183
Huawei OceanStor 5300F V5 Converged Storage Interoperability Matrix Date: 10/09/2019 Copyright ©Huawei Technologies Co., Ltd. 1

Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

  • Upload
    others

  • View
    46

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

Huawei OceanStor 5300F V5 Converged Storage

Interoperability Matrix

Date: 10/09/2019

Copyright ©Huawei Technologies Co., Ltd.

1

Page 2: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service.

For any assistance, please contact our local representative office, agency, or customer service center.

Huawei Technologies Co., Ltd.

Address: Huawei Industrial Base

Bantian, Longgang

Shenzhen 518129

People's Republic of China

Website: http://www.huawei.com

Email: [email protected]

Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.

No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of

Huawei Technologies Co., Ltd.

Trademark Notice

and other Huawei trademarks are trademarks or registered trademarks of Huawei Technologies Co., Ltd.

Other trademarks, products, services and company names mentioned are the property of their respective owners.

NO WARRANTY

THE CONTENTS OF THIS DOCUMENT ARE FOR REFERENCE ONLY AND DO NOT CONSTITUTE ANY FORM OF

COMMITMENT. EXCEPT AS REQUIRED BY APPLICABLE LAWS,NO WARRANTIES OF ANY KIND,EITHER EXPRESS

OR IMPLIED,INCLUDING BUT NOT LIMITED TO,ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A

PARTICULAR PURPOSE,ARE MADE IN RELATION TO THE CONTENTS OF THIS DOCUMENT.THE INFORMATION IN

THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE.

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL HUAWEI TECHNOLOGIES

CO., LTD BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES OF ANY KIND,

OR FOR LOSS OF PROFIT, DATA, GOODWILL OR ANTICIPATED SAVINGS ARISING OUT OF OR IN CONNECTION

WITH THE USE OF THIS DOCUMENT.

UNLESS OTHERWISE SPECIFIED, WARRANTY, SERVICE, AND SUPPORT FOR NON-HUAWEI PRODUCTS ARE

PROVIDED DIRECTLY TO YOU BY THE PRODUCT MANUFACTURER, SUPPLIER OR PUBLISHER OF THE

PRODUCT. HUAWEI MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE NON-HUAWEI

2

Page 3: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

PRODUCTES. FOR SUPPORT ISSUES REGARDING NON-HUAWEI PRODUCTS, PLEASE CONTACT THE

MANUFACTURER OF THE PRODUCT DIRECTLY. HUAWEI DOES NOT PROVIDE SERVICE OR SUPPORT FOR THE

NON-HUAWEI PRODUCTS LISTED, BUT DOES NOT PROHIBIT THEM FORM BEING USED TOGETHER WITH

HUAWEI’S STORAGE PRODUCTS.

3

Page 4: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

Selections

OperatingSystem

MicrosoftWindows Server2012

OperatingSystem

MicrosoftWindows Server2012 R2

OperatingSystem

MicrosoftWindows Server2012 R2Standard x64Edition

OperatingSystem

MicrosoftWindows Server2012 R2 withHyper-V

OperatingSystem

MicrosoftWindows Server2012 withHyper-V

OperatingSystem

MicrosoftWindows Server2016

OperatingSystem

MicrosoftWindows Server2016 withHyper-V

OperatingSystem

MicrosoftWindows Server2019

OperatingSystem

MicrosoftWindows Server2019 withHyper-V

4

Page 5: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

Basic Connectivity

The table lists operating systems, multipathing software, and host bus

adapters supported by Huawei storage.You can use the following method to

identify SmartIO interface modules:

1. 4 Ports SmartIO 16Gbps/8Gbps indicates the first-generation SmartIO

interface modules, and 4 Ports SmartIO 32Gbps/16Gbps/8Gbps indicates the

second-generation SmartIO interface modules.

2. For details about the differences between the front panels of 4 Ports

SmartIO 16Gbps/8Gbps and 4 Ports SmartIO 32Gbps/16Gbps/8Gbps interface

modules, see the following link:http://support-

open.huawei.com/en/files/document/host-doc/SmartIO.pdf

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 iSCSI 4 Ports SmartIO25Gbps ETH

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

BroadcomNetXTremeP225p

MPIO OceanStor5300F V5

V500R007 1

2 iSCSI 4 Ports SmartIO25Gbps ETH

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

BroadcomNetXTremeP225p

MPIO OceanStor5300F V5

V500R007 1

3 iSCSI 4 Ports SmartIO25Gbps ETH

Huawei RHRack Servers

MicrosoftWindowsServer 2012

BroadcomNetXTremeP225p

MPIO OceanStor5300F V5

V500R007 1

4 iSCSI 4 Ports SmartIO25Gbps ETH

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

BroadcomNetXTremeP225p

MPIO OceanStor5300F V5

V500R007 1

5 iSCSI 4 Ports SmartIO25Gbps ETH

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

BroadcomNetXTremeP225p

MPIO OceanStor5300F V5

V500R007 1

6 iSCSI 4 Ports SmartIO25Gbps ETH

Oracle x86Servers

MicrosoftWindowsServer 2012

BroadcomNetXTremeP225p

MPIO OceanStor5300F V5

V500R007 1

7 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

8 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3,4

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

10 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

11 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

12 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

13 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

14 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

15 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

16 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3,4

5

Page 6: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

18 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

19 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

20 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

Brocade 825 UltraPath OceanStor5300F V5

V500R007 2,3

1 The storage system version must be V500R007C30 or later.

2 Set the port type of the storage system to "Point-to-Point" in direct-connection networking scenarios.

3 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

4 Set the FLOGI latency to 500 µs for the port that connects the storage device and the host HBA in direct-connection networkingscenarios. The CLI command is: change port fc FC Port ID flogin_delay_times=500.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,3

3 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,3

4 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,3

5 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,3

6 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,3

7 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,3

8 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,3

9 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,3

11 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,3

12 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,3

13 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELL 331-0237

UltraPath OceanStor5300F V5

V500R007 1,3

14 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELL 331-0238

UltraPath OceanStor5300F V5

V500R007 1,3

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLDH226

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 4

16 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLF641C

MPIO OceanStor5300F V5

V500R007 5

17 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLF641C

UltraPath OceanStor5300F V5

V500R007 3

6

Page 7: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELL FF340 9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 4

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLFH590

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 4

20 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLH144C

MPIO OceanStor5300F V5

V500R007 5

1 Set the port type of the storage system to "Point-to-Point" in direct-connection networking scenarios.

2 Set the FLOGI latency to 500 µs for the port that connects the storage device and the host HBA in direct-connection networkingscenarios. The CLI command is: change port fc FC Port ID flogin_delay_times=500.

3 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

4 The storage system version must be V500R007C30 or later.

5 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLH144C

UltraPath OceanStor5300F V5

V500R007 1

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLLP1150-E

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

3 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLLP1150-E

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLLP1150-E

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLLPe1150-E

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

6 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLLPe1150-E

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

7 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLLPe1150-E

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

8 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLLPe12000-E

UltraPath OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLLPe12000-E

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 1,4,5

10 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLLPe12002-E

UltraPath OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELLLPe12002-E

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 1,4,5

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

DELL PF323 9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 5

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

14 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

15 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

17 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

7

Page 8: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

18 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

20 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 Set the port topology of the HBA to arbitrated loop in direct-connection networking scenarios.

3 The HBA driver version is 2.72.012.001, and the firmware version is 1.00A11.

4 Microsoft hotfix Q2821052 is required. For details, refer to http://support.microsoft.com/kb/2821052/EN-US. To obtain thishotfix, visit http://support.microsoft.com/hotfix/KBHotfix.aspx?kbnum=2821052&kbln=en-us.

5 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

3 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

6 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

7 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

9 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

10 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLP1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

12 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

13 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

15 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

16 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

8

Page 9: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

18 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

19 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

2 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

5 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

7 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

8 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe1150

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

9 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2,3

20 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2,3

9

Page 10: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 Set the port topology of the HBA to arbitrated loop in direct-connection networking scenarios.

2 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

3 The HBA driver version is 2.72.012.001, and the firmware version is 1.00A11.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 2,4,5

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 2,4,5

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 2,4,5

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 2,4,5

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe12000

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 2,4,5

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe12000

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 2,4,5

8 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2,3

20 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2,3

1 Set the port topology of the HBA to arbitrated loop in direct-connection networking scenarios.

2 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

3 The HBA driver version is 2.72.012.001, and the firmware version is 1.00A11.

10

Page 11: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

4 Microsoft hotfix Q2821052 is required. For details, refer to http://support.microsoft.com/kb/2821052/EN-US. To obtain thishotfix, visit http://support.microsoft.com/hotfix/KBHotfix.aspx?kbnum=2821052&kbln=en-us.

5 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe12002

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe12002

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

8 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

9 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

11 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

12 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

14 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

15 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

17 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

18 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

20 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 Microsoft hotfix Q2821052 is required. For details, refer to http://support.microsoft.com/kb/2821052/EN-US. To obtain thishotfix, visit http://support.microsoft.com/hotfix/KBHotfix.aspx?kbnum=2821052&kbln=en-us.

3 The storage system version must be V500R007C30 or later.

11

Page 12: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

3 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

6 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

7 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

8 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 4 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

1 The HBA only supports the switch-connection networking scenarios.

2 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

3 The HBA driver version is 2.74.014.001.

12

Page 13: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 1,2,3

20 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 1,2,3

1 The HBA only supports the switch-connection networking scenarios.

2 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

3 The HBA driver version is 2.74.014.001.

13

Page 14: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

1 The HBA only supports the switch-connection networking scenarios.

2 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

3 The HBA driver version is 2.74.014.001.

14

Page 15: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2,3

20 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2,3

1 The HBA only supports the switch-connection networking scenarios.

2 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

3 The HBA driver version is 2.74.014.001.

15

Page 16: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

11 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

12 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

14 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

15 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

17 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

18 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

20 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

1 The HBA only supports the switch-connection networking scenarios.

2 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

3 The HBA driver version is 2.74.014.001.

16

Page 17: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

3 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

4 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

6 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

7 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

9 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

10 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe31000

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

12 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

13 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

15 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

16 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

18 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

19 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

17

Page 18: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

2 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

4 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

5 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

7 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

8 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

10 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

11 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe31002

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

13 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

14 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

16 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

17 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

19 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

20 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

2 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

3 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

18

Page 19: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

5 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

6 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

8 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

9 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

11 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

12 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe31004

11.1.145.16 11.2.156.27 MPIO OceanStor5300F V5

V500R007

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32000

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32000

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32000

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32000

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe32000

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe32000

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

20 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

1 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

3 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

19

Page 20: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

6 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

7 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

9 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

10 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

12 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

13 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

15 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

16 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

18 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

19 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

1 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe32002

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe32002

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32004

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32004

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

20

Page 21: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32004

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

EmulexLPe32004

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

EmulexLPe32004

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

EmulexLPe32004

12.0.193.13 UltraPath OceanStor5300F V5

V500R007 1

12 iSCSI iSCSI 10GE DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

GenericVendor NIC10GbE

MPIO OceanStor5300F V5

V500R007

13 iSCSI iSCSI 10GE HP ProLiantRack Servers

MicrosoftWindowsServer 2012

GenericVendor NIC10GbE

MPIO OceanStor5300F V5

V500R007

14 iSCSI iSCSI 10GE Huawei RHRack Servers

MicrosoftWindowsServer 2012

GenericVendor NIC10GbE

MPIO OceanStor5300F V5

V500R007

15 iSCSI iSCSI 10GE IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

GenericVendor NIC10GbE

MPIO OceanStor5300F V5

V500R007

16 iSCSI iSCSI 10GE Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

GenericVendor NIC10GbE

MPIO OceanStor5300F V5

V500R007

17 iSCSI iSCSI GE DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

GenericVendor NICGbE

MPIO OceanStor5300F V5

V500R007 2,3

18 iSCSI iSCSI GE FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

GenericVendor NICGbE

MPIO OceanStor5300F V5

V500R007 2,3

19 iSCSI iSCSI GE HP ProLiantRack Servers

MicrosoftWindowsServer 2012

GenericVendor NICGbE

MPIO OceanStor5300F V5

V500R007 2,3

20 iSCSI iSCSI GE Huawei RHRack Servers

MicrosoftWindowsServer 2012

GenericVendor NICGbE

MPIO OceanStor5300F V5

V500R007 2,3

1 The storage system version must be V500R007C30 or later.

2 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

3 The HBA driver version is 2.8.32.0.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 iSCSI iSCSI GE IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

GenericVendor NICGbE

MPIO OceanStor5300F V5

V500R007 1,2

2 iSCSI iSCSI GE Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

GenericVendor NICGbE

MPIO OceanStor5300F V5

V500R007 1,2

3 iSCSI iSCSI GE Oracle x86Servers

MicrosoftWindowsServer 2012

GenericVendor NICGbE

MPIO OceanStor5300F V5

V500R007 1,2

4 iSCSI iSCSI GE FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

GenericVendor NICGbE

UltraPath OceanStor5300F V5

V500R007 1

5 iSCSI iSCSI GE Oracle x86Servers

MicrosoftWindowsServer 2012

GenericVendor NICGbE

UltraPath OceanStor5300F V5

V500R007 1

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HPAB429A/FC1143

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 3

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HPAE311A/FC1142SR

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 3

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HPAE312A/FC1242SR

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 3

21

Page 22: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HPAE369A/FC1243

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 3

10 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP AJ762A UltraPath OceanStor5300F V5

V500R007 1,4,5

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP AJ762A 11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 1,3,6

12 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP AJ763A UltraPath OceanStor5300F V5

V500R007 1,4,5

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP AJ763A 11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 1,3,6

14 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HPAJ764A/82Q

MPIO OceanStor5300F V5

V500R007 7

15 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HPAJ764A/82Q

UltraPath OceanStor5300F V5

V500R007 1

16 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HPAK344A/81Q

MPIO OceanStor5300F V5

V500R007 7

17 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HPAK344A/81Q

UltraPath OceanStor5300F V5

V500R007 1

18 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP AP769A UltraPath OceanStor5300F V5

V500R007 1,8

19 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP AP770A UltraPath OceanStor5300F V5

V500R007 1,8

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HPFC2142SR

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 The HBA driver version is 2.8.32.0.

