28
No. 13, Jalan Budiman, Budiman Business Park, Bandar Sungai Long, 43000 Kajang, Selangor, Malaysia. +603 8741 7300 [email protected] facebook.com/AireGardMY AireGard.com HVLS

HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

No. 13, Jalan Budiman,Budiman Business Park,Bandar Sungai Long,43000 Kajang,Selangor, Malaysia.

+603 8741 [email protected]/AireGardMYAireGard.com

HVLS

Page 2: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

Using only use world class, industrial

-grade components and the highest

quality parts to ensure the most efficient,

and reliable fan possible. We offer you

the best-value proposition in the market

from an investment perspective.

Every one of our HVLS fans is

engineered to deliver the smoothest,

most efficient, and most precise airflow

possible. Our fan blades are made from

aviation grade magnalium, making them

stronger and lighter.

3.

THEre’s quality in every inch of airegard HVLS fan

Page 3: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

5.

2 IMPROVE THERMAL COMFORT

1 IMPROVE VENTILATION

3 COST SAVINGS

4 LARGE COVERAGE AREA

Page 4: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

Six series

7.

Page 5: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

9.

Six seriesDRIVETRAIN

Our aerofoil blades are made of aviation

grade magnalium (magnesium alloy) and

finished in fluorocarbon coating to

withstand the toughest environment. It's

unique patented design structure is

further strengthened with 3 vertical

stiffeners within the length of each blade

to avoid structural fatigue.

At the heart of our SIX series, we partner

with market-leading drive automation

manufacturer Lenze's dual stage helical

gearbox for maximum performance and

reliability.

AIRFOIL BLADES

A winglet is attached to a distal end of the

aerofoils to reduce drag and improve

downward lift, creating up to 40% more

air than most of our competitors.

Collaborating with some of the market

leading brands such as Yaskawa and

Danfoss, our frequency driver offers

world class reliability and easy to use

operation for peace of mind.

Made of Aluminium Alloy, our drive hub

(SIX series only) are made using 1500T

Hot Press Forging to ensure maximum

mechanical efficiency.

Control system

AERO WINGLET

Chassis

Page 6: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

11.

Six series

SIX-12 SIX-16 SIX-20 SIX-24

Airfoil with winglet

6

Max. Displacement

BLADES

PERFORMANCE &POWER

Blade style

Blade material Magnalium (Aluminium Alloy) , Carbon Fluorine Treated Surface

Number of blades

Blade diameter

65 kgTotal Hanging Weight

WEIGHT & DIMENSIONS

80 kg 105 kg 120 kg

12 ft (3.6 m) 16 ft (4.9 m) 20 ft (6.1 m) 24 ft (7.3 m)

397,000 CFM 365,000 CFM 428,000 CFM 460,000 CFM

1.1 kW 1.5 kW 1.5 kW 1.5 kW

1.5 HP

2.4 Amps / 415 V

3.5 Amps / 415 V

3.5 Amps / 415 V

3.5 Amps / 415 V

2.0 HP 2.0 HP 2.0 HP

Variable Speed

Max. Power Usage

Equivalent HorsepowerRating

Rated Current

90 RPM 70 RPM 60 RPM 50 RPM

Motor Type MD Series 3 Phase AC Motor (4 poles)

Lenze Automation GmbH, Germany

60 Celcius

MOTOR

Manufacturer

Max. Ambient Temperature for Operation

IP55 (EN60529)Degree of Protection

Gearbox Type

Control Type

GST Series Dual Stage Helical Gearbox

Variable Frequency Drive ( Inverter Drive )

Lenze Drives GmbH, Germany

16-bit Microprocessor Logic , LED Status Display , Built-in Dynamic Braking Transistor

0.97

Yaskawa Electric Corporation, Japan / Danfoss Engineering

375 Nm

DRIVE TRAIN

CONTROLS

Manufacturer

Features

Manufacturer

Max. Torque

Mechanical Efficiency

Cooling System

Standards

Max. Ambient Temperature

for Operation

Integrated Blower Fan

cURus, GOST-R, CCC & UkrSepro

50 Celcius

Standards cURus, GOST-R, CCC & UkrSepro

Sound Level 50 ~ 55 dB

Complete Mounting Kit Included

Optional Extension Lengths Available

Mounting Hardware

INSTALLATION

Drop Extensions

5 Years**WARRANTY

WARRANTY

**Subject to Terms & Conditions.

SIX series

Page 7: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

13.

