Data sheet Key features • L2/L3 VXLAN and EVPN support for virtualized environments • OpenFlow support for investment protection and SDN environments • High-density 10GbE, 40GbE with 40 G or 100 G uplink for spine and leaf deployments • Unify management of virtual and physical network with VEPA and IMC • HPE FlexFabric Network Analytics solution capability for real time microburst detection Product overview The HPE FlexFabric 5940 Switch Series is a family of high-performance and low- latency 10GbE, 40GbE top-of-rack (ToR) data center switches. The switch series also includes 100 G and 40 G uplink technology and is part of the HPE FlexFabric data center solution, which is a cornerstone of the FlexNetwork architecture. The FlexFabric 5940 Switch Series is ideally suited for deployment at the aggregation or server access layer of large enterprise data centers, or at the core layer of medium-sized enterprises. With the increased pace of deploying virtualized applications, adopting software-defined networking, and the server-to-server traffic, many data centers now require spine and ToR switch innovations that will meet their requirements. The HPE FlexFabric 5940 is optimized to meet the increasing requirements for higher-performance server connectivity, convergence of Ethernet and storage traffic, the capability to handle virtual environments, and low latency. Features and benefits Quality of Service (QoS) • Powerful QoS features Flexible queue scheduling Including strict priority (SP), WRR, WDRR, WFQ, SP+WRR, SP+WDRR, SP+WFQ, configurable buffer, time range, queue shaping, CAR with 8 Kbps granularity HPE FlexFabric 5940 Switch Series

HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

  • Upload
    dinhthu

  • View
    220

  • Download
    2

Embed Size (px)

Citation preview

Page 1: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Data sheet

Key features

•L2/L3VXLANandEVPNsupportforvirtualizedenvironments

•OpenFlowsupportforinvestmentprotectionandSDNenvironments

•High-density10GbE,40GbEwith40Gor100Guplinkforspineandleafdeployments

•UnifymanagementofvirtualandphysicalnetworkwithVEPAandIMC

•HPEFlexFabricNetworkAnalyticssolutioncapabilityforrealtimemicroburstdetection

Product overview

TheHPEFlexFabric5940SwitchSeriesisafamilyofhigh-performanceandlow-latency10GbE,40GbEtop-of-rack(ToR)datacenterswitches.Theswitchseriesalsoincludes100Gand40GuplinktechnologyandispartoftheHPEFlexFabricdata center solution,whichisacornerstoneoftheFlexNetworkarchitecture.

TheFlexFabric5940SwitchSeriesisideallysuitedfordeploymentattheaggregationorserveraccesslayeroflargeenterprisedatacenters,oratthecorelayerofmedium-sizedenterprises.

Withtheincreasedpaceofdeployingvirtualizedapplications,adoptingsoftware-definednetworking,andtheserver-to-servertraffic,manydatacentersnowrequirespineandToRswitchinnovationsthatwillmeettheirrequirements.TheHPEFlexFabric5940isoptimizedtomeettheincreasingrequirementsforhigher-performanceserverconnectivity,convergenceofEthernetandstoragetraffic,thecapabilitytohandlevirtualenvironments,andlowlatency.

Features and benefits

Quality of Service (QoS)•PowerfulQoSfeatures

–Flexible queue schedulingIncludingstrictpriority(SP),WRR,WDRR,WFQ,SP+WRR,SP+WDRR,SP+WFQ,configurablebuffer,timerange,queueshaping,CARwith8Kbpsgranularity

HPE FlexFabric 5940 Switch Series

Page 2: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 2Data sheet

–Packet filtering and remarkingPacketfilteringatL2throughL4;flowclassificationbasedonsourceMACaddress,destinationMACaddress,sourceIP(IPv4/IPv6)address,destinationIP(IPv4/IPv6)address,port,protocol,andVLAN

Data center optimized•Flexible high-port density

The5940SwitchSeriesenablescustomerstoscaletheirserver-edge10/40/100GbEToRdeploymentstonewheightswithhigh-density48fixedx10GbEwith6portsof40G;48fixedx10GbEwith6portsof100G;and32fixedx40GbE,alldeliveredina1RUdesign.The594032portsof40Gswitchcanalsobeconfiguredasa96x10GbEportdevicebyusinga40Gto10GbEsplittercablethatcanturn24ofthe40GbEportsintofour10GbEports.The48-portmodelscomeinSFP+orBASE-T.

The5940SwitchSeriesalsoincludes2-slot(1RU)and4-slot(2RU)optionswhichallowforcustomizationofportsattheToR.Moduleoptionsinclude8x40Gports;2x40Gand2x100Gports;24x10G(SFP+orBASE-T)with2x40Gports(MACsecandFCoptionsavailable).

•High-performance switchingCut-throughandnon-blockingarchitecturedeliverslowlatency(~1microsecondfor10GbE)forverydemandingenterpriseapplications;theswitchdelivershigh-performanceswitchingcapacityandwire-speedpacketforwarding

•Higher scalabilityHPEIntelligentResilientFabric(IRF)technologysimplifiesthearchitectureofserveraccessnetworks;uptonineHPE5940switchescanbecombinedtodeliverunmatchedscalabilityofvirtualizedaccesslayerswitchesandflattertwo-tiernetworksusingIRF,whichreducescostandcomplexity

•Advanced modular operating systemComwarev7software’smodulardesignandmultipleprocessesbringnativehighstability,independentprocessmonitoring,andrestart;theOSalsoallowsindividualsoftwaremodulestobeupgradedforhigheravailabilityandsupportsenhancedserviceabilityfunctionssuchashitlesssoftwareupgrades

•Reversible airflowEnhancedfordatacenterhot-coldaisledeploymentwithreversibleairflow—foreitherfront-to-backorback-to-frontairflow

•Redundant fans and power suppliesInternalredundantandhot-pluggablepowersuppliesanddualfantraysenhancereliabilityandavailability

•Lower OPEX and greener data centerProvidereversibleairflowandadvancedchassispowermanagement

•Jumbo framesWithframesizesofupto10,000bytesonGigabitEthernetand10-Gigabitports,allowshigh-performanceremotebackupanddisasterrecoveryservicestobeenabled

•VXLAN hardware supportVXLANL2andL3gatewaysupportforupto4Ktunnels

•Dynamic VXLAN configurationOVSDBandML2supportfordynamicVXLANconfiguration

•EVPNControlplaneprotocolforVXLANbasedonindustrystandards.ItenablesL2andL3control-planelearningofend-hostreachabilityinformation,enablingorganizationstoscaletheirVXLANinfrastructurebetter.IntegrationwithOpenStack®Neutronplug-inforoverlayautomationororchestration

Manageability•TheHPEFlexFabricNetworkAnalytics

solutionwithreal-timetelemetryanalysisprovidesinsightintodatacenternetworkoperation

–Tracksalltheaccountingassociatedwiththeadmissionandallocationprocessofallthebuffersandqueuesacrosstheingressandegressports

–Microburstcongestiondetection

–Richcongestionanalytics

–Buffercongestionstateandstatistics

–Formoreinformation,seetheHPE FlexFabric Network Analytics data sheetandHPE FlexFabric Network Analytics white paper.

•Full-featured consoleProvidescompletecontroloftheswitchwithafamiliarCLI

Page 3: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 3Data sheet

•Troubleshooting

– Ingressandegressportmonitoringenablenetworkproblemsolving

–TracerouteandpingEnabletestingofnetworkconnectivity

•Multiple configuration filesAllowsmultipleconfigurationfilestobestoredtoaflashimage

•SNMPv1, v2c, and v3Facilitatescentralizeddiscovery,monitoring,andsecuremanagementofnetworkingdevices

•Out-of-band interfaceIsolatesmanagementtrafficfromuserdataplanetrafficforcompleteisolationandtotalreachability,nomatterwhathappensinthedataplane

•Remote configuration and management Deliveredthroughasecurecommand-lineinterface(CLI)overTelnetandSSH;role-basedaccesscontrol(RBAC)providesmultiplelevelsofaccess;configurationrollbackandmultipleconfigurationsontheflashprovideeaseofoperation;remotevisibilityisprovidedwithsFlow®andSNMPv1,v2,orv3,andisfullysupportedinHPEIntelligentManagementCenter(IMC)

•ISSU and hot patching InServicesSoftwareUpgrade(ISSU)providessoftwareupgradesandhitlesspatchingofthemodularoperatingsystem

•Auto-configuration ProvidesautomaticconfigurationviaDHCPauto-configuration

•NTP, SNTPSynchronizestimekeepingamongdistributedtimeserversandclients;supportfornetworktimeprotocol(NTP),securenetworktimeprotocol(SNTP)

