6
Digital care communication system for hospitals and nursing homes

Document

Embed Size (px)

DESCRIPTION

http://www.bizflips.com/library/pdf/Ackermann/clino/clino_phon_21.pdf

Citation preview

Page 1: Document

Digi ta l care communicat ion system for hospi ta ls

and nurs ing homes

Page 2: Document

Easy handling, maximum comfort.

clino phon 21 opens new paths for care

communication within hospitals and nurs-

ing homes setting standards for nurse

call, patient-nurse communication and

audio transmission, as well as TV and

radio control. User-friendly terminals and

components add value to staff and

patients by their excellent and outstanding

functionality and design. Specifically for

centralized care concepts, clino phon 21

offers first class digital communication,

discreet and hands-free between the staff

and patients. Using standard components

and terminals the system can be extended

to the multimedia communication system

dlino com 21. Using the same general

infrastructure and control units clino phon

21 offers a simple upgrade route for the

service integrating clino com 21.

Page 3: Document

The interface bedside –

the bed electronic

P Call button for the nurse call

P Cancel button, offering the optional

opportunity of cancelling the pending

call from bedside individually

P Autorelease socket for the

connection of the patient handset or

pear / multiple push buttons

P Loudspeaker and microphone for

digital handsfree individual speech

per bed, in the case that a pear or

multiple push button is used –

the perfect solution not only within

centralized systems.

P 7-pole socket for the connection of

alternatively:

P parallel pear or multiple

push buttons

P noise sensors

P pneumatic call units e.g. for people

affected in their mobility.

P 6-pole socket with galvanic

separation according to EN 60950 for

the connection of medical devices

such as infusion pumps etc.

Page 4: Document

A large variety of system interfaces inte-

grate the care communication system

clino phon 21 in the communication infra-

structure of its installation environment. In

particular the cost for separate radio dis-

tribution can be saved because the cab-

ling of clino phon 21 already supports the

distribution of up to 16 radio channels. The

central radio source is fed into an audio

interface of a data management processor

and is converted into high-quality digital

radio signals for a high-class transmission.

The data management processor is the

central interface to the nurse call server

and at the same time represents the cen-

tral control unit for up to 2 wards.

Together with the standard connection

options of paging and DECT systems for

the alarming of the medical or technical

System overv iew cl ino phon 21

Backbone

Room bus

Room bus

Ethernet EDP

Fire Detection

Paging / DECT

Nurse call server

Ward bus

service, other security relevant systems

such as fire detection or intrusion alarm

systems can be connected to clino phon 21.

Of course, call logging and call evaluation,

the graphical call indication on a central or

local ward PC are part of the standard

functionality of this comprehensive com-

munication system for professional care.

System overview

P Hierarchic network structure

(room bus, ward bus, backbone)

P Loop structure of the bus systems

(permanent function control of the

components)

P Small distances between the devices

allow plastic fibre cable (POF-cable)

for time saving installation

P Standardized system interfaces

(easy connection of non-propietary

systems such as IT, paging, DECT,

BMS....)

P Extensive network management tools

(remote control, performant mainten-

ance and analysis tools)

Page 5: Document

Especially adapted to the requirements

of the patients – The patient handset

clino phon 21:

P Big ergonomic call button with

reassurance lamp and finding light

P Clear structured function buttons –

2 light control buttons (yellow),

-one menu button to select the

function TV or radio control,

2 buttons for the channel search,

2 buttons for the loudness control,

1 on/off button

P Bipartite display for the indication of

the actual TV or Radio channel,

in off-status indication of the time

P Loudspeaker and microphone for the

discreet conversation between

patient and staff

P Socket for headphone connection

P Shock protection by a surrounding

plastic frame and spash-proof (IP 54)

to meet the special requirements

of care environments

P Auto-release plug for the protection

of the connection cable in case of high

pulling force

Page 6: Document

21.1

3GB

/040

3/30

00/f

G

Prin

ted

in G

erm

any

To

the

best

of o

ur k

now

ledg

e, o

ur p

ublic

atio

ns a

re c

orre

ct, b

ut th

is d

oes

not r

ende

r the

m le

gally

bin

ding

. All r

ight

s re

serv

ed. R

epro

duct

ion

– in

par

t or i

n w

hole

– o

nly

with

writ

ten

perm

issi

on. W

e re

serv

e th

e rig

ht to

mak

e ch

ange

s in

line

with

tech

nica

l pro

gres

s.

Albert Ackermann GmbH + Co. KGAlbertstraße 4–8 · D-51643 Gummersbach

Telephone +49 22 61 83 361 · Fax +49 22 61 83 576www.ackermann.com

e-mail: [email protected]