3 The storage system version must be V500R007C30 or later.

4 Set the port topology of the HBA to arbitrated loop in direct-connection networking scenarios.

5 The HBA driver version is 2.72.012.001, and the firmware version is 1.00A11.

6 Microsoft hotfix Q2821052 is required. For details, refer to http://support.microsoft.com/kb/2821052/EN-US. To obtain thishotfix, visit http://support.microsoft.com/hotfix/KBHotfix.aspx?kbnum=2821052&kbln=en-us.

7 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

8 Set the port type of the storage system to "Point-to-Point" in direct-connection networking scenarios.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HPFC2142SR

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

2 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HPFC2142SR

2.72.205.4 2.50A6 UltraPath OceanStor5300F V5

V500R007

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantBlade Series

MicrosoftWindowsServer 2012

HPFlexFabric554FLB(647586-B21)

2.72.205.004 UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 16Gbps FC HP ProLiantBlade Series

MicrosoftWindowsServer 2012

HPFlexFabric554FLB(647586-B21)

2.72.205.004 UltraPath OceanStor5300F V5

V500R007

5 FC 8 Ports 8Gbps FC HP ProLiantBlade Series

MicrosoftWindowsServer 2012

HPFlexFabric554FLB(647586-B21)

2.72.205.004 UltraPath OceanStor5300F V5

V500R007

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantBlade Series

MicrosoftWindowsServer 2012

HPLPe1605(718203-B21)

10.2.370.8 UltraPath OceanStor5300F V5

V500R007

22

Page 23: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

7 FC 8 Ports 16Gbps FC HP ProLiantBlade Series

MicrosoftWindowsServer 2012

HPLPe1605(718203-B21)

10.2.370.8 UltraPath OceanStor5300F V5

V500R007

8 FC 8 Ports 8Gbps FC HP ProLiantBlade Series

MicrosoftWindowsServer 2012

HPLPe1605(718203-B21)

10.2.370.8 UltraPath OceanStor5300F V5

V500R007

9 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP QR558A MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP QR558A MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP QR558A MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP QR558A MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP QR558A UltraPath OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP QR559A MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP QR559A MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP QR559A MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP QR559A MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

HP QR559A UltraPath OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports 8Gbps FC HuaweiE6000 BladeSeries

MicrosoftWindowsServer 2012

HuaweiMU220

UltraPath OceanStor5300F V5

V500R007 3

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

HuaweiE6000 BladeSeries

MicrosoftWindowsServer 2012

HuaweiMU220

UltraPath OceanStor5300F V5

V500R007 3

1 The HBA only supports the switch-connection networking scenarios.

2 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

3 The HBA driver version is 2.74.014.001.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC HuaweiE6000 BladeSeries

MicrosoftWindowsServer 2012

HuaweiMU220

UltraPath OceanStor5300F V5

V500R007 1

2 FC 8 Ports 8Gbps FC HuaweiE6000 BladeSeries

MicrosoftWindowsServer 2012

HuaweiMU220

UltraPath OceanStor5300F V5

V500R007 1

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM39M5894

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 2

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM39M5894

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 2

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM39M5895

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 2

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM39M5895

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 2

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM39R6525

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 2

23

Page 24: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM39R6525

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 2

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM39R6527

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 2

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM39R6527

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 2

11 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM42D0485

UltraPath OceanStor5300F V5

V500R007 3,4,5

12 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM42D0485

UltraPath OceanStor5300F V5

V500R007 3,4,5

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM42D0485

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 2,4,6

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM42D0485

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 2,4,6

15 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM42D0494

UltraPath OceanStor5300F V5

V500R007 3,4,5

16 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM42D0494

UltraPath OceanStor5300F V5

V500R007 3,4,5

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM42D0494

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 2,4,6

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM42D0494

11.1.145.16 2.01A11 MPIO OceanStor5300F V5

V500R007 2,4,6

19 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM42D0501

MPIO OceanStor5300F V5

V500R007 7

20 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM42D0501

MPIO OceanStor5300F V5

V500R007 7

1 The HBA driver version is 2.74.014.001.

2 The storage system version must be V500R007C30 or later.

3 Set the port topology of the HBA to arbitrated loop in direct-connection networking scenarios.

4 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

5 The HBA driver version is 2.72.012.001, and the firmware version is 1.00A11.

6 Microsoft hotfix Q2821052 is required. For details, refer to http://support.microsoft.com/kb/2821052/EN-US. To obtain thishotfix, visit http://support.microsoft.com/hotfix/KBHotfix.aspx?kbnum=2821052&kbln=en-us.

7 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1

2 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1

3 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM42D0510

MPIO OceanStor5300F V5

V500R007 2

4 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM42D0510

MPIO OceanStor5300F V5

V500R007 2

5 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1

6 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1

24

Page 25: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

7 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM46M6049

UltraPath OceanStor5300F V5

V500R007 1,3

8 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM46M6049

UltraPath OceanStor5300F V5

V500R007 1,3

9 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM46M6050

UltraPath OceanStor5300F V5

V500R007 1,3

10 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM46M6050

UltraPath OceanStor5300F V5

V500R007 1,3

11 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM81Y1655

MPIO OceanStor5300F V5

V500R007 1,4,5

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM81Y1655

MPIO OceanStor5300F V5

V500R007 1,4,5

13 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM81Y1655

MPIO OceanStor5300F V5

V500R007 1,4,5

14 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM81Y1655

MPIO OceanStor5300F V5

V500R007 1,4,5

15 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM81Y1655

MPIO OceanStor5300F V5

V500R007 1,4,5

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM81Y1655

MPIO OceanStor5300F V5

V500R007 1,4,5

17 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM81Y1655

MPIO OceanStor5300F V5

V500R007 1,4,5

18 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM81Y1655

MPIO OceanStor5300F V5

V500R007 1,4,5

19 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM81Y1655

UltraPath OceanStor5300F V5

V500R007 1,4,5

20 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM81Y1655

UltraPath OceanStor5300F V5

V500R007 1,4,5

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

3 Set the port type of the storage system to "Point-to-Point" in direct-connection networking scenarios.

4 The HBA only supports the switch-connection networking scenarios.

5 The HBA driver version is 2.74.014.001.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM81Y1662

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM81Y1662

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM81Y1662

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM81Y1662

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM81Y1662

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM81Y1662

MPIO OceanStor5300F V5

V500R007 1,2,3

25

Page 26: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

7 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM81Y1662

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM81Y1662

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

IBM81Y1662

UltraPath OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

IBM81Y1662

UltraPath OceanStor5300F V5

V500R007 1,2,3

11 iSCSI iSCSI 10GE DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

Intel X520-SR2

MPIO OceanStor5300F V5

V500R007 2,4

12 iSCSI iSCSI 10GE FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

Intel X520-SR2

MPIO OceanStor5300F V5

V500R007 2,4

13 iSCSI iSCSI 10GE HP ProLiantRack Servers

MicrosoftWindowsServer 2012

Intel X520-SR2

MPIO OceanStor5300F V5

V500R007 2,4

14 iSCSI iSCSI 10GE Huawei RHRack Servers

MicrosoftWindowsServer 2012

Intel X520-SR2

MPIO OceanStor5300F V5

V500R007 2,4

15 iSCSI iSCSI 10GE IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

Intel X520-SR2

MPIO OceanStor5300F V5

V500R007 2,4

16 iSCSI iSCSI 10GE Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

Intel X520-SR2

MPIO OceanStor5300F V5

V500R007 2,4

17 iSCSI iSCSI 10GE Oracle x86Servers

MicrosoftWindowsServer 2012

Intel X520-SR2

MPIO OceanStor5300F V5

V500R007 2,4

18 iSCSI iSCSI 10GE FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007 2,4

19 iSCSI iSCSI 10GE Oracle x86Servers

MicrosoftWindowsServer 2012

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007 2,4

20 iSCSI iSCSI 10GE FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

Intel X540-T2 NIC10GbE

UltraPath OceanStor5300F V5

V500R007 2,4

1 The HBA only supports the switch-connection networking scenarios.

2 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

3 The HBA driver version is 2.74.014.001.

4 The HBA driver version is 2.8.32.0.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 iSCSI iSCSI 10GE Oracle x86Servers

MicrosoftWindowsServer 2012

Intel X540-T2 NIC10GbE

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

3 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3,4

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

5 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

6 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

7 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

26

Page 27: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

8 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

9 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

10 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

11 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3,4

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

13 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

14 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

15 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,3

16 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,3,4

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,3

18 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,3

19 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,3

20 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,3

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 The HBA driver version is 2.8.32.0.

3 Set the port type of the storage system to "Point-to-Point" in direct-connection networking scenarios.

4 Set the FLOGI latency to 500 µs for the port that connects the storage device and the host HBA in direct-connection networkingscenarios. The CLI command is: change port fc FC Port ID flogin_delay_times=500.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

27

Page 28: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

8 iSCSI 4 Ports SmartIO25Gbps ETH

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicFastLinQQL41262HLCU

MPIO OceanStor5300F V5

V500R007 4

9 iSCSI 4 Ports SmartIO25Gbps ETH

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicFastLinQQL41262HLCU

MPIO OceanStor5300F V5

V500R007 4

10 iSCSI 4 Ports SmartIO25Gbps ETH

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicFastLinQQL41262HLCU

MPIO OceanStor5300F V5

V500R007 4

11 iSCSI 4 Ports SmartIO25Gbps ETH

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicFastLinQQL41262HLCU

MPIO OceanStor5300F V5

V500R007 4

12 iSCSI 4 Ports SmartIO25Gbps ETH

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicFastLinQQL41262HLCU

MPIO OceanStor5300F V5

V500R007 4

13 iSCSI 4 Ports SmartIO25Gbps ETH

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicFastLinQQL41262HLCU

MPIO OceanStor5300F V5

V500R007 4

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLA2460

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 4

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLA2460

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 4

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLA2460

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 4

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLA2460

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 4

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLA2460

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 4

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLA2460

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 4

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLA2462

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 4

1 Set the port type of the storage system to "Point-to-Point" in direct-connection networking scenarios.

2 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

3 Set the FLOGI latency to 500 µs for the port that connects the storage device and the host HBA in direct-connection networkingscenarios. The CLI command is: change port fc FC Port ID flogin_delay_times=500.

4 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLA2462

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLA2462

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLA2462

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLA2462

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLA2462

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2460

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

28

Page 29: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2460

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2460

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2460

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2460

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2460

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2462

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2462

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2462

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2462

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2462

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2462

9.1.9.205 5.04.01 MPIO OceanStor5300F V5

V500R007 1

18 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2

20 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2

1 The storage system version must be V500R007C30 or later.

2 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

2 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

3 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

4 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

5 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

7 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

8 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

29

Page 30: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

9 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

11 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

12 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

13 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

15 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

16 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

17 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

19 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

20 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

1 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

2 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

3 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

4 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

5 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

7 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

8 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

9 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

30

Page 31: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

11 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

12 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

13 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

15 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

16 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

17 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2

19 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2

20 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

2 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

3 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

4 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

6 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

7 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1

8 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

10 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

31

Page 32: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

11 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

12 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

14 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

15 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

16 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

18 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

19 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

20 FC 4 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

1 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

2 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

2 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

3 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

4 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

6 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

7 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

8 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

10 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

11 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

32

Page 33: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

12 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

14 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

15 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

16 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 Microsoft hotfix Q2821052 is required. For details, refer to http://support.microsoft.com/kb/2821052/EN-US. To obtain thishotfix, visit http://support.microsoft.com/hotfix/KBHotfix.aspx?kbnum=2821052&kbln=en-us.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

8 FC 4 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

33

Page 34: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 Microsoft hotfix Q2821052 is required. For details, refer to http://support.microsoft.com/kb/2821052/EN-US. To obtain thishotfix, visit http://support.microsoft.com/hotfix/KBHotfix.aspx?kbnum=2821052&kbln=en-us.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1

5 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1

7 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1

8 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1

9 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1

10 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1

11 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1

12 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1

13 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1

34

Page 35: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1

15 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1

16 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

18 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

19 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 Microsoft hotfix Q2821052 is required. For details, refer to http://support.microsoft.com/kb/2821052/EN-US. To obtain thishotfix, visit http://support.microsoft.com/hotfix/KBHotfix.aspx?kbnum=2821052&kbln=en-us.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

2 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

5 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

7 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

8 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

10 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

11 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

13 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

14 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

35

Page 36: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

16 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

17 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.9.20 7.03.00 MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.9.20 7.03.00 MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.9.20 7.03.00 MPIO OceanStor5300F V5

V500R007 1,2,3

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 Microsoft hotfix Q2821052 is required. For details, refer to http://support.microsoft.com/kb/2821052/EN-US. To obtain thishotfix, visit http://support.microsoft.com/hotfix/KBHotfix.aspx?kbnum=2821052&kbln=en-us.

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.9.20 7.03.00 MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.9.20 7.03.00 MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.9.20 7.03.00 MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.9.20 7.03.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.9.20 7.03.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.9.20 7.03.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.9.20 7.03.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.9.20 7.03.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2670

9.2.9.20 7.03.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

14 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

36

Page 37: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

16 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 Microsoft hotfix Q2821052 is required. For details, refer to http://support.microsoft.com/kb/2821052/EN-US. To obtain thishotfix, visit http://support.microsoft.com/hotfix/KBHotfix.aspx?kbnum=2821052&kbln=en-us.

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

14 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

37

Page 38: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

17 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1

19 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 Microsoft hotfix Q2821052 is required. For details, refer to http://support.microsoft.com/kb/2821052/EN-US. To obtain thishotfix, visit http://support.microsoft.com/hotfix/KBHotfix.aspx?kbnum=2821052&kbln=en-us.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1

2 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1

3 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1

4 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1

5 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1

6 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1

7 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1

9 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1

10 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

12 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

13 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

15 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

16 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

38

Page 39: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

18 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

19 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

2 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

5 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

7 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

8 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

10 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

11 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.1.20 6.02.00 UltraPath OceanStor5300F V5

V500R007

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.9.20 7.03.00 MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.9.20 7.03.00 MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.9.20 7.03.00 MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.9.20 7.03.00 MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.9.20 7.03.00 MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.9.20 7.03.00 MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.9.20 7.03.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.9.20 7.03.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

39

Page 40: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.9.20 7.03.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 Microsoft hotfix Q2821052 is required. For details, refer to http://support.microsoft.com/kb/2821052/EN-US. To obtain thishotfix, visit http://support.microsoft.com/hotfix/KBHotfix.aspx?kbnum=2821052&kbln=en-us.