Resiliency and high availability•IRF technology

EnablesanHPEFlexFabrictodeliverresilient,scalable,andsecureddatacenternetworksforphysicalandvirtualizedenvironments;groupsuptonineHPE5940switchesinanIRFconfiguration,allowingthemtobeconfiguredandmanagedasasingleswitchwithasingleIPaddress;simplifiesToRdeploymentandmanagement,reducingdatacenterdeploymentandoperatingexpenses

•IEEE 802.1w Rapid Convergence Spanning Tree ProtocolIncreasesnetworkuptimethroughfasterrecoveryfromfailedlinks

•IEEE 802.1s Multiple Spanning TreeProvideshighlinkavailabilityinmultipleVLANenvironmentsbyallowingmultiplespanningtrees

•Virtual Router Redundancy Protocol (VRRP)Allowsgroupsoftworouterstobackeachotherupdynamicallytocreatehighlyavailableroutedenvironments

•Hitless patch upgradesAllowspatchesandnewservicefeaturestobeinstalledwithoutrestartingtheequipment,increasingnetworkuptimeandfacilitatingmaintenance

•Ultrafast protocol convergence (< 50 ms) with standard-based failure detectionBidirectionalForwardingDetection(BFD)enableslinkconnectivitymonitoringandreducesnetworkconvergencetimeforRIP,OSPF,BGP,IS-IS,VRRPandIRF

•Device Link Detection Protocol (DLDP)Monitorslinkconnectivityandshutsdownportsatbothendsifunidirectionaltrafficisdetected,preventingloopsinSTP-basednetworks

•Graceful restartAllowsrouterstoindicatetootherstheircapabilitytomaintainaroutingtableduringatemporaryshutdownandsignificantlyreducesconvergencetimesuponrecovery;supportsOSPF,BGP,andIS-IS

Layer 2 switching•MAC-based VLAN

Providesgranularcontrolandsecurity;usesRADIUStomapaMACaddress/usertospecificVLANs

•Address Resolution Protocol (ARP)Supportsstatic,dynamic,andreverseARPandARPproxy

•IEEE 802.3x Flow ControlProvidesintelligentcongestionmanagementviaPAUSEframes

•Ethernet Link AggregationProvidesIEEE802.3adLinkAggregationofupto16portspergroupandupto128groups;supportforLACP,LACPLocalForwardingFirst,andLACPshorttimeprovidesafast,resilientenvironmentthatisidealforthedatacenter

Page 4: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 4Data sheet

•Spanning Tree Protocol (STP)SupportsSTP(IEEE802.1D),RapidSTP(RSTP,IEEE802.1w),andMultipleSTP(MSTP,IEEE802.1s)

•VLAN support Providessupportfor4,094VLANsbasedonport,MACaddress,IPv4subnet,protocol,andguestVLAN;supportsVLANmapping

•IGMP supportProvidessupportforIGMPSnooping,Fast-Leave,andGroup-Policy;IPv6IGMPSnoopingprovidesL2optimizationofmulticasttraffic

•DHCP supportProvidesfullDHCPSnoopingsupportforDHCPSnoopingOption82,DHCPRelayOption82,DHCPSnoopingtrust,andDHCPSnoopingitembackup

L3 services•Address Resolution Protocol

DeterminestheMACaddressofanotherIPhostinthesamesubnet;supportsstaticARPs;gratuitousARPallowsdetectionofduplicateIPaddresses;proxyARPallowsnormalARPoperationbetweensubnetsorwhensubnetsareseparatedbyaL2network

•Dynamic Host Configuration Protocol (DHCP)SimplifiesthemanagementoflargeIPnetworksandsupportsclientandserver;DHCPRelayenablesDHCPoperationacrosssubnets

•Operations, administration, and maintenance (OAM) supportProvidessupportforConnectivityFaultManagement(IEEE802.1ag)andEthernetintheFirstMile(IEEE802.3ah);providesadditionalmonitoringthatcanbeusedforfastfaultdetectionandrecovery

L3 routing•VRRP and VRRP Extended

Allowsquickfailoverofrouterports

•Policy-based routingMakesroutingdecisionsbasedonpoliciessetbythenetworkadministrator

•Equal-Cost Multipath (ECMP) Enablesmultipleequal-costlinksinaroutingenvironmenttoincreaselinkredundancyandscalebandwidth

•L3 IPv4 routingProvidesroutingofIPv4atmediaspeed;supportsstaticroutes,RIPandRIPv2,OSPF,BGP,andIS-IS

•Open shortest path first (OSPF)Deliversfasterconvergence;usesthislink-stateroutingInteriorGatewayProtocol(IGP),whichsupportsECMP,NSSA,andMD5authenticationforincreasedsecurityandgracefulrestartforfasterfailurerecovery

•Border Gateway Protocol 4 (BGP-4) DeliversanimplementationoftheExteriorGatewayProtocol(EGP)utilizingpathvectors;usesTCPforenhancedreliabilityfortheroutediscoveryprocess;reducesbandwidthconsumptionbyadvertisingonlyincrementalupdates;supportsextensivepoliciesforincreasedflexibility;scalestoverylargenetworks

•Intermediate system to intermediate system (IS-IS)UsesapathvectorIGP,whichisdefinedbytheISOorganizationforIS-ISroutingandextendedbyIETFRFC1195tooperateinbothTCP/IPandtheOSIreferencemodel(IntegratedIS-IS)

•Static IPv6 routingProvidessimplemanuallyconfiguredIPv6routing

•Dual IP stackMaintainsseparatestacksforIPv4andIPv6toeasethetransitionfromanIPv4-onlynetworktoanIPv6-onlynetworkdesign

•Routing Information Protocol next generation (RIPng)ExtendsRIPv2tosupportIPv6addressing

•OSPFv3ProvidesOSPFsupportforIPv6

•BGP+ExtendsBGP-4tosupportMultiprotocolBGP(MBGP),includingsupportforIPv6addressing

•IS-IS for IPv6ExtendsIS-IStosupportIPv6addressing

•IPv6 tunnelingAllowsIPv6packetstotraverseIPv4-onlynetworksbyencapsulatingtheIPv6packetintoastandardIPv4packet;supportsmanuallyconfigured,6to4,andIntra-SiteAutomaticTunnelAddressingProtocol(ISATAP)tunnels;isanimportantelementforthetransitionfromIPv4toIPv6

Page 5: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 5Data sheet

•Policy routing Allowscustomfiltersforincreasedperformanceandsecurity;supportsACLs,IPprefix,ASpaths,communitylists,andaggregatepolicies

•Bidirectional Forwarding Detection (BFD)EnableslinkconnectivitymonitoringandreducesnetworkconvergencetimeforRIP,OSPF,BGP,IS-IS,VRRPandIRF

•Multicast Routing PIM Dense and Sparse Modes Providesrobustsupportofmulticastprotocols

•L3 IPv6 routingProvidesroutingofIPv6atmediaspeed;supportsstaticrouting,RIPng,OSPFv3,BGP-4+forIPv6,andIS-ISv6

Additional information•Green IT and power

Improvesenergyefficiencythroughtheuseofthelatestadvancesinsilicondevelopment;shutsoffunusedports,andutilizesvariablespeedfans,reducingenergycosts

Management•USB support

–File copyAllowsuserstocopyswitchfilestoandfromaUSBflashdrive

•Port mirroringEnablestrafficonaporttobesimultaneouslysenttoanetworkanalyzerformonitoring

•RemoteconfigurationandmanagementIsavailablethroughaCLI

•IEEE 802.1AB Link Layer Discovery Protocol (LLDP)Advertisesandreceivesmanagementinformationfromadjacentdevicesonanetwork,facilitatingeasymappingbynetworkmanagementapplications

•sFlow (RFC 3176)ProvidesscalableASIC-basedwirespeednetworkmonitoringandaccountingwithnoimpactonnetworkperformance;thisallowsnetworkoperatorstogatheravarietyofsophisticatednetworkstatisticsandinformationforcapacityplanningandreal-timenetworkmonitoringpurposes

•Command authorizationLeveragesRADIUStolinkacustomlistofCLIcommandstoanindividualnetworkadministrator’slogin;anaudittraildocumentsactivity

•Dual flash imagesProvidesindependentprimaryandsecondaryoperatingsystemfilesforbackupwhileupgrading

•Command-line interfaceProvidesasecure,easy-to-useCLIforconfiguringthemoduleviaSSHoraswitchconsole;providesdirectreal-timesessionvisibility