AAC MODEL

24’ (7.3 m)

20’ (6.1 m)

16’ (4.9 m)

12’ (3.6 m)

SIX-24

SIX-20

SIX-16

SIX-12

210300

400

(mm)

60 65

2-Ă24

210

control box specifications

800 mm

A

EXTENSION TUBESmin. 300 mm ( 1ft )

Six series

Before beginning installation, check that the building structure and fan location meet safety guidelines by confirming the below requirements.

Fans mounted on fabricated I-beams, which are common in steel buildings, could cause the beam to flex and the fan to move during operation.

The fan’s lateral movement must be secured using guy wires if the fan’s extension tube is 1 ft (0.3 m) or longer or if the mounting structure requires it. If the fan is close to any building fixtures it is recommended to secure the fan with guy wires as a safety measure.

The fan must be installed so that it is ≥ 18 ft (6 m) above the finished floor.

Multiple fans must be spaced at a center-to-center distance that is no less than 2.5x the fan diameter.

All fan parts must be ≥ 2 ft (0.6m) from all obstructions. The fan installation area must be free of obstructions such as lights, cables, sprinklers, or other building structure components.

*For specific requirements, please call 1300-88-4273

General guideline

LINE DRAWING

Page 8: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

15.

Six series

Upper Yoke

Drop Tube

M16 Bolts & Nuts

Upper Yoke

Drop Tube

M16 Bolts & Nuts

Mounting Details

4 Nos X M16 X 150 AnchorsConcrete slab/Beam(Min Grade 30)

Upper yoke

Drop tube

Mounting Details To Conrete Beam

4 Nos X M16 X 150 AnchorsConcrete Slab/Beam(Min Grade 30)

Upper yoke

Drop tube

Mounting Details To Square/Rectangular Hollow Section

Square Hollow SectionMin. 100 mm X 100 mm

Thickness Min. 4 mm

Square Hollow SectionMin. 100 mm X 100 mm

Thickness Min. 4 mm

Mounting Details To I-BEAM

Mounting Details To Circular Hollow Section

Top View

Front View

Side View

Upper Yoke

Drop Tube

Circular HollowSection

M16 Bolts & Nuts

Upper Yoke

Circular HollowSection

M16 Bolts & Nuts

Drop Tube

Drop tube

Beam clamp I-beam

Upper yokeSpacer

M16 bolts & Nuts

Drop tube

I-beam

Upper yoke

M16 bolts & Nuts

(mm)

270

150

400

136

8

400

32

170

335

81 97

270

195

170

8

Page 9: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

17.

DC Series

Page 10: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

19.

DC Series

An HVLS fan is only as good as the proven

technology behind it. Together with its

partners, AireGard has adapted brushless

direct drive DC motor to run a HVLS fan.

This motor system, also known as BLDC,

is a breakthrough in HVLS technology;

with only 2 moving parts. The motor is 3

times smaller yet 5 times more powerful

with installation, operation and maintenance

costs all vastly improved to bring savings

to our customers.

SKF BEarings

With SKF bearings increase, CNC

precision engraving, milling processes

and high precision engineering helps to

ensure the stability of the transmission

system and longer lifespan.

DRIVETRAIN

Our aerofoil blades are made of aviation

grade magnalium (magnesium alloy) and

finished in fluorocarbon coating to

withstand the toughest environment. It's

unique patented design structure is

further strengthened with 3 vertical

stiffeners within the length of each blade

to avoid structural fatigue.

AIRFOIL BLADES

A wingtip is attached to a distal end of the

aerofoils to reduce drag and improve

downward lift, creating up to 40% more

air than most of our competitors.

AERO WINGLET

Page 11: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

DC-8 DC-10 DC-12 DC-14

Airfoil with winglet

8

Max. Displacement

BLADES

PERFORMANCE & POWER

Blade style

Blade material Magnalium (Aluminium Alloy) , Carbon Fluorine Treated Surface

Number of blades

Blade diameter

31 kgTotal Hanging Weight

WEIGHT & DIMENSIONS

35 kg 38 kg 41 kg

150 W 300 W 405 W 410 W

Variable Speed

Max. Power Usage

120 RPM 100 RPM 90 RPM 76 RPM

Motor Type Brushless DC Motor (BLDC)

Gearless Direct Drive

MOTOR

Drive Train

Max. Torque

Mechanical Efficiency

84,048 CFM52,618 CFM 106,297 CFM 131,723 CFM

2.0 Amps / 240 V

220 - 240 V / 1 P

Rated Current (Max.)