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.9.20 7.03.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.9.20 7.03.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2672

9.2.9.20 7.03.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2692

9.2.9.20 8.03.04 MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2692

9.2.9.20 8.03.04 MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2692

9.2.9.20 8.03.04 MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2692

9.2.9.20 8.03.04 MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2692

9.2.9.20 8.03.04 MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2692

9.2.9.20 8.03.04 MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

11 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

12 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

14 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

15 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

17 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

18 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

20 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

40

Page 41: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 Microsoft hotfix Q2821052 is required. For details, refer to http://support.microsoft.com/kb/2821052/EN-US. To obtain thishotfix, visit http://support.microsoft.com/hotfix/KBHotfix.aspx?kbnum=2821052&kbln=en-us.

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

3 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

6 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

7 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

9 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

10 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

12 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

13 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

15 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

16 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

18 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

19 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

41

Page 42: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

2 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

5 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

7 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

8 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

10 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

11 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

9.2.9.20 UltraPath OceanStor5300F V5

V500R007 1

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

9.2.9.20 UltraPath OceanStor5300F V5

V500R007 1

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

9.2.9.20 UltraPath OceanStor5300F V5

V500R007 1

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

9.2.9.20 UltraPath OceanStor5300F V5

V500R007 1

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2742

9.2.9.20 UltraPath OceanStor5300F V5

V500R007 1

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2742

9.2.9.20 UltraPath OceanStor5300F V5

V500R007 1

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

19 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

20 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

1 The storage system version must be V500R007C30 or later.

42

Page 43: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

2 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

3 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

5 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

6 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

8 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

9 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

11 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

12 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

14 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

15 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

17 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

18 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

19 FC 4 Ports 8Gbps FC HP ProLiantBlade Series

MicrosoftWindowsServer 2012

QLogicQMH2562

UltraPath OceanStor5300F V5

V500R007

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantBlade Series

MicrosoftWindowsServer 2012

QLogicQMH2562

UltraPath OceanStor5300F V5

V500R007

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC HP ProLiantBlade Series

MicrosoftWindowsServer 2012

QLogicQMH2562

UltraPath OceanStor5300F V5

V500R007

2 FC 8 Ports 8Gbps FC HP ProLiantBlade Series

MicrosoftWindowsServer 2012

QLogicQMH2562

UltraPath OceanStor5300F V5

V500R007

43

Page 44: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantBlade Series

MicrosoftWindowsServer 2012

QLogicQMH2672

9.2.1.20 UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 16Gbps FC HP ProLiantBlade Series

MicrosoftWindowsServer 2012

QLogicQMH2672

9.2.1.20 UltraPath OceanStor5300F V5

V500R007

5 FC 8 Ports 8Gbps FC HP ProLiantBlade Series

MicrosoftWindowsServer 2012

QLogicQMH2672

9.2.1.20 UltraPath OceanStor5300F V5

V500R007

6 iSCSI iSCSI 10GE FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

Brocade1010

MPIO OceanStor5300F V5

V500R007 1

7 iSCSI iSCSI 10GE Oracle x86Servers

MicrosoftWindowsServer 2012R2

Brocade1010

MPIO OceanStor5300F V5

V500R007 1

8 iSCSI iSCSI 10GE FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

Brocade1020

MPIO OceanStor5300F V5

V500R007 1

9 iSCSI iSCSI 10GE Oracle x86Servers

MicrosoftWindowsServer 2012R2

Brocade1020

MPIO OceanStor5300F V5

V500R007 1

10 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

11 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3,4

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

13 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

14 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

15 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

16 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

17 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

18 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

19 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3,4

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

Brocade 815 UltraPath OceanStor5300F V5

V500R007 2,3

1 Install patch KB2822241 if KB2779768 has already been installed in the operating system. Otherwise, the multipath software willnot take effect. To obtain this hotfix, visit http://www.microsoft.com/en-us/download/details.aspx?id=38240.

2 Set the port type of the storage system to "Point-to-Point" in direct-connection networking scenarios.

3 Select Windows Server 2012 as the operating system of the host.

4 Set the FLOGI latency to 500 µs for the port that connects the storage device and the host HBA in direct-connection networkingscenarios. The CLI command is: change port fc FC Port ID flogin_delay_times=500.

44

Page 45: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

Brocade 815 UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

Brocade 815 UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

Brocade 825 UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELL 331-0237

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELL 331-0238

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLF641C

MPIO OceanStor5300F V5

V500R007 2,4

45

Page 46: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLF641C

MPIO OceanStor5300F V5

V500R007 2,4

20 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLF641C

MPIO OceanStor5300F V5

V500R007 2,4

1 Set the port type of the storage system to "Point-to-Point" in direct-connection networking scenarios.

2 Select Windows Server 2012 as the operating system of the host.

3 Set the FLOGI latency to 500 µs for the port that connects the storage device and the host HBA in direct-connection networkingscenarios. The CLI command is: change port fc FC Port ID flogin_delay_times=500.

4 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLF641C

MPIO OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLF641C

UltraPath OceanStor5300F V5

V500R007 2

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLF641C

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 2,3

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLF641C

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3

5 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLH144C

MPIO OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLH144C

MPIO OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLH144C

MPIO OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLH144C

MPIO OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLH144C

UltraPath OceanStor5300F V5

V500R007 2

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLH144C

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 2,3

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLH144C

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3

12 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLLPe12000-E

MPIO OceanStor5300F V5

V500R007 1,2,4

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLLPe12000-E

MPIO OceanStor5300F V5

V500R007 1,2,4

14 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLLPe12000-E

MPIO OceanStor5300F V5

V500R007 1,2,4

46

Page 47: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

15 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLLPe12000-E

MPIO OceanStor5300F V5

V500R007 1,2,4

16 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLLPe12000-E

UltraPath OceanStor5300F V5

V500R007 2,4

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLLPe12000-E

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 2,3

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLLPe12000-E

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 2,3

19 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLLPe12002-E

MPIO OceanStor5300F V5

V500R007 1,2,4

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLLPe12002-E

MPIO OceanStor5300F V5

V500R007 1,2,4

1 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

2 Select Windows Server 2012 as the operating system of the host.

3 The storage system version must be V500R007C30 or later.

4 Set the port topology of the HBA to arbitrated loop in direct-connection networking scenarios.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLLPe12002-E

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLLPe12002-E

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLLPe12002-E

UltraPath OceanStor5300F V5

V500R007 1,3

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLLPe12002-E

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 3,4

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

DELLLPe12002-E

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 3,4

6 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

47

Page 48: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

1 Set the port topology of the HBA to arbitrated loop in direct-connection networking scenarios.

2 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

3 Select Windows Server 2012 as the operating system of the host.

4 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

48

Page 49: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,3

15 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,3

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,3

17 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,3

18 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,3

19 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,3

20 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,3

1 Set the port topology of the HBA to arbitrated loop in direct-connection networking scenarios.

2 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

3 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

49

Page 50: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

3 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 2,3

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 2,3

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 2,3

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 2,3

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe12000

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 2,3

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 2,3

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 2,3

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 2,3

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 2,3

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 2,3

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe12000

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 2,3

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12000

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 2,3

19 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,4

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,4

1 Set the port topology of the HBA to arbitrated loop in direct-connection networking scenarios.

2 Select Windows Server 2012 as the operating system of the host.

3 The storage system version must be V500R007C30 or later.

4 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

50

Page 51: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

51

Page 52: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

19 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

1 Set the port topology of the HBA to arbitrated loop in direct-connection networking scenarios.

2 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

3 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,3

8 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,3

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,3

10 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,3

11 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,3

12 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,3

13 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,3

14 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,3

52

Page 53: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

15 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,3

16 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,3

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,3

18 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,3

19 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,3

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 3,4

1 Set the port topology of the HBA to arbitrated loop in direct-connection networking scenarios.

2 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

3 Select Windows Server 2012 as the operating system of the host.

4 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe12002

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe12002

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 1,2

53

Page 54: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe12002

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeBlade Series

MicrosoftWindowsServer 2012R2

EmulexLPe1205-M

2.74.214.004 2.00A5 UltraPath OceanStor5300F V5

V500R007

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

14 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

15 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

17 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

18 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

20 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

3 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

6 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

7 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

54

Page 55: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

9 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

10 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

12 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

13 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007

14 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2

1 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

2 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 1,2

55

Page 56: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

5 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 2,3

6 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 2,3

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 2,3

8 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 2,3

9 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 2,3

10 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 2,3

11 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 2,3

12 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 2,3

13 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 2,3

14 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 2,3

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 2,3

16 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 2,3

17 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

UltraPath OceanStor5300F V5

V500R007 2,3

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 2,4

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 2,4

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 2,4

1 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

2 Select Windows Server 2012 as the operating system of the host.

3 The HBA only supports the switch-connection networking scenarios.

4 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

56

Page 57: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe16000

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe16000

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16000

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16000B

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16000B

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16000B

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16000B

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPE16000B

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16000B

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16000B

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16000B

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16000B

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16000B

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPE16000B

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

1 Select Windows Server 2012 as the operating system of the host.

57

Page 58: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

2 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16000B

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,3

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,3

4 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,3

5 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,3

6 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,3

7 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,3

8 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,3

9 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,3

11 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,3

12 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1,3

13 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,4

14 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,4

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,4

16 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,4

17 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,4

58

Page 59: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

18 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,4

19 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,4

20 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,4

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

3 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

4 The HBA only supports the switch-connection networking scenarios.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 2,3

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 2,3

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 2,3

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 2,3

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe16002

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 2,3

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 2,3

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 2,3

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 2,3

59

Page 60: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 2,3

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 2,3

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe16002

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 2,3

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 2,3

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

10.7.110.20 11.1.127.0 UltraPath OceanStor5300F V5

V500R007

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

10.7.110.20 11.1.127.0 UltraPath OceanStor5300F V5

V500R007

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

10.7.110.20 11.1.127.0 UltraPath OceanStor5300F V5

V500R007

1 The HBA only supports the switch-connection networking scenarios.

2 Select Windows Server 2012 as the operating system of the host.

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

10.7.110.20 11.1.127.0 UltraPath OceanStor5300F V5

V500R007

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

10.7.110.20 11.1.127.0 UltraPath OceanStor5300F V5

V500R007

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

10.7.110.20 11.1.127.0 UltraPath OceanStor5300F V5

V500R007

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

10.7.110.20 11.1.127.0 UltraPath OceanStor5300F V5

V500R007

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

60

Page 61: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe16002B

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16004

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16004

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16004

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16004

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPE16004

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16004

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16004

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16004

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16004

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16004

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPE16004

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

61

Page 62: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPE16004

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

10 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

11 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

13 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

14 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

16 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

17 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

19 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

20 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

2 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

3 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

62

Page 63: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

5 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

6 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

8 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

9 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31000

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

11 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

12 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

14 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

15 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

17 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

18 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

20 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

63

Page 64: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

3 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

6 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

7 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

9 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

10 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31002

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

12 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

13 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

15 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

16 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

18 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

19 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

64

Page 65: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

2 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

5 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

7 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

8 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

10 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

11 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe31004

11.1.145.16 11.2.156.27 UltraPath OceanStor5300F V5

V500R007

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32000

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32000

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32000

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32000

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe32000

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32000

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

19 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

20 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

1 Select Windows Server 2012 as the operating system of the host.

65

Page 66: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

2 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

2 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

3 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

5 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

6 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

8 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

9 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

11 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

12 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

14 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

15 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

17 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

66

Page 67: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

18 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

MPIO OceanStor5300F V5

V500R007

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe32002

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32002

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32004

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32004

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32004

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32004

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexLPe32004

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

EmulexLPe32004

12.0.193.13 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

11 FCoE 4 Ports SmartIO10Gbps FCoE

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 1

12 FCoE 4 Ports SmartIO10Gbps FCoE

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 1

13 FCoE 4 Ports SmartIO10Gbps FCoE

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 1

14 FCoE 4 Ports SmartIO10Gbps FCoE

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 1

67

Page 68: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

15 FCoE 4 Ports SmartIO10Gbps FCoE

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 1

16 iSCSI iSCSI 10GE DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

GenericVendor NIC1/10GbE

UltraPath OceanStor5300F V5

V500R007 1

17 iSCSI iSCSI 10GE FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

GenericVendor NIC1/10GbE

UltraPath OceanStor5300F V5

V500R007 1

18 iSCSI iSCSI 10GE HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

GenericVendor NIC1/10GbE

UltraPath OceanStor5300F V5

V500R007 1

19 iSCSI iSCSI 10GE Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

GenericVendor NIC1/10GbE

UltraPath OceanStor5300F V5

V500R007 1

20 iSCSI iSCSI 10GE IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

GenericVendor NIC1/10GbE

UltraPath OceanStor5300F V5

V500R007 1

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 iSCSI iSCSI 10GE Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

GenericVendor NIC1/10GbE

UltraPath OceanStor5300F V5

V500R007 1

2 iSCSI iSCSI 10GE Oracle x86Servers

MicrosoftWindowsServer 2012R2

GenericVendor NIC1/10GbE

UltraPath OceanStor5300F V5

V500R007 1

3 iSCSI iSCSI GE FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

GenericVendor NICGbE

UltraPath OceanStor5300F V5

V500R007 1

4 iSCSI iSCSI GE Oracle x86Servers

MicrosoftWindowsServer 2012R2

GenericVendor NICGbE

UltraPath OceanStor5300F V5

V500R007 1

5 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AJ762A MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AJ762A MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AJ762A MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AJ762A MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AJ762A UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AJ762A 2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 1,4

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AJ762A 2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 1,4