•LoggingProvideslocalandremoteloggingofeventsviaSNMP(v2candv3)andsyslog;provideslogthrottlingandlogfilteringtoreducethenumberoflogeventsgenerated

•Management interface control Providesmanagementaccessthroughamodemportandterminalinterface,aswellasin-bandandout-of-bandEthernetports;providesaccessthroughterminalinterface,Telnet,orSSH

•Industry-standard CLI with a hierarchical structureReducestrainingtimeandexpenses,andincreasesproductivityinmultivendorinstallations

•Management securityRestrictsaccesstocriticalconfigurationcommands;offersmultipleprivilegelevelswithpasswordprotection;ACLsprovideTelnetandSNMPaccess;localandremotesyslogcapabilitiesallowloggingofallaccess

•Information centerProvidesacentralrepositoryforsystemandnetworkinformation;aggregatesalllogs,traps,anddebugginginformationgeneratedbythesystemandmaintainstheminorderofseverity;outputsthenetworkinformationtomultiplechannelsbasedonuser-definedrules

•Network managementHPE IMCcentrallyconfigures,updates,monitors,andtroubleshoots

•Remote intelligent mirroringMirrorsingress/egressACL-selectedtrafficfromaswitchportorVLANtoalocalorremoteswitchportanywhereonthenetwork

Page 6: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 6Data sheet

Security•Access control lists (ACLs)

ProvideIPL3filteringbasedonsourceordestinationIPaddressorsubnetandsourceordestinationTCP/UDPportnumber

•RADIUS/TACACS+Easesswitchmanagementsecurityadministrationbyusingapasswordauthenticationserver

•Secure ShellEncryptsalltransmitteddataforsecureremoteCLIaccessoverIPnetworks

•IEEE 802.1X and RADIUS network loginsControlsport-basedaccessforauthenticationandaccountability

•Port securityAllowsaccessonlytospecifiedMACaddresses,whichcanbelearnedorspecifiedbytheadministrator

Convergence•LLDP Media Endpoint Discovery

DefinesastandardextensionofLLDPthatstoresvaluesforparameterssuchasQoSandVLANtoconfigurenetworkdevicesautomaticallysuchasIPphones

Warranty and support•1-year warranty

Seehpe.com/networking/warrantysummaryforwarrantyandsupportinformationincludedwithyourproductpurchase.

•Software releases Tofindsoftwareforyourproduct,refertohpe.com/networking/support;fordetailsonthesoftwarereleasesavailablewithyourproductpurchase,refertohpe.com/networking/warrantysummary.

Page 7: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 7Data sheet

HPE FlexFabric 5940 48SFP+ 6QSFP+ Switch (JH395A)

HPE FlexFabric 5940 32QSFP+ Switch (JH396A)

HPE FlexFabric 5940 48XGT 6QSFP+ Switch (JH394A)

I/O ports and slots 48fixed1000/10000SFP+ports6QSFP+40GbEports

32QSFP+40GbEports 48 1/10GBASE-Tports6QSFP+40GbEports

Additional ports and slots 1RJ-45and1MiniUSB2.0serialconsoleport1RJ-45out-of-bandmanagementport1USB2.0

1RJ-45and1MiniUSB2.0serialconsoleport1RJ-45out-of-bandmanagementport1USB2.0

1RJ-45and1MiniUSB2.0serialconsoleport1RJ-45out-of-bandmanagementport1USB2.0

Power supplies 2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

Fan tray 2fantrayslotsThecustomermustorderfantrays,asfantraysarenotincludedwiththeswitch.Thissystemrequirestwosame-directionairflowfantraystofunctionproperly.Thesystemshouldnotbeoperatedwithonlyonefantrayformorethan24hours.Thesystemshouldnotbeoperatedwithoutafantrayformorethantwominutes.Thesystemshouldnotbeoperatedoutsideofthetemperaturerangeof32°F(0°C)to113°F(45°C).Failuretocomplywiththeseoperatingrequirementsmayvoidtheproductwarranty.

2fantrayslotsThecustomermustorderfantrays,asfantraysarenotincludedwiththeswitch.Thissystemrequirestwosame-directionairflowfantraystofunctionproperly.Thesystemshouldnotbeoperatedwithonlyonefantrayformorethan24hours.Thesystemshouldnotbeoperatedwithoutafantrayformorethantwominutes.Thesystemshouldnotbeoperatedoutsideofthetemperaturerangeof32°F(0°C)to113°F(45°C).Failuretocomplywiththeseoperatingrequirementsmayvoidtheproductwarranty.

2fantrayslotsThecustomermustorderfantrays,asfantraysarenotincludedwiththeswitch.Thissystemrequirestwosame-directionairflowfantraystofunctionproperly.Thesystemshouldnotbeoperatedwithonlyonefantrayformorethan24hours.Thesystemshouldnotbeoperatedwithoutafantrayformorethantwominutes.Thesystemshouldnotbeoperatedoutsideofthetemperaturerangeof32°F(0°C)to113°F(45°C).Failuretocomplywiththeseoperatingrequirementsmayvoidtheproductwarranty.

Physical characteristicsDimensions

Weight

17.32(w)x18.11(d)x1.72(h)in.(44x46x4.36cm)22.05lb(10kg)shippingweight

17.32(w)x25.98(d)x1.74(h)in.(44x66x4.42cm)35.27lb(16kg)shippingweight

17.32(w)x25.98(d)x1.72(h)in.(44x66x4.36cm)28.66lb(13kg)shippingweight

Memory and processor 512MBflash;Packetbuffersize:16MB,2GBSDRAM

1GBflash;Packetbuffersize:16MB,4GBSDRAM

512MBflash;Packetbuffersize:16MB,2GBSDRAM

Performance10GbpsLatencyThroughputRouting/SwitchingcapacityRoutingtablesizeMACaddresstablesize

<1µs(64-bytepackets)Upto1071Mpps1440Gbps250Kentries(IPv4),64Kentries(IPv6)288Kentries

<1µs(64-bytepackets)Upto1904Mpps2560Gbps250Kentries(IPv4),64Kentries(IPv6)288Kentries

<1µs(64-bytepackets)Upto1071Mpps1440Gbps250Kentries(IPv4),64Kentries(IPv6)288Kentries

EnvironmentOperatingtemperatureOperatingrelativehumidityAcoustic

32°Fto113°F(0°Cto45°C)10%to90%,noncondensingLow-Speed:59.4dB,High-Speed:72.4dB

32°Fto113°F(0°Cto45°C)10%to95%,noncondensingLow-Speed:62.6dB,High-Speed:74.4dB

32°Fto113°F(0°Cto45°C)10%to90%,noncondensingLow-Speed:65dB,High-Speed:78dB

HPE FlexFabric 5940 Switch Series

Specifications

Page 8: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 8Data sheet

HPE FlexFabric 5940 48SFP+ 6QSFP+ Switch (JH395A)

HPE FlexFabric 5940 32QSFP+ Switch (JH396A)

HPE FlexFabric 5940 48XGT 6QSFP+ Switch (JH394A)

Electrical characteristicsFrequencyMaximumheatdissipationVoltage

MaximumpowerratingNotes

50/60Hz512BTU/hr(540.19kJ/hr)100–240VAC,rated-40to-60VDC,rated(dependingonpowersupplychosen)150WMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

50/60Hz1027BTU/hr(1083.54kJ/hr)100–240VAC,rated-40to-60VDC,rated(dependingonpowersupplychosen)301WMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

50/60Hz912BTU/hr(962.21kJ/hr)100–240VAC,rated-40to-60VDC,rated(dependingonpowersupplychosen)270WMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

Emissions VCCIClassA;EN55022ClassA;ICES-003ClassA;ANSIC63.4 2003;AS/NZSCISPR22ClassA;EN61000-3-2:2006;EN61000-3-3:1995+A1:2001+A2:2005;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

VCCIClassA;EN55022ClassA;ICES-003ClassA;ANSIC63.4 2003;AS/NZSCISPR22ClassA;EN61000-3-2:2006;EN61000-3-3:1995+A1:2001+A2:2005;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

VCCIClassA;EN55022ClassA;ICES-003ClassA;ANSIC63.4 2003;AS/NZSCISPR22ClassA;EN61000-3-2:2006;EN61000-3-3:1995+A1:2001+A2:2005;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

HPE FlexFabric 5940 Switch Series

Specifications (continued)

Page 9: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 9Data sheet

HPE FlexFabric 5940 48SFP+ 6QSFP+ Switch (JH395A)

HPE FlexFabric 5940 32QSFP+ Switch (JH396A)

HPE FlexFabric 5940 48XGT 6QSFP+ Switch (JH394A)

ImmunityGenericENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptionsHarmonicsFlicker

ETSIEN300 386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2;IEC61000-3-2EN61000-3-3;IEC61000-3-3

ETSIEN300 386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2;IEC61000-3-2EN61000-3-3;IEC61000-3-3

ETSIEN300 386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2;IEC61000-3-2EN61000-3-3;IEC61000-3-3

Management IMC—IntelligentManagementCenter;Command-lineinterface;Out-of-bandmanagement;SNMPmanager;Telnet;FTP

IMC—IntelligentManagementCenter;Command-lineinterface;Out-of-bandmanagement;SNMPmanager;Telnet;FTP

IMC—IntelligentManagementCenter;Command-lineinterface;Out-of-bandmanagement;SNMPmanager;Telnet;FTP

Notes Thecustomermustorderapowersupply,asthedevicedoesnotcomewithone.AtleastoneJC680AorJH336Aisrequired.

