Hydraulic MotorsM5AS/M5ASFDenison Vane Technology, fixed displacement
aerospaceclimate controlelectromechanicalfiltrationfluid & gas handlinghydraulicspneumaticsprocess controlsealing & shielding
Hydraulic MotorsM5AS/M5ASFDenison Vane Technology, Fixed Displacement
2
Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA
Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane Motors
3
ContentsCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
2 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
Warning .............................................................................. 2
General characteristics ....................................................... 3
Description ......................................................................... 4
Ports and hydraulic fluids..................................................... 5
Motor selection ................................................................... 6
Fluid power formulas .......................................................... 6
Performance data ............................................................... 7
Max. ratings ........................................................................ 8
Technical data .............................................................. 9 - 10
Ordering code ................................................................... 11
Motor with side ports - Dimensions .................................. 12
Motor with opposite ports - Dimensions ........................... 13
Ordering code ................................................................... 11
Motor with side ports - Dimensions .................................. 14
Motor with opposite ports - Dimensions ........................... 15
general
M5a - M5aS
M5aSF
Content
!FaIlUre Or IMPrOPer SeleCTIOn Or IMPrOPer USe OF THe PrODUCTS DeSCrIBeD HereIn Or relaTeD ITeMS Can CaUSe DeaTH, PerSOnal InJUrY anD PrOPerTY DaMage.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.
Offer of SalePlease contact your Parker representation for a detailed ”Offer of Sale”.
WARNING – USER RESPONSIBILITY
Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
2 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
Warning .............................................................................. 2
General characteristics ....................................................... 3
Description ......................................................................... 4
Ports and hydraulic fluids..................................................... 5
Motor selection ................................................................... 6
Fluid power formulas .......................................................... 6
Performance data ............................................................... 7
Max. ratings ........................................................................ 8
Technical data .............................................................. 9 - 10
Ordering code ................................................................... 11
Motor with side ports - Dimensions .................................. 12
Motor with opposite ports - Dimensions ........................... 13
Ordering code ................................................................... 11
Motor with side ports - Dimensions .................................. 14
Motor with opposite ports - Dimensions ........................... 15
general
M5a - M5aS
M5aSF
Content
!FaIlUre Or IMPrOPer SeleCTIOn Or IMPrOPer USe OF THe PrODUCTS DeSCrIBeD HereIn Or relaTeD ITeMS Can CaUSe DeaTH, PerSOnal InJUrY anD PrOPerTY DaMage.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.
Offer of SalePlease contact your Parker representation for a detailed ”Offer of Sale”.
WARNING – USER RESPONSIBILITY
2 3
Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA
Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane MotorsGeneral Characteristics
Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
2 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
Warning .............................................................................. 2
General characteristics ....................................................... 3
Description ......................................................................... 4
Ports and hydraulic fluids..................................................... 5
Motor selection ................................................................... 6
Fluid power formulas .......................................................... 6
Performance data ............................................................... 7
Max. ratings ........................................................................ 8
Technical data .............................................................. 9 - 10
Ordering code ................................................................... 11
Motor with side ports - Dimensions .................................. 12
Motor with opposite ports - Dimensions ........................... 13
Ordering code ................................................................... 11
Motor with side ports - Dimensions .................................. 14
Motor with opposite ports - Dimensions ........................... 15
general
M5a - M5aS
M5aSF
Content
!FaIlUre Or IMPrOPer SeleCTIOn Or IMPrOPer USe OF THe PrODUCTS DeSCrIBeD HereIn Or relaTeD ITeMS Can CaUSe DeaTH, PerSOnal InJUrY anD PrOPerTY DaMage.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.
Offer of SalePlease contact your Parker representation for a detailed ”Offer of Sale”.
WARNING – USER RESPONSIBILITY
Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
2 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
Warning .............................................................................. 2
General characteristics ....................................................... 3
Description ......................................................................... 4
Ports and hydraulic fluids..................................................... 5
Motor selection ................................................................... 6
Fluid power formulas .......................................................... 6
Performance data ............................................................... 7
Max. ratings ........................................................................ 8
Technical data .............................................................. 9 - 10
Ordering code ................................................................... 11
Motor with side ports - Dimensions .................................. 12
Motor with opposite ports - Dimensions ........................... 13
Ordering code ................................................................... 11
Motor with side ports - Dimensions .................................. 14
Motor with opposite ports - Dimensions ........................... 15
general
M5a - M5aS
M5aSF
Content
!FaIlUre Or IMPrOPer SeleCTIOn Or IMPrOPer USe OF THe PrODUCTS DeSCrIBeD HereIn Or relaTeD ITeMS Can CaUSe DeaTH, PerSOnal InJUrY anD PrOPerTY DaMage.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.
Offer of SalePlease contact your Parker representation for a detailed ”Offer of Sale”.
WARNING – USER RESPONSIBILITY
Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
3 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
12 vanes and a patented cartridge design allows a very low noise level, whatever the speed.
The M5 series have been designed especially for severe duty applications wich require high pressure , high speed and low fluid lubricity.
Max. pressure (continuous) : 280 barMax. speed (continuous)M5AS* 006 and 010 ................................................... : 5000 rpmM5AS* 012 and 016 ................................................... : 3800 rpmM5AS* 018 ................................................................. : 3300 rpmM5AS* 023 and 025 ................................................... : 2800 rpm
The high starting torque efficiency of the vane type motors allows them to start under high load without pressure overshoots, jerks and high instantaneous horsepower loads.
This 12 vane type motor exhibits a very low torque ripple (typical ± 1,5%), even at low speeds.
The vane, rotor and cam ring are pressure balanced to increase life over the full speed range. Double lip vanes reduce the sensitivity to fluid pollution.
Our precise manufacturing allows any component to be interchan-geable. Rotating groups may be easily replaced to renew the motor or change the displacement to suit altered requirements for speed or torque.
The M5AS and M5ASF externally drained, are available in three types of rotation : bi-directional, clockwise, counter-clockwise.
The uni-directional M5AS, M5ASF are designed with an internal valve that allows smooth dynamic braking, with a very simple hydraulic circuit and without risk of motor cavitation.
The M5AS, M5ASF motors have a stiff tapered or cylindrical keyed shaft and a high load capacity double ball bearing allow the direct mounting on shaft (like a fan for example).