68

Page 69: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

12 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AJ763A MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AJ763A MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AJ763A MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AJ763A MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AJ763A UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AJ763A 2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 1,4

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AJ763A 2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 1,4

19 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HPAJ764A/82Q

MPIO OceanStor5300F V5

V500R007 1,3

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HPAJ764A/82Q

MPIO OceanStor5300F V5

V500R007 1,3

1 Select Windows Server 2012 as the operating system of the host.

2 Set the port topology of the HBA to arbitrated loop in direct-connection networking scenarios.

3 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

4 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HPAJ764A/82Q

MPIO OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HPAJ764A/82Q

MPIO OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HPAJ764A/82Q

UltraPath OceanStor5300F V5

V500R007 2

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HPAJ764A/82Q

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 2,3

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HPAJ764A/82Q

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3

6 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HPAK344A/81Q

MPIO OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HPAK344A/81Q

MPIO OceanStor5300F V5

V500R007 1,2

69

Page 70: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

8 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HPAK344A/81Q

MPIO OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HPAK344A/81Q

MPIO OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HPAK344A/81Q

UltraPath OceanStor5300F V5

V500R007 2

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HPAK344A/81Q

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 2,3

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HPAK344A/81Q

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3

13 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AP769A UltraPath OceanStor5300F V5

V500R007 2,4

14 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP AP770A UltraPath OceanStor5300F V5

V500R007 2,4

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantBlade Series

MicrosoftWindowsServer 2012R2

HP NC553i 6.713.05.00 3.230.20-3532

UltraPath OceanStor5300F V5

V500R007

16 FC 8 Ports 16Gbps FC HP ProLiantBlade Series

MicrosoftWindowsServer 2012R2

HP NC553i 6.713.05.00 3.230.20-3532

UltraPath OceanStor5300F V5

V500R007

17 FC 8 Ports 8Gbps FC HP ProLiantBlade Series

MicrosoftWindowsServer 2012R2

HP NC553i 6.713.05.00 3.230.20-3532

UltraPath OceanStor5300F V5

V500R007

18 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP QR558A MPIO OceanStor5300F V5

V500R007 2,5

19 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP QR558A UltraPath OceanStor5300F V5

V500R007 2,6

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP QR558A 2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 2,3

1 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

2 Select Windows Server 2012 as the operating system of the host.

3 The storage system version must be V500R007C30 or later.

4 Set the port type of the storage system to "Point-to-Point" in direct-connection networking scenarios.

5 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

6 The HBA only supports the switch-connection networking scenarios.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP QR558A 2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP QR559A MPIO OceanStor5300F V5

V500R007 1,3

70

Page 71: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

3 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP QR559A UltraPath OceanStor5300F V5

V500R007 1,4

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP QR559A 2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

HP QR559A 2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0485

MPIO OceanStor5300F V5

V500R007 1,5,6

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0485

MPIO OceanStor5300F V5

V500R007 1,5,6

8 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0485

MPIO OceanStor5300F V5

V500R007 1,5,6

9 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0485

MPIO OceanStor5300F V5

V500R007 1,5,6

10 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0485

MPIO OceanStor5300F V5

V500R007 1,5,6

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0485

MPIO OceanStor5300F V5

V500R007 1,5,6

12 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0485

MPIO OceanStor5300F V5

V500R007 1,5,6

13 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0485

MPIO OceanStor5300F V5

V500R007 1,5,6

14 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0485

UltraPath OceanStor5300F V5

V500R007 1,5

15 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0485

UltraPath OceanStor5300F V5

V500R007 1,5

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0485

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0485

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0485

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0485

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,5,6

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

3 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

4 The HBA only supports the switch-connection networking scenarios.

5 Set the port topology of the HBA to arbitrated loop in direct-connection networking scenarios.

71

Page 72: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

6 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0494

UltraPath OceanStor5300F V5

V500R007 1,3

9 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0494

UltraPath OceanStor5300F V5

V500R007 1,3

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0494

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 3,4

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0494

2.74.214.004 2.01A11 MPIO OceanStor5300F V5

V500R007 3,4

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0494

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 3,4

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0494

2.74.214.004 2.01A11 UltraPath OceanStor5300F V5

V500R007 3,4

14 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0501

MPIO OceanStor5300F V5

V500R007 2,3

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0501

MPIO OceanStor5300F V5

V500R007 2,3

16 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0501

MPIO OceanStor5300F V5

V500R007 2,3

17 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0501

MPIO OceanStor5300F V5

V500R007 2,3

72

Page 73: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

18 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0501

MPIO OceanStor5300F V5

V500R007 2,3

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0501

MPIO OceanStor5300F V5

V500R007 2,3

20 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0501

MPIO OceanStor5300F V5

V500R007 2,3

1 Set the port topology of the HBA to arbitrated loop in direct-connection networking scenarios.

2 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

3 Select Windows Server 2012 as the operating system of the host.

4 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0501

MPIO OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 2

3 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 2

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0501

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 2,3

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0501

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 2,3

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0501

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0501

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3

8 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2

73

Page 74: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

14 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 2

17 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 2

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0510

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 2,3

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0510

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 2,3

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM42D0510

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3

1 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

2 Select Windows Server 2012 as the operating system of the host.

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM42D0510

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM46M6049

UltraPath OceanStor5300F V5

V500R007 1,3

3 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM46M6049

UltraPath OceanStor5300F V5

V500R007 1,3

4 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM46M6050

UltraPath OceanStor5300F V5

V500R007 1,3

5 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM46M6050

UltraPath OceanStor5300F V5

V500R007 1,3

6 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM81Y1655

MPIO OceanStor5300F V5

V500R007 1,4

7 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM81Y1655

MPIO OceanStor5300F V5

V500R007 1,4

8 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM81Y1655

UltraPath OceanStor5300F V5

V500R007 1,5

9 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM81Y1655

UltraPath OceanStor5300F V5

V500R007 1,5

74

Page 75: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM81Y1655

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM81Y1655

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM81Y1655

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM81Y1655

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM81Y1662

MPIO OceanStor5300F V5

V500R007 1,4

15 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM81Y1662

MPIO OceanStor5300F V5

V500R007 1,4

16 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM81Y1662

UltraPath OceanStor5300F V5

V500R007 1,5

17 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM81Y1662

UltraPath OceanStor5300F V5

V500R007 1,5

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM81Y1662

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM81Y1662

2.74.214.004 11.2.156.27 MPIO OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

IBM81Y1662

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

3 Set the port type of the storage system to "Point-to-Point" in direct-connection networking scenarios.

4 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

5 The HBA only supports the switch-connection networking scenarios.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

IBM81Y1662

2.74.214.004 11.2.156.27 UltraPath OceanStor5300F V5

V500R007 1,2

2 iSCSI iSCSI 10GE DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007

3 iSCSI iSCSI GE DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007

4 iSCSI iSCSI 10GE FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007

5 iSCSI iSCSI GE FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007

75

Page 76: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

6 iSCSI iSCSI 10GE HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007

7 iSCSI iSCSI GE HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007

8 iSCSI iSCSI 10GE Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007

9 iSCSI iSCSI GE Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007

10 iSCSI iSCSI 10GE IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007

11 iSCSI iSCSI GE IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007

12 iSCSI iSCSI 10GE Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007

13 iSCSI iSCSI GE Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007

14 iSCSI iSCSI 10GE Oracle x86Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007

15 iSCSI iSCSI GE Oracle x86Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

UltraPath OceanStor5300F V5

V500R007

16 iSCSI iSCSI 10GE DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

3.4.47.2 UltraPath OceanStor5300F V5

V500R007

17 iSCSI iSCSI 10GE HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

3.4.47.2 UltraPath OceanStor5300F V5

V500R007

18 iSCSI iSCSI 10GE Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

3.4.47.2 UltraPath OceanStor5300F V5

V500R007

19 iSCSI iSCSI 10GE IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

3.4.47.2 UltraPath OceanStor5300F V5

V500R007

20 iSCSI iSCSI 10GE Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

Intel X520-SR2

3.4.47.2 UltraPath OceanStor5300F V5

V500R007

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 iSCSI iSCSI 10GE Oracle x86Servers

MicrosoftWindowsServer 2012R2

Intel X520-SR2

3.4.47.2 UltraPath OceanStor5300F V5

V500R007

2 iSCSI 2 Ports 40Gbps ETH DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

Intel XL710-QDA2

MPIO OceanStor5300F V5

V500R007 1,2

76

Page 77: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

3 iSCSI 2 Ports 40Gbps ETH HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

Intel XL710-QDA2

MPIO OceanStor5300F V5

V500R007 1,2

4 iSCSI 2 Ports 40Gbps ETH Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

Intel XL710-QDA2

MPIO OceanStor5300F V5

V500R007 1,2

5 iSCSI 2 Ports 40Gbps ETH IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

Intel XL710-QDA2

MPIO OceanStor5300F V5

V500R007 1,2

6 iSCSI 2 Ports 40Gbps ETH Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

Intel XL710-QDA2

MPIO OceanStor5300F V5

V500R007 1,2

7 iSCSI 2 Ports 40Gbps ETH Oracle x86Servers

MicrosoftWindowsServer 2012R2

Intel XL710-QDA2

MPIO OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

9 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3,4

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

11 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

12 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

13 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

14 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

15 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

16 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

17 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3,4

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

19 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

20 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogic BR-815

UltraPath OceanStor5300F V5

V500R007 1,3

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

3 Set the port type of the storage system to "Point-to-Point" in direct-connection networking scenarios.

4 Set the FLOGI latency to 500 µs for the port that connects the storage device and the host HBA in direct-connection networkingscenarios. The CLI command is: change port fc FC Port ID flogin_delay_times=500.

77

Page 78: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogic BR-825

UltraPath OceanStor5300F V5

V500R007 1,2

14 iSCSI 4 Ports SmartIO25Gbps ETH

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicFastLinQQL45611HLCU

MPIO OceanStor5300F V5

V500R007 2,4

15 iSCSI 4 Ports SmartIO25Gbps ETH

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicFastLinQQL45611HLCU

MPIO OceanStor5300F V5

V500R007 2,4

16 iSCSI 4 Ports SmartIO25Gbps ETH

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicFastLinQQL45611HLCU

MPIO OceanStor5300F V5

V500R007 2,4

17 iSCSI 4 Ports SmartIO25Gbps ETH

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicFastLinQQL45611HLCU

MPIO OceanStor5300F V5

V500R007 2,4

18 iSCSI 4 Ports SmartIO25Gbps ETH

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicFastLinQQL45611HLCU

MPIO OceanStor5300F V5

V500R007 2,4

78

Page 79: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

19 iSCSI 4 Ports SmartIO25Gbps ETH

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicFastLinQQL45611HLCU

MPIO OceanStor5300F V5

V500R007 2,4

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 2,4

1 Set the port type of the storage system to "Point-to-Point" in direct-connection networking scenarios.

2 Select Windows Server 2012 as the operating system of the host.

3 Set the FLOGI latency to 500 µs for the port that connects the storage device and the host HBA in direct-connection networkingscenarios. The CLI command is: change port fc FC Port ID flogin_delay_times=500.

4 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,3

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,3

14 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,3

79

Page 80: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

15 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,3

16 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,3

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,3

18 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,3

19 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,3

20 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,3

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

3 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

8 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

80

Page 81: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

11 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

1 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

2 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

2 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

3 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

4 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

6 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

7 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

81

Page 82: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

8 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

10 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

11 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

12 FC 4 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

14 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

15 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

16 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

18 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

19 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

20 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

1 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

2 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

3 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

4 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

82

Page 83: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

6 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

7 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.1.11.3 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.1.11.3 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,3

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

3 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

83

Page 84: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

8 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

84

Page 85: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

2 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 1,2

8 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

10 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

11 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

12 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

14 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

15 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

16 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

85

Page 86: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

18 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

19 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

20 FC 4 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 2

1 Install the KB2919355 and KB3121261 patches in sequence. For details, see https://support.microsoft.com/en-us/help/2919355/windows-rt-8.1,-windows-8.1,-and-windows-server-2012-r2-update-april-2014和“https://support.microsoft.com/en-us/help/3121261/system-fails-back-to-a-host-copy-instead

2 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

2 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

3 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

4 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

6 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

7 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

8 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

10 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

11 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

12 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

14 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

86

Page 87: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

15 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

16 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

1 Select Windows Server 2012 as the operating system of the host.

2 The HBA driver version is 9.1.11.24.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

87

Page 88: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

12 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

1 The HBA driver version is 9.1.11.24.

2 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

3 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

6 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

7 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

88

Page 89: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

9 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

10 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

12 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

13 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

15 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

16 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

18 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

19 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

1 The HBA driver version is 9.1.11.24.

2 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

2 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

5 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

89

Page 90: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

7 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

8 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

10 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

11 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

13 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

14 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

16 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

17 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

19 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

20 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

2 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

3 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007

90

Page 91: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

5 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

6 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

8 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

9 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

11 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

12 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

14 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

15 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

17 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

18 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

20 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

91

Page 92: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

3 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeBlade Series

MicrosoftWindowsServer 2012R2

QLogicQME2572

9.1.113 5.09.00(90d5)

