Key features
•Fixed10Gportsforhigh-speedstackingoruplinks
•Supportformultipleservices
•Comprehensivesecuritycontrolpolicies
•Diversifiedqualityofservice(QoS)policies
•Excellentmanageability
Product overview
HP5130EIBrazilSwitchSeriescomprisesGigabitEthernetswitchesthatsupportstaticandRIPLayer3routing,diversifiedservices,andIPv6forwarding,aswellasprovidesfour10-GigabitEthernet(10GbE)extendedinterfaces.UniqueIntelligentResilientFramework(IRF)technologycreatesavirtualfabricbymanagingseveralswitchesasonelogicaldevice,whichincreasesnetworkresilience,performance,andavailability,whilereducingoperationalcomplexity.TheseswitchesprovideGigabitEthernetaccessandcanbeusedattheedgeofanetworkortoconnectserverclustersindatacenters.Highavailability,simplifiedmanagement,andcomprehensivesecuritycontrolpoliciesareamongthekeyfeaturesthatdistinguishthisseries.TheseproductsaremanufacturedinBrazil.
Data sheet
HP 5130 EI Brazil Switch Series
2
Features and benefits
Software-defined networking•OpenFlow
SupportsOpenFlow1.3specificationtoenableSDNbyallowingseparationofthedata(packetforwarding)andcontrol(routingdecision)paths
Quality of service (QoS)•Broadcastcontrol
Allowslimitationofbroadcasttrafficratetocutdownonunwantednetworkbroadcasttraffic
•Advancedclassifier-basedQoS
ClassifiestrafficusingmultiplematchcriteriabasedonLayer2,3,and4information;appliesQoSpoliciessuchassettingprioritylevelandratelimittoselectedtrafficonaport,VLAN,orwholeswitch
•PowerfulQoSfeature
Supportsthefollowingcongestionactions:strictpriority(SP)queuing,weightedroundrobin(WRR),andSP+WRR
•Trafficpolicing
SupportsCommittedAccessRate(CAR)andlinerate
Management•Remoteconfigurationandmanagement
EnablesconfigurationandmanagementthroughasecureWebbrowseroraCLIlocatedonaremotedevice
•Managerandoperatorprivilegelevels
Providesread-only(operator)andreadorwrite(manager)accessonCLIandWebbrowsermanagementinterfaces
•Commandauthorization
LeveragesHWTACACStolinkacustomlistofCLIcommandstoanindividualnetworkadministrator’slogin;alsoprovidesanaudittrail
•SecureWebGUI
Providesasecure,easy-to-usegraphicalinterfaceforconfiguringthemoduleviaHTTPS
•Multipleconfigurationfiles
Alloweasyconfigurationchanges
•Completesessionlogging
Providesdetailedinformationforproblemidentificationandresolution
•SNMPv1,v2c,andv3
Facilitatescentralizeddiscovery,monitoring,andsecuremanagementofnetworkingdevices
Datasheet|HP5130EIBrazilSwitchSeries
3
•Remotemonitoring(RMON)
UsesstandardSNMPtomonitoressentialnetworkfunctions;supportsevents,alarm,history,andstatisticsgroupplusaprivatealarmextensiongroup
•IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)
Advertisesandreceivesmanagementinformationfromadjacentdevicesonanetwork,facilitatingeasymappingbynetworkmanagementapplications
•sFlow(RFC3176)
ProvidesscalableASIC-basedwirespeednetworkmonitoringandaccountingwithnoimpactonnetworkperformance;thisallowsnetworkoperatorstogatheravarietyofsophisticatednetworkstatisticsandinformationforcapacityplanningandreal-timenetworkmonitoringpurposes
•ManagementVLAN
Segmentstraffictoandfrommanagementinterfaces,includingCLI/telnet,aWebbrowserinterface,andSNMP
•Remoteintelligentmirroring
Mirrorsingress/egressACL-selectedtrafficfromaswitchportorVLANtoalocalorremoteswitchportanywhereonthenetwork
•DeviceLinkDetectionProtocol(DLDP)
Monitorsacablebetweentwoswitchesandshutsdowntheportsonbothendsifthecableisbroken,whichpreventsnetworkproblemssuchasloops
•IPv6management
Providesfuture-proofnetworkingbecausetheswitchiscapableofbeingmanagedwhethertheattachednetworkisrunningIPv4orIPv6;supportspingv6,tracertv6,Telnetv6,TFTPv6,DNSv6,syslogv6,FTPv6,SNMPv6,DHCPv6,andRADIUSforIPv6