For applications with motors in series or with high back pressure, please contact Parker.
lOW nOISe MOTOr
HIgH PerFOrManCe MOTOr
HIgH STarTIng TOrQUe
lOW TOrQUe rIPPle
lOng lIFeTIMe
InTerCHangeaBle rOTaTIng grOUPS
rOTaTIOn anD DraIn
CrOSS POrT CHeCK ValVe
MOUnTIng
general characteristicsCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
3 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
12 vanes and a patented cartridge design allows a very low noise level, whatever the speed.
The M5 series have been designed especially for severe duty applications wich require high pressure , high speed and low fluid lubricity.
Max. pressure (continuous) : 280 barMax. speed (continuous)M5AS* 006 and 010 ................................................... : 5000 rpmM5AS* 012 and 016 ................................................... : 3800 rpmM5AS* 018 ................................................................. : 3300 rpmM5AS* 023 and 025 ................................................... : 2800 rpm
The high starting torque efficiency of the vane type motors allows them to start under high load without pressure overshoots, jerks and high instantaneous horsepower loads.
This 12 vane type motor exhibits a very low torque ripple (typical ± 1,5%), even at low speeds.
The vane, rotor and cam ring are pressure balanced to increase life over the full speed range. Double lip vanes reduce the sensitivity to fluid pollution.
Our precise manufacturing allows any component to be interchan-geable. Rotating groups may be easily replaced to renew the motor or change the displacement to suit altered requirements for speed or torque.
The M5AS and M5ASF externally drained, are available in three types of rotation : bi-directional, clockwise, counter-clockwise.
The uni-directional M5AS, M5ASF are designed with an internal valve that allows smooth dynamic braking, with a very simple hydraulic circuit and without risk of motor cavitation.
The M5AS, M5ASF motors have a stiff tapered or cylindrical keyed shaft and a high load capacity double ball bearing allow the direct mounting on shaft (like a fan for example).
For applications with motors in series or with high back pressure, please contact Parker.
lOW nOISe MOTOr
HIgH PerFOrManCe MOTOr
HIgH STarTIng TOrQUe
lOW TOrQUe rIPPle
lOng lIFeTIMe
InTerCHangeaBle rOTaTIng grOUPS
rOTaTIOn anD DraIn
CrOSS POrT CHeCK ValVe
MOUnTIng
general characteristics
4
Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA
Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane Motors
5
DescriptionCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
4 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
Description
• The motor shaft is driven by the rotor. Vanes, closely fitted into the rotor slots move radially to seal against the cam ring. The ring has two major and two minor radial sections joined by transitional sections called ramps. These contours and the pressures exposed to them are balanced diametrically.
• Light springs urge the vanes radially against the cam contour assuring a seal at zero speed so that the motor can develop starting torque. The springs and pins are assisted by centrifugal force at higher speeds. Radial grooves and holes through the vanes equalize radial hydraulic forces on the vanes at all times. Fluid enters and leaves the motor cartridge through opening in the side plates at the ramps. Each motor port connects to two diametrically opposed ramps. Pressurized fluid entering at Port A torques the rotor clockwise. The rotor transports it to the ramp openings wich connect to Port B from wich it returns to the low pressure side of the system. Pressure at Port B torques the rotor counter-clockwise.
• The rotor is separated axially from the sideplate surface by the fluid film. The front sideplate is clamped against the cam ring by the pressure, maintains optimum clearance as dimensions change with temperature and pressure. A 3-way shuttle valve in the sideplate causes clamping pressure in Port A or B, whichever is the highest.
• Materials are chosen for long life efficiency. The vanes, rotor and cam ring are made out of hardened high alloy steels. Cast semi-steel side-plates are chemically etched to have a fine crystalline surface for good lubrification at start-up.
OPeraTIOn - SIngle CarTrIDge
Major arc where fluid works to push vane.
Ramp (port A) with vane moving inward by CW rotation.
The cam ring is interchangeable with others of different displacement. It has lub coating on inner surface.
The rotor is of through-hardened high alloy steel.
The rotation is changed by reversing the flow.
The side grooves and radial holes causeundervane and overvane pressure to be equal.
Minor arc where vane works to seal inlet pressure from outlet port.
Ramp (port B) with vane moving outward by CW rotation.
The floating sideplate contains a shuttle valve wich passes a higher pressure signal to the
clamping area.
The cartridge is a replaceable assembly including the cam ring, rotor, vanes and springs.
M5aSFM5aS
Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
4 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
Description
• The motor shaft is driven by the rotor. Vanes, closely fitted into the rotor slots move radially to seal against the cam ring. The ring has two major and two minor radial sections joined by transitional sections called ramps. These contours and the pressures exposed to them are balanced diametrically.
• Light springs urge the vanes radially against the cam contour assuring a seal at zero speed so that the motor can develop starting torque. The springs and pins are assisted by centrifugal force at higher speeds. Radial grooves and holes through the vanes equalize radial hydraulic forces on the vanes at all times. Fluid enters and leaves the motor cartridge through opening in the side plates at the ramps. Each motor port connects to two diametrically opposed ramps. Pressurized fluid entering at Port A torques the rotor clockwise. The rotor transports it to the ramp openings wich connect to Port B from wich it returns to the low pressure side of the system. Pressure at Port B torques the rotor counter-clockwise.
• The rotor is separated axially from the sideplate surface by the fluid film. The front sideplate is clamped against the cam ring by the pressure, maintains optimum clearance as dimensions change with temperature and pressure. A 3-way shuttle valve in the sideplate causes clamping pressure in Port A or B, whichever is the highest.
• Materials are chosen for long life efficiency. The vanes, rotor and cam ring are made out of hardened high alloy steels. Cast semi-steel side-plates are chemically etched to have a fine crystalline surface for good lubrification at start-up.
OPeraTIOn - SIngle CarTrIDge
Major arc where fluid works to push vane.
Ramp (port A) with vane moving inward by CW rotation.
The cam ring is interchangeable with others of different displacement. It has lub coating on inner surface.
The rotor is of through-hardened high alloy steel.
The rotation is changed by reversing the flow.
The side grooves and radial holes causeundervane and overvane pressure to be equal.
Minor arc where vane works to seal inlet pressure from outlet port.
Ramp (port B) with vane moving outward by CW rotation.
The floating sideplate contains a shuttle valve wich passes a higher pressure signal to the
clamping area.