Input Voltage

8 ft (2.4 m) 10 ft (3.0 m) 12 ft (3.6 m) 14 ft (4.2 m)

22.5 Nm 32.5 Nm 37.5 Nm 42.5 Nm

0.8

Control Type Variable Frequency Drive ( Inverter Drive )

Dual Microprocessor Logic, LED Status Display ,Built-in Dynamic Braking Transistor

Yaskawa Electric Corporation, Japan / Danfoss Engineering

CONTROLS

Features

Manufacturer

Max. Ambient Temperature

for Operation50 Celcius

Complete Mounting Kit Included

Optional Extension Lengths Available

Mounting Hardware

INSTALLATION

Drop Extensions

5 Years**WARRANTY

WARRANTY

**Subject to Terms & Conditions.

60 Celcius

Centrifugal Cooling

< 43 dB

Max. Ambient Temperature for

Operation

Cooling System

Sound Level

IP20Degree of Protection

21.

DC Series

DC series

Page 12: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

23.

DC SeriesADC MODEL

14’ (4.2 m)

12’ (3.6 m)

10’ (3.0 m)

8’ (2.4 m)

DC-14

DC-12

DC-10

DC-8

82.29

201.23

Depend on

the Exntension

Tube Length

A

EXTENSION TUBES

min. 300 mm ( 1ft )

Before beginning installation, check that the building structure and fan location meet safety guidelines by confirming the below requirements.

Fans mounted on fabricated I-beams, which are common in steel buildings, could cause the beam to flex and the fan to move during operation.

The fan’s lateral movement must be secured using guy wires if the fan’s extension tube is 1 ft (0.3 m) or longer or if the mounting structure requires it. If the fan is close to any building fixtures it is recommended to secure the fan with guy wires as a safety measure.

The fan must be installed so that it is ≥ 10 ft (3 m) above the finished floor.

Multiple fans must be spaced at a center-to-center distance that is no less than 2.5x the fan diameter.

All fan parts must be ≥ 2 ft (0.6m) from all obstructions. The fan installation area must be free of obstructions such as lights, cables, sprinklers, or other building structure component.

*For specific requirements, please call 1300-88-4273

General guideline

LINE DRAWING

Page 13: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

25.

Mounting Details

For Concrete Slab

For Rectangular Hollow Section & Circular Hollow Section

Rectangular HollowScetion

4 x M16 Stud & Nuts

4 x M20 Expansion Bolts

2 x M16 Drop-In Anchors &Eys Nuts tied with

M5 Stainless Steel Guy Wire

control box specifications

285 mm Ø 65 mmØ 5 mm

60 mm

80 mm

100 mm

100 mm

185 mm

195 mm185 mm

50 mm

130mm

195mm

70 mm

Ø 65 mm 60 mm 5 mmØ

130 mm

50 mm

185 mm

80 mm

50 mm

40 mm

50 mmØ 25 mm

65 mm

65 mm

65 mmØ 9 mm

Ø 22 mm

DC Series

5663

63

L

150122 x 17

200

(mm)

122

400

140

- 350

11

5663

63

150122 x 17

200

(mm)

122

400

140

- 350

11

Page 14: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

DCb series

27.

Page 15: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

22 ft (6.7 m)20 ft (6.1 m)18 ft (5.5 m)16 ft (4.9 m)

DCB-16 DCB-18 DCB-20 DCB-22

Airfoil with winglet

5

Max. Displacement

BLADES

PERFORMANCE &POWER

Blade style

Blade material Magnalium (Aluminium Alloy) , Carbon Fluorine Treated Surface

Number of blades

Blade diameter

Total Hanging Weight

WEIGHT & DIMENSIONS

Speed

Max. Power Usage

Rated Current (Max.)

Motor Type Brushless DC Motor ( BLDC )

Gearless Direct Drive

210Nm

MOTOR

Drive Train

Max. Torque

0.94Mechanical Efficiency

Control Type Variable Frequency Drive ( Inverter Drive )

Dual Microprocessor Logic, LED Status Display ,Built-in Dynamic Braking Transistor

Yaskawa Electric Corporation, Japan / Danfoss Engineering

CONTROLS

Features

Manufacturer

Max. Ambient Temperature

for Operation50 Celcius

Complete Mounting Kit Included

Optional Extension Lengths Available

Mounting Hardware

INSTALLATION

Drop Extensions

5 Years**WARRANTY

WARRANTY

**Subject to Terms & Conditions.

220 - 240 V / 1P

412,235 CFM 446,823 CFM372,352 CFM345,882 CFM

6.5 Amps / 240 V

6.0 Amps / 240 V

5.5 Amps / 240 V

5.0 Amps / 240 V

Input Voltage

64 kg 68 kg 73 kg 78 kg

60 Celcius

Centrifugal Cooling

39 dBA 38 dBA 40 dBA 39 dBA

Max. Ambient Temperature for

Operation

Cooling System

Sound Level

IP20Degree of Protection

25-60 RPM25-70 RPM25-80 RPM25-100 RPM

900 W800 W700 W600 W

DCB Series

29.

