Configurable Pressure TransducerModel FP2000
DESCRIPTIONThe FP2000 series is a configurable differential pressure trans-
ducer which allows the customer to select the configuration
which best fits the needs of the application. Choose from mul-
tiple accuracies, outputs, pressure ports, electrical terminations,
and pressure ranges.
The FP2000 is available with gage, absolute, barometric, or
vacuum reference and, best of all, they delivery in two weeks or
less.
FEATURES• mV/V,0Vdcto5Vdc,0Vdcto10Vdc,4mAto20mA
• Gage,absolute,barometric,vacuum
• Differential(wet/wet,wet/dry)
• Intrinsicallysafeoption5
• CEavailable6
FP2000 pressure sensors are custom built from stocked compo-
nents,andmostareshippedin10businessdaysorless.Please
seehttp://sensing.honeywell.com/TMsensor-shipforupdated
listings
Approved Approved ApprovedIntrinsically safe amp
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model FP2000
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Accuracy1 Seeaccuracytable
Output(selectable) mV/V(seeaccuracytable),0Vdcto5Vdc,0Vdcto10Vdc,or4mAto20mA(twowire)
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -40°Cto116°C[-40°Fto240°F]
Temperature, compensated 4°Cto60°C[40°Fto140°F]2
Temperature, error band 2
0.10%accuracy ±0.5%fullscale
0.25%accuracy ±1.0%fullscale
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Excitation(calibration)
Amplified
(4mAto20mA;0Vdcto5Vdc)
9Vdcto28Vdc
Amplified
(0Vdcto10Vdc) 15Vdcto28Vdc
Unamplified(mV/V) 10Vdc
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media3 Gas,liquid
Overload - safe
positive(+)direction 4Xfullscaleor3000psi,whichever is less
negative(-)direction 4Xfullscaleor250psi,whichever is less
Overload - burst
positive(+)direction 3000psi
negative(-)direction 500psi
Pressure port 200%overcapacity
Wetted parts material HaC276&316Lstainlesssteel
TYPICAL SYSTEM DIAGRAM
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell•SensingandControl3
Configurable Pressure Transducer
PRESSURE RANGES AND RANGE CODESpsi Range
codetorr Range
codemBar Range
codekPa Range
codeBar Range
codeinHg
Range code
mmHg
Range code
in H2O
Range code
Gage/Absolute
0.5* AN1* AP2* AR2.5* AS5 AT10 AV15 BJ25 BL30 BM50 BN75 BP100 BR150 CJ200 CL250 CN300 CP400 CQ500 CR600 CS750 CT1000 CV1500 DJ2000 DL2500 DM3000 DN5000 DR6000 DS7500 DT10000 DV
15** HA50** HB135** HC250 HD750 HE1500 HF
35** JA70** JB175** JC350 JD700 JE750 JF1000 JG3500 JH7000 JI10000 JK
2** KA7** KB15** KC35 KD70 KE100 KF200 KG300 KH700 KJ1000 KL1500 KM1700 KN2000 KP3000 KQ5000 KR7000 KS10000 KT15000 KU20000 KV35000 KW50000 KY70000 KZ
0.035** MA0.1** MB0.2 MC0.5 MD1 ME2 MF3.5 NA5 MG7 NB10 MH20 MI30 MJ35 NC50 MK70 ND100 ML135 NE350 NG500 MM700 NH
1** UB2** UD5 UF10 UA15 UC20 UE30 UG50 UI60 UK80 UM100 UP200 UH300 UJ500 UL1000 UN0-32 US16-32 UQ26-32 UR
15** VA50** VB135 VC250 VD750 VE1500 VF
5** WB10** WA20** WC30** WE50** WG100 WI120 WK150 WM200 WP300 WR500 WS
Barometric(Order codeFPB)
0-30 UG16-32 UQ26-32 UR
Vacuum(Order codeFPV)
1 AP5 AT10 AV15 BJ
50 HB135 HC250 HD750 HE
35 JA70 JB175 JC350 JD700 JE750 JF1000 JG
7 KB15 KC35 KD100 KF
0.035 MA0.1 MB0.2 MC0.5 MD1 ME
10 UA20 UE30 UG
15 VA50 VB135 VC250 VD750 VE
10 WA20 WC30 WE50 WG100 WI
Differential(Order codesFDD, FDW)
0.5 AN1 AP2 AR2.5 AS5 AT10 AV15 BJ25 BL30 BM50 BN75 BP100 BR150 CJ200 CL250 CN300 CP400 CQ500 CR600 CS750 CT1000 CV
15 HA50 HB135 HC250 HD750 HE1500 HF
35 JA70 JB175 JC350 JD700 JE750 JF1000 JG3500 JH7000 JI10000 JK
2 KA7 KB15 KC35 KD70 KE100 KF200 KG300 KH700 KJ1000 KL1500 KM1700 KN2000 KP3000 KQ5000 KR7000 KS10000 KT15000 KU20000 KV35000 KW50000 KY
0.035 MA0.1 MB0.2 MC0.5 MD1 ME2 MF3.5 NA5 MG7 NB10 MH20 MI30 MJ35 NC50 MK70 ND
1 UB2 UD5 UF10 UA15 UC20 UE30 UG50 UI60 UK80 UM100 UP200 UH300 UJ500 UL1000 UN0-32 US16-32 UQ26-32 UR
15 VA50 VB135 VC250 VD750 VE1500 VF
5 WB10 WA20 WC30 WE50 WG100 WI120 WK150 WM200 WP300 WR500 WS
*0.5psito2.5psirangesarenotavailableforabsolutepressure**Notavailableinabsolute
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
4Honeywell•SensingandControl
Model FP2000
INTERNAL AMPLIFIERS
Amplifier specifications
Unamplified output: Option 2u
Voltage output: Option 2d
Voltage output: Option 2g
Current two-wire: Option 2p
Output signal Seeaccuracytable 0Vdcto5Vdc 0Vdcto10Vdc 4mAto20mA
Input power (voltage) 10Vdc 9Vdcto28Vdc 15Vdcto28Vdc 9Vdcto32Vdc
Input power (current) 2mA@10Vdc 10mA 15mA 4mAto24mA
Frequency response Naturalfrequency 300Hz 300Hz 300Hz
Power supply rejection N/A 60dB 60dB 60dB
Operating temperature -40°Cto116°C[-40°Fto240°F]
-29°Cto85°C[-20°Fto185°F]
-29°Cto85°C[-20°Fto185°F]
-29°Cto85°C[-20°Fto185°F]
Reverse voltage protection N/A Yes Yes Yes
Short circuit protection N/A Momentary Momentary Yes
Amplifier specifications
Voltage output: Option 2e
Voltage output: Option 2f
Intrinsically safe amp: Option 2n (2N)***
Current two-wire: Option 2y
Output signal 0Vdcto5Vdc 0Vdcto10Vdc 4mAto20mA 4mAto20mA
Input power (voltage) 9Vdcto28Vdc 15Vdcto28Vdc 9Vdcto28Vdc 9Vdcto32Vdc
Input power (current) 10mA 15mA 4mAto24mA 4mAto24mA
Frequency response 2000Hz 2000Hz 2000Hz 2000Hz
Power supply rejection 60dB 60dB 60dB 60dB
Operating temperature -29°Cto85°C[-20°Fto185°F]
-29°Cto85°C[-20°Fto185°F]`
-29°Cto85°C[-20°Fto185°F]
-29°Cto85°C[-20°Fto185°F]
Reverse voltage protection Yes Yes Yes Yes
Short circuit protection Momentary Momentary Yes Yes
ACCURACY
Non-amplifed output @ 10 Vdc excitation
Gage and absolute Vacuum Barometric Differential
0.10%accuracy 50mV4 25mV 40mV 50mV4
0.25%accuracy 100mV 50mV 80mV 100mV
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell•SensingandControl5
Configurable Pressure Transducer
MOUNTING DIMENSIONS
Code 6a: 6-pin, vented, Bendix style
Code 6m: 4-pin, vented, standard DIN (43650)
Code 6n: 4-pin, vented, mini DIN
Code 6q: 4-conductor, vented, integral cable, 1,52 m [5 ft]
Code 6r: 4-conductor, vented, integral cable, conduit fitting 1,52 m [5 ft]
Code 5a1/4-18 NPT female
Code 5b1/4-18 NPT male
Code 5c7/16-20 UNF female
Code 5d7/16-20 UNF male
Code 5fG 1/4 B female
Code 5gG 1/4 B male
Less than 1000 psi
Greater than 1500 psi
Code 5h1/8-27 NPT female
Code 5i1/8-27 NPT male
Code 5pM12-1.5 male
Code 5qM12-1.5 female
Code 5r9/16-18 SAE male
Code 5s9/16-18 SAE female
Less than 1000 psi
Greater than 1500 psi
FPA, FPG, FPB, FPV
FDW FDD
Pressure ports
Electrical termination
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
6Honeywell•SensingandControl
Model FP2000
Unamplified output: Option 2u
Voltage output: Option 2d/2e
Voltage output: Option 2g/2f
Current two-wire: Option 2p/2y
Intrinsically safe amp: Option 2n (2N)***
Bendix PTIH-10-6P (Option 6a)Noshuntcal A (+)Excitation
B (+)ExcitationC (-)ExcitationD (-)ExcitationE (-)OutputF (+)Output
A (+)SupplyB (-)SupplyreturnC (-)Output0Vdcto 5VdcD (+)OutputE NoconnectionF Noconnection
A (+)SupplyB (-)SupplyreturnC (-)Output0Vdcto 10VdcD (+)OutputVdcE NoconnectionF Noconnection
A (+)SupplyB NoconnectionC NoconnectionD (+)Output4mAto 20mAE NoconnectionF Noconnection
A (+)SupplyB NoconnectionC NoconnectionD (+)Output4mAto 20mAE CasegroundF Noconnection
With shunt cal(option3d)
A (+)ExcitationB (-)ExcitationC (+)OutputD (-)OutputE NoconnectionF ShuntCal
A (+)SupplyB (-)SupplyreturnC (-)Output0Vdcto 5VdcD (+)OutputE NoconnectionF Shuntcal
A (+)SupplyB (-)SupplyreturnC (-)Output0Vdcto 10VdcD (+)OutputE NoconnectionF Shuntcal
A (+)SupplyB NoconnectionC NoconnectionD (+)Output4mAto 20mAE NoconnectionF Shuntcal
A (+)SupplyB NoconnectionC NoconnectionD (+)Output4mAto 20mAE NoconnectionF Shuntcal
Std. DIN 43650 (Option 6m)Noshuntcal 1 (+)Excitation
2 (+)Output3 (-)Output4 (-)Excitation
1 (+)Supply2 (+)Output3 Supply/outputcom.GND Noconnect.tocase
1 (+)Supply2 (+)Output3 Supply/outputcom.GND Noconnect.tocase
1 (+)Supply2 (+)Output4mAto 20mA3 NoconnectionGND Noconnection
1 (+)Supply2 (+)Output3 CasegroundGND Noconnection
With shunt cal(option3d)
NotApplicable 1 (+)Supply2 (+)Output3 Supply/outputcom.GND Shuntcal
1 (+)Supply2 (+)Output3 Supply/outputcom.GND Shuntcal
1 (+)Supply2 (+)Output4mAto 20mA3 NoconnectionGND Shuntcal
1 (+)Supply2 (+)Output3 CasegroundGND Shuntcal
Mini DIN 40050 (Option 6n)Noshuntcal 1 (+)Excitation
2 (+)Output3 (-)Output4 (-)Excitation
1 (+)Supply2 (+)Output3 Supply/outputcom.GND Noconnect.tocase
1 (+)Supply2 (+)Output3 Supply/outputcom.GND Noconnect.tocase
1 (+)Supply2 (+)Output4mAto 20mA3 NoconnectionGND Noconnectiontocase
1 (+)Supply2 (+)Output3 CasegroundGND Noconnection
With shunt cal(option3d)
NotApplicable 1 (+)Supply2 (+)Output3 Supply/outputcom.GND Shuntcal
1 (+)Supply2 (+)Output3 Supply/outputcom.GND Shuntcal
1 (+)Supply2 (+)Output4mAto 20mA3 NoconnectionGND Shuntcal
1 (+)Supply2 (+)Output3 CasegroundGND Shuntcal
1.83 m [5 ft] integral cable (Option 6q)Noshuntcal R (+)Excitation
Bl (-)ExcitationG (-)OutputW (+)Output
R (+)SupplyBl (-)SupplyreturnG (-)OutputW (+)Output0Vdcto 5Vdc
R (+)SupplyBl (-)SupplyreturnG (-)OutputW (+)Output0Vdcto 10Vdc
R (+)SupplyBl (+)Output4mAto 20mA
R (+)SupplyBl (+)Output4mAto 20mAW Case ground
With shunt cal(option3d)
NotApplicable R (+)SupplyBl (-)SupplyreturnG ShuntcalW (+)Output0Vdcto 5Vdc
R (+)SupplyBl (-)SupplyreturnG ShuntcalW (+)Output0Vdcto 10Vdc
R (+)SupplyBl (+)Output4mAto 20mAG Shuntcal
R (+)SupplyBl (+)Output4mAto 20mAW Case groundG Shuntcal
Conduit fitting (Option 6r)Noshuntcal R (+)Excitation
Bl (-)ExcitationG (-)OutputW (+)Output
R (+)SupplyBl (-)SupplyreturnG (-)OutputW (+)Output0Vdcto 5Vdc
R (+)SupplyBl (-)SupplyreturnG (-)OutputW (+)Output0Vdcto 10Vdc
R (+)SupplyBl (+)Output4mAto 20mA
R (+)SupplyBl (+)Output4mAto 20mAW Case ground
With shunt cal(option3d)
NotApplicable R (+)SupplyBl (-)SupplyreturnG ShuntcalW (+)Output0Vdcto 5Vdc
R (+)SupplyBl (-)SupplyreturnG ShuntcalW (+)Output0Vdcto 10Vdc
R (+)SupplyBl (+)Output4mAto 20mAG Shuntcal
R (+)SupplyBl (+)Output4mAto 20mAW Case groundG Shuntcal
Note:Forwiringcodes,R=red;Bl=black;W=white;G=green.Colorspecifiescableandletterornumberspecifiesconnection***SeeHoneywell’sWebsiteformostup-to-dateinformationregardingIntrinsicallySafeapprovalsref.#008-0547-00.