The cartridge is a replaceable assembly including the cam ring, rotor, vanes and springs.
M5aSFM5aS
Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
4 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
Description
• The motor shaft is driven by the rotor. Vanes, closely fitted into the rotor slots move radially to seal against the cam ring. The ring has two major and two minor radial sections joined by transitional sections called ramps. These contours and the pressures exposed to them are balanced diametrically.
• Light springs urge the vanes radially against the cam contour assuring a seal at zero speed so that the motor can develop starting torque. The springs and pins are assisted by centrifugal force at higher speeds. Radial grooves and holes through the vanes equalize radial hydraulic forces on the vanes at all times. Fluid enters and leaves the motor cartridge through opening in the side plates at the ramps. Each motor port connects to two diametrically opposed ramps. Pressurized fluid entering at Port A torques the rotor clockwise. The rotor transports it to the ramp openings wich connect to Port B from wich it returns to the low pressure side of the system. Pressure at Port B torques the rotor counter-clockwise.
• The rotor is separated axially from the sideplate surface by the fluid film. The front sideplate is clamped against the cam ring by the pressure, maintains optimum clearance as dimensions change with temperature and pressure. A 3-way shuttle valve in the sideplate causes clamping pressure in Port A or B, whichever is the highest.
• Materials are chosen for long life efficiency. The vanes, rotor and cam ring are made out of hardened high alloy steels. Cast semi-steel side-plates are chemically etched to have a fine crystalline surface for good lubrification at start-up.
OPeraTIOn - SIngle CarTrIDge
Major arc where fluid works to push vane.
Ramp (port A) with vane moving inward by CW rotation.
The cam ring is interchangeable with others of different displacement. It has lub coating on inner surface.
The rotor is of through-hardened high alloy steel.
The rotation is changed by reversing the flow.
The side grooves and radial holes causeundervane and overvane pressure to be equal.
Minor arc where vane works to seal inlet pressure from outlet port.
Ramp (port B) with vane moving outward by CW rotation.
The floating sideplate contains a shuttle valve wich passes a higher pressure signal to the
clamping area.
The cartridge is a replaceable assembly including the cam ring, rotor, vanes and springs.
M5aSFM5aS
4 5
Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA
Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane MotorsPorts and Hydraulic FluidsCatalogue HY29-0024/UK Hydraulic Motors, Fixed
M5AS/M5ASF, Denison Vane Motors
5 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
Ports and hydraulic fluids
This motor must have a drain line connected to the housing drain connection of sufficient size to prevent back pressure in excess of 3,5 bar, and returned to the reservoir below the surface of the oil as far away as possible from the suction pipe of the pump.
Petroleum base anti-wear R & O fluids (covered by Parker Denison HF-0 and HF-2 specifications).Maximum catalogue ratings and performance data are based on operation with these fluids.
The use of fluids other than petroleum base anti-wear R & O fluids requires that the maximum ratings of the motor will be reduced. In some cases, the minimum replenishment pressure must be increased.
HF-1 : non antiwear petroleum base.HF-4 : water glycols solutions.HF-5 : synthetic fluids.
Max. continuous pressure : 210 bar (HF-1, HF-4, HF-5)Max. speed : 1500 RPM (HF-4, HF-5)
Max. (cold start, low speed and pressure) 2000 mm2/s (cSt)Max. (full speed and pressure) 100 mm2/s (cSt)Optimum (max. lifetime) 30 mm2/s (cSt)Min. (full speed and pressure, HF-1 fluid) 18 mm2/s (cSt)Min. (full speed and pressure, HF-0 & HF-2 fluids) 10 mm2/s (cSt)For cold starts, the motor should operate at low speed and pressure until fluid warms up to an acceptable viscosity for full power operation.
90 min.Higher values extend the range of operating temperatures and lifetime.
Max. fluid temperature (HF-0, HF-1 & HF-2) + 100° CMin. fluid temperature (HF-0, HF-1 & HF-2) - 18° C
The fluid must be cleaned before and during operation to maintain a contamination level of NAS 1638 class 8 (or ISO 19/17/14) or better. Filters with 25 micron (or bet-ter, ß10 ≥ 100) nominal ratings may be adequate but do not guarantee the required cleanliness levels.
Maximum acceptable content of water is :• 0,10 % for mineral base fluids.• 0,05 % for synthetic fluids, crankcase oils, biodegradable fluids.If amount of water is higher, then it should be drained off the circuit.
exTernal DraIn
reCOMMenDeD FlUIDS
aCCePTaBle alTernaTe FlUIDS
VISCOSITY
VISCOSITY InDex
TeMPeraTUre
FlUID CleanlIneSS
WaTer COnTaMInaTIOn In FlUID
Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
5 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
Ports and hydraulic fluids
This motor must have a drain line connected to the housing drain connection of sufficient size to prevent back pressure in excess of 3,5 bar, and returned to the reservoir below the surface of the oil as far away as possible from the suction pipe of the pump.
Petroleum base anti-wear R & O fluids (covered by Parker Denison HF-0 and HF-2 specifications).Maximum catalogue ratings and performance data are based on operation with these fluids.
The use of fluids other than petroleum base anti-wear R & O fluids requires that the maximum ratings of the motor will be reduced. In some cases, the minimum replenishment pressure must be increased.
HF-1 : non antiwear petroleum base.HF-4 : water glycols solutions.HF-5 : synthetic fluids.
Max. continuous pressure : 210 bar (HF-1, HF-4, HF-5)Max. speed : 1500 RPM (HF-4, HF-5)
Max. (cold start, low speed and pressure) 2000 mm2/s (cSt)Max. (full speed and pressure) 100 mm2/s (cSt)Optimum (max. lifetime) 30 mm2/s (cSt)Min. (full speed and pressure, HF-1 fluid) 18 mm2/s (cSt)Min. (full speed and pressure, HF-0 & HF-2 fluids) 10 mm2/s (cSt)For cold starts, the motor should operate at low speed and pressure until fluid warms up to an acceptable viscosity for full power operation.
90 min.Higher values extend the range of operating temperatures and lifetime.
Max. fluid temperature (HF-0, HF-1 & HF-2) + 100° CMin. fluid temperature (HF-0, HF-1 & HF-2) - 18° C
The fluid must be cleaned before and during operation to maintain a contamination level of NAS 1638 class 8 (or ISO 19/17/14) or better. Filters with 25 micron (or bet-ter, ß10 ≥ 100) nominal ratings may be adequate but do not guarantee the required cleanliness levels.