Thecustomermustorderapowersupply,asthedevicedoesnotcomewithone.AtleastoneJC680AorJH336Aisrequired.

Thecustomermustorderapowersupply,asthedevicedoesnotcomewithone.AtleastoneJC680AorJH336Aisrequired.

Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

HPE FlexFabric 5940 Switch Series

Specifications (continued)

Page 10: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 10Data sheet

HPE FlexFabric 5940 48SFP+ 6QSFP28 Switch (JH390A) HPE FlexFabric 5940 48XGT 6QSFP28 Switch (JH391A)

I/O ports and slots 48fixed1000/10000SFP+ports6QSFP28 100GbEports

48 1/10GBASE-Tports6QSFP28 100GbEports

Additional ports and slots 1RJ-45and1MiniUSBserialconsoleport1RJ-45and1SFPout-of-bandmanagementport1USB2.0

1RJ-45and1MiniUSBserialconsoleport1RJ-45and1SFP+out-of-bandmanagementport1USB2.0

Power supplies 2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

Fan tray 2fantrayslotsThecustomermustorderfantrays,asfantraysarenotincludedwiththeswitch.Thissystemrequirestwosame-directionairflowfantraystofunctionproperly.Thesystemshouldnotbeoperatedwithonlyonefantrayformorethan24hours.Thesystemshouldnotbeoperatedwithoutafantrayformorethantwominutes.Thesystemshouldnotbeoperatedoutsideofthetemperaturerangeof32°F(0°C)to113°F(45°C).Failuretocomplywiththeseoperatingrequirementsmayvoidtheproductwarranty.

2fantrayslotsThecustomermustorderfantrays,asfantraysarenotincludedwiththeswitch.Thissystemrequirestwosame-directionairflowfantraystofunctionproperly.Thesystemshouldnotbeoperatedwithonlyonefantrayformorethan24hours.Thesystemshouldnotbeoperatedwithoutafantrayformorethantwominutes.Thesystemshouldnotbeoperatedoutsideofthetemperaturerangeof32°F(0°C)to113°F(45°C).Failuretocomplywiththeseoperatingrequirementsmayvoidtheproductwarranty.

Physical characteristicsDimensionsWeight

17.32(w)x18.11(d)x1.72(h)in.(44x46x4.36cm)24.25lb(11kg)shippingweight

17.32(w)x25.98(d)x1.72(h)in.(44x66x4.36cm)28.66lb(13kg)shippingweight

Memory and processor 1GBflash;Packetbuffersize:16MB,4GBSDRAM 1GBflash;Packetbuffersize:16MB,4GBSDRAM

Performance10GbpsLatencyThroughputRouting/SwitchingcapacityRoutingtablesizeMACaddresstablesize

<1µs(64-bytepackets)Upto1607Mpps2160Gbps250Kentries(IPv4),64Kentries(IPv6)288Kentries

<1µs(64-bytepackets)Upto1607Mpps2160Gbps250Kentries(IPv4),64Kentries(IPv6)288Kentries

EnvironmentOperatingtemperatureOperatingrelativehumidityAcoustic

32°Fto113°F(0°Cto45°C)10%to90%,noncondensingLow-Speed:60.1dB,High-Speed:75.9dB

32°Fto113°F(0°Cto45°C)10%to90%,noncondensingLow-Speed:57.4dB,High-Speed:66.1dB

HPE FlexFabric 5940 Switch Series

Specifications (continued)

Page 11: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 11Data sheet

HPE FlexFabric 5940 48SFP+ 6QSFP28 Switch (JH390A) HPE FlexFabric 5940 48XGT 6QSFP28 Switch (JH391A)

Electrical characteristicsFrequencyMaximumheatdissipationVoltage

MaximumpowerratingNotes

50/60Hz669BTU/hr(705.83kJ/hr)100–240VAC,rated-40to-60VDC,rated(dependingonpowersupplychosen)196WMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

50/60Hz1092BTU/hr(1152.12kJ/hr)100–240VAC,rated-40to-60VDC,rated(dependingonpowersupplychosen)320WMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

Emissions VCCIClassA;EN55022ClassA;ICES-003ClassA;ANSIC63.4 2003;AS/NZSCISPR22ClassA;EN61000-3-2:2006;EN61000-3-3:1995+A1:2001+A2:2005;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

VCCIClassA;EN55022ClassA;ICES-003ClassA;ANSIC63.4 2003;AS/NZSCISPR22ClassA;EN61000-3-2:2006;EN61000-3-3:1995+A1:2001+A2:2005;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

ImmunityGenericENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptionsHarmonicsFlicker

ETSIEN300 386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2;IEC61000-3-2EN61000-3-3;IEC61000-3-3

ETSIEN300 386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2;IEC61000-3-2EN61000-3-3;IEC61000-3-3

Management IMC—IntelligentManagementCenter;Command-lineinterface;Out-of-bandmanagement;SNMPmanager;Telnet;FTP

IMC—IntelligentManagementCenter;Command-lineinterface;Out-of-bandmanagement;SNMPmanager;Telnet;FTP

Notes Thecustomermustorderapowersupply,asthedevicedoesnotcomewithone.AtleastoneJC680AorJH336Aisrequired.

Thecustomermustorderapowersupply,asthedevicedoesnotcomewithone.AtleastoneJC680AorJH336Aisrequired.

Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

HPE FlexFabric 5940 Switch Series

Specifications (continued)

Page 12: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 12Data sheet

HPE FlexFabric 5940 2-slot Switch (JH397A) HPE FlexFabric 5940 4-slot Switch (JH398A)

I/O ports and slots 2moduleslots2QSFP+40GbEportsSupportsamaximumof18 40GbEportsor48 1/10GBASE-Tportsor48SFP+portsor48Convergedports,oracombination

4moduleslotsSupportsamaximumof32 40GbEportsor96 1/10GBASE-Tportsor96SFP+portsor96Convergedports,oracombination

Additional ports and slots 1RJ-45and1MiniUSB2.0serialconsoleport1RJ-45out-of-bandmanagementport1USB2.0

1RJ-45and1MiniUSB2.0serialconsoleport1RJ-45out-of-bandmanagementport1USB2.0

Power supplies 2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

4powersupplyslots2minimumpowersuppliesrequired(orderedseparately)

Fan tray 2fantrayslotsThecustomermustorderfantrays,asfantraysarenotincludedwiththeswitch.Thissystemrequirestwosame-directionairflowfantraystofunctionproperly.Thesystemshouldnotbeoperatedwithonlyonefantrayformorethan24hours.Thesystemshouldnotbeoperatedwithoutafantrayformorethantwominutes.Thesystemshouldnotbeoperatedoutsideofthetemperaturerangeof32°F(0°C)to113°F(45°C).Failuretocomplywiththeseoperatingrequirementsmayvoidtheproductwarranty.

2fantrayslotsThecustomermustorderfantrays,asfantraysarenotincludedwiththeswitch.Thissystemrequirestwosame-directionairflowfantraystofunctionproperly.Thesystemshouldnotbeoperatedwithonlyonefantrayformorethan24hours.Thesystemshouldnotbeoperatedwithoutafantrayformorethantwominutes.Thesystemshouldnotbeoperatedoutsideofthetemperaturerangeof32°F(0°C)to113°F(45°C).Failuretocomplywiththeseoperatingrequirementsmayvoidtheproductwarranty.