DCb series

Page 16: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

31.

DCb series

Before beginning installation, check that the building structure and fan location meet safety guidelines by confirming the below requirements.

ADC MODEL

22’ (6.7 m)

20’ (6.1 m)

18’ (5.5 m)

16’ (4.9 m)

DCB-22

DCB-20

DCB-18

DCB-16

control box specifications

Fans mounted on fabricated I-beams, which are common in steel buildings, could cause the beam to flex and the fan to move during operation.

The fan’s lateral movement must be secured using guy wires if the fan’s extension tube is 1 ft (0.3 m) or longer or if the mounting structure requires it. If the fan is close to any building fixtures it is recommended to secure the fan with guy wires as a safety measure.

The fan must be installed so that it is ≥ 18 ft (6 m) above the finished floor.

Multiple fans must be spaced at a center-to-center distance that is no less than 2.5x the fan diameter.

All fan parts must be ≥ 2 ft (0.6m) from all obstructions. The fan installation area must be free of obstructions such as lights, cables, sprinklers, or other building structure components.

A

EXTENSION TUBES

min. 300 mm ( 1ft )

210300

400

(mm)

60 65

2-Ă24

210

*For specific requirements, please call 1300-88-4273

General guideline

LINE DRAWING

Page 17: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

33.

DCB series

Upper Yoke

Drop Tube

M16 Bolts & Nuts

Upper Yoke

Drop Tube

M16 Bolts & Nuts

4 Nos X M16 X 150 AnchorsConcrete slab/Beam(Min Grade 30)

Upper yoke

Drop tube

Mounting Details To Conrete Beam

4 Nos X M16 X 150 AnchorsConcrete Slab/Beam(Min Grade 30)

Upper yoke

Drop tube

Mounting Details To Square/Rectangular Hollow Section

Square Hollow SectionMin. 100 mm X 100 mm

Thickness Min. 4 mm

Square Hollow SectionMin. 100 mm X 100 mm

Thickness Min. 4 mm

Mounting Details To I-BEAM

Mounting Details To Circular Hollow Section

Upper Yoke

Drop Tube

Circular HollowSection

M16 Bolts & Nuts

Upper Yoke

Circular HollowSection

M16 Bolts & Nuts

Drop Tube

Drop tube

Beam clamp I-beam

Upper yokeSpacer

M16 bolts & Nuts

Drop tube

I-beam

Upper yoke

M16 bolts & Nuts

Mounting Details

Side View

(mm)

270

195

170Top View

Front View

270

150

400

136

8

400

32

170

335

81 97

8

Page 18: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

35.

PSX Series

Page 19: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

37.

PSX Series

Introducing our latest HVLS fan direct

drive technology; PMSM Motor.

There are some clear advantages to going

with our 3rd Generation HVLS Fan: no

more costly gearbox maintenance visits,

no more oil leakages, no more noisy fans,

etc. Behind the design of our cutting edge

PMSM Motor is a philosophy of sound

engineering and precision manufacturing

that created a drivetrain that not only

offers more power than the competition,

it virtually eliminates all routine power-

train maintenance and yields massive air

flow. The result is an incredibly efficient

and durable fan.

All PSX Series HVLS fans feature a direct

drive, maintenance-free PMSM motor

powertrain. As an incredibly efficient

system, made using ND-60 Neodymium

as permanent magnets, it channels power

directly from the motor to the fan hub.

Our aerofoil blades are made of aviation

grade magnalium (magnesium alloy) and

finished in fluorocarbon coating to

withstand the toughest environment. It's

unique patented design structure is

further strengthened with 3 vertical

stiffeners within the length of each blade

to avoid structural fatigue.

AIRFOIL BLADES

A wingtip is attached to a distal end of the

aerofoils to reduce drag and improve

downward lift, creating up to 40% more

air than most of our competitors.