Maximum acceptable content of water is :• 0,10 % for mineral base fluids.• 0,05 % for synthetic fluids, crankcase oils, biodegradable fluids.If amount of water is higher, then it should be drained off the circuit.
exTernal DraIn
reCOMMenDeD FlUIDS
aCCePTaBle alTernaTe FlUIDS
VISCOSITY
VISCOSITY InDex
TeMPeraTUre
FlUID CleanlIneSS
WaTer COnTaMInaTIOn In FlUID
6
Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA
Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane Motors
7
Motor SelectionCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
6 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
Motor Selection
0,85 x >
10,6 > 8,7 kW
2a.
Vi = = = 13,8 cm3/rev
3a. Choose motor from Vi immediately greaterM5AS* 016 : Vi = 16,0 cm
3/rev
4a. Check theoretical motor pressure
D p = = = 216 bar
Torque loss at this pressure = 3,0 Nm(See page 9)Calculate real pressure
D peff. = = = 228 bar
5a. Flow loss at this pressure : 3,5 l/min(See page 9)Real flow used by the motor :Qeff. = 30 - 3,5 = 26,5 l/min
6a. Real speed of the motor :
neff. = = = 1656 rpm
Real performancesVi = 16,0 cm
3/revneff. = 1656 rpmT = 55 Nm.D peff. = 228 bar
0.85 x >
2b.
Vi = = = 20,0 cm3/rev
3b. Choose motor from Vi immediately smallerM5AS* 018 : Vi = 18,0 cm
3/rev
4b. Check theoretical motor pressure withT = 55 Nm
D p = = = 192 bar
Torque loss at this pressure = 3,3 Nm(See page 9)Calculate real pressure
D peff. = = = 204 bar
5b. Flow loss at this pressure : 4 l/min(See page 9)Real flow used by the motor :Qeff. = 30 - 4 = 26,0 l/min
6b. Real speed of the motor:
neff. = = = 1444 rpm
Real performancesVi = 18,0 cm
3/revneff. = 1444 rpmM = 55 Nm.D peff. = 204 bar
Q x p 600
1000 x 30 1500
Motor performances requiredTorque ....................... T [Nm.] 55Speed ....................... n [rpm] 1500Pump available data Flow .......................... Q [l/min] 30D Pressure ................ D p [bar] 250
FlUID POWer FOrMUlaS
Volumetric efficiency
Mechanical efficiency
Fluid motor speed rpm
Fluid motor torque N.m
Fluid motor power kW
1. Check if available power is greater than required power (0.85 estimated overall efficiency).
T x p x n30 x 1000
2. Two ways of calculation : Calculate Vi from T required torque, or from Q available flow.
30 x 250 600
55 x p x 1500 30 x 1000
20 x p x T p
20 x p x 55 250
1000 x Q n
20 x p x T Vi
20 x p x 55 16,0
20 x p x (T + Tl) Vi
20 x p x 58 16,0
Qeff. x 1000 Vi
26,5 x 1000 16,0
20 x p x T Vi
20 x p x 55 18,0
20 x p x (T + Tl) Vi
20 x p x 58,3 18,0
Qeff. x 1000 Vi.
26,0 x 1000 18,0
Speed [rpm]Displacement [cm3/rev]Pressure [bar]Flow rate [l/min]Leakage [l/min]Torque [Nm]Torque loss [Nm]
1 total leakage x 1000 speed x displacement
torque loss x 20 x p D pressure x displacement
1000 x flow rate x volumetric eff. displacement
D pressure x displacement x mech. eff. 20 x p
speed x displacement x D pressure x overall eff. or 600 000
1 +
1 -
torque x speed x 20 x p 600 000
6 7
Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA
Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane MotorsPerformance DataCatalogue HY29-0024/UK Hydraulic Motors, Fixed
M5AS/M5ASF, Denison Vane Motors
7 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
Performance Data
SeriesTheoretical
Displacement Vi
Theoreticaltorque
Theoretical powerat 100 rpm
Typical dataat 2000 rpm - 280 bar
cm3/rev n.m/bar kW/bar n.m kW
M5aM5aSM5aSF
6,3 0,100 0,0011 24,4 5,110,0 0,159 0,0017 40,8 8,612,5 0,199 0,0021 52,0 10,916,0 0,255 0,0027 67,6 14,218,0 0,286 0,0030 75,8 15,923,0 0,366 0,0038 98,4 20,425,0 0,398 0,0042 107,4 22,5
STarTIng PerFOrManCeS
PerMISSIBle SHaFT lOaDS
Mounting flange Threaded port a Threaded port B Threaded drain port Shaft end
M5a Uni-rotational 2-bolts
ISO 3019-2 80 A2 HW
M22 x 1,5 M27 x 2 M12 x 1,5
Taper 1/5Keyed ISO G20N
M5a Bi-rotational
M22 x 1,5 M12 x 1,5
M5aS Uni-rotational 2-bolts
SAE AJ744
SAE 10 - (7/8"-14 UNF)1/2" BSPP
SAE 12 - (1.1/16"-12 UNF)3/4" BSPP
SAE 6 - (9/16" -18 UNF)1/4" BSPP
Taper SAE BKeyed SAE B
Taper 1/5Keyed ISO G20NM5aS
Bi-rotationalSAE 12 - (1.1/16"-12 UNF)
3/4" BSPPSAE 6 - (9/16"-18 UNF)
1/4" BSPP
M5aSF Uni-rotational
2-boltsØ 101,6 h8cartridge /
outrigger bearing version
M22 x 1,5SAE 10 - (7/8"-14 UNF)
1/2" BSPP
M27 x 2SAE 12 - (1.1/16"-12 UNF)
3/4" BSPP
M12 x 1,5SAE 6 - (9/16"-18 UNF)
1/4" BSPPTaper SAE BKeyed SAE B
Taper 1/5Keyed ISO G20NM5aSF
Bi-rotational
M22 x 1,5SAE 12 - (1.1/16"-12 UNF)
3/4" BSPP
M12 x 1,5SAE 6 - (9/16"-18 UNF)
1/4" BSPP
Theoretical lifetime [106 rev] : L10
Theoretical lifetime [Hours] : L10H = x L10
Example of theoretical lifetime calculationAxial load Fa = 1000 NRadial load Fr = 500 NMotor speed N = 1500 rpm
L10 = 2000 [106 rev] (See Curve)
L10H = x 2000 L10H = 22 221 hours.