Physical characteristicsDimensions

WeightFullconfigurationweight

17.32(w)x25.98(d)x1.74(h)in.(44.00x66.0x4.42cm)(1Uheight)39.68lb(18kg)shippingweight35.27lb(16kg)

17.32(w)x25.98(d)x3.47(h)in.(44.00x66.0x8.81cm)(2Uheight)66.14lb(30kg)shippingweight59.52lb(27kg)

Memory and processor 1GBflash;Packetbuffersize:16MB,4GBSDRAM 1GBflash;Packetbuffersize:16MB,4GBSDRAM

Performance10GbpsLatencyThroughputRouting/SwitchingcapacityRoutingtablesizeMACaddresstablesize

<1µs(64-bytepackets)Upto1071Mpps1440Gbps250Kentries(IPv4),64Kentries(IPv6)288Kentries

<1µs(64-bytepackets)Upto1904Mpps2560Gbps250Kentries(IPv4),64Kentries(IPv6)288Kentries

ReliabilityMTBF(years)MTTR(hours)

47.21

35.81

EnvironmentOperatingtemperatureOperatingrelativehumidityAcoustic

32°Fto113°F(0°Cto45°C)10%to90%,noncondensingLow-Speed:69.8dB,High-Speed:82.2dB

32°Fto113°F(0°Cto45°C)10%to90%,noncondensingLow-Speed:61.3dB,High-Speed:78.4dB

HPE FlexFabric 5940 Switch Series

Specifications (continued)

Page 13: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 13Data sheet

HPE FlexFabric 5940 2-slot Switch (JH397A) HPE FlexFabric 5940 4-slot Switch (JH398A)

Electrical characteristicsFrequencyMaximumheatdissipationVoltage

MaximumpowerratingIdlepowerNotes

50/60Hz2921BTU/hr100–240VAC,rated-40to-60VDC,rated(dependingonpowersupplychosen)450W105WIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

50/60Hz1535BTU/hr100–240VAC,rated-40to-60VDC,rated(dependingonpowersupplychosen)856W139WIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

Emissions VCCIClassA;EN55022ClassA;ICES-003ClassA;ANSIC63.4 2003;AS/NZSCISPR22ClassA;EN61000-3-2:2006;EN61000-3-3:1995+A1:2001+A2:2005;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

VCCIClassA;EN55022ClassA;ICES-003ClassA;ANSIC63.4 2003;AS/NZSCISPR22ClassA;EN61000-3-2:2006;EN61000-3-3:1995+A1:2001+A2:2005;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

ImmunityGenericENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptionsHarmonicsFlicker

ETSIEN300 386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

ETSIEN300 386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

Management IMC—IntelligentManagementCenter;Command-lineinterface;Out-of-bandmanagement;SNMPmanager;Telnet;FTP

IMC—IntelligentManagementCenter;Command-lineinterface;Out-of-bandmanagement;SNMPmanager;Telnet;FTP

Notes Thecustomermustorderapowersupply,asthedevicedoesnotcomewithone.AtleastoneJC680AorJC336Aisrequired.

Services RefertotheHewlettPackardEnterprisewebsiteat hpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

HPE FlexFabric 5940 Switch Series

Specifications (continued)

Page 14: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 14Data sheet

Standards and protocols(Appliestoallproductsinseries)

BGP RFC1163BorderGatewayProtocol(BGP)RFC1771BGPv4RFC1997BGPCommunitiesAttributeRFC2918RouteRefreshCapability

RFC3392CapabilitiesAdvertisementwithBGP-4RFC4271ABorderGatewayProtocol4(BGP-4)RFC4360BGPExtendedCommunitiesAttribute

RFC4456BGPRouteReflection:AnAlternativetoFullMeshInternalBGP(IBGP)RFC4760MultiprotocolExtensionsforBGP-4RFC7432BGPMPLS-BasedEthernetVPN

Device management RFC1157SNMPv1/v2cRFC1305NTPv3RFC1591DNS(client)RFC1902(SNMPv2)

RFC1908(SNMPv1/2Coexistence)RFC2573(SNMPv3Applications)RFC2576(CoexistencebetweenSNMPv1,v2,andv3)RFC2819RMON

MultipleConfigurationFilesMultipleSoftwareImagesSSHv1/SSHv2SecureShellTACACS/TACACS+

General protocols IEEE802.1adQ-in-QIEEE802.1AX-2008LinkAggregationIEEE802.1DMACBridgesIEEE802.1pPriorityIEEE802.1QVLANsIEEE802.1sMultipleSpanningTreesIEEE802.1wRapidReconfigurationofSpanningTreeIEEE802.3adLinkAggregationControlProtocol(LACP)IEEE802.3ae10-GigabitEthernetIEEE802.3agEthernetOAMIEEE802.3ahEthernetinFirstMileoverPointtoPointFiber—EFMFIEEE802.3xFlowControlRFC768UDPRFC783TFTPProtocol(revision2)RFC791IPRFC792ICMPRFC793TCPRFC826ARPRFC854TELNETRFC856TELNETRFC868TimeProtocolRFC896CongestionControlinIP/TCPInternetworksRFC950InternetStandardSubnettingProcedureRFC1027ProxyARPRFC1058RIPv1RFC1091TelnetTerminal-TypeOptionRFC1141IncrementalupdatingoftheInternetchecksumRFC1142OSIIS-ISIntra-domainRoutingProtocolRFC1191PathMTUdiscovery

RFC1213ManagementInformationBaseforNetworkManagementofTCP/IP-basedInternetsRFC1253(OSPFv2)RFC1531DynamicHostConfigurationProtocolRFC1533DHCPOptionsandBOOTPVendorExtensionsRFC1534DHCP/BOOTPInteroperationRFC1541DHCPRFC1542ClarificationsandExtensionsfortheBootstrapProtocolRFC1591DNS(clientonly)RFC1624IncrementalInternetChecksumRFC1723RIPv2RFC1812IPv4RoutingRFC2030SimpleNetworkTimeProtocol(SNTP)v4RFC2131DHCPRFC2236IGMPSnoopingRFC2338VRRPRFC2453RIPv2RFC2581TCPCongestionControlRFC2644DirectedBroadcastControlRFC2767DualStacksIPv4&IPv6RFC2865RemoteAuthenticationDialInUserService(RADIUS)RFC2868RADIUSAttributesforTunnelProtocolSupportRFC2890KeyandSequenceNumberExtensionstoGRERFC3046DHCPRelayAgentInformationOptionRFC3411anArchitectureforDescribingSimpleNetworkManagementProtocol(SNMP)ManagementFrameworksRFC3412MessageProcessingandDispatchingfortheSimpleNetworkManagementProtocol(SNMP)

RFC3413SimpleNetworkManagementProtocol(SNMP)ApplicationsRFC3416ProtocolOperationsforSNMPRFC3417TransportMappingsfortheSimpleNetworkManagementProtocol(SNMP)RFC3418ManagementInformationBase(MIB)fortheSimpleNetworkManagementProtocol(SNMP)RFC3768VirtualRouterRedundancyProtocol(VRRP)RFC4250TheSecureShell(SSH)ProtocolAssignedNumbersRFC4251TheSecureShell(SSH)ProtocolArchitectureRFC4252TheSecureShell(SSH)AuthenticationProtocolRFC4253TheSecureShell(SSH)TransportLayerProtocolRFC4254TheSecureShell(SSH)ConnectionProtocolRFC4292IPForwardingTableMIBRFC4293ManagementInformationBasefortheInternetProtocol(IP)RFC4364BGP/MPLSIPVirtualPrivateNetworks(VPNs)RFC4419Diffie-HellmanGroupExchangefortheSecureShell(SSH)TransportLayerProtocolRFC4594ConfigurationGuidelinesforDiffServServiceClassesRFC4601ProtocolIndependentMulticast-SparseMode(PIM-SM):ProtocolSpecification(revised)RFC4604UsingInternetGroupManagementProtocolVersion3(IGMPv3)andMulticastListenerDiscoveryProtocolVersion2(MLDv2)forSource-SpecificMulticastRFC4607Source-SpecificMulticastforIPRFC4941PrivacyExtensionsforStatelessAddressAuto-configurationinIPv6RFC5340OSPFforIPv6RFC5905NetworkTimeProtocolVersion4:ProtocolandAlgorithmsSpecificationRFC2929DNSIANAConsiderations

Page 15: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 15Data sheet

Standards and protocols(Appliestoallproductsinseries)(continued)

IPv6 RFC2080RIPngforIPv6RFC2460IPv6SpecificationRFC2461IPv6NeighborDiscoveryRFC2462IPv6StatelessAddressAuto-configurationRFC2463ICMPv6RFC2464TransmissionofIPv6overEthernetNetworksRFC2473GenericPacketTunnelinginIPv6RFC2545UseofMP-BGP-4forIPv6