•Troubleshooting
Ingressandegressportmonitoringenablesnetworkproblem-solving;virtualcabletestsprovidevisibilityintocableproblems
•HPIntelligentManagementCenter(IMC)
Integratesfaultmanagement,elementconfiguration,andnetworkmonitoringfromacentralvantagepoint;built-insupportforthird-partydevicesenablesnetworkadministratorstocentrallymanageallnetworkelementswithavarietyofautomatedtasks,includingdiscovery,categorization,baselineconfigurations,andsoftwareimages;thesoftwarealsoprovidesconfigurationcomparisontools,versiontracking,changealerts,andmore
•Networkmanagement
OffersSNMPv1/2/3,MIB-IIwithTraps,andRADIUSAuthenticationClientMIB(RFC2618);embeddedHTMLmanagementtoolwithsecureaccess
Datasheet|HP5130EIBrazilSwitchSeries
4
Connectivity•Auto-MDIX
Adjustsautomaticallyforstraight-throughorcrossovercablesonall10/100/1000ports
•Flowcontrol
ProvidesbackpressureusingstandardIEEE802.3x,reducingcongestioninheavytrafficsituations
•High-densityconnectivity
Providesupto48fixed10/100/1000BASE-TportsinaLayer2/Layer3switch
•IEEE802.3atPoweroverEthernet(PoE+)support
Simplifiesdeploymentanddramaticallyreducesinstallationcostsbyhelpingtoeliminatethetimeandcostinvolvedinsupplyinglocalpowerateachaccesspointlocation
•Ethernetoperations,administrationandmaintenance(OAM)
Detectsdatalinklayerproblemsthatoccurredinthe“lastmile”usingtheIEEE802.3ahOAMstandard;monitorsthestatusofthelinkbetweentwodevices
Performance•Nonblockingarchitecture
Upto176Gbpsnonblockingswitchingfabricprovideswirespeedswitchingwithupto130.9millionppsthroughput
•Hardware-basedwirespeedaccesscontrollists(ACLs)
Helpsprovidehighlevelsofsecurityandeaseofadministrationwithoutimpactingnetworkperformancewithafeature-richTCAM-basedACLimplementation
Resiliency and high availability•Separatedataandcontrolpaths
Separatescontrolfromservicesandkeepsserviceprocessingisolated;increasessecurityandperformance
•Externalredundantpowersupply
Provideshighreliability
•SmartLink
Allowsunder100msfailoverbetweenlinks
•SpanningTree/PVST+,MSTP,RSTP
Providesredundantlinkswhilepreventingnetworkloops
•IntelligentResilientFramework(IRF)
Createsvirtualresilientswitchingfabrics,wheretwotonineswitchesperformasasingleL2switchandL3router;switchesdonothavetobeco-locatedandcanbepartofadisaster-recoverysystem;serversorswitchescanbeattachedusingstandardLACPforautomaticloadbalancingandhighavailability;canreducetheneedforcomplexprotocolslikeSpanningTreeProtocol,Equal-CostMultipath(ECMP),orVRRP,therebysimplifyingnetworkoperation
Datasheet|HP5130EIBrazilSwitchSeries
5
Layer 2 switching•16KMACaddresstable
ProvidesaccesstomanyLayer2devices
•VLANsupportandtagging
SupportsIEEE802.1Qwith4,094simultaneousVLANIDs
•IEEE802.1adQinQandselectiveQinQ
IncreasesthescalabilityofanEthernetnetworkbyprovidingahierarchicalstructure;connectsmultipleLANsonahigh-speedcampusormetronetwork
•10GbEportaggregation
Allowsgroupingofportstoincreaseoveralldatathroughputtoaremotedevice
•DeviceLinkDetectionProtocol(DLDP)
Monitorslinkconnectivityandshutsdownportsatbothendsifunidirectionaltrafficisdetected,whichpreventsloopsinSTP-basednetworks
•Jumboframesupport
Improvestheperformanceoflargedatatransfers;supportsframesizeofupto9K-byte
Layer 3 services•AddressResolutionProtocol(ARP)
DeterminestheMACaddressofanotherIPhostinthesamesubnet;supportsstaticARPs;gratuitousARPallowsdetectionofduplicateIPaddresses;proxyARPallowsnormalARPoperationbetweensubnetsorwhensubnetsareseparatedbyaLayer2network
•DynamicHostConfigurationProtocol(DHCP)