16 666N [min-1]
16 666 1500
Typical data at 24 cSt @ 45° C Maximum cross flow 100 bar : 0,6 l/min 200 bar : 7,4 l/min 280 bar : 8,9 l/min
0
500
1000
1500
2000
2500
0 500 1000 1500 2000 2500 3000
Fa (N)
Fr
(N)
L10 = 250L10 = 500L10 = 1000L10 = 2000
Axial load Fa [N]
Theoretical lifetime [106 rev]
Rad
ial l
oad
Fr [N
]
x x
Fr
Fa
8
Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA
Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane Motors
9
Max RatingsCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
8 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
Max ratingsMax ratings M5AS 010 & 006
0
50
100
150
200
250
300
0 1000 2000 3000 4000 5000 6000 7000
Operating speed n (RPM)
Pres
sure
p (b
ar)
continuous
intermittent
Max ratings M5AS 016 & 012
0
50
100
150
200
250
300
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
Operating speed n (RPM)
Pres
sure
p (b
ar)
continuous
intermittent
Max ratings M5AS 018
0
50
100
150
200
250
300
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Operating speed n (RPM)
Pres
sure
p (b
ar)
continuous
intermittent
D:\Catalogues Vente\M5ASVente\Anglais\Limitations M5AS.xls 18/02/2010
Max ratings M5AS 025 & 023
0
50
100
150
200
250
300
0 500 1000 1500 2000 2500 3000 3500
Operating speed n (RPM)
Pres
sure
p (b
ar)
continuous
intermittent
006 - 010
012 - 016
018
023 - 025
Operating speed n [rpm]
Operating speed n [rpm]
Operating speed n [rpm]
Operating speed n [rpm]
Pre
ssur
e p
[bar
]P
ress
ure
p [b
ar]
Pre
ssur
e p
[bar
]P
ress
ure
p [b
ar]
- These are running condition limits; for starting performances see page 7.- Typical curves, at 24 cSt @ 45° C.- For higher specifications or for operating speed under < 100 rpm, please consult us.
Continuous Intermittent
Continuous Intermittent
Continuous Intermittent
Continuous Intermittent
8 9
Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA
Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane MotorsTechnical Data
Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
9 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
Technical data
OVerall leaKage (internal + external) TOrQUe lOSSfuite totale M5A 010 @1500 tr/min
1,0
2,0
3,0
4,0
5,0
6,0
- 50 100 150 200 250
p (bar)
fuite
tota
le (
l/min
)
13 cSt26 cSt50 cSt
fuite totale M5A 023 @1500 tr/min
1,0
2,0
3,0
4,0
5,0
6,0
7,0
8,0
9,0
50 100 150 200 250
p (bar)
fuite
tota
le (
l/min
)
13 cSt26 cSt50 cSt
fuite totale M5A 012 @1500 tr/min
1,0
2,0
3,0
4,0
5,0
6,0
7,0
8,0
- 50 100 150 200 250
p (bar)
fuite
tota
le (
l/min
)
13 cSt26 cSt50 cSt
fuite totale M5A 025 @1500 tr/min
1,0
2,0
3,0
4,0
5,0
6,0
7,0
8,0
9,0
10,0
- 50 100 150 200 250
p (bar)
fuite
tota
le (l
/min
)
13 cSt26 cSt50 cSt
perte de couple M5A 010 @1500 tr/min
0,5
1,0
1,5
2,0
2,5
3,0
3,5
- 50 100 150 200 250
p (bar)
pert
e de
cou
ple
(Nm
)
13 cSt26 cSt50 cSt
perte de couple M5A 018 @1500 tr/min
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
- 50 100 150 200 250
p (bar)
pert
e de
cou
ple
(Nm
)
13 cSt26 cSt50 cSt
perte de couple M5A 012 @1500 tr/min
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
- 50 100 150 200 250
p (bar)
pert
e de
cou
ple
(Nm
)
13 cSt26 cSt50 cSt
perte de couple M5A 023 @1500 tr/min
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
50 100 150 200 250
p (bar)
pert
e de
cou
ple
(Nm
)
13 cSt26 cSt50 cSt
Pressure p [bar]
Pressure p [bar]
Pressure p [bar]
Pressure p [bar]
Pressure p [bar]
Pressure p [bar]
Pressure p [bar]
Pressure p [bar]
Ove
rall
leak
age
Qlo
ss [l
/min
]O
vera
ll le
akag
e Q
loss
[l/m
in]
Ove
rall
leak
age
Qlo
ss [l
/min
]O
vera
ll le
akag
e Q
loss
[l/m
in]
Torq
ue lo
ss T
loss
[Nm
]To
rque
loss
Tlo
ss [N
m]
Torq
ue lo
ss T
loss
[Nm
]To
rque
loss
Tlo
ss [N
m]
M5A* - 006 and 010@ n = 1500 rpm
M5A* - 006 and 010@ n = 1500 rpm
M5A* - 012 and 016 @ n = 1500 rpm
M5A* - 012 and 016 @ n = 1500 rpm
M5A* - 018 @ n = 1500 rpm
M5A* - 018 @ n = 1500 rpm
M5A* - 023 and 025 @ n = 1500 rpm
M5A* - 023 and 025 @ n = 1500 rpm
10
Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA
Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane Motors
11
Technical DataCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
10 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
nOISe leVelM5AS 025 Noise Level M5AS 025
50
55
60
65
70
75
80
0 50 100 150 200 250 300Pressure p (bar)
LP N
oise
leve
l [dB
(A)]
500 RPM
1000 RPM
1500 RPM
2000 RPM
500 rpm 1000 rpm 1500 rpm 2000 rpm
Lp. N
oise
leve
l [db
(A)]
1m IS
O 4
412
Pressure p [bar]
Technical data
A B
Uni-rotationnel+ Anti-starve
OPTIOn FOr M5aS - M5aSF UnI-rOTaTIOnal MOTOrS : anTI STarVe ValVe
An anti-starve check valve can be screwed directly onto the B port of the uni-rotational motors, to ensure the minimum replenishment pressure during deceleration phases of high inertia systems (i.e. fan drive).
