,

please contact your nominated service agent.

1. The Hypertec UPS will provide a 220~240VAC 1φ(single-phase)rate

power source. Please verify that this model matches your AC mains /

load voltage requirements.

2. The Hypertec UPS must be earthed at all times during operation.

This can be achieved by only connecting the input power chord to a

mains supply socket outlet with an integral earth terminal. A means of

disconnecting the mains supply should be within 2 meters of the

UPS.

3. Output sockets on the UPS are electrically live if the UPS is switched

3

Page 5: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

ON, even if the UPS is not plugged in to mains supply. The On/Off

button on the UPS does not electrically isolate the internal parts. To

isolate the UPS, switch the UPS OFF first, then unplug it from the

mains.

4. To reduce the risk of fire, use fuses with the correct rating when

replacing fuses.

5. The UPS relies on your building wiring over-current protection, which

must be rated between 10-16 amperes.

6. When using the communication features on the UPS, ensure the

cabling connected to the USB communication port are kept

separated by at least 25 mm from the power cords to and from the

UPS input and output.

Safe Operating Practices This pluggable type A equipment has factory installed batteries, and hence

may be operated by anyone that has read and understood this manual.

During the installation of this equipment, it should be assured that the sum

of the leakage currents of the UPS and the connected loads does not

exceed 3.5mA.

1. The mains socket outlet that supplies the UPS shall be installed near

the UPS and shall be easily accessible.

2. When replacing batteries, replace with the same type and number of

batteries.

3. Turn off and unplug your UPS before cleaning. Do not use liquid or

4

Page 6: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

aerosol cleaners. A dry cloth is recommended to remove dust from

the surface of your UPS.

4. Do not handle any metallic connector before the power has been

disconnected.

5. Turn off and unplug your UPS from the outlet and contact your

nominated service agent if:

o The power cord or plug damaged.

o Liquid has been spilled on the UPS.

o The fuse blows frequently.

o The UPS does not operate even when user follows

the operating instructions.

5

Page 7: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

Battery Information 1. CAUTION: Do not dispose of batteries in a fire, the battery may

explode.

2. CAUTION: Do not open or damage the battery or batteries, as

released electrolyte is harmful to the skin and eyes.

3. A battery can present a risk of electric shock and high short circuit

current. The following precaution should be observed when working

on batteries: Remove watches, rings or other metal objects. Use

tools with insulated handles.

4. NOTE. The batteries used in your Hypertec UPS are maintenance

free. This means that you DO NOT need to check the battery fluid

levels. Trying to do so may cause injury to yourself, or may cause a

fault with the battery / UPS.

5. The battery backup runtime is affected by the state of charge of the

batteries, the age of the batteries and general condition of the

batteries.

6

Page 8: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

Introduction The Hypertec UPS can instantly switch your computer to emergency

battery backup power and allows you to work through mains power

outages without data loss or downtime. It continuously conditions the

power coming into your computer and provides a power source with

virtually zero interruption.

This UPS is specially designed for PC users and also suitable for

computer peripherals or POS. A microcontroller is used as the main

controller that renders the product an intelligent UPS, capable of

self-protection and fault diagnosis. A built-in AVR function automatically

adjusts itself to maintain a power supply of stable voltage when the utility

power is of high or low voltage. High-performance surge suppression

protects your computer from electrical noise and damaging power surges.

Performance Your Hypertec UPS provides the following high performance features:

• Uninterruptible Power

Protects your data by supplying battery backup when power fails.

• Microcontroller Control

By means of innovative software control programs, the complicated

hardware circuitry is inlaid in the powerful microcontroller. Apart from

reduced size, it also lowers the rate of UPS failure.

• LED Indicators

7

Page 9: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

Operational status is indicated by a series of 3 easy to read LED’s.

• Audible Alarms

Actively lets you know if the unit is in battery mode, if the battery is low, or

if there is an over load condition.