UltraPath OceanStor5300F V5

V500R007

6 FC 8 Ports 16Gbps FC HP ProLiantBlade Series

MicrosoftWindowsServer 2012R2

QLogicQMH2672

UltraPath OceanStor5300F V5

V500R007 1

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 Standardx64 Edition

EmulexLPe32002-M2

11.1.145.16 11.2.156.27,sli-4:2:c

MPIO OceanStor5300F V5

V500R007 2

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 Standardx64 Edition

EmulexLPe32002-M2

11.1.145.16 11.2.156.27,sli-4:2:c

MPIO OceanStor5300F V5

V500R007 2

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 Standardx64 Edition

EmulexLPe32002-M2

11.1.145.16 11.2.156.27,sli-4:2:c

MPIO OceanStor5300F V5

V500R007 2

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 Standardx64 Edition

EmulexLPe32002-M2

11.1.145.16 11.2.156.27,sli-4:2:c

MPIO OceanStor5300F V5

V500R007 2

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 Standardx64 Edition

EmulexLPe32002-M2

11.1.145.16 11.2.156.27,sli-4:2:c

MPIO OceanStor5300F V5

V500R007 2

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 Standardx64 Edition

EmulexLPe32002-M2

11.1.145.16 11.2.156.27,sli-4:2:c

MPIO OceanStor5300F V5

V500R007 2

13 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

DELLF641C

UltraPath OceanStor5300F V5

V500R007 1

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

DELLF641C

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

DELLF641C

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

DELLH144C

UltraPath OceanStor5300F V5

V500R007 1

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

DELLH144C

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

DELLH144C

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

92

Page 93: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

19 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe1105

MPIO OceanStor5300F V5

V500R007 1,4,5

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe1105

MPIO OceanStor5300F V5

V500R007 1,3,4,5

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

3 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

4 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

5 The OS version of the VM is Windows Server 2012.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe1105

MPIO OceanStor5300F V5

V500R007 1,2,3,4

2 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe1105

MPIO OceanStor5300F V5

V500R007 1,2,3,4

3 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe1105

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe1105

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe1105

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe1105

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe1105

MPIO OceanStor5300F V5

V500R007 1,2,3,4

8 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe1105

MPIO OceanStor5300F V5

V500R007 1,2,3,4

9 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe1105

MPIO OceanStor5300F V5

V500R007 1,2,3,4

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16000

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 3,4,5

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16000

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 3,4,5

93

Page 94: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16000

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 3,4,5

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16000

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 3,4,5

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16000

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 3,4,5

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16000

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 3,4,5

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16000

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 3,4,5

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16000

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 3,4,5

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16000

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 3,4,5

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16000

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 3,4,5

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16000

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 3,4,5

1 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

2 The OS version of the VM is Windows Server 2012.

3 Select Windows Server 2012 as the operating system of the host.

4 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

5 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16000

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16000B

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16000B

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16000B

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

94

Page 95: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16000B

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16000B

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16000B

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16000B

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16000B

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16000B

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16000B

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16000B

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16000B

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

1 Select Windows Server 2012 as the operating system of the host.

2 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

95

Page 96: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

96

Page 97: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

1 Select Windows Server 2012 as the operating system of the host.

2 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

97

Page 98: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPe16002B

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16004

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16004

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

1 Select Windows Server 2012 as the operating system of the host.

2 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

98

Page 99: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16004

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16004

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16004

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16004

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16004

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16004

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16004

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16004

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16004

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

EmulexLPE16004

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

HP 710608-B21

MPIO OceanStor5300F V5

V500R007 1,4,5

12 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

HPAJ764A/82Q

UltraPath OceanStor5300F V5

V500R007 1

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

HPAJ764A/82Q

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

HPAJ764A/82Q

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

HPAK344A/81Q

UltraPath OceanStor5300F V5

V500R007 1

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

HPAK344A/81Q

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

99

Page 100: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

HPAK344A/81Q

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

HP QR558A 12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

HP QR558A 12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

HP QR559A 12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

1 Select Windows Server 2012 as the operating system of the host.

2 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

3 The storage system version must be V500R007C30 or later.

4 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

5 The OS version of the VM is Windows Server 2012.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

HP QR559A 12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1

3 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

IBM42D0501

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

IBM42D0501

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

IBM42D0501

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

IBM42D0501

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1

9 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1

100

Page 101: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

IBM42D0510

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

IBM42D0510

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

IBM42D0510

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

IBM42D0510

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

IBM81Y1655

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

IBM81Y1655

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

IBM81Y1655

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

IBM81Y1655

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

IBM81Y1662

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

IBM81Y1662

12.0.193.13 10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

IBM81Y1662

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

1 Select Windows Server 2012 as the operating system of the host.

2 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

IBM81Y1662

12.0.193.13 10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

101

Page 102: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

15 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

102

Page 103: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

19 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

20 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

1 Select Windows Server 2012 as the operating system of the host.

2 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

2 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

3 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

103

Page 104: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.1.11.3 5.09.00 MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.1.11.3 5.09.00 UltraPath OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

20 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

1 Select Windows Server 2012 as the operating system of the host.

2 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

104

Page 105: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

5 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

6 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

7 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1

8 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQMH2672

MPIO OceanStor5300F V5

V500R007 1,3,4

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQMH2672

MPIO OceanStor5300F V5

V500R007 1,2,3,4

14 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQMH2672

MPIO OceanStor5300F V5

V500R007 1,2,3,4

15 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQMH2672

MPIO OceanStor5300F V5

V500R007 1,2,3,4

16 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQMH2672

MPIO OceanStor5300F V5

V500R007 1,3,4

17 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQMH2672

MPIO OceanStor5300F V5

V500R007 1,3,4

18 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQMH2672

MPIO OceanStor5300F V5

V500R007 1,3,4

19 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQMH2672

MPIO OceanStor5300F V5

V500R007 1,3,4

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQMH2672

MPIO OceanStor5300F V5

V500R007 1,2,3,4

1 Select Windows Server 2012 as the operating system of the host.

2 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

105

Page 106: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

3 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

4 The OS version of the VM is Windows Server 2012.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQMH2672

MPIO OceanStor5300F V5

V500R007 1,2,3,4

2 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012R2 withHyper-V

QLogicQMH2672

MPIO OceanStor5300F V5

V500R007 1,2,3,4

3 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

DELLF641C

MPIO OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

DELLF641C

UltraPath OceanStor5300F V5

V500R007 4,5

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

DELLF641C

UltraPath OceanStor5300F V5

V500R007 4,5

6 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

DELLF641C

UltraPath OceanStor5300F V5

V500R007 4,5

7 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

DELLF641C

UltraPath OceanStor5300F V5

V500R007 4,5

8 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

DELLH144C

MPIO OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

DELLH144C

UltraPath OceanStor5300F V5

V500R007 4,5

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

DELLH144C

UltraPath OceanStor5300F V5

V500R007 4,5

11 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

DELLH144C

UltraPath OceanStor5300F V5

V500R007 4,5

12 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

DELLH144C

UltraPath OceanStor5300F V5

V500R007 4,5

13 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

DELLLPe12000-E

MPIO OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

DELLLPe12002-E

MPIO OceanStor5300F V5

V500R007 1,2

106

Page 107: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

15 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,4

17 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,4

18 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,4

19 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2

1 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

2 The OS version of the VM is Windows Server 2012.

3 Select Windows Server 2012 as the operating system of the host.

4 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

5 Install the KB2996802 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/2996802/trim-and-unmap-activities-for-thin-provisioning-on-one-volume-block-all-activities-on-other-volumes.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2

107

Page 108: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantBlade Series

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe1205-HP

11.1.145.16 2.03X6 MPIO OceanStor5300F V5

V500R007 2,3

18 FC 8 Ports 16Gbps FC HP ProLiantBlade Series

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe1205-HP

11.1.145.16 2.03X6 MPIO OceanStor5300F V5

V500R007 2,3

19 FC 8 Ports 8Gbps FC HP ProLiantBlade Series

MicrosoftWindowsServer 2012with Hyper-V

EmulexLPe1205-HP

11.1.145.16 2.03X6 MPIO OceanStor5300F V5

V500R007 2,3

20 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HP AJ762A MPIO OceanStor5300F V5

V500R007 1,2

1 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

2 The OS version of the VM is Windows Server 2012.

3 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

108

Page 109: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HP AJ763A MPIO OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HP AJ763B MPIO OceanStor5300F V5

V500R007

3 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HP AJ763B MPIO OceanStor5300F V5

V500R007

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HP AJ763B MPIO OceanStor5300F V5

V500R007

5 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HP AJ763B MPIO OceanStor5300F V5

V500R007

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HP AJ763B MPIO OceanStor5300F V5

V500R007

7 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HP AJ763B MPIO OceanStor5300F V5

V500R007

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HP AJ763B MPIO OceanStor5300F V5

V500R007

9 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HP AJ763B MPIO OceanStor5300F V5

V500R007

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

HP AJ763B MPIO OceanStor5300F V5

V500R007

11 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

HP AJ763B MPIO OceanStor5300F V5

V500R007

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

HP AJ763B MPIO OceanStor5300F V5

V500R007

13 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

HP AJ763B MPIO OceanStor5300F V5

V500R007

14 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HPAJ764A/82Q

MPIO OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HPAJ764A/82Q

UltraPath OceanStor5300F V5

V500R007 3,4

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HPAJ764A/82Q

UltraPath OceanStor5300F V5

V500R007 3,4

109

Page 110: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

17 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HPAJ764A/82Q

UltraPath OceanStor5300F V5

V500R007 3,4

18 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HPAJ764A/82Q

UltraPath OceanStor5300F V5

V500R007 3,4

19 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HPAK344A/81Q

MPIO OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HPAK344A/81Q

UltraPath OceanStor5300F V5

V500R007 3,4

1 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

2 The OS version of the VM is Windows Server 2012.

3 Install the KB2996802 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/2996802/trim-and-unmap-activities-for-thin-provisioning-on-one-volume-block-all-activities-on-other-volumes.

4 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HPAK344A/81Q

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HPAK344A/81Q

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

HPAK344A/81Q

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0485

MPIO OceanStor5300F V5

V500R007 3,4

5 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0485

MPIO OceanStor5300F V5

V500R007 3,4

6 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0494

MPIO OceanStor5300F V5

V500R007 3,4

7 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0494

MPIO OceanStor5300F V5

V500R007 3,4

8 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0501

MPIO OceanStor5300F V5

V500R007 3,4

9 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0501

MPIO OceanStor5300F V5

V500R007 3,4

110

Page 111: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

10 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0510

MPIO OceanStor5300F V5

V500R007 3,4

19 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0510

MPIO OceanStor5300F V5

V500R007 3,4

20 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB2996802 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/2996802/trim-and-unmap-activities-for-thin-provisioning-on-one-volume-block-all-activities-on-other-volumes.

2 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

3 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

4 The OS version of the VM is Windows Server 2012.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1,2

111

Page 112: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

3 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 3,4

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2,3,4

10 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2,3,4

11 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2,3,4

12 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 3,4

13 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 3,4

14 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 3,4

15 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 3,4

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2,3,4

17 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2,3,4

18 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2,3,4

112

Page 113: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

19 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB2996802 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/2996802/trim-and-unmap-activities-for-thin-provisioning-on-one-volume-block-all-activities-on-other-volumes.

2 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

3 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

4 The OS version of the VM is Windows Server 2012.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 4 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

113

Page 114: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB2996802 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/2996802/trim-and-unmap-activities-for-thin-provisioning-on-one-volume-block-all-activities-on-other-volumes.

2 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

114

Page 115: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

5 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2560

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 3,4

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2,3,4

9 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2,3,4

10 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2,3,4

11 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 3,4

12 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 3,4

13 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 3,4

14 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 3,4

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2,3,4

16 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2,3,4

17 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 MPIO OceanStor5300F V5

V500R007 2,3,4

18 FC 4 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB2996802 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/2996802/trim-and-unmap-activities-for-thin-provisioning-on-one-volume-block-all-activities-on-other-volumes.

115

Page 116: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

2 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

3 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

4 The OS version of the VM is Windows Server 2012.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

116

Page 117: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

14 FC 4 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB2996802 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/2996802/trim-and-unmap-activities-for-thin-provisioning-on-one-volume-block-all-activities-on-other-volumes.

2 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2562

9.2.6.20 8.05.00 UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 2

117

Page 118: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 2

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 2

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 2

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 2

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 2

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 2

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 2

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 2

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 2

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 2

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 2

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 2

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2012with Hyper-V

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 2

20 iSCSI 2 Ports 40Gbps ETH DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

BroadcomNetXTremeP225p

212.0.89.0 MPIO OceanStor5300F V5

V500R007 3,4

1 Install the KB2996802 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/2996802/trim-and-unmap-activities-for-thin-provisioning-on-one-volume-block-all-activities-on-other-volumes.

2 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

3 Select Windows Server 2012 as the operating system of the host.

4 The storage system version must be V500R007C30 or later.

118

Page 119: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 iSCSI 4 Ports SmartIO25Gbps ETH

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

BroadcomNetXTremeP225p

212.0.89.0 MPIO OceanStor5300F V5

V500R007 1,2

2 iSCSI 2 Ports 40Gbps ETH HP ProLiantRack Servers

MicrosoftWindowsServer 2016

BroadcomNetXTremeP225p

212.0.89.0 MPIO OceanStor5300F V5

V500R007 1,2

3 iSCSI 4 Ports SmartIO25Gbps ETH

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

BroadcomNetXTremeP225p

212.0.89.0 MPIO OceanStor5300F V5

V500R007 1,2

4 iSCSI 2 Ports 40Gbps ETH Huawei RHRack Servers

MicrosoftWindowsServer 2016

BroadcomNetXTremeP225p

212.0.89.0 MPIO OceanStor5300F V5

V500R007 1,2

5 iSCSI 4 Ports SmartIO25Gbps ETH

Huawei RHRack Servers

MicrosoftWindowsServer 2016

BroadcomNetXTremeP225p

212.0.89.0 MPIO OceanStor5300F V5

V500R007 1,2

6 iSCSI 2 Ports 40Gbps ETH IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