WIRING CODES
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell•SensingandControl7
Configurable Pressure TransducerHow to orderThe FP2000 Order Code isaneasywayforyoutoorderexactlywhatyouwantthefactorytobuild.Simplymakeoneselectionineachofthesixrequiredcategories.Chooseaddersandaccessoriesonlyifyourequirethem.ByvisitingourWebsiteatwww.honeywell.com/sensing you can view complete technical specifications for the FP2000, or click to our on-line shopping site and actually place your order.
Step 1
Transducer type Type Codeo Pressure-gage FPGo Pressure-absolute FPAo Differential-wet/wet FDWo Pressure-barometric FPBo Differential-wet/dry FDDo Pressure-vacuum FPV
Unit typeo psi o baro torr o in Hgo mBar o mm Hgo kPa o in H2O
Step 2
Pressure rangeGage,absolute,anddifferential Range code Range codeo 0.5psi AN o 250psi CNo 1psi AP o 300psi CPo 2psi AR o 400psi CQo 2.5psi AS o 500psi CRo 5psi AT o 600psi CSo 10psi AV o 750psi CTo 15psi BJ o 1000psi CVo 25psi BL o 1500psi DJo 30psi BM o 2000psi DLo 50psi BN o 2500psi DMo 75psi BP o 3000psi DNo 100psi BR o 5000psi DRo 150psi CJ o 6000psi DSo 200psi CL o 7500psi DT o 10000psi DV
Barometric Vacuumo 16-32inHga UQ o 1psi APo 26-32inHga UR o 5psi ATo 0-30inHga UG o 10psi AV o 15psi BJ
Accuracy Accuracycodeo 0.10% 1o 0.25% 2
Step 3
Output Basic Ifadding Ifadding output 9dor9f 1y,3d,9e code (<5000psi) or14co mV/V 2u NA 2uo 5Vdc 2d NA 2eo 10Vdc 2g NA 2fo 4mAto20mA 2p 2n(2N) 2y
NOTE:IfanyADDERSarerequired,theoutputcodemustberevised.Seestep4.
Pressure Port Port codeo 1/4-18NPTfemale 5ao 1/4-18NPTmale 5bo 7/16-20UNFfemale 5co 7/16-20UNFmale 5do G1/4Bfemale 5fo G1/4Bmale 5go 1/8-27NPTfemale 5ho 1/8-27NPTmale 5io M12x1.5male 5po M12x1.5female 5qo 9/16-18UNFSAEmale 5ro 9/16-18UNFSAEfemale 5s
Electrical connector Connector codeo BendixPTIH-10-6P 6ao DIN43650 6mo MiniDIN(40050) 6no Integralpolyurethane5ftcable 6qo 1/2x14NPTconduit5ftcableexit 6r
Step 4
Adders Addercodeo Enhancedthermals 1y Gage:0°Fto180°F Absolute:0°Fto180°F Differential:0°Fto180°F Barometric:30°Fto170°F Vacuum:10°Fto170°Fo Shuntcal 3do ISrating 9do CErating 9eo ISandCErating 9fo Zeroandspanadjustments 14c
o mV/V 2uo 5Vdc 2eo 10Vdc 2fo 4mAto20mA(CEonly) 2yo 4mAto20mA(ISonly 2n(2N)o 4mAto20mA(ISandCE) 2n(2N)
NOTE:Ifyouchooseanyadderoutputfromstep4,youmustrevise your output code selection using this output code chart.ISoutputsavailableonlyonrangesupto5000psi.
AccessoriesMatingconnectorsonly Acc.codeo MiniDIN AA161o Bendix AA111
Matingconn.with15ft.cableforBendixconnector(6A) Without With shunt shunt(3d)o mV/V AA113 AA513o 4mAto20mA AA116 AA516o 0to5/0to10Vdc AA117 AA517
Step 5
Example order code FDW 1 CN 2y 5b 6a 1y AA116
Selection Description CodeTransducertype Differentialwet/wet FDWAccuracy 0.10% 1Pressurerange 250psi CNOutput 4mAto20mA 2yPressureport 1/4-18NPTmale 5bElectricaloutputconnections BendixPTIH-10-6P 6aAdders Enhancedtemperaturerange 1yAccessories Matingconnectorwithcable AA116
Theremustbeacodeineachofthesixbasiccodeboxes.Iftherearenoaddersoraccessorieschosen,leavetheboxesblank.
Description Basic code Adder code (see step 4)
Order codeType Accuracy Range Output Pressure Elect.conn. Extended Shuntcal. IS/CErated Pots
Accessorycode
Zeroandspanadjustmentsarelocatedontheside.Seedrawingfordetails.NozeroandspanadjustmentsareavailableonmV/Voutputoption.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008835-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model FP2000 Configurable Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com
WARNINGPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
NOTES1. Accuraciesstatedareexpectedforbest-fitstraightlineforaller-
rors, including linearity, hysteresis, and non-repeatability through zero.
2. For low pressure ranges, temperature effects may vary.3. Thewet/wetdifferentialpressuretransducerhastwoseparate,
weldedHastelloydiaphragms.Inwet/dryunit,thewetport(highport)hasall-weldedstainlesssteelandHastelloyconstruction.Thedryport(lowport)hasnoisolationdiaphragm.
4. Forlowgageanddifferentialpressurerangesat0.10%accuracy,non-amplifiedoutput@10Vdcexcitation=100mV.
5. Rangeuptoandinclude5000psi.6. Notavailablewith6m.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Low Range Wet/Wet Differential Pressure Transducer
Model KZ
DESCRIPTIONThe Model KZ offers an all-welded stainless steel assembly that
eliminates internal “O” ring leaks and material compatibility. The
Model KZ line pressure zero shift specification can be reduced
to less than 0.5 % FS/1000 psi by the use of an internal line
pressure sensor and analog correction circuit. Line pressures
are available up to 5000 psig with safe overload of either side
up to the maximum line rating. The natural resonant frequency is
increased with the Model KZ because of a stiffer pressure sens-
ing element and the all-welded assembly.
A variety of options are available with the Model KZ including
choice of pressure adaptors, pressure ports, internal amplifiers,
and electrical terminations.
FEATURES• 0.25%FSaccuracy
• 0.5psidto30psid
• All-weldeddesign
• mV/V(standard),4mAto20mA,0Vdcto5Vdc,or0Vdc
to10Vdcoutput
• CEapproved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model KZ
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges ±0.5,1,2,5,10,1525,30psid**
Accuracy ±0.25%fullscale
Linearity ±0.15%fullscale(typical)
Hysteresis ±0.10%fullscale(typical)
Non-repeatability ±0.05%fullscale(typical)
Output(standard)0.5psid 1.0mV/V(nominal)
Output(standard)1psidto4psid
1.5mV/V(nominal)
Output(standard)5psidto30psid
2.0mV/V(nominal)
Line pressure 1500 psi
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -1°Cto88°C[30°Fto190°F]
Temperature, compensated -1°Cto54°C[30°Fto130°F]
Temperature, effect, zero ±0.5 % full scale/100 °F
Temperature, effect, span ±0.5 % reading/100 °F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation(calibration) 10Vdc
Excitation(acceptable) Upto10Vdcorac
Insulation resistance 5000mOhm@50Vdcmax.
Bridge resistance 350ohm(nominal)
Shunt calibration data Included
Elec.termination(std) BendixPTIH-10-6Porequivalent
Matingconnector(notincl.) BendixPT06A-10-6Sorequiv.(AA111)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Allfluidandgasescompatiblewith316stainless steel
Overload-safe 1500 psi
Pressure port 1/8-27NPTfemale(2)
Dead volume 0.4cu.in
Wetted parts material 316stainlesssteel
Weight 1.9kg[4.2lb]
Casematerial Stainless steel
OPTIONS CODEMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Pressure ranges (psid)
0.5,1,2,5,10,15,25,30
Temperature compensa-tion
1b.30°Fto130°F1a.60°Fto160°F1d.-20°Fto130°F1c.0°Fto185°F1j.0°Cto50°C
Internal amplifiers
2u.Unamplified,mV/Voutput
2b.4wire±5Vdc2c.0Vdcto5Vdc2j.4mAto20mA
(three-wire)output
2k.4mAto20mA(two-wire)output11
2n.(2N)4mAto20mA(two-wire)intrinsicallysafe11
2t.0Vdcto10Vdc
Internal amp enhance-ments
3a.Input/outputisolation8
3d.Remotebufferedshuntcalibration
Pressure ports5
5h.1/8-27NPTfemale(2)5a.1/4-18NPTfemale5c.7/16-20UNFfemale
Electrical termination
6a.BendixPTIH-10-6P(orequiv.)6pin(max.120°C)
6e.Integralcable:Teflon(-54°Cto245°C)
6f.Integralcable:PVC(-30°Cto70°C)
6g.Integralcable:Neoprene(-20°Cto80°C)1
6h.Integralcable:Silicone(-54°Cto150°C)
6i.Integralunderwatercable(8m[26ft])(max.80°C)1
6j.1/2-14conduitfittingwith1,5m[5ft]of 4conductorPVCcable
6m.DIN436506q.Moldedintegralcable:
Polyurethane1
6t.Integralcablewithheycospringstrainrelief(1.6m[5.2ft])
Shunt calibration
8a.Precisioninternalresistor6
Special calibration
9a.10point(5up/5down) 20%increments@20°C[68°F]
9b.20point(10up/10down) 10%increments@20°C[68°F]
Wetted diaphragm
10a.316stainlesssteel
Bridge type 11a. Square bridge6
11b. Symmetrical bridge6
11c. Square & symmetrical bridge6
Zero and span adjustment
14b.Topaccesstopots7
14a.Noaccesstopots
Increased line pressure
25a.2000psilinepressure25b.3000psilinepressure25c.5000psilinepressure1
Interfaces 53e.Signaturecalibration6
53t.TEDSIEEE1451.4module9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell•SensingandControl3
Low Range Wet/Wet Differential Pressure Transducer
MOUNTING DIMENSIONSTYPICAL SYSTEM DIAGRAM
INTERNAL AMPLIFIERS
Amplifier specifications
Voltage output: Option 2b
Voltage output: Option 2c
Voltage output: Option 2T
Current three-wire: Option 2j
Current two-wire: Option 2k
Intrinsically safe amp: Option 2n (2N)***
Output signal ±5V 0Vto5Vor±5V@ 5 mA
0Vto10Vor±10V@5mA
4mAto20mA 4mAto20mA 4mAto20mA
Input power (voltage)
±15Vor26Vdcto32Vdc
11Vdcto28Vdc 15Vdcto28Vdc 22Vdcto32Vdc 9Vdcto32Vdc 9Vdcto28Vdc
Input power (current)
45mA 40mA 40mA 65mA 4mAto28mA 4mAto24mA
Freq. response (amp)
3000Hz 3000Hz 3000Hz 2500Hz 300Hz 2000Hz
Power supply rejection
60db 60db 60db 60db 60db 60db
Operating temperature
-20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F
Reverse voltageprotection
Yes Yes Yes Yes Yes Yes
Short circuit protection
Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector(std)2
A(+)SupplyB Output commonCSupplyreturnD(+)OutputEShuntcal1FShuntcal2
A(+)SupplyBOutputcommon**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2
A(+)SupplyBOutputcommon**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2
A(+)SupplyBOutputcommon**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2
A(+)SupplyB No connectionCNoconnectionD(+)OutputECasegroundF No connection
A(+)SupplyB No connectionCNoconnectionD(+)OutputECasegroundF No connection
Wiring code: cable2,3,4
R(+)SupplyBl Output commonG Supply returnW(+)OutputB Shunt cal 1BrShuntcal2
R(+)SupplyBlOutputcommon*GSupplyreturn*W(+)OutputB Shunt cal 1BrShuntcal2
R(+)SupplyBlOutputcommon*GSupplyreturn*W(+)OutputB Shunt cal 1BrShuntcal2
R(+)SupplyBlOutputcommon*GSupplyreturn*W(+)OutputB Shunt cal 1BrShuntcal2
R(+)SupplyBl(+)OutputWCaseground
R(+)SupplyBl(+)OutputWCaseground
*Blackandgreenwiresareinternallyconnected.**PinsBandCareinternallyconnected.***SeeHoneywell’sWebsiteforthemostup-to-dateinformationregardingIntrinsicallysafeapprovals,ref#008-0547-00.