• High quality battery

The selection of high quality sealed lead-acid maintenance free batteries

maximises the life span of the battery for prolonged performance and

enhanced economic benefits.

• Automatic Detection

When the UPS is turned ON, it immediately performs an inspection of the

battery capacity.

• Automatic Voltage Regulation

Corrects over and under-voltages, without draining the battery. This

preserves battery resources and ensures your UPS will provide the

optimum runtime and optimum voltage source during a power blackout.

• Surge Protection

Protects hardware from damage due to unexpected power surges.

• Automatic Charge

The UPS charges its battery whenever it is connected to utility power. The

UPS can be in either the ON or OFF mode.

• Auto Restart (Cold Start)

If the UPS has shutdown during a battery backup session due to

discharged batteries, the UPS will automatically restart once mains power

has been restored to supply mains power and recharge the batteries.

8

Page 10: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

Installation Instructions 1. Inspection

Inspect the UPS upon receipt. The packaging is recyclable. Save it for

reuse or dispose of it properly. Ensure the UPS is physically undamaged

due to transit.

2. Placement

Install the UPS in a protected area with adequate airflow, and away from

direct sunlight and excessive dust. Do not operate the UPS where the

temperature and humidity is outside the specified limits in the

Specifications Table.

3. Connect to Mains Power

Connect the AC input power cord to a socket outlet to power up the UPS.

The battery in the UPS will lose some charge during shipping and storage.

It will recharge completely after approximately 8 hours of normal operation.

Do not expect full battery run time during this initial recharge period.

4. Connect the loads

Plug the loads into the output sockets on the rear of the UPS. Ensure the

UPS is sized correctly so that the UPS is not run at full load constantly.

Caution: NDO NOT connect a laser printer or plotter to the UPS with other

computer equipment. A laser printer or plotter periodically draws

significantly more power than when idle, and may overload the UPS.

9

Page 11: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

Physical Appearance Front Panel

Rear Panel

Item Description

1 On/Off Power Switch

2 LED 1 - GREEN - AC Normal Status LED

3 LED 2 - YELLOW - Battery Charging LED

4 LED 3 - RED – Battery State of charge LED

5 AC Power socket outlets

6 Phone/Fax line Surge Suppressor

7 USB Communications Port

8 Input AC Fuse

9 Input Power Socket with Spare Fuse

1

2

3

4

5

6

7

8

9

10

Page 12: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

Front Panel Operational Indicators Front Panel Indicator

LED 1

Green

LED2

Yellow

LED 3

Red

Buzzer Status Operational

Description

OFF ON OFF OFF

UPS OFF.

Mains Normal.

Batteries Charging.

ON ON OFF 2 second Interval

Beeping

UPS ON.

Mains Mode

OFF OFF BLINK Beeping every 5

seconds

Mains not present.

Battery Backup mode

2 beeps per

second i. Low battery Voltage

4 beeps every 2

seconds ii. Overload

OFF OFF ON

Continuous iii. Short-circuit

OFF OFF OFF OFF Batteries Discharged.

Sleep Mode.

11

Page 13: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

Operation • Switch On - With the UPS plugged in, press the power switch in to

switch the UPS on. The UPS will perform a self-test each time it

is switched on and the buzzer will beep 2 times.

• Switch Off - By depressing the power switch. UPS will keep charging

batteries.

• Backup (Beeping 1 time every 5 seconds) - When in Backup mode,

the battery illuminates and the UPS emits a beeping sound

every four seconds. Press the power switch to stop the beeping.

The alarm stops when the UPS returns to normal utility mode of

operation

• Low Battery (Beeping 2 times every 1 second) - In Backup mode,

when the battery energy runs low, the UPS beeps rapidly until

the UPS shuts down due to complete battery discharge.