MInIMUM rePlenISHMenT PreSSUreDUrIng DeCeleraTIOn
Minimum Outlet port pressure for uni-rotationnal motors
Oil Azolla ZS32 T=45°C (26 cSt)
0
1
2
3
4
5
6
7
0 10 20 30 40 50 60 70 80 90 100Q [l/min]
P [b
ar]
Pre
ssur
e p
[bar
] Abs
olut
e
B g A [l/min]
ISO VG 32 @ 45°C
The hydraulic circuit should be designed in a way that when switching off the hydraulic motor, it remains supplied with fluid, without risk of cavitation (anti-cavitation valve may be needed).Uni rotational M5AS* Motors are fitted with an internal anti-cavitation valve.
necessary pressure [bar absolute] at B port of M5aS* uni-rotational during deceleration
View from shaft end : CW rotation A = inlet B = outlet CCW rotation A = outlet B = inlet
BI-rOTaTIOnal (n)
r Or l rOTaTIOn new rotation concept - (Patent pending) :
View from shaft end : CW or CCW rotations A = inlet B = outlet
R or L rotation are featuring a new internal concept where A is always “in” and B is always “out”.
A BA B A BA B+lennoitator-inUlennoitator-inUlennoitator-iB
LP proportionnalUni-rotationnel + LP
A BA B A BA B+lennoitator-inUlennoitator-inUlennoitator-iB
LP proportionnalUni-rotationnel + LP
with pressure relief valvewith prop. pressure
relief valve
Parker DT series check valves
Ex : for SAE 12 treads DT - 750 - MOMF - 65 DT - 75 - MOMS - 65
M5AS - 025
F L O W
10 11
Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA
Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane MotorsM5AS - Ordering CodeCatalogue HY29-0024/UK Hydraulic Motors, Fixed
M5AS/M5ASF, Denison Vane Motors
11 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
M5AS - Ordering code
DRAINA
B
DRAIN
BA
DRAIN
B A
DRAINB
A
DRAIN A
B01 02 03 04
DrainDrain
DrainDrain
Drain
1 2 3 4
end cap = 0
01 02 03 04
A BDRAIN
DRAIN DRAIN DRAINDRAINA B
B
A
B A
A
B
1 2 3 4
Drain Drain Drain Drain
Drain
end cap = 1
Model no. M5aS - 018 - 1 n 0 2 - a 1 W - P21
Model no. M5aSF - 018 - 1 n 0 2 - a 1 W - P21
M5a series - ISO 3019-2Mounting flange 80 A2 SWM5aS series - SAE A 2-boltsJ744 mounting flange
Cam ringVolumetric displacement (ml/rev)006 = 6,3 018 = 18,0010 = 10,0 023 = 23,0012 = 12,5 025 = 25,0016 = 16,0
Type of shaft M5aS1 = Taper (Sae B)2 = Keyed (SAE B)Type of shaft M5a or M5aS 5 = Taper 1/56 = Keyed (ISO G20N)
Direction of rotation (shaft end view)R = Clockwise (with anti-cavitation check valve)L = Counter-clockwise (with anti-cavitation check valve)N = Bi-rotational (without anti-cavitation check Valve)
end cap type0 = with opposite ports1 = with side ports
Porting combination(See table)
M5aSF - 2-bolts flangeØ 101,6 h8
Cam ringVolumetric displacement (ml/rev)006 = 6,3 018 = 18,0010 = 10,0 023 = 23,0012 = 12,5 025 = 25,0016 = 16,0
Type of shaft1 = Taper (Sae B)2 = Keyed (SAE B)5 = Taper 1/56 = Keyed (ISO G20N)
Direction of rotation (shaft end view)R = Clockwise (with anti-cavitation check valve)L = Counter-clockwise (with anti-cavitation check valve)N = Bi-rotational (without anti-cavitation check Valve)
end cap type0 = with opposite ports1 = with side ports
Porting combination(See table)
Modifications or special optionEx. : P21 = Proportional pressure relief valveset at 210 bar at 1000 rpm
end cap variables
M5a bi-rotational seriesCode A & B ports Drain port
Y Metric threadM22 x 1,5Metric thread
M12 x 1,5
M5a uni-rotational seriesCode A port B port Drain port
Y Metric threadM22 x 1,5Metric thread
M27 x 2Metric thread
M12 x 1,5
M5aS bi-rotational seriesCode A & B ports Drain Port
W Sae 12 thread1.1/16"-12 UnFSae 6 thread9/16"-18 UnF
Z 3/4" BSPP 1/4" BSPP
M5aS uni-rotational seriesCode A port B port Drain port
W Sae 10 thread7/8"-14 UnFSae 12 thread1.1/16"-12 UnF
Sae 6 thread9/16"-18 UnF
Z 1/2" BSPP 3/4" BSPP 1/4" BSPP
Seal class1 = S1 BUNA N5 = S5 - VITON®
Design letter
Modifications or special optionEx. : P21 = Proportional pressure relief valveset at 210 bar at 1000 rpm
end cap variables
M5aSF bi-rotational seriesCode A & B ports Drain port
Y Metric threadM22 x 1,5Metric thread
M12 x 1,5
W Sae 12 thread1.1/16"-12 UnFSae 6 thread9/16"-18 UnF
Z 3/4" BSPP 1/4" BSPP
M5aSF uni-rotational seriesCode A port B port Drain port
Y Metric threadM22 x 1,5Metric thread
M27 x 2Metric thread
M12 x 1,5
W Sae 10 thread7/8"-14 UnFSae 12 thread1.1/16"-12 UnF
Sae 6 thread9/16"-18 UnF
Z 1/2" BSPP 3/4" BSPP 1/4" BSPP
Seal class1 = S1 BUNA N5 = S5 - VITON®
Design letter
Preferred types are printed in bold.