50,8
mm
[2
in] m
ax.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008766-1-ENIL50GLOMay2008Copyright©2008HoneywellInternationalInc.Allrightsreserved.
Model KZ Low Range Wet/Wet Differential Pressure Transducer
Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com
WARNINGPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.
•Completeinstallation,operationandmaintenanceinformation is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
NOTES
1. Availability varies according to range.2. Interconnectingshuntcal.1terminalwithshuntcal.2terminal
provides50%(unamplifiedunits),75%(4mAto20mA3-wireunits)or80%(voltageamplifiedunitsoffullscaleoutputforquickcalibration. Shunt calibration comes standard with internal amplifier options2b,2c,2tand2j.
3. O=Orange,Y=Yellow,B=Blue,Bl=Black,R=Red,Br=Brown,W=White,G=Green.Colorspecifyingcableandnumberorletterspecifying connector.
4. Nomatingconnectornecessaryforcableoption.5. Some pressure port options may require axial orientation.6. Onlyavailablewithunamplifiedoption2u.7. Onlyavailablewithamplifiedoptions.8. OnlyavailablewithVdcoutputoptions2b,2c.9. ConsultfactoryforTEDSavailabilitywithamplifiedmodels.10. Terminationdependent;consultfactory.11. 5000 ohm bridge required.
**Option:alsoavailable,equivalentinchesofwatercolumn,inchesofHGcolumn,mBarorkPaforpressureranges
Note:Unlessotherwisespecifiedonorder,amplifiedunitswith4mAto20mAoutputwillprovide4mAat0psidand20mAatpositivefullscaleand the unit will not operate in the negative direction. An available is to specify4mAatnegativefullscaleand20mAatpositivefullscale.Allampsadd2intohousing.
RANGE CODES
Range Code Available rangesAN ±0.5 psid
AP ±1 psid
AR ±2psid
AT ±5 psid
AV ±10 psid
BJ ±15 psid
BL ±25psid
BM ±30psid
Connector Unamplified
A, B (+)excitation
C, D (-)excitation
E (-)output
F (+)output
WIRING CODES
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Mid Range Wet/Wet Differential Pressure Transducer
Model Z
DESCRIPTIONModels Z Mid Range Wet/Wet Differential is high accuracy,
bonded foil strain gage transducers designed to accept fluid in
both ports and measure differential pressure ranges of
50 to 750 psid. Standard features such as overload stops and
stainless steel construction provide unit durability in rugged
industrial environments. Each is bi-directional and achieves
accuracies of .25 % to .5 % full scale. The models are available
with extended temperature ranges. Typical applications include
flow measurement, depth sensing, pressure equalization, and
liquid level.
FEATURES• 50 psid to 750 psid
• 0.25% accuracy
• Amplified output available
• Intrinsically safe available (2N option only)10
• CE approved11
POTENTIAL APPLICATIONS• Flow measurement
• Depth sensing
• Pressure equalization
• Liquid level
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model Z
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges 50, 75, 100, 150, 200, 300, 500, 750 psid
Accuracy ±0.25 % full scale
Linearity ±0.15 % full scale (typical)
Hysteresis ±0.10 % full scale (typical)
Non-repeatability ±0.05 % full scale (typical)
Output (standard) 2 mV/V (nominal)
Line pressure 1500 psi
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]
Temperature, effect, zero ±0.5 % full scale/100 °F
Temperature, effect, span ±0.5 % reading/100 °F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (calibration) 10 Vdc
Excitation (acceptable) Up to 10 Vdc or ac
Insulation resistance 5000 mOhm @ 50 Vdc
Bridge resistance 350 ohm
Shunt calibration data Included
Elec. termination (std) PTIH-10-6P or equivalent (hermetic stainless)
Mating connector (not incl.) PT06A-10-6S or equiv. (AA111)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Gas, liquid
Overload-safe 1500 psi
Pressure port 1/8-27 NPT female (2)
Dead volume 0.25 cu. in
Wetted parts material 17-4 PH stainless steel
Weight 2,3 kg [5 lb]
Case material Stainless steel
OPTION CODES
Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Pressure ranges (psid)
50, 75, 100, 150, 200, 300, 500, 750
Temperaturecompensation
1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F1f. 70 °F to 250 °F
1g. 70 °F to 325 °F1h. 70 °F to 400 °F 1i. -65 °F to 250 °F1j. 0 °C to 50 °C1m. -25 °C to 110 °C
Internal amplifiers
2b. 4 wire ±5 Vdc2c. 0 Vdc to 5 Vdc2j. 4 mA to 20 mA (3-wire) output2k. 4 mA to 20 mA (two-wire) output
2n. (2N) 4 mA to 20 mA (two-wire) intrinsically safe2t. 0 Vdc to 10 Vdc2u. Unamplified, mV/V output
Internal amp enhancements
3a. Input/output isolation8 3d. Remote buffered shunt calibration
Pressure ports5
5h. 1/8-27 NPT female (2)5c. 7/16-20 UNF female
Electricaltermination
6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 250 °F)
6b. MS type connector1
6e. Integral cable: Teflon (-54 °C to 245 °C)
6f. Integral cable: PVC (-30 °C to 70 °C)
6g. Integral cable: Neoprene (-20 °C to 80 °C)1
6h. Integral cable: Silicone (-54 °C to 150 °C)
6i. Integral underwater cable (8m [26 ft]) (max. 80 °C)1
6j. 1/2-14 conduit fitting with 1,5 m [5 ft] of 4 conductor PVC cable
Shunt calibration 8a. Precision internal resistor7
Special calibration
9a. 10 point (5 up/5 down) 20% increments @ 20 °C
9b. 20 point (10 up/10 down) 10% increments @ 20 °C
Wetted diaphragm
17-4 PH Stainless steel10a. 316 stainless steel
Bridge type 11a. Square bridge6
11b. Symmetrical bridge6
11c. Square & symmetrical bridge6
Zero & span adjustment
14a. No access to pots 14b. Top access to pots 6
Interfaces 53e. Signature calibration6
53t. TEDS IEEE 1451.4 module9RANGE CODES
Range Code
Available ranges
RangeCode
Available ranges
BN ±50 psid CL ±200 psid
BP ±75 psid CP ±300 psid
BR ±100 psid CR ±500 psid
CJ ±150 psid CT ±750 psid
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell • Sensing and Control 3
Mid Range Wet/Wet Differential Pressure Transducer
INTERNAL AMPLIFIERS
Amplifier specifications
Voltage output: Option 2b
Voltage output: Option 2c
Voltage output: Option 2t
Current three-wire: Option 2j
Current two-wire: Option 2k
Intrinsically safe amp: Option 2n (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V @ 5 mA
0 V to 10 V or ±10 V @ 5 mA
4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
Input power (voltage) ±15 V or 26 Vdc to 32 Vdc
11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc 9 Vdc to 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db
Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse voltage protection
Yes Yes Yes Yes Yes Yes
Short cir. protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector (std)2
A (+) SupplyB Output commonC Supply returnD (+) OutputE Shunt cal 1
F Shunt cal 2
A (+) SupplyB Output common**C Supply return **D (+) OutputE Shunt cal 1
F Shunt cal 2
A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1
F Shunt cal 2
A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1
F Shunt cal 2
A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection
A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection
Wiring code: cable2,3,4 R (+) SupplyBl Output commonG Supply returnW (+) OutputB Shunt cal 1
Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1
Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1
Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1
Br Shunt cal 2
R (+) SupplyBl (+) OutputW Case ground
R (+) SupplyBl (+) OutputW Case ground
* Black and green wires are internally connected.** Pins B and C are internally connected.*** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals, ref #008-0547-00.
MOUNTING DIMENSIONS AND CHARACTERISTICS
50,8
mm
[2
in] m
ax.
TyPICAL SySTEM DIAGRAMConnector Unamplified
A, B (+) excitation
C, D (-) excitation
E (-) output
F (+) output
WIRING CODES
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008721-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model Z Mid Range Wet/Wet Differential Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINGPERSONAL INJURy• DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION • The information presented in this catalogue is for reference
only. DO NOT USE this document as product installation information.
• Complete installation, operation and maintenance information
is provided in the instructions supplied with each product.Failure to comply with these instructions could result in death or serious injury.
NOTES1. Availability varies according to range.2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal
provides 50% (unamplified units), 75% (4 mA to 20 mA 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with inter-nal amplifier options 2b, 2c, 2t and 2j.)
3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector.
4. No mating connector necessary for cable option.5. Some pressure port options may require axial orientation.6. Only available with unamplified option 2u.7. Only available with amplified options.8. Only available with Vdc output options 2b, 2c.9. Consult factory for TEDS availability with amplified models.10. Range dependent; consult factory. Termination dependent;
consult factory.11. Internal amp and termination dependent; consult factory.12 5000 ohm bridge required.
Note: Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An available is to specify 4 mA at negative full scale and 20 mA at positive alternative/full scale. All amps add 2 in to housing.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Mid Range Wet/Wet Differential Pressure Transducer
Model A-5
FEATURES• 0.5% accuracy
• 50 psid to 750 psid
• mV/V (standard), 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc
to 10 Vdc output
• Intrinsically safe available (2N option only)10
• CE approved11
DESCRIPTIONModel A-5 mid-range Wet/Wet Differential is a bonded foil strain
gage transducers designed to accept fluid in both ports and
measure differential pressure ranges from 50 psid to 750 psid.
Standard features such as overload stops and stainless steel
construction provide unit durability in rugged industrial environ-
ments. Each is bi-directional and achieves accuracies of 0.5 %
full scale.
