Hydrotherm’s NEWKN Series
Condensing BoilersCondensing Boilers
When They Make CENTS!Beware Of’sDisadvantagesAdvantages
Why Hydrotherm is the Condensing Boiler of Choice!
When They Make “Cents”
When They Make “Cents”
Low Temperature Application180F – 200F Cannot Afford the Average Condensing Boiler.Savings = Efficiency – First Cost!Carefully Consider All the Additional Installation Cost!
RE
TU
RN
TE
MP
6060FF
18180F0F
EF
FIC
IEN
CY
9898%%
8383%%
BUDGET 2000 MBH BOILER:BUDGET 2000 MBH BOILER:
COPPER FIN 85% - $14,000.00
CAST IRON FD - $ 9,500.00
STEEL FD - $14,500.00
COPPER FIN 82% - $ 9,000.00
ATMOSPHERIC - $ 7,500.00
CONDENSING CONDENSING BOILERS:BOILERS:
$18,000.00 - $18,000.00 -
$ 25,000.00$ 25,000.00
DON’T FORGET HIGH DON’T FORGET HIGH EFFICIENCY MAY MEAN:EFFICIENCY MAY MEAN:
SPECIAL VENT MATERIAL
CONDENSATION HANDLING
CONTROL CONSIDERATIONS
ADDITIONAL RADIATION
INCREASED MAINTENANCE
TECHNICALLY DEMANDING SERVICE
PROPRIETARY COMPONENTS
SPECIAL PUMPING OR PRIMARY/SECONDARY PIPING
( NOT ALL CONDENSING BOILER REQUIRE ALL OF THESE
CONSIDERATIONS )
Condensing “Beware Of’s”Condensing
“Beware Of’s”
VentingTemperature RiseGas PressuresCombustion Air RequirementExisting Conditions
Be sure to watch your EQUALS! Use disclaimers in Spec!
MASONRY CHIMNEYS CANNOT HANDLE CONDENSATION
AL29 ABOUT $90 PER FOOT
WATCH HORIZONTAL EQUIV.
MULTIPLE BOILERS AND HOW THEY ARE BREECHED.
CAN BE VERY NOISY.. WHERE IS MECH ROOM LOCATED
VARIES BY MANUFACTURER WATCH YOUR SPECS AND EQUALS!
THROUGH A BRICK WALL IS RISKY BUSINESS!
( NOT ALL CONDENSING BOILER REQUIRE ALL OF THESE
CONSIDERATIONS )
LOOK FOR PD AND GPM REQUIREMENTS.
LOW FLOW MEANS HIGH DELTA T. WATCH RISE AT HIGHER TEMPERATURES.
PRIMARY SECONDARY MAY BE NEEDED.
( NOT ALL CONDENSING BOILER REQUIRE ALL OF THESE
CONSIDERATIONS )
GAS REQUIREMENTS CAN BE AS HIGH AS 8” WC. TOUGH IN MANY AREAS OF CLEVELAND AND AKRON.
USE SPECIAL CARE WHEN USING MULTIPLE BOILERS.
ABILITY TO FIRE ALL BOILERS AT VARIOUS CAPABLE FIRING RATES MEANS ‘CAREFUL’ SIZING OF MAIN GAS BRANCH AND GAS DROPS TO BOILER.
( NOT ALL CONDENSING BOILER REQUIRE ALL OF THESE
CONSIDERATIONS )
NEGATIVE CONDITIONS CAUSE RANDOM HARD TO DETECT LOCKOUTS.
DIRECT CONNECT – BE SURE TO SPEC FACTORY FREEZE PROTECTION.
SIDEWALL – BE SURE TO USE SAME SIDEWALL AS VENT.
INLET AIR PIPE CAN CONDENSE AND DRIP IF NOT INSULATED OR DOUBLE WALL
DON’T COMBINE AIR INLETS
( NOT ALL CONDENSING BOILER REQUIRE ALL OF THESE
CONSIDERATIONS )
KNOW THE SYSTEM TEMPERATURE LIMITATIONS
CONDITION OF THE SYSTEM AND WATER (SMALL PASSAGES)
CONVERTING VENT? LINING CHIMNEY? SIDE WALL PLUME AND BRICK DAMAGE?
MULTIPLE BOILERS DON’T ALWAYS NEED HIGH TURNDOWNS.
WILL BACK LOADING MAKE SENSE?
DON’T LOOK AT LITERATURE FOR OUTPUT – CHECK CHART
( NOT ALL CONDENSING BOILER REQUIRE ALL OF THESE
CONSIDERATIONS )
Condensing ADVANTAGESCondensing
ADVANTAGES
EFFICIENT
TYPICAL SMALL FOOTPRINT
EASY RIG
SMALL VENTING
LOW VOLUME
FLEXIBLE INSTALLATION OPTIONS
Condensing DISADVANTAGES
Condensing DISADVANTAGES
EXPENSIVE
TECHNICALLY DEMANDING
HIGHLY PROPRIETARY
LESS FORGIVING
BURNER PULL
OFTEN REPS ONLY OPTION
VERY NON-STANDARD
Decide to Choose Condensing / Decide to Use The KN Series
Decide to Choose Condensing / Decide to Use The KN Series
SIMPLE AND EFFECTIVE
VERY NON-PROPRIETARY
CAST IRON DURABILITY
DESIGNED PASSIONATELY BY DEDICATED AND EXPERIENCED ENGINEER
NOT FLOW SENSITIVE
MANUFACTURER WITH A BACKBONE AND HISTORY OF SUPERIOR SUPPORT
COMPARATIVELY SUPERIOR
The CompetitionThe Competition
• AERCO KC-1000
• Fulton Pulse
• Lochinvar Intelli-Fin
• GasMaster 1M
• Buderus SB Series
• Viessmann Vertomat
• Ajax - Atlas Series
• Patterson Kelley MACH
• A.O. Smith Legend 2000
Similarities to Aerco KC1000Similarities to Aerco KC1000
BTU Outputs @ High and Low Inputs
Footprint
Vent Size and Category
Control Capability: 4-20ma Linear Signal Response
Flow Rates
Variable Flow
Piping Configurations:
Reverse Return OK.
No need for Primary/Secondary
Advantages Over Aerco KC1000
Advantages Over Aerco KC1000
KN-10 Fuel-Air Coupling -
Aerco high turndown comes at a cost Sooting and Poor Combustion
Aerco low pressure drop
Limits multiple boilers
Working Gas Pressures
2” w.c. vs 8.5” w.c.
Cast Iron 1/5 Energy Density of Copper
No Altitude De-Rate Necessary
Similarities to Fulton Pulse
Similarities to Fulton Pulse
Variable Flow Rates OK
Piping Configurations
Combustion Turndown
Efficiencies
Advantages Over Fulton Pulse
Advantages Over Fulton PulseNoise Level
No Accessories Required to Minimize Noise and
Vibration
Warranty
Operating Weight
Fuel-Air Coupling
Vent Distance (80’ vs 35’)
Footprint