SimplifiesthemanagementoflargeIPnetworks;supportsclient;DHCPRelayenablesDHCPoperationacrosssubnets
•Loopbackinterfaceaddress
Definesanaddressthatcanalwaysbereachable,improvingdiagnosticcapability
•UserDatagramProtocol(UDP)helperfunction
AllowsUDPbroadcaststobedirectedacrossrouterinterfacestospecificIPunicastorsubnetbroadcastaddressesandpreventsserverspoofingforUDPservicessuchasDHCP
•Routemaps
Providesmorecontrolduringrouteredistribution;allowsfilteringandalteringofroutemetrics
Layer 3 routing•StaticIProuting
ProvidesmanuallyconfiguredroutingforbothIPv4andIPv6networks
•RoutingInformationProtocol(RIP)
UsesadistancevectoralgorithmwithUDPpacketsforroutedetermination;supportsRIPv1andRIPv2routing;includesloopprotection
Datasheet|HP5130EIBrazilSwitchSeries
6
Security•Accesscontrollists(ACLs)
ProvidesIPLayer2toLayer4trafficfiltering;supportsglobalACL,VLANACL,portACL,andIPv6ACL
•IEEE802.1X
Offersindustry-standardmethodofuserauthenticationusinganIEEE802.1XsupplicantontheclientinconjunctionwithaRADIUSserver
•MAC-basedauthentication
Facilitatesclientauthenticationbasedonit’sMACaddress
•Identity-drivensecurityandaccesscontrol
– Per-userACLs
Permitsordeniesuseraccesstospecificnetworkresourcesbasedonuseridentityandtimeofday,allowingmultipletypesofusersonthesamenetworktoaccessspecificnetworkserviceswithoutriskingnetworksecurityorprovidingunauthorizedaccesstosensitivedata
– AutomaticVLANassignment
AutomaticallyassignsuserstotheappropriateVLANbasedontheiridentities
•Securemanagementaccess
Deliverssecureencryptionofallaccessmethods(CLI,GUI,orMIB)throughSSHv2,SSL,and/orSNMPv3
•SecureFTP
Allowssecurefiletransfertoandfromtheswitch;protectsagainstunwantedfiledownloadsorunauthorizedcopyingofaswitchconfigurationfile
•GuestVLAN
Providesabrowser-basedenvironmenttoauthenticatedclientsthatissimilartoIEEE802.1X
•Portsecurity
AllowsaccessonlytospecifiedMACaddresses,whichcanbelearnedorspecifiedbytheadministrator
•Portisolation
Securesandaddsprivacy,andpreventsmaliciousattackersfromobtaininguserinformation
•STPBPDUportprotection
BlocksBridgeProtocolDataUnits(BPDUs)onportsthatdonotrequireBPDUs,preventingforgedBPDUattacks
•STProotguard
Protectstherootbridgefrommaliciousattacksorconfigurationmistakes
Datasheet|HP5130EIBrazilSwitchSeries
7
•DHCPprotection
BlocksDHCPpacketsfromunauthorizedDHCPservers,preventingdenial-of-serviceattacks
•IPsourceguard
HelpspreventIPspoofingattacks
•DynamicARPprotection
BlocksARPbroadcastsfromunauthorizedhosts,preventingeavesdroppingortheftofnetworkdata
•RADIUS/HWTACACS
Easesswitchmanagementsecurityadministrationbyusingapasswordauthenticationserver
Convergence•IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)
FacilitateseasymappingusingnetworkmanagementapplicationswithLLDPautomateddevicediscoveryprotocol
•LLDP-MED
Isastandardextensionthatautomaticallyconfiguresnetworkdevices,includingLLDP-capableIPphones
•LLDP-CDPcompatibility
ReceivesandrecognizesCDPpacketsfromCisco’sIPphonesforseamlessinteroperation
•IEEE802.3afPoweroverEthernet
Providesupto15.4WperporttoPoE-powereddevicessuchasIPphones,wirelessaccesspoints,andvideocameras
•PoEallocations
Supportsmultiplemethods(automatic,IEEE802.3afclass,LLDP-MED,oruser-specified)toallocatePoEpowerformoreefficientenergysavings
•VoiceVLAN
AutomaticallyassignsVLANandpriorityforIPphones,simplifyingnetworkconfigurationandmaintenance
•IPmulticastsnooping(data-drivenIGMP)
PreventsfloodingofIPmulticasttraffic
Device support•PrestandardPoESupport
DetectsandprovidespowertoprestandardPoEdevicessuchaswirelessLANaccesspointsandIPphones
Datasheet|HP5130EIBrazilSwitchSeries