A variety of standard options are available with the Model A-5 in-
cluding the traditional removable pressure adaptors for cleaning
purposes, extended temperature ranges, alternative pressure
ports, internal amplifiers options, and electrical terminations.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model A-5
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges 50, 75, 100, 150, 200, 300, 500, 750 psid
Accuracy ±0.5 % full scale
Linearity ±0.25 % full scale (typical)
Hysteresis ±0.13 % full scale (typical)
Non-repeatability ±0.07 % full scale (typical)
Output (standard) 2 mV/V (nominal)
Line pressure 1500 psi
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]
Temperature, effect, zero ±0.75 % full scale/100 °F
Temperature, effect, span ±1.0 % reading/100 °F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (calibration) 10 Vdc
Excitation (acceptable) Up to 10 Vdc or ac
Insulation resistance 5000 mOhm @ 50 Vdc
Bridge resistance 350 ohm
Shunt calibration data Included
Elec. termination (std) Bendix PTIH-10-6P or equivalent (hermetic stainless)
Mating connector (not incl.) Bendix PT06A-10-6S or equiv. (AA111)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Gas, liquid
Overload-safe 1500 psi
Pressure port 1/8-27 NPT female (2)
Dead volume 0.25 cu. in
Wetted parts material 17-4 PH stainless steel
Weight 2,3 kg [5 lb]
Case material Stainless steel
OPTION CODES
Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Pressure ranges (psid)
50, 75, 100, 150, 200, 300, 500, 750
Temperature compensation
1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F1f. 70 °F to 250 °F
1j. 0 °C to 50 °C 1i. -65 °F to 250 °F6
1m. -25 °C to 110 °C1g. 70 °F to 325 °F6
1h. 70 °F to 400 °F6
Internal amplifiers
2b. 4 wire ±5 Vdc2c. 0 Vdc to 5 Vdc2j. 4 mA to 20 mA
(3-wire) output2k. 4 mA to 20 mA
(two-wire) output12
2n. (2N) 4 mA to 20 mA (2 wire) intrin-sically safe12
2t. 0 Vdc to 10 Vdc2u. Unamplified, mV/V
output
Internal ampenhancements
3a. Input/output isolation8
3d. Remote buffered shunt calibration
Pressure ports5 5h. 1/8-27 NPT female (2)5c. 7/16 in -20 UNF female (per MS33656E4)
Electrical termination
6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 250 °F)
6b. MS type connector to mate MS3106-14S-6S (max. 160 °F)1
6e. Integral cable: Teflon (-54 °C to 245 °C)
6f. Integral cable: PVC (-30 °C to 70 °C)
6g. Integral cable: Neoprene (-20 °C to 80 °C) 1
6h. Integral cable: Silicone (-54 °C to 150 °C)
6i. Integral underwater cable (8 m [26 ft]) (max. 80°C)1
6j. 1/2-14 conduit fitting with 1,5 m [5 ft] of 4 conductor PVC cable
Shunt calibration
8a. Precision internal resistor 6
Special calibration
9a. 10 point (5 up/5 down) 20% increments @ 20 °C9b. 20 point (10 up/10 down) 10% increments @ 20 °C
Wetted diaphragm
17-4 PH stainless steel10a. 316 stainless steel
Bridge type 11a. Square bridge6
11b. Symmetrical bridge6
11c. Square & symmetrical bridge6
Zero & span adjustment
14a. No access14b. Top access6
O-ring seals 26a. Metal26b. Vi-Ton26c. Teflon
Interfaces 53e. Signature calibration6
53t. TEDS IEEE 1451.4 module9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell • Sensing and Control 3
Mid Range Wet/Wet Differential Pressure Transducer
TYPICAL SYSTEM DIAGRAM
INTERNAL AMPLIFIERS
Amplifier specifications
Voltage output: Option 2b
Voltage output: Option 2c
Voltage output: Option 2t
Current three-wire: Option 2j
Current two-wire: Option 2k
Intrinsically safe amp: Op-tion 2n (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V @ 5 mA
0 V to 10 V or ±10 V @ 5 mA
4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
Input power (voltage) ±15 V or 26 Vdc to 32 Vdc
11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc 9 Vdc to 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rejection 60 db 60 db 60 db 60 db 60 db 60 db
Operating temperature -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse volt. protection Yes Yes Yes Yes Yes Yes
Short circuit protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector (std)2
A (+) SupplyB Output commonC Supply returnD (+) OutputE Shunt cal 1
F Shunt cal 2
A (+) SupplyB Output common**C Supply return **D (+) OutputE Shunt cal 1
F Shunt cal 2
A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1
F Shunt cal 2
A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1
F Shunt cal 2
A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection
A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection
Wiring code: cable2,3,4
R (+) SupplyBl Output commonG Supply returnW (+) OutputB Shunt cal 1
Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1
Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1
Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1
Br Shunt cal 2
R (+) SupplyBl (+) OutputW Case ground
R (+) SupplyBl (+) OutputW Case ground
* Black and green wires are internally connected.** Pins B and C are internally connected.*** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals. Ref #008-0547-00.
MOUNTING DIMENSIONS AND CHARACTERISTICS
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008722-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model A-5 Mid Range Wet/Wet Differential Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINGPERSONAL INJURY
• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.
• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
RANGE CODES
Range Code
Available ranges
RangeCode
Available ranges
BN ±50 psid CL ±200 psid
BP ±75 psid CP ±300 psid
BR ±100 psid CR ±500 psid
CJ ±150 psid CT ±750 psid
NOTES1. Availability varies according to range.2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal
provides 50% (unamplified units), 75% (4 mA to 20 mA 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier options 2b, 2c, 2t and 2j.
3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector.
4. No mating connector necessary for cable option.5. Some pressure port options may require axial orientation.6. Only available with unamplified option 2u.7. Only available with amplified options.8. Only available with Vdc output options 2b, 2c.9. Consult factory for TEDS availability with amplified models.10. Range dependent; consult factory. Termination dependent; consult
factory.11. Internal amp and termination dependent; consult factory.12. 5000 ohm bridge required.
Note: Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An available is to specify 4 mA at negative full scale and 20 mA at positive full scale. All amps add 2 in to housing.
Connector Unamplified
A, B (+) excitation
C, D (-) excitation
E (-) output
F (+) output
WIRING CODES
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
High Range Wet/Wet Differential Pressure Transducer
Model Z
DESCRIPTIONThe Z High Range Wet/Wet transducers are engineered to
measure differential pressures as great as 10k psid and achieve
accuracy of 0.25 % full scale. Each is bi-directional and accepts
fluid in both ports. 17-4 PH stainless steel ensures durability of
these bonded foil strain gage units under harsh industrial condi-
tions.
A variety of standard options are available with the Model Z in-
cluding choice of pressure adaptors, alternative pressure ports,
internal amplifiers options, and electrical terminations.
FEATURES• 0.25% accuracy
• 2000 psid to 10000 psid
• mV/V (standard), 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc
to 10 Vdc output
• Intrinsically safe available (2N option only)10
• CE approved11
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model Z
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges 2000, 3000, 5000, 7500, 10000 psid
Accuracy ±0.25 % full scale
Linearity ±0.15 % full scale (typical)
Hysteresis ±0.10 % full scale (typical)
Non-repeatability ±0.05 % full scale (typical)
Output (standard) 2 mV/V (nominal)
Line pressure 2000 psi
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]
Temperature, effect, zero ±0.5 % full scale/100 °F
Temperature, effect, span ±0.5 % reading/100 °F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (calibration) 10 Vdc
Bridge resistance 350 ohm (nominal)
Shunt calibration data Included
Elec. termination (std) PTIH-10-6P or equivalent (hermetic stainless)
Mating connector (not incl.) PT06A-10-6S or equiv. (AA111)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Gas, liquid
Overload-safe number here
2000 psid to 3000 psid 100% over capacity
5000 psid to 10000 psid 50% over capacity
Pressure port 1/4-18 NPT female (2)
Wetted parts material 17-4 PH stainless steel
Case material Stainless steel
OPTION CODES
Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor- ship for updated listings.
Pressure ranges (psid)
2000, 3000, 5000, 7500, 10000
Temperature compensation
1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F1f. 70 °F to 250 °F
1g. 70 °F to 325 °F6
1h. 70 °F to 400 °F6
1i. -65 °F to 250 °F6
1j. 0 °C to 50 °C1m. -25 °C to 110 °C
Internal amplifiers
2u. Unamplified, mV/V output
2b. 4 wire ±5 Vdc2c. 0 Vdc to 5 Vdc2t. 0 Vdc to 10 Vdc2j. 4 mA to 20 mA
(three-wire) output
2k. 4 mA to 20 mA (two-wire) output12
2n. (2N) 4 mA to 20 mA (two-wire) intrinsically safe12
Pressure ports 5 5a. 1/4-18 NPT female5c. 7/16-20 UNF female
Electrical termination
6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 250 °F)
6b. MS type connec-tor to mate with MS3106-14S-6S (max. 160 °F)1
6e. Integral cable: Teflon (-54 °C to 245 °C)
6f. Integral cable: PVC (-30 °C to 70 °C)
6g. Integral cable: Neoprene (-20 °C to 80 °C)1
6h. Integral cable: Silicone (-54 °C to 150 °C)
6i. Integral underwater cable (8m [26 ft]) (max. 80 °C)1
6j. 1/2-14 conduit fit-ting with 1,5 m [5 ft] of 4 conductor PVC cable
Shunt calibration
8a. Precision internal resistor8
Special calibration
9a. 10 point (5 up/5 down) 20% increments @ 20 °C9b. 20 point (10 up/10 down) 10% increments @ 20 °C
Wetted diaphragm
17-4 PH stainless steel
Bridge type 11a. Square bridge6
11c. Square & symmetrical bridge6
11b. Symmetrical bridge6
Zero and span adjustment
14b. Top access to pots 7
14a. No access to pots
O ring seals 26a. Metal
Interfaces 53e. Signature calibration6
53t. TEDS IEEE 1451.4 module9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell • Sensing and Control 3
High Range Wet/Wet Differential Pressure Transducer
INTERNAL AMPLIFIERS
Amplifier specifications
Voltage output: Option 2b
Voltage output: Option 2c
Voltage output: Option 2t
Current three-wire: Option 2j
Current two-wire: Option 2k
Intrinsically safe amp: Option 2n (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V @ 5 mA
0 V to 10 V or ±10 V @ 5 mA
4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
Input power (voltage) ±15 V or 26 Vdc to 32 Vdc
11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc 9 Vdc to 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db
Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse voltage protection
Yes Yes Yes Yes Yes Yes
Short cir. protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector (std)2
A (+) SupplyB Output commonC Supply returnD (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB Output common**C Supply return **D (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection
A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection
Wiring code: cable2,3,4 R (+) SupplyBl Output commonG Supply returnW (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl (+) OutputW Case ground
R (+) SupplyBl (+) OutputW Case ground
* Black and green wires are internally connected.** Pins B and C are internally connected.
TyPICAL SySTEM DIAgRAM
4-18
MOUNTINg DIMENSIONS AND CHARACTERISTICS
For reference only
2X
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008718-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model Z High Range Wet/Wet Differential Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURy
• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.
• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
RANgE CODES
Range Code Available rangesDL ±2000 psid
DN ±3000 psid
DR ±5000 psid
DT ±7500 psid
DV ±10000 psid
NOTES1. Availability varies according to range.2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal pro-
vides 50% (unamplified units), 75% (4 mA to 20 mA 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier options 2b, 2c, 2t and 2j.
3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector.
4. No mating connector necessary for cable option.5. Some pressure port options may require axial orientation.6. Only available with unamplified option 2u.7. Only available with amplified options.8. Only available with Vdc output options 2b, 2c.9. Consult factory for TEDS availability with amplified models.10. Range dependent; consult factory. Termination dependent; consult
factory.11. Internal amp and termination dependent; consult factory.12. 5000 ohm bridge required.
Note: Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An avail-able alternative is to specify 4 mA at negative full scale and 20 mA at positive full scale. All amps add 2 in to amplifier housing.
Connector Unamplified
A, B (+) excitation
C, D (-) excitation
E (-) output
F (+) output
WIRINg CODES
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
High Range Wet/Wet Differential Pressure Transducer
Model A-5
DESCRIPTIONThe A-5 high range Wet/Wet transducers are engineered to mea-
sure differential pressures as great as 10k psid and achieves
accuracy of 0.5 % full scale. Each series is bi-directional and
accepts fluid in both ports. 17-4 PH stainless steel ensures dura-
bility of these bonded foil strain gage units under harsh industrial
conditions.
A variety of standard options are available with the Model A-5 in-
cluding choice of pressure adaptors, alternative pressure ports,
internal amplifiers options, and electrical terminations.
FEATURES• 0.5% accuracy
• 2000 psid to 10000 psid
• mV/V (standard), 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc
to 10 Vdc output
• Intrinsically safe available (2N option only)10
• CE approved11
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model A-5
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges 2000, 3000, 5000, 7500, 10000 psid
Accuracy ±0.5 % full scale
Linearity ±0.25 % full scale (typical)
Hysteresis ±0.13 % full scale (typical)
Non-repeatability ±0.07 % full scale (typical)
Output (standard) 2 mV/V (nominal)
Line pressure 2000 psi
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]
Temperature, effect, zero ±0.75 % full scale/100 °F
Temperature, effect, span ±1.0 % reading/100 °F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (calibration) 10 Vdc
Bridge resistance 350 ohm (nominal)
Shunt calibration data Included
Elec. termination (std) PTIH-10-6P or equivalent (hermetic stainless)
Mating connector (not incl.) PT06A-10-6S or equiv. (AA111)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Gas, liquid
Overload-safe2000 psid to 3000 psid
100% over capacity
Overload-safe5000 psid to 10000 psid
50% over capacity
Pressure port 1/4-18 NPT female (2)
Wetted parts material 17-4 PH stainless steel
Case material Stainless steel
OPTION CODES
Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Pressure ranges (psid)
2000, 3000, 5000, 7500, 10000
Temperature compensation
1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F1f. 70 °F to 250 °F
1i. -65 °F to 250 °F1j. 0 °C to 50 °C1m. -25 °C to 110 °C 1g. 70 °F to 325 °F1h. 70 °F to 400 °F
Internal amplifiers
2u. Unamplified, mV/V output2b. 4 wire ±5 Vdc2c. 0 Vdc to 5 Vdc2j. 4 mA to 20 mA (3-wire) output
2k. 4 mA to 20 mA (two-wire) output12
2n. (2N) 4 mA to 20 mA (two-wire) intrinsically safe12
2t. 0 Vdc to 10 Vdc
Internal amp enhancements
3a. Input/output isolation6 3d. Remote buffered shunt calibration
Pressure ports5 5a. 1/4-18 NPT female5c. 7/16-20 UNF female
Electrical termination
6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 120 °C)
6b. MS type connec-tor 1
6e. Integral cable: Teflon (-54 °C to 245 °C)
6f. Integral cable: PVC (-30 °C to 70 °C)
6g. Integral cable: Neoprene (-20 °C to 80 °C)1
6h. Integral cable: Silicone (-54 °C to 150 °C)
6i. Integral underwater cable (8m [26 ft]) (max. 80°C)1
6j. 1/2-14 conduit fit-ting with 1,5 m [5 ft] of 4 conductor PVC cable
Shunt calibration 8a. Precision internal resistor7
Special calibration
9a. 10 point (5 up/5 down) 20% increments @ 20 °C9b. 20 point (10 up/10 down) 10% increments @ 20 °C
Wetted diaphragm
17-4 PH stainless steel
Bridge type 11a. Square bridge11c. Square & symmetrical bridge11b. Symmetrical bridge
Zero and span adjustment
14b. Top access to pots8
14a. No access to pots
O ring seals 26a. Metal
Interfaces53e. Signature calibration53t. TEDS IEEE 1451.4 module9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell • Sensing and Control 3
High Range Wet/Wet Differential Pressure Transducer
INTERNAL AMPLIFIERS
Amplifier specifications
Voltage out-put: Option 2b
Voltage out-put: Option 2c
Voltage out-put: Option 2t
Current three-wire: Option 2j
Current two-wire: Option 2k
Intrinsically safe amp: Op-tion 2n (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V @ 5 mA
0 V to 10 V or ±10 V @ 5 mA
4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
Input power (voltage) ±15 V or 26 Vdc to 32 Vdc
11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc
9 Vdc to 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. response (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rejection 60 db 60 db 60 db 60 db 60 db 60 db
Operating temperature -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse volt. protection Yes Yes Yes Yes Yes Yes
Short circuit protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector (std)2
A (+) SupplyB Output commonC Supply returnD (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB Output common**C Supply return **D (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection
A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection
Wiring code: cable2,3,4 R (+) SupplyBl Output commonG Supply returnW (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl (+) OutputW Case ground
R (+) SupplyBl (+) OutputW Case ground
* Black and green wires are internally connected.** Pins B and C are internally connected.*** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals, ref #008-0547-00.