• Overload (Beeping 4 times every 2 seconds) - When the UPS is

overloaded all three LED’s turn on and the buzzer beeps every

1 second. Promptly disconnect non-essential load equipment

from the UPS to eliminate the overload, otherwise, the UPS will

shut off output power. The time for shut-down is determined by

the size of the overload

• NOTE: If the UPS is working in battery mode, DO NOT turn on

any additional loads such as a computer or monitor or

return any loads from sleep mode, otherwise, the UPS may

operate its overload or short circuit protection.

12

Page 14: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

Specification Model SBUPS600VA SBUPS1000VA SBUPS1500VA

Rated Output

power 600VA / 360W 1000VA / 600W 1500VA / 750W

Input Characteristics

Rated Input Voltage 230/240V

Input Voltage Range 175 – 285 V

Rated Input Frequency 50 Hz ± 10%

Output Characteristics

Rated Output Voltage 230V ± 10%

Output Frequency 50 Hz ± 10%

Output Waveform Modified Square Wave

Power Factor 0.6

Change Over Time Typ. 0.4ms

Max. 10ms

Battery Information (at 25°C)

Rating 1 x 12Vdc, 7Ah 2 x 12Vdc, 7Ah 2 x 12Vdc, 9Ah

Type Sealed Lead Acid, Maintenance Free

Service Life 2-3 years depending upon use

Battery Recharge time

for 90% capacity 8 hours

Runtime in minutes at

full load ≥ 3 mins

13

Page 15: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

General

Audible Noise < 45dBA

Net Mass 6 kg 10.9 kg 12.5 kg

Dimensions(mm) 162×94×320 124×382×225

Operating Temperature -10°C to +40°C

Maximum Operating

Relative Humidity 95% Relative

Maintenance 1. With normal use, a UPS battery will last 2 to 3 years depending on the

number of discharges and operating/ambient temperatures.

2. Charge the UPS's battery every 3 months during extended storage.

3. Disconnect the power during extended storage to avoid overcharge of

the battery.

4. Avoid overload or short circuit even though the UPS has build-in

overload and short circuit protect function.

14

Page 16: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

Software Installation In order to utilise the UPS to its full potential, the monitoring software must

first be installed. Please install the software according to the following

steps. For information on how to operate the software, refer to the On-CD

manual

When the software

CD is inserted, The

Autorun screen will

come up.

Click Install.

Click NEXT

15

Page 17: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

3. Enter details as

requested on this

screen. Your

product serial

number will be on

the CD envelope.

Click NEXT

4. Choose the

installation

directory.

Click Next.

16

Page 18: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

5. Select language.

English is Default.

Click NEXT.

6. Software will

Now Install.

17

Page 19: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

7. Installation is

now complete.

Click FINISH

8. The program is

now running.

For information on

how to operate the

software, refer to

the On-CD manual.

18

Page 20: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

Load configuration reference

UPS (VA) = PC power ATX (Watt) /0.6 + Monitor (VA)

Monitor power ( reference )

15”CRT 15”LCD 17”CRT 17”LCD 19”CRT 19”LCD

80VA 40VA 130VA 60VA 180VA 80VA

19

Page 21: HYPERTEC UNINTERRUPTIBLE POWER SUPPLY€¦ · protects your computer from electrical noise and damaging power surges. Performance Your Hypertec UPS provides the following high performance

Troubleshooting Problem Possible Cause Action To Take

i. Battery Discharged.

Sleep Mode. Press the POWER button ONUPS not on &

No LED’s on ii. PCB failure Contact Service Agent

Power cord lose Re-plug the power cord

Line voltage too high, too

low or black out Normal condition

UPS always at battery

mode

PCB failure Contact Service Agent

i. Short Circuit. Remove the non-critical loadsBuzzer continuously

sounding ii. UPS Faulty Contact Service Agent

UPS does not provide

expected run time. Low

battery warning is

sounded prematurely.

Battery is weak due to

wear or successive mains

outages.

Allow UPS to recharge battery

for a minimum of 8 hours. If

UPS sounds low battery

warning prematurely, when

retested, battery should be

replaced.

20