8
Additional information•GreenITandpower
Improvesenergyefficiencythroughtheuseofthelatestadvancesinsilicondevelopment;shutsoffunusedportsandutilizesvariable-speedfans,reducingenergycosts
•Greeninitiativesupport
ProvidessupportforRoHSandWEEEregulations
•UnifiedHPComwareoperatingsystemwithmodulararchitecture
Providesaneasy-to-enhance-and-extendfeatureset,whichdoesn’trequirewhole-scalechanges;allswitching,routing,andsecurityplatformsleveragetheComwareOS,acommonunifiedmodularoperatingsystem
•EnergyEfficientEthernet(EEE)Support
ReducespowerconsumptioninaccordancewithIEEE802.3az
Warranty and support•LimitedLifetimeWarranty2.0
Advancehardwarereplacementwithnext-business-daydelivery(availableinmostcountries).Seehp.com/networking/warrantysummaryfordurationdetails.
•Electronicandtelephonesupport(forLimitedLifetimeWarranty2.0)
limited24x7telephonesupportisavailablefromHPforthefirst3years;limitedelectronicandbusinesshourstelephonesupportisavailablefromHPfortheentirewarrantyperiod;toreachoursupportcenters,refertohp.com/networking/contact-support;fordetailsonthedurationofsupportprovidedwithyourproductpurchase,refertohp.com/networking/warrantysummary
•Softwarereleases
Tofindsoftwareforyourproduct,refertohp.com/networking/support;fordetailsonthesoftwarereleasesavailablewithyourproductpurchase,refertohp.com/networking/warrantysummary
Datasheet|HP5130EIBrazilSwitchSeries
9
HP 5130 EI Brazil Switch Series
Specifications
HP 5130-24G-4SFP+ EI Brazil Switch (JG975A) HP 5130-48G-4SFP+ EI Brazil Switch (JG976A)
I/O ports and slots 24RJ-45autosensing10/100/1000ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly
4SFP+fixed1000/10000SFP+ports
48RJ-45autosensing10/100/1000ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly
4SFP+fixed1000/10000SFP+ports
Additional ports and slots 1RJ-45serialconsoleport 1RJ-45serialconsoleport
Physical characteristicsDimensions
Weight
17.32(w)x6.3(d)x1.72(h)in(44x16x4.36cm)(1Uheight)11.02lb(5kg)
17.32(w)x10.24(d)x1.72(h)in(44x26x4.36cm)(1Uheight)11.02lb(5kg)
Memory and processor 1GBSDRAM,512MBflash;packetbuffersize:1.5MB 1GBSDRAM,512MBflash;packetbuffersize:3MB
Mounting and enclosure MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded)
MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded)
Performance1000MbLatency10GbpsLatencyThroughputRouting/SwitchingcapacityRoutingtablesizeMACaddresstablesize
<5µs<1.5µs96Mpps128Gbps512entries(IPv4),256entries(IPv6)16384entries
<5µs<1.5µs130.9Mpps176Gbps512entries(IPv4),256entries(IPv6)16384entries
ReliabilityMTBF(years) 98.1 61.4
EnvironmentOperatingtemperatureOperatingrelativehumidityNonoperating/StoragetemperatureNonoperating/StoragerelativehumidityAcoustic
32°Fto113°F(0°Cto45°C)10%to90%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensingHigh-speedfan:39.7dB;ISO7779
32°Fto113°F(0°Cto45°C)10%to90%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensingLow-speedfan:43.1dB,High-speedfan:53.4dB;ISO7779
Datasheet|HP5130EIBrazilSwitchSeries
10
Electrical characteristicsFrequencyMaximumheatdissipation
ACvoltageDCvoltageCurrentMaximumpowerratingIdlepower
50/60Hz64/88BTU/hr(67.52/92.84kJ/hr)
100-240VAC
2A26W19W
NotesIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
50/60Hz130/153BTU/hr(137.15/161.42kJ/hr),ForACpoweredunits.ForDCpoweredunitsheatdissipationis130BTU/hrmin,171BTU/hrmax100-240VAC-48to-60VDC10A45W38W
Idlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.PowerratingsforACpowerindicatedabove.Currentusedis5AMaxwhenDCPowerused.ForDCinputpower,idlepoweris38W,maximumDCpowerusedis50W.