AERO WINGLETExhilarating performance Carefree Ownership

Zero Routine Powertrain Maintenance

Page 20: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

PSX-18 PSX-20 PSX-24

Airfoil with winglet

5

Max. Displacement

BLADES

PERFORMANCE & POWER

Blade style

Blade material Magnalium (Aluminium Alloy) , Carbon Fluorine Treated Surface

Number of blades

Blade diameter

113 kg 120 kg 135 kgTotal Hanging Weight

WEIGHT & DIMENSIONS

1.8 KW 1.8 KW 1.8 KW

Variable Speed

Max. Power Usage

5 - 70 RPM 5 - 62 RPM 5 - 57 RPM

Motor Type Permanent Magnet Synchronous Motor (PMSM)

Direct Drive Gearless

MOTOR

Drive Train

Max. Torque

Mechanical Efficiency

434,370 CFM381,398 CFM 522,657 CFM

8.0 Amps / 220 V

220 V / 1 P

Rated Current (Max.)

Input Voltage

18 ft (5.5 m) 20 ft (6.1 m) 24 ft (7.3 m)

260 Nm

0.94

Control Type Variable Frequency Drive ( Inverter Drive )

Dual Microprocessor Logic, LED Status Display ,Built-in Dynamic Braking Transistor

Yaskawa Electric Corporation, Japan

CONTROLS

Features

Manufacturer

Max. Ambient Temperature

for Operation50 Celcius

Complete Mounting Kit Included

Optional Extension Lengths Available

Mounting Hardware

INSTALLATION

Drop Extensions

5 Years**WARRANTY

WARRANTY

**Subject to Terms & Conditions.

60 Celcius

Centrifugal Cooling

< 40 dBA

Max. Ambient Temperature for

Operation

Cooling System

Sound Level

IP44Degree of Protection

39.

PSX Series

PSX series

Page 21: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

41.

PSX SeriesAPSX MODEL

24’ (7.3 m)

20’ (6.1 m)

18’ (5.5 m)

PSX-24

PSX-20

PSX-18

EXTENSION TUBES

min. 300 mm ( 1ft )

Before beginning installation, check that the building structure and fan location meet safety guidelines by confirming the below requirements.

Fans mounted on fabricated I-beams, which are common in steel buildings, could cause the beam to flex and the fan to move during operation.

The fan’s lateral movement must be secured using guy wires if the fan’s extension tube is 1 ft (0.3 m) or longer or if the mounting structure requires it. If the fan is close to any building fixtures it is recommended to secure the fan with guy wires as a safety measure.

The fan must be installed so that it is ≥ 10 ft (3 m) above the finished floor.

Multiple fans must be spaced at a center-to-center distance that is no less than 2.5x the fan diameter.

All fan parts must be ≥ 2 ft (0.6m) from all obstructions. The fan installation area must be free of obstructions such as lights, cables, sprinklers, or other building structure component.

*For specific requirements, please call 1300-88-4273

control box specifications

210300

400

(mm)

60 65

2-Ă24

210

General guideline

LINE DRAWING

A

Page 22: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

PSX Series

43.

Upper Yoke

Drop Tube

M16 Bolts & Nuts

Upper Yoke

Drop Tube

M16 Bolts & Nuts

4 Nos X M16 X 150 AnchorsConcrete slab/Beam(Min Grade 30)

Upper yoke

Drop tube

Mounting Details To Conrete Beam

4 Nos X M16 X 150 AnchorsConcrete Slab/Beam(Min Grade 30)

Upper yoke

Drop tube

Mounting Details To Square/Rectangular Hollow Section

Square Hollow SectionMin. 100 mm X 100 mm

Thickness Min. 4 mm

Square Hollow SectionMin. 100 mm X 100 mm

Thickness Min. 4 mm

Mounting Details To I-BEAM

Mounting Details To Circular Hollow Section

Upper Yoke

Drop Tube

Circular HollowSection

M16 Bolts & Nuts

Upper Yoke

Circular HollowSection

M16 Bolts & Nuts

Drop Tube

Drop tube

Beam clamp I-beam

Upper yokeSpacer

M16 bolts & Nuts

Drop tube

I-beam

Upper yoke

M16 bolts & Nuts

Mounting Details

Side View

(mm)

270

195

170Top View

Front View

270

150

400

136

8

400

32

170

335

81 97

8

Page 23: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

DHL , Shah Alam

From cold rooms to multi-tiered racking, one of their biggest challenge is to maintain a comfortable temperature across their massive warehouse. They chose AireGard as their choice of HVLS fans to move air throughout the warehouse, from ceiling to floor and wall to wall, including up and over obstructions such as racking.

