13
Products & Services Catalog Spring 2011

Hy-Test, Inc. Spring Catalog 2011

Embed Size (px)

DESCRIPTION

Products & Serivices Catalog

Citation preview

Page 1: Hy-Test, Inc. Spring Catalog 2011

Products & ServicesCatalog

Spring 2011

Page 2: Hy-Test, Inc. Spring Catalog 2011

Table of ContentsHYDROSTATIC TESTING!! ! ! ! 3

• High Pressure

• Exemption Cylinders

• “S” Modified

• Proof Testing

• Hose Testing

FIRETRACE!! ! ! ! ! ! ! 5• What is FireTrace?

• Applications

• Accessories

PROTEX II! ! ! ! ! ! ! ! 7• Why Protex II

• Applications

• Inspections

INDUSTRIAL FIRE PROTECTION! ! ! 9• CO2

• Paint Booths

• Dip Tanks & Parts Clean

EXTINGUISHERS! ! ! ! ! ! 11• What is an Extinguishers

• Applications

• Sales & Services

GUARDIAN III! ! ! ! ! ! ! 13• What is Guardian III

• Applications

• Accessories!

Page 3: Hy-Test, Inc. Spring Catalog 2011

Hydrostatic Testing is the main stay of our business. We!ve

established numerous relationships with local Fire

Departments and Fire Equipment companies throughout the New

River and Roanoke Valleys. Insuring that their cylinders are tested to all current standards.

Cylinders Tested:

• DOT Exemption Cylinders for Cascade Cylinders

• SCBA Fiber Wrapped

• SCBA Industrial Aluminum

• DOT 3 Series used for Industrial Gases

• DOT 4B Series used as Fire Extinguishers

• DOT Exemption Cylinders for Paintball

• Soft Steel Low Pressure Cylinders used as Fire Extinguishers

Mission:

• Our main goal is providing the New River Valley with timely and professional Fire Protection Services.

Call us today for a price quote or to schedule a time to service your cylinders. Pick up and delivery service is available and walk-ins are always welcome.

Page 4: Hy-Test, Inc. Spring Catalog 2011

! Industrial Cylinders! ! DOT 3 Series < 210 cf! ! ! $15.00! ! DOT 3 Series > 210 cf! ! ! $30.00! Fiber Wrapped! ! DOT Exemption Cylinders! ! $15.00! Fire Extinguishers! ! DOT 4B! ! ! ! ! $ 5.00! ! Non DOT! ! ! ! ! $ 5.00! Fire & Industrial Hoses! ! 1.5” Single Jacket! ! ! $15.00! ! 2.5” Single Jacket! ! ! $20.00! Eddy Current! ! ! ! ! $ 3.50

Hydrostatic Testing

Page 5: Hy-Test, Inc. Spring Catalog 2011

Hy-Test, Inc. 5214 Enterprise Drive Elliston, Va 540-268-2858 www.hytestinc.com

Industrial Fire Suppression

• Cleaning Tanks

• Computer and Server

• CNC Machines

• Dust and Mist Collectors

• Electrical Control Cabinets

• EDM Machines

• Fume Hoods and Cabinets for Laboratories

• Hazardous Material Storage

• Manufacturing Equipment and Processes

• Telecommunications Equipment

• Wind Turbines

Off-Road Vehicles

• Farm Equipment - Harvesters and Pickers

• Heavy Duty Equipment

• Mass Transportation

• Military Vehicle and Aircraft Fire Protection Systems

Direct Release SystemsThe Direct Release System utilizes the Firetrace Detection Tubing as both the fire detection device and the fire suppressant delivery system. The portion of the tube nearest the hottest point of the fire ruptures, forming an effective discharge “nozzle”. The pressure drop in the tube releases the entire content of the cylinder through this nozzle.

Indirect Release SystemsWith the Indirect Release Systems, the Firetrace Detection Tubing is used only as a detection device. The fire suppression agent is delivered via copper tubing, stainless steel tubing or braided hose. Once the tube “bursts”, the suppressant is discharged through strategically placed nozzles within the protected enclosure.

Page 6: Hy-Test, Inc. Spring Catalog 2011

What is FireTrace?! FireTrace is a self-activating suppression system that !reliably ! suppresses fires in seconds. FireTrace can be installed ! in virtually any enclosed space where high-value assets ! are located. Our proprietary polymer tubing will rupture ! when exposed to flame. The detection tubing connects to one ! of our custom engineered valves and cylinders; that contains ! the best fire suppressant agent for a particular hazard.

Applications:! CNC Machines! PLC Cabinets! Engine Compartments! Milling Machines! Control Cabinets! Chemical Storage! Dust Collectors! Fume Hoods!! Wind TurbinesAccessories:! Pressure Switches for Equipment Shutdown! Manual Release Stations! Audible AlarmsServices:! Semi Annual & Annual Inspections per NFPA! Design & Installation Packages Available

FireTrace

Page 7: Hy-Test, Inc. Spring Catalog 2011

Protex II

The Protex Series II Restaurant Fire Suppression System is of the pre-engineered type as defined by NFPA 17A, the standard for Wet Chemical Extinguisher Systems and is designed to provide fire protection for restaurant cooking appliances, hoods and ducts. The System provides automatic actuation and can be manually actuated through a remote Mechanical Pull Station. Upon activation the system discharges a pre-determined amount of agent through a fixed pipe arrangement to the duct, plenum and cooking appliances.