Safety UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;ROHSCompliance
UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;ROHSCompliance
Emissions EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;EN61000-4-11:2004;ANSIC63.4-2009;EN61000-3-3:2008;VCCIV-4/2012.04;EN6100-3-2:2006+A1:2009+A2:2009;EN61000-3-2:2006+A1:2009+A2:2009;EN61000-4-3:2006;EN61000-4-4:2012;EN61000-4-5:2006;EN61000-4-6:2009;AS/NZSCISPR22:2009ClassA;CISPR22:2008ClassA;EN55022:2010ClassA;EN61000-4-29:2000;CISPR24:2010;EN300386V1.6.1;VCCIV-3/2013.04ClassA
EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;EN61000-4-11:2004;ANSIC63.4-2009;EN61000-3-3:2008;VCCIV-4/2012.04;EN6100-3-2:2006+A1:2009+A2:2009;EN61000-3-2:2006+A1:2009+A2:2009;EN61000-4-3:2006;EN61000-4-4:2012;EN61000-4-5:2006;EN61000-4-6:2009;AS/NZSCISPR22:2009ClassA;CISPR22:2008ClassA;EN55022:2010ClassA;EN61000-4-29:2000;CISPR24:2010;EN300386V1.6.1;VCCIV-3/2013.04ClassA
Immunity GenericESD
EN55024EN300386
EN55024EN300386
Management IMC—IntelligentManagementCenter;command-lineinterface;Webbrowser;SNMPManager
IMC—IntelligentManagementCenter;command-lineinterface;Webbrowser;SNMPManager
Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.
RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.
Datasheet|HP5130EIBrazilSwitchSeries
11
HP 5130 EI Brazil Switch Series
Specifications (continued)
HP 5130-24G-PoE+-4SFP+ (370W) EI Brazil Switch (JG977A)
HP 5130-48G-PoE+-4SFP+ (370W) EI Brazil Switch (JG978A)
I/O ports and slots 24RJ-45autosensing10/100/1000ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly
4SFP+fixed1000/10000SFP+ports
48RJ-45autosensing10/100/1000ports(IEEE802.3Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-TX:halforfull;1000BASE-T:fullonly
4SFP+fixed1000/10000SFP+ports
Additional ports and slots 1RJ-45serialconsoleport 1RJ-45serialconsoleport
Physical characteristicsDimensions
Weight
17.32(w)x6.3(d)x1.72(h)in(44x16x4.36cm)(1Uheight)11.02lb(5kg)
17.32(w)x10.24(d)x1.72(h)in(44x26x4.36cm)(1Uheight)11.02lb(5kg)
Memory and processor 1GBSDRAM,512MBflash;packetbuffersize:1.5MB 1GBSDRAM,512MBflash;packetbuffersize:3MB
Mounting and enclosure MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded)
MountsinanEIAstandard19-inchtelcorackorequipmentcabinet(hardwareincluded)
Performance1000MbLatency10GbpsLatencyThroughputRouting/SwitchingcapacityRoutingtablesizeMACaddresstablesize
<5µs<1.5µs96Mpps128Gbps512entries(IPv4),256entries(IPv6)16384entries
<5µs<1.5µs130.9Mpps176Gbps512entries(IPv4),256entries(IPv6)16384entries
ReliabilityMTBF(years) 48.3 37.1
EnvironmentOperatingtemperatureOperatingrelativehumidityNonoperating/StoragetemperatureNonoperating/StoragerelativehumidityAcoustic
32°Fto113°F(0°Cto45°C)10%to90%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensingLow-speedfan:49.8dB,High-speedfan:52.9dB;ISO7779