12
Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA
Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane Motors
13
M5A - M5AS - DimensionsCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
12 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
M5A - M5AS - Dimensions Motor with side ports
Weight : 12,2 kg
TH
RE
AD
ED
DR
AIN
PO
RT
:2:
SA
E 6
3:
M12
x 1
,5
4: 1
/4"
BS
PP
Mou
ntin
g to
rque
100
N.m
Ø 22,220
-0.25
Pre
ssur
e re
lief v
alve
12
14 M x 1,5
Ø 20-0.065-0.117 �
2
TH
RE
AD
ED
PO
RT
SW
: SA
E 1
2 Y:
M22
x 1
,5
Z: 3
/4"
BS
PP
83,8
4 x
6 ke
y
110
55
55
113,4
15,8
8
3,45
6,35
key
squ
are
Ø 4
47,7
"A"
INLE
T T
HR
EA
DE
D P
OR
TW
: SA
E 1
0 Y:
M22
x 1
,5
Z: 1
/2"
BS
PP
"B"
OU
TLE
T T
HR
EA
DE
D P
OR
TW
: SA
E 1
2 Y:
M27
x 2
Z
: 3/4
" B
SP
P
95
Un
i-ro
tati
on
al ve
rsio
n58,6
7+0
.5 0M
5A:
M5A
S: 6
.4
Ø 82,550-0.05 M5AS: �
M5A: � Ø 80 h8
10
5,5
13
0,4
�Ø 11(2 places)
134,87
41,5 28
,6
65,4
118,
2
151,
6
28,6
19,2
8
44
8 MKey
squ
are
6h9
28
16
Ø 20 �j7
22,5
8
41
8 M
16
23,5
Ø 22,2+0.0250 �ke
y sq
uare
6,3
5
24,94Maxi
24 V
DC
coi
l to
be
conn
ecte
d w
ith
Deu
tsch
DT
06-2
S c
onne
ctor
Pro
port
iona
l pre
ssur
ere
lief v
alve
Sha
ft c
ode
5K
eyed
tape
r 1:
5
Sha
ft c
ode
1S
AE
B -
J74
4 (m
odifi
ed)
Tape
r 12
5:10
00
Sha
ft c
ode
2S
AE
B k
eyed
Sha
ft c
ode
6IS
O G
20N
key
ed
12 13
Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA
Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane MotorsM5A - M5AS - DimensionsCatalogue HY29-0024/UK Hydraulic Motors, Fixed
M5AS/M5ASF, Denison Vane Motors
13 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
TH
RE
AD
ED
DR
AIN
PO
RT:
2: S
AE
6
3: M
12 x
1,5
4:
1/4
" B
SP
P
Mou
ntin
g to
rque
100
N.m
Ø 22,220
-0.25
12
14 M x 1,5
20-0.065-0.117 Ø �
2
Sha
ft c
ode
5K
eyed
tape
r 1:
5
TH
RE
AD
ED
PO
RT
SW
: SA
E 1
2 Y:
M22
x 1
,5
Z: 3
/4"
BS
PP
4 x
6 ke
y
110
55
55
15,8
8
3,45
6,35
key
squ
are
�Ø
4
47,7
58,6
7+0
.5 0M
5A:
M5A
S: 6
.4
82,550-0.05 M5AS: Ø
M5A: Ø 80 h8
105,
5
130,
4
�Ø 11(2 places)
39 28,
6
65,4
120,
7
130,
5
73 80
137,
7
Uni-r
ota
tional v
ers
ion
"A"
INLE
T T
HR
EA
DE
D P
OR
TW
: SA
E 1
0 Y:
M22
x 1
,5
Z: 1
/2"
BS
PP
"B"
OU
TLE
T T
HR
EA
DE
D P
OR
TW
: SA
E 1
2 Y:
M27
x 2
Z:
3/4
" B
SP
P
Pre
ssur
e re
lief v
alve
Pro
port
ionn
al p
ress
ure
relie
f val
ve
109
28,6
8
44
8 MKey
squ
are
6 h9
28
16
Ø 20 �j7
22,5
8
41
8 M
16
23,5
22,2+0.0250 �ke
y sq
uare
6,3
5
24,94Maxi
24 V
DC
coi
l to
be
conn
ecte
d w
ith
Deu
tsch
DT
06-2
S c
onne
ctor
Sha
ft c
ode
1S
AE
B -
J744
(mod
ified
)Ta
per 1
25:1
000
Sha
ft c
ode
2S
AE
B k
eyed
Sha
ft c
ode
6IS
O G
20N
key
ed
M5A - M5AS - Dimensions Motor with opposite ports
Weight : 11,2 kg
14
Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA
Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane Motors
15
M5ASF - DimensionsCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors
14 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
M5ASF - Dimensions Motor with side ports
Weight : 11,5 kg
TH
RE
AD
ED
DR
AIN
PO
RT
:2:
SA
E 6
3:
M12
x 1
,5
4: 1
/4"
BS
PP
Mou
ntin
g to
rque
100
N.m
19
Ø 101,6 �h8
12,9
12
56,5
7,4
36
Ø 22,22
0-0.25 �
68
59
Pre
ssur
e re
lief v
alve
2,4
19,2
44,9
12
14 M x 1,5
Ø 20-0.065-0.117 �
2
Ø 22,2+0.0250 �
24,94 Maxi
23,5
key
squa
re 6
,35
1,6
33
TH
RE
AD
ED
PO
RT
SW
: SA
E 1
2 Y
: M22
x 1
,5
Z: 3
/4"
BS
PP
83,8
4 x
6 ke
y
Pro
port
iona
l pre
ssur
e re
lief v
alve
67,2
110
55
55
113,4
146
73
162,
74
81,3
7
�Ø 14,3
134,9
15,8
8
3 , 45
6,35
key
squ
are
�Ø
4
47,7
"A"
INLE
T T
HR
EA
DE
D P
OR
TW
: SA
E 1
0 Y
: M22
x 1
,5Z
: 1/2
" B
SP
P
"B"
OU
TLE
T T
HR
EA
DE
D P
OR
TW
: SA
E 1
2 Y
: M27
x 2
Z
: 3/4
" B
SP
P
100,
6
95
95
Un
i-ro
tati
on
al V
ers
ion
key
squa
re 6
h9
Ø 20 �j7
28
M8
16
M8
16
22,5
1,6
36
24 V
DC
coi
l to
be
conn
ecte
d w
ith
Deu
tsch
DT
06-2
S c
onne
ctor
Shaft
code 1
SA
E B
- J
744
(mod
ified
)Ta
per
125:
1000
Shaft
code 2
SA
E B
key
edS
haft
code 6
ISO
G20
N k
eyed
Shaft
code 5
Key
ed ta
per
1:5
14 15
Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA
Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane MotorsM5ASF - DimensionsCatalogue HY29-0024/UK Hydraulic Motors, Fixed
M5AS/M5ASF, Denison Vane Motors
15 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France
TH
RE
AD
ED
PO
RT
SW
: SA
E 1
2 Y:
M22
x 1
,5
Z: 3
/4"
BS
PP
TH
RE
AD
ED
DR
AIN
PO
RT
:2:
SA
E 6
3:
M12
x 1
,5
4: 1
/4"
BS
PP
Mou
ntin
g to
rque
100
N.m
86,7
19
64,2
Ø 101,6 �h8
80 73
12,9 12
56,5
7,4
36
Ø 22,220-0.25
16 M x 1,5
68
59
Pro
port
iona
l pre
ssur
e re
lief v
alve
109,
4
146
73
162,
74
81,3
711
0
55
Pre
ssur
e re
lief v
alve
110
55
�Ø 14,32,
419
,2
44,9
12
14 M x 1,5
Ø 20-0.065-0.117 �
2
Ø 22,2+0.0250
24,94 Maxi
23,5
key
squa
re 6
,35
138
,5
1,6
33
4 x
6 ke
y
"A"
INLE
T T
HR
EA
DE
D P
OR
TW
: SA
E 1
0 Y:
M22
x 1
,5
Z: 1
/2"
BS
PP
"B"
OU
TLE
T T
HR
EA
DE
D P
OR
TW
: SA
E 1
2 Y:
M27
x 2
Z
: 3/4
" B
SP
P
key
squa
re 6
h9
Ø 20 �j7
28
M8
16
22,5
1,6
36
� Ø 4
15,8
8
6,35
key
squ
are
24 V
DC
coi
l to
be
conn
ecte
d w
ith
Deu
tsch
DT
06-2
S c
onne
ctor
Sha
ft c
ode
5K
eyed
tape
r 1:
5
Uni-ro
tati
onal ve
rsio
nS
haft
code
1S
AE
B -
J74
4 (m
odifi
ed)
Tape
r 12
5:10
00
Sha
ft c
ode
2S
AE
B k
eyed
Sha
ft c
ode
6IS
O G
20N
key
ed
M5ASF - Dimensions Motor with opposite ports
Weight : 10,5 kg
© 2012 Parker Hannifin Corporation, all rights reserved Catalog HY29-0024/US
Parker Hannifin CorporationHydraulic Pump Division14249 Industrial ParkwayMarysville, OH 43040 USAphone 937.644.4532fax 937.642.3639www.parker.com
North AmericaIndustrialUSAChicago RegionNaperville, IL Tel: (630) 964 0796Great Lakes RegionFairlawn, OH Tel: (330) 670 2680Northeast RegionLebanon, NJ Tel: (908) 236 4121Pacific RegionBuena Park, CA Tel: (714) 228 2509Southern RegionAlpharetta, GA Tel: (770) 619 9767CanadaMilton, Ontario Tel: (905) 693 3000
MéxicoToluca, Edo. de México Tel: (52) 72 2275 4200
MobileUSAGlobal Mobile Lincolnshire, IL Tel: (847) 821 1500Central Region Lincolnshire, IL Tel: (847) 821 1500Eastern Region North Canton, OH Tel: (330) 284 3355Midwest Region Hiawatha, IA Tel: (319) 393 1221Southern Region Aledo, TX Tel: (817) 441 1794Western Region Buena Park, CA Tel: (714) 228 2509CanadaMilton, Ontario Tel: (905) 693 3000
MéxicoApodaca, N.L. Tel: (52) 81 8156 6000
TruckUSAEastern Region Cleveland, OH Tel: (440) 519 1125
Western RegionSan Ramon, CA Tel: (925) 735 9573CanadaMilton, Ontario Tel: (905) 693 3000
MéxicoApodaca, N.L. Tel: (52) 81 8156 6000
EuropeAustriaWiener Neustadt Tel: (43) 2622 23501 0 BelgiumNivelles Tel: (32) 67 280 900Czech Republic and SlovakiaKlecany Tel: (420) 284 083 111DenmarkBallerup Tel: (45) 4356 0400FinlandVantaa Tel: (358) 20 753 2500FranceContamine-sur-Arve Tel: (33) 4 50 25 80 25GermanyKaarst Tel: (49) 2131 4016 0GreeceAthensTel: (30) 210 933 6450
HungaryBudapest Tel: (36) 1 220 4155IrelandCounty Dublin, Baldonnell
Tel: (353) 1 466 6370
ItalyCorsico, Milano Tel: (39) 02 45 19 21
The NetherlandsOldenzaal Tel: (31) 541 585000
NorwaySki Tel: (47) 64 91 10 00
PolandWarsaw Tel: (48) 22 57 32400
PortugalLeca da Palmeira Tel: (351) 22 999 7360RomaniaBucharestTel: (40) 21 252 1382
RussiaMoscow Tel: (7) 495 580 9145SloveniaNovo MestoTel: (386) 7 337 6650
Spain Madrid Tel: (34) 91 675 7300
SwedenSpanga Tel: (46) 8 597 95000
UkraineKiev Tel: (380) 44 494 2731United KingdomWarwick, Tel: (44) 1926 317878
Asia PacificAustraliaCastle Hill Tel: (61) 2 9634 7777
ChinaBeijing Tel: (86) 10 6561 0520 Shanghai Tel: (86) 21 5031 2525
Hong KongTel: (852) 2428 8008
IndiaMahape, Navi Mumbai Tel: (91) 22 5613 7081
KoreaSeoul Tel: (82) 2 559 0400
MalaysiaSubang Jaya Tel: (60) 3 5638 1476
New ZealandMt. Wellington Tel: (64) 9 574 1744
JapanTokyo Tel: (81) 3 6408 3900
SingaporeJurong Town Tel: (65) 6 887 6300
TaiwanTaipei Tel: (886) 2 2298 8987
ThailandBangkok Tel: (662) 717 8140
Middle EastUnited Arab EmiratesAbu Dhabi Tel: (971) 2 678 8587
Latin AmericaPan American DivisionMiami, FL Tel: (305) 470 8800
ArgentinaBuenos Aires Tel: (54) 33 2744 4129
BrazilCachoeirinha RS Tel: (55) 51 3470 9144
VenezuelaCaracas Tel: (58) 212 238 5422
AfricaSouth AfricaKempton Park Tel: (27) 11 961 0700