BroadcomNetXTremeP225p

212.0.89.0 MPIO OceanStor5300F V5

V500R007 1,2

7 iSCSI 4 Ports SmartIO25Gbps ETH

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

BroadcomNetXTremeP225p

212.0.89.0 MPIO OceanStor5300F V5

V500R007 1,2

8 iSCSI 2 Ports 40Gbps ETH Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

BroadcomNetXTremeP225p

212.0.89.0 MPIO OceanStor5300F V5

V500R007 1,2

9 iSCSI 4 Ports SmartIO25Gbps ETH

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

BroadcomNetXTremeP225p

212.0.89.0 MPIO OceanStor5300F V5

V500R007 1,2

10 iSCSI 2 Ports 40Gbps ETH Oracle x86Servers

MicrosoftWindowsServer 2016

BroadcomNetXTremeP225p

212.0.89.0 MPIO OceanStor5300F V5

V500R007 1,2

11 iSCSI 4 Ports SmartIO25Gbps ETH

Oracle x86Servers

MicrosoftWindowsServer 2016

BroadcomNetXTremeP225p

212.0.89.0 MPIO OceanStor5300F V5

V500R007 1,2

12 iSCSI 2 Ports 100GbpsETH

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

ChelsioT62100-CR

6.11.4.0 MPIO OceanStor5300F V5

V500R007 1,2

13 iSCSI 2 Ports 100GbpsETH

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

ChelsioT62100-CR

6.11.4.0 MPIO OceanStor5300F V5

V500R007 1,2

14 iSCSI 2 Ports 100GbpsETH

Huawei RHRack Servers

MicrosoftWindowsServer 2016

ChelsioT62100-CR

6.11.4.0 MPIO OceanStor5300F V5

V500R007 1,2

15 iSCSI 2 Ports 100GbpsETH

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

ChelsioT62100-CR

6.11.4.0 MPIO OceanStor5300F V5

V500R007 1,2

16 iSCSI 2 Ports 100GbpsETH

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

ChelsioT62100-CR

6.11.4.0 MPIO OceanStor5300F V5

V500R007 1,2

17 iSCSI 2 Ports 100GbpsETH

Oracle x86Servers

MicrosoftWindowsServer 2016

ChelsioT62100-CR

6.11.4.0 MPIO OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLDH226

MPIO OceanStor5300F V5

V500R007 1,3,4

19 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLDH226

MPIO OceanStor5300F V5

V500R007 1,3,4

20 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLDH226

MPIO OceanStor5300F V5

V500R007 1,3,4

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

3 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

4 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

119

Page 120: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLF641C

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLF641C

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLF641C

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLF641C

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLF641C

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLF641C

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLF641C

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLF641C

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2,5

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELL FF340 MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELL FF340 MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELL FF340 MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLFH590

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLFH590

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLFH590

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLH144C

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLH144C

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLH144C

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLH144C

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLH144C

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLH144C

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

5 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

120

Page 121: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLH144C

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLH144C

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3,5

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe11002-E

MPIO OceanStor5300F V5

V500R007 2,3,4

4 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe11002-E

MPIO OceanStor5300F V5

V500R007 2,3,4

5 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe11002-E

MPIO OceanStor5300F V5

V500R007 2,3,4

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe12000-E

MPIO OceanStor5300F V5

V500R007 2,3,4

7 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe12000-E

MPIO OceanStor5300F V5

V500R007 2,3,4

8 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe12000-E

MPIO OceanStor5300F V5

V500R007 2,3,4

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe12000-E

UltraPath OceanStor5300F V5

V500R007 2,3

10 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe12000-E

UltraPath OceanStor5300F V5

V500R007 2,3

11 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe12000-E

UltraPath OceanStor5300F V5

V500R007 2,3

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe12002-E

MPIO OceanStor5300F V5

V500R007 2,3,4

13 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe12002-E

MPIO OceanStor5300F V5

V500R007 2,3,4

14 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe12002-E

MPIO OceanStor5300F V5

V500R007 2,3,4

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe12002-E

UltraPath OceanStor5300F V5

V500R007 2,3

16 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe12002-E

UltraPath OceanStor5300F V5

V500R007 2,3

17 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELLLPe12002-E

UltraPath OceanStor5300F V5

V500R007 2,3

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELL PF323 MPIO OceanStor5300F V5

V500R007 2,3,4

19 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELL PF323 MPIO OceanStor5300F V5

V500R007 2,3,4

20 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

DELL PF323 MPIO OceanStor5300F V5

V500R007 2,3,4

1 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

2 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

3 Select Windows Server 2012 as the operating system of the host.

4 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

5 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

121

Page 122: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLP11000

MPIO OceanStor5300F V5

V500R007 1,2,3

122

Page 123: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLP11002

MPIO OceanStor5300F V5

V500R007 1,2,3

123

Page 124: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe11000

MPIO OceanStor5300F V5

V500R007 1,2,3

124

Page 125: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe11002

MPIO OceanStor5300F V5

V500R007 1,2,3

125

Page 126: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3

126

Page 127: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe12000

UltraPath OceanStor5300F V5

V500R007 1,2

127

Page 128: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3

128

Page 129: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe12002

UltraPath OceanStor5300F V5

V500R007 1,2

129

Page 130: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe15002B

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16000

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

130

Page 131: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16000

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16000

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16000

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe16000

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe16000

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16000

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16000

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16000

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16000

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe16000

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe16000

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16000B

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16000B

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16000B

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16000B

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPE16000B

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPE16000B

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16000B

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16000B

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16000B

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16000B

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

131

Page 132: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPE16000B

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPE16000B

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe16002

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe16002

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 The storage system version must be V500R007C30 or later.

4 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe16002

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe16002

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

7 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

8 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

10 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

11 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

132

Page 133: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

13 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

14 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

16 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

17 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

19 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

20 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,4

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 The storage system version must be V500R007C30 or later.

4 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

133

Page 134: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

14 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe16002B

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

134

Page 135: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe16002B

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe16002B

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16004

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16004

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16004

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16004

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPE16004

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPE16004

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16004

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16004

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16004

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPE16004

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPE16004

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPE16004

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32000

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,4

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32000

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,4

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32000

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,4

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32000

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,4

135

Page 136: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe32000

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,4

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe32000

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,4

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32000

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,4

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32000

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,4

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32000

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,4

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32000

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe32000

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe32000

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

136

Page 137: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

17 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,3

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,3

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,3

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,3

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe32002

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,3

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,3

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe32002

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe32002

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32004

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,3

137

Page 138: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32004

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,3

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32004

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,3

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32004

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 2,3

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe32004

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe32004

11.4.204.8 11.2.156.40 MPIO OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32004

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32004

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32004

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexLPe32004

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexLPe32004

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexLPe32004

11.4.204.8 11.2.156.40 UltraPath OceanStor5300F V5

V500R007 1,2,3

9 FCoE 4 Ports SmartIO10Gbps FCoE

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 1,3

10 FCoE 4 Ports SmartIO10Gbps FCoE

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 1,3

11 FCoE 4 Ports SmartIO10Gbps FCoE

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 1,3

12 FCoE 4 Ports SmartIO10Gbps FCoE

Huawei RHRack Servers

MicrosoftWindowsServer 2016

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 1,3

13 FCoE 4 Ports SmartIO10Gbps FCoE

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 1,3

14 FCoE 4 Ports SmartIO10Gbps FCoE

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 1,3

15 FCoE 4 Ports SmartIO10Gbps FCoE

Oracle x86Servers

MicrosoftWindowsServer 2016

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 1,3

16 iSCSI iSCSI 10GE DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

GenericVendor NIC10GbE

MPIO OceanStor5300F V5

V500R007 1,3,4

17 iSCSI iSCSI 10GE FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

GenericVendor NIC10GbE

MPIO OceanStor5300F V5

V500R007 1,3,4

18 iSCSI iSCSI 10GE HP ProLiantRack Servers

MicrosoftWindowsServer 2016

GenericVendor NIC10GbE

MPIO OceanStor5300F V5

V500R007 1,3,4

138

Page 139: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

19 iSCSI iSCSI 10GE Huawei RHRack Servers

MicrosoftWindowsServer 2016

GenericVendor NIC10GbE

MPIO OceanStor5300F V5

V500R007 1,3,4

20 iSCSI iSCSI 10GE IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

GenericVendor NIC10GbE

MPIO OceanStor5300F V5

V500R007 1,3,4

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

3 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

4 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 iSCSI iSCSI 10GE Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

GenericVendor NIC10GbE

MPIO OceanStor5300F V5

V500R007 1,2,3

2 iSCSI iSCSI 10GE Oracle x86Servers

MicrosoftWindowsServer 2016

GenericVendor NIC10GbE

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAB429A/FC1143

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAB429A/FC1143

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAB429A/FC1143

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAE311A/FC1142SR

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAE311A/FC1142SR

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAE311A/FC1142SR

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAE312A/FC1242SR

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAE312A/FC1242SR

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAE312A/FC1242SR

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAE369A/FC1243

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAE369A/FC1243

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAE369A/FC1243

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP AJ762A MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP AJ762A MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP AJ762A MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP AJ762A UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP AJ762A UltraPath OceanStor5300F V5

V500R007 1,2

139

Page 140: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

20 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP AJ762A UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP AJ763A MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP AJ763A MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP AJ763A MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP AJ763A UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP AJ763A UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP AJ763A UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAJ764A/82Q

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAJ764A/82Q

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAJ764A/82Q

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAJ764A/82Q

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAJ764A/82Q

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAJ764A/82Q

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAJ764A/82Q

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAJ764A/82Q

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2,5

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAK344A/81Q

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAK344A/81Q

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAK344A/81Q

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAK344A/81Q

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAK344A/81Q

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAK344A/81Q

UltraPath OceanStor5300F V5

V500R007 1,2

140

Page 141: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

5 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAK344A/81Q

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPAK344A/81Q

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3,5

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPFC2242SR

MPIO OceanStor5300F V5

V500R007 2,3,4

4 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPFC2242SR

MPIO OceanStor5300F V5

V500R007 2,3,4

5 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HPFC2242SR

MPIO OceanStor5300F V5

V500R007 2,3,4

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP FC2243 MPIO OceanStor5300F V5

V500R007 2,3,4

7 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP FC2243 MPIO OceanStor5300F V5

V500R007 2,3,4

8 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP FC2243 MPIO OceanStor5300F V5

V500R007 2,3,4

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP QR558A 11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 2,3,4,5

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP QR558A 11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 2,3,5

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP QR559A 11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 2,3,4,5

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

HP QR559A 11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 2,3,5

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM39M5894

MPIO OceanStor5300F V5

V500R007 2,3,4

14 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM39M5894

MPIO OceanStor5300F V5

V500R007 2,3,4

15 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM39M5894

MPIO OceanStor5300F V5

V500R007 2,3,4

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM39M5894

MPIO OceanStor5300F V5

V500R007 2,3,4

17 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM39M5894

MPIO OceanStor5300F V5

V500R007 2,3,4

18 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM39M5894

MPIO OceanStor5300F V5

V500R007 2,3,4

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM39M5895

MPIO OceanStor5300F V5

V500R007 2,3,4

20 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM39M5895

MPIO OceanStor5300F V5

V500R007 2,3,4

141

Page 142: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

2 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

3 Select Windows Server 2012 as the operating system of the host.

4 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

5 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM39M5895

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM39M5895

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM39M5895

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM39M5895

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM39R6525

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM39R6525

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM39R6525

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM39R6525

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM39R6525

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM39R6525

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM39R6527

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM39R6527

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM39R6527

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM39R6527

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM39R6527

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM39R6527

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42C2069

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42C2069

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42C2069

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42C2069

MPIO OceanStor5300F V5

V500R007 1,2,3

142

Page 143: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42C2069

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42C2069

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42C2071

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42C2071

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42C2071

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42C2071

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42C2071

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42C2071

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0405

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0405

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0405

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0405

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0405

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0405

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0407

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0407

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0407

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0407

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0407

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0407

MPIO OceanStor5300F V5

V500R007 1,2,3

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

143

Page 144: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0485

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0485

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0485

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0485

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0485

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0485

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0485

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0485

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0485

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0485

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0485

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0485

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0494

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0494

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

144

Page 145: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0494

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0494

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0494

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0494

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0501

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0501

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0501

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0501

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0501

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0501

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0501

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0501

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0501

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0501

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2,5

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0501

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2,5

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

5 The storage system version must be V500R007C30 or later.

145

Page 146: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0510

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0510

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0510

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM42D0510

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2,5

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM42D0510

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2,5

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM81Y1655

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,5

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM81Y1655

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,5

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM81Y1655

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,5

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM81Y1655

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,5

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

5 The storage system version must be V500R007C30 or later.

146

Page 147: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM81Y1662

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM81Y1662

11.0.247.8000

10.4.255.23 MPIO OceanStor5300F V5

V500R007 1,2,3,4

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

IBM81Y1662

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

IBM81Y1662

11.0.247.8000

10.4.255.23 UltraPath OceanStor5300F V5

V500R007 1,2,4

5 iSCSI 2 Ports 40Gbps ETH DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

Intel XL710-QDA2

1.3.115.0 MPIO OceanStor5300F V5

V500R007 2,4

6 iSCSI 2 Ports 40Gbps ETH HP ProLiantRack Servers

MicrosoftWindowsServer 2016

Intel XL710-QDA2

1.3.115.0 MPIO OceanStor5300F V5

V500R007 2,4

7 iSCSI 2 Ports 40Gbps ETH Huawei RHRack Servers

MicrosoftWindowsServer 2016

Intel XL710-QDA2

1.3.115.0 MPIO OceanStor5300F V5

V500R007 2,4

8 iSCSI 2 Ports 40Gbps ETH IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

Intel XL710-QDA2

1.3.115.0 MPIO OceanStor5300F V5

V500R007 2,4

9 iSCSI 2 Ports 40Gbps ETH Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

Intel XL710-QDA2

1.3.115.0 MPIO OceanStor5300F V5

V500R007 2,4

10 iSCSI 2 Ports 40Gbps ETH Oracle x86Servers

MicrosoftWindowsServer 2016

Intel XL710-QDA2

1.3.115.0 MPIO OceanStor5300F V5

V500R007 2,4

11 iSCSI 4 Ports SmartIO25Gbps ETH

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

MellanoxMCX4121A-ACAT

1.33.14901.0 14.22.1002 MPIO OceanStor5300F V5

V500R007 4

12 iSCSI 4 Ports SmartIO25Gbps ETH

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

MellanoxMCX4121A-ACAT

1.33.14901.0 14.22.1002 MPIO OceanStor5300F V5

V500R007 4

13 iSCSI 4 Ports SmartIO25Gbps ETH

Huawei RHRack Servers

MicrosoftWindowsServer 2016

MellanoxMCX4121A-ACAT

1.33.14901.0 14.22.1002 MPIO OceanStor5300F V5

V500R007 4

14 iSCSI 4 Ports SmartIO25Gbps ETH

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

MellanoxMCX4121A-ACAT

1.33.14901.0 14.22.1002 MPIO OceanStor5300F V5

V500R007 4

15 iSCSI 4 Ports SmartIO25Gbps ETH

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

MellanoxMCX4121A-ACAT

1.33.14901.0 14.22.1002 MPIO OceanStor5300F V5

V500R007 4

16 iSCSI 4 Ports SmartIO25Gbps ETH

Oracle x86Servers

MicrosoftWindowsServer 2016

MellanoxMCX4121A-ACAT

1.33.14901.0 14.22.1002 MPIO OceanStor5300F V5

V500R007 4

17 iSCSI 2 Ports 100GbpsETH

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

MellanoxMCX416A-CCAT

1.33.14901.0 12.23.1020 MPIO OceanStor5300F V5

V500R007 4

18 iSCSI 2 Ports 100GbpsETH

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

MellanoxMCX416A-CCAT

1.33.14901.0 12.23.1020 MPIO OceanStor5300F V5

V500R007 4

19 iSCSI 2 Ports 100GbpsETH

Huawei RHRack Servers

MicrosoftWindowsServer 2016

MellanoxMCX416A-CCAT

1.33.14901.0 12.23.1020 MPIO OceanStor5300F V5

V500R007 4

20 iSCSI 2 Ports 100GbpsETH

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

MellanoxMCX416A-CCAT

1.33.14901.0 12.23.1020 MPIO OceanStor5300F V5

V500R007 4

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 The storage system version must be V500R007C30 or later.