32°Fto113°F(0°Cto45°C)10%to90%,noncondensing-40°Fto158°F(-40°Cto70°C)5%to95%,noncondensingLow-speedfan:50.6dB,High-speedfan:54.6dB;ISO7779
Datasheet|HP5130EIBrazilSwitchSeries
12
Electrical characteristicsFrequencyMaximumheatdissipation
ACvoltageCurrentMaximumpowerratingIdlepowerPoEpower
50/60Hz102/1569BTU/hr(107.61/1655.29kJ/hr),forACPower.ForDCPowerminheatdissipationis85BTU/hrandmaxheatdissipationis2559BTU/hr100-240VAC10A460W
370WPoE+
NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.PoEPoweristhepowersuppliedbytheinternalpowersupply.WhensupplementedwiththeuseofanHPRPS1600RedundantPowerSystem,upto740WofPoE+canbesupplied.MaxcurrentratingforDCpoweris25A.ACInputpoweris30Wtypical,and460Wmax(including370WPoE+consumption.DCInputvoltagerangeis-54to-57VDC.TotalDCinputpoweris25WTypicaland790Wwith740WPoE+Powerconsumption.DCInputvoltagerangeis-54VDCto-57VDC.DCInputSourceistheHPRPS1600.
50/60Hz160/1671BTU/hr(168.8/1762.91kJ/hr),forACpower.ForDCpowerminheatdissipationis147BTU/hrand3037BTU/hrmax.100-240VAC10A490W47W370WPoE+
Idlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.PoEPoweristhepowersuppliedbytheinternalpowersupply.WhensupplementedwiththeuseofanHPRPS1600RedundantPowerSystem,upto740WofPoE+canbesupplied.MaxcurrentratingforDCpoweris25A.ACInputpoweris47Wtypical,and490Wmax(including370WPoE+consumption.DCInputvoltagerangeis-54to-57VDC.TotalDCinputpoweris43Wtypicaland890Wwith800WPoE+Powerconsumption.DCInputvoltagerangeis-54VDCto-57VDC.DCInputSourceistheHPRPS1600.
Safety UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;ROHSCompliance
UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;ROHSCompliance
Emissions EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;EN61000-4-11:2004;ANSIC63.4-2009;EN61000-3-3:2008;VCCIV-4/2012.04;EN6100-3-2:2006+A1:2009+A2:2009;EN61000-3-2:2006+A1:2009+A2:2009;EN61000-4-3:2006;EN61000-4-4:2012;EN61000-4-5:2006;EN61000-4-6:2009;AS/NZSCISPR22:2009ClassA;CISPR22:2008ClassA;EN55022:2010ClassA;EN61000-4-29:2000;CISPR24:2010;EN300386V1.6.1;VCCIV-3/2013.04ClassA
EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;EN61000-4-11:2004;ANSIC63.4-2009;EN61000-3-3:2008;VCCIV-4/2012.04;EN6100-3-2:2006+A1:2009+A2:2009;EN61000-3-2:2006+A1:2009+A2:2009;EN61000-4-3:2006;EN61000-4-4:2012;EN61000-4-5:2006;EN61000-4-6:2009;AS/NZSCISPR22:2009ClassA;CISPR22:2008ClassA;EN55022:2010ClassA;EN61000-4-29:2000;CISPR24:2010;EN300386V1.6.1;VCCIV-3/2013.04ClassA
Immunity GenericESD
EN55024EN300386
EN55024EN300386
Management IMC—IntelligentManagementCenter;command-lineinterface;Webbrowser;SNMPManager
IMC—IntelligentManagementCenter;command-lineinterface;Webbrowser;SNMPManager
Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.
RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.