TyPICAL SySTEM DIAgRAM
MOUNTINg DIMENSIONS AND CHARACTERISTICS
For reference onlyNOT TO SCALE
1/4-18 NPT female
2X
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008719-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model A-5 High Range Wet/Wet Differential Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURy
• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.
• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
RANgE CODES
Range Code Available ranges
DL ±2000 psid
DN ±3000 psid
DR ±5000 psid
DT ±7500 psid
DV ±10000 psid
NOTES1. Availability varies according to range.2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal pro-
vides 50% (unamplified units), 75% (4 mA to 20 mA 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier options 2b, 2c, 2t and 2j.)
3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector.
4. No mating connector necessary for cable option.5. Some pressure port options may require axial orientation.6. Only available with unamplified option 2u.7. Only available with amplified options.8. Only available with Vdc output options 2b, 2c.9. Consult factory for TEDS availability with amplified models.10. Range dependent; consult factory. Termination dependent; consult
factory.11. Internal amp and termination dependent; consult factory.12. 5000 ohm bridge required.
Note: Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An available alternative is to specify 4 mA at negative full scale and 20 mA at positive full scale. All amps add 2 in to amplifier housing.
Connector Unamplified
A, B (+) excitation
C, D (-) excitation
E (-) output
F (+) output
WIRINg CODES
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
DP Low Range Two Wire Wet/Wet Differential Pressure Transducer
Model 420
DESCRIPTIONThe Model 420 DP two-wire low range differential pressure
transmitters utilize supply voltage of 9 Vdc to 32 Vdc to produce
a two-wire 4 mA to 20mA process loop output for differential
pressure ranges of 2 psid to 25 psid. A minimum full scale ac-
curacy of 0.5% is achieved. Stainless steel construction ensures
durability under harsh, industrial conditions and includes zero
and span adjustments. A variety of options are available with
the Model 420 including choice of pressure adaptors and pres-
sure ports.
FEATURES• 0.5% accuracy
• 2 psid to 25 psid range
• Stainless steel
• Intrinsically safe available (2N option only)4
• CE approved5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model 420
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges 2, 5, 10, 15, 25 psid
Accuracy ±0.5 % full scale
Linearity ±0.25 % full scale (typical)
Hysteresis ±0.13 % full scale (typical)
Non-repeatability ±0.07 % full scale (typical)
Output (standard) 4 mA to 20 mA
Line pressure 1500 psi
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating 18 °C to 82 °C [0 °F to 180 °F]
Temperature, compensated -1 °C to 54 °C [30 °F to 130 °F]
Temperature, effect, zero ±1.0 % full scale/100 °F
Temperature, effect, span ±1.0 % reading/100 °F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (calibration) 15 Vdc to 40 Vdc
Max. load resistance 500 ohm
Shunt calibration data Included
Elec. termination (std) PTIH-10-6P or equiv. (Hermetic stainless)
Mating conn. (not incl) PT06A-10-6S or equiv. (AA111)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Gas, liquid
Overload-safe 1500 psi either side
Pressure port 1/8-27 NPT female
Wetted parts material 316 stainless steel
Case material Stainless steel
RANGE CODES
Range Code Available ranges
AR 2 psid
AT 5 psid
AV 10 psid
BJ 15 psid
BL 25 psid
OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Pressure ranges (psid)
2, 5, 10, 15, 25
Temperature compensation
1b. 30 °F to 130 °F1a. 60 °F to 160 °F1c. 0 °F to 185 °F
Internal amplifiers
2k. 4 mA to 20 mA (two wire)
Internal amplifier enhancements
3d. Remote buffered shunt calibration
Pressure ports2 5h. 1/8-27 NPT female5c. 7/16-20 UNF female
Electrical termination
6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 250 °F)
6e. Integral cable: Teflon (-54 °C to 245 °C)
6f. Integral cable: PVC (-30 °C to 70 °C)
6g. Integral cable: Neoprene (-20 °C to 80 °C1)
6h. Integral cable: Silicone (-54 °C to 150 °C)
6i. Integral underwater cable (max. 80°C)1
6j. 1/2-14 conduit fit-ting with 1,5 m [5 ft] 4 conductor PVC cable
Special calibration
9a. 10 point (5 up/5 down) 20% increments @ 20 °C
9b. 20 point (10 up/10 down) 20% increments @ 20 °C
Wetted diaphragm
10a. 316 stainless steel
Increased line pressure
25a. 2000 psi line pressure25b. 3000 psi line pressure12a. 5000 psi line pressure
O ring seals 26c. Teflon
WIRING CODES
Connector Two-wire current 4 mA to 20 mA
A (+) supply
B no connection
C no connection
D (+) output (4 mA to 20 mA)
E Case ground
F no connection
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008708-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model 420 DP Low Range Two Wire Wet/Wet Differential Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
NOTES1. Availability varies according to range.2. Some pressure port options may require axial orientation.3. Range dependent; consult factory. Termination dependent; consult
factory.4. Internal amp and termination dependent; consult factory.
Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An available alternative is to specify 4 mA at negative full scale and 20 mA at positive full scale.
WARNINGPERSONAL INJURY
• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.
• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
TYPICAL SYSTEM DIAGRAM
MOUNTING DIMENSIONS AND CHARACTERISTICS
For reference only
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
DP Mid Range Two Wire Wet/Wet Differential Pressure Transducer
Model 420
DESCRIPTIONThe Model 420 DP two-wire mid range differential pressure
transmitters utilize supply voltage of 9 Vdc to 32 Vdc to produce
a two-wire 4 mA to 20mA process loop output for differential
pressure ranges of 50 psid to 750 psid. A minimum full scale ac-
curacy of 0.5% is achieved. Stainless steel construction ensures
durability under harsh, industrial conditions and includes zero
and span adjustments. A variety of options are available with
the Model 420 including choice of pressure adaptors and pres-
sure ports.
FEATURES• 0.5% accuracy
• 50 psid to 750 psid range
• Stainless steel
• Intrinsically safe available (2N option only)4
• CE approved5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model 420
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges 50, 75, 100, 150, 200, 300, 500, 750 psid
Accuracy ±0.5 % full scale
Linearity ±0.25 % full scale (typical)
Hysteresis ±0.13 % full scale (typical)
Non-repeatability ±0.07 % full scale (typical)
Output (standard) 4 mA to 20 mA
Line pressure 1500 psi
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating 18 °C to 82 °C [0 °F to 180 °F]
Temperature, compensated 16 °C to 71 °C [60 °F to 160 °F]
Temperature, effect, zero ±1.0 % full scale/ 38 °C [100 °F]
Temperature, effect, span ±1.0 % reading/ 38 °C [100 °F]
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (calibration) 15 Vdc to 40 Vdc
Maximum load resistance 500 ohm
Shunt calibration data Included
Elec. termination (std) PTIH-10-6P or equiv. (Hermetic stainless)
Mating conn. (not incl) PT06A-10-6S or equiv. (AA111)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Gas, liquid
Overload-safe 1500 psi either side
Pressure port 1/8-27 NPT female (2)
Wetted parts material 17-4 PH stainless steel
Case material Stainless steel
RANGE CODES
RangeCode
RANGE RangeCode
RANGE
BN 50 psid CL 200 psid
BP 75 psid CP 300 psid
BR 100 psid CR 500 psid
CJ 150 psid CT 750 psid
OPTION CODES
Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Pressure ranges (psid)
50, 75, 100, 150, 200, 300, 500, 750
Temperature compensation
1a. 60 °F to 160 °F1b. 30 °F to 130 °F
1c. 0 °F to 185 °F
Internal amplifiers 2k. 4 mA to 20 mA (two wire)
Internal amplifier enhancements
3d. Remote buffered shunt calibration
Pressure ports2 5h. 1/8-27 NPT female5c. 7/16-20 UNF female
Electrical termination
6a. Bendix PTIH-10-6P (or equiv.) 6 pin (250 °F)
6e. Integral cable: Teflon (-54 °C to 245 °C)
6f. Integral cable: PVC (-30 °C to 70 °C)
6g. Integral cable: Neoprene (-20 °C to 80 °C)1
6h. Integral cable: Silicone (-54 °C to 150 °C)
6i. Integral underwater cable (8 m [26 ft]) (max. 80 °C)1
6j. 1/2-14 conduit fitting with 1,5 m [5 ft] 4 conductor PVC cable
Special calibration
9a. 10 point (5 up/5 down) 20% increments @ 20 °C [68 °F]
9b. 20 point (10 up/10 down) 20% increments @ 20 °C [68 °F]
Wetted diaphragm
17-4 stainless steel
O-ring seals 26a. Metal26c. Teflon
WIRING CODES
Connector/ two-wire current/ 4 mA to 20 mA
A (+) supply
B No connection
C No connection
D (+) output (4 mA to 20 mA)
E Case ground
F No connection
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008709-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model 420 DP Mid Range Two Wire Wet/Wet Differential Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
NOTES1. Availability varies according to range.2. Some pressure port options may require axial orientation.3. Range dependent; consult factory. Termination dependent; consult
factory.4. Internal amp and termination dependent; consult factory. Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An available alternative is to specify 4 mA at negative full scale and 20 mA at positive full scale.
WARNINGPERSONAL INJURY
• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.
• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
TYPICAL SYSTEM DIAGRAM
1/8-27
MOUNTING DIMENSIONS AND CHARACTERISTICS
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
DP High Range Two Wire Wet/Wet Differential Pressure Transducer
Model 420
DESCRIPTIONThe Model 420 DP two-wire high range differential pressure
transmitters utilize supply voltage of 9 Vdc to 32 Vdc to produce
a two-wire 4 mA to 20mA process loop output for differential
pressure ranges of 2000 psid to 10000 psid. A minimum full
scale accuracy of 0.5% is achieved. Stainless steel construc-
tion ensures durability under harsh, industrial conditions and
includes zero and span adjustments. A variety of options are
available with the Model 420 including choice of pressure adap-
tors and pressure ports.