RFC2563ICMPv6RFC2711IPv6RouterAlertOptionRFC2740OSPFv3forIPv6RFC2767DualStackHostsusingBISRFC3315DHCPv6(clientandrelay)RFC3484DefaultAddressSelectionforIPv6RFC3810MulticastListenerDiscoveryVersion2(MLDv2)forIPv6

RFC4213BasicTransitionMechanismsforIPv6HostsandRoutersRFC4291IPVersion6AddressingArchitectureRFC4443ICMPv6RFC4552Authentication/ConfidentialityforOSPFv3RFC4862IPv6StatelessAddressAuto-configurationRFC5095DeprecationofType0RoutingHeadersinIPv6

MIBs RFC1213MIBIIRFC1907SNMPv2MIBRFC2571SNMPFrameworkMIBRFC2572SNMP-MPDMIB

RFC2573SNMP-NotificationMIBRFC2573SNMP-TargetMIBRFC2574SNMPUSMMIBRFC2737EntityMIB(version2)

RFC3414SNMP-User-based-SMMIBRFC3415SNMP-View-based-ACMMIBLLDP-EXT-DOT1-MIBLLDP-EXT-DOT3-MIBLLDP-MIB

Network management RFC2580ConformanceStatementsforSMIv2 RFC3164BSDsyslogProtocol

OSPF RFC1587OSPFNSSARFC2328OSPFv2RFC3101OSPFNSSA

RFC3137OSPFStubRouterAdvertisementRFC3623GracefulOSPFRestartRFC4577OSPFastheProvider/CustomerEdgeProtocolforBGP/MPLSIPVirtualPrivateNetworks(VPNs)

RFC4811OSPFOut-of-BandLSDBResynchronizationRFC4812OSPFRestartSignalingRFC4813OSPFLink-LocalSignaling

QoS/CoS IEEE802.1p(CoS)RFC2475DiffServArchitecture

RFC2597DiffServAssuredForwarding(AF) RFC3247SupplementalInformationfortheNewDefinitionoftheEFPHB(ExpeditedForwardingPer-HopBehavior)RFC3260NewTerminologyandClarificationsforDiffServ

Security RFC1321TheMD5Message-DigestAlgorithmRFC2818HTTPOverTLS

RFC6192PartialSupport—ProtectingtheRouterControlPlane

Accesscontrollists(ACLs)SSHv2SecureShell

Page 16: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 16Data sheet

HPE FlexFabric 5940 Switch Series accessories

HPE FlexFabric 5940 48SFP+ 6QSFP+ Switch (JH395A)HPEX120 1GSFPRJ45TTransceiver(JD089B)

HPEX120 1GSFPLCSXTransceiver(JD118B)

HPEX120 1GSFPLCLXTransceiver(JD119B)

HPEX125 1GSFPLCLH40 1310nmTransceiver(JD061A)

HPEX120 1GSFPLCLH40 1550nmTransceiver(JD062A)

HPEX125 1GSFPLCLH80Transceiver(JD063B)

HPEX130 10GSFP+LCSRTransceiver(JD092B)

HPEX130 10GSFP+LCLRTransceiver(JD094B)

HPEX240 10GSFP+SFP+3mDACable(JD097C)

HPEX240SFP+SFP+5mDACCable(JG081C)

HPEX240 10GSFP+SFP+0.65mDACable(JD095C)

HPEX240 10GSFP+SFP+1.2mDACable(JD096C)

HPEX2A0 10GSFP+toSFP+7mActiveOpticalCable(JL290A)

HPEX2A0 10GSFP+toSFP+10mActiveOpticalCable(JL291A)

HPEX2A0 10GSFP+toSFP+20mActiveOpticalCable(JL292A)

HPEX140 40GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

HPEX140 40GQSFP+MPOMM850nmCSR4 300mTransceiver(JG709A)

HPEX140 40GQSFP+MPOSR4Transceiver(JG325B)

HPEX140 40GQSFP+LCBiDi100mMMTransceiver(JL251A)

HPEX140 40GQSFP+LCLR4L2kmSMTransceiver(JL286A)

HPEX140 40GQSFP+LCER4 40kmSMTransceiver(JL306A)

HPEX240 40GQSFP+QSFP+1mDACCable(JG326A)

HPEX240 40GQSFP+QSFP+3mDACCable(JG327A)

HPEX240 40GQSFP+QSFP+5mDACCable(JG328A)

HPEX240QSFP+4x10GSFP+1mDACCable(JG329A)

HPEX240QSFP+4x10GSFP+3mDACCable(JG330A)

HPEX240QSFP+4x10GSFP+5mDACCable(JG331A)

HPEX2A0 40GQSFP+toQSFP+7mActiveOpticalCable(JL287A)

HPEX2A0 40GQSFP+toQSFP+10mActiveOpticalCable(JL288A)

HPEX2A0 40GQSFP+toQSFP+20mActiveOpticalCable(JL289A)

HPE58x0AFBack(PowerSide)toFront(PortSide)Airflow300WACPowerSupply(JG900A)

HPE58x0AFBack(PowerSide)toFront(PortSide)Airflow300WDCPowerSupply(JG901A)

Page 17: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 17Data sheet

HPE58x0AF650WACPowerSupply(JC680A)

HPEFlexFabricSwitch650W48VHotPlugNEBS-compliantDCPowerSupply

HPE58x0AFBack(powerside)toFront(portside)AirflowFanTray(JC682A)

HPE58x0AFFront(portside)toBack(powerside)AirflowFanTray(JC683A)

HPEX711Front(portside)toBack(powerside)AirflowHighVolumeFanTray(JG552A)

HPEX712Back(powerside)toFront(portside)AirflowHighVolumeFanTray(JG553A)

HPE FlexFabric 5940 32QSFP+ Switch (JH396A)HPEX140 40GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

HPEX140 40GQSFP+MPOMM850nmCSR4 300mTransceiver(JG709A)

HPEX140 40GQSFP+MPOSR4Transceiver(JG325B)

HPEX140 40GQSFP+LCBiDi100mMMTransceiver(JL251A)

HPEX140 40GQSFP+LCLR4L2kmSMTransceiver(JL286A)

HPEX140 40GQSFP+LCER4 40kmSMTransceiver(JL306A)

HPEX240 40GQSFP+QSFP+1mDACCable(JG326A)

HPEX240 40GQSFP+QSFP+3mDACCable(JG327A)

HPEX240 40GQSFP+QSFP+5mDACCable(JG328A)

HPEX240QSFP+4x10GSFP+1mDACCable(JG329A)

HPEX240QSFP+4x10GSFP+3mDACCable(JG330A)

HPEX240QSFP+4x10GSFP+5mDACCable(JG331A)

HPEX2A0 40GQSFP+toQSFP+7mActiveOpticalCable(JL287A)

HPEX2A0 40GQSFP+toQSFP+10mActiveOpticalCable(JL288A)

HPEX2A0 40GQSFP+toQSFP+20mActiveOpticalCable(JL289A)

HPE58x0AF650WACPowerSupply(JC680A)

HPEFlexFabricSwitch650W48VHotPlugNEBS-compliantDCPowerSupply

HPEX711Front(portside)toBack(powerside)AirflowHighVolumeFanTray(JG552A)

HPEX712Back(powerside)toFront(portside)AirflowHighVolumeFanTray(JG553A)

HPE FlexFabric 5940 48XGT 6QSFP+ Switch (JH394A)HPEX140 40GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

HPEX140 40GQSFP+MPOMM850nmCSR4 300mTransceiver(JG709A)

HPEX140 40GQSFP+MPOSR4Transceiver(JG325B)

HPEX140 40GQSFP+LCBiDi100mMMTransceiver(JL251A)

HPEX140 40GQSFP+LCLR4L2kmSMTransceiver(JL286A)

HPEX140 40GQSFP+LCER4 40kmSMTransceiver(JL306A)

HPEX240 40GQSFP+QSFP+1mDACCable(JG326A)

Page 18: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 18Data sheet

HPEX240 40GQSFP+QSFP+3mDACCable(JG327A)

HPEX240 40GQSFP+QSFP+5mDACCable(JG328A)

HPEX240QSFP+4x10GSFP+1mDACCable(JG329A)

HPEX240QSFP+4x10GSFP+3mDACCable(JG330A)

HPEX240QSFP+4x10GSFP+5mDACCable(JG331A)

HPEX2A0 40GQSFP+toQSFP+7mActiveOpticalCable(JL287A)

HPEX2A0 40GQSFP+toQSFP+10mActiveOpticalCable(JL288A)

HPEX2A0 40GQSFP+toQSFP+20mActiveOpticalCable(JL289A)

