Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
Hydraulic Megastore Holmbury Inc: [email protected] | +1 (866) 465-6287
FLAT
FAC
E CO
UPL
ING
S
HQ & H SERIESFlat face couplings made to the ISO 16028 Standard
INTRODUCTIONThe HQ and H Series flat face couplings are Holmbury’s flagship products, known globally for their leak free performance in high pressure pulse, hammer circuits and many other applications. Preferred choice for many global OEMs.
CONSTRUCTION• HQ Series (Sizes 06 to 25)- Carbon steel with zinc nickel
plating (1200 hours with no red rust in salt spray tests)• H Series (Sizes 32 to 40)- Carbon steel with trivalent plating• Fitted with Nitrile seals (Viton seals available)• Also available in AISI 316 stainless steel (See HSS Series)
FEATURES• Safety locking sleeve fitted as standard to prevent
accidental disconnection• Flat faces are easily wiped clean• Allows for minimal inclusion of air and contaminents
during connection• Flat face design prevents fluid loss during disconnection• Bidirectional flow
ACCESSORIES• Dust Caps, Plugs and Parking Stations are available for the
HQ Series
SPECIFICATIONS• Operating temperatures (With Nitrile seals): -40°C (-40°F)
to 106°C (223°F), (With Viton seals): -20°C (-4°F) to 200°C(392°F)
• Couplings have been tested to the ISO 7241-2 Standard
APPLICATIONS• Hammer circuits• High pressure pulse applications• Leak free environments• Construction plant, mobile equipment, general industrial,
nuclear, mining and agricultural industries
ORDER CODES
Body Size
Series
N = NPT
06 |10 | 12 | 16 | 19 | 25 | 32 | 40Thread Size
08 - ½” F = Female
M = Male24 - 1½” 20 - 1¼”
G = BSPP
04 - ¼”
06 - / ”
12 - ¾”M = Metric
16 - 1”
32 - 2”
Thread Type
HQ 19 M 16 G
S = SAEFS = ORFSR = BSPT
Blank = FemaleThread Gender
M = MaleHQ | H
Gender
J = JIC
--
Holmbury Ltd: [email protected] | +44 (0) 1732 378912 Hydraulic Megastore
Size Thread Size (A) B C D ØE F G ØH ØI ØJ
Maximum Working Pressure
Burst Pressure (Coupled)
Burst Pressure
(Male)
Burst Pressure (Female)
Dimensions in mm Bar
Dimensions in Inches Psi
HQ 06 1/4”22.0 27.0 53.8 28.0 54.3 97.0 24.0 29.0 16.2 400 1700 1220 1500
0.9 1.1 2.1 1.1 2.1 3.8 0.9 1.1 0.6 5800 24650 17690 21750
HQ 10 3/8”27.0 30.0 60.2 31.8 69.3 113.3 29.0 32.0 19.7 350 1500 1050 1100
1.1 1.2 2.4 1.3 2.7 4.5 1.1 1.3 0.8 5075 21750 15225 15950
HQ 10 1/2”27.0 30.0 63.2 31.8 74.2 121.5 29.0 32.0 19.7 350 1500 1050 1100
1.1 1.2 2.5 1.3 2.9 4.8 1.1 1.3 0.8 5075 21750 15225 15950
HQ 12 1/2”& 3/4”36.0 36.0 71.2 37.8 83.7 137.7 40.0 40.0 24.5 350 1200 1000 1050
1.4 1.4 2.8 1.5 3.3 5.4 1.6 1.6 1.0 5075 17400 14500 15225
HQ 16 3/4”36.0 41.0 73.1 42.0 83.9 139.8 38.5 45.1 27.0 350 1200 1100 1100
1.4 1.6 2.9 1.7 3.3 5.5 1.5 1.8 1.1 5075 17400 15950 15950
HQ 19 1”46.0 46.0 84.0 45.5 99.0 161.6 50.3 50.2 30.0 350 1450 1050 1050
1.8 1.8 3.3 1.8 3.9 6.4 2.0 2.0 1.2 5075 21025 15225 15225
HQ 25 1 1/4”55.0 55.0 90.4 55.0 106.2 173.3 59.7 59.7 36.0 260 800 800 800
2.2 2.2 3.6 2.2 4.2 6.8 2.4 2.4 1.4 3770 11600 11600 11600
H 32 1 1/2”70.0 70.0 119.8 79.0 118.5 209.5 77.0 79.0 57.0 250 1100 1200 1200
2.8 2.8 4.7 3.1 4.7 8.2 3.0 3.1 2.2 3625 15950 17400 17400
H 40 2”80.0 80.0 173.4 103.0 145.5 282.3 106.2 106.2 72.9 250 1000 1000 1000
3.1 3.1 6.8 4.1 5.7 11.1 4.2 4.2 2.9 3625 14500 14500 14500