FEATURES• 0.5% accuracy
• 2000 psid to 10000 psid range
• Stainless steel
• Intrinsically safe available (2N option only)4
• CE approved5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model 420
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges 2000, 3000, 5000, 7500, 10000 psid
Accuracy ±0.5 % full scale
Linearity ±0.25 % full scale (typical)
Hysteresis ±0.13 % full scale (typical)
Non-repeatability ±0.07 % full scale (typical)
Output (standard) 4 mA to 20 mA
Line pressure 1500 psi
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating 18 °C to 82 °C [0 °F to 180 °F]
Temperature, compensated 16 °C to 71 °C [60 °F to 160 °F]
Temperature, effect, zero ±1.0 % full scale/38 °C [100 °F]
Temperature, effect, span ±1.0 % reading/38 °C [100 °F]
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (calibration) 15 Vdc to 40 Vdc
Max. load resistance 500 ohm
Shunt calibration data Included
Elec. termination (std) PTIH-10-6P or equiv. (Hermetic stainless)
Mating conn. (not incl) PT06A-10-6S or equiv. (AA111)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Gas, liquid
Overload-safe 50% over capacity
Pressure port 1/4-18 NPT female (2)
Wetted parts material 17-4 PH stainless steel
Case material Stainless steel
RANGE CODES
Range Code Available ranges
DL 2000 psid
DN 3000 psid
DR 5000 psid
DT 7500 psid
DV 10000 psid
OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Pressure ranges (psid)
2000, 3000, 5000, 7500, 10000
Temperature compensation
1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F
Internal amplifiers
2k. 4 mA to 20 mA (two wire)
Internal amplifier enhancements
3d. Remote buffered shunt calibration
Pressure ports 5h. 1/4-18 NPT female5c. 7/16- 20 UNF female
Electricaltermination
6a. Bendix PTIH-10-6P (or equivalent) 6 pin (max. 121 °C)
6e. Integral cable: Teflon (-54 °C to 245 °C)
6f. Integral cable: PVC (-30 °C to 70 °C)
6g. Integral cable: Neoprene (-20 °C to 80 °C)1
6h. Integral cable: Silicone (-54 °C to 150 °C)
6i. Integral underwater cable (8 m [26 ft]) (max. 80 °C)1
6j. 1/2-14 conduit fitting with 1,5 m [5 ft] 4 conductor PVC cable
Special calibra-tion
9a. 10 point (5 up/5 down) 20% increments @ 20 °C [68 °F]
9b. 20 point (10 up/10 down) 20% increments @ 20 °C [68 °F]
Wetted diaphragm
17-4 PH stainless steel
O-ring seals 26a. Metal
WIRING CODES
Connector Two-wire current 4 mA to 20 mA
A (+) supply
B no connection
C no connection
D (+) output (4 mA to 20 mA)
E Case ground
F no connection
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008710-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model 420 DP High Range Two Wire Wet/Wet Differential Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINGPERSONAL INJURY
• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.
• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
TYPICAL SYSTEM DIAGRAM
MOUNTING DIMENSIONS AND CHARACTERISTICS
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Subminiature Wet/Wet Differential Pressure Transducer
Model P-30-P
DESCRIPTIONThe Model P-30-P, wet/wet differential pressure transducer, is a
subminiature unit which is uniquely suited to aerospace, chemi-
cal or nuclear applications. Features include small size, bidirec-
tional overload protection, wide temperature compensation, and
high natural frequencies.
FEATURES• 0.3%accuracy
• 5psidto2000psid
• Highfrequency
• Lightweight
• Compactdesign
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model P-30-P
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges (psid) 5,10,15,25,50,75,100,150,200,300,500,750,1000,2000
Accuracy ±0.3%fullscale
Linearity ±0.2%fullscale(typical)
Hysteresis ±0.1%fullscale(typical)
Non-repeatability ±0.1%fullscale(typical)
Output (standard)
5psidto25psid 100mV(nominal)
50psidto2000psid 2mV/V(nominal)
Linepressure
5psidto25psid 250psi
50psidto2000psid 500psior2Xfullscale(whicheverishigher)upto2000psi
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54°Cto121°C[-65°Fto250°F]
Temperature, compensated 16°Cto71°C[60°Fto160°F]
Temperature effect, zero
5psidto25psid ±2.0%fullscale/100°F
50psidto2000psid ±1.0%reading/100°F
Temperature effect, span
5psidto25psid ±2.0%fullscale/100°F
50psidto2000psid ±1.0%reading/100°F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Straingagetype
5psidto25psid Bonded semiconductor
50psidto2000psid Bonded foil
Excitation (calibration) 10Vdc
Bridge resistance
5psidto25psid 500ohm
50psidto2000psid 350ohm
Shuntcalibrationdata Included
Elec. termination (std) Tefloncable1.5m[5ft]
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Gas, liquid
Overload-safe Max. line pressure either side
Pressure port 1/8-27NPTmale:7/16hex
Wetted parts material 17-4PHstainlesssteel
Casematerial Stainlesssteel
RANGE CODES
Range Code
Range Range Code
Range
AT 5psid CJ 150psid
AV 10psid CL 200psid
BJ 15psid CP 300 psid
BL 25psid CR 500psid
BN 50psid CT 750psid
BP 75psid CV 1000psid
BR 100psid DL 2000psid
OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Pressure ranges (psid)
5,10,15,25,50,75,100,150,200,300,500,750,1000,2000
Temperature compensation
1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F
1e.-20°Fto200°F1f.70°Fto250°F1g.0°Cto50°C
Internal amplifiers
2u.Unamplified,mV/Voutput
Pressure ports 5i.1/8-27NPTmale5d.7/16-20UNFmale(perMS33656-E4)
Electrical termination
6e.Integralcable:Teflon(-54°Cto245°C)6i.Integralunderwatercable(8m[26ft])(max.
80°C)1
WIRING CODES
Connector/unamplified
Red (+) excitation
Black (-) excitation
Green (-) output
White (+) output
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008711-1-ENIL50GLOMay2008Copyright©2008HoneywellInternationalInc.Allrightsreserved.
Model P-30-P Subminiature Wet/Wet Differential Pressure Transducer
Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]
WARNINGPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.
•Completeinstallation,operationandmaintenanceinformation is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
TYPICAL SYSTEM DIAGRAM
For reference only
2X
NOTES1.Availabilityvariesaccordingtorange. For long cable runs or electrically noisy environments an amplified sensor or locally mounted amplifier is often preferred.
MOUNTING DIMENSIONS AND CHARACTERISTICS
Range (psid) Order codes D mm [in] L mm [in]
5to25 BD311 28,7mm[1.13] 35,6mm[1.4]
50to500 BD312 28,7mm[1.13] 35,6mm[1.4]
750to2000 BD312 35,1mm[1.38] 40,6mm[1.6]
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Aerospace Pressure TransducersModel AS25D
DESCRIPTIONModel AS25D wet/wet differential pressure sensor features
welded stainless steel diaphragms on both ports. All units
are able to meet MIL-45208 and traceability requirements.
FEATURES• 0.3% accuracy
• Lightweight
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model AS25D
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges 15 psid to 2000 psid
Accuracy ±0.3 %
Non-linearity ±0.2 % full scale (typical)
Hysteresis ±0.1 % full scale (typical)
Output 2 mV/V nominal
Resolution Infinite
WIRINg CODES
Cable/unamplified
Red (+) excitation
Black (-) excitation
Green (-) output
White (+) output
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54 °C to 149 °C [-65 °F to 300 °F]
Temperature, compensated -54 °C to 121 °C [-65 °F to 250 °F]
Temperature, effect, zero 0.01 % full scale/ °F
Temperature, effect, span 0.01 % reading/ °F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Excitation (calibration) 10 Vdc
Bridge resistance 350 ohm
Electrical termination (std) Shielded cable
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Fluids compatible with 17-4 PH stainless steel
Pressure port 7/16-20 per MS33656-E4
Wetted parts material 17-4 PH stainless steel
Weight Consult factory
Case material Stainless steel
RANgE CODES
RangeCode
Ranges RangeCode
Ranges
BJ 15 psid CP 300 psid
BL 25 psid CR 500 psid
BN 50 psid CT 750 psid
BP 75 psid CV 1000 psid
BR 100 psid DJ 1500 psid
CJ 150 psid DL 2000 psid
CL 200 psid
TyPICAL SySTEM DIAgRAM
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008712-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model AS25D Aerospace Pressure Transducers
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURy
• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.
• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
Range (psid) ØD mm [in] L mm [in]
15, 25 28,7 mm [1.13] 35,6 mm [1.4]
50, 75, 100, 150, 200, 300, 500
28,7 mm [1.13] 35,6 mm [1.4]
750, 1000, 1500, 2000
35,1 mm [1.38] 40,6 mm [1.6]
MOUNTINg DIMENSIONS AND CHARACTERISTICS
2X-E4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
FM Approved Low Range Wet/Wet Differential Pressure Transmitter
Model 911FMD
DESCRIPTIONThe two-wire Factory Mutual Approved Model 911FM transmitter
has stainless steel diaphragms for use with liquid, gas, or vapors
in hazardous environments. These transducers are corrosion
and shock resistant, as well as reverse polarity protected. The
two-wire, 4 mA to 20 mA current output permits long cable runs
with a high signal-to-noise ratio. This model is constructed with
stainless steel, sealed hermetically.
FEATURES• 0.25%accuracy
• 2psidto25psid
• FactoryMutualapproved
• 4mAto20mAtwo-wire(standard)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model 911FMD
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges 2,5,10,15,25psid
Accuracy ±0.25%fullscale
Linearity ±0.15%fullscale(typical)
Hysteresis ±0.10%fullscale(typical)
Non-repeatability ±0.05%fullscale(typical)
Output(standard) 4 mA to 20 mA
Max. line pressure 1500psi
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating 18°Cto82°C[0°Fto180°F]
Temperature, compensated -1°Cto54°C[30°Fto130°F]
Temperature, effect, zero ±1.2%fullscale/100°F
Temperature, effect, span ±1.2%reading/100°F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Straingagetype Bonded foil
Excitation(calibration) 15Vdcto50Vdc
Shuntcalibrationdata Included
Elec.termination(std) 22 GA cable with case ground 609,6mm[2ft],1/2NPTto14NPT
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Gas, liquid
Overload-safe(eitherside) 1500psi
Pressure port 1/8-27NPTfemale
Wetted parts material 316stainlesssteel
Casematerial Stainlesssteel
RANGE CODES
Range Code Available ranges
AR 2 psid
AT 5psid
AV 10 psid
BJ 15psid
BL 25psid
OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Pressure ranges (psid)
2,5,10,15,25
Temperature compensation
1b.30°Fto130°F
Internal amplifiers
2k.4mAto20mA(two-wire)
Pressure ports 5h.1/8-27NPTfemale
Electrical termination
6j. 22 GA cable with case ground 609,6 mm [2ft],1/2NPTto14NPT
Special calibration
9a.10point(5up/5down)20%increments@20°C[68°F]
9b.20point(10up/10down)10%increments@20°C[68°F]
Wetted diaphragm
10a.316stainlesssteel
WIRING CODES
Cable/ two-wire current/ 4 mA to 20 mA
Red (+)supply
Black (+)output(4mAto20mA)
White Caseground
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008705-1-ENIL50GLOMay 2008Copyright©2008HoneywellInternationalInc.Allrightsreserved.
Model 911FMD FM Approved Low Range Wet/Wet Differential Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com
WARNINGPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.
•Completeinstallation,operationandmaintenanceinformation is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
TYPICAL SYSTEM DIAGRAM
MOUNTING DIMENSIONS AND CHARACTERISTICS
Mounting hole1/4-28 NPT x 5/16 in DP2 each
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
FM Approved Mid Range Wet/Wet Differential Pressure Transducer
Model 911FMD
DESCRIPTIONThe two-wire Factory Mutual Approved Model 911FM transmitter
has stainless steel diaphragms for use with liquid, gas, or vapors
in hazardous environments. These transducers are corrosion
and shock resistant, as well as reverse polarity protected. The
two-wire, 4 mA to 20 mA current output permits long cable runs
with a high signal-to-noise ratio. This model is constructed with
stainless steel, sealed hermetically.
FEATURES• 0.25%accuracy
• 50psidto750psid
• FactoryMutualapproved
• 4mAto20mAtwo-wire(standard)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model 911FMD
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges 50,75,100,150,200,300,500,750psid
Accuracy ±0.25%fullscale
Linearity ±0.15%fullscale(typical)
Hysteresis ±0.10%fullscale(typical)
Non-repeatability ±0.05%fullscale(typical)
Output(standard) 4 mA to 20 mA
Line pressure 1500psi
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating 18°Cto82°C[0°Fto180°F]
Temperature, compensated 16°Cto71°C[60°Fto160°F]
Temperature, effect, zero ±1.2%fullscale/38°C[100°F]
Temperature, effect, span ±1.2%reading/38°C[100°F]
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Straingagetype Bonded foil
Excitation(calibration) 15Vdcto50Vdc
Shuntcalibrationdata Included
Elec.termination(std) 22 GA cable with case ground 609,6 mm[2ft],1/2-14NPT
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Gas, liquid
Overload-safe(eitherside) 1500psi
Pressure port 1/8-27NPTfemale
Wetted parts material 17-4PHstainlesssteel
Casematerial Stainlesssteel
WIRINg CODES
CAbLE/ TWO-WIRE CURRENT/ 4 MA TO 20 MA
Red (+)supply
black (+)output(4mAto20mA)
White Caseground
RANgE CODES
RangeCode
Available ranges
RangeCode
Available ranges
bN 50psid CL 200 psid
bP 75psid CP 300psid
bR 100 psid CR 500psid
CJ 150psid CT 750psid
OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Pressure ranges (psid)
50,75,100,150,200,300,500,750
Temperature compensation
1b. 60 °F to 160 °F
Internal amplifiers
2k.4mAto20mA(two-wire)
Pressure ports 5h.1/8-27NPTfemale(2)
Electrical termination
6j. 22 GA cable with case ground 609, 6mm[2ft],1/2NPTto14NPT
Special calibration
9a.10point(5up/5down) 20%increments@20°C[68°F]
9b.20point(10up/10down) 10%increments@20°C[68°F]
Wetted diaphragm
17-4PHstainlesssteel
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008707-1-ENIL50GLOMay 2008Copyright©2008HoneywellInternationalInc.Allrightsreserved.