Datasheet|HP5130EIBrazilSwitchSeries
13
Datasheet|HP5130EIBrazilSwitchSeries
Standards and Protocols(appliestoallproductsinseries)
Device management RFC1157SNMPv1/v2cRFC1305NTPv3RFC2573(SNMPv3Applications)
RFC2819(RMONgroupsAlarm,Event,HistoryandStatisticsonly)RFC3416(SNMPProtocolOperationsv2)HTMLandtelnetmanagement
MultipleConfigurationFilesSNMPv3andRMONRFCsupportSSHv1/SSHv2SecureShellTACACS/TACACS+WebUI
General protocols IEEE802.1adQ-in-QIEEE802.1DMACBridgesIEEE802.1pPriorityIEEE802.1QVLANsIEEE802.1sMultipleSpanningTreesIEEE802.1wRapidReconfigurationofSpanningTreeIEEE802.1XPAEIEEE802.3Type10BASE-TIEEE802.3ab1000BASE-TIEEE802.3adLinkAggregationControlProtocol(LACP)IEEE802.3ae10-GigabitEthernetIEEE802.3afPoweroverEthernetIEEE802.3i10BASE-TIEEE802.3u100BASE-XIEEE802.3xFlowControlIEEE802.3z1000BASE-XRFC768UDPRFC783TFTPProtocol(revision2)RFC791IP
RFC792ICMPRFC793TCPRFC826ARPRFC854TELNETRFC951BOOTPRFC1213ManagementInformationBaseforNetworkManagementofTCP/IP-basedinternetsRFC1305NTPv3RFC1350TFTPProtocol(revision2)RFC1519CIDRRFC1812IPv4RoutingRFC1866HypertextMarkupLanguage-2.0RFC2131DHCPRFC2236IGMPSnoopingRFC2616HTTPCompatibilityv1.1RFC2665DefinitionsofManagedObjectsfortheEthernet-likeInterfaceTypes
RFC2668DefinitionsofManagedObjectsforIEEE802.3MediumAttachmentUnits(MAUs)RFC2865RemoteAuthenticationDialInUserService(RADIUS)RFC2866RADIUSAccountingRFC3414User-basedSecurityModel(USM)forversion3oftheSimpleNetworkManagementProtocol(SNMPv3)RFC3415View-basedAccessControlModel(VACM)fortheSimpleNetworkManagementProtocol(SNMP)RFC3418ManagementInformationBase(MIB)fortheSimpleNetworkManagementProtocol(SNMP)RFC3576ExttoRADIUS(CoAonly)RFC4213BasicIPv6TransitionMechanisms802.1r-GARPProprietaryAttributeRegistrationProtocol(GPRP)
IPv6 RFC1981IPv6PathMTUDiscoveryRFC2460IPv6SpecificationRFC2461IPv6NeighborDiscoveryRFC2463ICMPv6RFC2464TransmissionofIPv6overEthernetNetworksRFC3162RADIUSandIPv6
RFC3306Unicast-Prefix-basedIPv6MulticastAddressesRFC3315DHCPv6(clientandrelay)RFC3484DefaultAddressSelectionforIPv6RFC3736StatelessDynamicHostConfigurationProtocol(DHCP)ServiceforIPv6
RFC4291IPVersion6AddressingArchitectureRFC4293MIBforIPRFC4443ICMPv6RFC4861IPv6NeighborDiscoveryRFC4862IPv6StatelessAddressAuto-configuration
MIBs RFC1212ConciseMIBDefinitionsRFC1213MIBIIRFC1493BridgeMIBRFC1757RemoteNetworkMonitoringMIBRFC2096IPForwardingTableMIBRFC2233InterfaceMIBRFC2571SNMPFrameworkMIBRFC2572SNMP-MPDMIB
RFC2573SNMP-NotificationMIBRFC2573SNMP-TargetMIBRFC2574SNMPUSMMIBRFC2618RADIUSAuthenticationClientMIBRFC2620RADIUSAccountingClientMIBRFC2665Ethernet-Like-MIBRFC2668802.3MAUMIBRFC2674802.1pandIEEE802.1QBridgeMIB
RFC2737EntityMIB(Version2)RFC2819RMONMIBRFC2863TheInterfacesGroupMIBRFC2925PingMIBRFC3414SNMP-Userbased-SMMIBRFC3415SNMP-Viewbased-ACMMIBRFC3418MIBforSNMPv3RFC3621PowerEthernetMIB
Network management IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)
RFC2819FourgroupsofRMON:1 (statistics),2(history),3(alarm)and9 (events)
ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)SNMPv1/v2c/v3
Security IEEE802.1XPortBasedNetworkAccess ControlRFC1492TACACS+RFC2138RADIUSAuthentication
RFC2139RADIUSAccountingRFC2865RADIUS(clientonly)RFC2866RADIUSAccounting
SecureSocketsLayer(SSL)SSHv2SecureShell
14
Datasheet|HP5130EIBrazilSwitchSeries
HP 5130 EI Brazil Switch Series accessories
Transceivers HPX110100MSFPLCLH40Transceiver(JD090A)HPX110100MSFPLCLH80Transceiver(JD091A)HPX110100MSFPLCFXTransceiver(JD102B)HPX110100MSFPLCLXTransceiver(JD120B)HPX115100MSFPLCBX10-UTransceiver(JD100A)HPX115100MSFPLCBX10-DTransceiver(JD101A)HPX1251GSFPLCLH401310nmTransceiver(JD061A)HPX1201GSFPLCLH401550nmTransceiver(JD062A)HPX1251GSFPLCLH70Transceiver(JD063B)HPX1201GSFPLCLH100Transceiver(JD103A)HPX1201GSFPLCSXTransceiver(JD118B)HPX1201GSFPLCLXTransceiver(JD119B)HPX1201GSFPLCBX10-UTransceiver(JD098B)HPX1201GSFPLCBX10-DTransceiver(JD099B)HPX1201GSFPRJ45TTransceiver(JD089B)HPX13010GSFP+LCSRTransceiver(JD092B)HPX13010GSFP+LCLRTransceiver(JD094B)HPX24010GSFP+toSFP+0.65mDirectAttachCopperCable(JD095C)HPX24010GSFP+toSFP+1.2mDirectAttachCopperCable(JD096C)HPX24010GSFP+toSFP+3mDirectAttachCopperCable(JD097C)HPX24010GSFP+toSFP+5mDirectAttachCopperCable(JG081C)
Cables HP0.5mMultimodeOM3LC/LCOpticalCable(AJ833A)HP1mMultimodeOM3LC/LCOpticalCable(AJ834A)HP2mMultimodeOM3LC/LCOpticalCable(AJ835A)HP5mMultimodeOM3LC/LCOpticalCable(AJ836A)HP15mMultimodeOM3LC/LCOpticalCable(AJ837A)HP30mMultimodeOM3LC/LCOpticalCable(AJ838A)HP50mMultimodeOM3LC/LCOpticalCable(AJ839A)HPPremierFlexLC/LCMulti-modeOM42fiber1mCable(QK732A)HPPremierFlexLC/LCMulti-modeOM42fiber2mCable(QK733A)HPPremierFlexLC/LCMulti-modeOM42fiber5mCable(QK734A)HPPremierFlexLC/LCMulti-modeOM42fiber15mCable(QK735A)HPPremierFlexLC/LCMulti-modeOM42fiber30mCable(QK736A)HPPremierFlexLC/LCMulti-modeOM42fiber50mCable(QK737A)
15
Datasheet|HP5130EIBrazilSwitchSeries
HP 5130-48G-4SFP+ EI Brazil Switch (JG976A) HPRPS800RedundantPowerSupply(JD183A)HPRPS1600RedundantPowerSystem(JG136A)HPRPS16001600WACPowerSupply(JG137A)HPX290500V1mRPSCable(JD186A)HPX2901000AJD5Non-PoE2mRPSCable(JD188A)
HP 5130-24G-PoE+-4SFP+ (370W) EI Brazil Switch (JG977A)
HPRPS1600RedundantPowerSystem(JG136A)HPRPS16001600WACPowerSupply(JG137A)HPX2901000AJD52mRPSCable(JD187A)
HP 5130-48G-PoE+-4SFP+ (370W) EI Brazil Switch (JG978A)
HPRPS1600RedundantPowerSystem(JG136A)HPRPS16001600WACPowerSupply(JG137A)HPX2901000AJD52mRPSCable(JD187A)
Learn more at hp.com/networking
RatethisdocumentSharewithcolleagues
Sign up for updates hp.com/go/getupdated
©Copyright2014–2015Hewlett-PackardDevelopmentCompany,L.P.Theinformationcontainedhereinissubjecttochangewithoutnotice.TheonlywarrantiesforHPproductsandservicesaresetforthintheexpresswarrantystatementsaccompanyingsuchproductsandservices.Nothinghereinshouldbeconstruedasconstitutinganadditionalwarranty.HPshallnotbeliablefortechnicaloreditorialerrorsoromissionscontainedherein.