Applications:! Restaurants! ! ! Nursing Homes! Hotels!! ! ! Adult Homes! Schools! ! ! Churches

Services:! Design! ! ! Installation! Renovations! ! ! Inspections

Page 8: Hy-Test, Inc. Spring Catalog 2011

Protex II

Basic Package Protects! 8" Exhaust Hood! 100” Perimeter Duct Opening! 3 Electric Cooking AppliancesBasic Package Includes! L3000 Cylinder and Bracket! MCH2 Mechanical Control Head and Bracket! 210SH (3) Fusible Link Kits! RPSM Remote Pull Station! MSSPDT2 Single Pole Microswitch! 90KBS (5) Corner Pulley! Various Nozzles (5) (depends on appliances)! 306A100 100" SS Cable

! ! $1450.00 plus S&H

Basic Package Does NOT Include! Gas Valve (if needed)! 3/8” Black Iron Pipe! 1/2” EMT Conduit! 3/8” Fittings! Any Installation Material! Permits and Drawings! Labor

Page 9: Hy-Test, Inc. Spring Catalog 2011

Industrial Fire Protection

Special Hazard Fire Suppression Systems are designed (engineered) for a specific application. Many factors impact the design, but all systems are designed to meet NFPA requirements.

Applications! Paint Booths!! Polypropylene Benches! ! Dip Tanks! Parts Clean! ! Fume Hoods!! ! ! Exhaust Ducts

Services! Design! ! Inspections! ! Repairs

Call 540-268-2858 or email [email protected] for more information.

Page 10: Hy-Test, Inc. Spring Catalog 2011

Extinguishers

Elements of Fires! There are three elements that make up a fire. If you want to put a fire out, you need to remove one of the three elements.

! Fuel - Combustible Solids, Liquids or Gases! Oxygen - Reacts with the Fuel! Heat - There must be enough heat to get the fuel source! ! above its Flash Point

Extinguisher Ratings ! ABC Dry Chemical Fire Extinguishers are by far the most common extinguishers found in the home or work place. They can handle all three types (Class) of fires that you would find in the kitchen, workshop, garage or warehouse, etc.

! A - Combustible Solids: Wood, Paper and Cardboard! B - Combustible Liquids: Cooking Oils, Gasoline! C - Electrical Fires

Extinguisher Sizes! Portable extinguishers are also rated for the size of fire they can put out. This rating is expressed as a number from 1 to 40 for Class A fires. 1 to 640 for Class B fires. This rating will be printed on the label: 2A:10B:C The larger the number, the larger the fire of a specific Class, on which the extinguisher can be used. The C on the label indicates that the extinguisher is safe to use on electrical fires.

Page 11: Hy-Test, Inc. Spring Catalog 2011

Extinguishers

Services & Sales

! Refills of Dry Chemical Ext.! ! 2.5# - !! $11.50! ! 5# -! ! $13.05! ! 10# -! ! $27.30! ! 20# -! ! $47.32

! CO2 Extinguisher Refills! ! $1.00 per pound of CO2

! New Extinguishers

! ! 2.5# ABC -! $31.78! ! 5# ABC -! $45.61! ! 10# ABC -! $66.73! ! 20# ABC - ! $138.45

! Hydrostatic Testing! ! DOT 4B -! $5.00! ! Non DOT -! $5.00! ! CO2 Ext. -! $15.00

Page 12: Hy-Test, Inc. Spring Catalog 2011

Guardian III - Residential Fire Protection

What is the Guardian III?! The Guardian III Extinguisher System is totally self-contained within its own enclosure. The entire discharge assembly, including Heat Sensors and Nozzles are held underneath the range hood by magnetic force. While the enclosure mounts easily inside the cabinets located above the stove.! When a stove-top fire occurs, the sensor(s) will activate at a pre-determined temperature, notifying the main CPU board to discharge the extinguisher"s Wet Agent; while simultaneously activating the CPU mounted Alarm. Upon system activation, the Gas or Electricity to the stove is shut off to protect re-ignition of the fire. ! This UL Listed system can also be wired into an existing Alarm Panel to show activation.

Applications! Adult Homes!! Day Cares! Churches! ! Civic Organizations! Dorm Rooms!! Military Base Homes

Page 13: Hy-Test, Inc. Spring Catalog 2011

Guardian III

Basic Package Includes! System Enclosure! Distribution Assembly! Temperature Sensors! 53 oz. Ansulex Suppressant! 3 or 4 Prong Electricity Shutoff! Interconnection Cable! Labor to Install

! ! ! $1750.00 plus S&H

Accessories! Manual Pull Station! Remote Alarm & Strobe Combo! AC/DC 110 Volt Adapter! Wireless Receiver Box! Interface Enclosure Assembly! Gas Shutoff Assembly! Gas Control Box