Model 911FMD FM Approved Mid Range Wet/Wet Differential Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.
•Completeinstallation,operationandmaintenanceinformation is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
MOUNTINg DIMENSIONS AND CHARACTERISTICS
TYPICAL SYSTEM DIAgRAM
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
FM Approved High Range Wet/Wet Differential Pressure Transducer
Model 911FMD
FEATURES• Factory Mutual approved
• 4 mA to 20 mA two-wire
POTENTIAL APPLICATIONS• Lorem ipsum dolor sit amet, consectetuer adipiscing elit.
• Mauris massa sem, porttitor id, suscipit sed, venenatis nec,
• Nunc ligula. Vestibulum fringilla fringilla sem. Pellentesque
sapien neque, ullamcorper sit amet, id, aliquet at, elit.
• Phasellus euismod pulvinar lectus. Suspendisse ultricies
dapibus tortor.
• Vivamus mattis.
• Curabitur suscipit, neque quis imperdiet adipi
DESCRIPTIONModel 911 FMD Low and Mid Range, Factory Mutual Approved
Wet/Wet Differential transducers are engineered for use in harsh
industrial applications. The two-wire, 4 mA to 20 mA current out-
put permits cable runs up to 10 miles long with a high signal to
noise ratio. This model is constructed with stainless steel, sealed
hermetically.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model 911FMD
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges (psid) 1000, 2000, 3000, 5000, 7500, 10000
Accuracy ±0.25 % full scale
Linearity ±0.15 % full scale (typical)
Hysteresis ±0.10 % full scale (typical)
Non-repeatability ±0.05 % full scale (typical)
Output (standard) 4 mA to 20 mA
Max. line pressure Full scale capacity +2000 psi
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating 18 °C to 82 °C [0 °F to 180 °F]
Temperature, compensated 16 °C to 71 °C [60 °F to 160 °F]
Temperature, effect, zero ±1.2 % full scale/ 38 °C [100 °F]
Temperature, effect, span ±1.2 % reading/ 38 °C [100 °F]
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (calibration) 15 Vdc to 50 Vdc
Shunt calibration data Included
Electrical termination (std) 22 GA cable with case ground
609,6 mm [2 ft], 1/2-14 NPT
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Liquid
Overload-safe (either side)
1000 to 3000 psid 100 % over capacity
5000 to 10000 psid 50 % over capacity
Pressure port 1/4-18 NPT female (2)
Wetted parts material 17-4 PH stainless steel
Case material Stainless steel
RANGE CODES
Range Code Available ranges
CV 1000 psid
DL 2000 psid
DN 3000 psid
DR 5000 psid
DT 7500 psid
DV 10000 psid
OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Pressure ranges (psid)
1000, 2000, 3000, 5000, 7500, 10000
Temperature compensation
1b. 60 °F to 160 °F
Internal amplifiers
2k. 4 mA to 20 mA (two-wire)
Pressure ports 5a. 1/4-18 NPT female (2)
Electrical termination
6j. 22 GA cable with case ground 609,6 mm [2 ft], 1/2 NPT to 14 NPT
Special calibration
9a. 10 point (5 up/5 down) 20% increments @ 20 °C [68 °F]
9b. 20 point (10 up/10 down) 10% increments @ 20 °C [68 °F]
Wetted diaphragm
17-4 PH stainless steel
WIRING CODES
CAbLE/ TWO-WIRE CURRENT/ 4 MA TO 20 MA
Red (+) supply
black (+) output (4 mA to 20 mA)
White Case ground
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008706-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model 911FMD FM Approved High Range Wet/Wet Differential Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINGPERSONAL INJURY
• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.
• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
For reference only
MOUNTING DIMENSIONS AND CHARACTERISTICS
TYPICAL SYSTEM DIAGRAM
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
High Line Wet/Wet Differential Pressure Transducer
Model HL-Z
DESCRIPTIONThe High Line Wet/Wet Differential Pressure Model HL-Z is de-
signed to accept extreme line pressures of up to 5000 psi.* This
unique design features standard bonded foil strain gages on
stainless steel. Liquid and gas differential pressures of 50 psid
to 7500 psid are measured within a 0.25 % to 0.50 % full scale
accuracy. Typical applications include flow measurement and
laboratory testing.
FEATURES• Linepressureto5000psi
• 0.25%accuracy
• Intrinsicallysafeavailable(2Noptiononly)10
• CEapproved11
POTENTIAL APPLICATIONS• Flowmeasurement
• Laboratorytesting
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model HL-Z
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges 50, 75, 100, 150, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500* psid
Accuracy ±0.25 % full scale
Linearity ±0.15%fullscale(typical)
Hysteresis ±0.10%fullscale(typical)
Non-repeatability ±0.05%fullscale(typical)
Output(standard) 2mV/V(nominal)
Line pressure 2500 psi**
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54°Cto121°C[-65°Fto250°F]
Temperature, compensated 15°Cto71°C[60°Fto160°F]
Temperature, effect, zero ±0.5%fullscale/100°F
Temperature, effect, span ±0.5%reading/100°F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Straingagetype Bonded foil
Excitation(calibration) 10 Vdc
Bridge resistance 350 ohm
Shuntcalibrationdata Included
Elec.termination(std) PTIH-10-6Porequivalent(hermeticstainless)
Matingconnector(notincl.) PT06A-10-6Sorequiv.(AA111)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Gas, liquid
Overload-safe
50 psid to 1500 psid 2000 psi
2000 psid to 7500 psid Fullscalecapacity+2000psi
Pressure port 1/4-18NPTfemale(2)
Wetted parts material 17-4 PH stainless steel
Casematerial Stainlesssteel
OPTION CODES
Pressure ranges (psid)
Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Pressure ranges (psid)
50, 75, 100, 150, 200, 300, 500, 750, 1000, 1500, 3000, 5000, 7500
Temperature compensation
1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F
1f.70°Fto250°F1i.-65°Fto250°F6
1j.0°Cto50°C1m.-25°Cto110°C
Internal amplifiers
2u.Unamplified,mV/Voutput
2b. 4 wire ±5 Vdc2c. 0 Vdc to 5 Vdc2t. 0 Vdc to 10 Vdc2j. 4 mA to 20 mA
(threewire)output
2k. 4 mA to 20 mA (twowire)output12
2n.(2N)4mAto20mA(twowire)intrinsically safe12
Internal amp enhancements
3a.Input/outputisolation8
3d. Remote buffered shunt calibration
Pressure ports 5 5a.1/4-18NPTfemale5c.7/16-20UNFfemale
Electrical termination
6a.BendixPTIH-10-6P(orequiv.) 6pin(max.250°F)
6b.MStypeconnec-tor to mate with MS3106-14S-6S(max.160°F)1
6e.Integralcable:Teflon(-54°Cto245°C)
6f.Integralcable:PVC(-30°Cto70°C)
6g.Integralcable:Neoprene(-20°Cto80°C)1
6h.Integralcable:Silicone(-54°Cto150°C)
6i.Integralunderwatercable(8m[26ft]) (max.80°C)1
6j.1/2-14conduitfittingwith1,5m[5ft]of4 conductorPVCcable
Shunt calibration 8a. Precision internal resistor 6
Special calibra-tion
9a.10point(5up/5down) 20%increments@20°C
9b.20point(10up/10down) 10%increments@20°C
Wetted diaphragm 17-4 PH stainless steel
Bridge type 11a.Squarebridge6
11b.Symmetricalbridge6
11c.Square&symmetricalbridge6
Zero and span adjustment
14b. Top access to pots7
14a.Noaccesstopots
Increased line pressure
25b. 3000 psi line pressure25c. 5000 psi line pressure
Interfaces 53e.Signaturecalibration6
53t.TEDSIEEE1451.4module9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell•SensingandControl3
High Line Wet/Wet Differential Pressure Transducer
iNTERNAL AMPLIFIERS
Amplifier specifications
Voltage output: Option 2b
Voltage output: Option 2c
Voltage output: Option 2t
Current three-wire: Option 2j
Current two-wire: Option 2k
Intrinsically safe amp: Option 2n (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V @ 5 mA
0 V to 10 V or ±10 V @ 5 mA
4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
Input power (voltage) ±15Vor26Vdcto 32 Vdc
11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc 9 Vdc to 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65mA 4 mA to 28 mA 4 mA to 24 mA
Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rej. 60db 60db 60db 60db 60db 60db
Operating temp. -20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F
Reverse voltage protection Yes Yes Yes Yes Yes Yes
Short cir. protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector (std)2
A(+)SupplyB Output commonCSupplyreturnD(+)OutputEShuntcal1FShuntcal2
A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2
A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2
A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2
A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection
A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection
Wiring code: cable2,3,4 R(+)SupplyBl Output commonGSupplyreturnW(+)OutputBShuntcal1BrShuntcal2
R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2
R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2
R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2
R(+)SupplyBl(+)OutputWCaseground
R(+)SupplyBl(+)OutputWCaseground
* Black and green wires are internally connected.**PinsBandCareinternallyconnected.***SeeHoneywell’sWebsiteforthemostup-to-dateinformationregardingIntrinsicallysafeapprovals,ref#008-0547-00.
MOUNTINg DIMENSIONS AND CHARACTERISTICS
Forreferenceonly
2X
TyPICAL SySTEM DIAgRAM
1/4-18
NOTE:Forlongcablerunsorelectronicallynoisyenvironments,anamplifiedsensororlocallymountedamplifierisoftenpreferred.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008715-1-ENIL50GLOMay 2008Copyright©2008HoneywellInternationalInc.Allrightsreserved.
Model HL-Z High Line Wet/Wet Differential Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as beingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedto otherwise by Honeywell in writing; please refer to your orderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
Whileweprovideapplicationassistancepersonally,throughourliterature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com
WARNINgPERSONAL INJURy
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.
•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
RANgE CODES
Range Code
Availableranges
Range Code
Availableranges
BN ±50 psid CT ±750 psid
BP ±75 psid CV ±1000 psid
BR ±100 psid DJ ±1500 psid
CJ ±150 psid DL ±2000 psid
CL ±200 psid DN ±3000 psid
CP ±300 psid DR ±5000 psid
CR ±500 psid DT ±7500 psid
NOTES1.Availabilityvariesaccordingtorange.2. Interconnectingshuntcal.1terminalwithshuntcal.2terminalpro-
vides50%(unamplifiedunits),75%(4mAto20mA3-wireunits)or80%(voltageamplifiedunitsoffullscaleoutputforquickcalibration.Shuntcalibrationcomesstandardwithinternalamplifieroptions2b,2c,2tand2j.)
3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White,G=Green.Colorspecifyingcableandnumberorletterspecifying connector.
4. Nomatingconnectornecessaryforcableoption.5. Somepressureportoptionsmayrequireaxialorientation.6. Onlyavailablewithunamplifiedoption2u.7. Onlyavailablewithamplifiedoptions.8. OnlyavailablewithVdcoutputoptions2b,2c.9. ConsultfactoryforTEDSavailabilitywithamplifiedmodels.10. Range dependent; consult factory. Termination dependent; consult
factory.11.Internalampandterminationdependent;consultfactory.12. 5000 ohm bridge required.
Note:Unlessotherwisespecifiedonorder,amplifiedunitswith4mAto20mAoutputwillprovide4mAat0psidand20mAatpositivefullscaleandtheunitwillnotoperateinthenegativedirection.Anavail-ablealternativeistospecify4mAatnegativefullscaleand20mAatpositivefullscale.Allampsadd2intoamplifierhousing.
*NotavailablewithFMapproval** On units > 200 psid the sum of full scale pressure must be <= 9500
psi, on units < 200 psid consult factory
Connector Unamplified
A, B (+)excitation
C, D (-)excitation
E (-)output
F (+)output
WIRINg CODES
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
High Line Wet/Wet Differential Pressure Transducer
Model HL-A-5
DESCRIPTIONThe High Line Wet/Wet Differential Pressure Model HL-A-5 is de-
signed to accept extreme line pressures of up to 5000 psi.* This
unique design features standard bonded foil strain gages on
stainless steel. Liquid and gas differential pressures of 50 psid
to 7500 psid are measured within a 0.50 % full scale accuracy.