HPE58x0AF650WACPowerSupply(JC680A)

HPEFlexFabricSwitch650W48VHotPlugNEBS-compliantDCPowerSupply

HPEX711Front(portside)toBack(powerside)AirflowHighVolumeFanTray(JG552A)

HPEX712Back(powerside)toFront(portside)AirflowHighVolumeFanTray(JG553A)

HPE FlexFabric 5940 48SFP+ 6QSFP28 Switch (JH390A)HPEX120 1GSFPRJ45TTransceiver(JD089B)

HPEX120 1GSFPLCSXTransceiver(JD118B)

HPEX120 1GSFPLCLXTransceiver(JD119B)

HPEX125 1GSFPLCLH40 1310nmTransceiver(JD061A)

HPEX120 1GSFPLCLH40 1550nmTransceiver(JD062A)

HPEX125 1GSFPLCLH80Transceiver(JD063B)

HPEX130 10GSFP+LCSRTransceiver(JD092B)

HPEX130 10GSFP+LCLRTransceiver(JD094B)

HPEX240 10GSFP+SFP+3mDACable(JD097C)

HPEX240SFP+SFP+5mDACCable(JG081C)

HPEX240 10GSFP+SFP+0.65mDACable(JD095C)

HPEX240 10GSFP+SFP+1.2mDACable(JD096C)

HPEX2A0 10GSFP+toSFP+7mActiveOpticalCable(JL290A)

HPEX2A0 10GSFP+toSFP+10mActiveOpticalCable(JL291A)

HPEX2A0 10GSFP+toSFP+20mActiveOpticalCable(JL292A)

HPEX140 40GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

HPEX140 40GQSFP+MPOMM850nmCSR4 300mTransceiver(JG709A)

HPEX140 40GQSFP+MPOSR4Transceiver(JG325B)

HPEX140 40GQSFP+LCBiDi100mMMTransceiver(JL251A)

HPEX140 40GQSFP+LCLR4L2kmSMTransceiver(JL286A)

Page 19: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 19Data sheet

HPEX140 40GQSFP+LCER4 40kmSMTransceiver(JL306A)

HPEX240 40GQSFP+QSFP+1mDACCable(JG326A)

HPEX240 40GQSFP+QSFP+3mDACCable(JG327A)

HPEX240 40GQSFP+QSFP+5mDACCable(JG328A)

HPEX150 100GQSFP28MPOSR4 100mMMTransceiver(JL274A)

HPEX150 100GQSFP28LCLR4 10kmSMTransceiver(JL275A)

HPEX150 100GQSFP28LCSWDM4100mMMTransceiver(JH419A)

HPEX150 100GQSFP28MPOPSM4500mSMTransceiver(JH420A)

HPEX150 100GQSFP28CWDM4 2kmSMTransceiver(JH673A)

HPEX240 100GQSFP28toQSFP28 1mDirectAttachCopperCable(JL271A)

HPEX240 100GQSFP28 3mDACCable(JL272A)

HPEX240 100GQSFP28toQSFP28 5mDirectAttachCopperCable(JL273A)

HPE58x0AFBack(PowerSide)toFront(PortSide)Airflow300WACPowerSupply(JG900A)

HPE58x0AFBack(PowerSide)toFront(PortSide)Airflow300WDCPowerSupply(JG901A)

HPE58x0AF650WACPowerSupply(JC680A)

HPEFlexFabricSwitch650W48VHotPlugNEBS-compliantDCPowerSupply

HPE58x0AFBack(powerside)toFront(portside)AirflowFanTray(JC682A)

HPE58x0AFFront(portside)toBack(powerside)AirflowFanTray(JC683A)

HPEX711Front(portside)toBack(powerside)AirflowHighVolumeFanTray(JG552A)

HPEX712Back(powerside)toFront(portside)AirflowHighVolumeFanTray(JG553A)

HPE FlexFabric 5940 48XGT 6QSFP28 Switch (JH391A)HPEX140 40GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

HPEX140 40GQSFP+MPOMM850nmCSR4 300mTransceiver(JG709A)

HPEX140 40GQSFP+MPOSR4Transceiver(JG325B)

HPEX140 40GQSFP+LCBiDi100mMMTransceiver(JL251A)

HPEX140 40GQSFP+LCLR4L2kmSMTransceiver(JL286A)

HPEX140 40GQSFP+LCER4 40kmSMTransceiver(JL306A)

HPEX240 40GQSFP+QSFP+1mDACCable(JG326A)

HPEX240 40GQSFP+QSFP+3mDACCable(JG327A)

HPEX240 40GQSFP+QSFP+5mDACCable(JG328A)

Page 20: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 20Data sheet

HPEX150 100GQSFP28MPOSR4 100mMMTransceiver(JL274A)

HPEX150 100GQSFP28LCLR4 10kmSMTransceiver(JL275A)

HPEX150 100GQSFP28LCSWDM4 100mMMTransceiver(JH419A)

HPEX150 100GQSFP28MPOPSM4 500mSMTransceiver(JH420A)

HPEX150 100GQSFP28CWDM4 2kmSMTransceiver(JH673A)

HPEX240 100GQSFP28toQSFP28 1mDirectAttachCopperCable(JL271A)

HPEX240 100GQSFP28 3mDACCable(JL272A)

HPEX240 100GQSFP28toQSFP28 5mDirectAttachCopperCable(JL273A)

HPE58x0AF650WACPowerSupply(JC680A)

HPEFlexFabricSwitch650W48VHotPlugNEBS-compliantDCPowerSupply

HPEX711Front(portside)toBack(powerside)AirflowHighVolumeFanTray(JG552A)

HPEX712Back(powerside)toFront(portside)AirflowHighVolumeFanTray(JG553A)

HPE FlexFabric 5940 2-slot Switch (JH397A)HPEX240 10GSFP+SFP+5mDACCable(JG081C)

HPEX240 10GSFP+SFP+0.65mDACCable(JD095C)

HPEX130 10GSFP+LCLH80kmTransceiver—onlyonportswithPHY(JG915A)

HPEFlexFabricSwitch650W48VHotPlugNEBS-compliantDCPowerSupply

HPE5930 24-portSFP+and2-portQSFP+Module(JH180A)

HPE5930 24-portSFP+and2-portQSFP+withMACsecModule(JH181A)

HPE5930 24-port10GBASE-Tand2-portQSFP+withMACsecModule(JH182A)

HPE5930 8-portQSFP+Module(JH183A)

HPE5930 24-portConvergedPortand2-portQSFP+Module(JH184A)

HPE5940 2-portQSFP+and2-portQSFP28Module(JH409A)

HPEFlexFabric5950 8-portQSFP28MACsecModule(JH957A)

HPEX125 1GSFPLCLH40 1310nmTransceiver(JD061A)

HPEX120 1GSFPLCLH40 1550nmTransceiver(JD062A)

HPEX125 1GSFPLCLH70Transceiver(JD063B)

HPEX120 1GSFPRJ45TTransceiver(JD089B)

HPEX120 1GSFPLCSXTransceiver(JD118B)

HPEX120 1GSFPLCLXTransceiver(JD119B)

HPEX240 10GSFP+SFP+7mDirectAttachCopperCable(JC784C)

Page 21: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 21Data sheet

HPEX130 10GSFP+LCSRTransceiver(JD092B)

HPEX130 10GSFP+LCLRTransceiver(JD094B)

HPEX240 10GSFP+toSFP+1.2mDirectAttachCopperCable(JD096C)

HPEX240 10GSFP+toSFP+3mDirectAttachCopperCable(JD097C)

HPEX130 10GSFP+LCER40kmTransceiver(JG234A)

HPEX130 10GSFP+LCLH80TunableTransceiver(JL250A)

HPEX2A0 10GSFP+toSFP+7mActiveOpticalCable(JL290A)

HPEX2A0 10GSFP+toSFP+10mActiveOpticalCable(JL291A)

HPEX2A0 10GSFP+toSFP+20mActiveOpticalCable(JL292A)

HPEX140 40GQSFP+MPOSR4Transceiver(JG325B)

HPEX240 40GQSFP+toQSFP+1mDirectAttachCopperCable(JG326A)

HPEX240 40GQSFP+toQSFP+3mDirectAttachCopperCable(JG327A)

HPEX240 40GQSFP+toQSFP+5mDirectAttachCopperCable(JG328A)

HPEX240 40GQSFP+to4x10GSFP+1mDirectAttachCopperSplitterCable(JG329A)

HPEX240 40GQSFP+to4x10GSFP+3mDirectAttachCopperSplitterCable(JG330A)

