4
Title: How to configure Insite PCX UDL “Cloud” Connection Version: v1.0 Date: 03/01/2020 Product: Pyronix Product Page: 1 of 3 © Hangzhou Hikvision Digital Technology Co.,Ltd. All Rights Reserved. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China • Tel: +86-571-8807-5998 • Fax: +1 909-595-0788 E-Mail: [email protected] www.hikvision.com Preparation 1. Pyronix Deltabell-X 2. Pyronix Panel 3. DS-19A series Network Security Control Panel or MBUS Security Control Panel How to Connect Pyronix Deltabell to Panel The Auto-Arm / Disarm feature can only be set up within the Insite software. Provision is made to have Arm / Disarm periods for each day or for set Holidays so that a building can be automatically secured. To enable the Auto-Arm, select the “Add Action” tab and select the day(s). To each day adjust the ‘Arm’ and ‘Disarm’ times as r equired. 1. Within the Engineer Menu: Options UP/ Downloading “OPTIONS UP/ DOWNLOADING” In “Download by” check or change the connection path from RS232 to Cloud. Then scroll through the submenu and check or change the following parameters:- “System ID” – Take a note of the system ID. AAAAAAA ( Remember we do not use 1 or 0 ) “Security” set to “Standard”. “System Password” – Must be Set to allow Cloud UDL connection via the Insite UDL software. Whatever you input here must be set in the panel account details within Insite UDL software. “Poll server?” should be set to “yes”. “UDL password”… We recommend that this is not set for initial connections. “Site Name” … We recommend that this is not set for initial connections. As with UDL password. If you do add it then it must be set up in the panel account within Insite UDL software. “UDL Priority” – Set to low. Select “A” To Exit Engineer to save the changes IMPORTANT Go back into the Engineer menu “DIAGNOSTICS” – “Communications” and press the key twice “App Status” It should state “Polling Cloud” It must state this before trying to connect with Insite Open Insite UDL software.

How to Connect Pyronix Deltabell to Panel

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: How to Connect Pyronix Deltabell to Panel

Title: How to configure Insite PCX UDL “Cloud” Connection Version: v1.0 Date: 03/01/2020 Product: Pyronix Product Page: 1 of 3

© Hangzhou Hikvision Digital Technology Co.,Ltd. All Rights Reserved. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China • Tel: +86-571-8807-5998 • Fax: +1 909-595-0788

E-Mail: [email protected] • www.hikvision.com

Preparation

1. Pyronix Deltabell-X

2. Pyronix Panel

3. DS-19A series Network Security Control Panel or MBUS Security Control Panel

How to Connect Pyronix Deltabell to Panel

The Auto-Arm / Disarm feature can only be set up within the Insite software.

Provision is made to have Arm / Disarm periods for each day or for set Holidays so that a

building can be automatically secured. To enable the Auto-Arm, select the “Add Action” tab

and select the day(s). To each day adjust the ‘Arm’ and ‘Disarm’ times as required.

1. Within the Engineer Menu: Options UP/ Downloading

• “OPTIONS UP/ DOWNLOADING” In “Download by” check or change the connection path from

RS232 to Cloud.

• Then scroll through the submenu and check or change the following parameters:- • “System ID” – Take a note of the system ID. AAAAAAA ( Remember we do not use 1 or 0 )

• “Security” set to “Standard”.

• “System Password” – Must be Set to allow Cloud UDL connection via the Insite UDL software.

Whatever you input here must be set in the panel account details within Insite UDL software.

• “Poll server?” should be set to “yes”.

• “UDL password”… We recommend that this is not set for initial connections. • “Site Name” … We recommend that this is not set for initial connections. As with UDL

password. If you do add it then it must be set up in the panel account within Insite UDL

software.

• “UDL Priority” – Set to low. • Select “A” To Exit Engineer to save the changes

• IMPORTANT – Go back into the Engineer menu – “DIAGNOSTICS” – “Communications”

– and press the key twice – “App Status” It should state “Polling Cloud” It must

state this before trying to connect with Insite Open Insite UDL software.

Page 2: How to Connect Pyronix Deltabell to Panel

Title: How to configure Insite PCX UDL “Cloud” Connection Version: v1.0 Date: 03/01/2020 Product: Pyronix Product Page: 2 of 3

© Hangzhou Hikvision Digital Technology Co.,Ltd. All Rights Reserved. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China • Tel: +86-571-8807-5998 • Fax: +1 909-595-0788

E-Mail: [email protected] • www.hikvision.com

Open “Forced Dial Customer” to create a new panel account

In Dial Mode drop down box select “Cloud”

Enter System ID .

Enter The Panel’s Engineer Code -

Leave Blank Unless Entered In Panel .

Enter An Appropriate Panel Name Into This F ield .

PLEASE NOTE: This is just for identification in the InSite software, nothing more.

Enter System Password Entered In Panel .

Once All The Details Have B een Entered Select Dial.

Page 3: How to Connect Pyronix Deltabell to Panel

Title: How to configure Insite PCX UDL “Cloud” Connection Version: v1.0 Date: 03/01/2020 Product: Pyronix Product Page: 3 of 3

© Hangzhou Hikvision Digital Technology Co.,Ltd. All Rights Reserved. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China • Tel: +86-571-8807-5998 • Fax: +1 909-595-0788

E-Mail: [email protected] • www.hikvision.com

The “Status” box will say connecting and a Blue status bar will gradually populate the area below it.

If connection is successful, the Cloud Icon will become blue, and a dialogue box will appear asking if you would like to

create a customer – click ‘Yes’ to continue.

Once connected its good practice to save panel configuration and then upload changes where necessary.

• Select Tab “Hang Up Call” To Disconnect Panel.

• To connect to the same account again simply select the Tab “Select Customer F6” - See

Screenshots on the following page for guidance.

Page 4: How to Connect Pyronix Deltabell to Panel

Title: How to configure Insite PCX UDL “Cloud” Connection Version: v1.0 Date: 03/01/2020 Product: Pyronix Product Page: 4 of 3

© Hangzhou Hikvision Digital Technology Co.,Ltd. All Rights Reserved. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China • Tel: +86-571-8807-5998 • Fax: +1 909-595-0788

E-Mail: [email protected] • www.hikvision.com

First Choice for Security Professionals HIKVISION Technical Support