A variety of standard options are available with the Model
HL-A-5 including the traditional removable pressure adaptors
for cleaning purposes, extended temperature ranges, alterna-
tive pressure ports, internal amplifiers options, and electrical
terminations.
FEATURES• 0.5 % accuracy
• Line pressure to 5000 psi
• mV/V (standard), 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc
to 10 Vdc output
• Intrinsically safe available (2N option only)10
• CE approved11
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model HL-A-5
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges 50, 75, 100, 150, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500* psid
Accuracy ±0.5 % full scale
Linearity ±0.25 % full scale (typical)
Hysteresis ±0.13 % full scale (typical)
Non-repeatability ±0.07 % full scale (typical)
Output (standard) 2 mV/V (nominal)
Line pressure 2500 psi**
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]
Temperature, effect, zero ±0.75 % full scale/100 °F
Temperature, effect, span ±1 % reading/100 °F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (calibration) 10 Vdc
Bridge resistance 350 ohm
Shunt calibration data Included
Elec. termination (std) PTIH-10-6P or equivalent (hermetic stainless)
Mating connector (not incl.) PT06A-10-6S or equiv. (AA111)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Gas, liquid
Overload-safe
50 psid to 1500 psid 2000 psi
2000 psid to 7500 psid Full scale capacity + 2000 psi
Pressure port 1/4-18 NPT female
Wetted parts material 17-4 PH stainless steel
Case material Stainless steel
OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Pressure ranges (psid)
50, 75, 100, 150, 200, 300, 500, 750, 1000, 1500, 3000, 5000, 7500
Temperature compensation
1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F
1f. 70 °F to 250 °F1i. -65 °F to 250 °F6
1j. 0 °C to 50 °C1m. -25 °C to 110 °C
Internal amplifiers
2u. Unamplified, mV/V output
2b. 4 wire ±5 Vdc2c. 0 Vdc to 5 Vdc2t. 0 Vdc to 10 Vdc2j. 4 mA to 20 mA
(three wire) output
2k. 4 mA to 20 mA (two wire) output12
2n. (2N) 4 mA to 20 mA (two wire) intrinsically safe12
Internal amp enhancements
3a. Input/output isolation8
3d. Remote buffered shunt calibration
Pressure ports 5 5a. 1/4-18 NPT female5c. 7/16-20 UNF female (per MS33656E4)
Electrical termination
6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 250 °F)
6b. MS type connector to mate with MS3106-14S-6S (max. 160 °F)1
6e. Integral cable: Teflon (-54 °C to 245 °C)
6f. Integral cable: PVC (-30 °C to 70 °C)
6g. Integral cable: Neoprene (-20 °C to 80 °C) 1
6h. Integral cable: Silicone (-54 °C to 150 °C)
6i. Integral underwater cable (8m [26 ft]) (max. 80°C)1
6j. 1/2-14 conduit fitting with 1,5 m [5 ft] of 4 conductor PVC cable
Shunt calibration 8a. Precision internal resistor 6
Special calibration
9a. 10 point (5 up/5 down) 20% increments @ 20 °C9b. 20 point (10 up/10 down) 10% increments
@ 20 °C
Wetted diaphragm
17-4 PH stainless steel
Bridge type 11a. Square bridge6
11b. Symmetrical bridge6
11c. Square & symmetrical bridge6
Zero and span adjustment
14b. Top access to pots7
14a. No access to pots
Increased line pressure
25b. 3000 psi line pressure25c. 5000 psi line pressure
Interfaces 53e. Signature calibration6
53t. TEDS IEEE 1451.4 module9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell • Sensing and Control 3
High Line Wet/Wet Differential Pressure Transducer
INTERNAL AMPLIFIERS
Voltage output: Option 2b
Voltage output: Option 2c
Voltage output: Option 2t
Current three-wire: Option 2j
Current two-wire: Option 2k
Intrinsically safe amp: Option 2n (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V @ 5 mA
0 V to 10 V or ±10 V @ 5 mA
4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
Input power (voltage) ±15 V or 26 Vdc to 32 Vdc
11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc 9 Vdc to 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db
Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse voltage protection Yes Yes Yes Yes Yes Yes
Short cir. protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector(std)2
A (+) SupplyB Output commonC Supply returnD (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB Output common**C Supply return **D (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection
A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection
Wiring code: cable2,3,4 R (+) SupplyBl Output commonG Supply returnW (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl (+) OutputW Case ground
R (+) SupplyBl (+) OutputW Case ground
* Black and green wires are internally connected.** Pins B and C are internally connected.*** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals, ref #008-0547-00.
TyPICAL SySTEM DIAgRAM
1/4-18
MOUNTINg DIMENSIONS AND CHARACTERISTICS
2X
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008716-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model HL-A-5 High Line Wet/Wet Differential Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
NOTES1. Availability varies according to range.2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal pro-
vides 50% (unamplified units), 75% (4 mA to 20 mA 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier options 2b, 2c, 2t and 2j.)
3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector.
4. No mating connector necessary for cable option.5. Some pressure port options may require axial orientation.6. Only available with unamplified option 2u.7. Only available with amplified options.8. Only available with Vdc output options 2b, 2c.9. Consult factory for TEDS availability with amplified models.10. Range dependent; consult factory. Termination dependent; consult
factory.11. Internal amp and termination dependent; consult factory.
Note: Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An avail-able alternative is to specify 4 mA at negative full scale and 20 mA at positive full scale. All amps add 2 in to amplifier housing.
* Not available with FM approval** On units > 200 psid the sum of full scale pressure must be <= 9500
psi, on units < 200 psid consult factory
WARNINgPERSONAL INJURy
• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.
• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
RANgE CODES
Range Code
Availableranges
Range Code
Availableranges
BN ±50 psid CT ±750 psid
BP ±75 psid CV ±1000 psid
BR ±100 psid DJ ±1500 psid
CJ ±150 psid DL ±2000 psid
CL ±200 psid DN ±3000 psid
CP ±300 psid DR ±5000 psid
CR ±500 psid DT* ±7500 psid
Connector Unamplified
A, B (+) excitation
C, D (-) excitation
E (-) output
F (+) output
WIRINg CODES
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Ultra Precision Wet/Wet Differential Pressure Transducer
Model TJE
DESCRIPTIONModel TJE Ultra Wet/Wet Differential is a bonded foil strain gage
transducers designed to accept fluid in both ports and measure
differential pressure ranges from 50 psid to 750 psid. Standard
features such as overload stops and stainless steel construction
provide unit durability in rugged industrial environments. Each is
bi-directional and achieves accuracies of 0.1 % full scale.
A variety of standard options are available with the Model TJE
Ultra including the traditional removable pressure adaptors for
cleaning purposes, extended temperature ranges, alternative
pressure ports, internal amplifiers options, and electrical termi-
nations.
FEATURES• 0.1% accuracy
• 50 psid to 750 psid
• mV/V (standard), 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc
to 10 Vdc output
• Intrinsically safe available (2N option only)10
• CE approved11
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model TJE
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges 50, 75, 100, 150, 200, 300, 500, 750 psid
Accuracy ±0.1 % full scale
Output (standard) 2 mV/V (nominal)
Line pressure 1500 psi
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]
Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]
Temperature, effect, zero ±0.25 % full scale/100 °F
Temperature, effect, span ±0.25 % reading/100 °F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strain gage type Bonded foil
Excitation (calibration) 10 Vdc
Excitation (acceptable) Up to 10 Vdc or ac
Insulation resistance 10000 mOhm @ 50 Vdc
Bridge resistance 350 ohm
Shunt calibration data Included
Elec. termination (std) PTIH-10-6P or equivalent (hermetic stain-less)
Mating connector (not incl.) PT06A-10-6S or equiv. (AA111)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Gas, liquid
Overload-safe 1500 psi
Pressure port 1/8-27 NPT female (2)
Dead volume 0.25 cu. in
Wetted parts material 17-4 PH stainless steel
Case material Stainless steel
RANGE CODES
Range Code Available ranges
BN ±50 psid
BP ±75 psid
BR ±100 psid
CJ ±150 psid
CL ±200 psid
CP ±300 psid
CR ±500 psid
CT ±750 psid
OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Pressure ranges (psid)
50, 75, 100, 150, 200, 300, 500, 750
Temperature compensation
1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F1f. 70 °F to 250 °F
1g. 70 °F to 325 °F6
1h. 70 °F to 400 °F6
1i. -65 °F to 250 °F6
1j. 0 °C to 50 °C1m. -25 °C to 110 °C
Internal amplifiers
2b. 4 wire ±5 Vdc2c. 0 Vdc to 5 Vdc2t. 0 Vdc to 10 Vdc2j. 4 mA to 20 mA
(3 wire) output2k. 4 mA to 20 mA
(2 wire) output12
2n. (2N) 4 mA to 20 mA (2 wire) intrin-sically safe12
2u. Unamplified, mV/V output
Internal amp enhancements
3a. Input/output isolation8
3d. Remote buffered shunt calibration
Pressure ports5 5c. 7/16-20 UNF female5h. 1/8-27 NPT female (2)
Electrical termination
6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 250 °F)
6b. MS type connector to mate with MS3106-14S-6S (max. 160 °F)1
6e. Integral cable: Teflon (-54 °C to 245 °C)
6f. Integral cable: PVC (-30 °C to 70 °C)
6g. Integral cable: Neoprene (-20 °C to 80 °C)
6h. Integral cable: Silicone (-54 °C to 150 °C)
6i. Integral underwater cable (8m [26 ft]) (max. 80°C)1
6j. 1/2-14 conduit fitting with 1,5 m [5 ft] of 4 conductor PVC cable
Shunt calibration 8a. Precision internal resistor7
Special calibration
9a. 10 point (5 up/5 down) 20% increments @ 20 °C9b. 20 point (10 up/10 down)
10% increments @ 20 °C
Wetted diaphragm
17-4 PH stainless steel10a. 316 stainless steel
Bridge type 11a. Square bridge6
11b. Symmetrical bridge6
11c. Square & symmetrical bridge6
Zero & span adjustment
14a. No access 14b. Top access6
O ring seals 26a. Metal26b. Vi-Ton26c. Teflon
Interfaces 53e. Signature calibration6
53t. TEDS IEEE 1451.4 module9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell • Sensing and Control 3
Ultra Precision Wet/Wet Differential Pressure Transducer
iNTERNAL AMPLIFIERS
Amplifier specifications
Voltage output: Option 2b
Voltage output: Option 2c
Voltage output: Option 2t
Current three-wire: Option 2j
Current two-wire: Option 2k
Intrinsically safe amp: Option 2n (2N)***
Output signal ±5 V 0 V to 5 V or ±5 V @ 5 mA
0 V to 10 V or ±10 V @ 5 mA
4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
Input power (voltage) ±15 V or 26 Vdc to 32 Vdc
11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc
9 Vdc to 28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db
Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F
Reverse voltage protection Yes Yes Yes Yes Yes Yes
Short cir. protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector (std)2
A (+) SupplyB Output commonC Supply returnD (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB Output common**C Supply return **D (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2
A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection
A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection
Wiring code: cable2,3,4 R (+) SupplyBl Output commonG Supply returnW (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2
R (+) SupplyBl (+) OutputW Case ground
R (+) SupplyBl (+) OutputW Case ground
* Black and green wires are internally connected.** Pins B and C are internally connected.*** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals, ref #008-0547-00.
MOUNTING DIMENSIONS AND CHARACTERISTICSTyPICAL SySTEM DIAGRAM
NOTE: For long cable runs or electronically noisy environments, an amplified sensor or locally mounted amplifier is often preferred.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008717-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model TJE Ultra Precision Wet/Wet Differential Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINGPERSONAL INJURy
• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.
• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
NOTES1. Availability varies according to range.2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal
provides 50% (unamplified units), 75% (4 mA to 20 mA 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with inter-nal amplifier options 2b, 2c, 2t and 2j.)
3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector.
4. No mating connector necessary for cable option.5. Some pressure port options may require axial orientation.6. Only available with unamplified option 2u.7. Only available with amplified options.8. Only available with Vdc output options 2b, 2c.9. Consult factory for TEDS availability with amplified models.10. Range dependent; consult factory. Termination dependent;
consult factory.11. Internal amp and termination dependent; consult factory.12. 5000 ohm bridge required
Note: Unless otherwise specified on order, amplified units with 4 mA to 20 mA output will provide 4 mA at 0 psid and 20 mA at positive full scale and the unit will not operate in the negative direction. An available alternative is to specify 4 mA at negative full scale and 20 mA at positive full scale. All amps add 2 in to housing.
Connector Unamplified
A, B (+) excitation
C, D (-) excitation
E (-) output
F (+) output
WIRING CODES
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com