Horizontal Electric Steam Boilers
Optional Features - Control circuit transformer- Non-fused interlocking disconnect- Shunt trip- Ground fault protection- Progressive element sequencing- Low water level alarm- Building management system interface- Automatic bottom blowdown- Automatic surface blowdown- 24/7 timers- KWH meter- Ammeter- Steam room controls
Standard Package Includes - Heating elements with magnetic contactors- McDonnell & Miller level control- Probe type aux. low water cut-off- Pressure control switch- Pressure limit switch with manual reset- Safety valve- Blowdown valve(s)- Feed water valve(s)
Applications - Humidification of high tech environments such as computer rooms- Humidification of museum spaces- Sterilization in medical or laboratory environments- Manufacturing processes such as packaging and shrink labeling, plating, retreading- Health clubs and steam rooms- Food processing such as bakeries, breweries, shrimp cooking- Dry cleaning and tailoring
Description Durable ASME Code horizontal electricsteam boilers with flange-mounted,incoloy-sheathed heating elements. Eachboiler is completely automatic withoperating controls, water level control,and low water cut-off. All joints and seamsare welded and hydrostatically tested. Constructed of heavy duty steel. Boileris fully insulated with 2” therma-fibre feltand covered with metal jacket for efficientoperation. All boilers assembled in CedarRapids, IA USA.
Incoming Terminal Block
Safety Valve(Not Pictured)
Fuses
Contactors
Auxiliary LowWater Cut-Off(Behind Panel)
Steam Outlet/Lifting Eye(Not Pictured)
PressureGauge
Float ControlBlowdownSight Glass
(Not Pictured)
Primary LowWater Cut-Off& Pump
Pressure Switch(s)
Heating Element
BlowdownValve
480 Volt - Three Phase (115 Volt - 1Ph. Control Circut)
MODEL BOILERH.P.
PRESSUREASME
CODE 4
AMPHEREDRAWTOTAL Quan. Amps. Std. Avail.
METHOD OFCONTROL OPENINGS
&DIMENSION
APPROX.SHIP
WT. LBS.
CONTRACTORSKW
9151824303648607493112130148
BFBFBFBFBFBFBFBFBFBFBFBFBF
91.51.82.43.03.64.86.07.49.313
11.214.8
100100100100100100100100125125125125125
10.8318.0421.6528.8736.0843.3057.7472.1789.01111.86134.72156.37178.02
1111112235666
40404040405040404040404040
1111111112222
22
2 33333
BB�BBBBCCCCDDEEEEFFGGGGGGGG
425425425500500565675675850875875875875
240 Volt - Three Phase (115 Volt - 1Ph. Control Circut)
MODEL BOILERH.P.
PRESSUREASME
CODE 4
AMPHEREDRAWTOTAL Quan. Amps. Std. Avail.
METHOD OFCONTROL OPENINGS
&DIMENSION
APPROX.SHIP
WT. LBS.
CONTRACTORSKW
9151824303648607493112130148
FFFFFFFFFFFFF
91.51.82.43.03.64.86.07.49.313
11.214.8
100100100100100100100100125125125125125
21.6536.0843.3057.7472.1786.60115.47144.34178.02223.72269.43312.73356.03
1111112235666
40404040405040404040404040
1111112222222
22 3
23333333
BB�BBBBCCCCDDEEEEFFGGGGGGGG
425425425500500565675675850875875875875
208 Volt - Three Phase (115 Volt - 1Ph. Control Circut)
MODEL BOILERH.P.
PRESSUREASME
CODE 4
AMPHEREDRAWTOTAL Quan. Amps. Std. Avail.
METHOD OFCONTROL OPENINGS
&DIMENSION
APPROX.SHIP
WT. LBS.
CONTRACTORSKW
9151824303648607493112130148
AFAFAFAFAFAFAFAFAFAFAFAFAF
91.51.82.43.03.64.86.07.49.313
11.214.8
100100100100100100100100125125125125125
24.9841.6449.9666.6283.2799.93
133.23166.54205.40258.14310.88360.84410.81
1112324635666
40505040405040407060607070
1111112222222
22 3
23333333
BB�BBBBCCCCDDEEEEFFGGGGGGGG
425425425500500565675675850875875875875
Dimensions
Footnotes:
BBCCDDEEFFGG
43:38"43"43"59"59"
27"27"29"29"29"29"
26"18"26"18"40"40"
29"29"29"32"32"32"
0"0"0"
18"0"
40"
3/4"1"
1 1/4"1 1/4"1 1/4"
2"
3/4"3/4"3/4"3/4"3/4"3/4"
3/4"3/4"3/4"3/4"1"1"
24 1/4"18 5/8"24 1/4"24 1/4"38 3/8"38 3/8"
20 1/2"20 1/2"20 1/2"20 1/2"20 1/2"20 1/2"
284264345345536536
9.311.014.014.023.023.0
Spec.
LengthOverall
A
Add forElementRemoval
CHeight
ED
SteamOutlet
F
Steam Boiler OpeningsFeedWater
G
Blow-OffValve
H
BaseLength
J
Base Width
K
Steam ReleaseArea
Sq. InchesWater Capacity at
Normal Level-Gallons
WidthOverall
B
1 One pressure switch provides on/off operation. Advise desired operation pressure.2 Two pressure switches used. Each switch controls approximately one half the load and are set at slightly different settings to allow two step operation. Advise desired operation pressure. 3 Sequence control optional. (Add P to model number). Number of steps based on number of contactors. See price sheet for description of sequence control.4 Pressure shown is standard for steam boilers. High pressures is available on special orders. Sizes 60 KW and smaller are built under ASME "Miniature Code" which may exempt them from some local and state regulations. Boilers can be furnished with low pressure controls and trim.
Lattner Boiler Mfg. Co. 1411 9th St. S.W. Box 1527 Cedar Rapids, IA 52406 800-345-1527 • 319-366-0778 • FAX 319-366-0770 http://www.lattner.com • e-mail: [email protected]
Bulletin No. SB-106-11Printed in USA
Lattner Boiler Manufacturing Co.
Specifications subject to change without notice.