147

Page 148: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 iSCSI 2 Ports 100GbpsETH

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

MellanoxMCX416A-CCAT

1.33.14901.0 12.23.1020 MPIO OceanStor5300F V5

V500R007 1

2 iSCSI 2 Ports 100GbpsETH

Oracle x86Servers

MicrosoftWindowsServer 2016

MellanoxMCX416A-CCAT

1.33.14901.0 12.23.1020 MPIO OceanStor5300F V5

V500R007 1

3 iSCSI 4 Ports SmartIO25Gbps ETH

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL41212HLCU

8.37.6.0 mfw8.30.10.139storm8.15.3.0

MPIO OceanStor5300F V5

V500R007 1

4 iSCSI 4 Ports SmartIO25Gbps ETH

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL41212HLCU

8.37.6.0 mfw8.30.10.139storm8.15.3.0

MPIO OceanStor5300F V5

V500R007 1

5 iSCSI 4 Ports SmartIO25Gbps ETH

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL41212HLCU

8.37.6.0 mfw8.30.10.139storm8.15.3.0

MPIO OceanStor5300F V5

V500R007 1

6 iSCSI 4 Ports SmartIO25Gbps ETH

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL41212HLCU

8.37.6.0 mfw8.30.10.139storm8.15.3.0

MPIO OceanStor5300F V5

V500R007 1

7 iSCSI 4 Ports SmartIO25Gbps ETH

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicFastLinQQL41212HLCU

8.37.6.0 mfw8.30.10.139storm8.15.3.0

MPIO OceanStor5300F V5

V500R007 1

8 iSCSI 4 Ports SmartIO25Gbps ETH

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL41212HLCU

8.37.6.0 mfw8.30.10.139storm8.15.3.0

MPIO OceanStor5300F V5

V500R007 1

9 iSCSI 4 Ports SmartIO25Gbps ETH

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL45212HLCU

8.37.6.0 MPIO OceanStor5300F V5

V500R007 1,2

10 iSCSI 4 Ports SmartIO25Gbps ETH

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL45212HLCU

8.37.6.0 MPIO OceanStor5300F V5

V500R007 1,2

11 iSCSI 4 Ports SmartIO25Gbps ETH

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL45212HLCU

8.37.6.0 MPIO OceanStor5300F V5

V500R007 1,2

12 iSCSI 4 Ports SmartIO25Gbps ETH

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL45212HLCU

8.37.6.0 MPIO OceanStor5300F V5

V500R007 1,2

13 iSCSI 4 Ports SmartIO25Gbps ETH

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicFastLinQQL45212HLCU

8.37.6.0 MPIO OceanStor5300F V5

V500R007 1,2

14 iSCSI 4 Ports SmartIO25Gbps ETH

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL45212HLCU

8.37.6.0 MPIO OceanStor5300F V5

V500R007 1,2

15 iSCSI 2 Ports 100GbpsETH

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL45611HLCU

8.37.6.0 mfw8.35.41.0storm 8.7.9.0

MPIO OceanStor5300F V5

V500R007 1

16 iSCSI 2 Ports 100GbpsETH

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL45611HLCU

8.37.6.0 mfw8.35.41.0storm 8.7.9.0

MPIO OceanStor5300F V5

V500R007 1

17 iSCSI 2 Ports 100GbpsETH

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL45611HLCU

8.37.6.0 mfw8.35.41.0storm 8.7.9.0

MPIO OceanStor5300F V5

V500R007 1

18 iSCSI 2 Ports 100GbpsETH

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL45611HLCU

8.37.6.0 mfw8.35.41.0storm 8.7.9.0

MPIO OceanStor5300F V5

V500R007 1

148

Page 149: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

19 iSCSI 2 Ports 100GbpsETH

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicFastLinQQL45611HLCU

8.37.6.0 mfw8.35.41.0storm 8.7.9.0

MPIO OceanStor5300F V5

V500R007 1

20 iSCSI 2 Ports 100GbpsETH

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicFastLinQQL45611HLCU

8.37.6.0 mfw8.35.41.0storm 8.7.9.0

MPIO OceanStor5300F V5

V500R007 1

1 The storage system version must be V500R007C30 or later.

2 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

149

Page 150: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

20 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLA2460

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

150

Page 151: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLA2462

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

151

Page 152: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2460

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

152

Page 153: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2462

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

153

Page 154: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

154

Page 155: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2560

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2,5

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2,5

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2,5

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2,5

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2560

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2,5

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2560

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 1,2,5

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,4

20 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,4

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

4 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

5 The storage system version must be V500R007C30 or later.

155

Page 156: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

156

Page 157: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

157

Page 158: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2562

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

9.1.15.1 8.01.02 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3,5

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3,5

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3,5

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3,5

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2562

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3,5

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2562

9.1.15.1 8.01.02 UltraPath OceanStor5300F V5

V500R007 2,3,5

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 2,3,4

14 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 2,3,4

15 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 2,3,4

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 2,3,4

17 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 2,3,4

18 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 2,3,4

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 2,3,4

20 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 2,3,4

1 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

2 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

3 Select Windows Server 2012 as the operating system of the host.

4 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

5 The storage system version must be V500R007C30 or later.

158

Page 159: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2,3

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

159

Page 160: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

1 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2670

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

17 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

19 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

20 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

160

Page 161: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

2 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

3 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

5 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

6 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

8 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

9 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

11 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

12 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

14 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

15 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

MPIO OceanStor5300F V5

V500R007 1,2,3

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

161

Page 162: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

3 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2672

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

UltraPath OceanStor5300F V5

V500R007

18 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

UltraPath OceanStor5300F V5

V500R007

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

UltraPath OceanStor5300F V5

V500R007

20 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

UltraPath OceanStor5300F V5

V500R007

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

UltraPath OceanStor5300F V5

V500R007

2 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

UltraPath OceanStor5300F V5

V500R007

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

UltraPath OceanStor5300F V5

V500R007

4 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

UltraPath OceanStor5300F V5

V500R007

162

Page 163: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2692

UltraPath OceanStor5300F V5

V500R007

6 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2692

UltraPath OceanStor5300F V5

V500R007

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

UltraPath OceanStor5300F V5

V500R007

8 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

UltraPath OceanStor5300F V5

V500R007

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

9.1.15.1 08.01.02 MPIO OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

9.1.15.1 08.01.02 MPIO OceanStor5300F V5

V500R007 1,2

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

9.1.15.1 08.01.02 MPIO OceanStor5300F V5

V500R007 1,2

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

9.1.15.1 08.01.02 MPIO OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2692

