Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
HOTLINE® Blood and Fluid Warmer
Temperature management solutions for improved patient outcomes
THE HOTLINE® FLUID WARMER ELIMINATES PATIENT LINE COOL DOWN, WHILE THE RANGER HOTPLATE WARMER DELIVERS TEMPERATURES WELL BELOW 37° C.2
SUPERIOR PERFORMANCE YOU’LL WARM UP TOHOTLINE® BLOOD AND FLUID WARMERS – HELP PREVENT HYPOTHERMIA
Even mild hypothermia can put your general anesthesia patients at risk for potentially costly and catastrophic complications, from delayed wound healing to cardiac arrest. That’s why hospitals use HOTLINE® Blood and Fluid Warmers.
HOTLINE® Blood and Fluid Warmers help keep your patients warmer and your recovery room less crowded. Your patients and hospital can avoid unnecessary complications and may enjoy the benefi ts of cost savings from shorter recovery room stays.
HELPS CREATE RESULTS
• Superior performance results in warmer patients
• May reduce maintenance time for nurses and technicians
• May lower costs for your hospital
HELPS KEEP PATIENTS WARM
• Patented triple lumen tubing maintains a layer of 42° Celsius (C) circulating solution around the IV line
• Keeps blood and fl uids warm between 37-42° C when used according to Instructions for Use
• Helps eliminate patient line cool-down
• Outperforms hotplate technologies in 91% of all surgical procedures1
HELPS REDUCE COSTS
• The HOTLINE® Blood and Fluid Warmer has an annual maintenance protocol versus hotplate warmers, which require maintenance up to 12 times a year
• Requires less priming volume than hotplate warmers providing less dilution of costly medication
EASY TO USE
• Less time to set up than other warmers on the market
• Easy to connect/disconnect from the patient
1.The HOTLINE® Blood and Fluid Warmer outperforms hotplate technologies in procedures that require fl ow rates of 50-2,000 mL/hours. Data on fi le.
2.Thermal photography. No retouching or digital manipulation. Extension added to hotplate warmer to provide equivalent patient line length. Data on fi le.
HOTLINE®
Ranger®
Internal lumen for infused fl uid
External lumens for warming
solution
HOTLINE®- Blood and Fluid Warmers
Normotherm infusions, up to 5 liters/hour
PERFORMANCE
• Triple lumen tubing provides even heating for normothermic fl uid delivery
SAFETY AND EFFICIENCY
• Warming solution temperature is displayed on the screen
• Visual and sound alerts/alarms
EASY TO USE
• Dedicated disposables
• Easy and quick set up
• Annual maintenance
Alerts and alarms
1. Green: Warmer is OK2. Orange: Check disposable
connection3. Orange: Warming solution level
below minimum4. Red: Over-heating of warming
solution (>43°C)Warming solution stops circulating
1
2
3
4
Easy to connect tubing
Alarms and alerts LEDs
Warming solution temperature is displayed on the screen
PRODUCT(S) DESCRIBED MAY NOT BE LICENSED OR AVAILABLE FOR SALE IN CANADA AND OTHER COUNTRIES
Smiths Medical ASD, Inc. 6000 Nathan Lane NorthMinneapolis, MN 55442, USA Tel: 1-614-210-7300Toll-Free USA: 1-800-258-5361
Find your local contact information at: www.smiths-medical.com/customer-support Smiths Medical is part of the global technology business Smiths Group plc. Please see the Instructions for Use/Operator’s Manual for a complete listing of the indications, contraindications, warnings and precautions. Hotline and the Smiths Medical and Level 1 design marks are trademarks of Smith Medical. The symbol ® indicates the trademark is registered in the U.S. Patent and Trademark Offi ce and certain other countries. All other names and marks mentioned are the trademarks or service marks of their respective owners. ©2016 Smiths Medical. All rights reserved. TM194800EN-122016
MPAUCA-1494
For more information visit our website at www.smiths-medical.com
FOR ROUTINE FLOW WARMING, CHOOSE THE BRAND HOSPITALS TRUST: HOTLINE® BLOOD AND FLUID WARMER
HOTLINE® Routine Flow Fluid Warmer Hardware
Product Code Description Units Per Case
HL-90 HOTLINE® Blood and Fluid Warmer, 41°C/105.8°F Set Point 1
HL-90-38 HOTLINE® Blood and Fluid Warmer, 38°C/100.4°F Set Point 1
HL-90-40 HOTLINE® Blood and Fluid Warmer, 40°C/104°F Set Point 1
HL-390 HOTLINE® 3 Blood and Fluid Warmer, 41°C/105.8°F Set Point 1
HL-390-38 HOTLINE® 3 Blood and Fluid Warmer, 38°C/100.4°F Set Point 1
HL-390-40 HOTLINE® 3 Blood and Fluid Warmer, 40°C/104°F Set Point 1
HOTLINE® Routine Flow Fluid Warmer Accessories
Product Code Description Units Per Case
PC-8 T Connector 40
YC-8 Y Connector 40
L-10 Gas Vent 40
8004001 O-Ring Kit 1
8001082 Mixing Bottle 4
HLTA-390 HOTLINE® 3 Temperature Check 1
80-01-042 HOTLINE® Temperature Check 1
7804007 HOTLINE® 3 Warmer Unit Upgrade Kit 1
HOTLINE® Routine Flow Fluid Warmer Disposables
Product Code Description Units Per Case
L-70 Blood and IV Fluid Warming Set with Injection Port 30
L-70NI Blood and IV Fluid Warming Set without Injection Port 30
L-80 Blood and IV Fluid Warming Set with Injection Port and Gas Vent 30
L-370 HOTLINE® 3 Blood and Fluid Warming Set Disposable 20
ORDERING INFORMATION
HOTLINE® Blood and Fluid Warmers help deliver warmer patients, case after case.
We offer a variety of disposables for the HOTLINE® Blood and Fluid warmer.