HPEX240 40GQSFP+to4x10GSFP+5mDirectAttachCopperSplitterCable(JG331A)

HPEX140 40GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

HPEX140 40GQSFP+MPOMM850nmCSR4 300mTransceiver(JG709A)

HPEX140 40GQSFP+LCBiDi100mMMTransceiver(JL251A)

HPEX140 40GQSFP+LCLR4L2kmSMTransceiver(JL286A)

HPEX2A0 40GQSFP+toQSFP+7mActiveOpticalCable(JL287A)

HPEX2A0 40GQSFP+toQSFP+10mActiveOpticalCable(JL288A)

HPEX2A0 40GQSFP+toQSFP+20mActiveOpticalCable(JL289A)

HPEX240 100GQSFP28toQSFP28 5mDirectAttachCopperCable(JL273A)

HPEX240 100GQSFP28toQSFP28 1mDirectAttachCopperCable(JL271A)

HPEX240 100GQSFP28toQSFP28 3mDirectAttachCopperCable(JL272A)

HPEX150 100GQSFP28MPOSR4 100mMMTransceiver(JL274A)

HPEX150 100GQSFP28LCLR4 10kmSMTransceiver(JL275A)

HPEX150 100GQSFP28LCSWDM4100mMMTransceiver(JH419A)

HPEX150 100GQSFP28CWDM4 2kmSMTransceiver(JH673A)

HPE58x0AF650WACPowerSupply(JC680A)

HPEX711Front(portside)toBack(powerside)AirflowHighVolumeFanTray(JG552A)

HPEX712Back(powerside)toFront(portside)AirflowHighVolumeFanTray(JG553A)

Page 22: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 22Data sheet

HPE FlexFabric 5940 4-slot Switch (JH398A)HPEX240 10GSFP+SFP+5mDACCable(JG081C)

HPEX240 10GSFP+SFP+0.65mDACCable(JD095C)

HPEX130 10GSFP+LCLH80kmTransceiver—onlyonportswithPHY(JG915A)

HPEFlexFabricSwitch650W48VHotPlugNEBS-compliantDCPowerSupply

HPE5930 24-portSFP+and2-portQSFP+Module(JH180A)

HPE5930 24-portSFP+and2-portQSFP+withMACsecModule(JH181A)

HPE5940 2-portQSFP+and2-portQSFP28Module(JH409A)

HPE5930 24-port10GBASE-Tand2-portQSFP+withMACsecModule(JH182A)

HPE5930 8-portQSFP+Module(JH183A)

HPE5930 24-portConvergedPortand2-portQSFP+Module(JH184A)

HPEFlexFabric5950 8-portQSFP28MACsecModule(JH957A)

HPEX125 1GSFPLCLH40 1310nmTransceiver(JD061A)

HPEX120 1GSFPLCLH40 1550nmTransceiver(JD062A)

HPEX125 1GSFPLCLH70Transceiver(JD063B)

HPEX120 1GSFPRJ45TTransceiver(JD089B)

HPEX120 1GSFPLCSXTransceiver(JD118B)

HPEX120 1GSFPLCLXTransceiver(JD119B)

HPEX240 10GSFP+SFP+7mDirectAttachCopperCable(JC784C)

HPEX130 10GSFP+LCSRTransceiver(JD092B)

HPEX130 10GSFP+LCLRTransceiver(JD094B)

HPEX240 10GSFP+toSFP+1.2mDirectAttachCopperCable(JD096C)

HPEX240 10GSFP+toSFP+3mDirectAttachCopperCable(JD097C)

HPEX130 10GSFP+LCER40kmTransceiver(JG234A)

HPEX130 10GSFP+LCLH80TunableTransceiver(JL250A)

HPEX2A0 10GSFP+toSFP+7mActiveOpticalCable(JL290A)

HPEX2A0 10GSFP+toSFP+10mActiveOpticalCable(JL291A)

HPEX2A0 10GSFP+toSFP+20mActiveOpticalCable(JL292A)

HPEX140 40GQSFP+MPOSR4Transceiver(JG325B)

HPEX240 40GQSFP+toQSFP+1mDirectAttachCopperCable(JG326A)

HPEX240 40GQSFP+toQSFP+3mDirectAttachCopperCable(JG327A)

HPEX240 40GQSFP+toQSFP+5mDirectAttachCopperCable(JG328A)

HPEX240 40GQSFP+to4x10GSFP+1mDirectAttachCopperSplitterCable(JG329A)

HPEX240 40GQSFP+to4x10GSFP+3mDirectAttachCopperSplitterCable(JG330A)

HPEX240 40GQSFP+to4x10GSFP+5mDirectAttachCopperSplitterCable(JG331A)

Page 23: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Page 23Data sheet

HPEX140 40GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

HPEX140 40GQSFP+MPOMM850nmCSR4 300mTransceiver(JG709A)

HPEX140 40GQSFP+LCBiDi100mMMTransceiver(JL251A)

HPEX140 40GQSFP+LCLR4L2kmSMTransceiver(JL286A)

HPEX2A0 40GQSFP+toQSFP+7mActiveOpticalCable(JL287A)

HPEX2A0 40GQSFP+toQSFP+10mActiveOpticalCable(JL288A)

HPEX2A0 40GQSFP+toQSFP+20mActiveOpticalCable(JL289A)

HPEX240 100GQSFP28toQSFP28 5mDirectAttachCopperCable(JL273A)

HPEX240 100GQSFP28toQSFP28 1mDirectAttachCopperCable(JL271A)

HPEX240 100GQSFP28toQSFP28 3mDirectAttachCopperCable(JL272A)

HPEX150 100GQSFP28MPOSR4 100mMMTransceiver(JL274A)

HPEX150 100GQSFP28LCLR4 10kmSMTransceiver(JL275A)

HPEX150 100GQSFP28LCSWDM4100mMMTransceiver(JH419A)

HPEX150 100GQSFP28CWDM4 2kmSMTransceiver(JH673A)

HPE58x0AF650WACPowerSupply(JC680A)

HPEFlexFabric5930 4-slotBack(PowerSide)toFront(PortSide)AirflowFanTray(JH185A)

HPEFlexFabric5930 4-slotFront(PortSide)toBack(PowerSide)AirflowFanTray(JH186A)

Switch bundlesSelectHPEFlexFabricSwitch5940modelsareavailablewithpowersuppliesandfantraysincluded.

HPEFlexFabric5940 2-slot2QSFP+Front-to-BackACBundle(JQ041A):Includes(1)HPEFlexFabric5940 2-slotSwitch(JH397A),(2)powersupplies(JC680A),(2)front-to-backfantrays(JG552A).

HPEFlexFabric5940 2-slot2QSFP+Back-to-FrontACBundle(JQ042A):Includes(1)HPEFlexFabric5940 2-slotSwitch(JH397A),(2)powersupplies(JC680A),(2)back-to-frontfantrays(JG553A)

HPEFlexFabric5940 4-slotFront-to-BackACBundle(JQ043A):Includes(1)HPEFlexFabric5940 4-slotSwitch(JH398A),(4)powersupplies(JC680A),(2)front-to-backfantrays(JH186A)

HPEFlexFabric5940 4-slotBack-to-FrontACBundle(JQ044A):Includes(1)HPEFlexFabric5940 4-slotSwitch(JH398A),(4)powersupplies(JC680A),(2)back-to-frontfantrays(JH185A)

Learnmoreathpe.com/networking

Page 24: HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and egress port monitoring enable network problem solving – Traceroute and ping Enable

Sign up for updates

Make the right purchase decision. Click here to chat with our presales specialists.

Data sheet

©Copyright2016–2018HewlettPackardEnterpriseDevelopmentLP.Theinformationcontainedhereinissubjecttochangewithoutnotice.TheonlywarrantiesforHewlettPackardEnterpriseproductsandservicesaresetforthintheexpresswarrantystatementsaccompanyingsuchproductsandservices.Nothinghereinshouldbeconstruedasconstitutinganadditionalwarranty.HewlettPackardEnterpriseshallnotbeliablefortechnicaloreditorialerrorsoromissionscontainedherein.

TheOpenStackWordMarkiseitheraregisteredtrademark/servicemarkortrademark/servicemarkoftheOpenStackFoundation,intheUnitedStatesandothercountriesandisusedwiththeOpenStackFoundation’spermission.Wearenotaffiliatedwith,endorsedorsponsoredbytheOpenStackFoundation,ortheOpenStackcommunity.sFlowisaregisteredtrademarkofInMonCorp.Allotherthird-partytrademark(s)is/arepropertyoftheirrespectiveowner(s).

4AA6-6465ENN,May2018,Rev.11