9.1.15.1 08.01.02 MPIO OceanStor5300F V5

V500R007 1,2

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

9.1.15.1 08.01.02 MPIO OceanStor5300F V5

V500R007 1,2

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

9.1.15.1 08.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

9.1.15.1 08.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

9.1.15.1 08.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

9.1.15.1 08.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2692

9.1.15.1 08.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2692

9.1.15.1 08.01.02 UltraPath OceanStor5300F V5

V500R007 1,2

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

163

Page 164: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2740

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

164

Page 165: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

9 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

12 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

9.1.15.1 8.03.04 MPIO OceanStor5300F V5

V500R007 2,3

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

9.1.15.1 8.03.04 MPIO OceanStor5300F V5

V500R007 2,3

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

9.1.15.1 8.03.04 MPIO OceanStor5300F V5

V500R007 2,3

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

9.1.15.1 8.03.04 MPIO OceanStor5300F V5

V500R007 2,3

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2742

9.1.15.1 8.03.04 MPIO OceanStor5300F V5

V500R007 2,3

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

9.1.15.1 8.03.04 MPIO OceanStor5300F V5

V500R007 2,3

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

9.1.15.1 8.03.04 UltraPath OceanStor5300F V5

V500R007 1,2,3

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

9.1.15.1 8.03.04 UltraPath OceanStor5300F V5

V500R007 1,2,3

165

Page 166: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

9.1.15.1 8.03.04 UltraPath OceanStor5300F V5

V500R007 1,2,3

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

9.1.15.1 8.03.04 UltraPath OceanStor5300F V5

V500R007 1,2,3

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2742

9.1.15.1 8.03.04 UltraPath OceanStor5300F V5

V500R007 1,2,3

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2742

9.1.15.1 8.03.04 UltraPath OceanStor5300F V5

V500R007 1,2,3

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

17 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

19 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

20 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

2 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

3 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

5 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

6 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

8 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

9 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

11 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

166

Page 167: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

12 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

14 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

15 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016

QLogicQLE2764

UltraPath OceanStor5300F V5

V500R007 1,2

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

DELLF641C

MPIO OceanStor5300F V5

V500R007 1,2,3,4

17 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

DELLF641C

MPIO OceanStor5300F V5

V500R007 1,2,3,4

18 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

DELLF641C

MPIO OceanStor5300F V5

V500R007 1,2,3,4

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

DELLH144C

MPIO OceanStor5300F V5

V500R007 1,2,3,4

20 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

DELLH144C

MPIO OceanStor5300F V5

V500R007 1,2,3,4

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

DELLH144C

MPIO OceanStor5300F V5

V500R007 1,2,3,4

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

DELLLPe12000-E

MPIO OceanStor5300F V5

V500R007 1,2,3,4

3 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

DELLLPe12000-E

MPIO OceanStor5300F V5

V500R007 1,2,3,4

4 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

DELLLPe12000-E

MPIO OceanStor5300F V5

V500R007 1,2,3,4

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

DELLLPe12000-E

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

167

Page 168: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

DELLLPe12002-E

MPIO OceanStor5300F V5

V500R007 1,2,3,4

7 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

DELLLPe12002-E

MPIO OceanStor5300F V5

V500R007 1,2,3,4

8 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

DELLLPe12002-E

MPIO OceanStor5300F V5

V500R007 1,2,3,4

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

DELLLPe12002-E

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

11 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

12 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

14 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

15 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

17 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

18 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

20 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

168

Page 169: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

5 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

6 The OS version of the VM is Windows Server 2012, Windows Server 2012 R2, or Windows Server 2016.

7 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

3 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

4 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

6 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

7 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

9 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

10 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

MPIO OceanStor5300F V5

V500R007 1,2,3,4

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

169

Page 170: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

14 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

15 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

16 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12000

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

18 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

19 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

5 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

6 The OS version of the VM is Windows Server 2012, Windows Server 2012 R2, or Windows Server 2016.

7 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

2 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

4 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

5 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

170

Page 171: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

7 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

8 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

10 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

11 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

13 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

14 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

16 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

17 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

MPIO OceanStor5300F V5

V500R007 1,2,3,4

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

20 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

171

Page 172: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

5 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

6 The OS version of the VM is Windows Server 2012, Windows Server 2012 R2, or Windows Server 2016.

7 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexLPe12002

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

4 FCoE 4 Ports SmartIO10Gbps FCoE

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 2,4,6

5 FCoE 4 Ports SmartIO10Gbps FCoE

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 2,4,6

6 FCoE 4 Ports SmartIO10Gbps FCoE

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 2,4,6

7 FCoE 4 Ports SmartIO10Gbps FCoE

Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 2,4,6

8 FCoE 4 Ports SmartIO10Gbps FCoE

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 2,4,6

9 FCoE 4 Ports SmartIO10Gbps FCoE

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 2,4,6

10 FCoE 4 Ports SmartIO10Gbps FCoE

Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexOCe11102-FM

UltraPath OceanStor5300F V5

V500R007 2,4,6

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexOCe14102-NM

MPIO OceanStor5300F V5

V500R007 2,4,5,6

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexOCe14102-NM

MPIO OceanStor5300F V5

V500R007 2,4,5,6

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexOCe14102-NM

MPIO OceanStor5300F V5

V500R007 2,4,5,6

172

Page 173: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexOCe14102-NM

MPIO OceanStor5300F V5

V500R007 2,4,5,6

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexOCe14102-NM

MPIO OceanStor5300F V5

V500R007 2,4,5,6

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

EmulexOCe14102-NM

MPIO OceanStor5300F V5

V500R007 2,4,5,6

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

EmulexOCe14102-NM

MPIO OceanStor5300F V5

V500R007 2,4,5,6

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

HP AJ762A MPIO OceanStor5300F V5

V500R007 2,4,5,6

19 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

HP AJ762A MPIO OceanStor5300F V5

V500R007 2,4,5,6

20 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

HP AJ762A MPIO OceanStor5300F V5

V500R007 2,4,5,6

1 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

2 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

3 The OS version of the VM is Windows Server 2012, Windows Server 2012 R2, or Windows Server 2016.

4 Select Windows Server 2012 as the operating system of the host.

5 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

6 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

7 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

HP AJ762A 11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

HP AJ763A MPIO OceanStor5300F V5

V500R007 2,4,5,6

3 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

HP AJ763A MPIO OceanStor5300F V5

V500R007 2,4,5,6

4 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

HP AJ763A MPIO OceanStor5300F V5

V500R007 2,4,5,6

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

HP AJ763A 11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

173

Page 174: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

HPAJ764A/82Q

MPIO OceanStor5300F V5

V500R007 2,4,5,6

7 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

HPAJ764A/82Q

MPIO OceanStor5300F V5

V500R007 2,4,5,6

8 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

HPAJ764A/82Q

MPIO OceanStor5300F V5

V500R007 2,4,5,6

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

HPAK344A/81Q

MPIO OceanStor5300F V5

V500R007 2,4,5,6

10 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

HPAK344A/81Q

MPIO OceanStor5300F V5

V500R007 2,4,5,6

11 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

HPAK344A/81Q

MPIO OceanStor5300F V5

V500R007 2,4,5,6

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0485

MPIO OceanStor5300F V5

V500R007 2,4,5,6

13 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0485

MPIO OceanStor5300F V5

V500R007 2,4,5,6

14 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0485

MPIO OceanStor5300F V5

V500R007 2,4,5,6

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0485

MPIO OceanStor5300F V5

V500R007 2,4,5,6

16 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0485

MPIO OceanStor5300F V5

V500R007 2,4,5,6

17 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0485

MPIO OceanStor5300F V5

V500R007 2,4,5,6

18 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0485

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

19 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0485

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0494

MPIO OceanStor5300F V5

V500R007 2,4,5,6

1 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

2 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

3 The OS version of the VM is Windows Server 2012, Windows Server 2012 R2, or Windows Server 2016.

4 Select Windows Server 2012 as the operating system of the host.

174

Page 175: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

5 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

6 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

7 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3,4

2 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3,4

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3,4

4 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3,4

5 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0494

MPIO OceanStor5300F V5

V500R007 1,2,3,4

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0494

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0494

11.4.204.8 2.01A10 MPIO OceanStor5300F V5

V500R007 1,2,3,4,5,6,7

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0501

MPIO OceanStor5300F V5

V500R007 1,2,3,4

9 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0501

MPIO OceanStor5300F V5

V500R007 1,2,3,4

10 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0501

MPIO OceanStor5300F V5

V500R007 1,2,3,4

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0501

MPIO OceanStor5300F V5

V500R007 1,2,3,4

12 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0501

MPIO OceanStor5300F V5

V500R007 1,2,3,4

13 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0501

MPIO OceanStor5300F V5

V500R007 1,2,3,4

175

Page 176: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2,3,4

15 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2,3,4

16 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2,3,4

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2,3,4

18 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2,3,4

19 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

IBM42D0510

MPIO OceanStor5300F V5

V500R007 1,2,3,4

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

5 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

6 The OS version of the VM is Windows Server 2012, Windows Server 2012 R2, or Windows Server 2016.

7 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

2 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

4 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

5 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

176

Page 177: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

7 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

8 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

10 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

11 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

13 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

14 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

16 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

17 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

19 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

20 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2560

MPIO OceanStor5300F V5

V500R007 1,2,3,4

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

177

Page 178: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

2 FC 8 Ports 16Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

3 FC 8 Ports 8Gbps FC DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

5 FC 8 Ports 16Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

6 FC 8 Ports 8Gbps FC FujitsuPrimergyRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

8 FC 8 Ports 16Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

9 FC 8 Ports 8Gbps FC HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

11 FC 8 Ports 16Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

12 FC 8 Ports 8Gbps FC Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

14 FC 8 Ports 16Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

178

Page 179: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

15 FC 8 Ports 8Gbps FC IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

17 FC 8 Ports 16Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

18 FC 8 Ports 8Gbps FC Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

20 FC 8 Ports 16Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 8 Ports 8Gbps FC Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2562

MPIO OceanStor5300F V5

V500R007 1,2,3,4

2 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2670

9.1.15.1 7.03.00 MPIO OceanStor5300F V5

V500R007 2,4,5

3 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2670

9.1.15.1 7.03.00 MPIO OceanStor5300F V5

V500R007 2,4,5

4 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2670

9.1.15.1 7.03.00 MPIO OceanStor5300F V5

V500R007 2,4,5

5 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2670

9.1.15.1 7.03.00 MPIO OceanStor5300F V5

V500R007 2,4,5

6 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2670

9.1.15.1 7.03.00 MPIO OceanStor5300F V5

V500R007 2,4,5

7 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2670

9.1.15.1 7.03.00 MPIO OceanStor5300F V5

V500R007 2,4,5

179

Page 180: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2672

9.1.15.1 7.03.00 MPIO OceanStor5300F V5

V500R007 2,4,5

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2672

9.1.15.1 7.03.00 MPIO OceanStor5300F V5

V500R007 2,4,5

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2672

9.1.15.1 7.03.00 MPIO OceanStor5300F V5

V500R007 2,4,5

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2672

9.1.15.1 7.03.00 MPIO OceanStor5300F V5

V500R007 2,4,5

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2672

9.1.15.1 7.03.00 MPIO OceanStor5300F V5

V500R007 2,4,5

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2016with Hyper-V

QLogicQLE2672

9.1.15.1 7.03.00 MPIO OceanStor5300F V5

V500R007 2,4,5

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2019

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 2

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2019

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 2

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2019

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 2

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2019

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 2

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2019

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 2

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2019

EmulexLPe16000

MPIO OceanStor5300F V5

V500R007 2

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2019

EmulexLPE16000B

MPIO OceanStor5300F V5

V500R007 2

1 Install the KB3213986 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4009938/windows-10-update-kb3213986.

2 Select Windows Server 2012 as the operating system of the host.

3 Install the KB4025334 patch in the operating system. For details, see https://support.microsoft.com/en-us/help/4025334/windows-10-update-kb3213986. You can obtain the patch from http://catalog.update.microsoft.com/v7/site/Search.aspx?q=KB4025334.

4 In a Windows Server cluster, if NPIV is enabled in Hyper-V and UltraPath is used in Guest OS, online VM migration is onlysupported when the UltraPath version is 21.2.0 or later.

5 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2019

EmulexLPE16000B

MPIO OceanStor5300F V5

V500R007 1

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2019

EmulexLPE16000B

MPIO OceanStor5300F V5

V500R007 1

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2019

EmulexLPE16000B

MPIO OceanStor5300F V5

V500R007 1

180

Page 181: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2019

EmulexLPE16000B

MPIO OceanStor5300F V5

V500R007 1

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2019

EmulexLPE16000B

MPIO OceanStor5300F V5

V500R007 1

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2019

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2019

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2019

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2019

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1

10 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2019

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1

11 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2019

EmulexLPe16002

MPIO OceanStor5300F V5

V500R007 1

12 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2019

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1

13 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2019

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1

14 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2019

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1

15 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2019

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1

16 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2019

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1

17 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2019

EmulexLPe16002B

MPIO OceanStor5300F V5

V500R007 1

18 FC 4 Ports SmartIO16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2019

EmulexLPE16004

MPIO OceanStor5300F V5

V500R007 1

19 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2019

EmulexLPE16004

MPIO OceanStor5300F V5

V500R007 1

20 FC 4 Ports SmartIO16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2019

EmulexLPE16004

MPIO OceanStor5300F V5

V500R007 1

1 Select Windows Server 2012 as the operating system of the host.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2019

EmulexLPE16004

MPIO OceanStor5300F V5

V500R007 1

2 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2019

EmulexLPE16004

MPIO OceanStor5300F V5

V500R007 1

3 FC 4 Ports SmartIO16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2019

EmulexLPE16004

MPIO OceanStor5300F V5

V500R007 1

4 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2019

HP QR558A MPIO OceanStor5300F V5

V500R007 1

5 FC 4 Ports SmartIO16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2019

HP QR559A MPIO OceanStor5300F V5

V500R007 1

181

Page 182: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

6 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2019

IBM81Y1655

MPIO OceanStor5300F V5

V500R007 1

7 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2019

IBM81Y1655

MPIO OceanStor5300F V5

V500R007 1

8 FC 4 Ports SmartIO16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2019

IBM81Y1662

MPIO OceanStor5300F V5

V500R007 1

9 FC 4 Ports SmartIO16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2019

IBM81Y1662

MPIO OceanStor5300F V5

V500R007 1

10 iSCSI 4 Ports SmartIO25Gbps ETH

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2019

IntelXXV710-DA2

1.8.103.2 5.510x80002bca1.1568.0

MPIO OceanStor5300F V5

V500R007 2

11 iSCSI 4 Ports SmartIO25Gbps ETH

HP ProLiantRack Servers

MicrosoftWindowsServer 2019

IntelXXV710-DA2

1.8.103.2 5.510x80002bca1.1568.0

MPIO OceanStor5300F V5

V500R007 2

12 iSCSI 4 Ports SmartIO25Gbps ETH

Huawei RHRack Servers

MicrosoftWindowsServer 2019

IntelXXV710-DA2

1.8.103.2 5.510x80002bca1.1568.0

MPIO OceanStor5300F V5

V500R007 2

13 iSCSI 4 Ports SmartIO25Gbps ETH

IBM xSeriesRack Servers

MicrosoftWindowsServer 2019

IntelXXV710-DA2

1.8.103.2 5.510x80002bca1.1568.0

MPIO OceanStor5300F V5

V500R007 2

14 iSCSI 4 Ports SmartIO25Gbps ETH

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2019

IntelXXV710-DA2

1.8.103.2 5.510x80002bca1.1568.0

MPIO OceanStor5300F V5

V500R007 2

15 iSCSI 4 Ports SmartIO25Gbps ETH

Oracle x86Servers

MicrosoftWindowsServer 2019

IntelXXV710-DA2

1.8.103.2 5.510x80002bca1.1568.0

MPIO OceanStor5300F V5

V500R007 2

16 iSCSI 2 Ports 100GbpsETH

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2019

MellanoxMCX416A-CCAT

1.90.19240.0 12.23.1020 MPIO OceanStor5300F V5

V500R007 2

17 iSCSI 2 Ports 100GbpsETH

HP ProLiantRack Servers

MicrosoftWindowsServer 2019

MellanoxMCX416A-CCAT

1.90.19240.0 12.23.1020 MPIO OceanStor5300F V5

V500R007 2

18 iSCSI 2 Ports 100GbpsETH

Huawei RHRack Servers

MicrosoftWindowsServer 2019

MellanoxMCX416A-CCAT

1.90.19240.0 12.23.1020 MPIO OceanStor5300F V5

V500R007 2

19 iSCSI 2 Ports 100GbpsETH

IBM xSeriesRack Servers

MicrosoftWindowsServer 2019

MellanoxMCX416A-CCAT

1.90.19240.0 12.23.1020 MPIO OceanStor5300F V5

V500R007 2

20 iSCSI 2 Ports 100GbpsETH

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2019

MellanoxMCX416A-CCAT

1.90.19240.0 12.23.1020 MPIO OceanStor5300F V5

V500R007 2

1 Select Windows Server 2012 as the operating system of the host.

2 The storage system version must be V500R007C30 or later.

No. Protocol

Array InterfaceCard Type

ServerModel

OperatingSystem

Host BusAdapter

HBA driverversion

HBAfirmwareversion

MultipathingSoftware

StorageSystem

StorageSystemVersion

Remarks

1 iSCSI 2 Ports 100GbpsETH

Oracle x86Servers

MicrosoftWindowsServer 2019

MellanoxMCX416A-CCAT

1.90.19240.0 12.23.1020 MPIO OceanStor5300F V5

V500R007 1

2 FC 4 Ports SmartIO16Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2019

QLogicQLE2692

9.1.15.1 8.08.05 MPIO OceanStor5300F V5

V500R007

3 FC 4 Ports SmartIO16Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2019

QLogicQLE2692

9.1.15.1 8.08.05 MPIO OceanStor5300F V5

V500R007

4 FC 4 Ports SmartIO16Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2019

QLogicQLE2692

9.1.15.1 8.08.05 MPIO OceanStor5300F V5

V500R007

5 FC 4 Ports SmartIO16Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2019

QLogicQLE2692

9.1.15.1 8.08.05 MPIO OceanStor5300F V5

V500R007

6 FC 4 Ports SmartIO16Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2019

QLogicQLE2692

9.1.15.1 8.08.05 MPIO OceanStor5300F V5

V500R007

7 FC 4 Ports SmartIO16Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2019

QLogicQLE2692

9.1.15.1 8.08.05 MPIO OceanStor5300F V5

V500R007

182

Page 183: Huawei OceanStor 5300F V5 Converged Storage Interoperability … · 2019-09-13 · Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service

8 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

DellPowerEdgeRack Servers

MicrosoftWindowsServer 2019with Hyper-V

QLogicQLE2692

9.1.15.1 8.03.04 MPIO OceanStor5300F V5

V500R007C30

1,2,3,4

9 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

HP ProLiantRack Servers

MicrosoftWindowsServer 2019with Hyper-V

QLogicQLE2692

9.1.15.1 8.03.04 MPIO OceanStor5300F V5

V500R007C30

1,2,3,4

10 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Huawei RHRack Servers

MicrosoftWindowsServer 2019with Hyper-V

QLogicQLE2692

9.1.15.1 8.03.04 MPIO OceanStor5300F V5

V500R007C30

1,2,3,4

11 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

IBM xSeriesRack Servers

MicrosoftWindowsServer 2019with Hyper-V

QLogicQLE2692

9.1.15.1 8.03.04 MPIO OceanStor5300F V5

V500R007C30

1,2,3,4

12 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Lenovo FlexSystemxSeries

MicrosoftWindowsServer 2019with Hyper-V

QLogicQLE2692

9.1.15.1 8.03.04 MPIO OceanStor5300F V5

V500R007C30

1,2,3,4

13 FC 4 Ports SmartIO32Gbps/16Gbps/8Gbps FC

Oracle x86Servers

MicrosoftWindowsServer 2019with Hyper-V

QLogicQLE2692

9.1.15.1 8.03.04 MPIO OceanStor5300F V5

V500R007C30

1,2,3,4

1 The storage system version must be V500R007C30 or later.

2 If a LUN has been mapped to the host, you must restart the host for the configuration to take effect after you change theinitiator parameter settings. If it is the first mapping, restart is not needed.

3 The OS version of the VM is Windows Server 2012, Windows Server 2012 R2, or Windows Server 2016.

4 Select Windows Server 2012 as the operating system of the host.

183