SIX Series

45.

One City, USJ SIX Series

The economic challenges of operating an al-fresco retail store dictate smart design, value and comfort for customers – as comfortable customers generally shop longer and spend more. AireGard HVLS are installed in the Garden Boulevards to do just that.

PortFolio

Page 24: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

47.

MPOB, Bandar Baru Bangi SIX Series

The client needed air circulation to combat chemical fumes and stay comfortable. They considered installing air conditioning but the high initial cost and prospect of expensive monthly electric bills turned them off. They installed one 24-ft (7.3-m) diameter SIX-24 to move air throughout the entire space. The fan creates a perceived cooling effect that makes occupants feel up to 10°F (5.6°C) cooler.

Masjid Sultan Abdul Samad, Sepang SIX Series

Masjid Sultan Abdul Samad, also fondly known as KLIA Mosque, is a distinctive landmark among visitors landing at the KL International Airport. With a total ceiling height of more than 50ft, its operator. Malaysia Airport Holdings Bhd knows there is only one way to keep the main prayer hall cool and comfortable – installing AireGard HVLS fans.

PortFolio

Page 25: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

49.

The Gasket Alley, Petaling Jaya DC Series Pos Malaysia , Shah Alam DC SeriesPetrol Heads. Custom motorcycles. Groovy folks. Good vibes. The Gasket Alley is a curated space housing all of the above, with a huge knack for events from time to time. That’s where they also realised the need for cool spaces. They wanted to up the comfort level without compromising their goal of being the greenest auto shop in the business and their choice of solution was to install 2 units of our DC-12 (3.6m) diameter HVLS fans. The hot rods couldn’t have been more cooler.

Facility managers worked with AireGard to create powerful air movement that kept workers cool in this semi air-conditioned facility. The facility installed ten DC-14(4.2-m) fans to help circulate the conditioned air in the plant to eliminate heat pockets for better comfort and even temperature.

PortFolio

Page 26: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

Masjid Gulang-Gulang, Kuala Selangor DC Series

A historical mosque located in the small township of Kuala Selangor. Back in those days, this was the flagship mosque for muslims prayers. Whilst being small, the akward design of the mosque wasn’t particularly built for good airflow. So we put up a 12Ft HVLS DC FAN and it brought life back into this historical mosque.

Honda Service Centre, Kajang DCB SeriesThey needed a way to improve the comfort level of the mechanics working in the service bays, while being operationally efficient and environmentally conscious too. Several different things such as industrial wall fans were tried to bring that heat down and provide comfort but with limited success. The installation, shipment and delivery of the AireGard HVLS fans met all the owner’s expectations, and the fan's performance has drawn rave reviews.

51.

PortFolio

Page 27: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

SMK St Mary, Kuala Lumpur DCB SeriesAmway Malaysia HQ, Petaling Jaya DCB Series

The state-of-the-art warehouse of the direct selling giant was well equipped with most advanced features but is weak on ventilation system. AireGard's quiet effective gearless and silent HVLS fans was brought in to relieve the stagnant air by improving air circulation in the warehouse’s sorting and unloading area - where most of their employees are.

For many years, the school officials unsuccessfully tried to cool down the non-air conditioned multipurpose hall with box fans, floor fans and a variety of inefficient air movers. Excessive heat made teachers and students uncomfortable at assemblies. With the full support and confidence of the board of governors, the school chose AireGard HVLS fan as their choice over other major competitors simply because of our expertise and good consultation services.

53.

PortFolio

Page 28: HVLS...Standards Max. Ambient Temperature for Operation Integrated Blower Fan cURus, GOST-R, CCC & UkrSepro 50 Celcius Standards cURus, GOST-R, CCC & UkrSepro Sound Level 50 ~ 55 dB

55.

At AireGard, we set ourselves apart from the

competition by providing professional installation,

excellent customer service and prompt after-sales

services. Our promise is only possible simply

because of Gard Squad, our in-house technical

team who are well groomed for the job to deliver

superb customer satisfaction.

Specially factory-trained and certified, Gard Squad

team takes the guess work out of any problems or

service call and in reliably quick time.

SITE EVALUATION

Our trained engineers will visit your site to evaluate the

situation

PROPOSAL

We will present the proposal to you and explain thoroughly

on what should you install and why.

DESIGN

Valuable info collected from site visit will be important for

our team to design an action plan for your site.

Gard squad